Suprema BioEntryW
Suprema BioEntryW
                      Installation Guide
                               EN 101.00.BEW V1.30
                               www.supremainc.com
BioEntry W
  Carefully review the information within the user manual before installing/operating the device.
  Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to
  any person(s) or property associated with the device.
        Warning                                                            Caution
        Failure to heed these warnings may lead to serious                 Failure to heed these cautions may lead to minor injury
        injury or even death!                                              or damage the device.
Installation Installation
    Do not install the device near heat sources such as radiators,    Do not install the device in a place subject to direct sun light,
     heat registers, and stoves.                                        humidity, dust or soot.
    Do not install the device near areas of large electromagnetic     Do not leave cables (especially power cables) exposed to
     interference.                                                      the outer environment.
                                                                       Do not install the device near objects with a strong magnetic
                                                                        field such as magnets, computer monitors (especially CRT),
                                                                        TV screens and speakers.
                                                                       Secure I/O, the electrical locking device and access controller
      Usage                                                             must use independent power source.
  What is a fingerprint?
            Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint
            recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from
            the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing
            PIN or cards.
  Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint
  condition or positioning. However pay careful attention to the following instructions to maximize the performance
  of the device.
  Fingerprint Enrollment
                It is recommended to enroll the index or middle finger.
                 The thumb, ring or little finger are generally more difficult to position properly.
           Operational Warnings
                  If a finger is wet or too moist, wipe off the moisture then try the scan again.
                  If a finger is covered with dust or impurities, clean the finger then try the scan again.
                  If a finger is dry, breathe warm air onto the finger then try the scan again.
Components
 Basic Components
Diode (1)
               BioEntry W
                            Wall Mounting bracket (1)      Software CD (1)
Components
 Optional Accessories
Product Description
 Front
                                                                       Pink            Processing
                    RFID Scanner                               Flicker Blue/Sky-Blue
                       Place an RFID card over the                                    Standard Operation
                                                                   Color per 2sec
                        scanner.
                                                                 Flicker Red/Pink
                                                                                       Device Locked
                                                                  Color per 2sec
                                                                 Flicker Blue/Red
                                                                                       Discharged Internal Battery
                                                                  Color per 2sec
                                                                                       Unable to Acquire an IP
                    Fingerprint Sensor                          Flicker Blue/Yellow
                                                                                       Address from the DHCP
                       Place a finger on the surface of the       Color per 2sec
                                                                                       Server.
                        sensor.
                                                               Flicker Red Color per   Unit Malfunction. Contact Your
                                                                        2sec           Suprema Dealer/Distributor.
                                                               Flicker Yellow Color
                                                                                       Waiting for an Input
                                                                     per 2sec
                                                               Flicker Yellow Color    Requesting IP Address from
                                                                     per 1sec          the DHCP Server.
Product Description
                         Cables
                             Wiegand Input/Output Cables
                             Power Cables
                             RS485 Cables
                             Ethernet Connector
                             Input Cables
                             Relay Cables
                         LED
                             Network Status LED
Dimensions
44 mm 50 mm 40 mm
Cable Specifications
2 SWIN0 PURPLE
7 POWER IN RED
15 WIEGAND D1 WHITE
16 WIEGAND D0 GREEN
17 NC PINK
Installation
  1. Fix the wall mounting bracket on a wall by            3. Fix the device to the wall mounting bracket using the
     using wall mounting screws.                              star-shaped screws.
                                                                                      Star-shaped
                                                                                         screw
                                                   Wall
                                                  Mount
                                                  Screws
System Configurations
 Standard
Door Sensor
BioEntry W
LAN
                                                      PC        USB Fingerprint
                                                                   Scanner
System Configurations
Door Sensor
                                                                      Secure I/O
          BioEntry W
LAN
                                                                                   USB Fingerprint
                                                                 PC
                                                                                      Scanner
System Configurations
 Network
RS485 RS485
                                                                   Secure I/O
       FaceStation
                             BioEntry W    BioEntry W
LAN
                                                                                 PC Client
       FaceStation            Secure I/O   BioEntry W              Exit Button
                     RS485
                                                                                 PC Client
                             Door Zone 2 (Anti-passback)
Connections
 Power Connection
                                                                          DC Power
                                                                       DC Power Supply
                                                                                                             UPS
                                                                           Supply                          (Optional)
Connections
Ethernet Hub
Connections
Connections
                                                                                                Power IN (Red)
                                                                                                Power GND (Black)
              GND -                                                                             Signal GND (Black/White Stripe)
              TRX+                                                                              TRX+ (Blue/White Stripe)
               TRX-                                                                             TRX- (Yellow/White Stripe)
        RS232-485                                                                                         BioEntry W
         Converter
                                                              Power IN (Red)
                                                              Power GND (Black)
                                                              Signal GND (Black/White Stripe)
                                                              TRX+ (Blue/White Stripe)
                                                              TRX- (Yellow/White Stripe)
BioEntry W
       Notes
          −     Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter,
                refer to the converter’s manual.
          −     Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be
                necessary to lower the baudrates.
          −     The GND signal may be omitted if and only if the GND potential difference is less than ±5V.
Connections
BioEntry W BioEntry W
            Notes
                −    For bus termination, only the devices at both ends of the bus should be terminated.
                −    Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os.
Connections
BioEntry W
Connections
BioEntry W
Connections
RTE Switch
                                            Presence
                                            Detector
BioEntry W
Connections
BioEntry W
                         Request TO
                            Exit
Connections
BioEntry W
Switch #2
Connections
 Wiegand Input
 Wiegand Output
Controller BioEntry W
  In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the
  device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the
  back panel of the device. Please refer to the figures as below.
        2.   Press and hold the network reset switch until the device
             turns off. (Then, the device will restart.)
Electrical Specifications
Pull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistors.
VOH (V) - 5 -
                           Voltage            -       -     24 VDC
       Relay
                           Current            -     0.5 A    1.0 A
Product Specifications
                                         BioEntry W
                                                       50 x 172 x 44 mm
                                         (W x H x D)
        General     Dimensions
                                        Wall Bracket
                                                       40 x 157 mm (screw joint included)
                                          (W x H)
Troubleshooting
  Please contact your local dealer/distributor for support or contact Suprema at support@supremainc.com.
  Please submit the following information and we will coordinate support with your local dealer/distributor.
         Device model
         F/W version of the device
         H/W version of the device
         Detailed information regarding the issue
         Error messages / screenshots, if possible
         Contact information (Company, Name, Telephone, Email)
FCC Rules
     Caution
      Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the
      user’s authority to operate the equipment.
     Warning
      This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
      device may not cause harmful interface, and (2) this device must accept any interface received, including
      interference that may cause undesired operation.
     Information to User
      This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of
      the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
      residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed
      and used in accordance with the instructions, may cause harmful interference to radio communications. However,
      there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful
      interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
      encouraged to try to correct the interference by one or more the following measures: