α-S250iA Mechanical specifications
Clamping unit
Clamping mechanism Double toggle
Tonnage [kN | tonf] 2500 | 250 (3000 | 300)
Maximum and minimum die height Doubleplaten [mm] 650-300 (750-300)
Maximum and minimum die height Singleplaten [mm] -
Clamping stroke [mm] 600
Locating ring diameter [mm] Ø 160
Tie bar spacing, H×V [mm] 710 × 635
Platen size, H×V [mm] 1030 × 960
Minimum mould size, H×V [mm] *1 420 × 385
Ejector stroke [mm] 200
Maximum ejector force [kN | tonf] 80 | 8.0
Injection unit
Screw diameter [mm] 32 36 40 44 48 52 56
Injection stroke [mm] 150 150 150 176 176 208 260
Max. injection volume [cm3] 121 153 188 268 318 442 640
Nozzle touch force [kN | tonf] 30 | 3.0
Max. Injection Speed mm/s *3 330
Max. injection pressure (high-pressure filling mode) [MPa] *2 *4 380 345 280 - - - -
Max. injection pressure [MPa] *2 280 280 260 220 190 160*7 140*7
Max. pack pressure [MPa] *2 280 280 260 220 190 160*7 140*7
Max. injection rate [cm3/s] *3 265 335 414 501 597 700 812
Max. screw rotation speed [min-1] 400
Machine weight [t] *5 ≈ 12.5
Screw and Barrel
Number of heater [Barrel] 3 4
Number of heater [Nozzle] 1
standard - not available ( ) with hardware and/or software option
Total heater wattage [kW] 12.0 13.0 14.9 15.9 17.9 20.2 23.5
*1) Smaller mould than this size may limit clamp force.
*2) The maximum injection pressure and maximum pack pressure is not melt pressure but injection unit output.
- The maximum injection pressure and maximum pack pressure is the maximum value can be set.
- The maximum injection pressure and maximum pack pressure might be limited depending on the moulding condition.
*3) Maximum injection rate and maximum injection speed is a theoretical value.
- Maximum injection rate and maximum injection speed can not be guaranteed when the injection pressure is
maximum.
*4) The maximum injection pressure setting at high pressure filling mode option.
- There is a limitation in injection time setting and pack time setting, when high pressure filling mode option is selected.
(Contact sales for detail)
- High pressure resistance barrel and nozzle are necessary, when high pressure filling option is selected.
(Contact sales for detail)
*5) The machine without option.
*6) The pressure conversion is 1MPa=10kgf/cm2.
*7) The moulding condition might be limited by the resin.(Contact sales for detail)
MDS-03993-EN Technical information subject to changes without prior notice. All rights reserved. ©2019 FANUC Europe Corporation
α-S250iA Dimensions
( P L AT E N S I Z E )
EJECTOR HOLE
(EXTENDED THRU
Mould HEIGHT)
OV E R AL L L EN GTH
OV E R A L L WI DT H
PLATEN SURFACE
( P L AT E N S I Z E )
OVE RA L L HE IGTH
NOZZLE CENTER
ADJUSTMENT
LEVELLER
ENTRANCE FOR
STROKE
VIEW FROM A POWER LINE
VIEW FROM B
M O V I N G P L AT E N
MOVING S TAT I O N A R Y
P L AT E N P L AT E N
( P L AT E N S I Z E )
ROBOT MOUNTING
S U R FA C E
THRU
ROBOT BASE HEIGHT
( P L AT E N S I Z E )
( T I E B A R S PAC I N G )
CLAMP Mould HEIGHT P LAT EN S UR FACE
STROKE STROKE
MAX. R O B O T M O U N T I N G S U R FA C E
( T I E B A R S PAC I N G )
E J E C TO R
STROKE ( N O E J E C T O R P I N I S S TA N D A R D )
( T I E B A R S PAC I N G )
S TAT I O N A R Y P L AT E N