0% found this document useful (0 votes)
169 views3 pages

GE SWRO Series

This document provides specifications for seawater desalination machines that can desalinate seawater with a salt concentration of 45,000 ppm and produce 100-300 gallons per minute of desalinated water. It details the standard and premium features, operating parameters, materials of construction, instrumentation, models, and installation requirements.

Uploaded by

Muhammad Hassan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views3 pages

GE SWRO Series

This document provides specifications for seawater desalination machines that can desalinate seawater with a salt concentration of 45,000 ppm and produce 100-300 gallons per minute of desalinated water. It details the standard and premium features, operating parameters, materials of construction, instrumentation, models, and installation requirements.

Uploaded by

Muhammad Hassan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Fact Sheet

SWRO Series 60 Hz
Seawater Desalination Machines
45,000 ppm NaCl, 100-300 gpm (22.7-68.1 m3/hr)

Basic Features (BAS) Premium Features (PRE)


• GE Fanuc Quick Panel 6-inch color display. • GE Fanuc QuickPanel 12-inch color display.
Primarily text operating screens, Touchscreen Text and pictorial operating screens. Touch-
controls. screen controls.
• GE Fanuc Micro VersaMax processor • GE Fanuc VersaMax processor
• 4-20 mA instruments displayed on instrument • 4-20 mA instruments on touchscreen
center • Primary and final pressure transmitters
• Variable frequency drive (VFD) for high pres- • Variable frequency drive (VFD) for high pres-
sure pump sure pump
• Motor starter for boost pump • Motor starter for boost pump
• Stand alone master control enclosure, skid • Automated valves and control for feed flush
mounted local control enclosure with terminal upon shut down
strips
• Stand alone master control enclosure, local
• Membrane/energy recovery device control enclosure with remote I/O
(ERD)/boost pump and pump/prefilter located
on separate skids • Membrane/energy recovery device
(ERD)/boost pump and pump/prefilter located
on separate skids

Find a contact near you by Global Headquarters Americas Europe/Middle East/Africa Asia/Pacific
visiting ge.com/water or Trevose, PA Watertown, MA Heverlee, Belgium Shanghai, China
e-mailing custhelp@ge.com. +1-215-355-3300 +1-617-926-2500 +32-16-40-20-00 +86 (0) 411-8366-6489

©2008, General Electric Company. All rights reserved.


*Trademark of General Electric Company; may be registered in one or more countries. FS1019EN Apr-08
Operating Parameters Materials of Construction
Design Feed TDS 45,000 ppm NaCl Frame Painted Carbon Steel
Maximum Recovery 35% Cartridge Filter RO.Zs 05-40, 5-micron nomi-
nal
Nominal Rejection 95-98%
Cartridge Filter Housing GRP (glass reinforced plastic)
Operating Temperature 35 to 85ºF (1.6 to
29.4ºC) Membrane Elements GE SW-RO-400-HR-WT
Minimum Inlet Pressure 30 psig (2 Bar) Membrane Housing FRP
Design Temperature 77ºF (25ºC) Low Pressure Pipe Schedule 80 PVC
High Pressure Pipe Duplex 2205
Instrumentation Enclosures NEMA 4
Flow Meters........................Permeate, concentrate,
low pressure (LP) ERD inlet, Options Available
high pressure (HP) ERD • Allen Bradley control system
outlet
• Multi-Media filters
Conductivity.......................Permeate
• Clean-in-Place (CIP) units
pH ...........................................Feed
• Chemical feed systems
Pressure...............................Pre-filter, post-filter, pri-
mary, final, permeate, con- • Transfer pumps and storage tanks
centrate, LP ERD inlet, LP
ERD outlet, HP ERD inlet, Documentation Included
HP ERD outlet (PRE Feature • Operation and maintenance manual
= Primary, Final transmit-
• Control narrative
ter)
• Drawings: piping and instrumentation, electri-
Pressure Switches...........Feed, permeate, concen-
cal and general dimensional
trate, primary
Instrument Center ..........Thornton 770 MAX

SWRO Models
MODEL SWRO-42 SWRO-63 SWRO-84 SWRO-126
Permeate rate: 144k gpd 216k gpd 288k gpd 432k gpd
100 gpm (22.7 m3/hr) 150 gpm (34.1 m3/hr) 200 gpm (45.4 m3/hr) 300 gpm (68.1 m3/hr)
Concentrate Rate: 186 gpm (42.2 m3/hr) 279 gpm (63.4 m3/hr) 371 gpm (84.3 m3/hr) 557 gpm (126.5 m3/hr)
Feed Rate: 286 gpm (65.0 m3/hr) 429 gpm (97.4 m3/hr) 571 gpm (129.7 m3/hr) 857 gpm (194.6 m3/hr)

Pumps and Motors


Manufacturer: Fedco Fedco Fedco Fedco
Quantity: 1 1 1 1
HP Pump HP and Type: 100 Hp (75 kW) TEFC 150 Hp (110 kW) TEFC 200 Hp (150 kW) TEFC 250 Hp (186 kW) TEFC
Boost PumpHP and Type: 10 Hp (7.5 kW) TEFC 20 Hp (15 kW) TEFC 20 Hp (14.9 kW) TEFC 40 Hp (29.8 kW) TEFC

Energy Recovery Booster


Model: PX-220 PX-180 PX-220 PX-220
Manufacturer: ERI ERI ERI ERI
Quantity: 1 2 2 3
Design Flow Rate: 180 gpm (40.9 m3/hr) 135 gpm (30.7 m3/hr) 180 gpm (40.9 m3/hr) 180 gpm (40.9 m3/hr)

Membrane Elements and Housings


Membranes Quantity: 42 63 84 126
Memb. Housing Style: 7 element long, 4 port 7 element long, 4 port 7 element long, 4 port 7 element long, 4 port
Banking Arrangement: 6, parallel 9, parallel 12, parallel 18, parallel

Page 2 FS1019EN Apr-08


MODEL SWRO-42 SWRO-63 SWRO-84 SWRO-126
Cartridge Filtration
Cartridge Filter: RO.Zs05-40XK RO.Zs05-40XK RO.Zs05-40XK RO.Zs05-40XK
Filter Length: 40” (102 cm) 40” (102 cm) 40” (102 cm) 40” (106 cm)
Filter Quantity: 22 per change out 54 per change out 54 per change out 108 per change out

Installation and Utility Requirements


Inlet: 4.0” flange 6.0” flange 6.0” flange 8.0” flange
Permeate: 3.0” flange 3.0” flange 3.0” flange 4.0” flange
Concentrate: 3.0” flange 4.0” flange 6.0” flange 6.0” flange
Inlet Water Pressure: 30 psig, minimum 30 psig, minimum 30 psig, minimum 30 psig, minimum
Air Pressure: 100 psig, oil-free 100 psig, oil-free 100 psig, oil-free 100 psig, oil-free
Drain to be Sized for: 286 gpm (64.9 m3/hr) 455 gpm (103.3 m3/hr) 606 gpm (137.6 m3/hr) 909 gpm (206.4 m3/hr)
Power: 230/460 VAC, 3-phase, 60Hz 230/460 VAC, 3-phase, 60Hz 230/460 VAC, 3-phase, 60Hz 230/460 VAC, 3-phase, 60Hz
Control Circuit: 120 VAC, 1-phase, 60Hz 120 VAC, 1-phase, 60Hz 120 VAC, 1-phase, 60Hz 120 VAC, 1-phase, 60Hz

SWRO Skid
Membrane/ERD Skid
Height: 87” (221 cm) 87” (221 cm) 87” (221 cm) 87” (221 cm)
Width: 77” (196 cm) 77” (196 cm) 77” (196 cm) 90” (229 cm)
Depth: 324” (823 cm) 324” (823 cm) 324” (823 cm) 324” (823 cm)
Weight Estimate for
Shipping Purposes: 8,215 lb (3,725 kg) 10,055lb (4,560 kg) 12,260 lb (5,560 kg) 15,410 lb (6.990 kg)

Pump/Prefilter Skid 101” (257cm) 101” (257cm) 101” (257cm) 101” (257cm)
Height: 77” (196 cm) 77” (196 cm) 77” (196 cm) 77” (196 cm)
Width: 210” (533 cm) 210” (533 cm) 210” (533 cm) 210” (533 cm)
Depth:
Weight Estimate for 4,895 lb (2,220 kg) 5,885 lb (2,670 kg) 6,270 lb (2,845 kg) 7,095 lb (3,220 kg)
Shipping Purposes: 1,680 lb (760 kg) 2,520 lb (1,140 kg) 3,360 lb (1,525 kg) 5,040 lb (2,285 kg)
Membranes:

Page 3 FS1019EN Apr-08