0% found this document useful (0 votes)
60 views16 pages

Брошюра SonoScape S11

Uploaded by

kutmanali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views16 pages

Брошюра SonoScape S11

Uploaded by

kutmanali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Specifications for S11 High-Performance Color S ystem

SonoScape
THE PIONEER OF COLOR DOPPLER ULTRASOUND IN CHINA
Product Overview
Specifications for S11 High-Performance Color System

General Specification  PW Mode

The high performances of the SonoScape  THI Mode

S11 stem from the advanced ultrasound  Cardiac Package


Doppler imaging technologies that include  Gynecology Package
full digital beam-former, wide dynamic  Urology Package
range, multi-beam processing, etc.  Small Part Package

The ergonomic user-friendly design enables  Vascular Package


user to customize the system according to  Orthopedic Package
the specific application needs, and the  Compound Imaging
graphic exam icon assure you familiar with  Trapezoid Imaging
the system in few minutes.  ECG Module

 Dop Auto Trace

2. Advanced Technologies  IMT Function


 PC platform  Dicom 3.0
 Full Digital Beam Processing  Internal Workstation
 Compound Imaging

 Tissue Harmonic Imaging 4. Optional Functions


 Panoramic Imaging  μ-scan
 Trapezoid Imaging  4D Imaging
 4D Imaging  Panoramic Imaging
 Dicom 3.0  Anatomic M Mode
 Intelligent Upgrade  Color M Mode
 Graphic Exam Icon  CW Mode
 Remote Maintenance  Triplex Mode

3. Standard Configuration 5. Optional Components


 B Mode  UPS Power
 Multi-B Mode  Biopsy Guide
 M Mode  Color Ink-jet Printer
 Color Mode  B/W Video Printer
 DPI Mode  Foot Switch

page of 14
Specifications for S11 High-Performance Color System

9. Operating Modes
6. Sweep Width/Angle  B-Mode

 Linear Array: Maximum 46mm  M-Mode

 Convex Array: ≥70°  THI-Mode

 Phased Array: ≥90°  Color Flow Mode(CFM)

 Micro convex Array: ≥135°  Doppler Power Imaging(DPI)


 4D probe: 70°
 PW Mode

 CW Mode(optional)
7. Scanning Methods  Panoramic Imaging(optional)
 Electronic Convex Sector
 4D Imaging(optional)
 Electronic Linear
 Steer M-Mode(optional)
 Electronic Phased Array Sector
 Color M Mode(optional)
 4D Automatic Scanning

 Electronic Endocavity
10. Display Modes
 B、Dual B、4B
 B+Color、Dual B+Color
8. Applications
 B+DPI、Dual B+DPI
 Small Parts(Thyroid, Brest, Testicles
and  M、B+M、Dual B+M
 B+PW、Dual B+PW
Superficial)
 B+color+PW
 Abdominal(Liver, Spleen, Kidney,
 B+DPI+PW
Pancreas)
 B+CW、Dual B+CW(optional)
 Vascular(Carotid, Peripheral vessel)
 B+color+CW(optional)
 Cardiology
 B+DPI+CW(optional)
 Obstetrical(Uterus, Appendages, Fetus)
 B+ Color M (optional)
 Gynecological
 B+ Anatomic M(optional)
 Urological
 B+ Multi-M(optional)
 Musculoskeletal
 Panoramic Imaging(optional)
 Craniocerebral
 Trapezoid Imaging
 Emergency(optional)
 Compound Imaging
 ICU(optional)
 4D Imaging(optional)
 Anesthesia (optional)

page of 14
Specifications for S11 High-Performance Color System

 Storage Mode:depending on the

11. System Menu Setting frames


 Storage Region:Full Screen,
 System Setting
Imaging Area
 General Setting
 Save to USB
 Hospital Name
 Peripheral Equipments
 Language Setting
 Clip Format:NTSC、PAL
 English
 Internet setting
 Simple Chinese
 IP Adress
 Spanish(optional)
 Subnet Mask
 Russian(Optional)
 Default Gateway
 French(Optional)
 DNS Service
 Italian(Optional)
 Local DICOM AE Title
 German(Optional)
 Printer Setting
 Turkish(Optional)
 Annotation Setting
 Automatic Response to Freeze
 Annotation Library Setting
 Trackball Sensitive  Display Language:Current
 Set Time/ Date Language, English
 Letter form  Self-defined Entry
 Audio Volume  Body Mark Setting
 Display  Body Mark Library Setting
 TGC Curve  Default Display Position
 Patient Information  Measurement Setting
 Clipboard Automatic Open to  General Setting
Freeze
 Unit:Metric, British
 Parameters Setting
 Cardiac Cycle
 B Mode  UA Result:Last, Minimum,
 M Mode Maximum, Average

 Color Mode  Define Quick Key(Obstetric, Cardiac)

 DPI Mode  Calculation Menu Setting

 PW Mode  2D Mode

 CW Mode

 Storage
page of 14
Specifications for S11 High-Performance Color System

 Distance  BSA: Eastern, Western


 Trace  Obstetric Measurement Method
 Ellipse  EFW Method
 Angle  Report Setting
 Volume  Report Logo
 Ratio  Title, Font Size
 Vascular  Display Items
 Obstetric  DICOM Setting
 Gynecological  DICOM Image Storage
 Cardiac  DICOM Storage Commitment
 Small Part  Worklist
 Urologic  MPPS
 Orthopedic  DICOM Printing
 M Mode  System Information
 Time  Software Version
 Distance  Restore to Factory Defaults
 Slope  System Upgrade:USB Upgrade,
Remote Network Upgrade
 Ratio

 Heart Rate
12. Standard Features
 Left Ventricle
 Frame Rate: Max 800frames/sec or
 Mitral Valve
more(configuration dependent)
 Aortic Valve
 Display Gray Scale: 256 Levels
 PW Mode
 Probe Elements:Up to 128
 Flow Velocity

 Time
13. B Mode
 Heart Rate
 Focus: Up to 15, Focus span adjustable
 Manual Trace
 Line Density: High/ Med
 Vascular
 Dynamic Range: 20-320 (probe
 Obstetric
dependent)
 Cardiac
 GSC(Gray Scale Curve): 21 steps
 Measurement Method Setting

page of 14
Specifications for S11 High-Performance Color System

selectable  Left/Right: ON/OFF


 Gain: 0-255 adjustable  Resolution: 6 kinds
 Left and Right Inversion

 Up and Down Inversion 15. M Mode


 TGC(Time Gain Control): 8 slide controls  Chroma: 8 kinds selectable
 Depth: Max 33.3cm(probe dependable)  Enhancement: 8 kinds selectable
 Frequency Range: 5 steps  Video Invert: ON/OFF(optional)
 Persist: 8 steps selectable  Sweep Speed: 2, 4, 6, 8 sec/plane
 Chroma: 9 steps selectable  Steer M:3 sample lines, Display frame
rate(optional)
 SEC.WIDTH: adjustable
 Display Format:
 Biopsy Guide: (optional)
H1/1、H1/2、H2/1、V1/1、
 Biopsy Angle adjustable
V1/2
 Biopsy Offset adjustable
 Power:1%-100% adjustable,5 steps
each 16. Spectral Doppler
 B Steer Mode(Linear, optional)  Chroma: 8 kinds selectable

 Spectrum Inversion

14. Color Flow Mode  PRF:0.7~5.7kHz(PW)

 Frame Rate:≥50 frames/sec  PRF:1-48KHz(CW)


 Baseline Shift:15 steps
 Color Area Size and Position: adjustable
 Video Invert: ON/OFF(optional)
 Single auto focus while color ROI
 Filter: 25-750 adjustable
movement
 2D-Refresh(optional)
 Steer Angle:0, ±12, ±16, ±20
 Doppler Methods
degree adjustable
 PW(pulsed wave) Doppler
 Persistence:8 steps selectable
 CW(continuous wave) Doppler
 Frequency Range: 5 steps
 Doppler Envelope: manual trace, auto
 PRF:0.5-5.7kHz(probe dependent)
 Color Baseline:±15 steps trace, real time trace, freeze trace

 Filter: 5-750 adjustable  Max Velocity Range:


 Color/Power Map:15 kinds  0.0004-40.9 m/s(PW)
 B Reject:0-255  0.0013-49.1 m/s(CW)

 Flow Invert: ON/OFF(optional)  Dynamic Range: 10 steps selectable

page of 14
Specifications for S11 High-Performance Color System

 Frequency Range: 5 steps 19. Storage Media


 θ Angle Correction: 0-80°  Hard Disk memory capacity: 320 G
 Sample Volume Size for PW Doppler: 1  Storage media: USB Drive
-20 mm  USB Drive
 Sweep Speed: 2, 4, 6, 8 sec/plane  DVD RW
 Steer Angle: 0、±12、±16、±20,7
kinds
 Display Format: 20. Storage of Images and Cine
H1/1、H1/2、H2/1、V1/1、
 Cine loop: 999 frames or more
V1/2
 Cine loop time:99 seconds or more

 Archived image can be viewed on PC


17. 4D Mode (optional)
 Cropboard function: in Freeze Mode
 Render Mode: Vol、MaxIP
 Cine play back mode for Dop.
 Auto Rotate (45、90、180、270、360
degrees adjustable )

 Zoom Function 21. DICOM Network Communication

 Rotate Function  Structural SR):


Repor(t ABD、OB、GYN、

 Color Map:4 kinds Cardiac、 Vascular、 Urology、 Small


 Image Quality: high、med、low Parts、 PED、MSK、 Nerve、
Orthopedics
 4D Stabilization
 DICOM Image Storage Format: RLE,
 Save images
JPEG
 Print
 DICOM Remote Storage

 DICOM ECHO
18. ECG Module (optional)  DICOM Storage Commitment
 ECG, Pulse Wave
 DICOM Work list
 ECG Lead-three lead system
 DICOM MPPS
 ECG Gain: adjustable
 DICOM Print
 ECG Position: adjustable
 DICOM Media Storage
 ECG Invert: on/off

 R Trigger: on/off
22. Data Communication
 Trigger Delay: adjustable
 All patient data in this ultrasound unit can
 Frame Count: adjustable
be outputted to Flash Disk and DICOM, in

page of 14
Specifications for S11 High-Performance Color System
file folder of patient, examination mode,

page of 14
Specifications for S11 High-Performance Color System

image and report. 27. Display Screen


 15-inch High-Resolution Color LCD

23. Pre-set Function monitor


 Users can optimize the Pre-set by

changing different parameters for different 28. Safety Standard


probes and examination.  Meet with IEC60601-1, Class I,BF

international standard

24. Patient Data Management


 Patient Registration: Name, ID, Gender, 29. Environmental Requirements

Date of Birth, Height, Weight, Blood In operation

Pressure, Body Surface Area, Heart Rate,  Temperature:+10 to +40 degrees C

LMP, GA, Doctor’s comment  Relative Humidity: 30% to 75%

 Retrieve the patient from Worklist (non condensing)

 Patient Data, report, images can be  Atmospheric pressure: 700 to 1060hPa

searched, retrieved, DICOM sending, In Storage/Transportation

Send to Report, Print and so on  Temperature: -20 to +55 degrees C

 Relative humidity: 20%- 90%

25. Annotation and Body Mark (non condensing)

 Body Mark: more than 100 kinds  Atmospheric Pressure: 700 to 1060hPa

 Divided into different applications Power Supply

 User-definable annotation  100/220 Volts AC, 3.15Amps

 Annotation can be revised, moved, edited  Frequency: 50/60HZ

and deleted

 Body mark can be moved, while the 30. Optional Probe

probe mark can be moved and rotated  Linear Probe(Vascular, Small Parts)

 Arrow can be rotated and the size could →L741 (5-15 MHZ)

be changed  Linear Probe(Vascular, Small Parts)

→10L1 (6-12 MHZ)

26. Probe Connectors  Linear Probe(Intraoperative)

 Active Connectors: 3 connectors →10I2 (4.5-15 MHZ)

 Curved Probe(Abdomen, OB/GYN)

page of 14
Specifications for S11 High-Performance Color System

→C311 (3.2-6 MHZ) →Distance

 Curved Probe(Abdomen, OB/GYN) →Time Ratio/Distance Ratio

→C344 (2-6 MHZ)

 Curved Probe(Abdomen, OB/GYN) On Spectral Doppler

→C354 (2-6 MHZ) →Time

 Curved Probe(Abdomen, OB/GYN) →Heart Rate

→C611 (4-10 MHZ) → Velocity

 Micro-curved Probe(Transvaginal) →Acceleration

→6V1 (3.9-11 MHZ) →Resistance Index

 Endocavity Probe →Pulse Index

→EC9-5 (3.9-11 MHZ) →PV (Peak Velocity)

 Volumetric Probe (4D) →PG (Pressure gradient)

→VC6-2 (2-6 MHZ) →Auto Trace

 Phased Array Probe(Cardiology) →Manual trace

→2P1 (2.8-5 MHZ) →Mean Flow Velocity

 Phased Array Probe(Cardiology) →End Diastolic Velocity

→5P1 (4.2-8MHZ) →Pressure Half Time

31. Measurements/Calculations  Obstetrical/ Gynecological

General Measurements & Calculations


Measurements/Calculations
B Mode
On B-Mode

→Distance(real time、freeze) →GS (Gestational Sac diameter)

→Area and circumference (Trace, →CRL (Crown Rump Length)


Ellipse)
→BPD (Biparietal Diameter)
(real time、freeze)
→HC (Head Circumference)
→Volume (L×W×H, Area×L)
→AC (Abdominal Circumference)
→Angle
→FL (Femur Length)
On M-Mode
→CER (Cerebellum)
→Velocity
→OFD (Occipitofrontal Diameter)
→Time
→Fibula (Fibula Length)
→Heart rate
→Foot (Foot Length)
→Slope
page of 14
Specifications for S11 High-Performance Color System

→AA (Abdominal Area) →EFA (Estimated Fetal Age)


→APAD (Anteroposterior Abdominal →EDD (Estimated Date of Delivery)
Diameter) →EFW (Estimated Fetal Weight)
→HA (Head Area) →AUA (Average Ultrasound Age)
→Humerus (Humerus Length) →GA (Gestational Age)
→Kidney (Kidney Length) PW Mode
→APTD (Anteroposterior Trunk Diameter) →Umb A (Umbilical Artery)
→OOD (Outer Orbital Diameter) →MCA (Middle Cerebral Artery)
→Radius (Radius Length) →Rt Uterin A (Right Uterine Artery)
→TAD (Transverse Abdominal Diameter) →Lt Uterin A (Left Uterine Artery)
→TC (Thoracic Circumference)

→THD (Thoracic Diameter)  Cardiac measurements


→Tibia (Tibia Length) B-Mode
→TTD (Transverse Trunk Diameter) →Left Ventricular Fuction Measurement

→Ulna (Ulna Length)  Single Plane Ellipse Method

→Umb VD (Umbilical Vein Diameter)  LVALd: Left Ventricular Long-axis


→NT (Nuchal Translucency) Area at end Diastole

→LV (Lateral Ventricle)  LVLd: Left Ventricular Long-axis

→UT L (Uterus Length) Length at end Diastole

→UT H (Uterus Height)  LVALs: Left Ventricular Long-axis

→UT W (Uterus Width) Area at end Systole

→Cx (Cervix)  LVLs: Left Ventricular Long-axis

→En-T (Endometriosis) Length at end Systole

→Rt OV L (Right Ovary Length)  Biplane Ellipse Method

→Rt OV H (Right Ovary Height)  LVALd: Left Ventricular Long-axis

→Rt OV W (Right Ovary Width) Area at end Diastole

→Lt OV L (Left Ovary Length)  LVALs: Left Ventricular Long-axis

→Lt OV H (Left Ovary Height) Area at end Systole


→Lt OV W (Left Ovary Width)  LVAMd: Left ventricular short-axis

→AFI (Amniotic Fluid Index) area at end diastole

→Follicle  LVIDd: Left ventricular short-axis

page of 14
Specifications for S11 High-Performance Color System

diameter at end diastole  Cube


 LVAMs: Left ventricular short-axis  IVSTd: Interventricular septal
area at end systole thickness at end diastole

 LVIDs: Left ventricular short-axis  LVIDd: Left ventricular short-axis


diameter at end systole diameter at end diastole

 Bullet  LVPWd: Left ventricular posterior


 LVAMd: Left ventricular short-axis wall thickness at end

area at end diastole diastole

 LVAMs: Left ventricular short-axis  IVLTs: Interventricular septal

area at end systole thickness at end systole

 LVLd: Left ventricular long-axis  LVIDs: Left ventricular short-axis

length at end diastole diameter at end systole

 LVLs: Left ventricular long-axis  LVPWs: Left ventricular posterior

length at end systole wall thickness at end

 Simpson Method systole

 LVAMd: Left ventricular short-axis  Teichholz

area at end diastole  LVLDd: Left ventricular short-axis

 LVAMs: Left ventricular short-axis diameter at end diastole

area at end systole  LVIDs: Left ventricular short-axis

 LVAPd: Left ventricular short-axis diameter at end systole

area at the level of the  Gibson

papillary muscle at end  LVLDd: Left ventricular short-axis


diastole diameter at end diastole

 LVAPs: Left ventricular short-axis  LVIDs: Left ventricular short-axis


area at the level of the diameter at end systole
papillary muscle at end →Mitral Valve Diam
systole →Lv Outflow Diam
 LVLd: Left ventricularlong-axis →Pul.Valve Diam
length at end diastole M-Mode
 LVLs: Left ventricular long-axis →Left Ventricular Fuction Measurement
length at end systole  Cube

page of 14
Specifications for S11 High-Performance Color System

 LVIDd: Left ventricular short-axis →ECA (External Carotid Artery)


diameter at end diastole →CCA (Common Carotid Artery)

 LVIDs: Left ventricular short-axis →INT IL (Internal iliac)


diameter at end systole →EXT IL (External iliac)
 LVPWd: Left ventricular posterior →ILIAC (Common iliac)

wall thickness at end →CFA (Common Femoral Artery)


diastole →PROFUN (Profunda)

 LVPWs: Left ventricular posterior →LT CIR (Lateral Circumflex)

wall thickness at end →SFA(Superficial Femoral Artery)


systole →POP (Popliteal Artery)

 Gibson →PTA (Posterior Tibial Artery)

 LVLDd: Left ventricular short- →PERON (Personal Artery)

axis diameter at end →ATA (Anterior Tibial Artery)


diastole →DR PED (Dorsalis Pedis)

 LVIDs: Left ventricular short-axis →%A REDUC (Area reduction percent)

diameter at end systole →%D REDUC (Diameter reduction

 Teichholz percent)

 LVLDd: Left ventricular short- →PI (Pulsatility Index)

axis diameter at end →RI (Resistive Index)


diastole →S/D (Systolic/Diastolic Ratio)

 LVIDs: Left ventricular short-axis →PG((Pressure gradient)

diameter at end systole →PV(peak Velocity)

→Mitral Valve Measurement →IMT

→Aortic Valve Measurement

PW-Mode

→Mitral Valve Measurement

→Aortic Valve Measurement  Vascular Measurements Calculations

→Tricuspid Valve Measurement →ICA (Internal Carotid Artery)

→Pulmonary Valve Measurement

→TEI Index Doppler Measurement

page of 14
Specifications for S11 High-Performance Color System
 Urological Measurements →Bladder Volume
Calculations
→Residual Urine
→Left Kidney
 Urine Area

→Right Kidney
 Urine Height

page of 14
Specifications for S11 High-Performance Color System

 Urine Volume →Vascular report


→Whole Prostate Volume →Urological report
→Left-Seminal Vesicles →Small Part report
→Right- Seminal Vesicles →IMT report
→Left-Testicle

→Right- Testicle

→Trans Zone Volume

 Small Part Measurements

→L-Thyroid

→R-Thyroid

→Thyroid Isthmus

→L-Superior Parathyroid

→L-Inferior Parathyroid

→R-Superior Parathyroid

→R-Inferior Parathyroid

→Testis

→Seminal Vesicle

 Orthopedics Measurements
→HIP(Hip Joint)

 Report functions (Editable)


→Obstetrical /Gynecological
report

 Obstetrical Curve

 Fetal Anatomy

 Biophysical Profile (optional)

 Fetal Compare (quadruplets)

 Insert Picture

 Comment

→Cardiac function report


page of 14
Specifications for S11 High-Performance Color System

 The specifications are subject to change without notice.

 Not all the products are available in all countries.

 Please contact your local SonoScape representative.

Address: 4/F, Yizhe Building, Yuquan Road, Shenzhen, Guangdong, China

Post code: 518051

Tel: 86-755-26959990,86-755-26722890,86-755-26722860

Fax: 86-755-26722850

Website: http://www.sonoscape.com

E-mail: sonoscape@sonoscape.net

page of 14

You might also like