Comepi CAT113 SafetyDevices W

The document discusses safety limit switches with separate actuators. It describes their applications, features, components, and provides examples of product codes. Safety limit switches are used to monitor and protect industrial machines by opening control circuits when actuated.

Uploaded by

LUIZ Henrique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
197 views64 pages

Comepi CAT113 SafetyDevices W

The document discusses safety limit switches with separate actuators. It describes their applications, features, components, and provides examples of product codes. Safety limit switches are used to monitor and protect industrial machines by opening control circuits when actuated.

Uploaded by

LUIZ Henrique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 64

SAFETY DEVICES

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.
Comepi is not responsable for improper use of their electrical devices: in case you have any doubt or perplexity, please contact our Technical Service.

2
Safety Devices
Index

Safety Limit Switches with separate actuator page 4

Electromagnetic Safety Limit Switches with separate actuator page 12

Safety Hinges page 18

Hinge mount Safety Limit Switches page 24

Safety Magnetic Sensors page 30

Safety Modules page 36

Safety Limit Switches with rope page 38

Safety Limit Switches with reset page 48

3
Safety Limit Switches
Safety Limit Switches with separate actuator

Z02: Snap action 3 4 5 6 7 8 9


Y+Y
2NC Bent key Flat key Bent key Flat key Shock Shock Adjustable
absorbing absorbing joint key
bent key flat key

Z11: Snap action Zb


1NO+1NC

W02: Simultaneous Y+Y


slow action
2NC

X11: Slow action Zb


break before make
1NO+1NC SP_K series (Plastic) SDP_K series (Plastic)

Y11: Slow action Zb


make before break
1NO+1NC

X12P: Slow action Y+Y+X


break before make
1NO+2NC

X21P: Slow action Y+X+X


break before make SM_K series (Metal) SDM_K series (Metal)
2NO+1NC

W03P: Simultaneous Y+Y+Y


slow action
3NC

X12: Slow action Y+Y+X 45 46 49


break before make Bent key Flat key Adjustable
1NO+2NC joint key

X21: Slow action Y+X+X


break before make
2NO+1NC
Adapter G Type SFP_K series
(Plastic)
W03: Simultaneous Y+Y+Y
slow action
3NC

Contact blocks
Type: double break, electrically separated
SBP_K series SBM_K series SCM_K series
Approvals: UL 508 / CSA C22-2 n. 14
(Plastic) (Aluminium) (Aluminium)

4
Safety Limit Switches
Safety Limit Switches with separate actuator - Description
Applications
Easy to use, the limit switches with small latch (key) offer specific qualities:
• Capability for strong current switching (conventional thermal current 10 A).
• Opening guaranteed of the "N.C." contact(s) when the small latch is withdrawn from the limit switch.
• Contact blocks with dependent action and positive opening operation of the "N.C." normally closed contact(s) (symbol ).
• Electrically separated contacts.
• Precision on operation positions (consistency).
• Immunity to electromagnetic disturbances.
These specific features make the limit switches ideal for monitoring and protection of industrial machines without inertia in which downtime is
less than access time to the dangerous area. Use on sliding or pivoting protectors (covers, cases, doors, grids, etc.).
• They contribute to protection of operators working on dangerous machines, by opening the control circuit. Withdrawal of the small latch (key) by opening the
mobile protector causes immediate stopping of the machine drive.
• They comply with the requirements of European Directives (Low Voltage and Machines Directive) and are conform to European and international standards.
Description
Safety limit switches with small latch (key) of SP/SDP/SBP/SFP series are made of fibre-glass reinforced UL-V0 thermoplastic material, and they offer double
insulation and a degree of protection IP65. Safety limit switches of SM/SDM series are made of zinc alloy (zamack) and have a degree of protection IP66. Safety
limit switches SBM/SCM are realized in aluminium material and have a degree of protection IP66.
All models are equipped with 1NO+1NC, 2NC, 1NO+2NC, 2NO+1NC or 3NC contact blocks with positive opening operation of the "N.C." contact(s).

Casing A variety of operating inox keys:


• SP/SM with standardized dimensions acc. to EN 50047 • Flat / Bent
• SBP/SBM width with standardized dimensions acc. to EN 50041 • Shock absorbing
• Adjustable

Mounting the casing Operating head


• 2 x M4 screws on top part for SP/SM series • Fully turnable head is available for
• 2 or 4 x M4 screws on top part for SBP/SDM series SP/SDP/SM/SDM series
• 2 or 4 x M5 screws for SBP/SBM series
• 2 x M5 screws on top part for SFP/SCM series

Contact Block:
• Positive opening operation Cover:
• Snap action or slow action • 1 screw for SP/SDP series
• Contacts are electrically separated • 2 screws for SFP/SBM series
• 3 screws for SM series
• 4 screws for SDM/SCM series

Connecting terminals:
• Block of 2 contacts: M3.5 (+, –) pozidriv 2 screw Electrical connection:
• Block of 3 contacts: M3 (+, –) screw • 1 x cable gland for SP/SM/SBP/SBM series
• Screw head with captive cable clamp • 2 x cable gland for SDP series
• Markings conform with IEC 60947-1, IEC 60947-5-1 standard • 3 x cable gland for SFP/SDM/SCM series

Symbols Example: SD M 1 K 10 X 1 1
Structure: K
Casing width:
S = 30 mm width + 1 cable inlet Contact block
SB = 40 mm width + 1 cable inlet
SC = 60 mm width + 3 cable inlets
SD = 50 mm width + 2 cable inlets (SDP series) or 3 cable inlets (SDM series) 11: 1 NO + 1 NC contacts
SF = 50 mm width + 3 cable inlets 02: 2 NC contacts
12P: 1 NO + 2 NC contacts
P: Plastic casing - M: Metal (SM, SDM) / Aluminium (SBM, SCM) casing 21P: 2 NO + 1 NC contacts
03P: 3 NC contacts
Electrical connection Only for SBM, SCM, SBP series:
1: cable inlets for PG13.5 cable gland 12: 1 NO + 2NC contacts
2: cable inlets for 1/2 NPT cable gland * 21: 2 NO + 1 NC contacts
3: cable inlets for PG11 cable gland ** 03: 3 NC contacts
4: cable inlets for M16 x 1,5 cable gland **
5: cable inlets for M20 x 1,5 cable gland

Key operated version Z: Snap action


W: Slow action (contact dependent)
X: Slow action non-overlapping late make
Y: Slow action overlapping early make
Operating heads: codes 10-80-3000-4000-5000

* In SP... and SDP... series, the 1/2” NPT thread is obtained by the use of a plastic adapter (delivered not mounted). ** Available only for SP/SDP/SM/SDM Series

5
Safety Limit Switches
Safety Limit Switches with separate actuator - Technical Data
SP / SBP / SDP / SFP Series SM / SBM / SCM / SDM Series
Standards IEC 60947-5-1, EN 60947-5-1
UNI EN ISO 14119
Certifications - Approvals UL - CSA - IMQ - EAC - CCC
Air temperature near the device
– during operation °C – 25 ... + 70
– for storage °C – 30 ... + 80
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 61140) Class II Class I
Degree of protection (according to IEC 60529 and EN 60529) IP 65 IP 66

Electrical Data
Rated insulation voltage Ui
- according to IEC 60947-1 and EN 60947-1 500 V (degree of pollution 3) (400 V for contacts type Z02, X12P, X21P, W03P)
- according to UL 508 and CSA C22-2 n° 14 A 600, Q 600 (A 300, Q 300 for SM/SDM series and contacts type X12P, X21P, W03P)
Rated impulse withstand voltage Uimp
(according to IEC 60947-1 and EN 60947-1) kV 6
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 10
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 10
Rated operational current
Ie / AC-15 (according to IEC 60947-5-1) 24 V - 50/60 Hz A 10
120 V - 50/60 Hz A 6
400 V - 50/60 Hz A 4 (1.8A for contacts type X12, X21, W03)
Ie / DC-13 (according to IEC 60947-5-1) 24 V - d.c. A 6 (2.8A for contacts type X12, X21, W03)
125 V - d.c. A 0.55
250 V - d.c. A 0.4 (0.27A for contacts type X12, X21, W03)
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts m⍀ 25
Connecting terminals M3.5 (+, –) pozidriv 2 screw with cable clamp (M3 for 3 poles contacts type)
Terminal for protective conductor – M3.5 (+, –) pozidriv 2 screw with cable clamp
Connecting capacity 1 or 2 x mm2 0.75 ... 2.5 (0.34... 1.5 for 3 poles contacts type)
Terminal marking According to IEC 60947-5-1
Mechanical durability 1 million of operations
Electrical durability (according to IEC 60947-5-1) Utilization categories AC-15 and DC-13 (Load factor of 0.5 according to curves below)
B10d = 2.000.000 cycles

AC-15 - Snap action AC-15 - Slow action

DC-13 Snap action Slow action

Power breaking for a durability


of 5 million operating cycles
Voltage 24 V 9.5 W 12 W
Voltage 48 V 6.8 W 9W
Voltage 110 V 3.6 W 6W

• Ordering details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 - 11


• Additional Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60

6
Safety Limit Switches
Safety Limit Switches with separate actuator - Technical Data
Technical data approved by IMQ Technical data approved by UL
Standards Devices conform with international IEC 60947-5-1 Standards Devices conform with UL 508
and European EN 60947-5-1 standards
Degree of protection IP 65 (SP/SDP/SBP series), Contact blocks type Z11, X11, Y11, W02 and Z02
IP 66 (SM/SDM/SBM/SCM series) Utilization categories A600, Q600
Rated insulation voltage Ui 500 V (degree of pollution 3) (A300, Q300 when installed in SM/SDM series)
(400 V for contacts type Z02, X12P, X21P, W03P) Contact blocks type X12, X21, W03
Rated impulse withstand voltage Uimp 6 kV Utilization categories A600, Q600
Conventional free air thermal current Ith 10 A
Contact blocks type X12P, X21P and W03P
Short-circuit protection - gG (gl) type fuses 10 A Utilization categories A300, Q300
Rated operational current Use 60/75°C copper (Cu) conductor only. Wire rages 14-18 AWG stranded or solid. The terminal tight-
Ie / AC-15 24 V - 50/60 Hz 10 A ening torque of 7 lbs-in / 0.78 Nm. Suitable for conduit connection only with use of adapter sleeve op-
400 V - 50/60 Hz 4 A (1.8A for contacts type X12, X21, W03) tionally provided or recommended by the manufacturer.
Ie / DC-13 24 V - d.c. 6 A (2.8A for contacts type X12, X21, W03)
125 V - d.c. 0,55 A
250 V - d.c. 0.4 A (0.27A for contacts type X12, X21, W03) For the complete list of approved products, contact our technical department

Implementation

Operating head orientation Key adjustment


The head can be rotated each 90°.
Recommended tightening torque 0,5 Nm (max 0,8 Nm).

= =

Recommended tightening
torque 0,3 Nm (max 0,5 Nm).

7
Safety Limit Switches SP/SDP_K
Polymeric casing - IP65
Electrical connection: K10 Adjustable head 90° K80 Fully turnable
Replace the symbol “•” with (replaces K20) (replaces K120)
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
(with adapter)
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Operating keys to be ordered


separately (see page 11)

Min. actuating force 15 N (30N ) Min. actuating force 15 N (30N )


Weight 80 g Weight 90 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SP•K10Z11 SP•K80Z11


X11 (1NO+1NC) SP•K10X11 SP•K80X11
Y11 (1NO+1NC) SP•K10Y11 SP•K80Y11
W02 (2NC) SP•K10W02 SP•K80W02
Z02 (2NC) SP•K10Z02 SP•K80Z02
X12P (1NO+2NC) SP•K10X12P SP•K80X12P
X21P (2NO+1NC) SP•K10X21P SP•K80X21P
W03P (3NC) SP•K10W03P SP•K80W03P

K10 Adjustable head 90° K80 Fully turnable


(replaces K20) (replaces K120)

Min. actuating force 15 N (30N ) Min. actuating force 15 N (30N )


Weight 110 g Weight 120 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SDP•K10Z11 SDP•K80Z11


X11 (1NO+1NC) SDP•K10X11 SDP•K80X11
Y11 (1NO+1NC) SDP•K10Y11 SDP•K80Y11
W02 (2NC) SDP•K10W02 SDP•K80W02
Z02 (2NC) SDP•K10Z02 SDP•K80Z02
X12P (1NO+2NC) SDP•K10X12P SDP•K80X12P
X21P (2NO+1NC) SDP•K10X21P SDP•K80X21P
W03P (3NC) SDP•K10W03P SDP•K80W03P

8
Safety Limit Switches SM/SDM_K
Metal casing - IP66
Electrical connection: K10 Adjustable head 90° K80 Fully turnable
Replace the symbol “•” with (replaces K20) (replaces K120)
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Operating keys to be ordered


separately (see page 11)

Min. actuating force 15 N (30N ) Min. actuating force 15 N (30N )


Weight 175 g Weight 185 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SM•K10Z11 SM•K80Z11


X11 (1NO+1NC) SM•K10X11 SM•K80X11
Y11 (1NO+1NC) SM•K10Y11 SM•K80Y11
W02 (2NC) SM•K10W02 SM•K80W02
Z02 (2NC) SM•K10Z02 SM•K80Z02
X12P (1NO+2NC) SM•K10X12P SM•K80X12P
X21P (2NO+1NC) SM•K10X21P SM•K80X21P
W03P (3NC) SM•K10W03P SM•K80W03P

K10 Adjustable head 90° K80 Fully turnable


(replaces K20) (replaces K120)

Min. actuating force 15 N (30N ) Min. actuating force 15 N (30N )


Weight 235 g Weight 245 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SDM•K10Z11 SDM•K80Z11


X11 (1NO+1NC) SDM•K10X11 SDM•K80X11
Y11 (1NO+1NC) SDM•K10Y11 SDM•K80Y11
W02 (2NC) SDM•K10W02 SDM•K80W02
Z02 (2NC) SDM•K10Z02 SDM•K80Z02
X12P (1NO+2NC) SDM•K10X12P SDM•K80X12P
X21P (2NO+1NC) SDM•K10X21P SDM•K80X21P
W03P (3NC) SDM•K10W03P SDM•K80W03P

9
Safety Limit Switches SBP/SFP/SBM/SCM_K
Key operated
Electrical connection: K3000 Adjustable head 90° K5000 Adjustable head 90°
Replace the symbol “•” with
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
5: Cable gland M20 x 1,5

Operating keys to be ordered


separately (see page 11)

Min. actuating force 15 N (30N ) Initial minimum activating force 60 N (90N )


Weight 155 g Weight 140 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SBP•K3000Z11 SFP5K5000Z11


X11 (1NO+1NC) SBP•K3000X11 SFP5K5000X11
Y11 (1NO+1NC) SBP•K3000Y11 SFP5K5000Y11
W02 (2NC) SBP•K3000W02 SFP5K5000W02
Z02 (2NC) SBP•K3000Z02 SFP5K5000Z02
X12 (1NO+2NC) SBP•K3000X12 SFP5K5000X12P
X21 (2NO+1NC) SBP•K3000X21 SFP5K5000X21P
W03 (3NC) SBP•K3000W03 SFP5K5000W03P

K4000 Adjustable head 90° K4000 Adjustable head 90°

Min. actuating force 15 N (30N ) Min. actuating force 15 N (30N )


Weight 225 g Weight 220 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SBM•K4000Z11 SCM•K4000Z11


X11 (1NO+1NC) SBM•K4000X11 SCM•K4000X11
Y11 (1NO+1NC) SBM•K4000Y11 SCM•K4000Y11
W02 (2NC) SBM•K4000W02 SCM•K4000W02
Z02 (2NC) SBM•K4000Z02 SCM•K4000Z02
X12 (1NO+2NC) SBM•K4000X12 SCM•K4000X12
X21 (2NO+1NC) SBM•K4000X21 SCM•K4000X21
W03 (3NC) SBM•K4000W03 SCM•K4000W03

10
Safety Limit Switches Accessories
Operating keys (to be ordered separately)
For operating head models K10 and K80 (dimensions in mm.)

Order code 3: Bent key Order code 4: Flat key Order code 5: Bent key

Order code 6: Flat key Order code 7: Shock absorbing bent key Order code 8: Shock absorbing flat key

Order code 9: Adjustable joint key

For operating head models K3000, K4000, K5000 (dimensions in mm.)

Order code 45: Bent key Order code 46: Flat key Order code 49: Adjustable joint key

Minimum values [mm]

KEY 3 KEY 4 KEY 5/45 KEY 6/46 KEY 7 KEY 8 KEY 9/49

R1 400 400 400 400 250 350 180


R2 400 400 400 400 350 350 200

11
Electromagnetic Safety Devices
Electromagnetic safety devices with separate actuator
Approvals: UL 508 / EN 60947-5-1

25 26 27 28 29
Bent Flat Shock Shock Adjustable
key key absorbing absorbing joint
bent key flat key key

Coil power supply


Head orientation - 024: 24 Vac/dc
Cable entry - 1: front - 120: 120 Vac/dc
3 x (M20x1) - 2 ...4: turn 90° - 180° - 270° - 230: 230 Vac/dc

Polimeric Polimeric Auxiliary contacts E: Electrical block


casing head - FA1: 3NC + 1NO M: Mechanical block
- FA2: 2NC + 2NO
- FA3: 1NO + 3NC

12
Electromagnetic Safety Devices
Electromagnetic safety devices with separate actuator - Description
Applications
This device is useful for guarantee the safety of the operator in case of machines where the hazardous conditions remains for a while time after the generation
of the stop signal, because of the mechanical inertia of moving parts, components under pressure or with high temperatures. This device, when used individually,
is not suitable for applications in machines where the operator can enter inside the protected area with his whole body, because of the possibility of accidental
closing of the protection fences after the operator entry. In order to test the proper operations, verify the correct insertion of the actuator in the operating head
and start the machine by closing the protection. In this conditions must be impossible to open the protection. With the machine stopped and disconnected pro-
tection, must be impossible to start the machine.

Safety warnings
Safety switches perform a human protection function. The wrong installation can cause serious danger situations, as well as the manumission of the device and
of the entire safety system. The device must never be evaded or manumitted in every way. To prevent easy tampering, we recommend to install the device in a
place difficult to access by unauthorized personnel, by using physical impediments or tricks to make any tampering more difficult.

13
Electromagnetic Safety Devices
Electromagnetic safety devices with separate actuator - Technical Data
FEP Series
Standards IEC 60947-1, EN 60947-5-1
UNI EN ISO 14119, EN 60204
Certifcations - Approvals UL - IMQ - CCC
Air temperature near the device
– during operation °C – 25 ... + 55
– for storage °C – 30 ... + 80
Mounting positions Head not removable by the user
Protection against electrical shocks (according to IEC 61140) Class II
Degree of protection (according to IEC 60529 and EN 60529) IP 65

Electrical Data
Rated insulation voltage Ui
- according to IEC 60947-1 and EN 60947-1 250 V (pollution degree 3)
- according to UL 508 A 300, Q 300
Rated impulsive withstand voltage Uimp
(according to IEC 60947-1 and EN 60947-1) kV 2.5
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 10
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 10
Rated operational current
Ie / AC-15 (according to IEC 60947-5-1) 24 V - 50/60 Hz A 10
230 V - 50/60 Hz A 4

Ie / DC-13 (according to IEC 60947-5-1) 24 V - d.c. A 4

Max switching frequency cycles / h 600


Max actuation speed m/min 20
Resistance between contacts m⍀ 25
Connecting terminals M3 screw with cable clamp
Connecting capacity 1 o 2 x mm2 0.34... 1.5
Terminal marking according to IEC 60947-5-1
Mechanical durability million of operations 1
B10d million of operations 4

14
Electromagnetic Safety Devices
Electromagnetic safety devices with separate actuator - Technical Data
Techical data approved by IMQ Techical data approved by UL
Standards Devices conform Standards Devices conform with UL 508
with international IEC 60947-5-1 Utilization categories A300, Q300
and European EN 60947-5-1 standards
Degree of protection IP 65 Use 60/75°C copper (Cu) conductor only. Wire rages 14-18 AWG stranded or solid.
Rated insulation voltage Ui 250 V (pollution degree 3) The terminal tightening torque of 7.1 lbs in / 0.8 Nm. Suitable for conduit connection only with use of
Rated impulse withstand voltage Uimp 2.5 kV adapter sleeve optionally provided or recommended by the manufacturer.
Operating ambient temp.: 40°C - Type 1 encl.
Conventional free air thermal current Ith 10 A
Short-circuit protection - gG (gl) type fuses 10 A
Rated operational current
Ie / AC-15 24 V - 50/60 Hz 10 A
230 V - 50/60 Hz 4A
Ie / DC-13 24 V - d.c. 4A For the complete list of approved products, contact our technical department.

Implementation

Operating head orientation Key adjustment


Head not removable by the user.
The head can be rotated in factory each 90°.

= =

15
Electromagnetic Safety Devices FEP
Electromagnetic safety devices with separate actuator
Head orientation: FEP-M Mechanical interlock FEP-E Electrical interlock Dimensions
Replace the symbol “•” with
the number of the orientation
desired
1: 0° standard
2: 90° right
3: 180° right
4: 270° rigt

Operating keys to be ordered


separately (see page 17)

Min. actuating force (extraction) 15 N (30N) Min. actuating force (extraction) 15 N (30N)
Retention force 1200 N Retention force 1200 N
Contact Blocks Weight 0,5 kg Weight 0,5 kg

FA1 (3NC+1NA) FEP5KP•FA1-024M FEP5KP•FA1-024E


FEP5KP•FA1-120M FEP5KP•FA1-120E
FEP5KP•FA1-230M FEP5KP•FA1-230E
FA2 (2NA+2NC) FEP5KP•FA2-024M FEP5KP•FA2-024E
FEP5KP•FA2-120M FEP5KP•FA2-120E
FEP5KP•FA2-230M FEP5KP•FA2-230E
FA3 (1NA+3NC) FEP5KP•FA3-024M FEP5KP•FA3-024E
FEP5KP•FA3-120M FEP5KP•FA3-120E

Contact elements definition


FEP5KP•FA3-230M FEP5KP•FA3-230E

Contact identification Type Mechanical interlock Electrical interlock*

Actuator Inserted and locked Inserted and unlocked Not inserted Inserted and locked Inserted and unlocked Not inserted

Solenoid Not excited Excited – Excited Not excited –

Contact elements Actuation

FA1 Actuator
1 contact moved by actuator
Solenoid
+
3 contacts moved by solenoid Solenoid
Solenoid
FA2 Actuator
1 contact moved by actuator
Solenoid
+
3 contacts moved by solenoid Solenoid
Solenoid
FA3 Actuator
2 contact moved by actuator
Solenoid
+
2 contacts moved by solenoid Solenoid
Actuator

* ATTENTION: in case of lack of voltage the device allows immediate access to the protected area.

16
Electromagnetic Safety Devices FEP
Operating keys (to be ordered separately)
For operating head model KP (dimensions in mm.)

Order code 25: Bent key Order code 26: Flat key Order code 27: Shock absorbing bent key

Order code 28: Shock absorbing flat key Order code 29: Adjustable joint key

17
Safety Hinges
Safety Hinges

SPH1•••UA SPH1•••UB

X22C: Slow action Y+Y+X+X

break before make SPH1•••UC


2NO+2NC

X13C: Slow action Y+Y+Y+X

break before make


1NO+3NC

SPH1•••MA SPH1•••MC

Complementary Mechanical hinges

Contact blocks SPH1-COMP1 SPH1-COMP2


Type: double break, electrically separated
Approvals: UL 508 / CSA C22-2 n. 14

18
Safety Hinges
Safety hinges - Description
Applications
Within the range of safety devices, Comepi has created a new hinge with multiple integrated circuit which can suit all applications where high security is combined
with a modern and sophisticate design. Thanks to its small sizes and numerous mounting options and connection (cable/connectors), the device is easily installed
on most common aluminium profiles (minimum width 30 mm.). Its installation is also facilitated by the integration of a safety switch integrated into a single body,
thus avoiding the need to separately install a mechanical hinge and a safety switch connected via a special pin.
The use of stainless steel components and the degree of protection IP67 permit the hinge to be subjected to frequent washing and to be used in environments
where cleanliness and hygiene require maximum attention. The Comepi hinge was developed and manufactured according to the rules set out in IEC international
publications and to applicable EN European Standards; the use of a redundant system and a proper configuration allows to obtain a safety system of machinery up
to SIL 3 or PLe according to EN ISO 13849-1.

Description
Both the self-extinguishing body of the hinge and the rotation pin are made of technopolymer with high-rigidity capable of resisting to solvents, oils, greases and
various chemical agents. The internal switch is composed of 4 slow action double break contacts. The positive opening (according to IEC EN 60947-5-1) is guaranteed
on all NC contacts. All the circuits have a low contact resistance thanks to the self-cleaning action of the silver pastes.
Each hinge is supplied with the following kit:
- n°4 technopolymer covers (to avoid free access to screws):
- n°4 technopolymer bushings (for hexagon socket or nut M6).
- n°2 thermoplastic elastomer safety plugs to guarantee IP67 protection degree.

Casing Electrical connection:


• Made of self-extinguishing technopolimer • Cable 8x0,34 mm2 PVC cable
standard lenghts: 2m and 5m
• M12 connector

Mounting the casing


• 4 x M6 screws UNI 5933 ISO 10642 countersunk-head screws Contact Block:
• 4 x cylindrical head screws with hexagon socket M6 UNI 5931 • Positive opening operation
ISO 4762 • 2NO+2NC or 1NO+3NC slow action contacts
• 4 x M6 UNI 5588 ISO 4032 nut • Contacts are electrically separated

Screws and nuts are not supplied

Totally sealed for IP 67 protection degree

Symbols Example: S P H 1 X22C 020 U A


Structure: S P H 1
Output
Contact block
A: top axial
X22C: Slow action non-overlapping late make 2 NO + 2 NC contacts
B: back
X13C: Slow action non-overlapping late make 1 NO + 3 NC contacts
C: bottom axial

Type of connection
Standard executions
020: 2m UL PVC cable
U: 8x0,34 mm2 PVC cable
050: 5m UL PVC cable
M: 8 poles M12 connector
Null: Integrated M12 connector

Other versions of cable and electrical contacts are available on request: contact our sales department.

19
Safety Hinges
Safety hinges - Technical Data
SPH Series
Standards IEC 60947-5-1, EN 60947-5-1
UNI EN ISO 14119
Certifications - Approvals UL - IMQ - EAC - CCC
Air temperature near the device
– during operation °C – 20 ... + 80
– for storage °C – 20 ... + 80
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 536) Class II
Degree of protection (according to IEC 529 and EN 60 529) IP 67

Electrical Data
Rated insulation voltage Ui
- according to IEC 947-1 and EN 60-947-1 400 V (degree of pollution 3) (24 V for M12 connector)
- according to UL 508 and CSA C22-2 n° 14 C 300, Q 300 (class II for M12 connector)
Rated impulse withstand voltage Uimp
(according to IEC 947-1 and EN 60 947-1) kV 4 (2,5 for M12 connector)
Conventional free air thermal current Ith
(according to IEC 947-5-1) ␪ < 40 °C A 4 (2,5 for M12 connector)
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 4
Rated operational current
Ie / AC-15 (according to IEC 947-5-1) 24 V - 50/60 Hz A 4
120 V - 50/60 Hz A 4
250 V - 50/60 Hz A 4
400 V - 50/60 Hz A 4
Ie / DC-13 (according to IEC 947-5-1) 24 V - d.c. A 2
125 V - d.c. A 0.4
250 V - d.c. A 0.3
Switching frequency Cycles/h 1200
Mechanical durability 1 million of operations
B10d = 2.000.000 operations

Operating diagrams
X22C X13C

As shown in the travel diagrams, the angle of action is set at the factory to 5° (opening of the NC contacts, to be verified according to EN294).
This angle and consequently also angles relating to the closure of the NO contact and positive opening of the NC contacts can be adjusted by the installer; in the
case of doors of considerable size, the operating angle can be reduced up to 1° operating with a screwdriver on the adjustment screw. The degree of protection IP67
is then secured by inserting the appropriate safety plug (not removable) in the adjustment hole.
It is recommended to verify the correct operation of the device before starting up the machine and we suggest to repeat the test periodically.

Special executions on request


• Operating angle of the hinge other than from 0° to 180°, every 15°, where the system frame/door requires a special execution.
• NC and NO contact blocks setting (up to 4 NC).
• NO and NC ovelapping contacts.

20
Safety Hinges
Safety hinges - Technical Data
Technical data approved by IMQ Technical data approved by UL
Standards Devices conform with international IEC 60947-5-1 Standards Devices conform with UL 508
and European EN 60947-5-1 standards Utilization categories
Degree of protection IP 67 Cable “U-Type” C300, Q300
Rated insulation voltage Ui 400 V (degree of pollution 3) Connector / Cable+Connector “M-Type” 24 V / 2 A Class II
Rated impulse withstand voltage Uimp 4 kV (2,5 kV for M12 connector)
Conventional free air thermal current Ith 4 A (2,5 A for M12 connector)
Short-circuit protection - gG type fuses 4A
Rated operational current
Ie / AC-15 24 V - 50/60 Hz 4A
120 V - 50/60 Hz 4A
250 V - 50/60 Hz 4A
400 V - 50/60 Hz 4A
Ie / DC-13 24 V - d.c. 2A
125 V - d.c. 0.4 A
250 V - d.c. 0.3 A
For the complete list of approved products, contact our technical department

Implementation
Determination of maximum applicable load
For SPH1 hinges with built-in safety multiple switch, the reference value supplied is the max limit static load
(Sa, Sr, S90), since these hinges can be used as safety devices.
Above this value, the material may break, thus prejudicing the hinge functionality. Obviously a suitable factor,
according to the importance and safety level of the specific application, must be applied to this value. The
load values shown in the tables of the different hinges are the result of tests carried out in our laboratories
under controlled temperature and humidity (23°C-50% R.H.), under given conditions of use and for a limited
period of time.

Example of suitability check


P weight of the door [N] The technical designer must use suitable safety fac-
P1 additional extra load [N] tors (k) according to the type of application and fun-
W width of the door ction of the SPH1 hinge.
D distance [metres] between the centre of gravity
of the door and the hinge axis. In normal con-
ditions D = W/2
D1 distance [metres] between the hinge axis and
the additional extra load application point
N number of hinges
k safety factor
dT sum of the distances [metres] of all the hinges
from the hinge of reference (d = d + d + ... +
dn). In case of only two hinge assembled, d is
simply the distance between them

The examples shown here must be considered only


Conditions to be checked in order to ensure a correct as explanatory, since they are not applicable to all
functioning with two or more hinges the different applications, conditions of use, ways of
assembly which can actually take place.
In practice, the technical designer, after applying a
suitable safety factor (k) must also test the chosen
product to check its suitability.

21
Safety Hinges
Polymeric casing. IP67
Electrical connection: Top axial exit with cable Back exit with cable Bottom axial exit with cable
Replace the symbol “•••” with
the lenght of the cable desired
020: Cable lenght 2m
050: Cable lenght 5m

Min. actuating torque 0,5 Nm Min. actuating torque 0,5 Nm Min. actuating torque 0,5 Nm
Weight 280 g Weight 280 g Weight 280 g
Contact Blocks Operating diagram Page 20 Operating diagram Page 20 Operating diagram Page 20

X22C (2NO+2NC) SPH1X22C•••UA SPH1X22C•••UB SPH1X22C•••UC


X13C (1NO+3NC) SPH1X13C•••UA SPH1X13C•••UB SPH1X13C•••UC

Top axial exit with M12 connector Bottom axial exit with M12 connector

Min. actuating torque 0,5 Nm Min. actuating torque 0,5 Nm


Weight 140 g Weight 140 g
Contact Blocks Operating diagram Page 20 Operating diagram Page 20

X22C (2NO+2NC) SPH1X22CMA SPH1X22CMC


X13C (1NO+3NC) SPH1X13CMA SPH1X13CMC

22
Safety Hinges
Safety hinges - Accessories
Complementary mechanical Complementary hinge 70 mm Complementary hinge 110 mm
hinges
Glass-fibre reinforced
technopolymer

Weight 85 g Weight 130 g

SPH1-COMP1 SPH1-COMP2

Art Description Art. Description


SPH-FX1 Couple of supports for safety hinges SPH1 series (fixing screws SPH-FX2 Couple of supports for complementary hinges SPH1-COMP1
for switch included) series (fixing screws for switch included)

The mounting brackets are used in the presence of profiles with slots having a different pitch from the standard pitch of
the hinge (40 mm).

23
Safety Limit Switches
Hinge mount Safety Limit Switches

K71 K72 K61


Zinc plated Stainless Zinc plated
steel shaft steel shaft steel lever

Z02: Snap action Y+Y


2NC

Z11: Snap action Zb


1NO+1NC

W02: Simultaneous Y+Y


slow action
2NC

SP_K series (Plastic) SDP_K series (Plastic)


X11: Slow action Zb
break before make
1NO+1NC

Y11: Slow action Zb


make before break
1NO+1NC

X12P: Slow action Y+Y+X


break before make
1NO+2NC
SM_K series (Metal) SDM_K series (Metal)
X21P: Slow action Y+X+X
break before make
2NO+1NC

W03P: Simultaneous Y+Y+Y


slow action
3NC

Contact blocks
Type: double break, electrically
separated
Approvals: UL 508 / CSA C22-2 n. 14

24
Safety Limit Switches
Hinge mount Safety Limit Switches - Description
Applications
Easy to use, the limit switches with rotative axis or lever offer specific qualities:
• Capability for strong current switching (conventional thermal current 10 A).
• Opening of the "N.C." contact(s) for a very small rotation angle: 12°.
• Contact blocks with dependent action and positive opening operation of the "N.C." normally closed contact(s) (symbol ).
• Electrically separated contacts.
• Precision on operating positions (consistency).
• Immunity to electromagnetic disturbances.
These specific features make the limit switches ideal for monitoring and protection of light industrial machines without inertia equipped with
angular movement protectors (doors, hinged grids, rotative covers or cases, etc.). Detection by the rotative axis or by means of a lever.
• Opening of the mobile protector guarantees operator protection by immediately stopping the machine drive.
• These switches are suitable for conformity of the existing installed machine base, as they can be mounted on protection devices already installed.
• They comply with the requirements of European Directives (Low Voltage and Machines Directive) and are conform to European and international standards.
Description
Safety limit switches of SP/SDP series are made of fibre-glass reinforced UL-V0 thermoplastic material, and the offer double insulation and a degree of protection
IP65. Safety limit switches of SM/SDM series are made of zinc alloy (zamack) and have a degree of protection IP66. They are equipped with 1NO+1NC, 2NC,
1NO+2NC, 2NO+1NC or 3NC contact blocks with positive opening operation of the "N.C." contact(s).

Casing A variety of operating heads:


• 30 mm. width with standardized dimensions acc. to EN 50047 • Zinc plated steel shaft
• 50 mm. width with standardized dimensions • Stainless steel shaft
• Zinc plated steel lever

Mounting the casing


• 2 x M4 screws on top part for 30 mm. width
• 2 or 4 x M4 screws on top part for 50 mm. width

Contact Block:
• Positive opening operation
• Snap action or slow action Cover:
• Contacts are electrically separated • 1 or 3 screws for 30 mm. casing
• 1 or 4 screws for 50 mm. casing

Connecting terminals: Electrical connection:


• Block of 2 contacts: M3.5 (+, –) pozidriv 2 screw • 1 x cable gland for SP and SM series
• Block of 3 contacts: M3 (+, –) screw • 2 x cable gland for SDP series
• Screw head with captive cable clamp • 3 x cable gland for SDM series
• Markings conform with IEC 60947-1, IEC 60947-5-1 standard

Symbols Example: S P 1 K 71 X 1 1
Structure: K

Casing width: Contact block


S = 30 mm width + 1 cable inlet
SD = 50 mm width + 2 cable inlets (SDP series)
or 3 cable inlets (SDM series) 11: 1 NO + 1 NC contacts
02: 2 NC contacts
12P: 1 NO + 2 NC contacts
P: Plastic casing M: Metal casing 21P: 2 NO + 1 NC contacts
03P: 3 NC contacts
Electrical connection
1: cable inlets for PG13.5 cable gland
2: cable inlets for 1/2 NPT cable gland *
Z: Snap action
3: cable inlets for PG11 cable gland
W: Slow action (contact dependent)
4: cable inlets for M16 x 1,5 cable gland
X: Slow action non-overlapping late make
5: cable inlets for M20 x 1,5 cable gland
Y: Slow action overlapping early make

Operating heads: codes 71-72-61

* In SP... and SDP... series, the 1/2” NPT thread is obtained by the use of a plastic adapter (delivered not mounted).

25
Safety Limit Switches
Hinge mount Safety Limit Switches - Technical Data
SP / SDP Series SM / SDM Series
Standards IEC 60947-5-1, EN 60947-5-1
UNI EN ISO 14119
Certifications - Approvals UL - CSA - IMQ - EAC - CCC
Air temperature near the device
– during operation °C – 25 ... + 70
– for storage °C – 30 ... + 80
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 61140) Class II Class I
Degree of protection (according to IEC 60529 and EN 60529) IP 65 IP 66

Electrical Data
Rated insulation voltage Ui
- according to IEC 60947-1 and EN 60947-1 500 V (degree of pollution 3) (400 V for contacts type Z02, X12P, X21P, W03P)
- according to UL 508 and CSA C22-2 n° 14 A 600, Q 600 (A 300, Q 300 for SM/SDM series and contacts type X12P, X21P, W03P)
Rated impulse withstand voltage Uimp
(according to IEC 60947-1 and EN 60947-1) kV 6
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 10
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 10
Rated operational current
Ie / AC-15 (according to IEC 60947-5-1) 24 V - 50/60 Hz A 10
120 V - 50/60 Hz A 6
400 V - 50/60 Hz A 4
Ie / DC-13 (according to IEC 60947-5-1) 24 V - d.c. A 6
125 V - d.c. A 0.55
250 V - d.c. A 0.4
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts m⍀ 25
Connecting terminals M3.5 (+, –) pozidriv 2 screw with cable clamp (M3 for 3 poles contacts type)
Terminal for protective conductor – M3.5 (+, –) pozidriv 2 screw with cable clamp
Connecting capacity 1 or 2 x mm2 0.75 ... 2.5 (0.34... 1.5 for 3 poles contacts type)
Terminal marking According to IEC 60947-5-1
Mechanical durability 1 million of operations
Electrical durability (according to IEC 60947-5-1) Utilization categories AC-15 and DC-13 (Load factor of 0.5 according to curves below)
B10d = 2.000.000 cycles

AC-15 - Snap action AC-15 - Slow action

DC-13 Snap action Slow action

Power breaking for a durability


of 5 million operating cycles
Voltage 24 V 9.5 W 12 W
Voltage 48 V 6.8 W 9W
Voltage 110 V 3.6 W 6W

• Ordering details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 28 - 29


• Additional Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60

26
Safety Limit Switches
Hinge mount Safety Limit Switches - Technical Data
Technical data approved by IMQ Technical data approved by UL
Standards Devices conform with international IEC 60947-5-1 Standards Devices conform with UL 508
and European EN 60947-5-1 standards
Degree of protection IP 65 (SP/SDP series) , IP 66 (SM/SDM series) Contact blocks type Z11, X11, Y11, W02 and Z02
Rated insulation voltage Ui 500 V (degree of pollution 3) Utilization categories A600, Q600
(400V for type Z02, X12P, X21P, W03P) (A300, Q300 when installed in SM/SDM series)
Rated impulse withstand voltage Uimp 6 kV
Contact blocks type X12P, X21P and W03P
Conventional free air thermal current Ith 10 A
Utilization categories A300, Q300
Short-circuit protection - gG (gl) type fuses 10 A Use 60/75°C copper (Cu) conductor only. Wire rages 14-18 AWG stranded or solid. The terminal tight-
Rated operational current ening torque of 7 lbs-in / 0.78 Nm. Suitable for conduit connection only with use of adapter sleeve op-
Ie / AC-15 24 V - 50/60 Hz 10 A tionally provided or recommended by the manufacturer.
400 V - 50/60 Hz 4A
Ie / DC-13 24 V - d.c. 6A
125 V - d.c. 0.55 A
250 V - d.c. 0.4 A
For the complete list of approved products, contact our technical department

Implementation

Operating head orientation Lever adjustment


The head can be rotated each 90°. The lever of the head model K61 can ber adjusted every 10° in order to obtain
Recommended tightening torque 0,5 Nm (max 0,8 Nm). the maximum flexibility on the working plan.
Recommended tightening torque 0,5 Nm (max 0,8 Nm).

27
Safety Limit Switches SP/SDP_K
Polymeric casing - IP65
Electrical connection: K71 Zinc plated steel shaft K72 Stainless steel shaft K61 Zinc plated steel lever
Replace the symbol “•” with
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
(with adapter)
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm )
Weight 90 g Weight 90 g Weight 110 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SP•K71Z11 SP•K72Z11 SP•K61Z11


X11 (1NO+1NC) SP•K71X11 SP•K72X11 SP•K61X11
Y11 (1NO+1NC) SP•K71Y11 SP•K72Y11 SP•K61Y11
W02 (2NC) SP•K71W02 SP•K72W02 SP•K61W02
Z02 (2NC) SP•K71Z02 SP•K72Z02 SP•K61Z02
X12P (1NO+2NC) SP•K71X12P SP•K72X12P SP•K61X12P
X21P (2NO+1NC) SP•K71X21P SP•K72X21P SP•K61X21P
W03P (3NC) SP•K71W03P SP•K72W03P SP•K61W03P

K71 Zinc plated steel shaft K72 Stainless steel shaft K61 Zinc plated steel lever

Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm )
Weight 120 g Weight 120 g Weight 140 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SDP•K71Z11 SDP•K72Z11 SDP•K61Z11


X11 (1NO+1NC) SDP•K71X11 SDP•K72X11 SDP•K61X11
Y11 (1NO+1NC) SDP•K71Y11 SDP•K72Y11 SDP•K61Y11
W02 (2NC) SDP•K71W02 SDP•K72W02 SDP•K61W02
Z02 (2NC) SDP•K71Z02 SDP•K72Z02 SDP•K61Z02
X12P (1NO+2NC) SDP•K71X12P SDP•K72X12P SDP•K61X12P
X21P (2NO+1NC) SDP•K71X21P SDP•K72X21P SDP•K61X21P
W03P (3NC) SDP•K71W03P SDP•K72W03P SDP•K61W03P

28
Safety Limit Switches SM/SDM_K
Metal casing - IP66
Electrical connection: K71 Zinc plated steel shaft K72 Stainless steel shaft K61 Zinc plated steel lever
Replace the symbol “•” with
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm )
Weight 185 g Weight 185 g Weight 205 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SM•K71Z11 SM•K72Z11 SM•K61Z11


X11 (1NO+1NC) SM•K71X11 SM•K72X11 SM•K61X11
Y11 (1NO+1NC) SM•K71Y11 SM•K72Y11 SM•K61Y11
W02 (2NC) SM•K71W02 SM•K72W02 SM•K61W02
Z02 (2NC) SM•K71Z02 SM•K72Z02 SM•K61Z02
X12P (1NO+2NC) SM•K71X12P SM•K72X12P SM•K61X12P
X21P (2NO+1NC) SM•K71X21P SM•K72X21P SM•K61X21P
W03P (3NC) SM•K71W03P SM•K72W03P SM•K61W03P

K71 Zinc plated steel shaft K72 Stainless steel shaft K61 Zinc plated steel lever

Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm ) Min. actuating torque 0,12 Nm (0,60 Nm )
Weight 245 g Weight 245 g Weight 265 g
Contact Blocks Operating diagram Page 60 Operating diagram Page 60 Operating diagram Page 60

Z11 (1NO+1NC) SDM•K71Z11 SDM•K72Z11 SDM•K61Z11


X11 (1NO+1NC) SDM•K71X11 SDM•K72X11 SDM•K61X11
Y11 (1NO+1NC) SDM•K71Y11 SDM•K72Y11 SDM•K61Y11
W02 (2NC) SDM•K71W02 SDM•K72W02 SDM•K61W02
Z02 (2NC) SDM•K71Z02 SDM•K72Z02 SDM•K61Z02
X12P (1NO+2NC) SDM•K71X12P SDM•K72X12P SDM•K61X12P
X21P (2NO+1NC) SDM•K71X21P SDM•K72X21P SDM•K61X21P
W03P (3NC) SDM•K71W03P SDM•K72W03P SDM•K61W03P

29
Safety Magnetic Sensors
7 mm Safety Magnetic Sensors
Safety Magnetic Target - SMP1 series

Actuation distance 5 mm

SMP1AMG

Safety Magnetic Sensors

Contacts
2NC

1NO + 1NC SMP1A••• SMP1A•••K SMP1A•••001M

1NO + 2NC

SMP1A•••L SMP1A•••KL SMP1A•••001ML

Safety Magnetic Target - SMP2 series

Actuation distance 5 mm Actuation distance 8 mm

SMP2AMG SMP2BMG

Safety Magnetic Sensors

Contacts
2NC

1NO + 1NC
SMP2A••• SMP2A•••K SMP2A•••001M

1NO + 2NC

SMP2A•••L SMP2A•••KL SMP2A•••001ML

30
Safety Magnetic Sensors
Safety Magnetic Sensors - Description
Applications
Comepi offers a range of safety magnetic sensors SMP series designed to satisfy applications requiring high safety standards. Combined with an appropriate safety
module, SMP magnetic sensors guarantee a safety system with Safety Integraty Level (SIL CL) up to SIL 3 (according to EN 62061) and Performance Level up to
PLe (according to EN ISO 13849-1).
• Sealed: immune to dirt
• Wide actuation zone
• Difficult to by-pass as they can be easily hidden (with non-magnetic material)
• Electrical output contacts: 2NC, 1NO + 1NC or 1NO + 2NC
• Optionally provided with LED indicator
• Intervention from all directions

They comply with the requirements of European Directives (Low Voltage, Machines and Electromagnetic Compatibility) and are conform to European and international
standards.

Description
The housing is made of technopolymer and it offers a degree of protection IP67. Integrated cable or M8 / M12 connection allow to install these devices in the most
varied applications.

Housing
• 36 mm. width LED indicator
• 88 mm. width • Optionally provided on all models

Housing fixing
• 2 x M4 screws

Electrical connection:
• PVC cable
Output contacts:
• M8 integrated connector
• 2NC, 1NO + 2NC, 1NO + 1NC contacts
(only for 2NC and 1NO + 1NC contacts)
• PVC cable + M12 connector

Symbols Example: SMP 1A 11 S 010


Structure: SMP
Housing dimensions Direction of the Output Connection
1A: 36 x 26 x 13 mm. Null: Right
2A: 88 x 25 x 13 mm. L: Left

Connection type
Null: PVC cable
K: M8 integrated connector
M: M12 connector

Contacts (with closed protection)


02: 2NC contacts Cable lenght
12: 1NO + 2NC contacts 010: 1 m. PVC cable
11: 1NO + 1NC contacts 020: 2 m. PVC cable
001: 10 cm. PVC cable (M12 + cable version only)
Null: Connector

Version
S: Standard
L: With LED indicator

31
Safety Magnetic Sensors
Safety Magnetic Sensors - Technical Data
SMP Series
Temperature range
– Operation °C – 25 ... + 80
– Storage °C – 25 ... + 80
Mounting positions All positions are authorised
Degree of protection (according to IEC 60529 and EN 60 529) IP 67
Pollution degree (according to IEC 60947-5-1) 3
Sil level (Sil CL) (according to EN IEC 62061) Up to Sil 3 (*)
Performance level (PL) (according to EN ISO 13849-1) Up to PLe (*)
Safety category (according to EN ISO 13849-1) Up to Cat 4 (*)
B10d for each channel 20.000.000 (*) / 400.000 (used with max load: 24V - 0,25A)
(*) Connecting a single sensor to a COMEPI safety module MS1A31...*.

Electrical Data
Rated insulation voltage Ui
according to IEC 60947-1 and EN 60947-1 120 Vac (cable connection and cable +M12 4 poles connector)
60 Vac / 75 Vdc (M8 connector)
30 Vac / 36 Vdc (M12 8 poles connector)
Rated impulse withstand voltage Uimp kV 6 (1,5 for M8 or M12 connectors)
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 0,25
Rated voltage / current 24 Vac / dc - 0,25 A (resistive load)
Max resistive load W 6 (external fuse 0,25 A type F)
Electrical durability 1.000.000 operations

Approvals
Standards EN 60947-1, EN 60947-5-1, EN 60947-5-2, EN 60947-5-3 (*) , EN ISO 14119, EN ISO 12100-1, EN ISO 12100-2, EN ISO 13849-1,
EN ISO 13849-2, EN 60204-1, EN 60529
Directives 2006/95/CE low voltage
2006/42/CE machinery
2004/108/CE electromagnetic
Certifications CE

32
Safety Magnetic Sensors
Safety Magnetic Sensors - Technical Data
Implementation

SMP1AMG
Switching distance Minimum distance between sensors

SMP2AMG
Switching distance Minimum distance between sensors

Electrical connections
Cable connections M8 connections Cable + M12 connections Example of connection with safety module
2NC 2NC 2NC

Grey
1NO+2NC White 1NO+2NC
Green

Yallow
Brown
Pink

1NO+1NC 1NA+1NC 1NO+1NC

33
Safety Magnetic Sensors
SMP1 - Polymeric housing - IP67
Safety Magnetic Target Cable connection Cable connection M8 integrated connector
SMP1AMG
Actuation distance: 5 mm.

Weight 75 g Weight 75 g Weight 35 g


Contact Blocks Operating diagram Page 33 Operating diagram Page 33 Operating diagram Page 33

2NC SMP1A02S••• SMP1A02S•••L SMP1A02SK


1NO + 2NC SMP1A12S••• SMP1A12S•••L
1NO + 1NC SMP1A11S••• SMP1A11S•••L SMP1A11SK
2NC with LED signalling SMP1A02L••• SMP1A02L•••L SMP1A02LK
1NO + 2NC with LED signalling SMP1A12L••• SMP1A12L•••L
1NO + 1NC with LED signalling SMP1A11L••• SMP1A11L•••L SMP1A11LK
Electrical connection: Replace the symbol “•••” with the lenght of the cable desired
010: Cable lenght 1m
020: Cable lenght 2m

Safety Magnetic Target M8 integrated connector M12 connector M12 connector


SMP1AMG
Actuation distance: 5 mm.

Weight 35 g Weight 50 g Weight 50 g


Contact Blocks Operating diagram Page 33 Operating diagram Page 33 Operating diagram Page 33

2NC SMP1A02SKL SMP1A02S001M SMP1A02S001ML


1NO + 2NC SMP1A12S001M SMP1A12S001ML
1NO + 1NC SMP1A11SKL SMP1A11S001M SMP1A11S001ML
2NC with LED signalling SMP1A02LKL SMP1A02L001M SMP1A02L001ML
1NO + 2NC with LED signalling SMP1A12L001M SMP1A12L001ML
1NO + 1NC with LED signalling SMP1A11LKL SMP1A11L001M SMP1A11L001ML

34
Safety Magnetic Sensors
SMP2- Polymeric housing - IP67
Safety Magnetic Target Cable connection Cable connection M8 integrated connector
SMP2AMG
Actuation distance: 5 mm.

Safety Magnetic Target


SMP2BMG
Actuation distance: 8 mm.

Weight 90 g Weight 90 g Weight 55 g


Contact Blocks Operating diagram Page 33 Operating diagram Page 33 Operating diagram Page 33

2NC SMP2A02S••• SMP2A02S•••L SMP2A02SK


1NO + 2NC SMP2A12S••• SMP2A12S•••L
1NO + 1NC SMP2A11S••• SMP2A11S•••L SMP2A11SK
2NC with LED signalling SMP2A02L••• SMP2A02L•••L SMP2A02LK
1NO + 2NC with LED signalling SMP2A12L••• SMP2A12L•••L
1NO + 1NC with LED signalling SMP2A11L••• SMP2A11L•••L SMP2A11LK
Electrical connection: Replace the symbol “•••” with the lenght of the cable desired
010: Cable lenght 1m
020: Cable lenght 2m

M8 integrated connector M12 connector M12 connector


Safety Magnetic Target
SMP2AMG
Actuation distance: 5 mm.

Safety Magnetic Target


SMP2BMG
Actuation distance: 8 mm.

Weight 55 g Weight 70 g Weight 70 g


Contact Blocks Operating diagram Page 33 Operating diagram Page 33 Operating diagram Page 33

2NC SMP2A02SKL SMP2A02S001M SMP2A02S001ML


1NO + 2NC SMP2A12S001M SMP2A12S001ML
1NO + 1NC SMP2A11SKL SMP2A11S001M SMP2A11S001ML
2NC with LED signalling SMP2A02LKL SMP2A02L001M SMP2A02L001ML
1NO + 2NC with LED signalling SMP2A12L001M SMP2A12L001ML
1NO + 1NC with LED signalling SMP2A11LKL SMP2A11L001M SMP2A11L001ML

35
Safety devices
Safety modules
Applications
Safety devices MS series are modules for emergency stop which have been developed for safety applications up to SIL 3 (EN 62061) and up to PLe
(EN ISO 13849-1). They are suitable for the control of limit switches for safety gates and of safety magnetic sensors.
• 1 or 2 channels input
• Manual / Automatic Start
• 3NO safety contacts + 1NC contact for signalling
• Suitable for use with electromecanic devices (limit switches and safety sensors) and with optical barriers

They comply with the requirements of European Directives (Low Voltage, Machines and Electromagnetic Compatibility) and are conform to European and international
standards.

Description
The polymeric housing for DIN rail mounting has a degree of protection IP40 (IP20 on terminal blocks) and it has standard dimensions 22.5 x 114 mm.

Casing
• Technopolymer IP40 (IP20 on terminal blocks)
• Standard dimension 22,5 x 114 mm.

Electrical connection:
• IP20 terminal blocks
• 1 or 2 x 0,75... 1,5 mm2

Output contacts
• 3NO safety contacts +1NC signalling contact
LED indicators for status, supply and diagnostic
• Power
• Channel 1
• Channel 2
DIN rail mounting

Symbols Example: MS1A31 – 024


Structure: MS1A31 –
Tensione di alimentazione:
024: 24V AC/DC
120: 120V AC
230: 230V AC

Dimensions (mm) Electrical connection


A1-A2: Supply voltage
S11: +24 V output
13 23 33 41 S12: Input Channel 1 (to S11 or +24V)
A1 S11 S52 S12 S22: Input channel 2 (to S21 or GND)
S52: Input Channel 2 (to S11 or +24V)
S21: GND
S34: Manual/automatic start input
13-14: Safety NO output contact
23-24: Safety NO output contact
33-34: Safety NO output contact
S21 S22 S34 A2 41-42: NC output contact for signalling

Cross section of the conductors: 0,2...2,5 mm2 (24...12 AWG)


14 24 34 42 Torque: 0,5 Nm (0,6 Nm max)

36
Safety devices
Safety modules - Technical Data
MS Series
Standards EN60947-1, EN60947-5-1, EN61000-6-2, EN61000-4, EN61326-3-1,
EN60204-1, EN ISO 13849-1, EN ISO 12100-1, EN ISO 12100-2
EN62061, EN1037, EN60664-1, EN60529
Directives 2006/95/CE low voltage
2006/42/CE machinery
2004/108/CE electromagnetic
Certifications - Approvals CE - IMQ
Air temperature near the device
– during operation °C – 25 ... + 55
– for storage °C – 25 ... + 55
Protection against electrical shocks (acc. to IEC 60536) Class II
Degree of protection (according to IEC 60529 and EN 60529) Casing IP40 - Terminal blocks IP20
Pollution degree 3 external, 2 internal
Safety integrity level (Sil CL) (according to EN IEC 62061) Up to Sil 3
Performance level (PL) (according to EN ISO 13849-1) Up to PLe
Safety category (according to EN ISO 13849-1) Up to Cat 4
Mechanical durability 10 millions of operations
Electrical durability 100.000 operations
MTTFd 218 (for 24 Vac/dc) / 147 (for 120 Vac and 230 Vac)
Diagnostic coverage H
PFHd 4,58 E-10 (for 24 Vac/dc) / 6,61 E-10 (for 120 Vac and 230 Vac)

Electrical Data
Rated insulation voltage Ui (acc. to IEC/EN 60947-1) 250 V (degree of pollution 3)
Rated impulse withstand voltage Uimp (acc. to IEC/EN 60947-1) 4 kV
Power supply
Rated operating voltage UN (±15%) 24 Vac/dc (10% max residual riple in DC) - 120 Vac - 230 Vac
Rated power consumption max 5 VA (ac) - max 2 W (dc)
Control circuit
Protection against short circuits Resistance PTC with intervention operating time >100ms, reset time >3s - Ih=0,5A
Input max resistance 50Ω
Input max current 30mA

Output circuit
Utilization categories (according to EN 60947-1) AC 15, Ue = 230 V, Ie = 3 A / DC 13, Ue = 24 V, Ie = 6 A (6 oper/minute)
Max switching voltage 240 Vac / 300 Vdc
Switching current range (per contact) min 10 mA - max 6A (external protection fuse 6A F type)
Conventional free air thermal current Ith 6A (max current sum: 64A2)
Max contact resistance 100 mΩ

Example of connection
with safety magnetic sensors

37
Safety Limit Switches
Safety Limit Switches with rope

W02: Simultaneous Y+Y


slow action
2NC K96 K9000 K9300 K9800 K9200
Pull wire without reset for simple stop Pull wire with reset for emergency stop
X11: Slow action Zb
break before make
1NO+1NC

X12P: Slow action Y+Y+X


break before make
1NO+2NC

X21P: Slow action Y+X+X


break before make
2NO+1NC

W03P: Simultaneous Y+Y+Y


SM_K series (Metal) SDM_K series (Metal)
slow action
3NC

K97 K9100
X12: Slow action Y+Y+X
break before make Pull wire without reset for simple stop
1NO+2NC

X21: Slow action Y+X+X Adapter G Type


break before make
2NO+1NC

W03: Simultaneous Y+Y+Y


slow action
K9500 K9900 K9400
3NC
Pull wire with reset for emergency stop

Contact blocks
Type: double break, electrically separated
SBM_K series SCM_K series
Approvals: UL 508 / CSA C22-2 n. 14
(Aluminium) (Aluminium)

38
Safety Limit Switches
Safety Limit Switches with rope - Description
Applications
Easy to use, the limit switches for safety applications with rope for simple and emergency stop offer specific qualities:
• Capability for strong current switching (conventional thermal current 10 A).
• Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol ).
• Electrically separated contacts.
• Precision on operating positions (consistency).
• Immunity to electromagnetic disturbances.
The use of the Comepi pull wire safety switches allows you to create perimeter protections of the machines, thus reducing the need to install
sever emergency stop stations in different points of the machine. They comply with the requirements of European Directives (Low Voltage and Machines
Directive) and are conform to European and international standards.

Description
SM/SDM series are made of zinc alloy (zamack). SBM/SCM series are realized in aluminium material, therefore they are mechanically more resistant and three
times lighter than the ones in zinc alloy. All metal limit switches have a degree of protection IP66.

Casing Operating heads:


• 30 mm. width with standardized dimensions acc. to EN 50047 • Streight
• 50 mm. width • 90° right
• 40 mm. width with standardized dimensions acc. to EN 50041 • 90° left
• 60 mm. width

Reset:
Mounting the casing • Manual reset button for emergency stop
• 2 x M4 screws on top part for 30 mm. width
• 2 or 4 x M4 screws on top part for 50 mm. width
• 2 or 4 x M5 screws on top part for 40 mm. width
• 2 x M5 screws on top part for 60 mm. width Cover:
• 3 screws for 30 mm. casing
• 2 screws for 40 mm. casing
• 4 screws for 50 and 60 mm. casing
Contact Block:
• Positive opening operation
• Slow action contacts
• Contacts are electrically separated

Connecting terminals:
• Block of 2 contacts: M3.5 (+, –) pozidriv 2 screw Electrical connection:
• Block of 3 contacts: M3 (+, –) screw • 1 x cable gland for SM/SBM series
• Screw head with captive cable clamp • 3 x cable gland for SBM/SCM series
• Markings conform with IEC 60947-1, IEC 60947-5-1 standard

Symbols Example: SD M 1 K 10 X 1 1
Structure: M K
Casing width:
S = 30 mm width + 1 cable inlet Contact block
SB = 40 mm width + 1 cable inlet
SC = 60 mm width + 3 cable inlets
11: 1 NO + 1 NC contacts
SD = 50 mm width + 3 cable inlets
02: 2 NC contacts
12P: 1 NO + 2 NC contacts
M: Metal (SM, SDM) / Aluminium (SBM, SCM) casing 21P: 2 NO + 1 NC contacts
03P: 3 NC contacts
Electrical connection Only for SBM, SCM series:
1: cable inlets for PG13.5 cable gland 12: 1 NO + 2NC contacts
2: cable inlets for 1/2 NPT cable gland 21: 2 NO + 1 NC contacts
3: cable inlets for PG11 cable gland (only for SM and SDM series) 03: 3 NC contacts
4: cable inlets for M16 x 1,5 cable gland (only for SM and SDM series)
5: cable inlets for M20 x 1,5 cable gland
W: Slow action (contact dependent)
Operating heads: X: Slow action non-overlapping late make
codes 96, 9000, 9300, 9800, 9200, 97, 9100, 9500, 9900, 9400

39
Safety Limit Switches
Safety Limit Switches with rope - Technical Data
SM / SBM / SCM / SDM Series
Standards IEC 60947-5-1, EN 60947-5-1
EN 60947-5-5 (models with reset)
Certifications - Approvals UL - CSA - IMQ - EAC - CCC
Air temperature near the device
– during operation °C – 25 ... + 70
– for storage °C – 30 ... + 80
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 61140) Class I
Degree of protection (according to IEC 60529 and EN 60529) IP 66

Electrical Data
Rated insulation voltage Ui
- according to IEC 60947-1 and EN 60947-1 500 V (degree of pollution 3) (400 V for contacts type Z02, X12P, X21P, W03P)
- according to UL 508 and CSA C22-2 n° 14 A 600, Q 600 (A 300, Q 300 for SM/SDM series and contacts type X12P, X21P, W03P)
Rated impulse withstand voltage Uimp
(according to IEC 60947-1 and EN 60947-1) kV 6
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 10
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 10
Rated operational current
Ie / AC-15 (according to IEC 60947-5-1) 24 V - 50/60 Hz A 10
120 V - 50/60 Hz A 6
400 V - 50/60 Hz A 4 (1.8A for contacts type X12, X21, W03)
Ie / DC-13 (according to IEC 60947-5-1) 24 V - d.c. A 6 (2.8A for contacts type X12, X21, W03)
125 V - d.c. A 0.55
250 V - d.c. A 0.4 (0.27A for contacts type X12, X21, W03)
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts m⍀ 25
Connecting terminals M3.5 (+, –) pozidriv 2 screw with cable clamp (M3 for 3 poles contacts type)
Terminal for protective conductor M3.5 (+, –) pozidriv 2 screw with cable clamp
Connecting capacity 1 or 2 x mm2 0.75 ... 2.5 (0.34... 1.5 for 3 poles contacts type)
Terminal marking According to IEC 60947-5-1
Mechanical durability 500.000 operations
Electrical durability (according to IEC 60947-5-1) Utilization categories AC-15 and DC-13 (Load factor of 0.5 according to curves below)
B10d = 1.000.000 cycles

AC-15 - Snap action AC-15 - Slow action

DC-13 Snap action Slow action

Power breaking for a durability


of 5 million operating cycles
Voltage 24 V 9.5 W 12 W
Voltage 48 V 6.8 W 9W
Voltage 110 V 3.6 W 6W

• Ordering details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 42 - 45


• Additional Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 61

40
Safety Limit Switches
Safety Limit Switches with rope - Technical Data
Technical data approved by IMQ Technical data approved by UL
Standards Devices conform with international IEC 60947-5-1 Standards Devices conform with UL 508
and European EN 60947-5-1 standards
Degree of protection IP 66 Contact blocks type Z11, X11, Y11, W02 and Z02
Rated insulation voltage Ui 500 V (degree of pollution 3) Utilization categories A600, Q600
(400 V for contacts type Z02, X12P, X21P, W03P) (A300, Q300 when installed in SM/SDM series)
Rated impulse withstand voltage Uimp 6 kV Contact blocks type X12, X21, W03
Utilization categories A600, Q600
Conventional free air thermal current Ith 10 A
Short-circuit protection - gG (gl) type fuses 10 A Contact blocks type X12P, X21P and W03P
Rated operational current Utilization categories A300, Q300
Ie / AC-15 24 V - 50/60 Hz 10 A Use 60/75°C copper (Cu) conductor only. Wire rages 14-18 AWG stranded or solid. The terminal tight-
400 V - 50/60 Hz 4 A (1.8A for contacts type X12, X21, W03) ening torque of 7 lbs-in / 0.78 Nm. Suitable for conduit connection only with use of adapter sleeve op-
Ie / DC-13 24 V - d.c. 6 A (2.8A for contacts type X12, X21, W03) tionally provided or recommended by the manufacturer.
125 V - d.c. 0,55 A
250 V - d.c. 0.4 A (0.27A for contacts type X12, X21, W03) For the complete list of approved products, contact our technical department

Implementation

Operating head orientation Examples of applications


The head can be rotated each 90°.
Recommended tightening torque 0,5 Nm (max 0,8 Nm).

Hand actuation

Foot actuation

41
Safety Limit Switches SM/SDM_K
Pull wire with reset for emergency stop - Metal casing - IP66
Electrical connection: K9300 Pull wire with reset K9800 Pull wire with reset K9200 Pull wire with reset
Replace the symbol “•” with for emergency stop for emergency stop for emergency stop
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. forces Initial 65N, Final 85N (95N ) Min. forces Initial 60N, Final 80N (90N ) Min. forces Initial 65N, Final 85N (95N )
Weight 275 g Weight 230 g Weight 275 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SM•K9300X11 SM•K9800X11 SM•K9200X11


W02 (2NC) SM•K9300W02 SM•K9800W02 SM•K9200W02
X12P (1NO+2NC) SM•K9300X12P SM•K9800X12P SM•K9200X12P
X21P (2NO+1NC) SM•K9300X21P SM•K9800X21P SM•K9200X21P
W03P (3NC) SM•K9300W03P SM•K9800W03P SM•K9200W03P

K9300 Pull wire with reset K9800 Pull wire with reset K9200 Pull wire with reset
for emergency stop for emergency stop for emergency stop

Min. forces Initial 65N, Final 85N (95N ) Min. forces Initial 60N, Final 80N (90N ) Min. forces Initial 65N, Final 85N (95N )
Weight 365 g Weight 320 g Weight 365 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SDM•K9300X11 SDM•K9800X11 SDM•K9200X11


W02 (2NC) SDM•K9300W02 SDM•K9800W02 SDM•K9200W02
X12P (1NO+2NC) SDM•K9300X12P SDM•K9800X12P SDM•K9200X12P
X21P (2NO+1NC) SDM•K9300X21P SDM•K9800X21P SDM•K9200X21P
W03P (3NC) SDM•K9300W03P SDM•K9800W03P SDM•K9200W03P

42
Safety Limit Switches SBM/SCM_K
Pull wire with reset for emergency stop - Metal casing - IP66
Electrical connection: K9500 Pull wire with reset K9900 Pull wire with reset K9400 Pull wire with reset
Replace the symbol “•” with for emergency stop for emergency stop for emergency stop
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
5: Cable gland M20 x 1,5

Min. forces Initial 150N, Final 215N (230N ) Min. forces Initial 120N, Final 160N (170N ) Min. forces Initial 150N, Final 215N (230N )
Weight 320 g Weight 250 g Weight 320 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SBM•K9500X11 SBM•K9900X11 SBM•K9400X11


W02 (2NC) SBM•K9500W02 SBM•K9900W02 SBM•K9400W02
X12 (1NO+2NC) SBM•K9500X12 SBM•K9900X12 SBM•K9400X12
X21 (2NO+1NC) SBM•K9500X21 SBM•K9900X21 SBM•K9400X21
W03 (3NC) SBM•K9500W03 SBM•K9900W03 SBM•K9400W03

K9500 Pull wire with reset K9900 Pull wire with reset K9400 Pull wire with reset
for emergency stop for emergency stop for emergency stop

Min. forces Initial 150N, Final 215N (230N ) Min. forces Initial 120N, Final 160N (170N ) Min. forces Initial 150N, Final 215N (230N )
Weight 345 g Weight 275 g Weight 345 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SCM•K9500X11 SCM•K9900X11 SCM•K9400X11


W02 (2NC) SCM•K9500W02 SCM•K9900W02 SCM•K9400W02
X12 (1NO+2NC) SCM•K9500X12 SCM•K9900X12 SCM•K9400X12
X21 (2NO+1NC) SCM•K9500X21 SCM•K9900X21 SCM•K9400X21
W03 (3NC) SCM•K9500W03 SCM•K9900W03 SCM•K9400W03

43
SM/SDM_K
Pull wire without reset for simple stop - Metal casing - IP66
Electrical connection: K96 Pull wire without reset K9000 Pull wire without reset
Replace the symbol “•” with for simple stop for simple stop
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. forces Initial 60N, Final 80N (90N ) Min. forces Initial 65N, Final 85N (95N )
Weight 220 g Weight 265 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SM•K96X11 SM•K9000X11


W02 (2NC) SM•K96W02 SM•K9000W02
X12P (1NO+2NC) SM•K96X12P SM•K9000X12P
X21P (2NO+1NC) SM•K96X21P SM•K9000X21P
W03P (3NC) SM•K96W03P SM•K9000W03P

K96 Pull wire without reset K9000 Pull wire without reset
for simple stop for simple stop

Min. forces Initial 60N, Final 80N (90N ) Min. forces Initial 65N, Final 85N (95N )
Weight 310 g Weight 355 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SDM•K96X11 SDM•K9000X11


W02 (2NC) SDM•K96W02 SDM•K9000W02
X12P (1NO+2NC) SDM•K96X12P SDM•K9000X12P
X21P (2NO+1NC) SDM•K96X21P SDM•K9000X21P
W03P (3NC) SDM•K96W03P SDM•K9000W03P

44
SBM/SCM_K
Pull wire without reset for simple stop - Metal casing - IP66
Electrical connection: K97 Pull wire without reset for simple stop K9100 Pull wire without reset
Replace the symbol “•” with for simple stop
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
5: Cable gland M20 x 1,5

Min. forces Initial 120N, Final 160N (170N ) Min. forces Initial 150N, Final 215N (230N )
Weight 240 g Weight 310 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SBM•K97X11 SBM•K9100X11


W02 (2NC) SBM•K97W02 SBM•K9100W02
X12 (1NO+2NC) SBM•K97X12 SBM•K9100X12
X21 (2NO+1NC) SBM•K97X21 SBM•K9100X21
W03 (3NC) SBM•K97W03 SBM•K9100W03

K97 Pull wire without reset for simple stop K9100 Pull wire without reset
for simple stop

Min. forces Initial 120N, Final 160N (170N ) Min. forces Initial 150N, Final 215N (230N )
Weight 265 g Weight 335 g
Contact Blocks Operating diagram Page 61 Operating diagram Page 61

X11 (1NO+1NC) SCM•K97X11 SCM•K9100X11


W02 (2NC) SCM•K97W02 SCM•K9100W02
X12 (1NO+2NC) SCM•K97X12 SCM•K9100X12
X21 (2NO+1NC) SCM•K97X21 SCM•K9100X21
W03 (3NC) SCM•K97W03 SCM•K9100W03

45
Safety Limit Switches Accessories
Safety Limit Switches with rope - Accessories
Stay Bolt Rope Clamp Rope eye Rope ø 5mm

24 7
11

22 7
83

14 5.5
59

24
Code Length
M8 FUN05M010 10m

35
FUN05M015 15m
22 11
FUN05M020 20m
Code Code Code FUN05M025 25m
OCC 08 MOR 05 RED 05 FUN05M102 102m

Code Description Code Description


SLS-FX1 Hook stay bolt SLS-FX2 Fixing clamp

Code Description Code Description


SLS-FX3 Stay bolt SLS-M1 Spring for SM, SDM series

Code Description
SLS-M2 Spring for SBM, SCM series

46
Safety Limit Switches
Safety Limit Switches with rope
Installation instructions
In order to obtain the correct operation
of the device, please follow the following
instructions.
1. Install the switch and secure the fixed
end of the rope. Apply tension to the ex-
tent the green O-ring is visible and the
bottom is flush with the end of the red
housing. (Fig. 1).

2. Pull the reset pommel in order to close the safety contacts


of the limit switch.
3. The contacts inside the limit switch will change their po-
sition whenever the rope is pulled or loose its tension.
4. Check the correct operation of the rope switch before you
start the machine and periodically.
Performing the role of worker protection, improper installation
or tampering with safety devices can cause serious injury to
persons.
The installation must therefore be performed in accordance
with local legislation and only by authorized personnel.
For any question about CE declaration of conformity or for
any information and assistance, please contact our technical
department

47
Safety Limit Switches
Safety Limit Switches with reset

R11 R13 R31 R32 R38 R41


Steel plunger Steel plunger Steel plunger Steel plunger Steel plunger Lever with
with reset with nylon roller with nylon roller with nylon roller with nylon roller nylon roller
with reset with reset with reset with reset with reset

Z02: Snap action Y+Y


2NC

Z11: Snap action Zb


1NO+1NC

W02: Simultaneous Y+Y


slow action
2NC

AP_R series (Plastic) DP_R series (Plastic)


X11: Slow action Zb
break before make
1NO+1NC

Y11: Slow action Zb


make before break
1NO+1NC

X12P: Slow action Y+Y+X


break before make
1NO+2NC
AM_R series (Metal) DM_R series (Metal)
X21P: Slow action Y+X+X
break before make
2NO+1NC

W03P: Simultaneous Y+Y+Y


slow action
3NC

Contact blocks
Type: double break, electrically
separated
Approvals: UL 508 / CSA C22-2 n. 14

48
Safety Limit Switches
Safety Limit Switches with reset - Description
Applications
Easy to use, the limit switches for safety applications with latch and manual reset offer specific qualities:
• Visible operation (fault memorisation).
• Capability for strong current switching (conventional thermal current 10 A).
• Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol ).
• Electrically separated contacts.
• Precision on operating positions (consistency).
• Immunity to electromagnetic disturbances.
These specific features make the limit switches ideal for detection and monitoring of faults in hoisting machines, electric lifts, freight elevators,
escalators, conveyor belts, etc. They comply with the requirements of European Directives (Low Voltage and Machines Directives) and are conform to European
and international standards.

Description
Limit switches with latch and manual reset are equipped with operating heads with plunger, roller plunger or roller lever, used to detect rectilinear or angular mo-
vements. AP/DP series are made of fibre-glass reinforced UL-V0 thermoplastic material, they offer double insulation and a degree of protection IP65.
AM/DM series are made of zinc alloy (zamack) and have a degree of protection IP66. Limit switches with latch and manual reset are equipped with 1NO+1NC, 2NC,
1NO+2NC, 2NO+1NC or 3NC contact blocks with positive opening operation of the "N.C." contact(s). After actuating the control device and overshooting the latching
point, the N.C. safety contact(s) remain in the open position. Return to the initial operating state takes place by voluntary action on the reset button.

Casing A variety of operating heads:


• 30 mm. width with standardized dimensions acc. to EN 50047 • Metal plunger
• 50 mm. width with standardized dimensions • Metal plunger and nylon roller
• Nylon roller lever

Mounting the casing • Other levers available upon request


• 2 x M4 screws on top part for 30 mm. width
• 2 or 4 x M4 screws on top part for 50 mm. width
Reset:
• Manual reset button

Contact Block:
• Positive opening operation
• Snap action or slow action Cover:
• Contacts are electrically separated • 1 or 3 screws for 30 mm. casing
• 1 or 4 screws for 50 mm. casing

Connecting terminals: Electrical connection:


• Block of 2 contacts: M3.5 (+, –) pozidriv 2 screw • 1 x cable gland for AP and AM series
• Block of 3 contacts: M3 (+, –) screw • 2 x cable gland for DP series
• Screw head with captive cable clamp • 3 x cable gland for DM series
• Markings conform with IEC 60947-1, IEC 60947-5-1 standard

Symbols Example: A P 1 R 41 Z 1 1
Structure: R

Casing width: Contact block


A = 30 mm width + 1 cable inlet
D = 50 mm width + 2 cable inlets (DP series)
or 3 cable inlets (DM series) 11: 1 NO + 1 NC contacts
02: 2 NC contacts
12P: 1 NO + 2 NC contacts
P: Plastic casing M: Metal casing 21P: 2 NO + 1 NC contacts
03P: 3 NC contacts
Electrical connection
1: cable inlets for PG13.5 cable gland
2: cable inlets for 1/2 NPT cable gland *
Z: Snap action
3: cable inlets for PG11 cable gland
W: Slow action (contact dependent)
4: cable inlets for M16 x 1,5 cable gland
X: Slow action non-overlapping late make
5: cable inlets for M20 x 1,5 cable gland
Y: Slow action overlapping early make

Manual reset version

Operating heads: codes 11-13-31-32-38-41


• Other levers available upon request

* In AP... and DP... series, the 1/2” NPT thread is obtained by the use of a plastic adapter (delivered not mounted).

49
Safety Limit Switches
Technical Data
AP / DP Series AM / DM Series
Standards IEC 60947-5-1
EN 60947-5-1
Certifications - Approvals UL - CSA - IMQ - EAC - CCC
Air temperature near the device
– during operation °C – 25 ... + 70
– for storage °C – 30 ... + 80
Mounting positions All positions are authorised
Protection against electrical shocks (acc. to IEC 61140) Class II Class I
Degree of protection (according to IEC 60529 and EN 60529) IP 65 IP 66

Electrical Data
Rated insulation voltage Ui
- according to IEC 60947-1 and EN 60947-1 500 V (degree of pollution 3) (400 V for contacts type Z02, X12P, X21P, W03P)
- according to UL 508 and CSA C22-2 n° 14 A 600, Q 600 (A 300, Q 300 for AM/DM series and contacts type X12P, X21P, W03P)
Rated impulse withstand voltage Uimp
(according to IEC 60947-1 and EN 60947-1) kV 6
Conventional free air thermal current Ith
(according to IEC 60947-5-1) ␪ < 40 °C A 10
Short-circuit protection
Ue < 500 V a.c. - gG (gl) type fuses A 10
Rated operational current
Ie / AC-15 (according to IEC 60947-5-1) 24 V - 50/60 Hz A 10
120 V - 50/60 Hz A 6
400 V - 50/60 Hz A 4
Ie / DC-13 (according to IEC 60947-5-1) 24 V - d.c. A 6
125 V - d.c. A 0.55
250 V - d.c. A 0.4
Switching frequency Cycles/h 3600
Load factor 0.5
Resistance between contacts m⍀ 25
Connecting terminals M3.5 (+, –) pozidriv 2 screw with cable clamp (M3 for 3 poles contacts type)
Terminal for protective conductor – M3.5 (+, –) pozidriv 2 screw with cable clamp
Connecting capacity 1 or 2 x mm2 0.75 ... 2.5 (0.34... 1.5 for 3 poles contacts type)
Terminal marking According to IEC 60947-5-1
Mechanical durability 1 million of operations
Electrical durability (according to IEC 60947-5-1) Utilization categories AC-15 and DC-13 (Load factor of 0.5 according to curves below)
B10d = 2.000.000 cycles

AC-15 - Snap action AC-15 - Slow action

DC-13 Snap action Slow action

Power breaking for a durability


of 5 million operating cycles
Voltage 24 V 9.5 W 12 W
Voltage 48 V 6.8 W 9W
Voltage 110 V 3.6 W 6W

• Ordering details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 52 - 55


• Additional Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59

50
Safety Limit Switches
Technical Data
Technical data approved by IMQ Technical data approved by UL
Standards Devices conform with international IEC 60947-5-1 Standards Devices conform with UL 508
and European EN 60947-5-1 standards
Degree of protection IP 65 (AP/DP series) , IP 66 (AM/DM series) Contact blocks type Z11, X11, Y11, W02 and Z02
Rated insulation voltage Ui 500 V (degree of pollution 3) Utilization categories A600, Q600
(400V for type Z02, X12P, X21P, W03P) (A300, Q300 when installed in AM/DM series)
Rated impulse withstand voltage Uimp 6 kV
Contact blocks type X12P, X21P and W03P
Conventional free air thermal current Ith 10 A
Utilization categories A300, Q300
Short-circuit protection - gG (gl) type fuses 10 A Use 60/75°C copper (Cu) conductor only. Wire rages 14-18 AWG stranded or solid. The terminal tight-
Rated operational current ening torque of 7 lbs-in / 0.78 Nm. Suitable for conduit connection only with use of adapter sleeve op-
Ie / AC-15 24 V - 50/60 Hz 10 A tionally provided or recommended by the manufacturer.
400 V - 50/60 Hz 4A
Ie / DC-13 24 V - d.c. 6A
125 V - d.c. 0.55 A
250 V - d.c. 0.4 A
For the complete list of approved products, contact our technical department

Implementation

Operating head orientation Lever adjustment


The head can be rotated each 90°. The lever of the head model R41 can ber adjusted every 10° and round turned
Recommended tightening torque 0,5 Nm (max 0,8 Nm). in order to, obtain the maximum flexibility on the working plan
Recommended tightening torque 0,5 Nm (max 0,8 Nm).

51
Safety Limit Switches AP_R
Polymeric casing. Polymer head. 30 mm width. 1 cable inlet - IP65
Electrical connection: R11 Steel plunger with reset R13 Steel plunger with nylon roller R31 Steel plunger with nylon roller
Replace the symbol “•” with with reset with reset
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
(with adapter)
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating force 15 N (30N ) Min. actuating force 12 N (30N ) Min. actuating force 7 N (24N )
Weight 90 g Weight 90 g Weight 95 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) AP•R11Z11 AP•R13Z11 AP•R31Z11


X11 (1NO+1NC) AP•R11X11 AP•R13X11 AP•R31X11
Y11 (1NO+1NC) AP•R11Y11 AP•R13Y11 AP•R31Y11
W02 (2NC) AP•R11W02 AP•R13W02 AP•R31W02
Z02 (2NC) AP•R11Z02 AP•R13Z02 AP•R31Z02
X12P (1NO+2NC) AP•R11X12P AP•R13X12P AP•R31X12P
X21P (2NO+1NC) AP•R11X21P AP•R13X21P AP•R31X21P
W03P (3NC) AP•R11W03P AP•R13W03P AP•R31W03P

R32 Steel plunger with nylon roller R41 Lever with nylon roller
with reset with reset

Min. actuating force 7 N (24N ) Min. actuating torque 0,10 Nm (0,32 Nm )


Weight 95 g Weight 95 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) AP•R32Z11 AP•R41Z11


X11 (1NO+1NC) AP•R32X11 AP•R41X11
Y11 (1NO+1NC) AP•R32Y11 AP•R41Y11
W02 (2NC) AP•R32W02 AP•R41W02
Z02 (2NC) AP•R32Z02 AP•R41Z02
X12P (1NO+2NC) AP•R32X12P AP•R41X12P
X21P (2NO+1NC) AP•R32X21P AP•R41X21P
W03P (3NC) AP•R32W03P AP•R41W03P

52
Safety Limit Switches DP_R
Polymeric casing. Polymer head. 50 mm width. 2 cable inlets - IP65
Electrical connection: R11 Steel plunger with reset R13 Steel plunger with nylon roller R31 Steel plunger with nylon roller
Replace the symbol “•” with with reset with reset
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
(with adapter)
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating force 15 N (30N ) Min. actuating force 12 N (30N ) Min. actuating force 7 N (24N )
Weight 120 g Weight 120 g Weight 125 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) DP•R11Z11 DP•R13Z11 DP•R31Z11


X11 (1NO+1NC) DP•R11X11 DP•R13X11 DP•R31X11
Y11 (1NO+1NC) DP•R11Y11 DP•R13Y11 DP•R31Y11
W02 (2NC) DP•R11W02 DP•R13W02 DP•R31W02
Z02 (2NC) DP•R11Z02 DP•R13Z02 DP•R31Z02
X12P (1NO+2NC) DP•R11X12P DP•R13X12P DP•R31X12P
X21P (2NO+1NC) DP•R11X21P DP•R13X21P DP•R31X21P
W03P (3NC) DP•R11W03P DP•R13W03P DP•R31W03P

R38 Steel plunger with nylon roller R41 Lever with nylon roller
with reset with reset

Min. actuating force 7 N (24N ) Min. actuating torque 0,10 Nm (0,32 Nm )


Weight 125 g Weight 125 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) DP•R38Z11 DP•R41Z11


X11 (1NO+1NC) DP•R38X11 DP•R41X11
Y11 (1NO+1NC) DP•R38Y11 DP•R41Y11
W02 (2NC) DP•R38W02 DP•R41W02
Z02 (2NC) DP•R38Z02 DP•R41Z02
X12P (1NO+2NC) DP•R38X12P DP•R41X12P
X21P (2NO+1NC) DP•R38X21P DP•R41X21P
W03P (3NC) DP•R38W03P DP•R41W03P

53
Safety Limit Switches AM_R
Metal casing. Polymer head. 30 mm width. 1 cable inlet - IP66
Electrical connection: R11 Steel plunger with reset R13 Steel plunger with nylon roller R31 Steel plunger with nylon roller
Replace the symbol “•” with with reset with reset
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating force 15 N (30N ) Min. actuating force 12 N (30N ) Min. actuating force 7 N (24N )
Weight 185 g Weight 185 g Weight 190 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) AM•R11Z11 AM•R13Z11 AM•R31Z11


X11 (1NO+1NC) AM•R11X11 AM•R13X11 AM•R31X11
Y11 (1NO+1NC) AM•R11Y11 AM•R13Y11 AM•R31Y11
W02 (2NC) AM•R11W02 AM•R13W02 AM•R31W02
Z02 (2NC) AM•R11Z02 AM•R13Z02 AM•R31Z02
X12P (1NO+2NC) AM•R11X12P AM•R13X12P AM•R31X12P
X21P (2NO+1NC) AM•R11X21P AM•R13X21P AM•R31X21P
W03P (3NC) AM•R11W03P AM•R13W03P AM•R31W03P

R32 Steel plunger with nylon roller R41 Lever with nylon roller
with reset with reset

Min. actuating force 7 N (24N ) Min. actuating torque 0,10 Nm (0,32 Nm )


Weight 190 g Weight 190 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) AM•R32Z11 AM•R41Z11


X11 (1NO+1NC) AM•R32X11 AM•R41X11
Y11 (1NO+1NC) AM•R32Y11 AM•R41Y11
W02 (2NC) AM•R32W02 AM•R41W02
Z02 (2NC) AM•R32Z02 AM•R41Z02
X12P (1NO+2NC) AM•R32X12P AM•R41X12P
X21P (2NO+1NC) AM•R32X21P AM•R41X21P
W03P (3NC) AM•R32W03P AM•R41W03P

54
Safety Limit Switches DM_R
Metal casing. Polymer head. 50 mm width. 3 cable inlets - IP66
Electrical connection: R11 Steel plunger with reset R13 Steel plunger with nylon roller R31 Steel plunger with nylon roller
Replace the symbol “•” with with reset with reset
the number of the thread desired
1: Cable gland PG 13.5
2: Cable gland 1/2” NPT
3: Cable gland PG 11
4: Cable gland M16 x 1,5
5: Cable gland M20 x 1,5

Min. actuating force 15 N (30N ) Min. actuating force 12 N (30N ) Min. actuating force 7 N (24N )
Weight 245 g Weight 245 g Weight 250 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) DM•R11Z11 DM•R13Z11 DM•R31Z11


X11 (1NO+1NC) DM•R11X11 DM•R13X11 DM•R31X11
Y11 (1NO+1NC) DM•R11Y11 DM•R13Y11 DM•R31Y11
W02 (2NC) DM•R11W02 DM•R13W02 DM•R31W02
Z02 (2NC) DM•R11Z02 DM•R13Z02 DM•R31Z02
X12P (1NO+2NC) DM•R11X12P DM•R13X12P DM•R31X12P
X21P (2NO+1NC) DM•R11X21P DM•R13X21P DM•R31X21P
W03P (3NC) DM•R11W03P DM•R13W03P DM•R31W03P

R38 Steel plunger with nylon roller R41 Lever with nylon roller
with reset with reset

Min. actuating force 7 N (24N ) Min. actuating torque 0,10 Nm (0,32 Nm )


Weight 250 g Weight 250 g
Contact Blocks Operating diagram Page 59 Operating diagram Page 59

Z11 (1NO+1NC) DM•R38Z11 DM•R41Z11


X11 (1NO+1NC) DM•R38X11 DM•R41X11
Y11 (1NO+1NC) DM•R38Y11 DM•R41Y11
W02 (2NC) DM•R38W02 DM•R41W02
Z02 (2NC) DM•R38Z02 DM•R41Z02
X12P (1NO+2NC) DM•R38X12P DM•R41X12P
X21P (2NO+1NC) DM•R38X21P DM•R41X21P
W03P (3NC) DM•R38W03P DM•R41W03P

55
Safety Devices
General Technical Data, Specifications, Directives and Standards
The Comepi products listed in this catalogue are developed and manufactured according to the rules set out in IEC international publications and EN European
standard.

Specifications
• International Specifications
The International Electrotechnical Commission, IEC, which is part of the International Standards Organization, ISO, publishes IEC publications which act as a basis
for the world market.
• European Specifications
The European Committee for Electrotechnical Standardisation (CENELEC) publishes EN standards for low voltage industrial apparatus.
These European standards differ very little from IEC international standards and use a similar numbering system. The same is true of national standards. Contra-
dicting national standards are withdrawn.
• Harmonised European Specifications
The European Committees for Standardisation (CEN and CENELEC) publish EN standards relating to safety of machinery.
• Specifications in Canada and the USA
These are equivalent, but differ markedly from IEC, UTE, VDE and BS specifications.
UL Underwriters Laboratories (USA)
CSA Canadian Standards Association (Canada)

Remark concerning the label issued by the UL (USA). Two levels of acceptance between devices must be distinguished.
“Recognized” Authorised to be included in equipment, if the equipment in question has been entirely mounted and wired by qualified personnel. They are not
valid for use as “General purpose products” as their possibilities are limited.
They bear the mark:
“Listed” Authorised to be included in equipment and for separate sale are “General purpose products” components in the USA.
They bear the mark:

European Directives
The guarantee of free movement of goods within the European Community assumes elimination of any regulatory differences between the member states. European
Directives set up common rules that are included in the legislation of each state while contracditory regulations are cancelled.

There are three main directives:


• Low Voltage Directive 2014/35/UE concerning electrical equipment from 50 to 1000 V a.c. and from 75 to 1500 V d.c.
This specifies that compliance with the requirements that is sets out is acquired once the equipment conforms to the standards harmonised at European level:
EN 60947-1 and EN-60947-5-1 for limit switches.
• Machines Directives - 2006/42/CE defining main safety and health requirements concerning design and manufacture of the machines and other equipment
including safety components in European Union countries.
• Electro
megnetic Compatibility Directive 2014/30/UE concerning all electrical devices likely to create electromagnetic disturbances.

Signification of CE marking:
CE marking must not be confused with a quality label.
CE marking placed on a product is proof of conformity with the European Devices concerning the product.
CE marking is part of an administrative procedure and guarantees free movement of the product within the European Community.

56
Safety Devices
General Technical Data, Specifications, Directives and Standards
Standards
• International Standards
IEC 60947-1 Low-voltage switchgear and controlgear - Part 1: General Rules (CEI EN 60947-1).
IEC 60947-5-1 Low-voltage switchgear and controlgear - Part 5: Control circuit devices and switching elements - Section 1: Electromechanical control circuit
devices (CEI EN 60947-5-1) - Chapter 3: Special requirements for control switches with positive opening operation.
IEC 60204-1 Electrical equipment on industrial machines - Part 1: General requirements (CEI EN 60204-1).
IEC 60204-2 Electrical equipment on industrial machines - Part 2: Item designation and examples of drawings, diagrams, tables and instructions.
IEC 60529 Degrees of protection provided by enclosure (IP code) (CEI EN 60529).

• European Standards
EN 50041 Low-voltage switchgear and controlgear for industrial use. Controlswitches. Position switches 42,5 x 80. Dimensions and characteristics.
EN 50047 Low-voltage switchgear and controlgear for industrial use. Control switches. Position switches 30 x 55. Dimensions and characteristics.
EN 60947-1 Low-voltage switchgear and controlgear - Part 1: General rules.
EN 60947-5-1 Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit device
EN 60947-5-5 Low-voltage switchgear and controlgear - Part 5-5: Control circuit devices and switching elements - Electrical emergency stop device with
mechanical latching function.

• American Standards
UL 508 Standard for Industrial Control Equipment
C22.2 NO. 14-13 Industrial control equipment.

• Chinese Standards
GB 14048.5 Low-voltage switchgear and controlgear - Part 5: Control circuit devices and switching elements.

57
Safety Devices
General Technical Data, Specifications, Directives and Standards
Double Insulation
Class II materials, according to IEC 536, are designed with double insulation. This measure consists in doubling the functional insulation with an additional layer of
insulation so as to eliminate the risk of electric shock and thus not having to protect elsewhere. No conductive part of "double insulated" material should be
connected to a protective conductor.

Positive Opening Operation


A control switch, with one or more break-contact elements, has a positive opening operation when the switch actuator ensures full contact opening of the break-
contact. For the part of travel that separates the contacts, there must be a positive drive, with no resilient member (e.g. springs), between the moving contacts and
the point of the actuator to which the actuating force is applied.
The positive opening operation does not deal with N.O. contacts.
Control switches with positive opening operation may be provided with either snap action or slow action contact elements. To use several contacts on the same
control switch with positive opening operation, they must be electrically separated from each other, if not, only one may be used.
Every control switch with positive opening operation must be indelibly marked on the outside with the symbol: .

Snap Action
Snap action contacts are characterised by a release position that is distinct from the operating position (differential travel). Snap breaking of moving contacts is
independent of the switch actuator's speed and contributes to regular electric performance even for slow switch actuator speeds.

State of rest Contact change Positive opening

Slow Action
Slow action contacts are characterised by a release position that is the same as the operating position. The switch actuator's speed directly conditions the travel
speed of contacts.

State of rest Completely closed

Contact shape according to IEC 947-5-1.


Change-over contact elements with 4 terminals must be indelibly marked with the corresponding Za or Zb symbol as in the diagrams below.

Contacts with the same polarity The 2 moving contacts are electrically separated

Utilization Category
AC-15: switching of electromagnetic loads of electromagnets using an alternating current (⬎72 VA).
DC-13: switching of electromagnets using a direct current.

Terminals
Limit switches with metal casings must have a terminal, for a protective conductor, that is placed inside the casing very close to the cable inlet and must be indelibly
marked.

Minimum Actuation Force/Torque


The minimum amount of force/torque that is to be applied to the switch actuator to produce a change in contact position.

Minimum Force/Torque to achieve Positive Opening Operation


The minimum amount of force/torque that is to be applied to the switch actuator to ensure positive opening operation of the N.C. contact.

58
Safety Devices
Plastic or Metal Casing - Travel and Operation Diagrams
Diagram for snap action contacts:

Diagram for non-overlapping slow


action contacts:

Diagram in millimetres Diagram in degrees

Po Free position: position of the switch actuator when CP Positive opening travel: minimum travel of the
no external force is exerted on it. switch actuator, from the free position, to ensure posi-
PA Operating position: position of the switch actuator, tive opening operation of the normally closed contact.
under the effect of force F1, when the contacts leave CA Latching travel: distance between the free posi- Note: for slow action contacts, C3 = 0, C1-1 = pre-travel
their initial free position. tions P0 and the latching point SA. of contact 21-22, C1-2 = pre-travel of contact 13-14
PP Positive opening position: position of the switch C2 Over-travel: distance between the operating posi-
actuator from which positive opening is ensured. tion PA and the max. travel position L.  Actuation
SA Latching point: point of no return of the switch ac- CL Max. travel: distance between the free position PO  Release
tuator beyond which the opened status of the NC con- and the max. travel position L.
tacts is maintained. Unlocking will only occur after C3 Differential travel (C1-C4): travel difference of Contact closed
deliberate action on the reset button. the switch actuator between the operating position PA Contact opened
L Max. travel position: maximum acceptable travel and the release position PR.  Positive opening operation
position of the switch actuator. C4 Release travel: distance between the release po- R Latching point SA
PR Release position: position of the switch actuator sition PR and the free position PO.
when the contacts return to their initial free position.
C1 Pre-travel: distance between the free position PO
and the operating position PA.

R11 R13 R31-R32 R38 R41


Steel plunger Steel plunger Steel plunger Steel plunger Lever with
with reset with nylon roller with nylon roller with nylon roller nylon roller
with reset with reset with reset with reset

Z11: Snap action


1NO+1NC

X11: Slow action


break before make
1NO+1NC
Y11: Slow action
make before break
1NO+1NC

W02: Simultaneous
slow action 2NC

Z02: Snap action


2NC

X12P: Slow action


break before make
1NO+2NC
X21P: Slow action
break before make
2NO+1NC

W03P: Simultaneous
slow action 3NC

59
Safety Devices
Plastic or Metal Casing - Travel and Operation Diagrams
Diagram for snap action contacts: Diagram for snap action contacts:

Diagram for non-overlapping slow Diagram for non-overlapping slow


action contacts: action contacts:

Po Free position: position of the switch actuator when and the operating position PA. Note: for slow action contacts, C3 = 0, C1-1 = pre-travel
no external force is exerted on it. CP Positive opening travel: minimum travel of the of contact 21-22, C1-2 = pre-travel of contact 13-14
PA Operating position: position of the switch actuator, switch actuator, from the free position, to ensure posi-
under the effect of force F1, when the contacts leave tive opening operation of the normally closed contact.
their initial free position. C2 Over-travel: distance between the operating posi-  Actuation
PP Positive opening position: position of the switch tion PA and the max. travel position L.
 Release
actuator from which positive opening is ensured. CL Max. travel: distance between the free position PO
L Max. travel position: maximum acceptable travel and the max. travel position L. Contact closed
position of the switch actuator under the effect of a C3 Differential travel (C1-C4): travel difference of Contact opened
force F1. the switch actuator between the operating position PA  Positive opening operation
PR Release position: position of the switch actuator and the release position PR.
when the contacts return to their initial free position. C4 Release travel: distance between the release po-
C1 Pre-travel: distance between the free position PO sition PR and the free position PO.

K10 K80 K3000-K4000 K5000 K61-K71-K72


Adjustable Fully turnable Adjustable Adjustable Adjustable
head 90° head head 90° head 90° head 90°

Z11: Snap action


1NO+1NC

X11: Slow action


break before make
1NO+1NC
Y11: Slow action
make before break
1NO+1NC

W02: Simultaneous
slow action 2NC

Z02: Snap action


2NC

X12P: Slow action


break before make
1NO+2NC
X21P: Slow action
break before make
2NO+1NC

W03P: Simultaneous
slow action 3NC

60
Safety Devices
Plastic or Metal Casing - Travel and Operation Diagrams
Po Free position: position of the switch actuator when CL Max. travel: distance between the starting position
no external force is exerted on it. O and the max. travel position L.
0 Starting position: position of the switch actuator, CL’ Travel between pre-tensioning position C0 and
under the effect of force F1. free position P0 in case of rope cut.
PP Positive opening position: position of the switch
actuator from which positive opening is ensured.
L Max. travel position: maximum acceptable travel
position of the switch actuator.  Actuation
C0 Ideal travel for pre-tensioning: distance between
 Release
the free position PO and the starting position O.
CP Positive opening travel: minimum travel of the Contact closed
switch actuator, from the starting position O, to ensure Contact opened
positive opening operation of the normally closed con-  Positive opening operation
tact.
R Latching point SA
CES, CES’ Travel for emeregency stop and latching
point.

K96 K9000 K9300 K9800 K9200


Pull wire without Pull wire without Pull wire with reset Pull wire with reset Pull wire with reset
reset for simple stop reset for simple stop for emergency stop for emergency stop for emergency stop

X11: Slow action


break before make
1NO+1NC

W02: Simultaneous
slow action 2NC

X12P: Slow action


break before make
1NO+2NC
X21P: Slow action
break before make
2NO+1NC

W03P: Simultaneous
slow action 3NC

K97 K9100 K9500 K9900 K9400


Pull wire without Pull wire without Pull wire with reset Pull wire with reset Pull wire with reset
reset for simple stop reset for simple stop for emergency stop for emergency stop for emergency stop

X11: Slow action


break before make
1NO+1NC

W02: Simultaneous
slow action 2NC

X12: Slow action


break before make
1NO+2NC
X21: Slow action
break before make
2NO+1NC

W03: Simultaneous
slow action 3NC

61
Safety Devices
Notes

62
Comepi all over the world
Argentina
Australia
Austria
Belgium
Brazil
Canada
Chile
Colombia
Denmark
Ecuador
Egypty
Finland
France
Germany
Great Britain

Greece
Iran
Ireland
Iceland
Israel
Italy
Malta
The Netherlands
Poland
Portugal
Peru
Spain
United States
South Africa
Sweden
Turkey
COMEPI srl
23899 Robbiate (Lecco) Italy
Via Novarino 9/L
Tel. +39 039 990 6408
CAT113-SC1017

Fax +39 039 990 6203


www.comepi.it
e-mail: comepi@comepi.it