0% found this document useful (0 votes)
67 views31 pages

5 Port Solenoid Valve: Body Ported

This document provides information about 5 port solenoid valves including specifications, features, applications, and variations. It describes the valve components, functions, and mounting options. Diagrams and tables further illustrate valve configurations and component details.

Uploaded by

happy.360vina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views31 pages

5 Port Solenoid Valve: Body Ported

This document provides information about 5 port solenoid valves including specifications, features, applications, and variations. It describes the valve components, functions, and mounting options. Diagrams and tables further illustrate valve configurations and component details.

Uploaded by

happy.360vina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 31

5 Port Solenoid Valve

Plug Lead Type RoHS

New Body Ported V Valve width: 7.4 mm


V Possible to drive cylinders: Up to ø32 (300 mm/s) ∗

Flow-rate characteristics∗ ∗ For details, refer to page 6.

∗ For single/double solenoid V Power consumption: 0.35 W


C [dm3/(s·bar)]: 0.6 V Weight: 39 g∗
∗ Single solenoid, built-in silencer type
New
• Added 3-position closed center.
• Direct EXH outlet with built-in
With One-touch fittings silencer (Option)
Size can be changed. (For details, refer to page 27.) 7.5 mm pitch

Single Unit Port size Manifold With One-touch fittings


Metric: ø2, ø3.2, ø4 Size can be changed. (For details, refer to page 27.)
Inch: ø1/8", ø5/32"
Port size
Metric: ø2, ø3.2, ø4
Inch: ø1/8", ø5/32"

Width:
7.4 mm
New
Added 3-position
closed center.
Built-in silencer (Option)
New (For details, refer to page 20.)
Pitch: 7.5 mm

Base Mounted Possible to drive cylinders: Up to ø 25 (300 mm/s)


∗ For details, refer to page 6.

Flow-rate characteristics
Power consumption: 0.35 W
New Added 3-position closed center.
C [dm3/(s·bar)]: 0.39
Single Unit Manifold
7.5 mm pitch 8.5 mm pitch

Serial transmission/EX510
Width 7.4 mm

7.5 mm 8.5 mm
With barb fittings With One-touch fittings
(ø2, ø3.2, ø4) (ø2, ø3.2, ø4, ø1/8", ø5/32")

Series S0700
CAT.ES11-109A
5 Port Solenoid Valve Plug Lead Type Series S0700

4-Position Dual 3-Port Valve Adopted Direct Manual.


· Two 3-port valves in A side B side Symbol Possible to switch the main valve reliably by direct
one body. 4(A) 2(B) manual override even when pressure is below the
operating pressure range during maintenance.
· Independently operating N.C. N.C.
3-port valve at each 5(R1) 3(R2)
side of A and B.
1(P)
4(A) 2(B)
· Number of stations
occupied for 3-port
valve halved. N.O. N.O.
5(R1) 3(R2)

· Available as 4-position 1(P)


5-port valve. 4(A) 2(B)
Main valve
N.C. N.O.
5(R1) 3(R2)

1(P)

Applications
Transportation of packaged work piece
S0700

S0700

Air cylinder

Plug-in Type Series Variations For details, refer to the WEB catalog or
the Best Pneumatics No. 1.

Slim Compact Plug-in Manifold


Plug-in Manifold Stacking Base
Bar Base Many Combinations Available to Fit Your Needs
· Serial transmission
Footprint: Reduced by 45%∗ EX180/EX260/EX250
Height: Reduced by 20 mm∗ EX600/EX500/EX510
∗ Compared with plug-in manifold stacking base
· D-sub connector
· Flat ribbon cable
· PC wiring system compatible
flat ribbon cable
· Terminal block box
· Lead wire
· Circular connector

1
5 Port Solenoid Valve Plug Lead Type Series S0700

Variations/Options
Body Ported Base Mounted Single Unit
Manifold pitch: 7.5 mm Manifold pitch: 8.5 mm Manifold pitch: 7.5 mm Body Ported Base Mounted

Page 10 Page 15 Page 15 Page 7 Page 12

Base model

SS0752-mmC SS0755-mCmC SS0755-mVmC S07m6-5m-m-m S07m5-5m-M5


M5 V V
Rc1/8 V V

1(P), ø2 V
3(R) ø4 V
Piping specifications

ø1/8" V
ø5/32" V
Port size

M3 V
M5 V V
ø2 V V V Note 1) V
4(A),
ø3.2 V V Note 1)
2(B)
ø4 V V V Note 1) V
ø1/8" V V V
ø5/32" V V V

C Kit: Connector
Type of wiring C Kit: Connector S Kit: Serial transmission C Kit: Connector Connector kit Connector kit
(EX510)

Direct EXH outlet with V


— — — —
built-in silencer Page 20

V V V
Blanking plate assembly — —
Page 20 Page 20 Page 20

V Note 2) V Note 2) V Note 2) V Note 2) V Note 2)


External pilot
Page 20 Page 20 Page 20 Page 20 Page 20

V V
Individual SUP spacer — — —
Page 20 Page 20

V V
Individual EXH spacer — — —
Page 21 Page 21

V
Port plug — — — —
Page 21

V V V V
Blanking plug —
Page 21 Page 21 Page 21 Page 21

Silencer V V V
— —
(For manifold EXH port) Page 21 Page 21 Page 21

Double check block V V V V V


(Separated) Page 22 Page 22 Page 22 Page 22 Page 22

Note 1) For barb fittings


Note 2) Not compatible with dual 3-port valves.

2
5 Port Solenoid Valve Plug Lead Type Series S0700

INDEX
Valve Specifications................................................................................. Page 4

Manifold/Single Unit Specifications......................................................... Page 5

Manifold Flow-rate Characteristics.......................................................... Page 5

Cylinder Speed Chart .............................................................................. Page 6

Symbol...................................................................................................... Page 6

Body Ported Bar Base

Single Unit................................................................................................ Page 7

Manifold Individual Wiring C Kit . .......................................................... Page 10

Base Mounted Bar Base

Single Unit................................................................................................ Page 12

Manifold Individual Wiring C Kit . .......................................................... Page 15

Serial Transmission S Kit ..................................................................... Page 18

Options . ................................................................................................... Page 20

Construction............................................................................................. Page 23

Replacement Parts . ................................................................................ Page 25

Specific Product Precautions ................................................................. Page 26

3
Series S0700
Valve Specifications
Valve Specifications

Model
Flow-rate characteristics Note 2)
Note 3)
Type of Response
Type Model 1R4/2 (PRA/B) 4/2R5/3 (A/BRR1/R2) Weight
actuation time
[g]
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv [msec]
2-position

Single S0716 0.62 0.44 0.18 0.60 0.41 0.17 22 or less 39

Double S0726 0.62 0.44 0.18 0.60 0.41 0.17 10 or less 47


Single Unit
4-pos. 3-pos.

3-position
Page 7 S0736 0.54 0.37 0.15 0.50 0.38 0.14 45 or less 47
closed center
Body Ported

Dual 3-port A
S07 B 6 0.58 0.39 0.16 0.67 0.37 0.18 25 or less 49
valve C
2-position

Single S0712 0.51 0.40 0.15 0.64 0.33 0.15 22 or less 34

Double S0722 0.51 0.40 0.15 0.64 0.33 0.15 10 or less 42


Manifold
4-pos. 3-pos.

Bar Base 3-position


S0732 0.54 0.37 0.10 0.46 0.38 0.08 45 or less 42
Page 10 closed center
Dual 3-port A
S07 B 2 0.57 0.39 0.15 0.55 0.37 0.15 25 or less 44
valve C
2-position

Single S0715 0.39 0.39 0.11 0.37 0.39 0.10 12 or less 28


Single Unit
Base Mounted

Page 12 Double S0725 0.39 0.39 0.11 0.37 0.39 0.10 10 or less 36

Manifold
4-pos. 3-pos.

3-position
Bar Base S0735 0.29 0.29 0.07 0.26 0.21 0.06 28 or less 38
closed center
Page 15 Dual 3-port A
S07 B 5 0.34 0.34 0.09 0.33 0.33 0.08 12 or less 36
valve C

Note 1) Values for cylinder port fitting port size C4. The flow rate of a body ported single valve is the SUP and EXH port C4 value.
Note 2) Based on JIS B 8375-1993 (Supply pressure: 0.5 MPa, with indicator light and surge voltage suppressor, clean air. This will change depending on
pressure and air quality.) The value when ON for the double type.
Note 3) The weight of a single unit of the valve includes a built-in EXH port silencer.
Note 4) The flow rate of the body ported product with an external pilot decreases by 10%.
Note 5) The flow rate of the body ported product with a built-in silencer decreases by 30%.

Specifications
Valve construction Rubber seal
Fluid Air
Maximum operating pressure 0.7 MPa
Valve specifications

Minimum operating pressure 0.2 MPa


Ambient and fluid temperature −10 to 50°C Note 1)
Maximum operating cycle 5 Hz
Pilot valve exhaust method Individual exhaust
Pilot valve manual override Push type
Lubrication Not required
Impact/Vibration resistance Note 2) 30/100 m/s2
Enclosure IP40
Noise reduction (Built-in silencer) 20 dB(A) Note 3)
Coil rated voltage 24 VDC
specifications
Electrical

Allowable voltage fluctuation ±10% of rated voltage


Coil insulation type Class B or equivalent
Power consumption (Current) 24 VDC DC 0.35 W (15 mA)
Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-
energized states every once for each condition.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000 Hz.
Test was performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature.
Note 3) The value may vary depending on the pneumatic circuit or pressure.
4A
Series S0700

Manifold/Single Unit Specifications

Piping specifications Note 1)


Note 3) Note 3)
5-station Addition
Model Port size Type of connection Applicable
weight per station
stations
1(P), 3(R) 4(A), 2(B) [g] [g]
Manifold pitch: 7.5 mm
Page 10
Body Ported

C2 (ø2)
C4 (ø4) Max.
Rc1/8 C Kit: Connector 76 10
N1 (ø1/8") 20 stations
N3 (ø5/32")

SS0752-C
Manifold pitch: 8.5 mm
Page 15 C Kit: Connector
Max.
115 20
M5 thread 20 stations
C2 (ø2)
C3 (ø3.2)
Rc1/8
C4 (ø4)
N1 (ø1/8") Note 2)
N3 (ø5/32") S Kit: Serial transmission Max. 115 20
Base Mounted

(EX510) 16 stations
SS0755 -mCmC
Manifold pitch: 7.5 mm
Page 15
M3 (M3 thread)
V2 (ø2 Barb fitting) Max.
M5 thread C Kit: Connector 75 10
V3 (ø3.2 Barb fitting) 20 stations
V4 (ø5 Barb fitting)

SS0755 -mVmC

Page 7
Body Ported

C2 (ø2) C2 (ø2)
C4 (ø4) C4 (ø4)
Connector kit — — —
N1 (ø1/8") N1 (ø1/8")
N3 (ø5/32") N3 (ø5/32")
Single Unit

S07m6-5m -m-m

Page 12
Base Mounted

M5 thread M5 thread Connector kit — 14 Note 4)

S07m5-5m -M5
Note 1) Maximum stations in the case of mixed single and double wiring (special wiring specifications)
Note 2) Differs depending on the serial unit type. For details, refer to the WEB catalog or the Best Pneumatics No. 1.
Note 3) Weight excluding valve. For valve weight, refer to page 4.
Note 4) Weight of sub-plate only. For valve weight, refer to page 4.

Manifold Flow-rate Characteristics

Flow-rate characteristics
Port size
1R4/2 (PRA/B) 4/2R5/3 (A/BREA/EB)
Model
1, 5, 3 4, 2
C [dm3/(s·bar)] Cv C [dm3/(s·bar)] Cv
(P, EA, EB) (A, B)
SS0752-mmC 1/8 C4 2.6 0.71 2.7 0.75
SS0755-mCmC 1/8 C4 2.1 0.58 1.9 0.53
SS0755-mVmC M5 thread V4 0.86 0.24 0.86 0.24
∗ When 5-station single solenoids are operated simultaneously.

5
Valve Specifications Series S0700

Cylinder Speed Chart

Applicable cylinder Applicable cylinder


Type
speed ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø50

Body Ported
100 mm/s or less
Base Mounted

Body Ported
300 mm/s or less
Base Mounted

Body Ported
500 mm/s or less
Base Mounted

[Common conditions]
• Pressure: 0.5 MPa
• Piping length: 1 m
• Load ratio: 50%
• Stroke: 200 mm
∗ Use as a guide for selection.
Please confirm the actual conditions with SMC Model Selection Software.

Symbol

Model Type of actuation Symbol


(A)(B)
4 2
S0712
S0716 2-position single
S0715 (R1)5 1 3(R2)
(P)

(A)(B)
4 2
S0722
S0726 2-position double
S0725 (R1)5 1 3(R2)
(P)

(A)4 2(B)
S0732
S0736 3-position closed center
S0735
(R1)5 1 3(R2)
(P)

4(A) 2(B)

S07A2 4-position dual 3-port


S07A6 N.C. + N.C. 5(R1) 3(R2)
S07A5 (Exhaust center)

1(P)

4(A) 2(B)

S07B2 4-position dual 3-port


S07B6 N.O. + N.O. 5(R1) 3(R2)
S07B5 (Pressure center)
1(P)

4(A) 2(B)

S07C2
4-position dual 3-port
S07C6 N.C. + N.O. 5(R1) 3(R2)
S07C5
1(P)

6
Plug Lead Type

Body Ported
Single Unit
Series S0700 RoHS

How to Order Valves

S07 1 6 S 5 G C4

Type of actuation P, E port/A, B port size


Symbol Specifications Symbol Port size
1 2-position single C2 ø2 One-touch fitting
2 2-position double C4 ø4 One-touch fitting
3 3-position closed center N1 ø1/8" One-touch fitting
4-position dual 3-port (N.C. + N.C.) N3 ø5/32" One-touch fitting
A (Exhaust center) Note) F
 or external pilots, the P, E, and X ports
4-position dual 3-port (N.O. + N.O.) are size M3. (Refer to page 9.)
B (Pressure center)
C 4-position dual 3-port (N.C. + N.O.)

Electrical entry
Symbol Specifications Configuration
Body Ported
Note) It cannot be mounted on a manifold.

G Grommet
Function
Symbol Type

Nil EXH port: With One-touch fitting


M-type plug connector, with 300 mm
M lead wire (With light/surge voltage
suppressor)

S EXH outlet: With built-in silencer Note 1)

M-type plug connector, without lead


MO wire (With light/surge voltage
suppressor)

R External pilot Note 2)

Note 1) Refer to page 20.


Note 2) Not compatible with dual 3-port valves.

Voltage
Symbol Type
5 24 VDC
6 12 VDC

7
S0700
Plug Lead Type
Body Ported Single Unit Series

Dimensions
2-Position Single
Grommet: S0716-mG-m 8
2 x ø3.2

5.3
2 x C2, C4, N1, N3 <4(A), 2(B) port>
C2: ø2 One-touch fitting
C4: ø4 One-touch fitting
N1: ø1/8" One-touch fitting
N3: ø5/32" One-touch fitting
Manual override 56.4

(Lead wire length)


(Lead wire length)

10.5

≈ 300
7.4
58.5
≈ 300

41.8
39.7
≈ 9.2

31.5
28.5

22.9
22.8

20.4
22
10.5

3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> 8 8


≈ 8.7

C2: ø2 One-touch fitting 16.7 With plug connector/light,


C4: ø4 One-touch fitting built-in silencer
N1: ø1/8" One-touch fitting
S0716S-mM(O)-m
N3: ø5/32" One-touch fitting

2-Position Double/4-Position Dual 3-Port


2
Grommet: S07 AB 6-mG-m
C
8

2 x ø3.2
5.3

2 x C2, C4, N1, N3 <4(A), 2(B) port>


C2: ø2 One-touch fitting
C4: ø4 One-touch fitting
N1: ø1/8" One-touch fitting
N3: ø5/32" One-touch fitting
Manual override 79.3
(Lead wire length)
(Lead wire length)

≈ 300

10.5
7.4
≈ 300

83.6
Manual override 41.8
39.7
≈ 9.2

31.5
28.5

22.9
22.8

20.4
22
10.5

3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> 8 8


≈ 8.7

C2: ø2 One-touch fitting 16.7 With plug connector/light,


C4: ø4 One-touch fitting built-in silencer
N1: ø1/8" One-touch fitting 2
N3: ø5/32" One-touch fitting S07 AB 6S-mM(O)-m
C
8
Series S0700

Dimensions
3-Position Closed Center
Grommet: S0736-mG-m 8

2 x ø3.2

5.3
2 x C2, C4, N1, N3 <4(A), 2(B) port>
C2: ø2 One-touch fitting
C4: ø4 One-touch fitting
N1: ø1/8" One-touch fitting
Manual override N3: ø5/32" One-touch fitting
86.7

10.5

(Lead wire length)


(Lead wire length)

7.4
Manual override

≈ 300
≈ 300

91
41.8
39.7
≈ 9.2

31.5
28.5

22.9
22.8

20.4
22
10.5

8 8
≈ 8.7

3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> 16.7 With plug connector/light,
C2: ø2 One-touch fitting
built-in silencer
C4: ø4 One-touch fitting
N1: ø1/8" One-touch fitting S0736S-mM(O)-m
N3: ø5/32" One-touch fitting

External Pilot
2-Position Single 2-Position Double/3-Position Closed Center
Grommet (G): S0716R-mG-m-m Grommet (G): S07 23 6R-mG-m-m
(Lead wire length)
(Lead wire length)

≈ 300
≈ 300

56.4 79.3 <86.7>


39.7 39.7
≈ 9.2
≈ 9.2

28.5
28.5

22.8
22.8

20.4
20.4

22
22

25 16.7 25 16.7
5.3
≈ 6.9

5.3
≈ 6.9

< >: 3-position closed center

21 21
8.2 8.2 8.2 8.2

M3 x 0.5 M3 x 0.5 M3 x 0.5 M3 x 0.5


External pilot port <1(P), 5(EA), 3(EB) port> External pilot port <1(P), 5(EA), 3(EB) port>
∗ Other dimensions are the same as the internal pilot.
9
Plug Lead Type

Manifold Bar Base


Body Ported
Individual Wiring: C Kit
Series S0700 RoHS

How to Order Manifold

SS07 5 2 08 C
5 port Thread type
1(P), 3/5(R) port
Body Ported Nil Rc
00N NPT
00T NPTF
Stations
00F G
Symbol Stations
02 2 stations
03 3 stations
Option
Symbol Type

20 20 stations Nil None


Note) Max. 20 stations R External pilot

Individual wiring

How to Order Valves How to Order Manifold Assembly


Specify the part numbers for valves and options

S07 1 2 5 G C4
together beneath the manifold base part number.
<Example>
Connector kit
………… 1 set–Manifold base part no.
SS0752-08C
∗ S0712-5G-C4 …… 2 sets–Valve part no. (Stations 1 to 2)
Body Ported ∗ S0722-5G-C4 …… 2 sets–Valve part no. (Stations 3 to 4)
Voltage
Manifold Bar Base ∗ S0732-5G-C4 …… 2 sets–Valve part no. (Stations 5 to 6)
Symbol Type
Note) The valve cannot be ∗ S07A2-5G-C4…… 2 sets–Valve part no. (Stations 7 to 8)
used as a stand- 5 24 VDC
alone unit. 6 12 VDC Prefix the Write sequentially from
asterisk to the the 1st station on the D
part numbers side. When part
Function Electrical entry of the solenoid numbers written
Symbol Type Symbol Specifications valve etc. collectively are
Nil Standard G Grommet complicated, specify on
the manifold
R External pilot Note) M-type plug connector, with 300 mm lead wire
M (With light/surge voltage suppressor)
specification sheet.
Note) Not compatible with dual
3-port valves. M-type plug connector, without lead wire
MO (With light/surge voltage suppressor)

ide
Us
Type of actuation Cylinder port size
Symbol Specifications Symbol Port size
1 2-position single C2 ø2 One-touch fitting
ns
tio

2 C4
a

2-position double ø4 One-touch fitting


St

3 3-position closed center N1 ø1/8" One-touch fitting


3

N3 ø5/32" One-touch fitting ide


2

4-position dual 3-port (N.C. + N.C.) Ds


1

A (Exhaust center)
4-position dual 3-port (N.O. + N.O.)
B (Pressure center)
C 4-position dual 3-port (N.C. + N.O.)

10
Series S0700

Dimensions
SS0752-mC
L2

47 ≈ 300
Manual override L1 5
(Lead wire length) (n-1) x 7.5 12.7
41.3
7.5
10.7
2 x ø4.2 Mounting hole
8.2
2 x Rc1/8
56.4 (Single solenoid)

56.4 (Single solenoid)


79.3 (Double solenoid dual 3-port)

79.3 (Double solenoid dual 3-port)


3(R) port
86.7 (Closed center)

86.7 (Closed center)

38
29.3

21.8
22
14.2

2n x C2, C4, N1, N3 <4(A), 2(B) port>

4.5
11.5
4.5
2 x Rc1/8 C2: ø2 One-touch fitting
1(P) port C4: ø4 One-touch fitting
N1: ø1/8" One-touch fitting
Grommet N3: ø5/32" One-touch fitting
M3 x 0.5 External pilot port
(External pilot type)

49.8 ≈ 300 D side Stations 1 2 3 4 5 6 7 8 n U side

40.5 (Lead wire length)


83.6 (Double solenoid dual 3-port)
58.5 (Single solenoid)

91 (Closed center)

18.5

Indicator light

With plug connector/light

Dimensions Formula L1 = 7.5n + 7.9, L2 = 7.5n + 17.9 n: Station (Maximum 20 stations)


L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 15.4 22.9 30.4 37.9 45.4 52.9 60.4 67.9 75.4 82.9 90.4 97.9 105.4 112.9 120.4 127.9 135.4 142.9 150.4 157.9
L2 25.4 32.9 40.4 47.9 55.4 62.9 70.4 77.9 85.4 92.9 100.4 107.9 115.4 122.9 130.4 137.9 145.4 152.9 160.4 167.9

11
Plug Lead Type

Base Mounted
Single Unit
Series S0700 RoHS

How to Order Valves

S07 1 5 5 G M5
With/Without sub-plate
Symbol Type
Nil Without sub-plate
M5 With sub-plate

Electrical entry
Symbol Specifications Configuration

Type of actuation
Symbol Specifications
1 2-position single
2 2-position double G Grommet
3 3-position closed center
4-position dual 3-port (N.C. + N.C.)
A [Exhaust center]
4-position dual 3-port (N.O. + N.O.)
B [Pressure center]
C 4-position dual 3-port (N.C. + N.O.)
Note) For symbol, refer to page 6. M-type plug connector, with lead wire
M (With light/surge voltage suppressor)

Base Mounted

Function
Symbol Type
Nil Standard M-type plug connector, without lead wire
MO (With light/surge voltage suppressor)
R External pilot Note)
Note) Not compatible with
dual 3-port valves.

Voltage
Symbol Type
5 24 VDC
6 12 VDC

12
Series S0700

Dimensions
2-Position Single
Grommet: S0715(R)-mG-M5 21.2
M5 x 0.8 1(P) port
11.4

5.2
7.7
M5 x 0.8 3(R) port

Manual override

3.3
7.4

19

(Lead wire length)


2 x ø3.5
(Lead wire length)

21.4 3.2
Mounting hole
28

≈ 300
≈ 300

50.3
48.2
Indicator light

43
40
34.5

34.5
31.2

31.2
7

11.5

M5 x 0.8 2(B) port


5.7

10 With plug connector/light


8.4
M3 x 0.5 External pilot port M5 x 0.8 4(A) port 18.6
S0715(R)-mM(O)-M5
(External pilot type only)

2-Position Double/4-Position Dual 3-Port


2
Grommet: S07 AB 5(R)-mG-M5 21.2
C M5 x 0.8 1(P) port
11.4
7.7
5.2

M5 x 0.8 3(R) port

Manual override Manual override


7.4

19

(Lead wire length)


(Lead wire length)

2 x ø3.5 21.4 3.2


3.3

Mounting hole
≈ 300

28
≈ 300

Indicator light
68.5 72.8
43
40
34.5

34.5
31.2

31.2
7

11.5

10 M5 x 0.8 2(B) port With plug connector/light


5.7

8.4 2
M3 x 0.5 External pilot port M5 x 0.8 4(A) port
18.6 19.5
S07 AB 5(R)-M(O)-M5
(External pilot type only) C

13
S0700
Plug Lead Type
Base Mounted Single Unit Series

Dimensions
3-Position Closed Center
Grommet: S0735(R)-mG-M5
M5 x 0.8
21.2
1(P) port
11.4

5.2
7.7
M5 x 0.8
3(R) port 3
1

Manual override Manual override


7.4

19
3.3
2 x ø3.5 21.4 3.2
Mounting hole 28

(Lead wire length)


(Lead wire length)

≈ 300
≈ 300

Indicator light
76.5
81
39.7
43
40

34.5
34.5
31.2

31.2
7

X
4 2 4 2
11.5
5.7

10
8.4
With plug connector/light
M3 x 0.5 External pilot port 18.6 27.4
S0735(R)-mM(O)-M5
(External pilot type only)
M5 x 0.8
4(A) port
M5 x 0.8
2(B) port

14
Plug Lead Type

Manifold Bar Base


Base Mounted
Individual Wiring: C Kit
Series S0700 RoHS

How to Order Manifold

SS0755 08 C4 C
Base Mounted
Option
Symbol Type
Stations
Nil None
Symbol Stations
R Note) External pilot
02 2 stations
Note) For details, refer to page 20.

∗ For manifold optional parts,


20 20 stations refer to pages 20 to 22.

Cylinder port size


Symbol Port size Manifold pitch Connector individual wiring
M5 M5 thread
C2 With ø2 One-touch fitting
C3 With ø3.2 One-touch fitting Metric P, R port thread type
C4 With ø4 One-touch fitting Manifold pitch
8.5 Symbol
CM Mixed sizes and with port plug Note) 8.5 7.5
N1 With ø1/8" One-touch fitting Nil Rc M5
N3 With ø5/32" One-touch fitting Inch F G
NM Mixed sizes and with port plug Note) N NPT
M3 M3 thread T NPTF
V2 ø2 Barb fitting
V3 ø3.2 Barb fitting Metric 7.5
V4 ø4 Barb fitting
VM Mixed sizes and with port plug Note)
Note) Specify “Mixed sizes and with port plug” on the manifold
specification sheet.

How to Order Valves How to Order Manifold Assembly


Specify the part numbers for valves and options

S07 1 5 5 G
together beneath the manifold base part number.
<Example>
Type of actuation Connector kit
Electrical entry
SS0755-07C4C… 1 set–Manifold base part no.
Symbol Specifications Symbol Specifications ∗ S0715-5G …… 3 sets–Valve part no. (Stations 1 to 3)
1 2-position single
∗ S0725-5G …… 2 sets–Valve part no. (Stations 4 to 5)
2 2-position double G Grommet
∗ S07A5-5G …… 2 sets–Valve part no. (Stations 6 to 7)
3 3-position closed center Plug connector, with lead wire
4-position dual 3-port (N.C. + N.C.)
M (With light/surge voltage suppressor) Prefix the Write sequentially from
A [Exhaust center] asterisk to the the 1st station on the D
Plug connector, without lead wire part numbers side. When part
4-position dual 3-port (N.O. + N.O.)
MO (With light/surge voltage suppressor)
B [Pressure center]
of the solenoid numbers written
valve etc. collectively are
C 4-position dual 3-port (N.C. + N.O.) Voltage complicated, specify on
Note) For symbol, refer to page 6. Symbol Type the manifold
specification sheet.
5 24 VDC
6 12 VDC

Base Mounted Function Us


ide
Manifold Symbol Type
Nil Standard
ns

R External pilot Note)


io
at
St

Note) Not compatible with dual


3-port valves.
3

ide
2

Ds
1

15
S0700
Plug Lead Type
Base Mounted Manifold Bar Base Series

Dimensions
M5
SS0755-m CNm
m L2
48.5 ≈ 300 (4.5) L1 4.5
43 (Lead wire length) (n-1) x 8.5 12.7
7.7 M3 x 0.5 External pilot port 8.5
(External pilot type)
2 x 1/8 Manual override
3(R) port

(Double solenoid dual 3-port)

(Double solenoid dual 3-port)


 = Thread type

(Single solenoid)

(Single solenoid)
2 x ø4.5

76.5 (Closed center)

76.5 (Closed center)


Mounting hole

R
48.2

48.2

3
X
36.5

68.5

68.5

(32)

24.1
P

P
1
15.6

16.4
2 x 1/8
1(P) port
(With One-touch fitting)

 = Thread type

10.2
≈9

39.7
D side Stations 1 2 3 4 5 6 7 8 n U side
Grommet

51.4 ≈ 300
43 (Lead wire length)
(Double solenoid dual 3-port)
(Single solenoid)

2 2
B B

20
14
4 4
81 (Closed center)
50.3

A A

14.6

5
2n x C2, C3, C4, M5, N1, N3 <4(A), 2(B) port>
72.8

C2: ø2 One-touch fitting


C3: ø3.2 One-touch fitting
C4: ø4 One-touch fitting
M5: M5 thread
N1: ø1/8" One-touch fitting
N3: ø5/32" One-touch fitting
39.7 Indicator light

With plug connector/light

Dimensions Formula L1 = 8.5n + 8.9, L2 = 8.5n + 17.9 n: Station (Maximum 20 stations)


L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 25.9 34.4 42.9 51.4 59.9 68.4 76.9 85.4 93.9 102.4 110.9 119.4 127.9 136.4 144.9 153.4 161.9 170.4 178.9
L2 34.9 43.4 51.9 60.4 68.9 77.4 85.9 94.4 102.9 111.4 119.9 128.4 136.9 145.4 153.9 162.4 170.9 179.4 187.9

16
Series S0700

Dimensions
SS0755-m M3
Vm L2
45 ≈ 300 (4.5) L1 4.5
39.5 (Lead wire length) (n-1) x 7.5 12.7
2 x M5 x 0.8 5.2 M3 x 0.5 External pilot port 7.5
5(R1) port (External pilot type)
Manual override
2 x M5 x 0.8

(Double solenoid dual 3-port)

(Double solenoid dual 3-port)


(Single solenoid)

(Single solenoid)
1(P) port
(With barb fittings)

2 x ø4.5

76.5 (Closed center)

76.5 (Closed center)


48.2 Mounting hole

48.2

R1
5
X
≈5

68.5

68.5

(31)
34
28.7

1
P
6.8

P
1

22.8
17.2

R2

R2
3

3
4.1

16.3
2 x M5 x 0.8
3(R2) port
7.3
36.2
D side Stations 1 2 3 4 5 6 7 8 n U side
Grommet

48 ≈ 300
39.5 (Lead wire length)
(Double solenoid dual 3-port)
(Single solenoid)

2 2

16.5
B B

11
4 4
81 (Closed center)
50.3

A A

14.4

3.5
2n x V2, V3, V4, M3 <4(A), 2(B) port>
72.8

V2: ø2 Barb fitting


V3: ø3.2 Barb fitting
V4: ø4 Barb fitting
M3: M3 thread

36.2 Indicator light

With plug connector/light

Dimensions Formula L1 = 7.5n + 8.9, L2 = 7.5n + 17.9 n: Station (Maximum 20 stations)


L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 23.9 31.4 38.9 46.4 53.9 61.4 68.9 76.4 83.9 91.4 98.9 106.4 113.9 121.4 128.9 136.4 143.9 151.4 158.9
L2 32.9 40.4 47.9 55.4 62.9 70.4 77.9 85.4 92.9 100.4 107.9 115.4 122.9 130.4 137.9 145.4 152.9 160.4 167.9

17
Plug Lead Type

Base Mounted Manifold Bar Base


Serial Transmission: S Kit EX510 Gateway Type
Serial Transmission System

Series S0700 RoHS

How to Order Manifold

SS0755 SA 08 C4
Option
S Kit Symbol Type
EX510 serial wiring Nil None
Note) For SI Unit part number, refer to the WEB catalog Special wiring specifications
or the Best Pneumatics No. 1. K Note 2)
(Except double wiring)
R Note 3) External pilot
SI Unit output polarity Note 1) When multiple options are specified, indicate
Nil Positive common them alphabetically. Example) -KR
N Negative common Note 2) Indicate the wiring specifications for mixed
single and double wirings.
Stations Note 3) For details, refer to page 20.
∗F
 or manifold optional parts, refer to pages 20 to 22.
Symbol Stations
02 2 stations

P, R port thread type


16 16 stations
Manifold pitch
Note) The maximum number of stations is determined by the total number of solenoids. Symbol
For mixed single and double wirings, enter “-K” to the order code options. 8.5
Cylinder port size Nil Rc
Max. number of Symbol Port size F G
Standard Max. number of
station
stations for special
solenoids M5 M5 thread N NPT
wiring specifications T NPTF
C2 With ø2 One-touch fitting
1 to 8 stations 16 stations 16 C3 With ø3.2 One-touch fitting Metric
C4 With ø4 One-touch fitting
Type of actuation Single Double, Dual 3-port CM Mixed sizes and with port plug Note)
Number of solenoids 1 2 N1 With ø1/8" One-touch fitting
N3 With ø5/32" One-touch fitting Inch
For details of the EX510 Gateway Type Serial Transmission System, NM Mixed sizes and with port plug Note)
refer to the WEB catalog or the Best Pneumatics No. 1, and the Note) Specify “Mixed sizes and with port plug”
Operation Manual. Please download the Operation Manual via our on the manifold specification sheet.
website, http://www.smcworld.com

How to Order Valves How to Order Manifold Assembly


Specify the part numbers for valves and options

S07 1 5 5 MO
together beneath the manifold base part number.
<Example>
Serial transmission kit
SS0755-SA08C4…… 1 set–Manifold base part no.
Type of actuation ∗ S0715-5MO ……… 3 sets–Valve part no. (Stations 1 to 3)
Symbol Specifications ∗ S0725-5MO ……… 3 sets–Valve part no. (Stations 4 to 6)
Electrical entry ∗ S07A5-5MO……… 2 sets–Valve part no. (Stations 7 to 8)
1 2-position single
M-type plug connector, without lead wire
2 2-position double
(With light/surge voltage suppressor) Prefix the Write sequentially from the
3 3-position closed center asterisk to the 1st station on the D side.
4-position dual 3-port (N.C. + N.C.) part numbers When part numbers written
A [Exhaust center] Voltage: 24 VDC of the solenoid collectively are complicated,
4-position dual 3-port (N.O. + N.O.) valve etc. specify on the manifold
B [Pressure center] specification sheet. The
connector assembly lead
C 4-position dual 3-port (N.C. + N.O.) Function wire length used for EX510
Note) For symbol, refer to page 6. Symbol Type manifold varies depending
Nil Standard on the number of stations.
R External pilot Note) Therefore, solenoid valves
(including a blanking plate)
Note) Not compatible with dual
Base Mounted Us and connector assembly
3-port valves. ide
are assembled when
Manifold 6
shipped as a standard
Sta specification. Specify the
7

14

tio 15 0

ns
1

8
9 mounting solenoid valve
3 2 Ds when ordering.
1 ide

18
Series S0700

Dimensions
M5
SS0755-SAm CNm
m

48.5 ≈ 300
43 (Lead wire length)

SI UNIT
EX510-S001

(Double solenoid dual 3-port)


(Single solenoid)
COM
PWR

76.5 (Closed center)


48.2

68.5

39.7

Grommet

51.4 ≈ 300 L2
43 (Lead wire length) (4.5) L1 4.5
19.8 (n-1) x 8.5
7.7 13.7 8.5 8.5 12.7

M3 x 0.5 External pilot port


(External pilot type)
2 x 1/8
Manual override
3(R) port
(Double solenoid dual 3-port)
(Single solenoid)

 = Thread type
2 x ø4.5
81 (Closed center)

Mounting hole
50.3

R
3
X
36.5

72.8

32

24.1
1
P

P
1
15.6
≈9

2 x 1/8
1(P) port
 = Thread type
Indicator light
10.2 D side Stations 1 2 3 4 5 6 7 8 n U side
39.7

With plug connector/light

2 2
B B
20
14

4 4
A A
5

14.6
2n x C2, C3, C4, M5, N1, N3 <4(A), 2(B) port>
C2: ø2 One-touch fitting
C3: ø3.2 One-touch fitting
C4: ø4 One-touch fitting
M5: M5 thread
N1: ø1/8" One-touch fitting
N3: ø5/32" One-touch fitting

Dimensions n: Station (Maximum 16 stations)


L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 68.4 68.4 68.4 68.4 68.4 68.4 76.9 85.4 93.9 102.4 110.9 119.4 127.9 136.4 144.9
L2 77.4 77.4 77.4 77.4 77.4 77.4 85.9 94.4 102.9 111.4 119.9 128.4 136.9 145.4 153.9
Note) The L dimension of 2 to 7 stations is the same. Valves are numbered from the D side according up to the number of stations.
19
Series S0700
Options
Body
Ported Direct EXH outlet with built-in silencer [S]

Since a silencer is built into the exhaust port of the valve, it has a high silencing
effect. (Noise reduction: 20 dB(A))
• How to Order Valves (Example)
S0716 S -5G-C4

Built-in silencer
Exhaust outlet
Note) A large quantity of drainage generated in the air source results in exhaust
of air together with drainage.
• For maintenance, refer to page 27.

Body Base
Ported Mounted Blanking plate assembly

SS0700-10A-2/SS0700-10A-5
It is used by attaching on the manifold block for
being prepared for removing a valve for
40.5

maintenance reasons or planning to mount a

40
2
spare valve etc. B

4
A

Applicable manifold Part no. Weight 7.4


7.4
Body ported SS0752 SS0700-10A-2 28 g
Base mounted SS0755 SS0700-10A-5 21 g Body Ported (SS0752) Base Mounted (SS0755)

Body Base
Ported Mounted External pilot [-R]

This can be used when the air pressure is lower than the minimum operating External pilot port
pressure (0.2 MPa) of the solenoid valves or used for vacuum specification. (M3 x 0.5)
Add “-R” to the part numbers of manifolds and valves to indicate the external
pilot specification.
An M3 port will be installed on the top side of the manifold’s SUP/EXH block.
• How to Order Valves (Example)
S0712 R -5G-C4

External pilot Note 1) The dual 3-port valve is not available.


Note 2) When the internal pilot type and external pilot type of
• How to Order Manifold (Example)
valves are mixed up on the manifold, order the manifold
∗ Indicate “-R” for an option. suitable for the specification of the external pilot valve.
SS0752-08C-R Note 3) Valves with the external pilot have a pilot EXH with
individual exhaust specification and EXH can be
External pilot pressurized. However, the pressure supplied from EXH
should be 0.4 MPa or lower.

Base
Mounted Individual SUP spacer

SS0700-P-5-M5 M5 x 0.8
Port size
58.5

P
50

M5 M5 thread P
30

2
B

4
A
Mounted on the manifold block to make an independent supply port when each
solenoid valve uses different operating pressure. 8.3

Weight: 7 g
∗ Compatible with 8.5 mm pitch manifold only.
∗ Cannot be mounted on the body ported manifold (SS0752).
20
Series S0700

Base
Mounted Individual EXH spacer
M5 x 0.8
SS0700-R-5-M5

58.5
Port size

50
R
R

M5 M5 thread

30
2
B

4
Mounted on the manifold block to make an independent exhaust port when the A

exhaust from one valve affects valves on other stations in the air circuit. 8.3
Weight: 7 g
∗ Compatible with 8.5 mm pitch manifold only.
∗ Cannot be mounted on the body ported manifold (SS0752).

Base
Mounted Port plug 11.6

VVQ0000-CP

ø8
The plug is used to block the cylinder port when using a 5-port valve as a 3-port
valve. O-ring
∗ When ordering a plug incorporated with a manifold, indicate “CM” for the port
size in the manifold part number as well as the station number, mounting
positions of cylinder port A/B, on the manifold specification sheet. Port plug

Body Base
Ported Mounted Blanking plug (For One-touch fittings)

KJP-02
L
A
Dimensions [mm]
Applicable Weight
KQ2P-23 fitting size ød
Model A L D [g]
04 2 KJP-02 8.2 17 3 0.1
3.2 KQ2P-23 16 31.5 5 1
øD

4 KQ2P-04 16 32 6 1

Body Base Silencer


Ported Mounted (For manifold EXH port)
Silencer is installed in the EXH port.

AN110-01 AN10-01
(BC sintered body) (Resin)
34
23
ø11
ø13

21
Options Series S0700

Body Base <Check Valve Working Principle>


Ported Mounted Double check block (Separated)

VQ1000-FPG-mm Cylinder side pressure


(P2)
It is used on the outlet side piping to keep the cylinder in the intermediate position for long
periods of time. Combining the double check block with a built-in pilot type double check valve
and a 2-position single/double solenoid valve will permit this block to be used for preventing
the dropping at the cylinder stroke end when the SUP residual pressure is released.
Specifications
Max. operating pressure 0.8 MPa SUP side pressure (P1)
Min. operating pressure 0.15 MPa
Ambient and fluid temperature –5 to 50°C
To
Flow-rate characteristics: C 0.60 dm3/(s·bar) Note) Based on JIS B 8375-1981 cyl
ind
Max. operating frequency 180 c.p.m (Supply pressure: 0.5 MPa) er
po
rt
Dimensions
(5)

18
Single Unit

29
Manifold
10.5
21.5

2n x C4
2n x C4 C4: ø4 One-touch fitting assembly
C4: ø4 One-touch fitting assembly
L3
L2
≈ 4.5

3
Mounting hole for M3 L1

≈ 4.5
Mounting hole for M2.5 15.5 P=11
(3.5)
(30)

5.5
46.5

67
38

67
33
(14)

32.2
8

29.5 Residual pressure 11 Residual pressure


1.7

release manual release manual


38 (17.5) override

1.7
override
(43) 2.5 (22.5) 0.5
D side Stations 1 2 3 n U side DIN rail
2n x C3, C4, M5 2n x C3, C4, M5
C3: ø3.2 One-touch fitting assembly clamping screw
C3: ø3.2 One-touch fitting assembly
C4: ø4 One-touch fitting assembly C4: ø4 One-touch fitting assembly
M5: M5 thread M5: M5 thread

2.5
10.5

Dimensions Formula L1 = 11n + 20 n: Station (Maximum 20 stations)


21.5

n 1 2 3 4 5 6 7 8 9 10
L
45.5
7.5

L1 31 42 53 64 75 86 97 108 119 130


29
18
(5)

L2 50 62.5 75 87.5 100 112.5 125 125 137.5 150


L3 60.5 73 85.5 98 110.5 123 135.5 135.5 148 160.5
n 11 12 13 14 15 16 17 18 19 20
L
L1 141 152 163 174 185 196 207 218 229 240
L2 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250
L3 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5
How to Order
<Example>
Single unit, double check block 2-position
5(R1) 5(R1)
VQ1000 FPG C4 M5 F 1(P) 1(P)
3(R2) 3(R2)
Option
IN side port size OUT side port size Nil None
C4 ø4 One-touch fitting
M5 M5 thread D DIN rail mounting (For manifold)
C3 ø3.2 One-touch fitting F With bracket
C4 ø4 One-touch fitting N With name plate
Note) When multiple symbols are specified,
indicate them alphabetically.
Manifold (DIN rail mounting) Example) -DN
Caution
VVQ1000 FPG 06 • Air leakage from the pipe between the valve and cylinder or from the fittings
When ordering a double will prevent the cylinder from stopping for long periods of time. Check for the 2(B) 4(A)
check block, order the Stations leakage using neutral household detergent, such as dish washing soap.
Also, check the cylinder’s tube gasket, piston seal and rod seal for air leakage.
Bracket Assembly
DIN rail mounting [-D]. 01 1 station Part no. Tightening torque
• Since One-touch fittings allow slight air leakage, screw piping (with M5 thread) is

recommended when stopping the cylinder in the middle for long periods of time. VQ1000-
16 16 stations • M5 fitting assembly is attached, not incorporated into the double check block. 0.22 to 0.25 N·m
<Example> FPG-FB
After screwing in the M5 fittings, mount the assembly on the double check
VVQ1000-FPG-06…6-station manifold Note) This torque is used to
block. {Tightening torque: 0.8 to 1.2 N·m}
Double mount the bracket on the
∗ VQ1000-FPG-C4M5-D: 6 sets • If the exhaust of the double check block is restricted too much, the cylinder
check block double check block.
may not operate properly and may not stop intermediately.
22
Series S0700
Construction
Body
Ported
Construction
2-Position S0716
urew q (A)4 2(B)
Single

(R1)5 1 3(R2)
(P)

t y i

2-Position S0726 (A)4 2(B)


urew q
Double

(R1)5 1 3(R2)
(P)

t y i

3-Position S0736
urew q (A)4 2(B)
Closed Center

(R1)5 1 3(R2)
(P)

t y i

4-Position S07A6
urew q 4(A) 2(B)
Dual 3-Port Valve

5(R1) 3(R2)

1(P)
N.C. + N.C.

S07B6
4(A) 2(B)

t y i
5(R1) 3(R2)

Component Parts 1(P)


No. Description Material N.O. + N.O.
1 Body Zinc die-casted
2 Spool Aluminum S07C6
4(A) 2(B)
3 Piston Resin
4 Manual override Resin
5 Adapter plate Resin 5(R1) 3(R2)
6 Interface gasket HNBR
7 Pilot valve assembly Refer to page 25.
1(P)
8 PR plate Resin Note)
N.C. + N.O.
Note) The external pilot is made of aluminum.
23
Construction Series S0700
Base
Mounted
Construction
2-Position S0715 (A)4 2(B)
Single
u rewq

(R1)5 1 3(R2)
(P)

5 4 1 2 3
(R1) (A) (P) (B) (R2)
t y
2-Position S0725 (A)4 2(B)
Double u rewq

(R1)5 1 3(R2)
(P)

5 4 1 2 3
(R1) (A) (P) (B) (R2)
t y
3-Position
S0735
Closed Center (A)4 2(B)

u r e w q
(R1)5 1 3(R2)
(P)

S07A5
5 4 1 2 3 4(A) 2(B)
t (R1) (A) (P) (B) (R2)
y
4-Position 5(R1) 3(R2)
Dual 3-Port Valve u rewq
1(P)
N.C. + N.C.

S07B5
4(A) 2(B)

5(R1) 3(R2)

5 4 1 2 3 1(P)
(R1) (A) (P) (B) (R2)
t y N.O. + N.O.
Component Parts S07C5
No. Description Material 4(A) 2(B)
1 Body Zinc die-casted
2 Spool Aluminum
3 Piston Resin
5(R1) 3(R2)
4 Manual override Resin
5 Adapter plate Resin
6 Interface gasket HNBR 1(P)
7 Pilot valve assembly Refer to page 25. N.C. + N.O.
24
Series S0700
Replacement Parts
Body Base
Ported Mounted
<One-touch Fitting Assembly (For Cylinder Port)>
Applicable manifold Port size Part no.
ø2 One-touch fitting KJH02-C1

ø4 One-touch fitting KJH04-C1


Body S076
Ported SS0752
ø1/8" One-touch fitting KJH01-C1

ø5/32" One-touch fitting KJH03-C1


ø2 One-touch fitting VVQ0000-50A-C2
ø3.2 One-touch fitting VVQ0000-50A-C3
8.5 mm
pitch
ø4 One-touch fitting VVQ0000-50A-C4
Base ø1/8" One-touch fitting VVQ0000-50A-N1
SS0755
Mounted ø5/32" One-touch fitting VVQ0000-50A-N3
ø2 Barb fitting SS070-50A-20
7.5 mm
pitch
ø3.2 Barb fitting SS070-50A-32
ø4 Barb fitting SS070-50A-40
Note) Purchasing order is available in units of 10 pieces.

<Plug Connector Assembly> Body Base <Gasket, Screw Assembly> Body Base
Ported Mounted For internal pilot S0700-GS-2 Ported Mounted
S070 14A Body ported
For external pilot S0700-GS-2R
Base mounted S0700-GS-5
Lead wire length Note) Above part number consists of 10 units.
Symbol Length Each unit has one gasket and two screws.
Nil 150 mm
3 300 mm
6 600 mm
<Sub-plate>
10 1000 mm Base
Part no. Type Mounted
Note) Standard wire length of valve with plug connector is 300 mm. S0700-S-M5 For internal pilot
When ordering a lead wire length of 600 mm or longer, list the S0700-S-M5-R For external pilot
part numbers for the valve without connector and the connector
assembly.

<Pilot Valve Assembly> <SI Unit (EX510 series)> Base


Body Base
Mounted
S070P 5 B G –1 Ported Mounted EX510 S 0 01

Voltage Accessory Output specifications


Symbol Type Symbol Specifications 0 NPN output (Positive common)
5 24 VDC Nil None 1 PNP output (Negative common)
6 12 VDC –1 Stopper plate is included.

Electrical entry <Silencer Element> Body


Symbol Specifications Ported
G Grommet
Plug connector, with lead wire Element part number: S0700-82A-1
C (With light/surge voltage suppressor) 1 set includes 10 pieces. (for 5 valves)
Plug connector, without lead wire
CO (With light/surge voltage suppressor)
Note) For pilot valve assembly replacement,
refer to “Specific Product Precautions” on
page 29.

Element

PR plate

Clip
25
Series S0700
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on SMC website, http://www.smcworld.com

Manual Override How to Mount Valve

Warning Caution
The manual override is used for switching the main Tighten the bolts firmly to stop the gasket from
valve. coming away from the valve using the appropriate
torque as shown on the following table.
Push type (Tool required)
Push down on the manual override button with a tool such as a Proper tightening torque [N ·m]
small screwdriver until it stops. 0.17 to 0.23

Body ported type hole diameter ø4.2 Base mounted type hole diameter ø3.2 Body Ported Mounting screw (M2)

How to Attach/Detach Plug Connector


To attach a connector, hold the lever and connector unit between
your fingers and insert straight onto the pins of the solenoid valve When mounting a single
so that the lever’s pawl is pushed into the groove and locks. body ported valve on the
wall directly, use the
To detach a connector, remove the pawl from the groove by
following tightening torque.
pushing the lever downward with your thumb, and pull the
connector straight out.

Connector Lever

Lever pawl

Proper tightening torque [N·m]


Groove
M3 thread 0.5 to 1.0
Cover

Base Mounted Mounting screw (M2)

Note) In order not to damage the connector and cover, do not pull the
lead wire excessively (with a force of 10 N or more).

26
Series S0700
Specific Product Precautions 2
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on SMC website, http://www.smcworld.com

How to Replace One-touch Fittings How to Replace Silencers

Warning A single body ported valve has a built-in silencer.


The cylinder port fittings are a cassette for easy re- A dirty and clogged silencer may reduce cylinder speed
placement. or cause a malfunction. Replace the silencer periodically.
To replace the silencer, remove the PR plate after removing the clip,
Base Mounted and then remove the old element with a tool such as a flat blade
screwdriver.
The fittings are blocked by a clip inserted from the top
of the valve. Remove the clip with a tool such as a flat Element part number: S0700-82A-1
blade screwdriver to remove fittings. For replacement, 1 set includes 10 pieces. (for 5 valves)
insert the fitting assembly until it strikes against the
inside wall and then re-insert the clip to the specified
position.
Clip

Fitting
assembly

Element
Insert the element so that the
Applicable tube O.D. Fitting assembly part no. longer side of the element is
Applicable tube ø2 VVQ0000-50A-C2 mounted vertically.
Applicable tube ø3.2 VVQ0000-50A-C3
8.5 mm pitch
Applicable tube ø4 VVQ0000-50A-C4
(One-touch fitting) PR plate
Applicable tube ø1/8" VVQ0000-50A-N1
Applicable tube ø5/32" VVQ0000-50A-N3
Barb fitting ø2 SS070-50A-20
7.5 mm pitch Clip
Barb fitting ø3.2 SS070-50A-32
(Barb fitting)
Barb fitting ø4 SS070-50A-40
Proper tightening torque [N·m]
* Part number is for one fitting assembly. Please order it in units of 10 pieces. 0.2 to 0.25

Body Ported

The fittings are blocked by a clip. After removing the Other Tube Brands
corresponding valve and take out the clip with a tool such
as watchmakers’ flat blade screwdriver, then replace the
fittings. For mounting, insert the fitting until it strikes
Caution
against the inside wall and then insert the clip to the When using other than SMC brand tube, confirm that
specified position. the following specifications are satisfied with respect
to the tube outside diameter tolerance.
1) Nylon tube within ±0.1 mm
Fitting assembly 2) Soft nylon tube within ±0.1 mm
3) Polyurethane tube within +0.15 mm,
within −0.2 mm
Do not use tube which do not meet these outside diameter
tolerances. It may not be possible to connect them, or they may
cause other trouble, such as air leakage or the tube pulling out
after connection.

Clip
Clip

Applicable tube O.D. Fitting assembly part no.


Applicable tube ø2 KJH02-C1
Applicable tube ø4 KJH04-C1
Applicable tube ø1/8" KJH01-C1 Fitting assembly
Applicable tube ø5/32" KJH03-C1
* Part number is for one fitting assembly. Please order it in units of 10 pieces.
27
Series S0700
Specific Product Precautions 3
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on SMC website, http://www.smcworld.com

One-touch Fittings Internal Wiring Specifications

Tube attachment/detachment for One-touch fittings Caution


1) Tube attachment Light/surge voltage suppressor
1. T
 ake a tube having no flaws on its periphery and cut it off at
a right angle. When cutting the tube, use tube cutters TK-1, 2 No polarity by adopting non-polar light.
or 3. Do not use pinchers, nippers or scissors, etc. If cutting is
done with tools other than tube cutters, the tube may be cut
(−)
diagonally or become flattened, etc., making a secure

Varistor
installation impossible. Allow some extra length in the tube.
SOL.A
2. T
 he outside diameter of the polyurethane tube swells when
internal pressure is applied to it. Therefore, it may be possible LED
(+)
that the tube cannot be re-inserted into the One-touch fitting.
Check the tube outside diameter, and when the accuracy of
the outside diameter is +0.07 mm or larger for ø2, +0.15 mm Note) Coil surge voltage generated when OFF is about –60 V. Please contact
SMC separately for further suppression of the coil surge voltage.
or larger for other sizes, insert into the One-touch fitting
again, without cutting the tube to use it. When the tube is re-
inserted into the One-touch fitting, confirm that the tube goes
through the release button smoothly.
3. G
 rasp the tube, slowly push it straight (0 to 5°) into the One-
touch fitting until it comes to a stop.
Indicator light
4. A
 fter inserting the tube, pull on it lightly to confirm that it will A side
not come out. If it is not installed securely all the way into the
fitting, this can cause problems such as air leakage or the
tube pulling out.
2) Tube detachment
1. P
 ush in the release button sufficiently, pushing its collar
equally around the circumference.
2. P
 ull out the tube while holding down the release button so
that it does not come out. If the release button is not pressed Indicator light
down sufficiently, there will be increased bite on the tube and B side
it will become more difficult to pull it out.
3. W
 hen the removed tube is to be used again, cut off the
portion which has been chewed before reusing it. If the
chewed portion of the tube is used as is, this can cause Surge Voltage Intrusion
trouble such as air leakage or difficulty in removing the tube.
Caution
D
 o not apply unnecessary forces such as twisting, The surge voltage created when the power supply is cut off
pulling, moment loads, vibration and impact, etc. on could apply to the de-energized load equipment through the
fittings or tubing. output circuit. In cases where the energized load equipment
A force of 20 N or more applied to the fitting and/or tube can has a larger capacity (power consumption) and is connected
cause damage to the valve and/or fitting, crushing, bursting, or to the same power supply as the product, the surge voltage
detachment of tubing, or air leakage. could malfunction and/or damage the internal circuit
element of the product and the internal device of the output
equipment. To avoid this situation, place a diode which can
suppress the surge voltage between the COM lines of the
load equipment and output equipment.

28
Series S0700
Specific Product Precautions 4
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on SMC website, http://www.smcworld.com

How to Replace Pilot Valve How to Connect Tubing

Caution Caution
Removal <Base mounted/Barb fittings>
1) Remove the stopper plate from the adapter plate assembly by 1) Perpendicularly cut the tube to the necessary length by using
using a flat blade screwdriver on the concave of the stopper an SMC tube cutter TK-1, 2, 3 or 6.
plate. 2) Firmly insert the tube into the barb fitting. Insufficient insertion
2) Take off the pilot valve in horizontal direction. of the tube could cause the air leakage and/or disconnection of
the tube.
Mounting 3) When inserting the tube into the barb fitting, move the tube in
1) Mount the pilot valve on the adapter plate assembly. parallel to the axis of the barb fitting to avoid any excessive
side load to the fitting.
2) Insert the stopper plate into the adapter plate so that the stop-
per plate will not protrude from the end of the adapter plate.

Pilot valve assembly

Adapter plate assembly

4) Pay attention not to apply any excessive side load to the barb
fitting when removing it from the tube. When using a tube
cutter or something similar, be careful not to damage or crack
Stopper plate
the fitting.
5) Do not apply any excessive load such as tensile, compressive
or bending force to the tube once connected.

Groove

29
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

You might also like