SIGNAL TOWER

Model
L S 7- 9
IP69K RATED LED SIGNAL TOWER LIGHT

INSTRUCTION MANUAL
[ Maintenance Version ]
Installation Operation Maintenance

Page
1 Safety Precautions 2
2 Model Number
Configuration
3
3 Part Names and
Outer Appearance
3
4 Stackable Tower
Construction
4
5 Block Diagram 4
6 Installation 5-6
7 Wiring 7-9
8 Volume Adjustment 10
Notice to Customer
Thank you very much for purchasing PATLITE products.
9 Inspection 11
It is recommended that the installation and wiring be
performed by a professional contractor if construction
10 Troubleshooting 12
work is involved.
Prior to installation or using this product, please read
11 Specifications 13
this manual thoroughly to ensure correct use.
After reviewing this manual, if there are any questions 12 Replacement Parts 14
regarding this product, please contact the nearest
PATLITE office listed on the back cover of this manual. 13 Optional Parts 15
Notice to Contractor
Read this manual carefully prior to installation.
14 Dimensions for Mounting 15
Be sure to return this manual to the customer.
1 Safety Precautions
Safety Precautions

WARNING Failure to observe the following may result in death or serious injury.

To prevent short-circuits, electric It is recommended that the


shock or damage, observe the installation and wiring be performed
following: by a professional contractor if
construction work is involved.
. Be sure the signal light is Failure to comply may result in fire,
disconnected from the power electric shock or falling from high
supply before wiring or places.
performing repair work.
. Use the signal light in a properly Do not modify or disassemble the
signal light.
maintained condition.
(If parts such as the base or outer
cover are cracked, they should be
repaired.)

To ensure proper safety while using To ensure safety when the signal
OK ! the signal light, observe the light is installed onto equipment,
following: observe the following.
. Do not use the signal light as
. Perform periodic leverage when climbing up onto the
pre-maintenance. equipment. Failure to comply will
( “ 9 Inspection” (P.11)) result in falling from a high place, or
damage to the product.
. As a precaution, we suggest using . When performing tasks such as
this product with other back up opening the covers of the
safety equipment equipment, be careful not to snag
anything on the signal light. Failure
to observe may result in damage.

CAUTION If the following are not observed, injury to personnel or physical damage may result.

Use only the specified To protect the power supply and


replacement parts listed in this other internal circuitry, be sure to
manual. install an external fuse.

Avoid long exposure to the buzzer Do not disassemble or detach the


sound from a close distance. Failure unit while the unit is in operation.
to observe this may lead from
irritation to permanent damage to
the ears.
( B Buzzer included specifications)

Signal Light Application


This product is a multipurpose signal light, designed principally for giving notifications of the operating status for FA
(Factory Automation) equipment in factories, etc., using LEDs and buzzers .
B Buzzer included specifications only

Instruction Manual Objective


. The images in this manual may vary in comparison to the actual product and are only for the purpose of illustration.
. Store this manual for future reference.

2
2 Model Number Configuration
Model Number of Rated Body Flashing Buzzer Mounting Wiring Adaptor LED Color
LED Modules Voltage Color Color

Model Number LS7- 02 W -RYGBC

5
LED colors in order from top to bottom
5 LED Tiers (5 tiers) Red, Amber, Green, Blue and White
(3 tiers) Red, Amber and Green, blank (N),

3
blank (N)
3 LED Tiers

Common to all models Rated Voltage: 24 V DC


9N IP69K Adaptor,
Off-white

none Off-white C M12


Connector 9D IP69K Adaptor,
Black

H
Common to all * [ 9N ] for Off-white tower
D Dark Gray none Illumination Only none
Buzzer not
Included models
Lead Wires [ 9D ] for Silver tower
[ 9D ] for Dark Gray tower

S
Direct * [ F ] Illumination and
Silver F Illumination and
Flashing B Buzzer
Included Installation Only Flashing function is only
available for the [ H ]
lead wires specifications

Model Number LS7 - 5 0 2W C 9 N -R Y GB C LS7-502SFBWH9D-RYGBC


Example . Body color - Off-white . Buzzer - Not Included . Body color - Silver . Buzzer - Included
. Lighting - Illumination only . Input - M12 connector . Lighting - Illumination and flashing . Input - Lead wires

3 Part Names and Outer Appearance


Buzzer not included C M12 connector specifications B Buzzer included H Lead wires specifications

1 About the M12 Connector


. It is recommended to use the
optional connector with cable for
wiring. ( “ 13 Option Parts” (P.15))
(Note) It is not included for this
product (LS7).
. Because the M12 connector is inside
the signal light, be sure to allow a
sufficient length of cable.

1/2” NPT x 16
Socket Base
(p/n: SZI-130-IP69K)

(For B Buzzer included


specifications, the length is 89 mm.)

M12 Connector 1

Underside View Underside View

(Note) The Signal Light LED array is not replaceable. (Units: mm)

3
4 Stackable Tower Construction
What is a 'Stackable Structure'?
The ‘stackable structure’ is a feature which allows the main signal light
unit and the outer cover to be separated with just a single touch.
(Previous signal lights require tools to disassemble, such as removing
screws.)

The 'stackable structure' makes maintainance and inspection easier.

Never disassemble or remove any parts outside the


CAUTION
stackable parts.

Procedure for removing the stackable parts


Refer to the procedure below to remove the stackable parts.
To reinstall, follow the procedure in the reverse order.
The following example is for a model without a buzzer included.
The removal procedure is the same for the outer cover or the Optional Parts.( “ 13 Optional Parts” (P.15))

1 Unlock the base. 2 Remove the base.

Rotate

Hold the base and the 1/2” NPT socket base, and rotate until Pull the base in the upward direction to remove it.
the bar marks are aligned. Tip
. Do not twist the base too hard when removing it.
Tip
. The lock may be stiff.
. When reinstalling, fully rotate the base until the triangle mark
Tip For models equipped with a buzzer, the signal light is
and bar mark are aligned.
equipped with a buzzer case instead of a base.
WARNING: Incorrect installation of the 1/2” NPT Adaptor can result in the
loss of the IP69K rating.

5 Block Diagram
The following illustrates the internal block diagram for the signal light. Use it as reference when wiring.

LS7
Buzzer Circuit LED Circuit Flashing Circuit

Flashing circuit
Amber
Green
White

Red
Blue

Buzzer
Power supply wire

control
Common flashing wire

Power supply wire

circuit Power
supply
Amber LED
Green LED
White LED

Blue LED
Buzzer 1

Buzzer 2

Red LED

Signal Flow Legend


: Illuminated Amber LED
: Flashing Red LED
: Buzzer 1 Sounds
DC24V
(Note) . The diagram illustrates flashing, Illuminating and specifications
for Buzzer equipped models.
Functions will vary upon product specifications.
. The diagram is only an example.

4
6 Installation
CAUTION
The buzzer is unidirectional.
The following requirements are Position the signal light so that
necessary for proper installation. the buzzer diaphragm is facing
the desired sound direction.
. Install the signal light where ( B Buzzer included
excessive vibration is not specifications)
present.
Use a soft cloth, etc., dampened
. Install the signal light on a with water to wipe the main signal
sturdy surface. light unit.
(Do not use cleaners containing
. Install the signal light on a chemicals such as thinner,
alcohol, gasoline or oil.)
level surface.
. Thinner
. Alcohol
. Gasoline
. Oil
Install the signal light in an upright
position.
Sound Pressure might decrease in an
environment where water is
splashing.

To ensure the waterproofing For use on a flat surface of a type 1


performance of this product, enclosure when device is installed
do not remove the O-ring or as intended.
the waterproof packing.

Type1 Enclosure

General Installation
(Note) Refer to the individual Instruction manuals for
the Platform bracket and Wall-mount bracket
2 Provide proper hardware needed for mounting.

when installing.
1 Verify the signal light installation position.

½”NPT
Rotate to separate.
refer to Section 4
for removing the
socket base.

3 Prepare mounting surface as required.

Tip Attach and


. Use the following tips to check the following: install the
. Will it obstruct other equipment? pole into
. Can the wiring be routed properly? the desired
. Where is the buzzer direction facing? location.
( B Buzzer included specifications)
. Make sure ½”NPT mounting is provided.

Continued on next page

5
4 Attach the main unit to the mount.

Tip
. For the C M12 connector option, thread the cable through the
Main unit wiring hole and mount before connecting it to the main unit.
. Refer to “ 4 Stackable Tower Construction” ( P.4) for details
on how to remove the mount.
. Be careful not to pinch the lead wires or cable.
. Adjust the sound to the desired level.
(Refer to " 8 Volume Adjustment" ( P.10))
( B Buzzer included specifications)
. Make sure to allow some slack for the lead wires or cable in
order to adjust the volume.
Thread the lead wires through the socket base and pipe, ( B Buzzer included specifications)
before installing the main unit to the mount.

6
7 Wiring
WARNING
Prior to wiring, ensure the power DC? Verify the power supply voltage and
supply is disconnected from the AC? whether it is direct current or
signal light. alternating current.
What
voltage?

CAUTION
Common
Never apply a voltage to the To protect the power supply and
flashing wire "flashing common" wire. other internal circuitry, be sure to
Failure to observe will result in damage install an external fuse.
to the circuitry. ( F Illumination
and flashing specifications)

Power Common Never connect the power supply


supply
wire
flashing wire wire to the "flashing common" wire.
Failure to observe will result in damage Do not pull on the lead wire. Do not push lead wires up
to the circuitry. ( F Illumination into the main unit.
and flashing specifications)

When there are unused lead wires


for the LED tiers, be sure to
separately insulate the ends of each
unused lead wire.

Spare

Common
Do not connect the "flashing
flashing wire Buzzer common" wire with the buzzer wire.
( B Buzzer included
specifications)

Quick Tips
For models with the buzzer, if
If the leakage current from buzzer 1 and buzzer 2 are triggered
equipment, such as a PLC unit simultaneously,
output, is 1mA or more, the LEDs buzzer 1 will take priority.
1mA
may show a dim illumination,
( B Buzzer included specifications)
but it is not the sign of a problem. Beep 1
A
Buzzer 1: Intermittent Beep 1
Buzzer 2: Intermittent Beep 2

ON
Input
OFF
The LEDs and the buzzers will only When adding an additional length
operate when a signal input is of wire, use the appropriate wire
present. lengths and wire diameters to
ON
(They do not operate on one-shot ensure there are no voltage drops.
Output OFF signal pulses.)
LEDs
and
buzzers ON

OFF

7
Wiring Examples
Wiring examples are shown in accordance to the signal light model and external contact type.
If the signal light is being used under special conditions and there are any questions, contact our PATLITE office
prior to performing any wiring.
Do not connect unused lead wires to external contacts when unnecessary.
CAUTION
Insulate all unused lead wires with insulation tape, etc.

General Wiring Example M12 Connector Pin Layout


B Buzzer included
Red LED Red Buzzer 1 White LED specifications only

PIN No. Green LED 2 1 Blue LED Tip


Name of
( C M12 connector 8 7 . It is recommended to use
function
specifications) 3 the optional connector
Amber LED 6 with cable for wiring.
Refer to the “M12 Connector Pin 4
Layout” illustration to the right. 5 Red LED ( “ 13 Option Parts”
Lead wire color
Power Supply Wire (P.15))
(H Lead wires specifications)

Product Illumination only Model ( B) W


LS7-502 9
specifications Buzzer not included / B Buzzer included

External Contact Relay Contact External Contact PLC (NPN transistor type)

Transistor Symbol
LS7 LS7
N
P
N

For Illumination
For Illumination Output Unit
No Buzzer Buzzer External Contact No Buzzer Buzzer
PLC
Red LED Red / ⑥ Red LED Red / ⑥
Amber LED Orange / ④ Amber LED Orange / ④
Green LED Green / ③ Green LED Green / ③
Blue LED Blue /⑦ Blue LED Blue /⑦
White LED White / ① White LED White / ①
Buzzer 1 Purple / ② Buzzer 1 Purple / ②

Power Power
Supply Wire Yellow / ⑤ Supply Wire Yellow / ⑤
Fuse 1A Fuse 1A
DC 24V DC 24V
B Buzzer included (No polarity) B Buzzer included
specifications only specifications only

External Contact PLC (PNP transistor type)

Transistor Symbol
LS7
P
N
P

For Illumination
Output Unit
No Buzzer Buzzer
PLC
Red LED Red / ⑥
Amber LED Orange / ④
Green LED Green / ③
Blue LED Blue /⑦
White LED White / ①
Buzzer 1 Purple / ②

Power
Supply Wire Yellow / ⑤
Fuse 1A
DC 24V
B Buzzer included
specifications only

8
Product F Illumination and Flashing Model LS7 -5 0 2 FB WH9
specifications B Buzzer Included
(Note) When using illuminating and flashing features together, it is necessary to have separate output units
for the illuminating and flashing functions at the PLC side.
External Contact Relay Contact External Contact PLC (NPN transistor type)
For flashing
LS7 Do not apply voltage! External contact LS7 Do not apply voltage! PLC

For
flashing
Output
Unit
Common Common
Flashing Wire Brown Flashing Wire Brown

Red LED Red Red LED Red


Amber LED Orange Amber LED Orange
Green LED Green Green LED Green For
Illumination
Blue LED Blue Blue LED Blue
Output
White LED White White LED White Unit
Buzzer 1 Purple Buzzer 1 Purple
Buzzer 2 Sky-blue Buzzer 2 Sky-blue

Power Power
Supply Wire Gray Supply Wire Gray
Transistor Symbol
Power DC 24V Power DC 24V N
Supply Wire Yellow For Illumination Supply Wire Yellow P
External Contact N
Fuse 1A (No polarity) Fuse 1A

External Contact PLC (PNP transistor type)

LS7 Do not apply voltage! PLC

For
flashing
Output
Unit
Common
Flashing Wire Brown

Red LED Red


Amber LED Orange
Green LED Green For
Illumination
Blue LED Blue
Output
White LED White Unit
Buzzer 1 Purple
Buzzer 2 Sky-blue

Power
Supply Wire Gray
Transistor Symbol
Power DC 24V P
Supply Wire Yellow N
P
Fuse 1A

9
8 Volume Adjustment
The volume adjustment of the buzzer is done by
inserting a screwdriver into the volume adjustment hole Buzzer case
Volume Adjustment Hole
of the buzzer case.
Refer to “ 4 Stackable Tower Construction” ( P.4) for
details on removing the buzzer case.

Maximum Minimum

The volume is set at


maximum prior to
Underside View shipment from the factory.
screwdriver

Do not rotate the volume any further than its


CAUTION
specified range of movement when adjusting.

10
9 Inspection
To ensure safe operation, it is recommended to perform the following:

Inspection Item Inspection Repair


Are all the LEDs illuminated? Refer to the “ 10 Troubleshooting” section ( P.12) if they do not illuminate.
Are all the buzzer functions sounding?
(For models equipped with the Buzzer
Refer to the “ 10 Troubleshooting” section ( P.12) if they do not sound.
function, only)

Check the outside appearance. Is there any If there is any external damage such as cracks, or missing parts, stop using
damage? the signal light and replace the necessary parts or the main unit.
(Refer to “ 12 Replacement Parts” ( P.14 ))

11
10 Troubleshooting
If a problem occurs, check the following table to remedy the problem before calling for service.

No. Problem Where to Check Solution


Refer to “ 7 Wiring” ( P.7-9) to double-check
Is the wiring properly connected?
the wiring connection.
The LEDs do not illuminate.
1 Is the power supply at the correct voltage? Be sure to use a 24V DC power supply.

Is the fuse blown? If the fuse is blown, replace it.

A different LED light turned


Refer to “ 7 Wiring” ( P.7-9) to double-check
2 on from what I was Is the wiring properly connected?
the wiring connection.
expecting.

Refer to “ 7 Wiring” ( P.7-9) to double-check


Is the wiring properly connected?
the wiring connection.

The buzzer does not sound. Is the power supply at the correct voltage? Be sure to use a 24V DC power supply.
3
Is the fuse blown? If the fuse is blown, replace it.

Only signal lights with a B in the model type


Double-check the product model.
are equipped with a buzzer function.

The buzzer volume is Refer to “ 8 Volume Adjustment” ( P.10) for


4 Is the buzzer volume set to minimum?
too low. adjusting the volume.

Priority is given to “buzzer 1” when


When I connect to the Is the external contact for “Buzzer 1” turning on? simultaneous signal inputs to “buzzer 1” and
5 “buzzer 2” connection, “buzzer 2” are applied.
“buzzer 1” will sound. Refer to “ 7 Wiring” ( P.7-9) to double-check
Is the wiring properly connected?
the wiring connection.

Refer to “ 7 Wiring” ( P.7-9) to double-check


Is the wiring properly connected?
the wiring connection.

Priority is given to the lighting input over the


6 The LEDs do not flash. Are the external contacts for lighting turning on? flashing input when simultaneous signals are
applied.

Only signal lights with an F in the model type


Double-check the product model.
are equipped with a flashing function.

Refer to “ 4 Stackable Tower Construction”


How is the outer cover and Only designated parts of the signal light's stackable ( P.4) for proper assembly and disassembly.
7
base (buzzer case) removed? structure allows removable parts. (Never disassemble or remove any parts other
than the stackable parts.)

If the problem is not corrected, even after the above solutions have been performed, use the table below to make detailed notes of the
product, its problem, and then contact either the place of purchase or your nearest PATLITE Sales Representative.
The place of purchase The PATLITE Office (Refer to back cover)

Product Details
Product name LED SIGNAL LIGHT Purchase Date / /
Model ( “ 2 Model Number Configuration” (P.3)) Symptoms of Problem With as much detail as possible

12
11 Specifications
Product Specifications
Model LS7-□02 (Blank/D/S) WC9(D/N) LS7-□02 (Blank/D/S) WH9(D/N) LS7-□02 (Blank/D/S) BWC9(D/N) LS7-□02 (Blank/D/S) FBWH9(D/N)

UL Registration model LS7-_02(Blank/D/S)WC9(D/N) LS7-_02(Blank/D/S)WH9(D/N) LS7-_02(Blank/D/S)BWC9(D/N) LS7-_02(Blank/D/S)FBWH9(D/N)

Rated Voltage DC 24V

Installation Location Indoor use only

Maximum surrounding
60℃
air temperature rating

Power LED 30 mA per tier (Red:20mA)


Consumption Buzzer 40mA 30mA

Standby Current 10mA※

Buzzer Duration 520msec.


Sound Pressure Buzzer 1 : Approx.82dB
Approx.82dB Buzzer 2 : Approx.85dB
(at 1m)
Inrush Current 150mA

Flashing Frequency 60±12 times/min.

Wire Type UL1007

Wire Gauge AWG22


Mass Approx.460g Approx.490g

Ingress Protection Rating IP69K - Suitable for high pressure, high temperature washdowns

※The standby current is based on a product with an operating LED, with the buzzer included, the current will be higher.

External Contact Specifications

Contact Relay Type (Switch) PLC Output Unit


Rated Voltage Rated Current Rated Voltage Rated Current Leakage
Load LED Buzzer Load LED Buzzer Current
100 mA 100 mA 200 mA 0.1 mA
or more
200 mA DC24V or more
DC24V per level or more or less
per level or more

13
12 Replacement Parts
The following are replacement parts available for this product. For further details, visit www.patlite.com.

Outer Cover O-ring 1/2” NPT Bracket NOTE:


Please refer to section
4 Stackable Tower Contruction,
P.4, for instructions on how to attach
to the base to the 1/2” NPT Adaptor.

WARNING:
Incorrect installation of the 1/2” NPT
Adaptor can result in the loss of
O-ring included the IP69K rating.

PART #: B45110011-F1 PART #: Z35721039-F1 PART # (Natural White):


SZI-130-IP69K-N
PART # (Dark Gray):
SZI-130-IP69K-D

14
13 Option Parts
This product includes the following option parts. For details, refer to www.patlite.com.

M12 Connector with Cable


PART NUMBERS:
SZ-120-02 2m 8 pole M12 female cable with leads

SZ-120-05 5m 8 pole M12 female cable with leads


SZ-120-10 10m 8 pole M12 female cable with leads

(Lengths : 2m . 5m . 10m)

14 Dimensions for Mounting*

* Drawing is not to scale and does not represent the actual size.

15
20130 S. Western Ave. Torrance, CA 90501, U.S.A. TEL: 310-328-3222 EMAIL: sales@patlite.com

The latest product information can be viewed www.patlite.com


on our company's website.

(Note) ・Dimensions, specifications and structure are subject to change for improvement without notice.
・PATLITE is a trademark or registered trademark of the PATLITE Corporation in JAPAN and/or
other countries.

Copyright © 2011 PATLITE Corporation All Rights Reserved.

PLUS-170201-B