Estun E200p Installation
Estun E200p Installation
(Version: V1.02)
E200P Installation Manual
Contents
Preface ........................................................................................................... 1
Chapter 1 Specification ............................................................................................. 3
1.1 Display ............................................................................................................. 3
1.2 Memory ............................................................................................................ 3
1.3 Electrical Specification..................................................................................... 3
Chapter 2 Installation and Wiring............................................................................. 5
2.1 Announcements before installation ................................................................. 5
2.2 Installation space and direction ....................................................................... 5
2.3 Installation environment .................................................................................. 5
2.4 Dimension ........................................................................................................ 6
2.5 Installation layout and Interface....................................................................... 7
2.5.1 Layout of rear panel .............................................................................................. 7
2.5.2 Definition of power interface .................................................................................. 7
2.5.3 Definition of input interface .................................................................................... 7
2.5.4 Definition of output interface.................................................................................. 8
2.5.5 Definition of encoder interface............................................................................... 8
2.5.6 Definition of communication interface ................................................................... 9
Chapter 3 Parameter Setting .................................................................................. 10
3.1 Home Page .................................................................................................... 10
3.2 System Parameter ......................................................................................... 13
3.3 X-axis Parameter ........................................................................................... 14
3.4 Y-axis Parameter ........................................................................................... 17
3.5 YV Setting ...................................................................................................... 18
3.6 Backup and Load........................................................................................... 20
Chapter 4 Diagnose ................................................................................................. 21
4.1 Home Page .................................................................................................... 21
4.2 Input Diagnose .............................................................................................. 22
4.3 Output Diagnose............................................................................................ 23
4.4 Keyboard Diagnose ....................................................................................... 24
4.5 FRAM Diagnose ............................................................................................ 25
4.6 ENC. Diagnose .............................................................................................. 26
4.7 LCD Diagnose ............................................................................................... 27
4.8 Factory Setting .............................................................................................. 28
Chapter 5 Commissioning ...................................................................................... 29
5.1 Preparation before commissioning ................................................................ 29
5.2 Procedure ...................................................................................................... 29
5.2.1 Parameter setting ................................................................................................ 29
5.2.2 Manual movement ............................................................................................... 30
5.2.3 Counting .............................................................................................................. 30
5.2.4 Retract................................................................................................................. 30
E200P Installation Manual
Preface
Synopsis
This document guides the operator how to install, configure and maintenance the
E200P press break numerical control device.
Chapter 2 guides the user how to install and wire, and describes the ports.
Intended Audience
This document is intended for the authorized and properly trained persons:
Device manufacturer: In the device production process, the people who diagnose
the device have the highest managing privileges.
Attention
Copy right is preserved by ESTUN. Do not add or delete part or all of the manual
content without ESTUN’s consent. Do not use part or all of manual content for the
third party’s design.
ESTUN preserves the right to modifying this manual in the event of function adding
or print error.
E200P device has the light protection function, but only works on the CLOSED
stage, it is unavailable on others stage.
1
E200P Installation Manual
Caution Sign
The following symbols with an adjoining safety advice or notice are used in this
document. You have to read the safety advices carefully and adhere them strictly!
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is
danger to life and health of individuals!
Hazard to individuals!
If you do not adhere the safety advice adjoining this symbol, there is
obvious hazard to individuals!
Note or pointer.
This symbol indicates information that contributes to better understanding.
2
E200P Installation Manual
Chapter 1 Specification
1.1 Display
LCD
Status light
1.2 Memory
Capable of storing 40 programs, each program includes 25 steps at most.
INPUT
Power 24VDC±10%
3
E200P Installation Manual
OUTPUT
Output type Open collector
Encoder
Support type complementary type / Voltage type
Input phase A, B, C
Output phase A, B, C
Communication
Interface CAN RS485 RS232
4
E200P Installation Manual
Grounding terminal of E200P digital control device must be grounded in correct way,
with low impedance lower than 0.3Ω.
Electrical components inside the digital device are very sensitive to static electricity,
therefore do not put foreign matters or make them fall to the inside of digital control
device or touch the control circuit.
Please install E200P digital control device in safe region. Avoid high temperature,
and direct sunlight, moisture and splash of oil drops or water.
Do not use this device in place of high temperature, moisture condensation, dust,
oil smoke, conductive dust, corrosive gas or flammable gas.
5
E200P Installation Manual
2.4 Dimension
The installation method is panel mounting. Installation dimension and drawings are
shown in Figure 2-1.
50.8
4-R3 45.5
194±0.2 42.5
146±0.2
182
134
6
E200P Installation Manual
1 2 3
Pin 1 2 3
1 2 3 4 5 6 7 8 9
1 I1 Step
2 I2 Press
3 I3 PedalDn
7
E200P Installation Manual
4 I4 PedalUp
5 I5 Mode
6 I6 SafeIn
7 I7 MRDY
8 I8 LDP En.
9 COM COM1
1 2 3 4 5 6 7 8 9
1 O1 Y1
2 O2 Y2
3 O3 Y3
4 O4 Y4
5 O5 Y5
6 O6 EH
7 O7 ER
8 O8 -
9 COM COM2
Pin 1 2 3 4 5 6 7 8, 9 Shell
8
E200P Installation Manual
Pin 1 6 7 8 9 4 2 3 5 Shell
Signal CANH CANL +3.3V 485A 485B BOOT TXD RXD GND EARTH
9
E200P Installation Manual
Step 1 When the E200P device is electrified, wait a few seconds into the SINGLE page
(Default page), as shown in Figure 3-1.
SINGLE
X= 100.50 Y = 120.05
XP = 55.00
55.00 YP = 0.00
DX = 20.00 HT = 2.00
Step 2 Press two times to enter the CONST page, as shown in Figure 3-2.
CONST
:Unit of Length
[Teach-in parameter]
Move the cursor to parameter mm/inch or 中文/English, enter the password 1212, and press
to enter the TchIn PARA page, as shown in Figure 3-3.
TchIn PARA
: Set Pos. of X
[Configure parameter]
Move the cursor to parameter mm/inch or 中文/English, enter the password 36987, and press
to enter the CONFIG PARA. page, as shown in Figure 3-3.
11
E200P Installation Manual
CONFIG PARA.
Step 3 Move the cursor to parameter mm/inch or 中文/English, enter the password 14789,
and press to enter the PARAMETER SET page, as shown in Figure 3-5.
PARAMETER SET
1. SYSTEM PARA
2. X AXIS PARA
3. Y AXIS PARA
4. YV SETTING
5. BACKUP/LOAD
:Press‘NUM’Enter
12
E200P Installation Manual
X-Digits: 2 Bit
Y-Digits: 2 Bit
X-Safe: 10.00 mm
Y-Safe: 5.00 mm
Step Delay: 0.00 S
Light En.: 0 0-Dis. 1-En.
Cont. Enable: 0 0-Dis. 1-En.
LDP Enable: 0 0-Dis. 1-En.
:Digits of axis X
[Note] If the parameter OPEN En. on the 2/3 page is set to 1, press key to enter the second
page of the SYS PARA., and set the linear relationship between the Open distance and duration.
13
E200P Installation Manual
X PARA. 1/3 PG
[Note] Repower the device, and the X-axis parameters can be available.
14
E200P Installation Manual
15
E200P Installation Manual
16
E200P Installation Manual
Y PARA. 1/3 PG
17
E200P Installation Manual
3.5 YV Setting
On the SYS PARA. page, move the cursor to parameter 4.YV SETTING (or press the
number key 4), and press to enter the YV MONITOR page, as shown in Figure
3-9.
18
E200P Installation Manual
YVSet
19
E200P Installation Manual
The BACKUP/LOAD page does not make processing to the program parameters,
such as SINGLE parameters, MUTIL-STEP parameters.
BACKUP: store the current parameter settings.
LOAD: recovery the current parameter settings to the last backup.
On the SYS PARA. page, move the cursor to parameter 5.BACKUP/LOAD (or press
the number key 5), and press to enter the BACKUP/LOAD page, as shown in
Figure 3-10.
[Operation Guide]:
Move the cursor to parameter 1.PARA BACKUP, and long press to start
backup operation, until the page tips Backup Done.
Move the cursor to parameter 2.PARA LOAD, and long press to start backup
operation, until the page tips Load Done.
BACKUP/LOAD
1. PARA BACKUP
2. PARA LOAD
:Press‘±’to start
20
E200P Installation Manual
Chapter 4 Diagnose
Step 1 When the E200P device is electrified, wait a few seconds into the SINGLE page
(Default page).
Step 2 Press two times to enter the CONST page.
Step 3 Move the cursor to parameter mm/inch or 中文/English, enter the password 5656, and
press to enter the PARAMETER SET page, as shown in Figure 4-1.
DIAGNOSE
----End
21
E200P Installation Manual
[Operation Guide]:
Switching high level to the corresponding relay, the device will detect the input
signal, and the background color of the corresponding port icon on the page will
change, that this input port is normal.
IN DIAG.
22
E200P Installation Manual
[Operation Guide]:
Move the cursor to any icon of the port, and press to switch the level. If the
background color of the corresponding port icon on the page changes, and the
corresponding relay turns, that this output port is normal.
OUT DIAG.
23
E200P Installation Manual
[Operation Guide]:
Press any key on the operation board, and check the key name feedback on the
page whether is correct.
KEY DIAG.
Enter
24
E200P Installation Manual
[Operation Guide]:
Press to start diagnosing. If the FRAM is normal, the page will tip The result
is: OK.
FRAM DIAG.
Press‘±’to start
25
E200P Installation Manual
[Operation Guide]:
Rotating the Encoder, the corresponding C pulse width will change between 0 and
1, and the value of Vn (n is the port number of the encoder) changes, that the
encoder port is normal.
ENC. DIAG.
Encoder1: 0
Encoder1 C: 0
26
E200P Installation Manual
[Operation Guide]:
LCD diagnose is mainly used for checking the screen whether there is bright or dark
sports.
Press to start diagnosing, the page switch to the monochrome screens, please
check whether there is bright or dark spots.
LCD DIAG.
Press‘±’to start
27
E200P Installation Manual
The RESUME page does not make processing to the program parameters, such
as SINGLE parameters, MUTIL-STEP parameters.
On the DIAGNOSE page, move the cursor to parameter 7.RESTORE. (or press the
number key 7), and press to enter the RESUME page, as shown in Figure 4-8.
[Operation Guide]:
Press to factory setting, until the page tips “恢复完成, 请重启!”and then
restart the device.
RESUME
Press‘±’to start
28
E200P Installation Manual
Chapter 5 Commissioning
Check power supply and ground wire before power on the system.
Enter Diagnose page, check system’s input signal. When there is input signal, the
corresponding input indication is filled; otherwise, input signal is not connected.
Enter Diagnose page, check system’s output signal. When there is output signal,
the corresponding output indication is filled. If machine tool fails to operate normally,
check electrical parts of the machine tool.
5.2 Procedure
5.2.1 Parameter setting
1 When the E200P device is electrified, wait a few seconds into the SINGLE page
(Default page).
2 Press two times to enter the CONST page.
3 Move the cursor to parameter mm/inch or 中文/English, enter the password 14789,
and press to enter the PARAMETER SET page.
4 Move the cursor to parameter 2.X AXIS PARA (or press the number key 2), and press
to enter the first page of the X PARA.
5 Set the following parameter on the X PARA. page:
X-Enable: 1
X FactA: 40
X FactB: 1
X-Encoder Dir.: 1
X-Min: 10.00
X-Max: 500.00 (this value is determined by gauge length)
X-Teach. En: 1
X-Ref. Pos: 10.00
X-Overrun. En.: 1
X-Over. Dis.: 5.00
29
E200P Installation Manual
Press and hold , watch the gauge whether move to the maximum position
slowly, if not, please enter the X PARA. page, and set the parameter
X-MotorDirection to 1.
Press and simultaneity, and watch the gauge whether move to the
minimum position fast.
5.2.3 Counting
Edit multistep program on programming page (setting number of work piece is over 1,
single step is excluded), press , and depress pedal to dry running when X, Y axle
are in position (note Y axle position and pressure), observe whether counting has
increased; if no change occurs, check whether I1 signal wire (Step) is reliably
connected to the system.
5.2.4 Retract
5.2.5 Teaching
When the above procedures are finished, roughly correct actual position of X and Y axle
by teach function. Edit single step program to carry out actual processing, measure
dimension of the processed work piece, then correct scale error by teach function.
30
E200P Installation Manual
Chapter 6 Maintenance
When power is on or system operates normally, do not open cover plate or panel as
it may damage the components.
Do not place system on metal product that may cause power leakage, or on wood,
plastic or vinyl product which has static electricity.
Do not add voltage values excluded in operating manual on any binding post.
Otherwise damage or breakage may be caused.
Control line and communication cable shall not be together with or close to principal
line and power harness. Their distance between each other shall be over 100mm
during installation.
31
E200P Installation Manual
32
E200P Installation Manual
33
E200P Installation Manual
Appendix A Wiring
1
+24V
ENCODER
CN2(INPUT) CN3(OUTPUT)
Encoder
2
CN5
0V
3
PE
E200P
Shield
CN1
R-120Ω
-SV1 -SV2
Shield
L2
L2 FG
FG
L3
L3
+WB +WB
+WB +WB
-SQ -SQ -KM4 -SQ -SQ
-KM4
-M2 -M2
Encoder
Encoder
-E -E
34
E200P Installation Manual
CONST
0: mm
mm/inch 0 0~1 -
1: inch
0: 中文
中文/English 0 0~1 -
1: English
The delay time for the slide
Release Delay 0.50 s releasing the pressure after
bending.
The current software version
Version - - -
number.
TchIn PARA
When the teaching of X-axis is
enabling, the operator assigns to
X-tea. in 10.00 0~9999.999 mm/inch the X-axis of a correct value, to
represent the backgauge current
position.
When the teaching of Y-axis is
enabling, the operator assigns to
Y-tea. in 10.00 0~9999.999 mm/inch the Y-axis of a correct value, to
represent the slider current
position.
CONFIG PARA.
0: Disable, the function of YV
output is normal.
YV5->NCRDY 0 0, 1 - 1: Enable, the function of YV
output is changed to NCRDY
output.
0: Semi.
Jog Mode 0 0, 1 -
1: Jog
SYS PARA.
The number of decimal places to
X-Digits 2 0~3 - display the X-axis position
parameters.
The number of decimal places to
Y-Digits 2 0~3 - display the Y-axis position
parameters.
35
E200P Installation Manual
36
E200P Installation Manual
37
E200P Installation Manual
38
E200P Installation Manual
SINGLE
XP 0.00 0~9999.999 mm/inch Program position of X axle.
YP 0.00 0~9999.999 mm/inch Program position of Y axle.
DX 0.00 0~9999.999 mm/inch Retract distance of X axle.
The interval time from LDP
HT 0.00 0~99.99 s signal to decompression
process.
In case of single step, delay time
DLY 0.00 0~99.99 s
for X-axle retracting.
The number of processing
PP 0 0~9999 -
workpiece in this program.
PP=0: this value is the current
work piece.
CP 0 0~9999 -
PP>0: this value is the remain
work piece.
After bending, the distance of the
OPN 0.00 0~999.999 mm/inch
Y-axis opening.
PROGRAM
The total number of steps in this
ST 1 0~25 -
program.
The number of processing
PP 0 0~99999 -
workpiece in this program.
PP=0: this value is the current
work piece.
CP 0 0~99999 -
PP>0: this value is the remain
work piece.
In case of single step, delay time
DLY 0.00 0~99.99 s
for X-axle retracting.
The interval time from LDP
HT 0.00 0~99.99 s signal to decompression
process.
STEP
XP 0.00 0~9999.999 mm/inch Program position of X-axis.
YP 0.00 0~9999.999 mm/inch Program position of Y-axis.
DX 0.00 0~9999.999 mm/inch Retract distance of X axle.
After bending, the distance of the
OPEN DIST 0.00 0~999.999 mm/inch
Y-axis opening.
Repeat Times 1 1~99 - The repeat times in this step.
39