Drawing Detail 4
Drawing Detail 4
_____________________
THESE DRAWINGS HAVE BEEN AUTOMATICALLY GENERATED FROM INFORMATION THAT IS BASED ONLY ON
CALCULATED STRENGTH REQUIREMENTS. THE DRAWING SHEETS ARE A REPRESENTATION OF THE DESIGN OUTPUT
IN A SCHEMATIC FORM AND ARE NOT FOR CONSTRUCTION. ALL DETAILS SHOULD BE REVIEWED FOR COMPLIANCE
WITH LOCAL DETAILING CODES AND OTHER REQUIREMENTS.
THE INFORMATION ON THESE DRAWINGS MUST BE CHECKED BY A QUALIFIED AND EXPERIENCED ENGINEER. THE
ENGINEER MUST INDEPENDENTLY VERIFY THE RESULTS AND TAKE PROFESSIONAL RESPONSIBILITY FOR THE
FINAL INFORMATION THAT IS PRESENTED.
CONSIDERABLE TIME, EFFORT AND EXPENSE HAVE GONE INTO THE DEVELOPMENT AND TESTING OF THIS
SOFTWARE. HOWEVER, THE USER ACCEPTS AND UNDERSTANDS THAT NO WARRANTY IS EXPRESSED OR IMPLIED BY
THE DEVELOPERS OR THE DISTRIBUTORS ON THE ACCURACY OR THE RELIABILITY OF THIS PRODUCT.
LIST OF DRAWINGS
NO DESCRIPTION DATE
DRAWING
LIST OF DRAWINGS
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-01
SCALE
Ln1 Ln2 LnN
Width
d
h
h
G F E H E E H E F G
TYPICAL LAP TYPICAL LAP TYPICAL LAP
(SEE NOTE 5) (SEE NOTE 5) (SEE NOTE 5)
ZONE A ZONE B ZONE C ZONE B ZONE A ZONE A ZONE B ZONE C ZONE B ZONE A ZONE A ZONE B ZONE C ZONE B ZONE A
Depth
NOTES:
1. SEE BEAM SCHEDULE FOR STIRRUP TYPE AND SPACING.
2. ZONE A LENGTH SHALL BE TWICE THE BEAM DEPTH, d.
3. THE FIRST STIRRUP IN ZONE A SHALL BE LOCATED 50mm MAXIMUM FROM THE FACE OF THE SUPPORT.
4. LAP SPLICES SHALL NOT BE LOCATED WITHIN THE BEAM/COLUMN JOINT, NOR WITHIN A DISTANCE OF 2H.
5. LAP SPLICE LENGTH SHALL NOT BE LESS THAN 300mm.
90 DEG HOOK
LARGER DIM OF COL
MAX OF H3/6 OR
(450 mm MIN)
VERTICAL COLUMN
REINFORCEMENT
TYPICAL LAP
TIES ZONE B
H3
NO DESCRIPTION DATE
VERTICAL COLUMN
REINFORCEMENT
TYPICAL LAP
TIES ZONE B
H2
DRAWING
STANDARD DETAILS
LARGER DIM OF COL
MAX OF H2/6 OR
(450 mm MIN)
TIES ZONE ATIES ZONE CTIES ZONE A
STRUCTURE
PROJECT
CSIDETAIL
(TIES NOT SPECIFIED IN SCHEDULE)
VERTICAL COLUMN
REINFORCEMENT
CLIENT
TYPICAL LAP
TIES ZONE B
H1
CSIDETAIL USER
CONSULTANT
LARGER DIM OF COL
MAX OF H1/6 OR
(450 mm MIN)
TIES ZONE A
DATE
DESIGNED BY NA
CHECKED BY AH
Concrete Column Typical Elevation (Seismic) Column Section-A
S-02
SCALE
B
A B C D
15000 mm
6000 mm
2CB1S3
2CB2S3
2CB2S3
2CB1S3
A
3000 mm
2CB1S2
2CB2S2
2CB2S2
2CB1S2
NO DESCRIPTION DATE
6000 mm
DRAWING
2CB1S1
2CB2S1
2CB2S1
2CB1S1
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
Floor Framing Plan - Story2 (EL. 6000 mm)
(Scale = 1:50)
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-03
SCALE
B
A B C D
15000 mm
6000 mm
1CB1S3
1CB2S3
1CB2S3
1CB1S3
A
3000 mm
1CB1S2
1CB2S2
1CB2S2
1CB1S2
NO DESCRIPTION DATE
6000 mm
DRAWING
1CB1S1
1CB2S1
1CB2S1
1CB1S1
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
Floor Framing Plan - Story1 (EL. 3000 mm)
(Scale = 1:50)
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-04
SCALE
A B C D
15000 mm
6000 mm
3
15000 mm
3000 mm
2
NO DESCRIPTION DATE
DRAWING
STRUCTURE
1
PROJECT
CSIDETAIL
Floor Framing Plan - Base (EL. 0 mm)
(Scale = 1:50)
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-05
SCALE
A B C D
15000 mm
6000 mm 3000 mm 6000 mm
Section A - Story2
(Scale = 1:25)
1 2 3 4
15000 mm
6000 mm 3000 mm 6000 mm
NO DESCRIPTION DATE
Section B - Story2
(Scale = 1:40)
A B C D
15000 mm
6000 mm 3000 mm 6000 mm
DRAWING
SLAB SECTIONS (1 OF 2)
STRUCTURE
(EL. 3000 mm)
200 mm
PROJECT
CSIDETAIL
CLIENT
Section A - Story1
(Scale = 1:25)
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-06
SCALE
1 2 3 4
15000 mm
6000 mm 3000 mm 6000 mm
Section B - Story1
(Scale = 1:40)
NO DESCRIPTION DATE
DRAWING
SLAB SECTIONS (2 OF 2)
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-07
SCALE
CONCRETE BEAM REBAR TABLE (SEISMIC)
SPAN SECTION SIZE LONGITUDINAL BARS STIRRUPS
TYPICAL
BEAM ID SPAN NO. LENGTH, L1 (MM) L2 (MM) (ZONE A AND ZONE B ARE SIMILAR TO ZONE C, UNLESS OTHERWISE INDIC
WIDTH DEPTH ELEVATIONS
LC (MM) A B C D E F G H ZONE A ZONE B ZONE C
(MM) (MM)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 3-20 3-20
1 5600 250 450 2-14 - - - - 1400 - A - A ELEVATION 3S
(748) (723) (748)
(0.5) (0.3)
25-10 @ 100 MM TYPE
2-20 3-20
2CB1 2 2600 250 450 - - 2-20 - - - - 650 A - - ELEVATION 3S
(929) (723)
(0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 2-20 3-20
3 5600 250 450 2-14 2-20 - - - 1400 1400 A - A ELEVATION 3S
(748) (929) (748)
(0.5) (0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 3-20 3-20
1 5600 250 450 2-14 - - - - 1400 - A - A ELEVATION 3S
(890) (852) (884)
(0.5) (0.3)
25-10 @ 100 MM TYPE
2-20 3-20
2CB2 2 2600 250 450 - - 2-20 - - - - 650 A - - ELEVATION 3S
(1,097) (852)
(0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 2-20 3-20
3 5600 250 450 2-14 2-20 - - - 1400 1400 A - A ELEVATION 3S
(890) (1,097) (884)
(0.5) (0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 3-20 3-20
1 5600 250 450 2-14 - - - - 1400 - A - A ELEVATION 3S
(913) (661) (668)
(0.5) (0.3)
25-10 @ 100 MM TYPE
2-20 3-20
1CB1 2 2600 250 450 - - 2-20 - - - - 650 A - - ELEVATION 3S
(965) (661)
(0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 2-20 3-20
3 5600 250 450 2-14 2-20 - - - 1400 1400 A - A ELEVATION 3S
(913) (965) (668)
(0.5) (0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 3-20 3-20
1 5600 250 450 2-18 - - - - 1400 - A - A ELEVATION 3S
(1,077) (774) (787)
(0.5) (0.3)
25-10 @ 100 MM TYPE
4-20 3-20
1CB2 2 2600 250 450 - - - - - - - 650 A - - ELEVATION 3S
(1,142) (774)
(0.3)
10-10 @ 100 MM TYPE 17-10 @ 200 MM TYPE
2-20 4-20 3-20
3 5600 250 450 2-18 - - - - 1400 1400 A - A ELEVATION 3S
(1,077) (1,142) (787)
(0.5) (0.3)
NO DESCRIPTION DATE
DRAWING
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-08
SCALE
A
1 2 3 4
15000 mm
6000 mm 3000 mm 6000 mm 2-20A+2-14B
(EL. 6000 mm)
A
C
400 mm 400 mm 375 mm
450 mm
1525 mm 1675 mm 1300 mm 1800 mm 1400 mm
375 mm 400 mm 400 mm
1400 mm 1800 mm 1300 mm 1675 mm 1525 mm 10@105 mm
2-20A+2-14B 2-20C+2-20D 2-20C+2-20D 2-20A+2-14B
(EL. 6000 mm)
200 mm
2CB1:Elevation 2CB1:Section A
(Scale = 1:40) (Scale = 1:15)
A A
2-20C+2-20D 2-20C+2-20D
(EL. 6000 mm) (EL. 6000 mm)
450 mm
450 mm
10@105 mm 10@105 mm
NO DESCRIPTION DATE
2CB1:Section B 2CB1:Section C
(Scale = 1:15) (Scale = 1:15)
DRAWING
STRUCTURE
450 mm
375 mm
1400 mm 1800 mm
1525 mm 1675 mm 1300 mm
400 mm
1300 mm
400 mm
1675 mm 1525 mm
1800 mm 1400 mm
10@105 mm
CSIDETAIL
2-20A+2-14B 2-20C+2-20D 2-20C+2-20D 2-20A+2-14B
(EL. 6000 mm)
200 mm
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-09
SCALE
B B
2-20C+2-20D 2-20C+2-20D
(EL. 6000 mm) (EL. 6000 mm)
450 mm
450 mm
10@105 mm 10@105 mm
3-20E 3-20E
250 mm 250 mm
2CB2:Section B 2CB2:Section C
(Scale = 1:15) (Scale = 1:15)
1 2 3 4
15000 mm
6000 mm 3000 mm 6000 mm 2-20A+2-14B
(EL. 3000 mm)
A
C
400 mm 400 mm 375 mm
450 mm
1525 mm 1675 mm 1300 mm 1800 mm 1400 mm
375 mm 400 mm 400 mm
1400 mm 1800 mm 1300 mm 1675 mm 1525 mm 10@105 mm
2-20A+2-14B 2-20C+2-20D 2-20C+2-20D 2-20A+2-14B
(EL. 3000 mm) NO DESCRIPTION DATE
200 mm
1CB1:Elevation 1CB1:Section A
(Scale = 1:40) (Scale = 1:15)
DRAWING
STRUCTURE
2-20C+2-20D 2-20C+2-20D
(EL. 3000 mm) (EL. 3000 mm) PROJECT
450 mm
450 mm
10@105 mm 10@105 mm
CSIDETAIL
CLIENT
3-20E 3-20E
250 mm 250 mm
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-10
SCALE
B
1 2 3 4
15000 mm
6000 mm 3000 mm 6000 mm 2-20A+2-18B
(EL. 3000 mm)
A
C
400 mm 375 mm
450 mm
3200 mm 1700 mm 1800 mm 1400 mm
375 mm 400 mm
1400 mm 1800 mm 1700 mm 3200 mm 10@105 mm
2-20A+2-18B 4-20C 4-20C 2-20A+2-18B
(EL. 3000 mm)
200 mm
1CB2:Elevation 1CB2:Section A
(Scale = 1:40) (Scale = 1:15)
B B
4-20C 4-20C
(EL. 3000 mm) (EL. 3000 mm)
450 mm
450 mm
10@105 mm 10@105 mm
NO DESCRIPTION DATE
1CB2:Section B 1CB2:Section C
(Scale = 1:15) (Scale = 1:15)
DRAWING
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-11
SCALE
A B C D
15000 mm
6000 mm
3000 mm
NO DESCRIPTION DATE
DRAWING
PROJECT
CSIDETAIL
Concrete Column Layout - Base (EL. 0 mm)
(Scale = 1:50)
CLIENT
CSIDETAIL USER
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-12
SCALE
Base
Story1
Story2
400 MMX400 MM COLUMN SIZE
A SECTION
REINFORCING
8-20 (2,141.93)
CC1
A SECTION
REINFORCING
8-18 (1,729.03)
Concrete Column Schedule
CC2
A SECTION
REINFORCING
8-16 (1,600.00)
CC3
SCALE
DATE
0
NO
CHECKED BY
DESIGNED BY
PROJECT NUMBER
CLIENT
AH
NA
PROJECT
DRAWING
S-13
STRUCTURE
DESCRIPTION
CONSULTANT
CSIDETAIL
NEW DRAWING GENERATED
AND TABLES
CSIDETAIL USER
DETAILING-01
DETAILING OF SLABS AND BEAMS
CONCRETE COLUMN SCHEDULES
24/11/2023
STORY2 STORY2
(EL. 6000 MM) (EL. 6000 MM)
10@100 mm10@100 mm
10@100 mm10@100 mm
B
3000 mm
3000 mm
10@150 mm
10@150 mm
10@100 mm10@100 mm 10@100 mm
8-20 8-16
A A
3000 mm
3000 mm
10@150 mm
10@150 mm
STORY2
400 mm 400 mm 400 mm 400 mm 400 mm
(EL. 6000 MM)
10@100 mm10@100 mm
2-16 2-20 2-16 2-18 2-16
16 20 16 18 16
400 mm
400 mm
400 mm
400 mm
400 mm
16 16 20 20 16 16 18 18 16 16
10@100 mm
10@100 mm
16 20 16 18 16
2-16 2-20 B 2-16 2-18 2-16
NO DESCRIPTION DATE
3000 mm
CC1:Elevation CC1:Section A CC1:Section B CC2:Section A CC2:Section B CC3:Elevation CC3:Section A 0 NEW DRAWING GENERATED 24/11/2023
10@150 mm
(Scale = 1:25) (Scale = 1:15) (Scale = 1:15) (Scale = 1:15) (Scale = 1:15) (Scale = 1:25) (Scale = 1:15)
10@100 mm10@100 mm 10@100 mm
STORY1
(EL. 3000 MM)
DRAWING
8-18
CONCRETE COLUMN ELEVATIONS
AND SECTIONS
STRUCTURE
10@150 mm
PROJECT
CSIDETAIL
10@100 mm
CLIENT
CSIDETAIL USER
CC2:Elevation
(Scale = 1:25)
CONSULTANT
DATE
DESIGNED BY NA
CHECKED BY AH
S-14
SCALE