0% found this document useful (0 votes)
45 views7 pages

135-Fr-En - Hydrus

The document describes an ultrasonic water meter called HYDRUS. It has features like long-term stability, leak and pipe burst detection, and accuracy without being affected by particles in the water. It provides flow and volume measurements, has battery power lasting up to 16 years, and communication options like radio, M-Bus or pulse output.

Uploaded by

amkhalifa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views7 pages

135-Fr-En - Hydrus

The document describes an ultrasonic water meter called HYDRUS. It has features like long-term stability, leak and pipe burst detection, and accuracy without being affected by particles in the water. It provides flow and volume measurements, has battery power lasting up to 16 years, and communication options like radio, M-Bus or pulse output.

Uploaded by

amkhalifa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

HYDRUS

ULTRASONIC METER

APPLICATION
HYDRUS is a static water meter based on the ultrasonic technology. This
technology enables accurate calculation of water consumption and eliminates
measuring deviations caused by sand, suspended particles or air pockets.

FEATURES
4 Long-term stability under difficult conditions
4 Leak and pipe burst detection
4 MID approval up to R=400 (cold water) and R=160 (hot water)
4 No straight line required
4 No measurement of air
4 Insensitive to scale and sand
4 Installation in any position
4 Battery lifetime up to 16 years
4 Available in cold water version and hot water version
4 Available with integrated radio 434 or 868 MHz, M-Bus or pulse
4 Data communication in Prios, Real data or Open Metering protocol
(selectable OMS Generation 3 profile A or OMS Generation 4 profile B)
HYDRUS
ULTRASONIC METER

GENERAL
HYDRUS
Medium temperature range °C +1 ... +50 (cold water) / +1 ... +90 (hot water)
Ambient operating temperature °C +1 ... +70
Ambient storage temperature °C -10 ... +70 (>35 °C max. 4 weeks)
Nominal pressure PN bar 16
Power supply 2 x 3.6 VDC lithium-batteries (only 1 battery with M-Bus possible)
1 1
Battery lifetime T30 /T50 Up to 12 years (1 battery), up to 16 years (2 batteries)
Battery lifetime T901 Up to 12 years (all interfaces)
Interfaces Optical, radio (434 or 868 MHz), M-Bus, Pulse
Data storage For events and consumption values
Protection class IP 68
1
depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation

TECHNICAL DATA DISPLAY


HYDRUS
Display indication LCD, 8-digit
Units DN 15 - DN 32 Flow and volume (m³ + 3 digits after the decimal point)
Units DN 40 + DN 50 Flow (m³ + 3 digits after the decimal point); Volume (m³ + 2 digits after the decimal point)
Volume2 - flow - mediums temperature - display test2 - current error and alarm status2 - date
Values displayed (depending on - primary and secondary address - radio signal ON/OFF - battery lifetime2 - accounting day -
configuration) error hour counter - pulse values - software checksum2
2
Display according to approval (always on)

INTERFACES
HYDRUS
For configuration of display information and radio telegram, to switch to the various display
Optical loops
434 or 868 MHz, Prios, Real data, Open Metering Standard (OMS-Generation 3, Profile A, or
Radio OMS-Generation 4, Profile B, selectable)
2400 Baud (adjustable to 300 Baud), configurable telegram, cable length 1.5 m, power
M-Bus supply only via built-in battery
Pulse (Open collector) 2 configurable pulse outputs, cable length 1.5 m

VOLUME- / PULSE OPEN COLLECTOR


HYDRUS
Max. input voltage V 30
Max. input current mA 27
Max. voltage drop at active
output V/mA 2/27
Max. current through inactive
output μA/V 5/30
Max. reverse voltage without
destroying outputs V 6
Pulse rates l/pulse Decadic 0.1 ... 100
Pulse output 1 variants Total volume or forward volume
Pulse output 2 variants Forward volume, direction3 or error
Pulse duration Depending on device configuration4
Pulse break Depending on device configuration4
Pulse frequency Depending on device configuration4
3
when total volume on pulse output 1, only direction possible on pulse output 2
4
detailed description on request

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 2
HYDRUSDN 15 - 20
ULTRASONIC METER

TECHNICAL DATA*
Nominal diameter DN mm 15 15 15 20 20
Nominal flow rate Q3 m³/h 2.5 2.5 2.5 4 4
Overall length L mm 110 165 170 130 190
Overload flow rate Q4 m³/h 3.125 3.125 3.125 5 5
Transitional flow rate Q2 l/h 16 16 16 25.6 25.6
Minimum flow rate Q1 l/h 10 10 10 16 16
Starting flow rate l/h 2.6 2.6 2.6 4.3 4.3
Pressure loss at Q3 bar 0.33 0.33 0.33 0.3 0.3
*
at dynamic range R=250 / further overall lengths on request

APPROVAL
DN 15 - 20
Approval MID LNE 14586 | OIML R49 | EN 14154 | TVO | KTW | ACS | WRAS
Dynamic range (Q3/Q1) - Q3 2.5
m³/h (T30 - T50) R 160 / 200 / 250 / 315 / 400
Dynamic range (Q3/Q1) - Q3 4
m³/h (T30 - T50) R 160 / 200 / 250 / 315 / 400
Dynamic range (Q3/Q1) - Q3 1.6
- 4 m³/h (T90) R 160 / 200

DIMENSIONS

Nominal diameter DN mm 15 15 15 20 20
Nominal flow rate Q3 m³/h 2.5 2.5 2.5 4 4
Overall length L mm 110 165 170 130 190
Counter length L1 mm 88 88 88 88 88
Counter width B mm 94 94 94 94 94
Overall length with coupling L2 mm 190 245 250 230 290
Connection thread on meter inch G¾B G¾B G¾B G1B G1B
Connection thread of coupling inch R½ R½ R½ R¾ R¾
Height H1 mm 67 67 67 65 65
Weight without coupling
(approx.) kg 0.8 1 1 0.9 1.1
Weight with coupling (approx.) kg 1 1.2 1.4 1.3 1.5
Height H mm 32 32 32 34 34

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 3
HYDRUSDN 15 - 20
ULTRASONIC METER

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph Typical error graph

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 4
HYDRUSDN 25 - 50
ULTRASONIC METER

TECHNICAL DATA*
Nominal diameter DN mm 25 32 25 32
Nominal flow rate Q3 m³/h 6.3 6.3 10 10
Overall length L mm 260 260 260 260
Overload flow rate Q4 m³/h 7.87 7.87 12.5 12.5
Transitional flow rate Q2 l/h 50.4 50.4 80 80
Minimum flow rate Q1 l/h 31.5* 31.5 50* 50*
Starting flow rate l/h 10 10 10 10
Pressure loss at Q3 bar 0.25 0.25 0.55 0.55

Nominal diameter DN mm 40 40 50 50 50
Nominal flow rate Q3 m³/h 10 16 16 25 25
Overall length L mm 300 300 270 270 300
Overload flow rate Q4 m³/h 12.5 20 20 31.25 31.25
Transitional flow rate Q2 l/h 80 128 128 200 200
Minimum flow rate Q1 l/h 50 80* 80 125* 125
Starting flow rate l/h 16 16 25 25 25
Pressure loss at Q3 bar 0.25 0.4 0.1 0.25 0.25

* at dynamic range R=200; for other dynamics please contact your Diehl Metering agency.

APPROVAL
DN 25 - 50
Approval MID LNE 14586 | OIML R49 | EN 14154 | TVO | KTW | ACS | WRAS
Dynamic range (Q3/Q1) - Q3 6.3
m³/h (T30 - T50) R 40 / 807 / 160 / 200
Dynamic range (Q3/Q1) - Q3 10
m³/h (T30 - T50) R 40 / 807 / 160 / 200 / 250
Dynamic range (Q3/Q1) - Q3 16
m³/h (T30 - T50) R 40 / 80 / 160 / 200 / 250 / 3158 / 4008
Dynamic range (Q3/Q1) - Q3
25m³/h (T30 - T50) R 40 / 80 / 160 / 200 / 250 / 315 / 400
Dynamic range (Q3/Q1) - Q3 6.3
- 25 m³/h (T90) R 40 / 80 / 160
7
variant DN 25 with body length 135 mm and 150 mm only in R 80
8
not for DN 50

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 5
HYDRUSDN 25 - 50
ULTRASONIC METER

DIMENSIONS

Nominal diameter DN mm 25 32 25 32
Nominal flow rate Q3 m³/h 6.3 6.3 10 10
Overall length L mm 260 260 260 260
Counter length L1 mm 92 92 92 92
Counter width B mm 94 94 94 94
DIMENSIONS - THREAD . . . .
Overall length with coupling L2 mm 380 380 380 380
Connection thread on meter inch G1¼B G1½B G1¼B G1½B
Connection thread of coupling inch R1 R1¼ R1 R1¼
Height H1 mm 84 84 84 84
Weight without coupling
(approx.) kg 1.6 1.8 1.6 1.8
Weight with coupling (approx.) kg 2.2 2.4 2.2 2.4
Height H mm 26 26 26 26
DIMENSIONS - FLANGE . . . .
Flange diameter D mm 115 140 115 140
Hole circle diameter K mm 85 100 85 100
Number of screwholes pcs 4 4 4 4
Screwhole diameter D1 mm 14 18 14 18
Height H mm 50 62.5 50 62.5
Height H1 mm 84 84 84 84
Width F mm 100 125 100 125
Weight with flanges (approx.) kg 3.45 4.7 3.45 4.7

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 6
HYDRUSDN 25 - 50
ULTRASONIC METER

Nominal diameter DN mm 40 40 50 50 50
Nominal flow rate Q3 m³/h 10 16 16 25 25
Overall length L mm 300 300 270 270 300
Counter length L1 mm 92 92 92 92 92
Counter width B mm 94 94 94 94 94
DIMENSIONS - THREAD . . . . .
Overall length with coupling L2 mm 440 440 390 390 420
Connection thread on meter inch G2B G2B G2½B G2½B G2½B
Connection thread of coupling inch R1½ R1½ R2 R2 R2
Height H1 mm 87 87 90 90 90
Weight without coupling
(approx.) kg 3.05 3.05 3.9 3.9 4.05
Weight with coupling (approx.) kg 4.25 4.25 5.5 5.5 5.65
Height H mm 31 31 41 41 41
DIMENSIONS - FLANGE . . . .
Flange diameter D mm 148 148 163 163 163
Hole circle diameter K mm 110 110 125 125 125
Number of screwholes pcs 4 4 4 4 4
Screwhole diameter D1 mm 18 18 18 18 18
Height H mm 69 69 73.5 73.5 73.5
Height H1 mm 87 87 90 90 90
Width F mm 138 138 147 147 147
Weight with flanges (approx.) kg 6.67 6.67 7.23 7.23 7.47

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph Typical error graph

Diehl Metering S.A.S. ∙ Head Office ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 00 ∙ Fax: + 33 (0)3 89 69 72 20 ∙ metering-France-info@diehl.com ∙ www.diehl.com/metering
International Sales ∙ 67 rue du Rhône ∙ BP 10160 ∙ FR-68304 Saint-Louis Cedex ∙ Phone: + 33 (0)3 89 69 54 21 ∙ Fax: + 33 (0)3 89 69 54 22 ∙ metering-France-export@diehl.com
Subject to technical adjustments.

11.03.2020 · 7