General Information
GENERAL INFORMATION
 MARATHON ELECTRIC                                                                         WEBSITE AND E-COMMERCE
 Since 1913, Marathon Electric’s name has been recognized                                  Information can be accessed instantly, any time of the
 for engineering excellence, custom-designed products                                      day on ME-business. Marathon customers can sign-up
 and an extensive product line of industrial quality motors.                               for ME-business by contacting their sales representative.
 Available in all popular enclosures from 1/12 HP through
 3000 HP and in a variety of mounting configurations,                                      ME-business can be accessed through: www.
 Marathon Electric’s unique designs provide more ways                                      marathonelectric.com.
 in which to add accessories, such as blowers, brakes and
 encoders, to our motors than anyone else in the motor                                          •   Stock Availability
 business. Our state-of-the-art lab facilities are equipped                                     •   Order Status
 and staffed with the finest resources available to ensure                                      •   Shipping Information
 successful utilization of our products. Finally, as the                                        •   Invoice Information
 preferred supplier of motors to most of the top drive                                          •   Product features and performance data
 manufacturers in North America, we have what it takes to
 be a leader in understanding the interaction of drives as
 they are applied with AC induction motors.
Marathon Electric Nameplate Information                                                                       - HOW TO READ THE NAMEPLATE
The nameplate is the key to selecting the proper replacement motor.
                                                                                                               CSA Verification Mark - Complies with
                                                                                                               CSA’s Energy Efficiency Verification
                                                                                                               Service and their Standard C390 - C390
                                                                                                               is the Canadian efficiency equivalent of
                  2            1                            3                     4                            EPAct.
                   5                                                 6                                          Underwriters Laboratories, Inc.
                       7                  8             9       10          11                      12
                        13                    14                     15   16               17
                                                                                                                UL Recognized Component Mark
                               18                               19                    20                        UL file #
                                                                     32                    33
                  21                 22                                                                        CE (Conformité Européene) Marking
                                                                                                               This mark signifies the motor complies
                  23                 24
                         25                        26                                                          with the European Low Voltage
                              27              28                                                               Directive.
                         29                                                                                    CSA Mark - Certified by the Canadian
                                    30                                           31                            Standards Association
                                                                                                               CSA file #
                                                                                                               CC# - Compliance Certification Number
                                                                                                               as per assigned by the Department
                                                                                                               of Energy. Motors meeting EPAct
                                                                                                               efficiencies or higher will have this
      Motor Specifications (Example)                                             Agency Symbols                number.
 1.   MODEL - The ID number 				                                            19. WT/LBS - Motor weight in pounds 			
 2.   DATE CODE - The month and year manufactured		                         20. WT/KG - Motor weight in kilograms
 3.   MTG. - Mounting 					                                                 21. HZ - Input frequency of the power supply, usually 50 or 60 HZ 		
 4.   FRAME - The size & mounting 					 22. VOLTS - Voltage rating of the motor at the operating frequency		
 5.   PART NO. - Customer part number				 23. HP - Rated horsepower the motor will produce
 6.   SER. - Serial number				                                              24. KW - Rated output in watts 				
 7.   TYPE - Electrical type 						 25. F.L. AMPS - The rated load current expressed in amps at nameplated
 8.   DES. - Code by NEMA or IEC				                                        		 horsepower with nameplate voltage and frequency
 9.   PH - Electrical phase usually 1 or 3 				 26. S.F. - Percentage of the rated horsepower the motor can safely operate at:
10.   INS CL - Insulation Class						                                       		 Example: 1.15 SF (115% of rated HP) 		
11.   DUTY - Time rating under load					 27. PF / COS - Power Factor / Cosine is the ratio of actual power to the
12.   MAX AMB - The allowable surrounding air temperature                   		 apparent power
13.   ENCL - Enclosure (i.e. TEFC)                                          28. RPM - Full load speed at rated frequency
14.   RISE - The temperature rise over ambient expressed in degrees 		 29. NOM EFF - Average Efficiency
		    Celsius when the motor operates at nameplated HP or KW                30. SHAFT END BEARING - Manufacturer drive end bearing number
15.   IP - Inherent Protection of the enclosure to solids and liquids as 		 31. 	OPP. END BEARING - Manufacturer opposite drive end bearing
		    defined by IEC 34-5 			                                                     number
16.   IC - Inherent Cooling                                                 32. SHAFT END BRG - Drive end bearing size
17.   CODE - NEMA locked-rotor KVA					 33. OPP - Opposite drive end bearing size
18.   MTH/YR MFG. - Month and year motor was manufactured
              SB300 – Prices and Specifications are subject to change without notice.                                                                     5
                      General Information
GENERAL INFORMATION
                      HOW TO READ A MODEL NUMBER:                                             5. Electrical Type
                      Each Marathon Electric motor carries a model number that                   Single Phase:
                      can be used to define some of the motor’s physical and                  				A = Permanent split capacitor
                      electrical characteristics.                                             				 B = Capacitor start, capacitor run
                                                                                              				 C = Capacitor start, induction run
                      Example (For Fractional): 1PC48C17D2000AP                               				N = Split phase start, capacitor run
                                                                                              				 S = Split phase
                      This is a breakdown of the model on the nameplate:
                                                                                                 Three Phase:
                            1     P    C      48     C      17    D   2000     A     P        				 T = Three phase
                            1     2    3       4     5      6     7    10     11    12        				H = Inverter Duty/IEEE841 Inverter Duty
                                                                                              				 V = Medium Voltage
                      This is a breakdown of the model in the catalog:                        		DC Power:
                                                                                              				 E = Permanent Magnet DC
                            48    C   17      D     2000
                             4    5   6       7      10                                       6. RPM or Speed at 60 Hz (Fractional Only)
                                                                                              			 34 = 2-Pole, 3600 rpm
                      Example (For Integral): 2QA215TBDRA7076ALL
                                                                                              			 17 = 4-Pole, 1800 rpm
                      This is a breakdown of the model on the nameplate:                      			 11 = 6-Pole, 1200 rpm
                                                                                              				 8 = 8-Pole, 900 rpm
                            2     Q    A     215T    B      D     R    A     7076   AL   L
                            1     2    3       4     5      7     8    9      10    11   12   7. Enclosure
                                                                                              				 D = Dripproof
                      This is a breakdown of the model in the catalog:                        				 E = Explosion proof, non-ventilated
                                                                                              				 F = Totally enclosed, fan cooled
                           215T   B    D      R      A     7076
                             4    5    7      8      9      10                                				G = Explosion proof, fan cooled
                                                                                              				 O = Open
                      1.     Date Code - Year of Manufacture                                  				 P = Partial
                             		           (Not shown in catalog listings.)                    				 S = Semi-enclosed
                                                                                              				 T = Totally enclosed, non-ventilated
                      2.     Thermal Protection (Not shown in catalog listings.)              			 V = Washdown, non-ventilated
                                                    UL Recognized            UL Recognized
                                                                                              				W = Washdown, fan cooled
                                                    Motor Protector              Motor
                                                     Combination              Construction    8.   Frame Construction
                                                                                                   Integral                                Fractional   (where applicable)
                           Automatic Reset          Automatic Reset        Automatic Reset
                                                                                                   L   = Aluminum (Full Frame)             B   =   Rolled Steel - Sourced
                                 Q                       Yes                    Yes
                                                                                                   Y   = Aluminum (Full Frame)             D   =   Stainless Steel - Sourced
                                 S                       No                     No
                                 U                       No                     Yes           		Z = Aluminum (High Mount Down Frame)       U   =   Frameless - Sourced
                                W                         #                     Yes                H   = Aluminum - Sourced
                            Manual Reset             Manual Reset           Manual Reset      		R = Rolled Steel (Full Frame)
                                 P                       Yes                    Yes           		W = Rolled Steel (Full Frame)
                                 Z                       No                     Yes           		X = Rolled Steel (High Mount Down Frame)
                                 X                       No                     No            		B = Rolled Steel - Sourced
                               None                     None                   None           		S = Cast Iron (Full Frame)
                                 V                       No                     Yes
                                                                                              		N = Cast Iron (Full Frame)
                                                                                              		P = Cast Iron (High Mount Down Frame)
                            # Motor protector combination is U.L. recognized only
                                                                                              		C = Cast Iron - Sourced
                            if motor is used in direct drive fan duty application, and        		D = Stainless Steel
                            is under locked rotor condition, or is running under
                            no-load condition.                                                9.   Style Letter (A, B, C, etc. indicate redesign)
                      3.    Date Code - Month of Manufacturer (Not shown in                   10. Sequence Number
                            catalog listings.)
                                                                                              11.		Minor Modification Letter(s)
                      4.    NEMA Frame Size - (Integral motors - T and U designate            			 Fractional - 1 letter; Integral - 2 letters
                            standard shaft, TS and US designate short shaft)
                                                                                              12.		Manufacturing Code - A code for the factory where the
                                                                                                   motor was manufactured.
                      6                                                SB300 – Prices and Specifications are subject to change without notice.
General Information
                                                                                                                                   GENERAL INFORMATION
HOW TO READ A MODEL NUMBER: Continued
Example (“harmonized” motor design):                             E.   Stack Length
                                                                      A - 5/8”   F -   1-1/4”     L -   1-7/8”   S-   3.0”
     A     B     C     D      E     F      G     H      I             B - 3/4”   G-    1-3/8”     M-    2.0”     T-   3-1/4”
     5    KH     3     6      K     G     142    –      X             C - 7/8”   H-    1-1/2”     N-    2-1/4”   U-   3-1/2”
                                                                      D - 1.0”   J -   1-5/8”     P-    2-1/2”   W-   4.0”
                                                                      E - 1-1/8” K -   1-3/4”     R-    2-3/4”   Q-   Spec.
A.   Rotating Device
                                                                 F.   Endshield Construction
B.   Type of Winding                                                   G & N - Aluminum
     KH - Split Phase                                                  K - Steel
     KC - Capacitor Start, Induction Run                               C - Cap/Can
     K - Polyphase
     KCP - Permanent Split Capacitor                             G. Sequence Number
     KCR - Capacitor Start, Capacitor Run
                                                                 H.   Current Revision (blank if original)
C.   Lamination Size
     3 - 48 frame, 4 - 56 frame                                  I.   Type   of Overload
                                                                      X -    UL Auto running & locked rotor
D. Length of Frame                                                     Y -   UL Manual running & locked rotor
		      48 frame            56 frame                                   S -   UL Auto locked rotor
   2       5.17                5.73                                    T -   Non-UL Auto running & locked rotor
   3       5.42                6.63                                   U -    Non-UL Manual running & locked rotor
   4       None                None                                    V -   Thermostat
   5       5.80                7.11                                   W -    UL Motor Parts
   6       6.23                None
   7       6.63                7.63
   8       7.23                8.44
   9       Spec.	              Spec.
ORDERING INFORMATION                                             Non-stock Product Cancellation policy:
When ordering, please include the model number, catalog          Cancellation charges for non-stock orders received and
number, description of the motor, quantity, shipping and         entered will be determined based on the percentage of
billing instructions. For pricing of non-stock motors, or if     completion in the engineering and manufacturing process,
you need assistance in selecting the proper motor, please        accounting for all costs plus a reasonable profit. Marathon
contact your nearest Marathon Electric sales representative      Electric’s determination of the cancellation charges shall
or local Marathon Electric Distributor. All prices and data      be conclusive.
are subject to change without notice.
                                                                 DISCOUNTS AND MULTIPLIERS
CANCELLATIONS AND RETURNS                                        Except as noted, all prices in this catalog are list prices.
                                                                 200 and 575 volt 3 phase ratings utilize the same list price
Stock Product                                                    as 230/460 volt. NEMA short shaft (TS) utilize the same list
Stock product can be returned for credit as defined herein.      price as standard shaft (T). Contact Marathon Electric for
Equipment must be in original packaging, unused in “as           special bearing systems, including all requirements for
shipped” condition and is limited to products currently          sleeve or roller bearing. For your discount and multiplier,
maintained in stock inventory. The quantity returned             contact your local Marathon Electric sales representative or
cannot exceed Marathon Electric’s normal stock quantity          local Marathon Electric Distributor.
level. All motors returned must have date codes no older
than 18 months from date of manufacture. The minimum             MODIFICATION/ACCESSORIES
restocking charge is 15% of the original net purchase price.     See the Modification/Accessories Sections for more
Modified and build to order motors cannot be returned for        information on modifications to create special motor
credit. Return freight charges are the responsibility of the     variations.
customer returning the motor for credit. No returns will be
accepted without prior authorization.
           SB300 – Prices and Specifications are subject to change without notice.                                             7
                      General Information
GENERAL INFORMATION
                      STOCK, NON-STOCK AND BUILD UP MODELS                          STORAGE PROCEDURES
                      Standard motors listed in this catalog, as indicated with a   In the event that long-term storage of motors is required,
                      check mark (�) next to the catalog number, are normally       Marathon Electric recommends the following precautions
                      in stock. There is no minimum order quantity or minimum       and procedures. This information is also contained in
                      billing charge associated with stock motors, unless stated    “Installation, Operation and Maintenance Instructions”
                      otherwise in your quotation or agreement with Marathon        (SB181).
                      Electric.
                                                                                      A.     Keep motors clean
                      Production of non-stock catalog models and all build-up       		       1. Store indoors
                      models is subject to minimum order quantities or setup        		       2. 	Keep covered to eliminate airborne dust
                      charges listed below.                                                       and dirt.
                                                                                    		       3. 	Cover openings for ventilation, conduit
                      48-140 Frame = 25 piece minimum                                             connections, etc., to prevent entry of rodents,
                      180-210 Frames = 5 piece minimum or $200 set-up/                            snakes, birds and insects.
                      model
                      250-320 Frames = 5 piece minimum or $300 set-up/                B.     Keep motors dry
                      model                                                         		       1. Store in a dry area indoors
                                                                                    		       2. 	Temperature swings should be minimal to
                      Build-up motors must be thoroughly described at time of                     prevent condensation.
                      order, and/or associated with a formal quotation issued       		       3. 	Space heaters are recommended to prevent
                      by Marathon Electric. Inclusion of product features for                     condensation.
                      similar motors documented in this catalog should not be       		       4. 	Treat unpainted flanges, shafts and fittings
                      assumed.                                                                    with a rust inhibitor.
                                                                                    		       5. 	Check insulation resistance before putting
                      SERVICE                                                                     motor into service.
                      For service on any Marathon Electric motor, contact your
                      nearest Marathon Electric Authorized Service Station.           C.     Keep bearings lubricated
                      For a complete listing of all domestic and foreign service    		       1. 	Once per month, rotate shaft several turns to
                      stations, refer to www.marathonelectric.com.                                distribute grease in bearings.
                                                                                    		       2. 	If unit has been stored more than one
                      OPERATION AND MAINTENANCE                                                   year, add grease before start-up (refer to
                      For information on operation and maintenance, please                        lubrication procedure).
                      consult the manual or card shipped with your new
                      motor. Additional copies of “Installation, Operation          DIMENSION DRAWINGS
                      & Maintenance Instructions” (brochure SB181) are              See Marathon Electric’s website: www.marathonelectric.
                      available upon request or through our website, www.           com or request certified drawings through your Marathon
                      marathonelectric.com.                                         Electric Sales Engineer, Representative or local Marathon
                                                                                    Electric Distributor.
                      8                                        SB300 – Prices and Specifications are subject to change without notice.
General Information
                                                                                                                                                 GENERAL INFORMATION
WARRANTY
Marathon Electric warrants Fractional and Integral motors to be free from defects in materials and workmanship and to
conform to Marathon’s written specifications.
		                                                                                                 Warranty               Warranty
			                                                                                              Period from             Period from
			                                                                                                 Date of                Date of
Motor Type		                                                                                     Installation*          Manufacture*
   Standard Warranty for any product not shown below                                                    12                      18
   Medium Voltage		                                                                                     12                      18
   EPAct compliant (aluminum, steel & cast iron frame)                                                  24                      30
   Blue Chip Severe Duty Explosion Proof                                                                24                      30
   Blue Max®, Black Max®, & microMax™ Inverter Duty                                                     36                      42
   All NEMA Premium® incl. ODP, Blue Chip, Severe Duty, Explosion Proof, etc.                           36                      42
   U-Frame Automotive Duty		                                                                            60                      66
   Blue Chip IEEE-841		                                                                                 60                      66
* Warranty period shown is in months, and is valid for whichever period expires first.
Note: Brake discs are considered a normal maintenance item and are not covered under warranty.
For more information, on Marathon Electric’s warranty policy, refer to the “Terms and Conditions of Sale” (MPN411) in the back
of this catalog.
SUBMITTAL DATA
Mechanical and electrical submittal data is available on         SUBMITTAL CHARGE SCHEDULE
many stock catalog motors through our website                      TYPE             ELEMENTS                                     NET/EA
                                                                                 Nameplate data
www.marathonelectric.com by following the three steps            		              Motor characteristics
listed on the next page. All other submittal data is available   BASIC (.PDF     Performance data                               No-Charge
                                                                   format)       Outline drawing
upon request when accompanied by a purchase order for
                                                                 		              External connection diagram
the specified motor, subject to the following additional         		              Add for .dxf or .dwg format                         $25
charges                                                                          All “BASIC” elements, tailored to
                                                                  BASIC-PLUS     specific order.
                                                                                                                                     $75
                                                                  (.pdf format)
                                                                 		              “Cut sheets” of installed accessories
                                                                 		              Add for .dxf or .dwg format                         $25
                                                                 		              Speed/Torque curve                                  $50
                                                                 		              Torque capability curve                             $50
                                                                 ADDITIONAL      Commercial (end of line) test results (not
                                                                                                                                     $50
                                                                     ITEMS       available for West Plains motors)*
                                                                 (.pdf formats)  Certificate of conformance                         $100
                                                                 		 Thermal damage curve (48-326T frame)                       $500 + cost of
                                                                 			                                                          additional motor
                                                                 		 Thermal damage curve (364T-6805 frame)                     $1500 +cost of
                                                                 			                                                          additional motor
                                                                 * Does not imply retesting
          SB300 – Prices and Specifications are subject to change without notice.                                                          9
                      General Information
GENERAL INFORMATION
                       1. From our homepage, click on the Motors link.
                       From the Motors page, enter in the Marathon
                       Catalog number or Model number.
                       Then click on Model number in results window.
                       (Note: If you already have a Marathon Electric motor and
                       are looking for the performance data, make sure the model
                       number off the nameplate is what you use for your search.
                       Ex. 056H17T5301).
                       2. The Motor Model Details page will appear. You will be
                       able to print dimensional drawings and connection diagrams
                       in PDF format for the motors. Under the Technical Data
                       section, click on the link, Certification Data Sheet.
                       3. Your results will look similar to the example shown to
                       the right for Marathon’s 1/2 HP, Black Max® motor, model
                       # 056H17T5301. It’s that easy!
                      10                                     SB300 – Prices and Specifications are subject to change without notice.