© Journal of the Technical University - Sofia
Plovdiv branch, Bulgaria
“Fundamental Sciences and Applications”
Vol. 26, 2020
Thermal performance characteristics in plain horizontal tubes
influenced by combined wire coil and twisted tape inserts
Daniela Kostadinova1, Plamen Bonev2,
1
Department of Energy Techniques Technical University of Gabrovo, 4 Hadzhi Dimitar
Str. 5300 Gabrovo, Bulgaria Рhone: 0895419429
2
Department of Energy Techniques Technical University of Gabrovo, 4 Hadzhi Dimitar
Str. 5300 Gabrovo, Bulgaria
*
e-mail: didkamail78@abv.bg
Abstract. In this paper, heat transfer, friction factor behaviors in a tube equipped with the
combined devices between two different types of twisted tape y=2.7 and y=3.0 and a wire coil
pitch ratio are experimentally investigated. This paper presents heat transfer enhancement in
single-phase transitional flow by wire-coil insert with geometrical parameters rib height-to-
diameter ratio e/D=0.071, and rib pitch-to-height ratio p/e =7.5. The experiments are at different
measured fluid temperatures in a turbulent flow regime with Reynolds numbers ranging from 1000
to 10000 using water as the test fluid. At Reynolds number 2000 the highest Nu* is of around 5.6
1. Introduction
The main purpose of heat transfer enhancement techniques is to augment heat transfer and increase the
thermal performance of the system. The techniques can be diveded into two categories: active and passive
methods. Supplying extra energy to the fluid is used in the active methods.
Rotating the surface, mechanical auxiliary elements, constituting electrostatic areas in the flow area,
mixing fluids with mechanical accessories are active methods. The passive enhancement doesn’t acquire
any external energy. The approaches of this category take account of rough surface, surface area
extension, coated surface, and turbulator, swirl generator device. One of the most promising techniques is
insertion of turbulator or swirl generator devices. Reducing the thickness of the boundary layer is one of
the major functions of turbulator or swirl generator which could introduce better fluid mixing [1].
Wire coils and twisted tapes have taken great attention due to their low cost and promising
performance [2]. Numerous research works have been reported with taking into account the effect of coil
pitch, on heat transfer and friction characteristics, coil-wire thickness for wire coil inserts or twist ratio
and tape thickness for twisted tape inserts [2–16]. The research showed that twisted tape insert disturbs
the entire flow field while the wire coil insert mainly perturbs the flow near the wall. In heat transfer
enhancement point of view the twisted tape is more effective than wire coil inserts [18]. When we get a
crucial restriction, wire coil seem to be more useful due to its less pressure drop penalty. According to
Wang and Sunden, in order to gain better heat transfer enhancement it is useful for heat transfer
enhancement device and also for consideration of some device combinations.
The purpose of this paper is to report the results from experimental study of heat transfer and pressure
drop in the turbulent flow regime of heating water flowing in horizontal circular smooth tube.
2. Experiments
2.1. Experimental Set-up
A schematic diagram of the overall experimental set-up [17] for heat transfer and pressure drop
experiments is shown in Fig. 1. The test section consisted of a tube-in-tube heat exchanger in a counter
flow configuration, 1. The inner tube is a horizontal copper circular tube with an inside diameter of 14.0
mm and an outside diameter of 16.0 mm. The total length of the test section, for isothermal friction factor
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
measurements, was 3 m, providing a maximum length-to-inside diameter ratio ( L /Di ) of 214, while for
the heat transfer and non-isothermal friction factor measurements the length of the heating test section
was 2.0 m and this ratio was 143.
Water was used as a working fluid for both streams, with the inner fluid being cold and the annulus
fluid being hot. The temperature of the tested fluid (cold water in the inner tube) was changed in the range
5.5-50o C to insure the variation of the Prandtl number in the range 3.5 Pr 10.0 . The temperature of the
hot water in the annulus was changed in a such way to maintain the temperature difference between hot
and cold water as small as possible. In this way, the variation of the wall temperature was never greater
than 2oC at the length of the tube. Cooling of the test fluid of the inner tube and heating the water in the
annulus were performed by secondary flow loops containing water from large reservoirs. The 200-litre
reservoir 2 for annulus water was heated by an electric heater, while the reservoir 3 for the inner fluid
(also 200 litre) was heated by an electric heater or cooled by a chiller 4.
The test fluid was pumped through the system with two pumps 5 installed in parallel and used in
accordance with the flow rate requirements. From the reservoirs 2 and 3, the water flowed through a set
of flow meters 6 that measured the volume flow rate. A total of three flow meters were used, two in
parallel for the working fluid, used according to the flow rate requirements. After the flow meters, the
fluids flow through the experimental section and then back to into the reservoirs. The working fluid
passed the mixing chamber 7 and smooth tube entrance section 8 and run through the smooth or rough
test tube, followed by another mixing chamber 9 and cooler 10. An additional water tank 11 was used to
sustain the lower temperatures of the working fluid.
At both the inlet and the outlet, the tube tested was equipped with two measurement stations 12, each
one including four pressure taps set 90 deg apart in a cross section installed by drilling a 1 mm hole
through the copper tube. The static pressure from the measurement stations (the average of the tap
outputs) was connected to the differential pressure transducer 13 by nylon tubing.
For obtaining a representative inner-tube wall temperature, 18 of the 22 thermocouples were placed
along the length of the inner-tube’s outer-wall at nine, equally spaced stations. The remaining
thermocouples were placed at the in- and outlets of the test section. All readings from thermocouples and
differential pressure transducer were logged by data-acquisition system 14.
5 6 11
V
4
12 8 1 12 9
7
p 13 10
V 6 V
3
NI CompactDAQ-9172
5 14
Figure 1. Experimental set-up.
3. Data Reduction
Experiments have been conducting in the laminar, transitional and turbulent regimes under isothermal and
heating flow conditions. The experimental data were used to investigate the effect of heating on the
2
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
entrance and fully-developed friction factors from the laminar to turbulent regions and to establish the
validity of the isothermal and non-isothermal correlations wellestablished in the literature.
3.1. Fanning Friction Factor and Heat transfer
The isothermal and non-isothermal pressure drop studies were conducted at different temperatures of the
water in the range 5.5-50 oC over the range of Reynolds number 1.2 103 Re 1.7 104 . The pressure
drop data were converted to the Fanning friction factor by the equation
2 Di2 p
f (1)
32 L V 2
where p is obtained from the readings of the differential pressure transducer, and V - from the
measurements of the volume flow rate. The fluid properties were calculated at the average inner-tube
fluid temperature, except the water density which was calculated at the inlet temperature.
Heat transfer studies were carried out to obtain values for the inner’s tube average heat transfer
coefficient h i and annulus heat transfer coefficient h o . Since the wall temperature was measured, the
individual coefficient was determined from the equation
Q h i Ai Tm, i h o A o Tm, o , (2)
where Q is the average heat flow of Qi (based on cooling water) and Qo (based on heating water) given
by
Qi mi c p , i (Ti , o Ti , i ) (3)
and
Qo mo c p ,o (To, i To, o ) . (4)
Only those runs for which the heat balance error, given by
Qi Qo
hb 100% , (5)
Qi Qo / 2
was less than 5% were processed for evaluation of h i and h o . The log-mean temperature differences
Tm, i and Tm, o were used to determine the heat transfer coefficients h i and h o from Eq. (2), where
Tm,i was defined by
3
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
Tx o Tx L
Tm,i , (6)
Tx o
ln
Tx L
where Tx o Tw (o) Ti, i and Tx L Tw (L) Ti, o .
It became clear from the wall temperature measurements along the length of the tube that the variation
of the wall temperature along the length of the tube could be outlined with a linear correlation
Tw ( x) a1 a2 x with constants a1 and a2 calculated for each regime. The values of the temperatures
Tw (o) and Tw (L) have been calculated by extrapolation of the linear correlation for x o and x L . The
influence of the wall resistance on the heat transfer coefficient in all cases was found to be negligible.
4. Exposition
4.1. Results and discussion
The experimental results are presented with isothermal friction factor results and heat transfer results. Fig.
2 show the experimental friction factor results at y=3.0 simultaneously at isothermal conditions.
Figure 2. The variation of adiabatic friction factors with Reynolds number.
Fig. 3 shows friction factor augmentation f* f / f s produced by the wire coil. The tendency of
friction factor behaviour commented in the foregoing discussion is very clean expressed.
4
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
Figure 3. The variation of the ratio f* with Reynolds number.
As seen, for Reynolds number in the range 1100– 2100, the friction factor ratio f* decreases from 11.0
to 4.0. After that it gradually decreases with the increase of Re .
Figure 4. The variation of Nusselt number with Reynolds number for different Prandtl numbers.
Figure 5. The variation of Nusselt number with Reynolds number for different Prandtl numbers.
5
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
Fig. 4 and fig.5 show the experimental Nusselt numbers for a fully developed hydrodynamic boundary
layer at the inlet but with a thermal boundary layer still developing. A total of 150 data points represents
the data in transition and turbulent regimes.
Nusselt number augmentation is defined by the ratio Nu* Nu /Nus at the same Reynolds and
Prandtl numbers. Fig. 6 shows the ratio Nu* for the wire-coil inserts studied. In the transition region
(1 100 < Re < 4 000) Nu * reaches its maximum values 5.6 and after that it decreases gradually and then
remains constant.
Figure 6. The variation of the ratio Nu* with Reynolds number.
5. Conclusion
A comprehensive experimental study has been carried out on a wire coils inserted in a smooth tube, with
geometrical parameters e /Di 0.071 and p / e 7.5 , covering transition and turbulent flow regimes:
Re = 1 100-10 000 and Pr = 3.7-10. A huge number of experimental points for friction factor and heat
transfer coefficient have been obtained. As seen from the Figs. 3 and 6, the ratios f* and Nu* have a
maximum value at one and the same Reynolds number around 2100.
The variation of this ratios with Reynolds number are required to be able to evaluate the real benefit of
the use of this particular heat transfer augmentation technique into practice.
References
[1] A. Dewan, P. Mahanta, S.K. Raju, S.K. Kumar, Review of passive heat transfer augmentation
techniques, Journal Power Energy 218 (2004) 509–525.
[2] L. Wang, B. Sunden, Performance comparison of some tube inserts, International Communication
Heat and Mass Transfer 29 (2002) 45–56.
[3] R.C. Prasad, J. Shen, Performance evaluation using exergy analysis-application to wire-coil inserts in
forced convection heat transfer, International Journal of Heat and Mass Transfer 37 (1994) 2297–2303.
[4] M.E. Arici, H. Asan, Enhancement of turbulent flow heat transfer in tubes by means of wire coil
inserts, ASME, PD Advance in Heat Transfer 64 (1994) 113–117.
[5] K.N. Agrawal, M.A. Anil Kumar, A. Behabadi, H.K. Varma, Heat transfer augmentation by coiled
wire inserts during forced convection condensation of R-22 inside horizontal tubes, International Journal
of Multiphase Flow 24 (1998) 635–650.
[6] H.Y. Kim, S. Koyama, W. Matsumoto, Flow pattern and flow characteristics for counter-current two-
phase flow in a vertical round tube with wire coil insert, International Journal of Multiphase Flow 27
(2001) 2063–2081.
[7] H.R. Rahai, H.T. Vu, M.H. Shojaeefard, Mixing enhancement using a coil insert, Applied Thermal
Engineering 21 (2001) 303–309.
6
!
Copyright © 2020 by Technical University - Sofia, Plovdiv branch, Bulgaria Online ISSN 2603-459X
[8] H. Inaba, N. Haruki, Heat transfer enhancement of water flow in a straight pipe with drag reduction
surfactant by using wire coil, Transaction JSME, Series B 68 (2002) 481–488.
[9] H.R. Rahai, T.W. Wong, Velocity field characteristics of turbulent jets from round tubes with coil
inserts, Applied Thermal Engineering 22 (2002) 1037–1045.
[10] V. Ozceyhan, Conjugate heat transfer and thermal stress analysis of wire coil inserted tubes that are
heated externally with uniform heat flux, Energy Conversion and Management 46 (2005) 1543–1559.
[11] P. Naphon, P. Sriromruln, Single-phase heat transfer and pressure drop in the micro-fin tubes with
coiled wire insert, International Communications in Heat and Mass Transfer 33 (2006) 176–183.
[12] P. Naphon, Effect of coil-wire insert on heat transfer enhancement and pressure drop of the
horizontal concentric tubes, International Communications in Heat and Mass Transfer 33 (2006) 753–
763.
[13] T.S. Ravigururajan, A.E. Bergles, Development and verification of general correlations for pressure
drop and heat transfer in single-phase turbulent flow in enhanced tubes, Experimental Thermal and Fluid
Science 13 (1996) 55–70.
[14] K. Yakut, B. Sahin, The effects of vortex characteristics on performance of coiled wire turbulators
used for heat transfer augmentation, Applied Thermal Engineering 24 (2004) 2427–2438.
[15] A. Garcıa, J.P. Solano, P.G. Vicente, A. Viedma, Enhancement of laminar and transitional flow heat
transfer in tubes by means of wire coil inserts, International Journal Heat and Mass Transfer 50 (2007)
3176–3189.
[16] M.A. Akhavan-Behabadi, M.R. Salimpour, V.A. Pazouki, Pressure drop increase of forced
convective condensation inside horizontal coiled wire inserted tube, International Communications in
Heat and Mass Transfer 35 (2008) 1220–1226.
[17] Zimparov, V.D., Bonev, P.J., Petkov, V.M., Transitional Heat Transfer and Pressure Drop in Plain
Horizontal Tubes, International Review Chememical Engineering (I.RE.CH.E.), 2015, 7(2), 37-44. ISSN
2035-1755
[18] S. Eiamsa-ard at all ,Influence of combined non-uniform wire coil and twisted tape inserts on
thermal performance characteristics, International Communications in Heat and Mass Transfer 37 (2010)
850–856.