E14R00P54
Dual Band Tower Mounted Amplifier, 1800//2100 MHz, 12 dB, 2 BTS &
2 ANT ports, with 4.3-10 connectors, AISG with 1 RET connector (1 device
with 2 sub-units each)
Industry leading PIM performance
Single AISG with 1 RET connector
2 input ports and 2 output ports
Designed to boost UP-Link Coverage and KPIs
New 4.3-10 connectors for improved PIM performance and size reduction
1 device with 2 sub-units
Product Classification
Product Type 2-BTS:2-ANT (Uniplex) | Tower mounted amplifier
General Specifications
Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
Dimensions
Height 280 mm | 11.024 in
Width 175 mm | 6.89 in
Depth 98 mm | 3.858 in
Mounting Pipe Diameter Range 42.6–122 mm
Outline Drawing
Page 1 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14R00P54
Electrical Specifications
License Band, LNA DCS 1800 | IMT 2100
Electrical Specifications, dc Power/Alarm
dc Switching/Redundancy Yes
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Voltage 7–30 Vdc
Electrical Specifications, AISG
AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9
AISG 2.0 Page 2 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14R00P54
Protocol AISG 2.0
Voltage, AISG Mode 10–30 Vdc
Electrical Specifications
Sub-module 1|2 1|2
Branch 1 1
Port Designation ANT ANT
License Band DCS 1800, LNA IMT 2100, LNA
Return Loss, typical, dB 20 20
Return Loss - Bypass Mode, typical, dB 16 16
Electrical Specifications Rx (Uplink)
Frequency Range, MHz 1710–1785 1920–1980
Bandwidth, MHz 75 60
Gain, nominal, dB 12 12
Noise Figure, typical, dB 1.7 1.6
Total Group Delay, typical, ns 120 80
Insertion Loss - Bypass Mode, typical, dB 2.5 2.3
Electrical Specifications Tx (Downlink)
Frequency Range, MHz 1805–1880 2110–2170
Bandwidth, MHz 75 60
Insertion Loss, typical, dB 0.5 0.3
Total Group Delay, typical, ns 25 15
Return Loss, typical, dB 20 20
Input Power, RMS, maximum, W 200 200
Input Power, PEP, maximum, W 1000 1000
3rd Order PIM, typical, dBc -160 -162
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers
Block Diagram
Page 3 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14R00P54
Environmental Specifications
Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Corrosion Test Method IEC 60068-2-11, 30 days
Environmental Test Method ETSI EN 300 019-1-4
Ingress Protection Test Method IEC 60529:2001, IP67
Packaging and Weights
Included Mounting hardware
Volume 4.8 L
Weight, net 6.5 kg | 14.33 lb
Weight, without mounting hardware 6 kg | 13.228 lb
* Footnotes
License Band, LNA License Bands that have RxUplink amplification
Page 4 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023