Ls 79
Ls 79
Model
L S 7- 9
IP69K RATED LED SIGNAL TOWER LIGHT
INSTRUCTION MANUAL
[ Maintenance Version ]
Installation Operation Maintenance
Page
1 Safety Precautions 2
2 Model Number
Configuration
3
3 Part Names and
Outer Appearance
3
4 Stackable Tower
Construction
4
5 Block Diagram 4
6 Installation 5-6
7 Wiring 7-9
8 Volume Adjustment 10
Notice to Customer
Thank you very much for purchasing PATLITE products.
9 Inspection 11
It is recommended that the installation and wiring be
performed by a professional contractor if construction
10 Troubleshooting 12
work is involved.
Prior to installation or using this product, please read
11 Specifications 13
this manual thoroughly to ensure correct use.
After reviewing this manual, if there are any questions 12 Replacement Parts 14
regarding this product, please contact the nearest
PATLITE office listed on the back cover of this manual. 13 Optional Parts 15
Notice to Contractor
Read this manual carefully prior to installation.
14 Dimensions for Mounting 15
Be sure to return this manual to the customer.
1 Safety Precautions
Safety Precautions
WARNING Failure to observe the following may result in death or serious injury.
To ensure proper safety while using To ensure safety when the signal
OK ! the signal light, observe the light is installed onto equipment,
following: observe the following.
. Do not use the signal light as
. Perform periodic leverage when climbing up onto the
pre-maintenance. equipment. Failure to comply will
( “ 9 Inspection” (P.11)) result in falling from a high place, or
damage to the product.
. As a precaution, we suggest using . When performing tasks such as
this product with other back up opening the covers of the
safety equipment equipment, be careful not to snag
anything on the signal light. Failure
to observe may result in damage.
CAUTION If the following are not observed, injury to personnel or physical damage may result.
2
2 Model Number Configuration
Model Number of Rated Body Flashing Buzzer Mounting Wiring Adaptor LED Color
LED Modules Voltage Color Color
5
LED colors in order from top to bottom
5 LED Tiers (5 tiers) Red, Amber, Green, Blue and White
(3 tiers) Red, Amber and Green, blank (N),
3
blank (N)
3 LED Tiers
H
Common to all * [ 9N ] for Off-white tower
D Dark Gray none Illumination Only none
Buzzer not
Included models
Lead Wires [ 9D ] for Silver tower
[ 9D ] for Dark Gray tower
S
Direct * [ F ] Illumination and
Silver F Illumination and
Flashing B Buzzer
Included Installation Only Flashing function is only
available for the [ H ]
lead wires specifications
1/2” NPT x 16
Socket Base
(p/n: SZI-130-IP69K)
M12 Connector 1
(Note) The Signal Light LED array is not replaceable. (Units: mm)
3
4 Stackable Tower Construction
What is a 'Stackable Structure'?
The ‘stackable structure’ is a feature which allows the main signal light
unit and the outer cover to be separated with just a single touch.
(Previous signal lights require tools to disassemble, such as removing
screws.)
Rotate
Hold the base and the 1/2” NPT socket base, and rotate until Pull the base in the upward direction to remove it.
the bar marks are aligned. Tip
. Do not twist the base too hard when removing it.
Tip
. The lock may be stiff.
. When reinstalling, fully rotate the base until the triangle mark
Tip For models equipped with a buzzer, the signal light is
and bar mark are aligned.
equipped with a buzzer case instead of a base.
WARNING: Incorrect installation of the 1/2” NPT Adaptor can result in the
loss of the IP69K rating.
5 Block Diagram
The following illustrates the internal block diagram for the signal light. Use it as reference when wiring.
LS7
Buzzer Circuit LED Circuit Flashing Circuit
Flashing circuit
Amber
Green
White
Red
Blue
Buzzer
Power supply wire
control
Common flashing wire
circuit Power
supply
Amber LED
Green LED
White LED
Blue LED
Buzzer 1
Buzzer 2
Red LED
4
6 Installation
CAUTION
The buzzer is unidirectional.
The following requirements are Position the signal light so that
necessary for proper installation. the buzzer diaphragm is facing
the desired sound direction.
. Install the signal light where ( B Buzzer included
excessive vibration is not specifications)
present.
Use a soft cloth, etc., dampened
. Install the signal light on a with water to wipe the main signal
sturdy surface. light unit.
(Do not use cleaners containing
. Install the signal light on a chemicals such as thinner,
alcohol, gasoline or oil.)
level surface.
. Thinner
. Alcohol
. Gasoline
. Oil
Install the signal light in an upright
position.
Sound Pressure might decrease in an
environment where water is
splashing.
Type1 Enclosure
General Installation
(Note) Refer to the individual Instruction manuals for
the Platform bracket and Wall-mount bracket
2 Provide proper hardware needed for mounting.
when installing.
1 Verify the signal light installation position.
½”NPT
Rotate to separate.
refer to Section 4
for removing the
socket base.
5
4 Attach the main unit to the mount.
Tip
. For the C M12 connector option, thread the cable through the
Main unit wiring hole and mount before connecting it to the main unit.
. Refer to “ 4 Stackable Tower Construction” ( P.4) for details
on how to remove the mount.
. Be careful not to pinch the lead wires or cable.
. Adjust the sound to the desired level.
(Refer to " 8 Volume Adjustment" ( P.10))
( B Buzzer included specifications)
. Make sure to allow some slack for the lead wires or cable in
order to adjust the volume.
Thread the lead wires through the socket base and pipe, ( B Buzzer included specifications)
before installing the main unit to the mount.
6
7 Wiring
WARNING
Prior to wiring, ensure the power DC? Verify the power supply voltage and
supply is disconnected from the AC? whether it is direct current or
signal light. alternating current.
What
voltage?
CAUTION
Common
Never apply a voltage to the To protect the power supply and
flashing wire "flashing common" wire. other internal circuitry, be sure to
Failure to observe will result in damage install an external fuse.
to the circuitry. ( F Illumination
and flashing specifications)
Spare
Common
Do not connect the "flashing
flashing wire Buzzer common" wire with the buzzer wire.
( B Buzzer included
specifications)
Quick Tips
For models with the buzzer, if
If the leakage current from buzzer 1 and buzzer 2 are triggered
equipment, such as a PLC unit simultaneously,
output, is 1mA or more, the LEDs buzzer 1 will take priority.
1mA
may show a dim illumination,
( B Buzzer included specifications)
but it is not the sign of a problem. Beep 1
A
Buzzer 1: Intermittent Beep 1
Buzzer 2: Intermittent Beep 2
ON
Input
OFF
The LEDs and the buzzers will only When adding an additional length
operate when a signal input is of wire, use the appropriate wire
present. lengths and wire diameters to
ON
(They do not operate on one-shot ensure there are no voltage drops.
Output OFF signal pulses.)
LEDs
and
buzzers ON
OFF
7
Wiring Examples
Wiring examples are shown in accordance to the signal light model and external contact type.
If the signal light is being used under special conditions and there are any questions, contact our PATLITE office
prior to performing any wiring.
Do not connect unused lead wires to external contacts when unnecessary.
CAUTION
Insulate all unused lead wires with insulation tape, etc.
External Contact Relay Contact External Contact PLC (NPN transistor type)
Transistor Symbol
LS7 LS7
N
P
N
For Illumination
For Illumination Output Unit
No Buzzer Buzzer External Contact No Buzzer Buzzer
PLC
Red LED Red / ⑥ Red LED Red / ⑥
Amber LED Orange / ④ Amber LED Orange / ④
Green LED Green / ③ Green LED Green / ③
Blue LED Blue /⑦ Blue LED Blue /⑦
White LED White / ① White LED White / ①
Buzzer 1 Purple / ② Buzzer 1 Purple / ②
Power Power
Supply Wire Yellow / ⑤ Supply Wire Yellow / ⑤
Fuse 1A Fuse 1A
DC 24V DC 24V
B Buzzer included (No polarity) B Buzzer included
specifications only specifications only
Transistor Symbol
LS7
P
N
P
For Illumination
Output Unit
No Buzzer Buzzer
PLC
Red LED Red / ⑥
Amber LED Orange / ④
Green LED Green / ③
Blue LED Blue /⑦
White LED White / ①
Buzzer 1 Purple / ②
Power
Supply Wire Yellow / ⑤
Fuse 1A
DC 24V
B Buzzer included
specifications only
8
Product F Illumination and Flashing Model LS7 -5 0 2 FB WH9
specifications B Buzzer Included
(Note) When using illuminating and flashing features together, it is necessary to have separate output units
for the illuminating and flashing functions at the PLC side.
External Contact Relay Contact External Contact PLC (NPN transistor type)
For flashing
LS7 Do not apply voltage! External contact LS7 Do not apply voltage! PLC
For
flashing
Output
Unit
Common Common
Flashing Wire Brown Flashing Wire Brown
Power Power
Supply Wire Gray Supply Wire Gray
Transistor Symbol
Power DC 24V Power DC 24V N
Supply Wire Yellow For Illumination Supply Wire Yellow P
External Contact N
Fuse 1A (No polarity) Fuse 1A
For
flashing
Output
Unit
Common
Flashing Wire Brown
Power
Supply Wire Gray
Transistor Symbol
Power DC 24V P
Supply Wire Yellow N
P
Fuse 1A
9
8 Volume Adjustment
The volume adjustment of the buzzer is done by
inserting a screwdriver into the volume adjustment hole Buzzer case
Volume Adjustment Hole
of the buzzer case.
Refer to “ 4 Stackable Tower Construction” ( P.4) for
details on removing the buzzer case.
Maximum Minimum
10
9 Inspection
To ensure safe operation, it is recommended to perform the following:
Check the outside appearance. Is there any If there is any external damage such as cracks, or missing parts, stop using
damage? the signal light and replace the necessary parts or the main unit.
(Refer to “ 12 Replacement Parts” ( P.14 ))
11
10 Troubleshooting
If a problem occurs, check the following table to remedy the problem before calling for service.
The buzzer does not sound. Is the power supply at the correct voltage? Be sure to use a 24V DC power supply.
3
Is the fuse blown? If the fuse is blown, replace it.
If the problem is not corrected, even after the above solutions have been performed, use the table below to make detailed notes of the
product, its problem, and then contact either the place of purchase or your nearest PATLITE Sales Representative.
The place of purchase The PATLITE Office (Refer to back cover)
Product Details
Product name LED SIGNAL LIGHT Purchase Date / /
Model ( “ 2 Model Number Configuration” (P.3)) Symptoms of Problem With as much detail as possible
12
11 Specifications
Product Specifications
Model LS7-□02 (Blank/D/S) WC9(D/N) LS7-□02 (Blank/D/S) WH9(D/N) LS7-□02 (Blank/D/S) BWC9(D/N) LS7-□02 (Blank/D/S) FBWH9(D/N)
Maximum surrounding
60℃
air temperature rating
Ingress Protection Rating IP69K - Suitable for high pressure, high temperature washdowns
※The standby current is based on a product with an operating LED, with the buzzer included, the current will be higher.
13
12 Replacement Parts
The following are replacement parts available for this product. For further details, visit www.patlite.com.
WARNING:
Incorrect installation of the 1/2” NPT
Adaptor can result in the loss of
O-ring included the IP69K rating.
14
13 Option Parts
This product includes the following option parts. For details, refer to www.patlite.com.
(Lengths : 2m . 5m . 10m)
* Drawing is not to scale and does not represent the actual size.
15
20130 S. Western Ave. Torrance, CA 90501, U.S.A. TEL: 310-328-3222 EMAIL: sales@patlite.com
(Note) ・Dimensions, specifications and structure are subject to change for improvement without notice.
・PATLITE is a trademark or registered trademark of the PATLITE Corporation in JAPAN and/or
other countries.
PLUS-170201-B