0% found this document useful (0 votes)
26 views1 page

MCC Equipment Designation: Remove Aux Rev 4

The document outlines the equipment designation and specifications for MCC114, including various Allen Bradley components and their configurations. It includes references to electrical drawings, terminal location symbols, and notes on labeling and circuit breaker identification. Additionally, it provides information on project codes, construction status, and revision history.

Uploaded by

Pham Trien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views1 page

MCC Equipment Designation: Remove Aux Rev 4

The document outlines the equipment designation and specifications for MCC114, including various Allen Bradley components and their configurations. It includes references to electrical drawings, terminal location symbols, and notes on labeling and circuit breaker identification. Additionally, it provides information on project codes, construction status, and revision history.

Uploaded by

Pham Trien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 MCC EQUIPMENT DESIGNATION

201 251
ITEM No. MAKE TYPE
202 252 3 A206 ALLEN BRADLEY 1794-AENTR

MCC114 A211 ALLEN BRADLEY 1794-IB32 (C/W TB32)

203 PLC & MARSHALLING 253 A213 ALLEN BRADLEY 1794-OW8 (C/W TB3)
1550 155N
PANEL A219 ALLEN BRADLEY 1794-IF4I (C/W TB3)

204 24V DC SUPPLY FROM LINE 156 REFER 090-E-12195 254 Q225 TERASAKI DTCB6204C
3 A225 CISCO IE-2000-8TC-G-E

205 X2 X2 255
Q206 A206 Q206
4A 2060 FLEX I/O COMMS 206N 4A
206 X2 24V ADAPTOR COM X2 256

LINE 168 LINE 168


207 3 257

208 258
1570 157N

209 24V DC SUPPLY FROM LINE 157 REFER 090-E-12195 259

210 260
A211
1570 157N
211 X2 C35 FLEX I/O 32 INPUT C36 X2 261
X2 C43 MODULE 0 C44 X2

212 262
A213
LEGEND
1570 FLEX I/O 8 OUTPUT 157N
213 X2 C34 MODULE 1 B16 X2 263
REFER TO IEC60617 FOR ELECTRICAL DRAWING SYMBOLS.
3 REFER TO 000-E-12059 FOR ELECTRICAL IDENTIFICATION
214 264 CODES LEGEND.

215 265
TERMINAL LOCATION SYMBOLS
X2
MCC MARSHALLING TERMINAL
216 266
1750 175N

217 24V DC SUPPLY FROM LINE 175 REFER 090-E-12195 267

218 X2 X2 268
A219

1750 FLEX I/O 4 INPUT ANALOG 175N


219 C34 MODULE 2 B16 269

220 270

221 271

NETWORK SWITCH
222 272
1550 155N
080-E-14668
223 24V DC SUPPLY FROM LINE 173 REFER 090-E-12195 273

224 X2 X2 274
Q225 NS10120 Q225
4A 2250 A225 225N 4A
225 DC-A+ NETWORK SWITCH DC-A- X2 275
3
226 276

227 277

228 278
REMOVE AUX NOTES
229 279
REV 4 1. ALL FERRULE NUMBERS SHALL BE PREFIXED WITH THE
PARENT EQUIPMENT NUMBER E.G. MCC114-0180, EXCEPT
230 280
THE COMMON 24V DC/240V AC SUPPLIES THAT REMAIN
INSIDE THE FIELD TERMINAL BOX E.G. 0090 (AS SHOWN).
231 281
2. ALL I/O SUPPLY CIRCUIT BREAKERS SHALL BE PREFIXED
WITH THE PARENT EQUIPMENT NUMBER E.G. MCC114-Qxxx.
232 282
3. LABEL ON FRONT OF TERMINAL BOX SHALL READ:-

MCC114
233 283
PLC & MARSHALLING
PANEL
234 284
090-E-12085

235 285
REFER TO 003-E-12001 FOR LABEL SIZE AND DETAILS.

236 286

237 287

238 288

239 289

240 290

241 291
4 LAN EQUIPMENT - MCC114
080-E-14668
242

ED 292 INTERCONNECTION DIAGRAM

415V MCC 114 (M114C) - SP36

243
3 CT
4 293 3 SCHEMATIC DIAGRAM
090-E-12195

244
RU 294
415V MCC 114 (M114C) - PLC & MARSHALLING
TERMINATION DIAGRAM SHT 1 & 2
090-E-12085 &
090-E-12197

ST PLC 'SCD3B' PROFIBUS FIELD I/O STRUCTURE


INTERCONNECTION DIAGRAM SHT 3
090-E-12086
245

ON 295
415V MCC 114 (M114C)
090-E-12198
246
C 296 CABLE SCHEDULE

415V MCC 114 (M114C)

247
OT 297 TERMINATION DIAGRAM
090-E-12196

248
N 298
415V MCC 114 (M114C)
SINGLE LINE DIAGRAM
090-E-12194

CONTRACT NUMBER
OR PURCHASE ORDER NUMBER
9100060856
249 299

REFERENCE DOCUMENTS DOC NO


250 300 PN:APAC01.510663

CONSTRUCTION AS-BUILT COMMISSIONING AS-BUILT AP03054 - CD3 RENEWAL PROJECT


BHPIO TO COMPLETE BHPIO/REVIEWER TO COMPLETE DESIGNER/CONTRACTOR TO COMPLETE
(RED INK) (BLUE INK) 3 14.03.23 A.B.N. 46 008 700 981
ISSUED FOR CONSTRUCTION
BHPIO AURECON
COMPANY COMPANY 2 07.11.16
TRIPLE INTERCEPTOR PROJECT MCC 114 - PE0845 DRAWING STATUS REVIEW SIGNED DATE REV COMPANY COMPANY
17 May 24 Electrical: v9.1
PORT INDUSTRIAL FACILITIES - NELSON POINT
AS BUILT INFORMATION ONLY DESIGNED BY
SIGNATURE SIGNATURE
PLC REPLACEMENT PROJECT - PE0369
SERVICES - TRIPLE INTERCEPTOR
AS BUILT SIGNED DRAWN BY
1 25.08.16
NAME NAME AS BUILT
CONSTRUCTION MAY PROCEED CHECKED BY
415V MCC 114 (M114C) CONTROL SUPPLY
AP03054 - CD3 RENEWAL PROJECT PLC REPLACEMENT PROJECT - PE0369
PROJECT CODE PROJECT CODE 4 17.05.24
ISSUED FOR CONSTRUCTION
0 29.06.15
APPROVED FOR CONSTUCTION
CONSTRUCTION MAY PROCEED
EXCEPT AS NOTED
DESIGN & HSEC
APPROVED BY
SCHEMATIC DIAGRAM
THIS DRAWING HAS BEEN REVIEWED
DRAWING MARKED UP DRAWING MARKED UP
FOR GENERAL COMPLIANCE TO SCOPE
REVISION REVISION
NO CHANGE NO CHANGE NO DATE REVISION COMMENT TO INCLUDE PROJECT CODE NO DATE REVISION COMMENT TO INCLUDE PROJECT CODE REVISE AND RESUBMIT AND COMPANY STANDARDS SCALE NTS A1 DRG. NO.
090 E 12084 /4
FOR ALL REVISIONS FOR ALL REVISIONS

THIS DOCUMENT IS UNCONTROLLED WHEN PRINTED OR DOWNLOADED


AND SHOULD BE DISCARDED AFTER USE. IT IS YOUR RESPONSIBILITY TO
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 ENSURE THAT YOU USE THE MOST RECENT REVISION OF THIS DOCUMENT.

You might also like