SERIES 65

Conventional Fire Detectors and Series 60


Intrinsically Safe Detectors

The Series 65 range of fire detectors comprises ionisation and optical smoke
detectors and four grades of heat detector, all with enhanced performance,
high reliability and attractive appearance. Each detector incorporates an
application-specific chip, using technology originally developed for analogue
addressable detectors.

Benefits An integrating ionisation detector,


• Wide voltage range of 9-33V suitable for use in areas where
• World wide approvals transient high levels of smoke may be
• ASICS for increased reliability expected is also available.
• Polarity insensitive Item Part No.
• High environmental performance Integrating Ionisation Smoke Detector
• Ease of installation 23900-K032-065
• Positive, one-way fit base
• Attractive design Series 65 Optical Smoke Detector
• Identical in appearance to Series 60 Optical smoke detectors incorporate a
pulsing LED located in a labyrinth
Series 65 Ionisation Smoke Detector within the housing of the detector. The
The sensing part of the detector labyrinth is designed to exclude light
consists of two chambers – an open, from any external source. At an angle
outer chamber containing a semi- to the LED is a photo-diode which
sealed reference chamber. normally does not register the column
of light emitted by the LED.
As smoke enters the detector, it causes
a reduction of the current flow in the In the event of smoke from a fire
outer chamber and hence an increase entering the labyrinth the light pulse
in the voltage measured at the from the LED will be scattered and
junction between the two chambers. hence registered by the photo-diode. If
The voltage increase is monitored by the photo-diode "sees" smoke on the
the electronic circuitry which triggers two following pulses, the detector
the detector into the alarm state at a changes to the alarm state. The
preset threshold. An externally visible indicator LED which is clear in
LED will light up when the detector quiescent state, changes to red light in
changes to alarm state. alarm.
Item Part No. Item Part No.
Ionisation Smoke Detector 23900-KO31-065 Optical Smoke Detector 23900-K034-065
SERIES 65
2
Conventional Fire Detectors and Series 60 Intrinsically Safe Detectors

Series 65 Heat Detector Series 60 Intrinsically Safe Detector Ancillary Items


The A1R, BR & CR (rate of rise) heat The Series 60 Intrinsically Safe Detector The air sampling unit allows the Series
detectors are resettable and operate range incorporates all the benefits of 65 Detector to be used to monitor
by using a matched pair of thermistors the standard range, but has been ventilation ducts. The Air Sampling
to sense heat. One thermistor is developed specifically for use in Unit must be used in conjunction with
exposed to the ambient temperature, hazardous areas. The detectors must a Duct Sampling Tube.
the other is sealed. In normal be used in a system which includes Item Part No.
conditions the two thermistors register suitable safety barriers. 762mm Sample Tube 23900-K168
similar temperature. On the Item Part No. 1524mm Sample Tube 23900-K169
development of a fire, the IS Ionisation 23900-K076 3048mm Sample Tube 23900-K170
temperature recorded by the exposed IS Integrating Ionisation 23900-K077 Air Sampling Unit including standard base
thermistor will increase rapidly, IS Heat Detector Grade 1 23900-K078 23902-H11
resulting in an imbalance of the IS Heat Detector Grade 2 23900-K079
thermistors and causing the detector IS Heat Detector Grade 3 23900-K051 The remote indicator unit allows
to change to the alarm state. IS Heat Detector Range 1 23900-K080 repeat indication of the alarm LED on
IS Heat Detector Range 2 23900-K081 a detector in a hidden location, eg
Rate of rise detectors are designed to IS Detector Base 23900-K052 ceiling void.
detect a fire as the temperature Item Part No.
increases. They also have a fixed upper Series 65 Bases Remote Indicator 23900-K095
limit at which the detector will go into The base is designed to enable
alarm if the rate of temperature detectors to be plugged in without Series 65 smoke and heat detectors
increase has been too slow to trigger need for force. This is particularly comply with EN54 (BS5445), which is
the detector earlier. useful when fitting to suspended the European standard for fire
ceilings. The base also incorporates a protection system components. The
The CS (static response) heat detector "one way only" fit. All Series 65 bases range holds approvals worldwide,
has only one thermistor and changes are lockable. The detectors are polarity including LPC in the UK and VdS in
to the alarm state at a preset insensitive and bases are easy to wire Germany.
temperature. with an earth connector. The standard
base contains no electronic parts which
Item Part No. could be damaged during installation.
A1R (57°C) 23900-K035-065 Item Part No.
BR (75°C) 23900-K036-065 Standard Series 65 Base 23902-H08
CR (90°C) 23900-K038-065
CS (90°C) 23900-KO39-065 For conventional systems that are
designed to operate correctly when
one or more detector heads have been
removed, a base fitted with a diode on
Line 1 is available.
Item Part No.
Diode Base 23902-H09

The relay base allows operation of


auxiliary item(s) via a relay contact in
the detector base which operates for
the individual detector alarm
condition.
Item Part No.
Relay Base 23902-H10
SERIES 65
3
Conventional Fire Detectors and Series 60 Intrinsically Safe Detectors

Specification

Typical at 23°C and Ionisation Ionisation Optical A1R BR CR CS


24 VDC unless (Std) (Integrating) 57°C 75°C 90°C 90°C
otherwise stated
Detector Part No. 23900-K031-065 23900-K032-065 23900-K034-065 23900-K035-065 23900-K036-065 23900-K038-065 23900-K039-065
Base Part No. 23902-H08 23902-H08 23902-H08 23902-H08 23902-H08 23902-H08 23902-H08
Size of Detector
(Height x Diameter (mm)) 42x100 42x100 42x100 42x100 42x100 42x100 42x100
Size of Detector in Base
(Height x Diameter (mm)) 50x100 50x100 50x100 50x100 50x100 50x100 50x100
Supply Voltage 9-33VDC 9-33VDC 9-33VDC 9-33VDC 9-33VDC 9-33VDC 9-33VDC
Average Quiescent
current at 24V 28µA 45µA 40µA 45µA 55µA 55µA 55µA
Alarm Current at 24V 52mA 52mA 52mA 52mA 52mA 52mA 52mA
Alarm Indication Red LED Red LED Clear LED Red LED Red LED Red LED Red LED
red in Alarm
Normal Operating -20°C to -20°C to -20°C to -20°C to -20°C to -20°C to -20°C to
Temperature (no icing) +60°C +60°C +60°C +90°C +90°C +90°C +90°C
Humidity
(no condensation) 0-95% 0-95% 0-95% 0-95% 0-95% 0-95% 0-95%
Max wind (continuous) 10m/s 10m/s not affected not affected not affected not affected not affected
Remote Output
Characteristics 900 Ohm in series with a 3V drop (suitable for connecting one LED)

Kidde Fire Protection operates a continuous programme of product development. The right is therefore reserved to modify any
specification without prior notice and Kidde Fire Protection should be contacted to ensure that the current issues of all technical
data sheets are used.
FM 00215

Kidde Fire Protection


Thame Park Road, Thame, Oxfordshire OX9 3RT
© Kidde Fire Protection Tel: +44 (0)1844 265003. Fax: +44 (0)1844 265156. E-mail: general.enquiries@kiddeuk.co.uk
6357/1 07.06 Web: www.kfp.co.uk