Lever Sensor
Lever Sensor
E2K-L
• Installation on pipes.
• Sensing by means electrostatic capacity and is not
influenced by the color of the pipe or liquid.
• Available in 8 to 11 mm dia. and 12 to 26 mm dia.
models to enable sensing for a wide range of pipe
diameters.
• Built-in amplifier for space-saving.
Applications
Liquid surface level detection
E2K-L
Ordering Information
Sensor type Applicable pipe diameters Shape Output form Model
8 to 11 mm dia. E2K-L13MC1
12 to 26 mm dia. E2K-L26MC1
E2K-L D-203
Rating/Performance
Item Model E2K-L13MC1 E2K-L26MC1
Material Non-metal
External
8 to 11 mm dia. 12 to 26 mm dia.
Applicable pipes diameter
Size
Wall
1 mm max. 1.5 mm max.
thickness
Sensing object Liquid (see note)
Repetition precision ±0.2 mm max.
Response difference
(reference value only; varies 0.6 to 5 mm 0.3 to 3 mm
with pipe size and solution)
Supply voltage
12 to 24 VDC, 10% max. ripple (10.8 to 30 VDC)
(operating voltage range)
Current consumption 12 mA max.
Switching
100 mA max.
capacity
Control output
Residual
1 V max. (under load current of 100 mA with cable length of 2 m)
voltage
Detection position of liquid surface Notch position (For details, refer to Sensitivity Adjustment on next page.)
Indicator lamp Operation indicator (orange)
Ambient temperature Operating: 0 to 55°C; Storage: -10 to 65°C (with no icing or condensation)
Ambient humidity Operating/storage: 25% to 85% (with no condensation)
In the range 0 to 55°C: Detection level at 23°C 4 mm (with distilled water or 20 % salt water con-
Temperature influence centration)
(±6 mm with E2K-L13MC1 for distilled water in pipe of 8 mm diameter)
Voltage influence At the rated power supply voltage ±10%: Detection level at rated supply voltage ±0.5 mm
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 500 m/s2 for 3 times each in X, Y, and Z directions
Protective structure IEC 60529 IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 70 g
Case, cover Heat-resistant ABS resin
Material
Cable clamp NBR
Accessories 2 binding bands, 4 nonskid tubes, instruction manual
Note: In the following cases, stable detection may not be possible and ensure to confirm correct operation in the actual installation before use.
1 . If the dielectric constant or conductivity of the liquid is low.
2 . If the capacity of the liquid is small, or if the pipe diameter is so small or the pipe walls are so thick that the amount by which the capacity changes relating to
the liquid level is small.
3 . In case of an increased gassing or a highly viscous liquid firm residue on the inside walls of the pipe, or a dirt clogging on the inner or outer walls of the pipe.
6 6
2 2
10 20 0 10
0 0
-10 0 30 40 50 60 -10 20 30 40 50 60
Temperature (C˚) Temperature (C˚)
-2 -2
-4 -4
-6 -6
Brown
+V
Yes
Liquid surface Load
No
Main Black *
E2K-L13MC1 Load Operates
NO E2K-L26MC1 (brown-black)
circuit
Releases
Operation indicator ON
Blue
(orange) OFF 0V
Operation
E2K-L
Sensitivity adjustment
1. Install the Sensor with the setting position (notch) in line 2. After Sensor installation adjust the detecting sensitivity using
with the liquid level to be detected. the (12-step) sensitivity adjuster in the way shown below.
Status of the
Pipe
indicator when
the liquid level Sensitvity adjuster Adjustment procedure
is aligned with
Sensor the setting position
1
Turn the sensitivity adjuster
Not lit clockwise using a screwdriver
Level of until the indicator lights.
liquid surface
E2K-L D-205
Precautions
Correct Use
Design Installation
Influence of Surrounding Objects Sensor installation
Performance may be adversely affected by conductive ob- Attach the Sensor securely to the pipe using the 2 binding
jects (e.g., metals) in the vicinity of the Sensor. Ensure that bands and the 4 nonskid tubes provided (2 tubes per band) in
any conductive objects are separated from the Sensor and the way shown below.
set at a minimum distance as shown below. Install the Sensor in such manner that the pipe is in contact
with the entire sensing face of the Sensor with the pipe and
Pipe Sensor
Sensor in parallel.
Pipe
Sensitivity
Sensor Operation indicator adjuster
A
Object on Opposite Side Level of
liquid surface
Setting position
B
(notch)
C Binding bands
Slip-prevention tubes
Pipe Sensor
Object on One Side Objects on Both Sides
D ● Operating Environment
Ambient Conditions
• Although this product has waterproof specifications, do not
F
use it in locations where it may have a direct contact with
E liquids (e.g., water or cutting oil). Such locations can interfere
Installed in Installed in Parallel Installed in Facing with the electrostatic capacity method used by the Sensor.
Series Sides Each Other
• Even if the Sensor is used within the specified temperature
Mutual Interference (Unit: mm) range, do not subject it to sudden changes in temperature
Shape Length D (see note) E F
because this will shorten the service life.
E2K-L13MC1 25
10 10
E2K-L26MC1 30 Miscellaneous
* The detection level for the top Sensor may change when the detection level Drift may occur when the power supply is turned ON. If the di-
for the bottom Sensor is set. Be sure to set the detection level for the bottom
Sensor first.
electric constant of the liquid is low, the detection level of the
liquid may be 2 to 3 mm higher than the set level for approxi-
mately 20 minutes after power is turned ON.
E2K-L13MC1
20
5
R6.5 R17.5
24
Mounting holes
11 1.5
6
43 41 33
4 5 4.5
1
Sensitivity adjuster
Sensing surface
3.5
6
6.5
2.9-dia. three conductors vinyl-insulated round cable
(cross-sectional area of conductors: 0.14 mm2;
insulation diameter: 0.9 mm) Standard length: 2 m
E2K-L26MC1
20
E2K-L
R13 R17.5
33 Mounting holes
Operation indicator 6 4.5
11 1.5 (orange) Sensitivity adjuster
2
34 32 24
3
Sensing surface
3.5
6.5 6
E2K-L D-207
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D094-E2-01-X In the interest of product improvement, specifications are subject to change without notice.