Model 65023

Sensortronics

Shear Beam Load Cell


FEATURES
• Rated capacities of 250 to 20,000 pounds, 125 to
65059-TWA
10,000 kg
• “Thru” or “threaded” load hole configurations
• Low sensitivity to axial loads
• Low profile (ultra low available in 1000 to 2500 pound
ranges)
• Sensorgage™ sealed to IP67 standards 65082-TWA
• Factory Mutual System Approved for Classes I, II, III;
Divisions 1 and 2; Groups A through G. Also, non-
incendive ratings (No barriers!).
• Trade certified for NTEP Class III: 5000d, IIIL: 10000d
and OIML R-60 3000d available
• Optional
❍❍ Ex ia IIC T4, Ex ia IIIC T135°C hazardous area

approval
❍❍ Stainless steel versions available It has high immunity to shock or side loading and is
❍❍ 65059 TWA companion weighing assemblies available available in 2 or 3 mV/V sensitivity. Approved to OIML,
NTEP standards. For hazardous environments this load
APPLICATIONS cell is available with EEx ia IIC T6 level of European
approval.
• Floor scales
Nickel plating and full environmental sealing assures long-
• Tank weighing term reliability. A stainless steel option is available for the
• Bin and hopper weighing lb versions for use in harsh or corrosive environments.
The two additional sense wires feed back the voltage
DESCRIPTION reaching the load cell. Complete compensation of
Model 65023 is a low profile shear beam load cell changes in lead resistance due to temperature change
designed for high accuracy platform scales, pallet scales and/or cable extension is achieved by feeding this voltage
and process weighing applications. into the appropriate electronics.

OUTLINE DIMENSIONS in inches [millimeters]

Wiring
+ Excitation Red
– Excitation Black
+ Output Green
– Output White

CAPACITY A1 A2 B C D E F G H DEFLECTION WEIGHT


250–500 lbs 1.00 1.25 5.12 0.62 1.00 3.00 2.25 0.53 1/2-20 UNF-2B, Ø0.53 x 0.50 DP C’BORE 0.013 1.7
1–4k 1.25 1.25 5.12 0.62 1.00 3.00 2.25 0.53 1/2-20 UNF-2B, Ø0.53 x 0.62 DP C’BORE 0.017–0.025 4.0
5k–10k 1.50 1.50 6.75 0.75 1.50 3.75 3.00 0.78 3/4-16 UNF-2B, Ø0.78 x 0.75 DP C’BORE 0.025–0.035 6.5
15k–20k 2.00 2.00 8.88 1.00 2.00 4.88 4.00 1.03 1”-14 UNF-2B, Ø1.03 x 1.00 DP C’BORE 0.048–0.063 9.0
[125–250 kg] [25.0] [31.0] [130.0] [16.0] [25.0] [76.0] [57.0] [13.0] M12 x 1.75-6H, Ø13 x 15 DP C’BORE [0.33] [0.8]
[500 kg–2 t] [32.0] [32.0] [130.0] [16.0] [25.0] [76.0] [57.0] [13.0] M12 x 1.75-6H, Ø13 x 15 DP C’BORE [0.432–0.635] [1.8]
[3 t–5 t] [38.0] [38.0] [171.0] [19.0] [38.0] [95.0] [76.0] [20.7] M20 x 2.5-6H, Ø20.5 x 19 DP C’BORE [0.635–0.889] [2.9]
[10 t] [51.0] [51.0] [226.0] [25.0] [51.0] [124.0] [102.0] [25.0] M24 x 2-6H, Ø25.4 x 25 DP C’BORE [1.219–1.600] [4.1]
Capacities are in pounds [kg/t]. Deflection is ±10%. Certified drawings are available.

Document No.: 11575 Technical contact: vpgt.americas@vpgsensors.com, www.vpgtransducers.com


Revision: 21-Apr-2016 vpgt.asia@vpgsensors.com, and vpgt.emea@vpgsensors.com 1
Model 65023
Sensortronics

Shear Beam Load Cell

SPECIFICATIONS
PARAMETER VALUE UNIT
250, 500, 1k, 1.5k, 2k, 2.5k, 4k, 5k, 10k, 15k, 20k lbs
Rated capacity—R.C. (Emax)
125, 250, 500, 750, 1000, 2000, 5000, 10,000 (1) kg
NTEP/OIML accuracy class NTEP III NTEP IIIL Standard OIML R60
Maximum no. of intervals (n) 3000 single 10000 multiple 3000 (1)
Y = Emax/Vmin NTEP Cert. No. 86-044A2 6250 Maximum available
Rated output—R.O. 3.0 mV/V
Rated output tolerance 0.25 ±% mV/V
Zero balance 1.0 ±% FSO
Combined error 0.02 0.02 0.03 0.02 ±% FSO
Non-repeatability 0.01 ±% FSO
Creep error (30 minutes) 0.025 0.03 0.03 0.017 ±% FSO
Temperature effect on zero 0.0010 0.0010 0.0015 0.0010 ±% FSO/°F
Temperature effect on output 0.0008 0.0008 0.0008 0.0007 ±% of load/°F
Compensated temperature range 14 to 104 (–10 to 40) °F (°C)
Operating temperature range 0 to 150 (–18 to 65) °F (°C)
Storage temperature range –60 to 185 (–50 to 85) °F (°C)
Sideload rejection ratio 500:1
Safe sideload 100 % of R.C.
Maximum safe central overload 150 % of R.C.
Ultimate central overload 300 % of R.C.
Excitation, recommended 10 VDC or VAC RMS
Excitation, maximum 15 VDC or VAC RMS
Input impedance 343–357 Ω
Output impedance 349–355 Ω
Insulation resistance at 50 VDC >1000 MΩ
Material Nickel-plated alloy tool steel (2)
Environmental protection IP67
All capacities up to 5000 kg–136.0
Recommended torque N*m
5000 kg–205.0
Notes
(1)
OIML approval 1k–10k lbs and 500–5000 kg only
(2)
Stainless steel available
FSO—Full Scale Output
All specifications subject to change without notice.

www.vpgtransducers.com Technical contact: vpgt.americas@vpgsensors.com, Document No.: 11575


2 vpgt.asia@vpgsensors.com, and vpgt.emea@vpgsensors.com Revision: 21-Apr-2016
Legal Disclaimer Notice
Vishay Precision Group, Inc.

Disclaimer
ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “VPG”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in
any other disclosure relating to any product.

The product specifications do not expand or otherwise modify VPG’s terms and conditions of purchase, including but
not limited to, the warranty expressed therein.

VPG makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase.
To the maximum extent permitted by applicable law, VPG disclaims (i) any and all liability arising out of the
application or use of any product, (ii) any and all liability, including without limitation special, consequential or
incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.

Information provided in datasheets and/or specifications may vary from actual results in different applications and
performance may vary over time. Statements regarding the suitability of products for certain types of applications
are based on VPG’s knowledge of typical requirements that are often placed on VPG products. It is the customer’s
responsibility to validate that a particular product with the properties described in the product specification is suitable for
use in a particular application. You should ensure you have the current version of the relevant information by contacting
VPG prior to performing installation or use of the product, such as on our website at vpgsensors.com.

No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any
conduct of VPG.

The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise
expressly indicated. Customers using or selling VPG products not expressly indicated for use in such applications do
so entirely at their own risk and agree to fully indemnify VPG for any damages arising or resulting from such use or sale.
Please contact authorized VPG personnel to obtain written terms and conditions regarding products designed for such
applications.

Product names and markings noted herein may be trademarks of their respective owners.

Copyright Vishay Precision Group, Inc., 2014. All rights reserved.

Document No.: 63999 www.vpgsensors.com


Revision: 15-Jul-2014 1