3½ DIGIT LARGE DISPLAY DIGITAL MULTIMETER

THINK SAFETY
WITH TERMINAL BLOCKING SYSTEM THINK
An ISO 9001:2015 Company MODEL - KM 6030
FEATURES: GENERAL SPECIFICATIONS :
˜ Test lead jack mechanical protection function í Sensing : Average Sensing.
21 FUNCTIONS 32 RANGES
& full Range over-load protection function í Display : 3½ digit 1999 counts LCD display.
˜ Low power consumption CMOS double with automatic sign and Function annunciators.
integration, A/D transform integrated circuit í Digit height : 28mm
í Over range indication : Highest digit of
NEW
˜ Back light display
(1) or (-1) is displayed.
˜ Auto Zero Calibration
í Polarity : Automatic (-)negative polarity indication.
˜ Auto Polarity display í Low battery : The “ ” sign is displayed when the
˜ Low Battery & Over range indication. battery Voltage drops below the operating Voltage.
˜ Selected range displayed on LCD. í Measurement rate : 2.5 measurements
˜ Instant continuity Buzzer. per second , nominal.
˜ Recessed safety designed Input jacks í Operating Temperature : 0°C to 40°C; (32°F to 104°F).
í Storage Temperature : -10°C to 50°C; (14°F to 122°F).
˜ “ DATA HOLD” switch freezes reading.
í Auto Power Off : The meter will shut off
ACCESSORIES : automatically about 15 Minutes after power is ON
Test leads, User’s Manual, Battery, Carrying Case,
if the meter is not in use.
Protective Holster, Temperature Probe.
í Power : Single 9 V Battery.
OPTIONAL ACCESSORIES: í Dimension : 192 (L) x 88 (W) x 42 (H) mm
Current Clamp CA 300, Current Clamp Adaptor CA500, í Weight : Approx. 600gms. (including battery)
CA1000, CA2000, High Voltage Probe PD-28.

ELECTRICAL SPECIFICATIONS - KM 6030


Accuracy specifications at 23°C ± 5°C less than 75% R.H.
DC VOLTAGE
AC VOLTAGE
Range Resolution Accuracy
Range Resolution Accuracy
200 mV 100 mV
2 V 1 mV 2 V 1 mV
±(0.5%rdg + 3dgts) 20 V 10 mV ±(1.0%rdg + 5dgts)
20 V 10 mV
200 V 100 mV 200 V 100 mV

±(1.0%rdg + 5dgts) 750 V 1 V ±(1.2%rdg + 5dgts)


1000 V 1 V
Input Impedance : 10MW Input Impedance : 200mV : 1MW, Other ranges : 10MW
Overload Protection : 200mV is 250V DC or AC RMS. Frequency : 40Hz-400Hz.
All other ranges 1000VDC or AC rms. Overload protection : 200mV is 250VDC or AC RMS. All other
ranges is 1000V DC or AC RMS.
Display : Average Value (RMS of Sine Wave).
AC CURRENT
TRANSISTOR hFE PARAMETER
Range Resolution Accuracy DC CURRENT MEASUREMENT
2 mA 1 mA Range Resolution Accuracy Range Comment Measuring condition
±(1.2%rdg + 5dgts)
20 mA 10 mA 2 mA 1 mA
±(1.0%rdg + 3dgts) Can measure NPN or Basic polarity current
200 mA 100 mA ±(2.0%rdg + 5dgts) 20 mA 10 mA hFE PNP transistor hFE. abt 10m A,
20 A 10 mA ±(3.0%rdg + 10dgts) 200 mA 100 mA ±(1.5%rdg + 5dgts) Range : 0-1000 b Vce abt 2.8V.

Overload Protection : 0.2A/250V Fuse (No fuse on 20A range). 20 A 10 mA ±(2.0%rdg + 10dgts)
Max Input Current : 20A (above 10A for 15 sec. maximum). Overload Protection : 0.2A/250V Fuse (No fuse on 20A range).
Frequency : 40Hz - 400Hz. Max Input Current : 20A (above 10A for 15 sec. maximum). DIODE AND CONTINUITY MEASUREMENT
Display : Average value (RMS of Sine Wave). Measuring Voltage Drop : Full range is 200mV. Measuring Condition
Comment
CAPACITANCE RESISTANCE Display diode Forward DC Current
forward voltage about 1mA
Range Resolution Accuracy Range Resolution Accuracy 1mV Backward DC Voltage
2 nF 1 pF 200 W 0.1 W ±(1.0%rdg + 5dgts) about 2.8V
20 nF 10 pF 2 KW 1 W Beeper sounds if Open circuit Voltage
±(4.0%rdg + 3dgts)
200 nF 100 pF 20 KW 10 W - Continuity about 2.8V
±(1.0%rdg + 2dgts) Resistance
2 mF 1 nF 200 KW 100 W < 70W ± 20W.
200 mF 100 nF ±(5.0%rdg + 3dgts) 2 MW 1 KW
Overload Protection : 250V DC or AC RMS.
Testing frequency and voltage : around 400Hz 40mVrms. 20 MW 10 KW ±(1.0%rdg + 15dgts)
Overload Protection : Maximum 36V DC or AC RMS.
Voltage at Open Circuit : < 700mV (200MW range, open
circuit voltage around 3V). FREQUENCY
TEMPERATURE Voltage at Open Circuit : All ranges 250VDC or AC RMS. Range Resolution Accuracy
Range Resolution Accuracy At 200W range, the resistance value caused by short circuit
2 KHz 1 Hz ±2.0% rdg + 5 dgts
of test load should be deducted from the measured reading
-40°C~0°C ±(5.0%rdg + 5dgts)
during measuring. Overload Protection : 250V DC or AC rms.
0°C~400°C 1°C ±(1.0%rdg + 3dgts) Input Sensitivity : >200mV rms
400°C~1000°C ±(3.0%rdg + 4dgts)

All Specifications are subject to change without prior notice

®
Gmail : sales@kusam-meco.co.in Web.: www.kusamelectrical.com
An ISO 9001:2015 Company

Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2017 new arrival/KM 6030 new April 2017 with terminal blocking system.cdr