0% found this document useful (0 votes)
74 views2 pages

Alind Technical Flyer

Uploaded by

StelistuSuper
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views2 pages

Alind Technical Flyer

Uploaded by

StelistuSuper
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Medium Voltage Service Technical Flyer

Retrofit solutions for ALIND/ALSTOM HL make minimum


oil circuit breaker

The foremost advantage of retrofitting


a circuit breaker in switchgear is that
the required specifications are met
with the latest technology at only a
partial cost of replacing the equipment.
This becomes more evident when
the associated costs of civil works,
cabling and downtime are considered.
Retrofitting helps in saving up to 60
percent of the cost of new equipment.
Typically, retrofitting constitutes
replacement of vital equipment having
similar or advanced features, for life
extension, reduced maintenance and
improved functionality. This includes
upgradation and modernization of
basic equipment and allied parts. The
retrofitted switchgear offers far greater
system, reliability, long term safety and
long term availability of spares with
minimal investment and downtime.
ABB is a full system provider for
retrofit solutions, from the proposal
and design, through the manufacturing
and testing, up to the installation and Alind/Alstom HL breaker
commissioning.
Benefits
Reliability
– Significant life time extension
– Lower maintenance requirements
– Long time availability of spare parts
Safety
– Strong fault risk reduction
– Additional embedded safety features
– Improved operator protection

1VYN000001 Rev.00 en - Copyright© 2014 ABB. All rights reserved.


Technology
– Latest generation apparatus
– Designed according to IEC 62271-100 Standard
– Tested and certified products
Project
– Short implementation time for replacement
– Minimum shutdown of the switchboard
– Smooth site activity
Investment
– Limited capital investment
– Minimization of further maintenance costs
– Warranty on the conversion work

Facts
These circuit breakers are widely present in the networks and
ABB can provide the relevant retrofitting solutions across the ABB VD4 vacuum retrofit of Alind/Alstom HL breaker
globe. This equipment has been in service for many decades
and retrofitting could significantly extend the operational life
of the switchgear. The use of well proven VD4 Vacuum circuit
breaker enhances the reliability of the switchgear. The retrofit
circuit breakers can be fitted with Surge Arresters or Potential For more information please contact Service department at:
Transformers on request. Many types of existing circuit
ABB India Limited
breakers can be identified by looking at the rating plates Viz.
PPMV – Retrofit & Services
HL430, HL436 & HL446.
Plot No. 79, Street No. 17,
MIDC Estate,
Technical data
Satpur Nashik,
A full range of retrofit solutions have been developed based
Maharashtra, India – 422007
on ABB vacuum and gas circuit breakers. Fused vacuum
Tel: +91 253-2201200
contactor is also available for replacing Motor Starter Units.
Fax: +91 253-2351260
ABB proposal provides the best fit for purpose apparatus for
Email: ppmvsupport@in.abb.com
each switchgear unit, depending of the complete network, 
equipment conditions and the specific feeder operational www.abb.com
characteristics.

NOTE:
The following basic details are necessary for providing
We reserve the right to make changes in the course of technical
standard retrofit solutions:
development.
– Height, width and depth of the circuit breaker compartment
– GA, cross section and schematic drawing of the existing
panel
– Height, width and depth of the panel
– Control & motor voltage
– Feeder details

You might also like