LOCATION LIST

H158
BILL OF MATERIALS ASSEMBLY MK'D : AB1144 ASSY QTY : 1 GENERAL NOTES :
MARK NO. GRID LOCATION
H160
SF130 SF130 AB1144 5004-ST001I/1-5004-ST001I/2/5004-ST001I/A +105.100 Item Qty./ Profile Size Wt./Meter Length Wt./Item Total Total Wt. Material 1. ALL DIMENSION ARE IN MILLIMETERS AND LEVELS ARE IN METRES.
SF129 SF129 Mark Assembly Qty. 2. DRAWING SHALL NOT BE SCALED AND ONLY DIMENSIONS SPECIFED SHALL BE FOLLWED.
AB1144 1 HEA450 140.00 5496 770.00 1 770.00 S275JR
3. INDICATES SHOP MARK & SHALL BE PROVIDED/ HARD PUNCHED BY THE FABRICATOR ON
6 3 SIDES TYP EP113 1 PL12*300 94.20 428 12.10 1 12.10 S275JR
6 3 SIDES TYP FLANGE OF MEMBER/FACE OF PLATES ON EACH ASSEMBLY AS SHOWN ON EACH ASSEMBLY
6
6 H154 2 HEA200 42.30 400 16.62 2 33.23 S275JR
AS SHOWN ON SHOP DETAIL DRAWINGS. SAME IS TO BE REFERRED FOR ORIENTATION
TYP H158 1 HEA240 60.30 850 51.50 1 51.50 S275JR
DURING ERECTION OF THE ASSEMBLY.
6 TYP H159 2 HEA240 60.30 360 21.24 2 42.47 S275JR 4. MASKING INDICATED ON MEMBERS/PARTS SHALL BE APPLIED WITH PRIMER COAT ONLY.
6 H159 H160 1 HEA200 42.30 1050 44.58 1 44.58 S275JR
5. INDICATES MASKING SURFACE/CONNECTING SIDE TO BE MASK AS PER DETAIL GIVEN.
H154 6
14
110 AB1144 110 HP101 2 PL25*300 196.25 822 48.41 2 96.82 S275JR 6. WHERVER MENTIONED 'MASKING BOTH FACE', 'MASKING THIS FACE' SHALL BE MASKED BEFORE
6 AB1144
14 HP102 2 PL10*399 78.50 690 11.45 2 22.91 S275JR
SF108 AB1144 APPLYING PRIMER IN ORDER TO ALLOW FRICTION BETWEEN BOLTED SURFACES FOR HSFG BOLTS.
TYP 6 MP101 2 PL30*300 235.50 1120 79.13 2 158.26 S275JR
110 7. THIS MEMBER'S ASSEMBLY MARK SHALL BE PREFIXED WITH ITEM TAG AS -

60
6 SF108 3 PL20*139 157.00 397 8.63 3 25.89 S275JR

60
SF108
AB1144 AB1144 AND HARD PUNCHED NEAR
SF123 1 PL20*144 157.00 397 8.94 1 8.94 S275JR '5004ST001I'.
14 SF126 3 PL10*144 78.50 397 4.47 3 13.41 S275JR

55
60

TYP 8. ALL WELDS SHALL HAVE A MINIMUM LEG EQUAL TO 0,7 X (MINIMUM THICKNESS TO BE CONNECTED)

55
SF131 SF123 14 SF128 4 PL10*139 78.50 200 2.17 4 8.69 S275JR
9. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS.
6 TYP 10 SF108 SF129 4 PL10*92 78.50 169 1.21 4 4.82 S275JR
10. SEAL ALL WELDS. SEAL WELD IN STRUCTURAL CONNECTIONS SHALL BE CONTINUOUS.
55

SF128 6 10 10 TYP SF130 4 PL10*111 78.50 205 1.78 4 7.10 S275JR


SF126 10
10 TYP SF131 2 PL10*139 78.50 397 4.31 2 8.63 S275JR
SF126 14 10
SF128 14 SF177 1 PL10*144 78.50 397 4.47 1 4.47 S275JR
6 3 SIDES TYP 3 SIDES TYP 8 14
6 14 TYP TYP Total 1313.83
8 14
8 14 ASSEMBLY MARK UNIT QTY. LENGTH
3 SIDES TYP Field Bolts
8
A-A C-C F-F AB1144 24 M27.0Ø A325M(8.8) 90

E-E B-B

2708
2588

5496
2588 120 2788
0

H158 SF128 SF177 SF129


SF128 SF131
EP113 H154 SF131 SF108
SF108 SF130 H159 SF130 SF129
AB1144 HP101
75 75

75 75
HP102 HP102

HP101
MP101 SF130 SF130 H160 H154 SF129
SF123 SF126 SF126 SF108 MP101
SF128 SF128 SF129 SF126
H159
THIS DOCUMENT IS TECNIMONT'S/SONATRACH'S PROPERTY AND CANNOT BE USED BY OTHERS FOR ANY PURPOSE, WITHOUT PRIOR WRITTEN CONSENT

5556 (HEA450 x 5496)

30 5496 30

3388

5496
748

748 2640 2108


0

1448

3538

4288

5496
898

898 550 2090 750 1208


0

145 550 155 145 750 155


SF130 BS
SF130 BS A B H158 B SF129 BS E H160 E
SF129 BS
CTR'D CTR'D

190
230

140
CTR'D

CTR'D

CTR'D

CTR'D
140
H159

H159

H154

H154
400
360

MP101 9
C
TYP D
9 SF123 F
60

60
SF177 SF108 BS
SF108 SF126 00 29.11.2023 ISSUED FOR CONSTRUCTION AST VKS GS
AB1144
80

80
280

280
TYP 8
8 sonatrach

Realisation en EPC d'une usine d'extraction de GPL a Rhourde el Baguel


140

140
SF128 BS EP113 SF131 SF126 CT-EPC/008/SH/EPM-E&P-G/2022
CJP C SF126 SF131 E
TYP SF128 BS B D E
TYP 14 F
260

260
14 HP102 A

TYP
411
B
CTR'D HP102
CTR'D
8 TYP
8
HP101
CTR'D
ASSEMBLY DRAWING
180

180
HP101 FEED COMPRESSOR PROCESS STRUCTURE 5004-ST001I-A
CTR'D
712 FABRICATION DETAILS OF BEAM
CJP TYP
TYP
MP101
5004ST001I03AB1144
738 155 550 130 1070 890 10 740 451 762
4191-AI-VD-AS0015004ST001
0

738

893

1443

1573

2643

3533
3543

4283

4734

5496
A1 1/1

150 12 EPC008-GREB-DD-S-90SA500401-E 1:10 00


SF177 92 6 TYP Purchase Order No. 7500113527 Material Req.No.
4191-AI-MR-001
AB1144 6
SHOP NOTE :
INDICATES NO FIREPROOFING ALL ROUND TO THIS ASSEMBLY IS PARTIALLY FIREPROOF WITH Vendor Doc No.
4191-AI-VD-AS0015004ST001I0144-03AB1144
64 6

BE DONE AT SHOP. ONLY PRIMER TO BE APPLIED. TOP FLANGE EXPOSED. TOP OF BEAM SHALL BE FULLY PAINTED.
MASKING APPLICABLE AT PAINTED AREA PER NOTE 5.
60 70

VENDOR NAME :
1 BEAM REQUIRED AS DRAWN MARKED 5004ST001I03AB1144[FP3] SISCOL
290

25 min. 25 min.
STEEL INFRA SOLUTIONS PRT. LTD.
25 min. 25 min. 25 min. 25 min.
TYPE-I TYPE-II TYPE-III TYPE-IV Mezzanine Floor,
60

25 min.

CASE - 1 CASE - 3
25 min.

CASE - 2
25 min.

( BOLT C/C >100) DOUBLE BEVEL BUTT WELD DOUBLE V BUTT WELD SINGLE BEVEL WELD SINGLE BEVEL BUTT WELD 'Gayatri Lakefront 'Sy.No.118,
SEAL 3 WITH BACKING STRIP Ring Road, Hebbal ,
EP113 WELD 3 45 Bengaluru 560024.
(TYP °
25 min.

MASKING AREA www.siscol.in


25 min.

.)
25 min.

6 MASKING AREA MASKING AREA


60° 60°
3

6
3
3

3
T>16

3
3 SIDES T
T>16

6
3

T<12
3

45° .)
DETAILS FOR MASKING AREA

3
P
D-D TYP SEAL WELD DETAIL
(TY
==
3
3
ALL CONNECTION AREAS SHALL BE MASKED BACKING PLATE
==
IN ORDER TO ALLOW ELECTRICAL CONDUCTIVITY
2
10X6 FLAT MODEL NAME : 4191-AIVD-3D-5004-ST001I-A
(ONLY ZINC PRIMERS TO BE APPLIED FOR MASK AREA)