PRODUCT INFORMATION PACKET
Model No: 170122.60
Catalog No: 170122.60
WATTSAVER® General Purpose Motor, 7.50 & 5 HP, 3 Ph, 60 & 50 Hz, 208-230/460 & 190/380 V,
1200 & 1000 RPM, 254T Frame, TEFC
Regal and Leeson are trademarks of Regal Rexnord Corporation or one of its affiliated companies.
©2023 Regal Rexnord Corporation, All Rights Reserved. MC017097E
1 of 6
Product Information Packet: Model No: 170122.60, Catalog No:170122.60 WATTSAVER® General Purpose Motor, 7.50 & 5 HP, 3 Ph, 60 & 50 Hz, 208-
230/460 & 190/380 V, 1200 & 1000 RPM, 254T Frame, TEFC
Nameplate Specifications
Phase 3 Output HP 7.50 & 5 Hp
Output KW 5.6 & 3.7 kW Voltage 208-230/460 & 190/380 V
Speed 1185 & 990 rpm Service Factor 1.15 & 1.15
Frame 254T Enclosure Totally Enclosed Fan Cooled
Thermal Protection No Protection Efficiency 91.7 & 91.7 %
Ambient Temperature 40 °C Frequency 60 & 50 Hz
Current 23-22.2/11.1 & 19/9.5 A Power Factor 70
Duty Continuous Insulation Class F
Design Code B KVA Code H
Drive End Bearing Size 6309 Opp Drive End Bearing Size 6308
UL Recognized CSA Y
CE Y IP Code 43
Number of Speeds 1
Technical Specifications
Electrical Type Squirrel Cage Inverter Rated Starting Method Wye Start Delta Run Or Inverter
Poles 6 Rotation Reversible
Mounting Rigid Base Motor Orientation Horizontal
Drive End Bearing Ball Opp Drive End Bearing Ball
Frame Material Cast Iron Shaft Type T
Overall Length 23.19 in Shaft Diameter 1.625 in
Shaft Extension 4 in Assembly/Box Mounting F1 ONLY
Connection Drawing 004172.01 Outline Drawing 16953860-254T
This is an uncontrolled document once printed or downloaded and is subject to change without notice. Date Created:06/21/2023
2 of 6
9/27/2008 2:42:05 PM
3 of 6
6/28/2007 3:22:15 PM -
4 of 6
Uncontrolled Copy
5 of 6
Uncontrolled Copy
Data Sheet
Date: 1/23/2018 170122.60
Data @ 460 v
Motor Load Data
Load 0% 25% 50% 75% 100% 115% 125% LR
Current (Amps) 5.3 6.0 7.5 9.0 11.1 11.8 12.8 67.0
Torque (ft-lb) 0.00 8.2 16.5 24.8 33.2 38.2 41.6 65.0
RPM 1200 1197 1194 1190 1185 1,184 1180 0
Efficiency (%) 82.5 89.5 91.7 91.7 91.7 91.7
P.F. (%) 6.0 34.0 53.5 65.0 70.0 73.5 74.5 0.0
Motor Speed Data
LR Pull-Up BD Rated Idle
Speed (RPM) 0 400 1135 1185 1200 Information Block
Current (Amps) 67.0 64.0 42.0 11.1 5.3 HP 7.5
Torque (ft-lb) 65.0 55.0 113 33.2 0.00 Sync. RPM 1200
Frame 254
Efficiency (%) P.F. (%) Current (Amps) Enclosure TEFC
Construction TFC
100.0 14.0
Voltage 208-230/460#190/380 V
Frequency 60 Hz
90.0 12.0 Design B
LR Code letter H
E Service Factor 1.15
F 80.0 10.0
Temp Rise @ FL 31 °C
F A Duty CONT
M
Ambient 40 °C
70.0 8.0 P
P Elevation 1,000 feet
S
F Rotor/Shaft wk² 2.47 Lb-Ft²
Ref Wdg T12906018 NONE
60.0 6.0
Sound Pressure @ 1M 52 dBA
VFD Rating CONSTANT 10:1
50.0 4.0
Outline Dwg 16953860
Conn. Diag 004172.01
40.0 2.0 Additional Specifications:
0
0
30.0 0.0 EQUIV CKT (OHMS / PHASE)
0% 20% 40% 60% 80% 100% 120% 140% R1 R2 X1 X2 Xm
LOAD 0.0000 0.0000 0.0000 0.0000 0.0000
Speed -Torque Curve
Torque Amps
120.0 80.0
70.0
100.0
60.0
80.0
50.0
T
A
O
M
R 60.0 40.0 P
Q
S
U
E
30.0
40.0
20.0
20.0
10.0
0.0 0.0
0 200 400 600 800 1000 1200 1400
RPM
6 of 6