0% found this document useful (0 votes)
135 views1 page

Three Phase 40 To 60 KW

This document provides technical specifications for three phase solar inverters with power ratings of 40 kW, 50 kW, and 60 kW. It includes details on efficiency, voltage ranges, current ratings, output power limits, protection features, and operating conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views1 page

Three Phase 40 To 60 KW

This document provides technical specifications for three phase solar inverters with power ratings of 40 kW, 50 kW, and 60 kW. It includes details on efficiency, voltage ranges, current ratings, output power limits, protection features, and operating conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Three phase 40 kw | 50 kw | 60 kw

TECHNICAL SPECIFICATIONS
MODEL PSIT-40K-SM6 PSIT-50K-SM8 PSIT-60K-SM8
Efficiency
Max. Efficiency 98.2% 98.2% 98.2%
European Efficiency 97.8% 97.8% 97.8%
Input(PV)
Max. Input Voltage 1100V
Max. PV configuration (STC) 150%
Rated Input Voltage 620V

SUITABLE FOR
Max. Input Current 40A+2*32A 40A+3*32A 40A+3*32A
Max. Short Circuit Current 50A+2*45A 50A+3*45A 50A+3*45A
Start Input Voltage 200V

COMMERCIAL & INDUSTRIAL MPPT Operating Voltage Range


Max. Number of PV Strings 2/2/2
180~1000V
2/2/2/2 2/2/2/2

ROOFTOP SOLAR
No. of MPPTs 3 4 4
Output(Grid)
40000W 50000W 60000W

PROJECTS
Rated AC Active Power
Max. AC Apparent Power 44500VA 55600VA 66700VA
Max. AC Active Power (PF=1) 44500W 55600W 66700W
Max. AC Output Current 67.5A 84.3A 92A
Rated AC Voltage 380/400/415V, 3L/N/PE,3L/PE
AC Voltage Range� 322V-520V
Rated Grid Frequency 50Hz/60Hz
Grid Frequency Range� 45~55Hz/55~65Hz

Three phase THDI


DC Current Injection
3%(Rated Power)
<0.5%In
PSIT-40K-SM6 Power Factor 0.8LD~0.8LG

PSIT-50K-SM8 Protection
DC switch YES
PSIT-60K-SM8 Anti-islanding protection YES
AC overcurrent protection YES
AC short circuit protection YES
DC reverse protection YES
Surge Arrester DC Type II / AC Type II

Leading
Insulation detection YES
Leakage current protection YES
Features YEARS
WARRANTY
General
Topology Transformer-less
IP Rating IP66
Night Self Consumption <1W(standard)
• Maximum Efficiency 98.2% • Smart I-V Curve Diagnosis Cooling Fan cooling
Operating Temperature Range -250C-600C
• Wide Voltage Range • Fuse free design to avoid hazard
Relative Humidity Range 0-100%
• Supports 50% DC overload, • Type II SPD for both DC and A C side Max. Operating Altitude 4000m
Noise(typical) <45dB <45dB <55dB
• 3/4 MPPT design with precise MPPT algorithm • Integrated DC disconnect switches
Dimensions (W*H*D) 635mm*530mm*224mm 635mm*530mm*233mm
• THDi < 3%, • RS-485,Wi-Fi / GPRS monitoring interface Weight 41.5kg 42kg 42 kg
HMI & COM
• IP66 Enclosure • Support "Y" type connection in DC side
Display Wireless & APP+LED, LCD
• Intelligent Fan Cooling • Supports aluminium wire access to reduce cost Communication Wi-Fi / RS485 & GPRS (Optional)

• Intelligent string monitoring • Free remote monitoring on Web Portal and Mobile App Certification
Grid Connection IEC 61727

Anti-Islanding Protection IEC 62116


Environmental Testing IEC 60068-2 (1-2-14-30)

Safety IEC 62109-1, IEC 62109-2

EMC IEC 61000


Efficiency Measurement IEC 61683
Warranty 7 Years
Note :
①②The range of output voltage and frequency may vary depending upon different grid codes.
Specifications are subject to change without advance notice.
09