PMPW™ - 10 HOLLOW FIBER CARTRIDGE
10-inch Potable Water Ultrafiltration Cartridge
PRODUCT              Membrane Chemistry:                                 Proprietary semi-permeable polysulfone
DESCRIPTION          Housing Shell/End Caps:                             PVC
                     Fiber Support Netting:                              Polypropylene/Polyethylene
                     Permeate Collection Tube:                           PVC
                     Potting Material:                                   Proprietary epoxy compound
                     Nominal Molecular Weight Cut-off:                   100,000 Daltons
                     Membrane Construction:                              Hollow fiber
                     Preservative:                                       Glycerin
PRODUCT                    Model                      Part Number               Production Range gpm (m3/hr)
                     HF 10-72-35-PMPW                   0720701                    24.2 – 51.4 (5.5 – 11.6)
SPECIFICATIONS       HF 10-48-35-PMPW                   0720700                    15.4 – 32.7 (3.5 – 7.4)
OPERATING &          Maximum Inlet Pressure (water):                     45 psi @ 104° F (3.0 bar @ 40° C)
                     Temperature Range:                                  33 - 104° F (0 - 40° C)
DESIGN               Maximum Production Transmembrane Pressure:          35 psi (2.4 bar)
INFORMATION          Maximum Backflush Transmembrane Pressure:           20 psi (1.4 bar)
                     Allowable pH Range:                                 1.5 - 13
                     Maximum Total Chlorine @ 77° F (25° C) or lower:    200 ppm @ 9.5 pH or higher during intermittent backflush
                     Maximum Total Chlorine Contact:                     200,000 ppm-hrs cumulative
PRODUCT                                                                                         D                L
                           Model                Fiber Diameter (ID)     Membrane Area         Inches (mm)      Inches (mm)
DIMENSIONS           HF 10-72-35-PMPW           0.035 inch (0.9 mm)     871 ft2 (80.9 m2)      10.75 (273)       72 (1829)
                     HF 10-48-35-PMPW           0.035 inch (0.9 mm)     554 ft2 (51.5 m2)      10.75 (273)       48 (1219)
                     “D”
                                                                          “L”
         PMPW™ - 10 HOLLOW FIBER CARTRIDGE
         Cartridge Storage Conditions:                                                                       •      Add caustic (NaOH) slowly to achieve a pH of 12.0
         New Cartridges                                                                                             (~ 0.5 wt% NaOH addition)
         New cartridges are impregnated with glycerin as a                                                   •      Circulate caustic solution through the system for 20 to 30
         preservative.    Glycerin should be removed from new                                                       minutes
         cartridges before initial use with a rinse followed by a caustic                                    •      Drain and completely flush system with clean water at a
         wash and then a caustic/chlorine wash.                                                                                                     o          o
                                                                                                                    water temperature between 50 F and 85 F (10 C and
                                                                                                                                                                      o
                                                                                                                    30o C)
         New cartridges should be kept in their original shipping
         containers and crates until ready for installation. Cartridges                                      Caustic/Chlorine Wash
         should be stored as follows:                                                                        •  Heat clean water (< 60 mg/liter CaCO3 hardness) to
                                                                                                                             o     o             o      o
                                                                                                                between 85 F (30 C) and 110 F (45 C)
         •      Store the cartridges indoors and out of direct sunlight.
                                                                                                             •  Circulate heated water through the system under
         •      Store the cartridges at temperatures between 50 – 85o F
                                                                                                                standard pressure and flow conditions
                (10 – 30o C).
                                                                                                             •  Add caustic (NaOH) slowly to achieve a pH of 12.0
         •      Store the cartridges at relative humidity below 70%.
                                                                                                                (~ 0.5 wt% NaOH addition)
         •      Store the cartridges in a horizontal position.
                                                                                                             •  Add liquid sodium hypochlorite (NaOCl) to achieve a
         Used Cartridges                                                                                        total chlorine concentration of 200-mg/liter total chlorine
         Used cartridges should be cleaned, rinsed and impregnated                                              (max.)
         before storage with one of the following preservative                                               •  Circulate caustic/chlorine solution for 20 to 30 minutes.
         solutions.                                                                                          •  Check caustic/chlorine solution and add NaOCl as
                                                                                                                required to maintain total chlorine concentration
         •      Glycerin @ 80 – 100% (best)                                                                  •  Drain and completely flush system with clean water at a
         •      Phosphoric acid @ pH 2 – 3                                                                      water temperature between 50o F and 85o F (10o C and
         •      Benzoic acid or sodium benzoate @ 1,000 ppm                                                         o
                                                                                                                30 C)
         •      Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000
                                                                                                             Acid Wash
                ppm
                                                                                                             •   Heat clean water (< 60 mg/liter CaCO3 hardness) to
         Cartridge preserved with sodium bisulfite or sodium                                                     between 85o F (30o C) and 110o F (45o C)
         metabisulfite should be flushed with clean water and                                                •   Circulate heated water through the system under
         impregnated with fresh solution at six-month intervals. Once                                            standard pressure and flow conditions
         impregnated the cartridges should be left on the system with                                        •   Add citric acid (solid) slowly to achieve a pH of 2.5 (~ 0.5
         all valves closed or removed from the system and sealed in                                              wt% citric acid addition)
         plastic bags. Storage conditions described above for new                                            •   Circulate acid solution through the system for 20 to 30
         cartridges should be used for storage of used cartridges.                                               minutes
         Cartridges must be drained, rinsed and cleaned after storage                                        •   Drain and completely flush system with clean water at a
         using the caustic/chlorine wash procedure described below                                               water temperature between 50o F and 85o F (10o C and
                                                                                                                    o
         before reuse on the production system.                                                                  30 C)
         Cartridge Cleaning Procedures:                                                                      NOTE: ALWAYS ADD CAUSTIC BEFORE CHLORINE.
         General cartridge cleaning procedure before initial use of the                                      NEVER ADD CHLORINE TO A NEUTRAL OR ACID
         cartridges and as required to maintain satisfactory cartridge                                       SOLUTION.      ALL PROCESS LINES MUST BE
         productivity are outlined in this section.            Different                                     COMPLETELY FLUSHED BETWEEN EACH CAUSTIC,
         combinations of the following cleaning procedures, or custom-                                       CHLORINE, AND ACID WASH.
         cleaning procedures that may call for proprietary chemical
         formulations, may be required to achieve satisfactory cleaning                                      Contact Information:
         results.                                                                                            Technical Service Department: (978) - 694 - 7050
                                                                                                             Customer Service Department: (888) - 677 - 5624
         Caustic Wash
         •  Heat clean water (< 60 mg/liter CaCO3 hardness) to
                        o     o           o      o
            between 85 F (30 C) and 110 F (45 C)
         •  Circulate heated water through the system under standard
            pressure and flow conditions
         The information contained in this publication is believed to be accurate and reliable, but is not to be construed as implying any warranty or guarantee of performance. We assume no responsibility,
         obligation or liability for results obtained or damages incurred through the application of the information contained herein. Refer to Standard Terms and Conditions of Sale and Performance Warranty
         documentation for additional information.
                                                           Koch Membrane Systems, Inc., www.kochmembrane.com
       Corporate Headquarters: 850 Main Street, Wilmington, Massachusetts 01887-3388, USA, Tel. Toll Free: 1-888-677-5624, Telephone: 1-978-694-7000, Fax: 1-978-657-5208
European Headquarters: Koch Chemical Technology Group Ltd., The Granary, Telegraph Street, Stafford ST17 4AT, United Kingdom, Telephone: +44-178-527-2500, Fax: +44-178-522-3149
             • San Diego, California • Aachen & Dusseldorf, Germany • Lyon, France • Madrid, Spain • Milan, Italy • Wijnegem, Belgium • Beijing & Shanghai, China • Mumbai, India •
                                                                   • Melbourne, Australia • Singapore • Sao Paulo, Brazil •
                                                                           PMPW™ is a trademark of Koch Membrane Systems, Inc.
                                                                Koch Membrane Systems, Inc. is a Koch Chemical Technology Group, LLC company.
                                                                    © 2004 Koch Membrane Systems, Inc. All rights reserved worldwide. 02/07