JPA Series Pricing Scale Manual Instruction: JSB-30kg

The document provides instructions for setting the capacity, resolution, calibration, zero tracking, vibration filtering, power supply, rounding, and short circuit correction on a JPA series pricing scale. It details the specific button presses and values to input at each step of the configuration process.

Uploaded by

Bayu Purnomo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
257 views3 pages

JPA Series Pricing Scale Manual Instruction: JSB-30kg

The document provides instructions for setting the capacity, resolution, calibration, zero tracking, vibration filtering, power supply, rounding, and short circuit correction on a JPA series pricing scale. It details the specific button presses and values to input at each step of the configuration process.

Uploaded by

Bayu Purnomo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

JSB-30kg

JPA Series Pricing Scale Manual Instruction

JPA Series Pricing Scale Manual Instruction


Set Capacity and resolution
1. Set Capacity
Input password“5271388”, then press[TARE] key to confirm and enter
capacity setting, when in the zero interface. The weight screen will display“-rng-“,The
unit price screen will display the current capacity. Input the capacity in “kg” that you
need, then press[TARE] key to confirm and enter the next resolution setting.
2. Set Resolution.
The weight screen displays“-fd-”,The unit price screen will display the

1
JSB-30kg

current resolution. Input the resolution in “g” that you need, then
press [TARE] key to confirm. Open the scale again after the scale display
the self-check information.
Calibration.
Input password“5271388”,then press [SAVE]key to confirm and enter
the calibration when in the zero interface. The amount screen will display
“CAL”. The unit price screen will display the current calibration weight.
Input the calibration weight in “kg” that you need, then put the
corresponding weight on the pan. Press [SAVE] key to confirm after the
value of weight stable. 。
Set Menu.
1. Set zero tracking.
When in the zero interface, input the password“5271388”,then press[ZERO]key to
confirm and enter the zero tracking setting. The weight screen display“ACC1”, then
display the current tracking value(factory set as 0.5d), Press [M1] or decimal key to
select the zero tracking value that you need, press[TARE]key to confirm and enter to
next setting for the filter of anti vibration and wind.
2. Set the filter of anti vibration and wind.
The screen display“ACC2”, then display“FIL3”,Press[M1] or decimal
key to select the filter value that you need(factory always set“FIL1”),
Press [TARE] key to confirm and enter the next power setting.
3. Set Power.
The screen display“SUPPLY”, Press[M1] or decimal key to switch HALF or FULL. Press
[TARE] key to confirm and enter the next rounding setting.
HALF:Mean the load cell supply power indirectly, it can save power, but the loading
reaction is slow in the zero.
FULL:Mean the load cell supply power with full wave, power supply is
Large, the loading reaction is fast in the zero.

2
JSB-30kg

3. Set Rounding
The screen display“round”,Press[M1] or decimal key to choose. NO: Means the
mount no rounding; YES:Means the amount can rounding.
After choose, press [TARE] key to confirm and enter the correcting of short circuit
setting.
4. Set the correcting of short circuit.
The screen display “SHOrt”,Press[M1] or decimal key to choose. NO: means correct
directly; YES: Means need open the cover to correct. After choose, press [TARE] key to
confirm.