6/5/23, 10:25 PM Print Certificate
MEENAL ENGINEERS AND CONSULTANTS
www.meenalengineers.com
CMP-319/2022 (SEC 21(2), 28, 29, 31) VALID TILL 31/12/2023,DP-5185/CPG VALID TILL
31/03/2023
Certificate No : SO-10991/1
Report of Examination & testing of Cranes/ Hydra (As per Section 29 of The Factories Act)
1 NAME OF THE OWNER/ OCCUPIER M/S. SHREE AMBIKA INFRASTRUCTURES.
2 ADDRESS OF THE FACTORY/ SITE C/O. HINDUSTAN ZINC LTD.
CLZS, CHITTORGARH (RAJASTHAN )
3 DISTINGUISHING NUMBER OR MARK , IF ANY CHAIN, ROPE , MULTIPLE SLING OR THE THE LIFTING MACHINE , HYDRA CRANE ,
CHAIN , ROPE , MULTIPLE SLING OR THE LIFTING TACKLE. REGISTRATION NO.- RJ09EA5503.
ENGINE NO - E414CDPB423617E.
CHASSIS NO - ACE0F150EP0467042.
MAKE - ACE, MODEL - F 150
BOOM LENGTH - 15.4 METER
RATED CAPACITY - 14 TONNE WITH 14 TONNE HOOK BLOCK
MANUFACTURING YEAR - 04/2023
gi al LOCATION -MOVABLE IN PLANT
s
4 DATE WHEN THE LIFTING MACHINE ,CHAIN, ROPE , MULTIPLE SLING OR THE LIFTING TACKLE WAS FIRST 2023
BROUGHT INTO USE ON SITE
er
En en
5 DATE AND NUMBER OF THE CERTIFICATE RELATING TO ANY TEST AND EXAMINATION MADE UNDER SUB-RULES FIRST TIME TESTING DONE BY MEENAL ENGINEER'S & CONSULTANTS
(1) AND (7) TOGETHER WITH THE NAME AND ADDRESS OF THE PERSON WHO ISSUED THE CERTIFICATE .
6 FOLLOWING EXAMINATIONS WERE MADE :
ne
i) UNIFORMITY OF THE DIAMETRE OF THE LINK OF ROPE/ CHAIN . PHYSICALLY CHECKED & FOUND OK
MAIN ROPE DIA - 13 MM
e
ii) LOAD HOOK OPENING & NECK SECTION. PHYSICALLY CHECKED & FOUND OK
M
iii) BOOM CONDITION PHYSICALLY CHECKED & FOUND OK
iv) NO. OF FALLS OF ROPES/ CHAIN . 04(FOUR)
v) CHECKING OF EXTERNAL SURFACE OF LINKS OF CHAIN / ROPE TO FIND CRACK , ETC. , IF ANY PHYSICALLY CHECKED & FOUND OK
vi) LOAD TEST OF THE LIFTING TACKLE LOAD TEST DONE AT 4.2 TONNE AT 4.9 METER RADIUS WITH FOUR FALLS.
vii) ASLI CONDITION PHYSICALLY CHECKED & FOUND OK
ix) ALL LIMIT SWITCH PHYSICALLY CHECKED & FOUND OK
7 PARTICULARS OF ANY DEFECTS AFFECTING EXAMINATION MADE UNDER CLAUSE (A) III SUCH THOROUGH NO DEFECT
EXAMINATION OR AFTER ANNEALING AND OF THE STEPS TAKEN TO REMEDY SUCH DEFECTS .
8 OTHER OBSERVATIONS SATISFACTORY
I certify that on 03-Jun-2023 the equipment described above was made accessible for thorough examination and for such tests as were necessary and that on the
said date, I thoroughly examined this equipment including its fittings and that the above is a true report of my examination.
Certificate Valid Till: 02-Jun-2024.
For Meenal Engineers and Consultants
Er Rajiv Singh
Competent Person Under The Factories Act
Partner/Authorized Signatory Meenal Engineers & Consultants
DISCLAIMER: This report of examination reflects the condition of the machine/equipment as on date. We accept no liability/responsibility whatsoever in case of
any accident/mishap on/with due to this machine/equipment.
https://app.meenalengineers.com/PrintInv 1/2
6/5/23, 10:25 PM Print Certificate
https://app.meenalengineers.com/PrintInv 2/2