aerospace

climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding

Thermostatic and Automatic


Expansion Valves
Catalog E-1, July 2012
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 1

Table of Contents

Thermostatic Expansion Valves (TEVs) and


Constant Pressure (Automatic) Expansion Valves (AEVs)
Visual Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Thermostatic Expansion Valves
Model Number Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C(E) Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
EC(E) Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SC(E) Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
C Series Interchangeable Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
HC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
EBSE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
OE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Constant Pressure (Automatic) Expansion Valves
A Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Terms of Sale With Warranty Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

⚠WARNING – USER RESPONSIBILITY


Failure or improper selection or improper use of the products described herein or related items can cause death, personal injury and property damage.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user
is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are
governed by the provisions stated in the detailed “Offer of Sale” available at www.parker.com.

FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLY


Catalog E-1, July 2012, supersedes Catalog E-1, October 2007 and all prior publications.
Page 2 / Catalog E-1, Thermostatic & Automatic Expansion Valves

Visual Table of Contents


N Series TEV C(E) Series TEV EC(E) Series TEV
page 4 page 5 page 6
Applications: Applications: Applications:
Low Profile Coolers, Rail and Transport Supermarket Cases,
Ice Machines, Refrigeration, Transport Refrigeration,
Beverage Dispensers Supermarket Cases, Walk-in Coolers
Walk-in Coolers

SC(E) Series TEV C Series H Series TEV


page 8 Interchangeable TEV page 12
Applications: page 9 Applications:
Supermarket Cases, Applications: Air Conditioning,
Walk-in Freezers, Air Conditioning, Heat Heat Pumps, Bi-flow
Ice Machines Pumps, Supermarket (Package Systems)
Cases, Walk-in Coolers

HC Series TEV EBSE Series TEV OE Series TEV


page 12 page 14 page 15
Applications: Applications: Applications:
Air Conditioning, Air Conditioning, Air Conditioning,
Heat Pumps Industrial Chillers, Industrial Chillers,
Commercial Commercial
Refrigeration Refrigeration

AT Series AEV A7 Series AEV AS Series AEV


page 22 page 22 page 22
Applications: Applications: Applications:
Ice Cream/Slush Ice Cream/Slush Ice Cream/Slush
Machines, Machines, Machines,
Hot Gas Bypass, Hot Gas Bypass, Hot Gas Bypass,
Freeze Protection, Freeze Protection, Freeze Protection,
Refrigerant Reclaim, Refrigerant Reclaim, Refrigerant Reclaim,
PTAC/PTHP, High Cycle PTAC/PTHP, High Cycle Vending, Ice Machines

A1 Series AEV A2 Series AEV A3 Series AEV


page 22 page 23 page 23
Applications: Applications: Applications:
Ice Cream/Slush Ice Cream/Slush Ice Cream/Slush
Machines, Machines, Machines,
Hot Gas Bypass, Hot Gas Bypass, Hot Gas Bypass,
Freeze Protection, Freeze Protection, Freeze Protection,
Refrigerant Reclaim, Refrigerant Reclaim, Refrigerant Reclaim,
Vending, Ice Machines Vending, Ice Machines Vending, Ice Machines

A4 Series AEV
page 23
Applications:
Ice Cream/Slush
Machines,
Hot Gas Bypass,
Freeze Protection,
Refrigerant Reclaim,
Vending, Ice Machines
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 3

TEV Model Number Selection Guide


Nomenclature (Example)

SC E – A – V X 100 B 20
Valve External Orifice Refrigerant Valve Maximum Bleed Bleed
Model Equalizer Designation Charge Operating (Optional) Capacity
(Optional) OR Pressure
Nominal Capacity (MOP)
in Tons

(E) for Externally Equalized


Evaporator pressure drop > 3 psi Bleed
BLANK for Internally Equalized Denoted by “B”.
Evaporator pressure drop < 3 psi Not available on all TEVs.
or smaller tonnage evaporators See bleed capacity.
Used for equalizing system
See Catalog E-1a, TEV and AEV during off cycle (compressor
Theory & Application. unloading). Consult Parker.
See Catalog E-1a, TEV and
N, C, AEV Theory & Application.
Capacity
EC, SC Parker’s expansion
EBS, O valves offer a range of Bleed Capacity
H, HA capacities from 1/8 ton Percentage based on nominal
HC, HCA to 70 tons depending on capacity of valve specified by
refrigerant. See pages manufacturer or Parker.
17-21 for capacity tables.

Rainbow Charge™
Refrigerant Designation Charge Operating Temperature Range
R-134a, R-401A (MP39),
J
R-401B (MP66), R-12 VX100, JX60, SX110, ZX200
V R-407C (AC9000), R-22 Air Conditioning
R-125, R-404A (HP62), VX35, SX35
S R-402A (HP80), R-402B Low Temp. Ref.
(HP81), R-507 (AZ50) VZ, SZ
Z R-410A (AZ20) Low Temp. Ref.
VW, JW, SW
Refrigerant
Color Code All purpose liquid
R-12 - yellow
R-134a - light blue -40 -30 -20 -10 0 10 20 30 40 50 60
R-22 - green Evaporator Temperature °F
R-402A - light brown (sand)
R-402B - olive
R-404A - orange
R-407C - medium brown
R-410A - rose
R-507 - teal

✝Charge Type
"W” (all-purpose) liquid charge maintains nearly flat superheat control over a -10°F to +60°F (-23°C to +15°C) evaporator temperature range.
“Z” (low temperature) charge provides fast pulldown benefits like a gas charge with the non-migrating benefits of a liquid charge; usable over a -40°F to 0°F
(-40°C to -18°C) evaporator temperature range.
“X” (damped response) gas charge provides a pressure limiting (MOP) charge with anti-hunt characteristics over a -40°F to +60°F (-40°C to +15°C) evaporator
temperature range.
Notes: M.O.P. not available on “W” or “Z” charge.
1. Maximum operational pressure 500 psig (35 bar) high side and 275 psig (19 bar) low side.
2. Maximum storage temperature 130°F (55°C).
3. Consult Parker for pressure and temperature exceptions.
4. Do not use “W” or “Z” liquid charges in applications where bulb temperatures can exceed 130°F (55°C).
For these applications use type “X” MOP gas charge only.
Page 4 / Catalog E-1, Thermostatic & Automatic Expansion Valves

N Series
This small flare brass valve series is ideally suited where space is at a premium.
Its stainless steel power element and compact body has always made it the first
choice for installation in commercial refrigeration systems. External equalized
models are provided with a 30" capillary and 1/4" SAE flare nut, eliminating the
need to run a separate equalizer line. Medium, low & MOP “X” charges are avail-
able as noted below.

Applications Features and Benefits


■■ Low Profile Coolers ■■ Compact body
■■ Beverage Dispensers ■■ Inlet strainer
■■ Beverage Boxes ■■ Factory set superheat
■■ Small Chillers ■■ Accurate and stable control
■■ Ice Machines ■■ Right angle configuration
■■ Small Freezers ■■ 30" capillary tube
■■ Weight: 5.0 oz. / .14 kg

Specifications
Nominal Valve Description Connection - (Inches)
Refrigerant Rainbow
Refrigerant Capacity Internally Externally
Designation Charges™ Inlet Outlet
(Tons) Equalized Equalized
R-12 1/4 N-1/4-J
R-134a — W 1/4 SAE
J 1/2 SAE
R-401A 1/2 N-1/2-J X60
R-401B 2 N-2-J NE-2-J 3/8 SAE
R-402A 1/2 N-1/2-S 1/4 or 3/8 SAE
R-402B — W
1/4 N-1/4-S 1/4 SAE
R-404A S Z 1/2 SAE
R-502 X110
R-507 2 N-2-S NE-2-S 3/8 SAE

1/4 N-1/4-V 1/4 SAE


W
R-22 1/2 N-1/2-V —
V Z 1/4 or 3/8 SAE 1/2 SAE
R-407C 1 N-1-V
X100
3 N-3-V NE-3-V 3/8 SAE

Dimensions
0.093” / 2.4 mm OD
Capillary Tube 2.50”
64 mm

0.50”
13 mm

1.50”
38 mm

Inlet

2.40”
61 mm
1.38”
35 mm
Outlet
1.27”
32 mm
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 5

C(E) Series
The C(E) series incorporates a brass body with a 90° elbow inlet and SAE flare
fittings using balanced port construction, allowing operation over varying load
conditions. Designed for use on small refrigeration and or air conditioning systems,
the external equalized models are provided with a 1/4" SAE male connection.

Applications Features and Benefits


■■ Small Refrigeration Systems ■■ Balanced port design
■■ Slush Machines ■■ Removable power element
■■ Air Conditioning Units ■■ Inlet strainer – 100 mesh
■■ Freezers ■■ 60" capillary tube
■■ Walk-in Coolers ■■ Field adjustable superheat
■■ Refrigerated Cases ■■ 1/4" SAE external equalizer
■■ Rail & Transport Refrigeration ■■ Weight: 1.0 lbs / 0.45 kg

Specifications
Capacity Range Valve Description Connection - (Inches) External
Nominal
Refrigerant Orifice of Valve to Rainbow Equalizer
Refrigerant Capacity Internally Externally
Designation Designation be Replaced Charges™ Inlet Outlet Connection
(Tons) Equalized Equalized
(Tons) (Inches)
AA 1/4 1/6 to 1/4 C-AA-J CE-AA-J 1/4 SAE
R-12 A 1 1/2 to 1 C-A-J CE-A-J
R-134a W 1/2 SAE
J B 2 1 to 2 C-B-J CE-B-J 1/4 SAE
R-401A X60 3/8 SAE
R-401B C 3 2 to 3 C-C-J CE-C-J
D 5 3 to 5 C-D-J CE-D-J 5/8 SAE
AA 1/4 1/6 to 1/4 C-AA-S CE-AA-S 1/4 SAE
R-402A A 1 1/2 to 1 C-A-S CE-A-S W
R-402B Z 1/2 SAE
S B 2 1 to 2 C-B-S CE-B-S 1/4 SAE
R-404A X110 3/8 SAE
R-502 C 3-1/2 2 to 3-1/2 C-C-S CE-C-S X35
D 6 3-1/2 to 6 C-D-S CE-D-S 5/8 SAE
AA 1/2 1/3 to 1/2 C-AA-V CE-AA-V 1/4 SAE
A 1-1/2 3/4 to 1-1/2 C-A-V CE-A-V W
R-22 1/2 SAE
Z
R-407C V B 3 1-1/2 to 3 C-B-V CE-B-V 1/4 SAE
X100 3/8 SAE
R-422D C 5 3 to 5 C-C-V CE-C-V X35
D 8 5 to 8 C-D-V CE-D-V 5/8 SAE

Dimensions Fitting Size A B C D

1/4 SAE Inlet Strainer 1.11” 1.54” 1.15”


60° 1/4 SAE —
P/N 3008-000 28 mm 39 mm 29 mm

3/8 SAE Inlet Strainer 1.27” 0.75”


3/8 SAE — —
P/N 1538-000 32 mm 19 mm
1.82”
1/2 SAE — — —
46 mm
C
1.98”
5/8 SAE — — —
1.93” 50 mm
49 mm

Replacement Elements
Refrigerant
Element
Designation
3.36”
85 mm KT-46-VW
2.17” V
KT-46-VX100
55 mm 2.20”
1.83 KT-46-JW
46 mm 56 mm J
KT-46-JX60
D KT-46-SZ
S KT-46-SW
A B KT-46-SX35
Page 6 / Catalog E-1, Thermostatic & Automatic Expansion Valves

EC(E) Series
The EC(E) series features extended ODF solder connections, brass body and
balanced port design. It is suited for both refrigeration and air conditioning
applications.

Applications Features and Benefits


■■ Small Chillers ■■ Extended ODF connections
■■ Air Conditioning Units ■■ Balanced port design
■■ Freezers ■■ 60" capillary tube
■■ Walk-in Boxes ■■ Removable power element
■■ Refrigerated Cases ■■ Field adjustable superheat
■■ Mobile Refrigeration ■■ 1/4" ODF external equalizer
■■ Weight: 1.0 lbs / 0.45 kg

Specifications
Capacity Range Valve Description External
Nominal Connection - (Inches)
Refrigerant Orifice of Valve to Rainbow Bold figures are standard Equalizer
Refrigerant Capacity Internally Externally
Designation Designation be Replaced Charges™ Connection
(Tons) Equalized Equalized
(Tons) Inlet Outlet (Inches)
AA 1/4 1/6 to 1/4 EC-AA-J ECE-AA-J 1/4 ODF
1/2 ODF
A 1 1/2 to 1 EC-A-J ECE-A-J 3/8 ODF
3/8 ODF 1/2 ODF
R-12 B 2 1 to 2 EC-B-J ECE-B-J
1/2 ODF 5/8 ODF
R-134a W
J 3/8 ODF 1/2 ODF 1/4 ODF
R-401A X60
R-401B C 3 2 to 3 EC-C-J ECE-C-J 1/2 ODF 5/8 ODF
5/8 ODF 7/8 ODF
1/2 ODF
D 5 3 to 5 N/A ECE-D-J 7/8 ODF
5/8 ODF
AA 1/4 1/6 to 1/4 EC-AA-S ECE-AA-S 1/4 ODF
1/2 ODF
A 1 1/2 to 1 EC-A-S ECE-A-S 3/8 ODF
R-402A 3/8 ODF 1/2 ODF
B 2 1 to 2 EC-B-S ECE-B-S W
R-402B 1/2 ODF 5/8 ODF
Z
R-404A S 3/8 ODF 1/2 ODF 1/4 ODF
X110
R-502 C 3-1/2 2 to 3-1/2 EC-C-S ECE-C-S 1/2 ODF 5/8 ODF
X35
R-507 5/8 ODF 7/8 ODF
1/2 ODF
D 6 3-1/2 to 6 N/A ECE-D-S 7/8 ODF
5/8 ODF
AA 1/2 1/3 to 1/2 EC-AA-V ECE-AA-V 1/4 ODF
1/2 ODF
A 1-1/2 3/4 to 1-1/2 EC-A-V ECE-A-V 3/8 ODF
W 3/8 ODF 1/2 ODF
B 3 1-1/2 to 3 EC-B-V ECE-B-V
R-22 Z 1/2 ODF 5/8 ODF
R-407C V X100 3/8 ODF 1/2 ODF 1/4 ODF
R-422D C 5 3 to 5 EC-C-V ECE-C-V X35 1/2 ODF 5/8 ODF
5/8 ODF 7/8 ODF
1/2 ODF
D 8 5 to 8 N/A ECE-D-V 7/8 ODF
5/8 ODF
AA 1/2 1/3 to 1/2 EC-AA-Z ECE-AA-Z 1/4 ODF
1/2 ODF
A 1-1/2 3/4 to 1-1/2 EC-A-Z ECE-A-Z 3/8 ODF
3/8 ODF 1/2 ODF
B 3 1-1/2 to 3 EC-B-Z ECE-B-Z
1/2 ODF 5/8 ODF
3/8 ODF 1/2 ODF
R-410A Z C 5 3 to 5 EC-C-Z ECE-C-Z X200 1/2 ODF 5/8 ODF 1/4 ODF
5/8 ODF 7/8 ODF
1/2 ODF
D 8 5 to 8 N/A ECE-D-Z 7/8 ODF
5/8 ODF
N/A 12-1/2 8 to 12-1/2 N/A ECE-12-1/2-Z 7/8 ODF
5/8 ODF
N/A 15 12-1/2 to 15 N/A ECE-15-Z 1-1/8 ODF
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 7

EC(E) Series
Dimensions
ECE-AA, -A, -B, -C, -D Fitting Size A B C D E F G
2.69” 2.17” 2.20” 3.36” 1.71”
1/4 — —
68 mm 55 mm 56 mm 63 mm 63 mm
60°
2.42” 2.17” 3.36”
3/8 — — — —
61 mm 55 mm 63 mm
2.35” 2.51” 2.17” 1.83” 3.36”
1/2 — —
60 mm 64 mm 55 mm 46 mm 63 mm
2.35” 2.51” 2.17” 1.83” 3.36”
5/8 — —
60 mm 64 mm 55 mm 46 mm 63 mm
G 2.51” 1.83” 3.36”
7/8 — — — —
3/8 ODF Inlet Strainer 64 mm 46 mm 63 mm
P/N 0877-003
1/2 ODF Inlet Strainer
P/N 0877-004 1.93”
49 mm
5/8 ODF Inlet Strainer
P/N 0877-005 Replacement Elements
Refrigerant
Element
Designation
KT-46-VW
V
F KT-46-VX100
J KT-46-JW
E KT-46-SZ
C D S KT-46-SW
KT-46-SX35
Z KT-46-ZX200
A B

ECE-12-1/2-Z and ECE-15-Z Only Fitting Size A B C D E F G


2.36” 3.79” 1.90”
1/4 — — — — 60 mm 96 mm 48 mm
30°
2.48” 2.30” 3.79”
5/8 — — — —
63 mm 58 mm 96 mm
G 2.51” 1.83” 3.79”
60° 7/8 — — — —
64 mm 46 mm 96 mm
2.51” 1.83” 3.79”
1-1/8 — — — —
64 mm 46 mm 96 mm

1.93”
49 mm
Replacement Elements
Refrigerant
Element
Designation

Z KT-46-5-ZX200*

F * For ECE-12-1/2-Z and ECE-15-Z only.

E
C
D

A B
Page 8 / Catalog E-1, Thermostatic & Automatic Expansion Valves

SC(E) Series
The SC(E) series brass body expansion valve incorporates a 90° elbow inlet with
a removable strainer that may be replaced or cleaned without removing the valve
from the system, and is an ideal choice for commerical refrigeration and super-
market applications.

Applications Features and Benefits


■■ Supermarket Cases ■■ Balanced port design
■■ Self-contained Cases ■■ Removable power element
■■ Walk-in Coolers/Freezers ■■ 60" capillary tube
■■ Ice Machines ■■ Removable inlet strainer – 100 mesh
■■ Salad Bars ■■ Field adjustable superheat
■■ Transport Refrigeration ■■ 1/4" ODF external equalizer
■■ “W”, “Z” or MOP “X” charges available
■■ Weight: 1.0 lbs / 0.45 kg
Specifications
Capacity Range Valve Description Connection - (Inches) External
Nominal
Refrigerant Orifice of Valve to Rainbow Equalizer
Refrigerant Capacity Internally Externally
Designation Designation be Replaced Charges™ Inlet Outlet Connection
(Tons) Equalized Equalized
(Tons) (Inches)
AA 1/4 1/6 to 1/4 SCE-AA-J
R-12
A 1 1/2 to 1 SCE-A-J
R-134a W
J B 2 1 to 2 N/A SCE-B-J 3/8 ODF 1/2 ODF 1/4 ODF
R-401A X60
C 3 2 to 3 SCE-C-J
R-401B
D 5 3 to 5 SCE-D-J
AAA 1/6 1/8 to 1/6 SCE-AAA-S
R-402A
AA 1/4 1/6 to 1/4 SCE-AA-S W
R-402B
A 1 1/2 to 1 SCE-A-S Z
R-404A S N/A 3/8 ODF 1/2 ODF 1/4 ODF
B 2 1 to 2 SCE-B-S X110
R-502
C 3-1/2 2 to 3-1/2 SCE-C-S X35
R-507
D 6 3-1/2 to 6 SCE-D-S
AAA 1/3 1/6 to 1/3 SCE-AAA-V
AA 1/2 1/3 to 1/2 SCE-AA-V W
R-22
A 1-1/2 3/4 to 1-1/2 SCE-A-V Z
R-407C V N/A 3/8 ODF 1/2 ODF 1/4 ODF
B 3 1-1/2 to 3 SCE-B-V X110
R-422D
C 5 3 to 5 SCE-C-V X35
D 8 5 to 8 SCE-D-V

Dimensions
60°

Removable Strainer
1.83” P/N 10198-000
46 mm

1.93”
49 mm

Replacement Elements
Refrigerant
3.36” Element
85 mm Designation
2.17” 2.20” KT-46-VW
1.83” V
55 mm 56 mm KT-46-VX100
46 mm
J KT-46-JW
0.59”
15 mm KT-46-SZ
1.29” 1.35” S KT-46-SW
33 mm 34 mm KT-46-SX35
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 9

C Series Interchangeable Valve


The C series replaceable element style valves are
designed for small refrigeration systems, such as
refrigerated cases, coolers, and freezers. The externally
equalized versions of these valves are ideal for air
conditioning and refrigeration systems. C valves are
balanced ported, engineered specifically for systems
with a wide range of operating conditions and may be
applied on bi-directional applications.
C valves are supplied as 2 individual component parts:
the thermostatic element, and the valve body. The
interchangeable nature of the C family makes it ideal
for reducing inventory, while increasing valve options
— so, the right valve is always on hand.
Body Features
C brass body type valves feature traditional knife
edge, metal-to-metal thermostatic element to valve
body construction, which ensures a leak-proof joint.
Selective Charges
The selective thermostatic charges are specifically designed for low temperature,
medium temperature, and air conditioning applications. The elements are manu-
factured with a large flat diaphragm to reduce diaphragm stresses and provide
precise control. And, because C valve bodies and thermostatic elements are sup-
plied as independent components, the installer is able to select the best possible
thermostatic charge for the application.
Internal Port Design
Refrigerant flow through the valve port opposes the pin movement in all type C
valves. This provides improved stability at light loads, when the pin modulates to
a position close to the port. Additionally, charge migration, is reduced or elimi-
nated by the C valve design. By engineering the liquid flow to enter through the
top of the valve body, the liquid refrigerant warms the thermostatic element and
minimizes the potential for charge migration.

Applications Features and Benefits


■■ Small Refrigeration Systems ■■ Balanced port design
■■ Air Conditioning Systems ■■ Removable power element
■■ Heat Pump Systems ■■ Inlet strainer – 100 mesh
■■ Freezers ■■ 60” capillary tube
■■ Walk-in Coolers ■■ Field adjustable superheat
■■ Refrigerated Cases ■■ 1/4” SAE external equalizer
■■ Weight: 1.0 lbs / 0.45 kg
Page 10 / Catalog E-1, Thermostatic & Automatic Expansion Valves

C Series Interchangeable Valve


Selecting Components
■■ Body
C EC SC
SAE ODF ODF
(Internally (Internally (Internally
Equalized) Equalized) Equalized)

CE ECE SCE
SAE ODF ODF
(Externally (Externally (Externally
Equalized) Equalized) Equalized)

Capacities
Nominal Capacity - Tons
(Capacity Range of Valve to be Replaced - Tons) Orifice Available
R-22 Designation Valve Body
R-401A R-402A Letter Code Configurations*
R-12 R-407C R-134a R-404A R-410A R-502 R-507
R-401B R-402B
R-422D
C - AA - 1/4 X 1/2 SAE
CE - AA - 1/4 X 1/2 X 1/4 SAE
1/4 1/2 1/4 1/4 1/4 1/4 1/2 1/4 1/4 EC - AA - 3/8 X 1/2 ODF
AA
(1/6 to 1/4) (1/3 to 1/2) (1/6 to 1/4) (1/6 to 1/4) (1/6 to 1/4) (1/6 to 1/4) (1/3 to 1/2) (1/6 to 1/4) (1/6 to 1/4) ECE - AA - 3/8 X 1/2 X 1/4 ODF
SC - AA - 3/8 X 1/2 ODF
SCE - AA - 3/8 X 1/2 X 1/4 ODF
C - A - 1/4 X 1/2 SAE
CE - A - 1/4 X 1/2 X 1/4 SAE
1 1-1/2 1 1 1 1 1-1/2 1 1 EC - A - 3/8 X 1/2 ODF
A
(1/2 to 1) (3/4 to 1-1/2) (1/2 to 1) (1/2 to 1) (1/2 to 1) (1/2 to 1) (3/4 to 1-1/2) (1/2 to 1) (1/2 to 1) ECE - A - 3/8 X 1/2 X 1/4 ODF
SC - A - 3/8 X 1/2 ODF
SCE - A - 3/8 X 1/2 X 1/4 ODF
CE - B - 1/4 X 1/2 X 1/4 SAE
2 3 2 2 2 2 3 2 2
B ECE - B - 3/8 X 1/2 X 1/4 ODF
(1 to 2) (1-1/2 to 3) (1 to 2) (1 to 2) (1 to 2) (1 to 2) (1-1/2 to 3) (1 to 2) (1 to 2)
SCE - B - 3/8 X 1/2 X 1/4 ODF
CE - C - 1/4 X 1/2 X 1/4 SAE
3 5 3 3 3-1/2 3-1/2 5 3-1/2 3-1/2
C ECE - C - 3/8 X 1/2 X 1/4 ODF
(2 to 3) (3 to 5) (2 to 3) (2 to 3) (2 to 3-1/2) (2 to 3-1/2) (3 to 5) (2 to 3-1/2) (2 to 3-1/2)
SCE - C - 3/8 X 1/2 X 1/4 ODF
5 8 5 5 6 6 8 6 6
D ECE - D - 3/8 X 1/2 X 1/4 ODF
(3 to 5) (5 to 8) (3 to 5) (3 to 5) (3-1/2 to 6) (3-1/2 to 6) (5 to 8) (3-1/2 to 6) (3-1/2 to 6)
*See Pages 5 through 8 for Valve Assembly Dimensions.

Body Nomenclature (Example)

CE – A – 3/8 x 1/2 x 1/4 SAE


Valve Orifice Connection Size and Style
Model Designation
Inlet x Outlet x External Equalizer
Connection Sizes
and Style
C, EC, SC AA
Internally A
Equalized B
CE, ECE, SCE C
Externally D
Equalized See capacity
table above for
more details.
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 11

C Series Interchangeable Valve


■■ Element **Application Factors:
1. The Type “X” thermostatic charges have
Capillary Tube Length
essentially the same characteristics as
Element Label (standard = 5 ft. / 1.5 m) the conventional Z cross charges with one
exception: they produce a pressure limit or
O
MOP. The “X” charges are not intended as
Bulb
,M

replacements for the Z charges - they should


ON

KT-46-VW
GT

MADE IN U.S.A.
FIN • WASHIN

Date Code Label only be used where a definite pressure limit is


R-22

DATE
(by week and year of manufacture)
NNI

2012
required to prevent motor overloading.
HA
ER

46
RK

2. All air conditioning and heat pump charges


A

VW
are intended for use with externally equal-
ized valves.
3. For dual temperature applications, use the
Element Nomenclature (Example) “W” charge.
4. The “W” charge may be used on applications
KT – 46 – V W down to -30°F (-34°C) on R-22, R-404A and
R-507.
5. R-410A elements for use with ECE only.
Element ✝Charge Type
Abbreviation Size Refrigerant Thermostatic
for “Kit” Code Q Charge “W” (all-purpose) liquid charge maintains nearly
Number flat superheat control over a -10°F to +60°F
(-23°C to +15°C) evaporator temperature
Q While many new refrigerants and refrigerant blends have a unique letter code, many use the same thermostatic element as the
traditional refrigerant they replace. Refer to the table below to select the correct thermostatic element.
range.
“Z” (low temperature) charge provides fast
pulldown benefits like a gas charge with the
Recommended Thermostatic Valve Charges** non-migrating benefits of a liquid charge;
usable over a -40°F to 0°F (-40°C to -18°C)
Refrigerants evaporator temperature range.
Applicable Evaporator
Application 22 12 502 “X” (damped response) gas charge provides a
Temperature Range 410A
407C 134a 404A pressure limiting (MOP) charge with anti-
hunt characteristics over a -40°F to +60°F
Low Temperature
Refrigeration
-40°F to 0°F VZ – SZ – (-40°C to +15°C) evaporator temperature
range.
Commercial Refrigeration -30°F to +60°F VW JW SW – Notes: M.O.P. not available on “W” or “Z” charge.
1. Maximum operational pressure 500 psig (35
Low Temperature bar) high side and 275 psig (19 bar) low side.
-40°F to +0°F VX35 – SX35 –
Pressure Limiting
2. Maximum storage temperature 130°F (55°C).
Commercial 3. Consult Parker for pressure and temperature
-10°F to +60°F VX100 JX60 – ZX200
Pressure Limiting exceptions.
4. Do not use “W” or “Z” liquid charges in appli-
Air Conditioning +30°F to +60°F VX100 JX60 – ZX200
cations where bulb temperatures can exceed
130°F (55°C).
For these applications use type “X” MOP gas
charge only.
Rainbow Charge Refrigerant Color Code
Refrigerant Designation R-12 - yellow
R-134a, R-401A (MP39), R-134a - light blue
J R-22 - green
R-401B (MP66), R-12
V R-407C (AC9000), R-22 R-402A - light brown (sand)
R-125, R-404A (HP62), R-402B - olive
S R-402A (HP80), R-402B R-404A - orange
(HP81), R-507 (AZ50) R-407C - medium brown
Z R-410A (AZ20) R-410A - rose
R-502 - purple
R-507 - teal
Page 12 / Catalog E-1, Thermostatic & Automatic Expansion Valves

H Series and HC Series


The H series balanced port valve is designed specifically for air conditioning and
heat pumps used in both air or water source systems. It offers features such as bleed
ports and a variety of connection styles for the inlet, outlet and external equalizer.

The HC series adds a built-in 5 ton check valve for R-22, R-407C and R-410A
heat pump applications with either factory set or field adjustable superheat.

Applications Features and Benefits


■■ Air Conditioning Systems ■■ Stainless steel power element
■■ Heat Pump Systems ■■ Bleed ports available
■■ Bi-flow (package) Heat Pump Systems ■■ Bi-directional metering available
■■ Weight: 10.7 oz. (.30 kg)
■■ Factory set or field adjustable
■■ Low pressure drop internal check valve

Specifications
Valve Description Bleed Port Connections - (Inches)
Nominal
Refrigerant Rainbow for Off Cycle
Refrigerant Capacity
Designation Internally Externally ChargesTM Operation
(Tons) Inlet Outlet
Equalized Equalized (Optional)

1-1/2 HA 1-1/2V HAE 1-1/2V 1/4, 3/8, 1/2 3/8, 1/2, 5/8
3 HA 3V HAE 3V X100 B & 5/8 ODF & 7/8 ODF
5 HA 5V HAE 5V flo-rater flo-rater
R-22
V models with internal check valves - “C” designation
R-407C
1-1/2 HCA 1-1/2V HCAE 1-1/2V 1/4, 3/8, 1/2 3/8, 1/2, 5/8
3 HCA 3V HCAE 3V X100 B & 5/8 ODF & 7/8 ODF
5 HCA 5V HCAE 5V flo-rater flo-rater
1-1/2 HA 1-1/2Z HAE 1-1/2Z 1/4, 3/8, 1/2 3/8, 1/2, 5/8
3 HA 3Z HAE 3Z X200 B & 5/8 ODF & 7/8 ODF
5 HA 5Z HAE 5Z flo-rater flo-rater
specific models with internal check valves - “C” designation
R-410A Z
1-1/2 HCA 1-1/2Z HCAE 1-1/2Z
1/4, 3/8, 1/2 3/8, 1/2, 5/8
2 HCA 2Z HCAE 2Z
X200 B & 5/8 ODF & 7/8 ODF
3 HCA 3Z HCAE 3Z
flo-rater flo-rater
5 HCA 5Z HCAE 5Z
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 13

H Series and HC Series


Dimensions
Connections ODF
0.093” / 2.4 mm OD
Capillary Tube
1.50”
38 mm Fitting Size
A B
Inlet/Outlet
1.46” 1.46”
1/4
37 mm 37 mm
Outlet 1.69” 1.69”
3/8
43 mm 43 mm
2.47” 1.46 1.46
Inlet 1/2
63 mm 37 mm 37 mm
1.54” 1.57” 1.57”
39 mm Optional 1.16” 5/8
Inlet Screen 40 mm 40 mm
29 mm
Available 2.07”
7/8 —
53 mm
A B
3.00”
76 mm

0.75”
19 mm
OD

Dimensions
Connections – flo-rater
Inlet 3/4” – 20
Outlet 3/4” – 20
0.093” / 2.4 mm OD
Capillary Tube
1.50”
38 mm

Inlet
1.60” Check Valve Section
41 mm 1.25”
Outlet 32 mm Allows reverse flow in
heating mode.

1.60”
3.00” 41 mm
76 mm

0.75”
19 mm
OD
Page 14 / Catalog E-1, Thermostatic & Automatic Expansion Valves

EBSE Series
The EBSE series valve is a brass bar body valve and features a balanced port
construction and extended ODF connections. The thermostatic element is
replaceable. The balanced port construction makes this valve ideally suited for air
conditioning and commercial refrigeration applications which operate over widely
varying conditions.

Applications Features and Benefits


■■ Air Conditioning ■■ Balanced port design
■■ Commercial Refrigeration ■■ Removable power element
■■ Field adjustable superheat
■■ 1/4” sweat external equalizer

Specifications
Nominal Standard Tubing Connection - (Inches) External Equalizer
Refrigerant Valve Rainbow
Refrigerant Capacity Length Connection
Designation Description Charges™
(Tons) Feet (m) Inlet Outlet (Inches)
R-12 5 EBSE-5-J
5/8 ODF 7/8 ODF
R-134a 7 EBSE-7-J 5
J W 1/4 ODF
R-401A 9 EBSE-9-J (1.5) 1-1/8 ODF
7/8 ODF
R-401B 12 EBSE-12-J 1-3/8 ODF
R-402A 6 EBSE-6-S
R-402B W 5/8 ODF 7/8 ODF
7-1/2 EBSE-7-1/2-S 5
R-404A S Z 1/4 ODF
10 EBSE-10-S (1.5) 1-1/8 ODF
R-502 X35 7/8 ODF
R-507 13 EBSE-13-S 1-3/8 ODF
8 EBSE-8-V
R-22 5/8 ODF 7/8 ODF
11 EBSE-11-V W 5
R-407C V 1/4 ODF
15 EBSE-15-V X100 (1.5) 1-1/8 ODF
R-422D 7/8 ODF
20 EBSE-20-V 1-3/8 ODF

Dimensions
30° Fitting Size A B C
1/4 ODF External 2.46” .50”
5/8 —
Equalizer Connection 62 mm 13 mm
2.46” 2.53” .75”
7/8
62 mm 64 mm 19 mm
2.53” .81”
1-1/8 —
64 mm 21 mm
3.04 .97”
1-3/8 —
77 mm 25 mm

2.31”
59 mm

1.81”
46 mm

Replacement Elements
C 3.5”
89 mm Refrigerant
Element
C Designation
3.41”
87 mm KT-83-VW
2.82” V
72 mm KT-83-VX100
J KT-83-JW
0.50”
13 mm KT-83-SW
S KT-83-SZ
A B KT-83-SX35
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 15

OE Series
The OE series valve utilizes balanced port construction to provide optimum opera-
tion on medium to large tonnage air conditioning and refrigeration systems. Two
brass body styles with copper ODF connections and a removable thermostatic
power element provide the stability and control required in a variety of applica-
tions, especially where there are wide changes in load conditions. Body Style 1 has
an R-22 nominal capacity up to 30 tons, while Body Style 2 extends the capacity
range to 70 tons.

Applications Features and Benefits


■■ Air Conditioning ■■ Balanced port design
■■ Process Chillers ■■ Removable power element
■■ Commercial Refrigeration ■■ Field adjustable superheat
■■ 1/4” sweat external equalizer
■■ 60” capillary tube

Specifications
Nominal Standard Tubing Connection - (Inches) External Equalizer
Refrigerant Valve Rainbow
Refrigerant Capacity Length Connection
Designation Description Charges™ Inlet Outlet
(Tons) Feet (m) (Inches)
9 OE-9-J 1-1/8 ODF
7/8 ODF
R-12 12 OE-12-J
R-134a 16 OE-16-J 5
J W 1/4 ODF
R-401A 23 OE-23-J (1.5) 1-3/8 ODF
1-1/8 ODF
R-401B 32 OE-32-J
40 OE-40-J
9 OE-9-S 1-1/8 ODF
R-402A 7/8 ODF
12 OE-12-S
R-402B W
21 OE-21-S 5
R-404A S Z 1/4 ODF
30 OE-30-S (1.5) 1-3/8 ODF
R-502 X35 1-1/8 ODF
35 OE-35-S
R-507
45 OE-45-S
15 OE-15-V 1-1/8 ODF
7/8 ODF
20 OE-20-V
R-22
30 OE-30-V W 5
R-407C V 1/4 ODF
40 OE-40-V X110 (1.5) 1-3/8 ODF
R-422D 1-1/8 ODF
55 OE-55-V
70 OE-70-V
20 OE-20-Z
7/8 ODF
25 OE-25-Z
5
R-410A Z 35 OE-35-Z X200 1-3/8 ODF 1/4 ODF
(1.5)
50 OE-50-Z 1-1/8 ODF
60 OE-60-Z
Page 16 / Catalog E-1, Thermostatic & Automatic Expansion Valves

OE Series
Dimensions – Inches

Type OE with Number 83 & 85 Element Type OE with Number 33 & 85-3 Element
1/4 ODF External 1/4 ODF External
Equalizer Connection Equalizer Connection

1.40 / 36 mm 1.59” / 40 mm
1/4 ODF 1/4 ODF

2.31” 2.75”
59 mm 70 mm

1.70” 1.93”
43 mm 2.43” 49 mm 2.90”
62 mm 74 mm

C
C
3.5” 3.5”
89 mm C 89 mm
C
4.14” 5.52”
105 mm 140 mm

0.50” 0.50”
13 mm 13 mm

A B
A B

Fitting Size
A B C
Straight Thru ODF Solder
Fitting Size 2.09” 0.78”
A B C 7/8 —
Straight Thru ODF Solder 53 mm 20 mm
2.09” 0.75” 2.69” 0.91”
7/8 — 1-1/8 —
53 mm 19 mm 68 mm 23 mm
2.21” 2.23” 0.91” 2.84” 0.97”
1-1/8 1-3/8 —
56 mm 57 mm 23 mm 72 mm 25 mm
2.39” 0.97” 3.12” 1.09”
1-3/8 — 1-5/8 —
61 mm 25 mm 79 mm 28 mm

Replacement Elements
Refrigerant
Element
Designation
KT-83-VW KT-33-VW
V
KT-83-VX100 KT-33-VX100

Z KT-85-ZX200 KT-85-3-ZX200

KT-83-SW KT-33-SW
S KT-83-SZ KT-33-SZ
KT-83-SX35 KT-33-SX35

J KT-83-JW KT-33-JW
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 17

Capacity Tables
R-22 Capacities in Tons (R-407C Refrigerant & Liquid Temperature Correction Factor below)
Nominal Evaporator Temperature°F
Capacity (Tons) 40°F 20°F 0°F
Valve Type
or Orifice Pressure Drop (PSI)
Designation 75 100 125 150 175 200 225 250 75 100 125 150 175 200 225 250 75 100 125 150 175 200 225 250
N 1 0.87 1.0 1.1 1.2 1.3 1.4 1.5 1.6 0.85 0.98 1.1 1.2 1.3 1.4 1.5 1.5 0.75 0.87 0.97 1.1 1.2 1.2 1.3 1.4
N 3 2.6 3.0 3.4 3.7 4.0 4.3 4.5 4.7 2.5 2.9 3.3 3.6 3.9 4.1 4.4 4.6 2.3 2.6 2.9 3.2 3.5 3.7 3.9 4.1
H(E), HC(E) 1-1/2 1.3 1.5 1.7 1.8 2.0 2.1 2.3 2.4 1.3 1.5 1.6 1.8 1.9 2.1 2.2 2.3 1.1 1.3 1.5 1.6 1.8 1.9 2.0 2.1
H(E), HC(E) 3 2.6 3.0 3.4 3.7 4.0 4.2 4.4 4.5 2.6 2.9 3.3 3.6 3.9 4.2 4.3 4.4 2.3 2.6 3.0 3.2 3.5 3.7 3.8 3.9
H(E), HC(E) 5 4.3 5.0 5.6 6.1 6.6 7.1 7.2 7.3 4.2 4.9 5.5 6.0 6.5 6.9 7.0 7.1 3.8 4.4 4.9 5.4 5.8 6.2 6.3 6.4
SCE AAA 0.30 0.35 0.39 0.43 0.46 0.50 0.53 0.55 0.30 0.34 0.38 0.42 0.45 0.48 0.51 0.54 0.26 0.30 0.33 0.37 0.40 0.42 0.45 0.47
C(E), EC(E), SCE AA 0.52 0.60 0.67 0.73 0.79 0.85 0.90 0.95 0.51 0.58 0.65 0.72 0.77 0.83 0.88 0.92 0.44 0.51 0.57 0.63 0.68 0.72 0.77 0.81
C(E), EC(E), SCE A 1.5 1.8 2.0 2.1 2.3 2.5 2.6 2.8 1.5 1.7 1.9 2.1 2.3 2.4 2.6 2.7 1.3 1.5 1.7 1.9 2.0 2.2 2.3 2.4
C(E), EC(E), SCE B 2.8 3.2 3.6 3.9 4.2 4.5 4.8 5.1 2.7 3.1 3.5 3.8 4.1 4.4 4.7 4.9 2.4 2.8 3.1 3.4 3.7 3.9 4.2 4.4
C(E), EC(E), SCE C 4.3 5.0 5.6 6.1 6.6 7.1 7.5 7.9 4.2 4.9 5.5 6.0 6.5 6.9 7.3 7.7 3.8 4.4 4.9 5.3 5.8 6.2 6.5 6.9
C(E), EC(E), SCE D 6.9 8.0 9.0 9.8 10.6 11.3 12.0 12.7 6.8 7.8 8.7 9.6 10.3 11.0 11.7 12.3 6.0 7.0 7.8 8.5 9.2 9.9 10.5 11.0
EBSE 8 7.4 8.5 9.5 10.4 11.2 12.0 12.8 13.4 6.8 7.9 8.8 9.6 10.4 11.1 11.8 12.4 5.7 6.5 7.3 8.0 8.6 9.2 9.8 10.3
EBSE 11 10.0 11.5 12.9 14.1 15.2 16.3 17.3 18.2 9.2 10.7 11.9 13.0 14.1 15.1 16.0 16.8 7.6 8.8 9.9 10.8 11.7 12.5 13.2 14.0
EBSE 15 13.4 15.5 17.3 18.9 20.5 21.9 23.2 24.4 12.6 14.6 16.3 17.8 19.3 20.6 21.9 23.0 9.4 10.9 12.2 13.3 14.4 15.4 16.3 17.2
EBSE 20 19.3 22.3 25.0 27.4 29.5 31.6 33.5 35.3 17.7 20.4 22.8 25.0 27.0 28.9 30.6 32.3 13.1 15.1 16.9 18.5 20.0 21.4 22.7 23.9
OE 15 13.0 15.0 16.8 18.4 19.8 21.2 22.5 23.7 12.0 13.9 15.5 17.0 18.4 19.6 20.8 22.0 10.1 11.7 13.0 14.3 15.4 16.5 17.5 18.4
OE 20 19.2 22.2 24.8 27.2 29.4 31.4 33.3 35.1 17.8 20.6 23.0 25.2 27.2 29.1 30.8 32.5 14.9 17.2 19.3 21.1 22.8 24.4 25.9 27.3
OE 30 26.4 30.5 34.1 37.4 40.4 43.1 45.8 48.2 24.5 28.2 31.6 34.6 37.4 39.9 42.4 44.7 20.5 23.7 26.5 29.0 31.3 33.5 35.5 37.5
OE 40 34.9 40.3 45.1 49.4 53.3 57.0 60.5 63.7 33.7 38.9 43.5 47.6 51.5 55.0 58.3 61.5 24.8 28.6 32.0 35.1 37.9 40.5 42.9 45.3
OE 55 47.6 55.0 61.5 67.4 72.8 77.8 82.5 87.0 46.0 53.1 59.3 65.0 70.2 75.1 79.6 83.9 33.8 39.1 43.7 47.9 51.7 55.3 58.6 61.8
OE 70 63.2 73.0 81.6 89.4 96.6 103 110 115 61.0 70.5 78.8 86.3 93.2 99.6 106 111 44.9 51.9 58.0 63.5 68.6 73.3 77.8 82.0
These ratings are based on vapor free 100°F liquid refrigerant entering the expansion valve, and a maximum of 7°F change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F 0°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-22 1.57 1.45 1.34 1.23 1.12 1.00 0.88 0.76 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-407C
at a 40°F evaporator, 125 psi pressure drop across the TEV, and a 80°F liquid temperature entering the
R-407C 1.58 1.45 1.32 1.18 1.04 0.89 0.74 0.57 TEV = 3.58 (from rating chart) x 1.04 (CF liquid temperature) = 3.72 tons

R-22 Capacities in Kilowatts (R-407C Refrigerant & Liquid Temperature Correction Factor below)
Nominal Capacity Evaporator Temperature°C
(kW) 5°C -5°C -15°C
Valve Type
or Orifice Pressure Drop (BAR)
Designation 4 6 8 10 12 14 16 18 4 6 8 10 12 14 16 18 4 6 8 10 12 14 16 18
N 4 2.6 3.2 3.7 4.2 4.5 4.9 5.3 5.6 2.6 3.1 3.6 4.1 4.4 4.8 5.1 5.4 2.4 2.9 3.3 3.7 4.1 4.4 4.7 5.0
N 11 7.9 9.7 11.2 12.5 13.6 14.7 15.8 16.7 7.7 9.4 10.9 12.2 13.3 14.3 15.4 16.3 7.0 8.6 9.9 11.2 12.2 13.1 14.1 14.9
H(E), HC(E) 5 4.0 4.9 5.7 6.4 7.0 7.5 8.0 8.5 3.9 4.8 5.6 6.2 6.8 7.4 7.9 8.3 3.6 4.4 5.0 5.6 6.2 6.7 7.1 7.6
H(E), HC(E) 11 8.0 9.8 11.4 12.7 13.9 15.0 16.1 17.0 7.9 9.6 11.1 12.4 13.6 14.7 15.7 16.7 7.1 8.7 10.1 11.3 12.3 13.3 14.3 15.1
H(E), HC(E) 18 13.4 16.4 18.9 21.2 23.2 25.1 26.8 28.4 13.1 16.1 18.5 20.7 22.7 24.5 26.2 27.8 11.9 14.6 16.8 18.8 20.6 22.2 23.8 25.2
SCE AAA 0.92 1.1 1.3 1.5 1.6 1.7 1.8 2.0 0.90 1.1 1.3 1.4 1.6 1.7 1.8 1.9 0.81 0.99 1.1 1.3 1.4 1.5 1.6 1.7
C(E), EC(E), SCE AA 1.6 1.9 2.2 2.5 2.7 2.9 3.1 3.3 1.5 1.9 2.2 2.4 2.7 2.9 3.1 3.3 1.4 1.7 2.0 2.2 2.4 2.6 2.8 2.9
C(E), EC(E), SCE A 4.6 5.6 6.5 7.3 8.0 8.6 9.2 9.7 4.5 5.5 6.3 7.1 7.8 8.4 9.0 9.5 4.1 5.0 5.8 6.5 7.1 7.7 8.2 8.7
C(E), EC(E), SCE B 8.4 10.3 11.9 13.3 14.5 15.7 16.8 17.8 8.2 10.0 11.6 13.0 14.2 15.3 16.4 17.4 7.5 9.2 10.6 11.9 13.0 14.0 15.0 15.9
C(E), EC(E), SCE C 13.1 16.1 18.5 20.7 22.7 24.5 26.2 27.8 12.8 15.7 18.1 20.3 22.2 24.0 25.6 27.2 11.7 14.4 16.6 18.6 20.3 22.0 23.5 24.9
C(E), EC(E), SCE D 21.0 25.7 29.7 33.2 36.3 39.2 42.0 44.5 20.5 25.1 29.0 32.4 35.5 38.3 41.0 43.5 18.8 23.0 26.5 29.7 32.5 35.1 37.5 39.8
EBSE 28 22.4 27.4 31.6 35.4 38.7 41.8 44.7 47.4 20.9 25.5 29.5 33.0 36.1 39.0 41.7 44.2 17.9 22.0 25.3 28.3 31.0 33.5 35.8 38.0
EBSE 39 30.3 37.0 42.8 47.8 52.4 56.6 60.5 64.2 28.2 34.6 39.9 44.6 48.9 52.8 56.4 59.9 24.3 29.7 34.3 38.3 42.0 45.4 48.5 51.4
EBSE 53 40.6 49.8 57.5 64.2 70.4 76.0 81.3 86.2 38.5 47.1 54.4 60.9 66.7 72.0 77.0 81.6 30.9 37.8 43.6 48.8 53.5 57.7 61.7 65.5
EBSE 70 58.8 72.0 83.1 92.9 102 110 118 125 54.2 66.4 76.7 85.7 93.9 101 108 115 43.0 52.6 60.8 67.9 74.4 80.4 85.9 91.2
OE 53 39.5 48.3 55.8 62.4 68.3 73.8 78.9 83.7 36.8 45.1 52.0 58.2 63.7 68.9 73.6 78.1 31.9 39.1 45.1 50.5 55.3 59.7 63.8 67.7
OE 70 58.4 71.5 82.6 92.3 101 109 117 124 54.5 66.7 77.0 86.1 94.3 102 109 116 47.2 57.8 66.8 74.7 81.8 88.4 94.5 100
OE 105 80.2 98.3 113 127 139 150 160 170 74.8 91.6 106 118 130 140 150 159 64.9 79.5 91.8 103 112 121 130 138
OE 141 106 130 150 167 183 198 212 224 102 125 145 162 177 192 205 217 81.5 99.8 115 129 141 152 163 173
OE 193 144 177 204 228 250 270 289 306 140 171 198 221 242 261 279 296 111 136 157 176 193 208 222 236
OE 246 192 235 271 303 332 359 383 407 185 227 262 293 321 347 371 393 148 181 209 233 256 276 295 313
These ratings are based on vapor free 40°C liquid refrigerant entering the expansion valve, and a maximum of 4°C change in superheat.
These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
Liquid Temperature Entering TEV on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -15°C to 5°C since the variation in the actual factors across this range is insignificant.
Correction Factor
TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-407C
R-22 1.52 1.42 1.32 1.21 1.11 1.00 0.89 0.78 at a 5°C evaporator, 8 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV
R-407C 1.53 1.41 1.28 1.15 1.02 0.88 0.74 0.59 = 12.1 (from rating chart) x 1.02 (CF liquid temperature) = 12.3 kW
Page 18 / Catalog E-1, Thermostatic & Automatic Expansion Valves

Capacity Tables
R-134a Capacities in Tons (R-401A, R-409A Refrigerant & Liquid Temperature Correction Factor below)
Nominal Evaporator Temperature °F
Capacity (Tons) 40°F 20°F 0°F
Valve Type
or Orifice Pressure Drop (PSI)
Designation 40 60 80 100 120 140 160 180 40 60 80 100 120 140 160 180 40 60 80 100 120 140 160 180
N 1/2 0.59 0.72 0.83 0.93 1.0 1.1 1.2 1.3 0.56 0.69 0.79 0.89 0.98 1.1 1.1 1.2 0.49 0.61 0.70 0.78 0.85 0.92 0.99 1.1
N 2 1.8 2.2 2.5 2.8 3.1 3.3 3.5 3.8 1.7 2.1 2.4 2.7 2.9 3.1 3.4 3.6 1.5 1.8 2.1 2.3 2.6 2.8 3.0 3.1
C(E), EC(E), SCE AA 0.35 0.43 0.50 0.56 0.61 0.66 0.70 0.74 0.34 0.41 0.47 0.53 0.58 0.63 0.67 0.71 0.32 0.39 0.45 0.50 0.55 0.60 0.64 0.68
C(E), EC(E), SCE A 1.0 1.3 1.5 1.6 1.8 1.9 2.1 2.2 0.99 1.2 1.4 1.6 1.7 1.8 2.0 2.1 0.86 1.1 1.2 1.4 1.5 1.6 1.7 1.8
C(E), EC(E), SCE B 1.9 2.3 2.7 3.0 3.3 3.5 3.8 4.0 1.8 2.2 2.6 2.9 3.1 3.4 3.6 3.8 1.6 1.9 2.2 2.5 2.7 3.0 3.2 3.4
C(E), EC(E), SCE C 3.0 3.6 4.2 4.7 5.1 5.5 5.9 6.3 2.8 3.5 4.0 4.5 4.9 5.3 5.6 6.0 2.5 3.0 3.5 3.9 4.3 4.6 4.9 5.2
C(E), EC(E), SCE D 4.7 5.8 6.7 7.5 8.2 8.8 9.4 10.0 4.5 5.5 6.4 7.1 7.8 8.4 9.0 9.6 3.9 4.8 5.6 6.2 6.8 7.4 7.9 8.4
EBSE 5 5.0 6.1 7.1 7.9 8.7 9.4 10.0 10.6 4.0 4.9 5.6 6.3 6.9 7.4 7.9 9.4 3.4 4.2 4.8 5.4 5.9 6.4 6.8 7.2
EBSE 7 6.9 8.4 9.7 10.9 11.9 12.9 13.8 14.6 5.5 6.7 7.7 8.6 9.5 10.2 10.9 11.6 4.7 5.8 6.6 7.4 8.1 8.8 9.4 10.0
EBSE 9 9.1 11.2 12.9 14.4 15.8 17.1 18.2 19.4 6.9 8.4 9.7 10.9 11.9 12.9 13.7 14.6 5.5 6.8 7.8 8.7 9.6 10.3 11.0 11.7
EBSE 12 13.1 16.0 18.5 20.7 22.6 24.4 26.1 27.7 9.9 12.1 14.0 15.6 17.1 18.5 19.7 20.9 7.7 9.5 10.9 12.2 13.4 14.5 15.4 16.4
OE 9 8.9 10.8 12.5 14.0 15.3 16.6 17.7 18.8 7.6 9.3 10.8 12.0 13.2 14.2 15.2 16.1 6.6 8.1 9.3 10.4 11.4 12.6 13.2 14.0
OE 12 11.5 14.1 16.3 18.2 19.9 21.5 23.0 24.4 9.9 12.1 14.0 15.6 17.1 18.5 19.8 21.0 8.6 10.5 12.1 13.6 14.9 16.0 17.1 18.2
OE 16 15.2 18.7 21.6 24.1 26.4 28.5 30.5 32.3 13.1 16.0 18.5 20.7 22.7 24.5 26.2 27.8 11.4 13.9 16.1 18.0 19.7 21.3 22.7 24.1
OE 23 22.6 27.7 32.0 35.8 39.2 42.3 45.2 48.0 21.2 25.9 29.9 33.5 36.7 39.6 42.3 44.9 17.5 21.4 24.7 27.6 30.3 32.7 34.9 37.1
OE 32 31.5 38.6 44.5 49.8 54.5 58.9 63.0 66.8 29.5 36.1 41.7 46.6 51.0 55.1 58.9 62.5 24.3 29.8 34.4 38.4 42.1 45.5 48.6 51.6
OE 40 39.3 48.2 55.6 62.2 68.1 73.6 78.7 83.5 36.8 45.1 52.1 58.2 63.8 68.9 73.6 78.1 30.4 37.2 43.0 48.0 52.6 56.9 60.8 64.5
These ratings are based on vapor free 100°F liquid refrigerant entering the expansion valve, and a maximum of 7°F change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F 0°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-134a 1.69 1.56 1.42 1.29 1.14 1.00 0.85 0.71 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-409A
at a 20°F evaporator, 120 psi pressure drop across the TEV, and a 80°F liquid temperature entering the
R-401A 1.75 1.62 1.49 1.36 1.23 1.09 0.95 0.81 TEV = 3.12 (from rating chart) x 1.19 (CF liquid temperature) = 3.72 tons
R-409A 1.65 1.54 1.42 1.31 1.19 1.06 0.94 0.81

R-134a Capacities in Kilowatts (R-401A, R-409A Refrigerant & Liquid Temperature Correction Factor below)
Nominal Evaporator Temperature °C
Capacity (kW) 5°C -5°C -15°C
Valve Type
or Orifice Pressure Drop (BAR)
Designation 2.5 4.0 5.5 7.0 8.5 10.0 11.5 13.0 2.5 4.0 5.5 7.0 8.5 10.0 11.5 13.0 2.5 4.0 5.5 7.0 8.5 10.0 11.5 13.0
N 3 1.9 2.4 2.9 3.2 3.6 3.9 4.1 4.4 1.9 2.3 2.7 3.1 3.4 3.7 4.0 4.2 1.7 2.1 2.5 2.8 3.1 3.3 3.6 3.8
N 7 5.8 7.3 8.6 9.7 10.7 11.5 12.4 13.2 5.5 7.0 8.2 9.3 10.2 11.1 11.9 12.7 5.0 6.3 7.4 8.3 9.2 9.9 10.7 11.3
C(E), EC(E), SCE AA 1.2 1.5 1.7 1.9 2.1 2.3 2.5 2.6 1.1 1.4 1.6 1.8 2.0 2.2 2.4 2.5 1.1 1.3 1.6 1.8 1.9 2.1 2.3 2.4
C(E), EC(E), SCE A 3.4 4.3 5.0 5.6 6.2 6.7 7.2 7.7 3.2 4.1 4.8 5.4 6.0 6.5 6.9 7.4 2.9 3.7 4.3 4.9 5.4 5.8 6.2 6.6
C(E), EC(E), SCE B 6.2 7.8 9.2 10.3 11.4 12.3 13.2 14.1 5.9 7.5 8.8 9.9 10.9 11.8 12.7 13.5 5.3 6.7 7.9 8.9 9.8 10.6 11.4 12.1
C(E), EC(E), SCE C 9.6 12.2 14.3 16.1 17.8 19.3 20.7 22.0 9.2 11.7 13.7 15.5 17.0 18.5 19.8 21.1 8.3 10.5 12.3 13.9 15.3 16.6 17.8 18.9
C(E), EC(E), SCE D 15.4 19.5 22.9 25.8 28.4 30.8 33.1 35.2 14.8 18.7 21.9 24.7 27.3 29.6 31.7 33.7 13.3 16.8 19.7 22.2 24.5 26.5 28.5 30.3
EBSE 18 16.5 20.8 24.4 27.6 30.4 33.0 35.3 37.6 13.4 17.0 19.9 22.5 24.7 26.8 28.8 30.6 11.6 14.6 17.1 19.3 21.3 23.1 24.8 26.3
EBSE 25 22.7 28.7 33.7 38.0 41.9 45.4 48.7 51.8 18.5 23.4 27.4 30.9 34.1 37.0 39.7 42.2 15.9 20.1 23.6 26.6 29.4 31.9 34.2 36.3
EBSE 32 30.2 38.2 44.7 50.5 55.6 60.3 64.7 68.8 23.5 29.7 34.9 39.3 43.3 47.0 50.4 53.6 19.1 24.1 28.3 31.9 35.2 38.2 40.9 43.5
EBSE 42 43.2 54.6 64.1 72.3 79.6 86.4 92.6 98.5 33.7 42.7 50.0 56.4 62.2 67.4 72.3 76.9 26.9 34.0 39.9 45.0 49.6 53.8 57.7 61.4
OE 32 29.1 36.8 43.2 48.7 53.7 58.2 62.4 66.4 25.4 32.2 37.7 42.6 46.9 50.9 54.6 58.0 22.3 28.3 33.1 37.4 41.2 44.7 47.9 50.9
OE 42 37.8 47.9 56.1 63.3 69.8 75.7 81.2 86.3 33.1 41.8 49.0 55.3 61.0 66.1 70.9 75.4 29.0 36.7 43.1 48.6 53.5 58.1 62.3 66.2
OE 56 50.1 63.4 74.4 83.9 92.4 100 108 114 43.8 55.4 65.0 73.3 80.8 87.6 93.9 100 38.5 48.7 57.1 64.4 70.9 76.9 82.5 87.7
OE 81 74.1 93.7 110 124 137 148 159 169 69.8 88.3 104 117 129 140 150 159 60.0 75.9 89.0 100 111 120 129 137
OE 110 103 130 153 172 190 206 221 235 97.2 123 144 163 179 194 208 222 83.4 106 124 140 154 167 179 190
OE 140 129 163 191 216 238 258 276 294 121 154 180 203 224 243 260 277 104 132 155 175 192 209 224 238
These ratings are based on vapor free 40°C liquid refrigerant entering the expansion valve, and a maximum of 4°C change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -15°C to 5°C since the variation in the actual factors across this range is insignificant.
Correction Factor
R-134a 1.64 1.52 1.39 1.26 1.13 1.00 0.87 0.73 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-409A
at a -5°C evaporator, 8.5 bar pressure drop across the TEV, and a 30°C liquid temperature entering the
R-401A 1.70 1.59 1.46 1.34 1.22 1.09 0.96 0.83 TEV = 11.2 (from rating chart) x 1.18 (CF liquid temperature) = 13.2 kW
R-409A 1.61 1.50 1.40 1.29 1.18 1.07 0.95 0.83
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 19

Capacity Tables
R-404A Capacities in Tons (R-507 Refrigerant & Liquid Temperature Correction Factor below)
Nominal Evaporator Temperature °F
Capacity (Tons) 40°F 20°F
Valve Type
or Orifice Pressure Drop (PSI)
Designation 75 100 125 150 175 200 225 250 75 100 125 150 175 200 225 250
N 1/2 0.57 0.66 0.74 0.81 0.87 0.94 1.0 1.1 0.54 0.63 0.70 0.77 0.83 0.89 0.94 1.0
N 2 1.7 2.0 2.2 2.4 2.6 2.8 3.0 3.1 1.6 1.9 2.1 2.3 2.5 2.7 2.8 3.0
SCE AAA 0.20 0.23 0.26 0.28 0.30 0.33 0.34 0.36 0.19 0.22 0.24 0.27 0.29 0.31 0.33 0.34
C(E), EC(E), SCE AA 0.34 0.39 0.44 0.48 0.52 0.56 0.59 0.62 0.32 0.37 0.42 0.46 0.49 0.53 0.56 0.59
C(E), EC(E), SCE A 1.0 1.2 1.3 1.4 1.5 1.6 1.7 1.8 0.95 1.1 1.2 1.3 1.5 1.6 1.7 1.7
C(E), EC(E), SCE B 1.8 2.1 2.4 2.6 2.8 3.0 3.2 3.3 1.7 2.0 2.2 2.5 2.7 2.8 3.0 3.2
C(E), EC(E), SCE C 2.9 3.3 3.7 4.1 4.4 4.7 5.0 5.2 2.7 3.1 3.5 3.8 4.2 4.4 4.7 5.0
C(E), EC(E), SCE D 4.6 5.3 5.9 6.5 7.0 7.5 7.9 8.4 4.3 5.0 5.6 6.1 6.6 7.1 7.5 7.9
EBSE 6 4.9 5.7 6.4 7.0 7.6 8.1 8.6 9.0 4.4 5.0 5.6 6.2 6.7 7.1 7.5 8.0
EBSE 7-1/2 6.7 7.7 8.7 9.5 10.2 11.0 11.6 12.2 5.9 6.8 7.6 8.4 9.0 9.7 10.2 10.8
EBSE 10 8.3 9.5 10.7 11.7 12.6 13.5 14.3 15.1 7.5 8.6 9.6 10.5 11.4 12.2 12.9 13.6
EBSE 13 11.8 13.6 15.2 16.7 18.0 19.3 20.5 21.6 10.8 12.5 14.0 15.3 16.5 17.7 18.7 19.8
OE 9 8.4 9.7 10.8 11.9 12.8 13.7 14.5 15.3 7.2 8.3 9.2 10.1 10.9 11.7 12.4 13.1
OE 12 11.5 13.2 14.8 16.2 17.5 18.7 19.9 20.9 9.8 11.3 12.6 13.8 14.9 16.0 16.9 17.9
OE 21 18.5 21.4 23.9 26.2 28.3 30.3 32.1 33.8 15.8 18.3 20.4 22.4 24.1 25.8 27.4 28.9
OE 30 26.6 30.8 34.4 37.7 40.7 43.5 46.2 48.7 25.0 28.9 32.3 35.4 38.2 40.8 43.3 45.7
OE 35 30.9 35.7 39.9 43.7 47.2 50.4 53.5 56.4 29.0 33.5 37.4 41.0 44.3 47.3 50.2 52.9
OE 45 39.7 45.9 51.3 56.2 60.7 65 69 73 37.3 43.0 48.1 52.7 56.9 60.8 65 68

Nominal Evaporator Temperature °F


Capacity (Tons) 0°F -10°F
Valve Type
or Orifice Pressure Drop (PSI)
Designation 75 100 125 150 175 200 225 250 75 100 125 150 175 200 225 250
N 1/2 0.47 0.54 0.61 0.66 0.72 0.77 0.81 0.86 0.30 0.35 0.39 0.43 0.46 0.49 0.52 0.55
N 2 1.4 1.6 1.8 2.0 2.2 2.3 2.4 2.6 0.93 1.1 1.2 1.3 1.4 1.5 1.6 1.7
SCE AAA 0.18 0.21 0.23 0.25 0.27 0.29 0.31 0.32 0.17 0.20 0.22 0.24 0.26 0.28 0.30 0.31
C(E), EC(E), SCE AA 0.30 0.35 0.39 0.43 0.46 0.50 0.53 0.56 0.28 0.32 0.36 0.39 0.42 0.45 0.48 0.51
C(E), EC(E), SCE A 0.8 1.0 1.1 1.2 1.3 1.3 1.4 1.5 0.53 0.61 0.68 0.75 0.81 0.86 0.91 0.96
C(E), EC(E), SCE B 1.5 1.7 1.9 2.1 2.3 2.5 2.6 2.7 0.99 1.2 1.3 1.4 1.5 1.6 1.7 1.8
C(E), EC(E), SCE C 2.4 2.7 3.0 3.3 3.6 3.8 4.1 4.3 1.5 1.7 1.9 2.1 2.3 2.4 2.6 2.7
C(E), EC(E), SCE D 3.8 4.3 4.9 5.3 5.7 6.1 6.5 6.9 1.9 2.2 2.5 2.7 2.9 3.1 3.3 3.5
EBSE 6 3.6 4.1 4.6 5.1 5.5 5.8 6.2 6.5 2.9 3.4 3.8 4.1 4.5 4.8 5.1 5.4
EBSE 7-1/2 4.8 5.6 6.3 6.9 7.4 7.9 8.4 8.8 3.7 4.3 4.8 5.3 5.7 6.1 6.5 6.8
EBSE 10 5.6 6.5 7.3 7.9 8.6 9.2 9.7 10.3 4.8 5.5 6.1 6.7 7.3 7.8 8.2 8.7
EBSE 13 7.9 9.1 10.2 11.2 12.1 12.9 13.7 14.4 6.8 7.8 8.7 9.5 10.3 11.0 11.7 12.3
OE 9 5.6 6.5 7.2 7.9 8.6 9.2 9.7 10.2 4.3 5.0 5.6 6.1 6.6 7.1 7.5 7.9
OE 12 7.7 8.9 9.9 10.8 11.7 12.5 13.3 14.0 6.9 7.9 8.9 9.7 10.5 11.2 11.9 12.6
OE 21 11.1 12.8 14.3 15.7 16.9 18.1 19.2 20.2 8.2 9.5 10.6 11.7 12.6 13.5 14.3 15.1
OE 30 17.8 20.6 23.0 25.2 27.2 29.1 30.9 32.5 12.3 14.3 15.9 17.5 18.9 20.2 21.4 22.5
OE 35 20.7 23.8 26.7 29.2 31.5 33.7 35.8 37.7 13.4 15.5 17.3 19.0 20.5 21.9 23.2 24.5
OE 45 26.6 30.7 34.3 37.6 40.6 43.4 46 49 15.4 17.8 19.9 21.8 23.6 25.2 26.8 28.2
These ratings are based on vapor free 100°F liquid refrigerant entering the expansion valve, and a maximum of 7°F change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F -10°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-404A 2.04 1.84 1.64 1.43 1.22 1.00 0.77 0.53 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-507
at a 20°F evaporator, 175 psi pressure drop across the TEV, and a 80°F liquid temperature entering the
R-507 1.95 1.76 1.56 1.37 1.18 0.98 0.76 0.50 TEV = 1.91 (from rating chart) x 1.18 (CF liquid temperature) = 2.25 tons
Page 20 / Catalog E-1, Thermostatic & Automatic Expansion Valves

Capacity Tables
R-404A Capacities in Kilowatts (R-507 Refrigerant & Liquid Temperature Correction Factor below)
Nominal Evaporator Temperature °C
Capacity (kW) 5°C -5°C
Valve Type
or Orifice Pressure Drop (BAR)
Designation 4 6 8 10 12 14 16 18 4 6 8 10 12 14 16 18
N 3 1.7 2.1 2.4 2.7 3.0 3.2 3.4 3.6 1.6 2.0 2.3 2.6 2.8 3.0 3.3 3.4
N 7 5.1 6.2 7.2 8.1 8.8 9.6 10.2 10.8 4.9 5.9 6.9 7.7 8.4 9.1 9.7 10.3
SCE AAA 0.59 0.72 0.84 0.93 1.0 1.1 1.2 1.3 0.56 0.69 0.80 0.89 0.97 1.1 1.1 1.2
C(E), EC(E), SCE AA 1.0 1.2 1.4 1.6 1.8 1.9 2.0 2.2 0.97 1.2 1.4 1.5 1.7 1.8 1.9 2.1
C(E), EC(E), SCE A 3.0 3.7 4.2 4.7 5.2 5.6 6.0 6.3 2.8 3.5 4.0 4.5 4.9 5.3 5.7 6.0
C(E), EC(E), SCE B 5.4 6.7 7.7 8.6 9.4 10.2 10.9 11.5 5.2 6.3 7.3 8.2 9.0 9.7 10.3 11.0
C(E), EC(E), SCE C 8.5 10.4 12.0 13.5 14.8 15.9 17.0 18.1 8.1 9.9 11.5 12.8 14.0 15.2 16.2 17.2
C(E), EC(E), SCE D 13.6 16.7 19.3 21.5 23.6 25.5 27.3 28.9 13.0 15.9 18.3 20.5 22.5 24.3 25.9 27.5
EBSE 21 14.4 17.7 20.4 22.8 25.0 27.0 28.9 30.6 12.9 15.8 18.3 20.4 22.4 24.1 25.8 27.4
EBSE 26 19.6 24.0 27.7 31.0 33.9 36.7 39.2 41.6 17.5 21.5 24.8 27.7 30.3 32.8 35.0 37.2
EBSE 35 24.1 29.5 34.1 38.1 41.8 45.1 48.2 51.2 22.0 27.0 31.1 34.8 38.1 41.2 44.0 46.7
EBSE 46 34.4 42.2 48.7 54.4 59.6 64.4 68.9 73.0 31.9 39.0 45.1 50.4 55.2 59.6 63.7 67.6
OE 32 24.5 30.0 34.7 38.8 42.5 45.9 49.1 52.0 21.3 26.1 30.1 33.7 36.9 39.9 42.6 45.2
OE 42 33.6 41.1 47.5 53.1 58.1 62.8 67.1 71.2 29.2 35.7 41.2 46.1 50.5 54.5 58.3 61.8
OE 74 54.2 66.4 76.7 85.7 93.9 101 108 115 47.1 57.7 66.6 74.5 81.6 88.1 94.2 99.9
OE 110 77.6 95.1 110 123 134 145 155 165 73.4 89.9 104 116 127 137 147 156
OE 120 90.0 110 127 142 156 168 180 191 85.1 104 120 134 147 159 170 180
OE 160 116 142 164 183 200 216 231 245 109 134 155 173 189 205 219 232

Nominal Evaporator Temperature °C


Capacity (kW) -15°C -25°C
Valve Type
or Orifice Pressure Drop (BAR)
Designation 4 6 8 10 12 14 16 18 4 6 8 10 12 14 16 18
N 3 1.4 1.8 2.0 2.3 2.5 2.7 2.9 3.1 0.86 1.1 1.2 1.4 1.5 1.6 1.7 1.8
N 7 4.3 5.3 6.1 6.8 7.5 8.1 8.6 9.2 2.6 3.2 3.7 4.2 4.6 5.0 5.3 5.6
SCE AAA 0.53 0.65 0.75 0.84 0.92 1.0 1.1 1.1 0.48 0.59 0.68 0.77 0.84 0.91 1.0 1.0
C(E), EC(E), SCE AA 0.91 1.1 1.3 1.4 1.6 1.7 1.8 1.9 0.79 1.0 1.1 1.2 1.4 1.5 1.6 1.7
C(E), EC(E), SCE A 2.5 3.1 3.6 4.0 4.4 4.7 5.1 5.4 1.5 1.8 2.1 2.4 2.6 2.8 3.0 3.2
C(E), EC(E), SCE B 4.6 5.6 6.5 7.3 8.0 8.6 9.2 9.8 2.8 3.5 4.0 4.5 4.9 5.3 5.6 6.0
C(E), EC(E), SCE C 7.2 8.8 10.2 11.4 12.5 13.5 14.4 15.3 4.2 5.2 6.0 6.7 7.3 7.9 8.4 8.9
C(E), EC(E), SCE D 11.5 14.1 16.3 18.2 20.0 21.6 23.1 24.5 5.3 6.5 7.5 8.4 9.2 9.9 10.6 11.3
EBSE 21 10.9 13.4 15.5 17.3 18.9 20.5 21.9 23.2 8.0 9.8 11.3 12.6 13.8 14.9 16.0 16.9
EBSE 26 14.8 18.2 21.0 23.5 25.7 27.8 29.7 31.5 10.2 12.4 14.4 16.1 17.6 19.0 20.3 21.6
EBSE 35 17.6 21.6 24.9 27.9 30.5 33.0 35.2 37.4 13.1 16.0 18.5 20.7 22.7 24.5 26.2 27.8
EBSE 46 25.0 30.6 35.4 39.5 43.3 46.8 50.0 53.0 18.6 22.8 26.4 29.5 32.2 34.9 37.3 39.6
OE 32 17.4 21.3 24.6 27.5 30.1 32.5 34.8 36.9 12.1 14.8 17.0 19.1 20.9 22.5 24.1 25.6
OE 42 23.8 29.1 33.6 37.6 41.2 44.5 47.6 50.5 19.2 23.5 27.2 30.4 33.3 35.9 38.4 40.7
OE 74 35.5 43.5 50.2 56.1 61.5 66.4 71.0 75.3 23.0 28.2 32.5 36.4 39.9 43.1 46.0 48.8
OE 110 56.8 69.6 80.4 89.9 98.5 106 114 121 34.5 42.2 48.7 54.5 59.7 64.5 68.9 73.1
OE 120 65.9 80.7 93.2 104 114 123 132 140 37.4 45.8 52.9 59.2 64.8 70.0 74.8 79.4
OE 160 84.7 104 120 134 147 158 169 180 43.1 52.8 61.0 68.2 74.7 80.7 86.3 91.5
These ratings are based on vapor free 40°C liquid refrigerant entering the expansion valve, and a maximum of 4°C change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -25°C to 5°C since the variation in the actual factors across this range is insignificant.
Correction Factor
R-404A 1.98 1.79 1.60 1.41 1.21 1.00 0.79 0.56 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an SCE-B using R-507
at a -5°C evaporator, 12 bar pressure drop across the TEV, and a 30°C liquid temperature entering the
R-507 1.89 1.71 1.53 1.35 1.17 0.98 0.78 0.53 TEV = 6.72 (from rating chart) x 1.17 (CF liquid temperature) = 7.86 kW
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 21

Capacity Tables
R-410A Capacities in Tons
Nominal Evaporator Temperature °F
Capacity (Tons) 40°F 20°F 0°F
Valve Type
or Orifice Pressure Drop (PSI)
Designation 120 160 200 240 280 320 120 160 200 240 280 320 120 160 200 240 280 320
H(E), HC(E) 1-1/2 1.3 1.5 1.7 1.8 2.0 2.1 1.3 1.5 1.6 1.8 1.9 2.1 1.2 1.4 1.6 1.7 1.9 2.0
H(E), HC(E) 3 2.6 3.0 3.4 3.7 4.0 4.2 2.6 2.9 3.3 3.6 3.9 4.2 2.4 2.8 3.2 3.5 3.7 4.0
H(E), HC(E) 5 4.3 5.0 5.6 6.1 6.6 7.1 4.4 4.9 5.5 6.0 6.5 6.9 4.1 4.7 5.3 5.8 6.2 6.7
ECE AA 0.62 0.72 0.80 0.88 0.95 1.0 0.61 0.70 0.78 0.86 0.93 0.99 0.53 0.61 0.69 0.75 0.81 0.87
ECE A 1.8 2.1 2.3 2.6 2.8 3.0 1.8 2.1 2.3 2.5 2.7 2.9 1.6 1.8 2.0 2.2 2.4 2.6
ECE B 3.3 3.8 4.3 4.7 5.1 5.4 3.2 3.7 4.2 4.6 5.0 5.3 2.9 3.3 3.7 4.1 4.4 4.7
ECE C 5.2 6.0 6.7 7.3 7.9 8.5 5.1 5.9 6.5 7.2 7.7 8.3 4.5 5.2 5.8 6.4 6.9 7.4
ECE D 8.3 9.6 10.7 11.7 12.7 13.6 8.1 9.4 10.5 11.5 12.4 13.2 7.2 8.4 9.3 10.2 11.1 11.8
ECE 12-1/2 10.8 12.5 14.0 15.3 16.5 17.7 10.6 12.2 13.6 14.9 16.1 17.2 9.4 10.9 12.2 13.3 14.4 15.4
ECE 15 12.6 14.5 16.2 17.8 19.2 20.5 12.3 14.1 15.8 17.3 18.7 20.0 10.9 12.6 14.1 15.5 16.7 17.9
OE 20 17.3 20.0 22.4 24.5 26.5 28.3 16.9 19.5 21.8 23.9 25.8 27.6 15.9 18.4 20.6 22.5 24.3 26.0
OE 25 20.8 24.0 26.8 29.4 31.7 33.9 20.3 23.4 26.2 28.7 31.0 33.1 19.1 22.1 24.7 27.0 29.2 31.2
OE 35 28.6 33.0 36.9 40.4 43.7 46.7 27.9 32.2 36.0 39.4 42.6 45.5 26.3 30.3 33.9 37.2 40.1 42.9
OE 50 43.3 50.0 55.9 61.2 66.1 70.7 42.2 48.8 54.5 59.7 64.5 69.0 39.8 46.0 51.4 56.3 60.8 65.0
OE 60 52.0 60.0 67.1 73.5 79.4 84.8 50.7 58.5 65.4 71.7 77.4 82.8 47.8 55.2 61.7 67.5 73.0 78.0
These ratings are based on vapor free 100°F liquid refrigerant entering the expansion valve, and a maximum of 7°F change in superheat.
Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F 0°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor, CF Liquid Temperature
R-410A 1.79 1.63 1.47 1.32 1.16 1.00 0.83 0.62 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an HCE-3 using R-410A
at a 40°F evaporator, 160 psi pressure drop across the TEV, and a 80°F liquid temperature entering the
TEV = 3.00 (from rating chart) x 1.16 (CF liquid temperature) = 3.48 tons

R-410A Capacities in Kilowatts


Nominal Evaporator Temperature °C
Capacity (kW) 5°C -5°C -15°C
Valve Type
or Orifice Pressure Drop (BAR)
Designation 8 11 14 17 20 23 8 11 14 17 20 23 8 11 14 17 20 23
H(E), HC(E) 5 4.5 5.3 5.9 6.6 7.1 7.6 4.4 5.2 5.8 6.4 6.9 7.5 4.3 5.0 5.7 6.3 6.7 7.3
H(E), HC(E) 11 9.0 10.5 11.9 13.1 14.2 15.2 8.8 10.3 11.6 12.8 13.9 14.9 8.6 10.0 11.3 12.5 13.3 14.5
H(E), HC(E) 18 15.0 17.6 19.8 21.8 23.7 25.4 14.7 17.2 19.4 21.4 23.2 24.9 14.3 16.7 18.9 20.8 22.3 24.2
ECE AA 2.1 2.5 2.8 3.0 3.3 3.5 2.0 2.4 2.7 3.0 3.2 3.5 1.8 2.2 2.4 2.7 2.9 3.1
ECE A 6.1 7.1 8.1 8.9 9.6 10.3 6.0 7.0 7.9 8.7 9.4 10.1 5.5 6.4 7.2 8.0 8.6 9.3
ECE B 11.1 13.1 14.7 16.2 17.6 18.9 10.9 12.8 14.4 15.9 17.2 18.5 10.0 11.7 13.2 14.5 15.8 16.9
ECE C 17.4 20.4 23.0 25.4 27.5 29.5 17.0 19.9 22.5 24.8 26.9 28.8 15.6 18.3 20.6 22.7 24.6 26.4
ECE D 27.8 32.6 36.8 40.6 44.0 47.2 27.2 31.9 36.0 39.7 43.0 46.2 24.9 29.2 33.0 36.3 39.4 42.3
ECE 44 36.3 42.5 48.0 52.9 57.4 61.5 35.5 41.6 46.9 51.7 56.1 60.2 32.5 38.1 43.0 47.4 51.4 55.1
ECE 53 42.1 49.5 55.7 61.4 66.5 71.4 41.2 48.3 54.4 60.0 65.1 69.8 37.7 44.2 49.9 54.9 59.6 63.9
OE 70 57.3 67.1 75.8 83.5 90.5 97.1 56.2 65.9 74.3 81.9 88.8 95.2 53.7 62.9 70.9 78.1 84.7 90.9
OE 88 68.7 80.6 90.9 100 109 117 67.4 79.0 89.2 98.2 107 114 64.3 75.4 85.1 93.8 102 109
OE 123 94.5 111 125 138 149 160 92.7 109 123 135 147 157 88.4 104 117 129 140 150
OE 176 143 168 189 209 226 243 140 165 186 205 222 238 134 157 177 195 212 227
OE 211 172 201 227 250 272 291 168 198 223 246 266 286 161 189 213 234 254 273
These ratings are based on vapor free 40°C liquid refrigerant entering the expansion valve, and a maximum of 4°C change in superheat.

Liquid Temperature Entering TEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -15°C to 5°C since the variation in the actual factors across this range is insignificant.
Correction Factor, CF Liquid Temperature
R-410A 1.73 1.59 1.44 1.30 1.15 1.00 0.84 0.65 TEV Capacity = TEV Rating x CF Liquid Temperature – Example: Actual capacity of an HCE-3 using R-
410A at a 5°C evaporator, 11 bar pressure drop across the TEV, and a 30°C liquid temperature entering
the TEV = 10.5 (from rating chart) x 1.15 (CF liquid temperature) = 12.1 kW
Page 22 / Catalog E-1, Thermostatic & Automatic Expansion Valves

A Series Constant Pressure (Automatic) Valves


Specifications Model No. Equalizer
Connections ( Inches)
Inlet Outlet
■■0-90 psig adjustment range
AS Internal 1/4 ODF 3/8 ODF
■■Bypass bleeds available A1 Internal 1/4 ODF 1/4 NPTF
■■Construction: Brass, copper and stainless A1 Internal 1/4 SAE 1/4 NPTF
steel A2* Internal 1/4 SAE 1/2 SAE
A3 Internal 3/8 SAE 1/2 SAE
■■Internally equalized
A4 Internal 1/4 SAE 1/2 SAE
■■U.L. recognized for maximum operating A4 Internal 3/8 SAE 1/2 SAE
pressure of 500 psig high side, 400 psig A7 Internal 1/4 ODF 1/4 ODF
low side A7 Internal 1/4 ODF 3/8 ODF
A7 Internal 3/8 ODF 3/8 ODF
A7 Internal 3/8 SAE 3/8 SAE
AT Internal 1/4 SAE 1/4 NPTF
AT Internal 1/4 ODF 1/4 NPTF
*1/2" x 3/8" SAE flare adaptor available.

1.50”
Model A7 Model AS 38 mm
2.00”
51 mm

Outlet
4.36”
111 mm
Outlet

Inlet 2.10”
53 mm
1.16”
29 mm
Inlet
1.40”
36 mm

Model AT Model A1
2.00” 1.50”
51 mm 38 mm

3.80” 3.67”
97 mm Inlet 93 mm
Ref

1.64 1.38”
42 mm 35 mm

Outlet
1.31 1.27”
33 mm 32 mm
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 23

A Series Constant Pressure (Automatic) Valves


Model A2
1.50”
38 mm

3.67”
93 mm
Inlet Ref

1.38”
35 mm

Outlet
1.27”
32 mm

Model A3
1.50”
38 mm

3.67”
93 mm
Inlet Ref

1.38”
35 mm

Outlet
1.27”
32 mm
Model A4
1.50”
38 mm

3.67”
93 mm
Ref
Inlet

1.38”
35 mm

Outlet
1.27”
32 mm
Page 24 / Catalog E-1, Thermostatic & Automatic Expansion Valves

Capacity Tables
R-134a Capacities in Tons (R-401A, R-409A Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature °F
Nominal Capacity
40°F 20°F 0°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
40 60 80 100 120 140 60 80 100 120 140 160 60 80 100 120 140 160
A1, A2, AT B 2 1 to 2 1.63 2.00 2.31 2.58 2.83 3.06 1.90 2.19 2.45 2.69 2.90 3.10 1.70 1.96 2.19 2.40 2.60 2.78
A4 — 1/2 1/4 to 3/4 0.61 0.75 0.87 0.97 1.06 1.15 0.71 0.82 0.92 1.01 1.09 1.16 0.64 0.74 0.82 0.90 0.97 1.04
A7-AA AA 1/2 1/8 to 1/2 0.41 0.50 0.58 0.65 0.71 0.76 0.48 0.55 0.61 0.67 0.73 0.78 0.43 0.49 0.55 0.60 0.65 0.69
A7-A A 1 1/4 to 1 0.82 1.00 1.15 1.29 1.41 1.53 0.95 1.10 1.23 1.34 1.45 1.55 0.85 0.98 1.10 1.20 1.30 1.39
A7-B B 2 1 to 2 1.63 2.00 2.31 2.58 2.83 3.06 1.90 2.19 2.45 2.69 2.90 3.10 1.70 1.96 2.19 2.40 2.60 2.78
A7-C C 3 1-1/2 to 3 2.45 3.00 3.46 3.87 4.24 4.58 2.85 3.29 3.68 4.03 4.35 4.65 2.55 2.94 3.29 3.61 3.90 4.16
AS, ASB20 — 1 1/4 to 1 0.82 1.00 1.15 1.29 1.41 1.53 0.95 1.10 1.23 1.34 1.45 1.55 0.85 0.98 1.10 1.20 1.30 1.39

Evaporator Temperature °F
Nominal Capacity
-10°F -20°F -40°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
80 100 120 140 160 180 80 100 120 140 160 180 80 100 120 140 160 180
A1, A2, AT B 2 1 to 2 1.64 1.83 2.01 2.17 2.32 2.46 1.34 1.50 1.64 1.77 1.89 2.01 0.88 0.98 1.07 1.16 1.24 1.32
A4 — 1/2 1/4 to 3/4 0.61 0.69 0.75 0.81 0.87 0.92 0.50 0.56 0.62 0.66 0.71 0.75 0.33 0.37 0.40 0.44 0.47 0.49
A7-AA AA 1/2 1/8 to 1/2 0.41 0.46 0.50 0.54 0.58 0.61 0.33 0.37 0.41 0.44 0.47 0.50 0.22 0.25 0.27 0.29 0.31 0.33
A7-A A 1 1/4 to 1 0.82 0.92 1.00 1.08 1.16 1.23 0.67 0.75 0.82 0.89 0.95 1.00 0.44 0.49 0.54 0.58 0.62 0.66
A7-B B 2 1 to 2 1.64 1.83 2.01 2.17 2.32 2.46 1.34 1.50 1.64 1.77 1.89 2.01 0.88 0.98 1.07 1.16 1.24 1.32
A7-C C 3 1-1/2 to 3 2.46 2.75 3.01 3.25 3.48 3.69 2.01 2.25 2.46 2.66 2.84 3.01 1.32 1.47 1.61 1.74 1.86 1.97
AS, ASB20 — 1 1/4 to 1 0.82 0.92 1.00 1.08 1.16 1.23 0.67 0.75 0.82 0.89 0.95 1.00 0.44 0.49 0.54 0.58 0.62 0.66
■ Gold areas are standard conditions.

Liquid Temperature Entering AEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F -40°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-134a 1.69 1.56 1.42 1.29 1.14 1.00 0.85 0.71 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-409A
at a 20°F evaporator, 120 psi pressure drop across the AEV, and a 80°F liquid temperature entering the
R-401A 1.75 1.62 1.49 1.36 1.23 1.09 0.95 0.81 AEV = 2.69 (from rating chart) x 1.19 (CF liquid temperature) = 3.20 tons
R-409A 1.65 1.54 1.42 1.31 1.19 1.06 0.94 0.81

R-134a Capacities in Kilowatts (R-401A, R-409A Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature °C
Nominal Capacity
10°C 0°C -10°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
3 4 6 7 8 10 4 6 7 8 10 11 4 6 7 8 10 11
A1, A2, AT B 7 4 to 7 6.21 7.17 8.79 9.49 10.1 11.3 6.89 8.44 9.11 9.74 10.9 11.4 6.46 7.91 8.54 9.13 10.2 10.7
A4 — 3 1 to 3 2.33 2.69 3.30 3.56 3.80 4.25 2.58 3.16 3.42 3.65 4.08 4.28 2.42 2.97 3.20 3.42 3.83 4.02
A7-AA AA 2 1/2 to 2 1.55 1.79 2.20 2.37 2.54 2.84 1.72 2.11 2.28 2.44 2.72 2.86 1.61 1.98 2.14 2.28 2.55 2.68
A7-A A 4 1 to 4 3.11 3.59 4.39 4.75 5.07 5.67 3.44 4.22 4.56 4.87 5.45 5.71 3.23 3.95 4.27 4.57 5.10 5.35
A7-B B 7 4 to 7 6.21 7.17 8.79 9.49 10.1 11.3 6.89 8.44 9.11 9.74 10.9 11.4 6.46 7.91 8.54 9.13 10.2 10.7
A7-C C 11 5 to 11 9.32 10.8 13.2 14.2 15.2 17.0 10.3 12.7 13.7 14.6 16.3 17.1 9.69 11.9 12.8 13.7 15.3 16.1
AS, ASB20 — 4 1 to 4 3.11 3.59 4.39 4.75 5.07 5.67 3.44 4.22 4.56 4.87 5.45 5.71 3.23 3.95 4.27 4.57 5.10 5.35

Evaporator Temperature°C
Nominal Capacity
-20°C -30°C -40°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
6 7 8 10 11 12 6 7 8 10 11 12 6 7 8 10 11 12
A1, A2, AT B 7 4 to 7 6.77 7.31 7.81 8.74 9.16 9.57 5.01 5.41 5.78 6.47 6.78 7.08 3.25 3.51 3.75 4.20 4.40 4.60
A4 — 3 1 to 3 2.54 2.74 2.93 3.28 3.44 3.59 1.88 2.03 2.17 2.42 2.54 2.66 1.22 1.32 1.41 1.57 1.65 1.72
A7-AA AA 2 1/2 to 2 1.69 1.83 1.95 2.18 2.29 2.39 1.25 1.35 1.45 1.62 1.70 1.77 0.81 0.88 0.94 1.05 1.10 1.15
A7-A A 4 1 to 4 3.38 3.65 3.91 4.37 4.58 4.78 2.50 2.70 2.89 3.23 3.39 3.54 1.63 1.76 1.88 2.10 2.20 2.30
A7-B B 7 4 to 7 6.77 7.31 7.81 8.74 9.16 9.57 5.01 5.41 5.78 6.47 6.78 7.08 3.25 3.51 3.75 4.20 4.40 4.60
A7-C C 11 5 to 11 10.1 11.0 11.7 13.1 13.7 14.4 7.51 8.11 8.68 9.70 10.2 10.6 4.88 5.27 5.63 6.30 6.60 6.90
AS, ASB20 — 4 1 to 4 3.38 3.65 3.91 4.37 4.58 4.78 2.50 2.70 2.89 3.23 3.39 3.54 1.63 1.76 1.88 2.10 2.20 2.30
■ Gold areas are standard conditions.

Liquid Temperature Entering AEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -40°C to 10°C since the variation in the actual factors across this range is insignificant.
Correction Factor
R-134a 1.64 1.52 1.39 1.26 1.13 1.00 0.87 0.73 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-409A
at a 0°C evaporator, 8 bar pressure drop across the AEV, and a 30°C liquid temperature entering the
R-401A 1.70 1.59 1.46 1.34 1.22 1.09 0.96 0.83 AEV = 9.74 (from rating chart) x 1.18 (CF liquid temperature) = 11.5 kW
R-409A 1.61 1.50 1.40 1.29 1.18 1.07 0.95 0.83
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 25

Capacity Tables
R-22 Capacities in Tons (R-407C Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature°F
Nominal Capacity
40°F 20°F 0°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
75 100 125 150 175 200 75 100 125 150 175 200 75 100 125 150 175 200
A1, A2, AT B 3 1-1/2 to 3 2.60 3.00 3.35 3.67 3.97 4.24 2.55 2.94 3.29 3.60 3.89 4.16 2.29 2.64 2.95 3.23 3.49 3.73
A4 — 1 1/2 to 1 0.87 1.00 1.12 1.22 1.32 1.41 0.85 0.98 1.10 1.20 1.30 1.39 0.76 0.88 0.98 1.08 1.16 1.24
A7-AA AA 3/4 1/5 to 3/4 0.65 0.75 0.84 0.92 0.99 1.06 0.64 0.74 0.82 0.90 0.97 1.04 0.57 0.66 0.74 0.81 0.87 0.93
A7-A A 1-1/2 1/2 to 1-1/2 1.30 1.50 1.68 1.84 1.98 2.12 1.27 1.47 1.64 1.80 1.94 2.08 1.14 1.32 1.48 1.62 1.75 1.87
A7-B B 3 1-1/2 to 3 2.60 3.00 3.35 3.67 3.97 4.24 2.55 2.94 3.29 3.60 3.89 4.16 2.29 2.64 2.95 3.23 3.49 3.73
A7-C C 5 3-1/2 to 5 4.33 5.00 5.59 6.12 6.61 7.07 4.24 4.90 5.48 6.00 6.48 6.93 3.81 4.40 4.92 5.39 5.82 6.22
AS, ASB20 — 1-1/2 1/2 to 1-1/2 1.30 1.50 1.68 1.84 1.98 2.12 1.27 1.47 1.64 1.80 1.94 2.08 1.14 1.32 1.48 1.62 1.75 1.87

Evaporator Temperature °F
Nominal Capacity
-10°F -20°F -40°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
100 125 150 175 200 225 125 150 175 200 225 250 125 150 175 200 225 250
A1, A2, AT B 3 1-1/2 to 3 2.22 2.48 2.72 2.94 3.14 3.33 2.05 2.24 2.42 2.59 2.75 2.89 1.38 1.51 1.63 1.74 1.85 1.94
A4 — 1 1/2 to 1 0.74 0.83 0.91 0.98 1.05 1.11 0.68 0.75 0.81 0.86 0.92 0.96 0.46 0.50 0.54 0.58 0.62 0.65
A7-AA AA 3/4 1/5 to 3/4 0.56 0.62 0.68 0.73 0.78 0.83 0.51 0.56 0.61 0.65 0.69 0.72 0.34 0.38 0.41 0.43 0.46 0.49
A7-A A 1-1/2 1/2 to 1-1/2 1.11 1.24 1.36 1.47 1.57 1.67 1.02 1.12 1.21 1.29 1.37 1.45 0.69 0.75 0.81 0.87 0.92 0.97
A7-B B 3 1-1/2 to 3 2.22 2.48 2.72 2.94 3.14 3.33 2.05 2.24 2.42 2.59 2.75 2.89 1.38 1.51 1.63 1.74 1.85 1.94
A7-C C 5 3-1/2 to 5 3.70 4.14 4.53 4.89 5.23 5.55 3.41 3.74 4.03 4.31 4.58 4.82 2.29 2.51 2.71 2.90 3.08 3.24
AS, ASB20 — 1-1/2 1/2 to 1-1/2 1.11 1.24 1.36 1.47 1.57 1.67 1.02 1.12 1.21 1.29 1.37 1.45 0.69 0.75 0.81 0.87 0.92 0.97
■ Gold areas are standard conditions.
Liquid Temperature Entering AEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F -40°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-22 1.57 1.45 1.34 1.23 1.12 1.00 0.88 0.76 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-407C
at a 40°F evaporator, 125 psi pressure drop across the AEV, and a 80°F liquid temperature entering the
R-407C 1.58 1.45 1.32 1.18 1.04 0.89 0.74 0.57 AEV = 3.35 (from rating chart) x 1.04 (CF liquid temperature) = 3.48 tons

R-22 Capacities in Kilowatts (R-407C Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature °C
Nominal Capacity
10°C 0°C -10°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
5 7 9 10 12 14 5 7 9 10 12 14 7 9 10 12 14 16
A1, A2, AT B 11 5 to 11 9.01 10.7 12.1 12.7 14.0 15.1 8.83 10.4 11.8 12.5 13.7 14.8 10.1 11.5 12.1 13.3 14.3 15.3
A4 — 4 2 to 4 3.00 3.55 4.03 4.25 4.65 5.02 2.94 3.48 3.95 4.16 4.56 4.92 3.37 3.83 4.03 4.42 4.77 5.10
A7-AA AA 3 3/4 to 3 2.25 2.66 3.02 3.18 3.49 3.77 2.21 2.61 2.96 3.12 3.42 3.69 2.53 2.87 3.03 3.31 3.58 3.83
A7-A A 5 2 to 5 4.50 5.33 6.04 6.37 6.98 7.54 4.41 5.22 5.92 6.24 6.84 7.38 5.06 5.74 6.05 6.63 7.16 7.65
A7-B B 11 5 to 11 9.01 10.7 12.1 12.7 14.0 15.1 8.83 10.4 11.8 12.5 13.7 14.8 10.1 11.5 12.1 13.3 14.3 15.3
A7-C C 18 12 to 18 15.0 17.8 20.1 21.2 23.3 25.1 14.7 17.4 19.7 20.8 22.8 24.6 16.9 19.1 20.2 22.1 23.9 25.5
AS, ASB20 — 5 2 to 5 4.50 5.33 6.04 6.37 6.98 7.54 4.41 5.22 5.92 6.24 6.84 7.38 5.06 5.74 6.05 6.63 7.16 7.65

Evaporator Temperature °C
Nominal Capacity
-20°C -30°C -40°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
9 10 12 14 16 17 9 10 12 14 16 17 9 10 12 14 16 17
A1, A2, AT B 11 5 to 11 9.79 10.3 11.3 12.2 13.1 13.5 7.25 7.64 8.37 9.04 9.67 9.96 4.83 5.09 5.58 6.03 6.44 6.64
A4 — 4 2 to 4 3.26 3.44 3.77 4.07 4.35 4.48 2.42 2.55 2.79 3.01 3.22 3.32 1.61 1.70 1.86 2.01 2.15 2.21
A7-AA AA 3 3/4 to 3 2.45 2.58 2.83 3.05 3.26 3.36 1.81 1.91 2.09 2.26 2.42 2.49 1.21 1.27 1.40 1.51 1.61 1.66
A7-A A 5 2 to 5 4.89 5.16 5.65 6.10 6.53 6.73 3.63 3.82 4.19 4.52 4.83 4.98 2.42 2.55 2.79 3.01 3.22 3.32
A7-B B 11 5 to 11 9.79 10.3 11.3 12.2 13.1 13.5 7.25 7.64 8.37 9.04 9.67 9.96 4.83 5.09 5.58 6.03 6.44 6.64
A7-C C 18 12 to 18 16.3 17.2 18.8 20.3 21.8 22.4 12.1 12.7 14.0 15.1 16.1 16.6 8.06 8.49 9.30 10.0 10.7 11.1
AS, ASB20 — 5 2 to 5 4.89 5.16 5.65 6.10 6.53 6.73 3.63 3.82 4.19 4.52 4.83 4.98 2.42 2.55 2.79 3.01 3.22 3.32
■ Gold areas are standard conditions.
Liquid Temperature Entering AEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -40°C to 10°C since the variation in the actual factors across this range is insignificant.
Correction Factor
R-22 1.52 1.42 1.32 1.21 1.11 1.00 0.89 0.78 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-407C
at a 10°C evaporator, 7 bar pressure drop across the AEV, and a 30°C liquid temperature entering the
R-407C 1.53 1.41 1.28 1.15 1.02 0.88 0.74 0.59 AEV = 10.7 (from rating chart) x 1.02 (CF liquid temperature) = 10.9 kW
Page 26 / Catalog E-1, Thermostatic & Automatic Expansion Valves

Capacity Tables
R-404A Capacities in Tons (R-507 Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature °F
Nominal Capacity
40°F 20°F 0°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
75 100 125 150 175 200 75 100 125 150 175 200 75 100 125 150 175 200
A1, A2, AT B 2 1 to 2 1.73 2.00 2.24 2.45 2.65 2.83 1.66 1.92 2.15 2.35 2.54 2.72 1.51 1.74 1.95 2.13 2.30 2.46
A4 — 1/2 1/4 to 3/4 0.65 0.75 0.84 0.92 0.99 1.06 0.62 0.72 0.80 0.88 0.95 1.02 0.57 0.65 0.73 0.80 0.86 0.92
A7-AA AA 1/2 1/8 to 1/2 0.43 0.50 0.56 0.61 0.66 0.71 0.42 0.48 0.54 0.59 0.63 0.68 0.38 0.44 0.49 0.53 0.58 0.62
A7-A A 1 1/4 to 1 0.87 1.00 1.12 1.22 1.32 1.41 0.83 0.96 1.07 1.18 1.27 1.36 0.75 0.87 0.97 1.07 1.15 1.23
A7-B B 2 1 to 2 1.73 2.00 2.24 2.45 2.65 2.83 1.66 1.92 2.15 2.35 2.54 2.72 1.51 1.74 1.95 2.13 2.30 2.46
A7-C C 4 1-1/2 to 4 3.46 4.00 4.47 4.90 5.29 5.66 3.33 3.84 4.29 4.70 5.08 5.43 3.01 3.48 3.89 4.26 4.60 4.92
AS, ASB20 — 1 1/4 to 1 0.87 1.00 1.12 1.22 1.32 1.41 0.83 0.96 1.07 1.18 1.27 1.36 0.75 0.87 0.97 1.07 1.15 1.23

Evaporator Temperature °F
Nominal Capacity
-10°F -20°F -40°F
Valve Type Orifice Capacity Range
Pressure Drop (PSI)
(Tons) (Tons)
100 125 150 175 200 225 125 150 175 200 225 250 125 150 175 200 225 250
A1, A2, AT B 2 1 to 2 1.48 1.65 1.81 1.96 2.09 2.22 1.36 1.49 1.61 1.73 1.83 1.93 0.87 0.96 1.03 1.10 1.17 1.23
A4 — 1/2 1/4 to 3/4 0.56 0.62 0.68 0.73 0.78 0.83 0.51 0.56 0.61 0.65 0.69 0.72 0.33 0.36 0.39 0.41 0.44 0.46
A7-AA AA 1/2 1/8 to 1/2 0.37 0.41 0.45 0.49 0.52 0.56 0.34 0.37 0.40 0.43 0.46 0.48 0.22 0.24 0.26 0.28 0.29 0.31
A7-A A 1 1/4 to 1 0.74 0.83 0.91 0.98 1.05 1.11 0.68 0.75 0.81 0.86 0.92 0.96 0.44 0.48 0.52 0.55 0.59 0.62
A7-B B 2 1 to 2 1.48 1.65 1.81 1.96 2.09 2.22 1.36 1.49 1.61 1.73 1.83 1.93 0.87 0.96 1.03 1.10 1.17 1.23
A7-C C 4 1-1/2 to 4 2.96 3.31 3.63 3.92 4.19 4.44 2.73 2.99 3.23 3.45 3.66 3.86 1.74 1.91 2.06 2.21 2.34 2.47
AS, ASB20 — 1 1/4 to 1 0.74 0.83 0.91 0.98 1.05 1.11 0.68 0.75 0.81 0.86 0.92 0.96 0.44 0.48 0.52 0.55 0.59 0.62
■ Gold areas are standard conditions.

Liquid Temperature Entering AEV These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from
Refrigerant 0°F 20°F 40°F 60°F 80°F 100°F 120°F 140°F -40°F to 40°F since the variation in the actual factors across this range is insignificant.
Correction Factor
R-404A 2.04 1.84 1.64 1.43 1.22 1.00 0.77 0.53 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-507
at a 20°F evaporator, 175 psi pressure drop across the AEV, and a 80°F liquid temperature entering the
R-507 1.95 1.76 1.56 1.37 1.18 0.98 0.76 0.50 AEV = 2.54 (from rating chart) x 1.18 (CF liquid temperature) = 3.00 tons

R-404A Capacities in Kilowatts (R-507 Refrigerant & Liquid Temperature Correction Factor below)
Evaporator Temperature °C
Nominal Capacity
10°C 0°C -10°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
5 7 9 10 12 14 5 7 9 10 12 14 5 7 9 10 12 14
A1, A2, AT B 7 4 to 7 6.06 7.17 8.14 8.58 9.39 10.1 5.88 6.96 7.89 8.32 9.11 9.84 5.58 6.60 7.48 7.89 8.64 9.33
A4 — 3 1 to 3 2.27 2.69 3.05 3.22 3.52 3.80 2.21 2.61 2.96 3.12 3.42 3.69 2.09 2.48 2.81 2.96 3.24 3.50
A7-AA AA 2 1/2 to 2 1.52 1.79 2.03 2.14 2.35 2.54 1.47 1.74 1.97 2.08 2.28 2.46 1.39 1.65 1.87 1.97 2.16 2.33
A7-A A 4 1 to 4 3.03 3.59 4.07 4.29 4.70 5.07 2.94 3.48 3.95 4.16 4.56 4.92 2.79 3.30 3.74 3.94 4.32 4.67
A7-B B 7 4 to 7 6.06 7.17 8.14 8.58 9.39 10.1 5.88 6.96 7.89 8.32 9.11 9.84 5.58 6.60 7.48 7.89 8.64 9.33
A7-C C 14 5 to 14 12.1 14.3 16.3 17.2 18.8 20.3 11.8 13.9 15.8 16.6 18.2 19.7 11.2 13.2 15.0 15.8 17.3 18.7
AS, ASB20 — 4 1 to 4 3.03 3.59 4.07 4.29 4.70 5.07 2.94 3.48 3.95 4.16 4.56 4.92 2.79 3.30 3.74 3.94 4.32 4.67

Evaporator Temperature °C
Nominal Capacity
-20°C -30°C -40°C
Valve Type Orifice Capacity Range
Pressure Drop (BAR)
(kW) (kW)
7 9 10 12 14 16 9 10 12 14 16 17 9 10 12 14 16 17
A1, A2, AT B 7 4 to 7 5.67 6.43 6.77 7.42 8.02 8.57 4.80 5.06 5.54 5.99 6.40 6.60 3.09 3.26 3.57 3.86 4.12 4.25
A4 — 3 1 to 3 2.13 2.41 2.54 2.78 3.01 3.21 1.80 1.90 2.08 2.24 2.40 2.47 1.16 1.22 1.34 1.45 1.55 1.59
A7-AA AA 2 1/2 to 2 1.42 1.61 1.69 1.86 2.00 2.14 1.20 1.26 1.39 1.50 1.60 1.65 0.77 0.81 0.89 0.96 1.03 1.06
A7-A A 4 1 to 4 2.83 3.21 3.39 3.71 4.01 4.28 2.40 2.53 2.77 2.99 3.20 3.30 1.55 1.63 1.78 1.93 2.06 2.12
A7-B B 7 4 to 7 5.67 6.43 6.77 7.42 8.02 8.57 4.80 5.06 5.54 5.99 6.40 6.60 3.09 3.26 3.57 3.86 4.12 4.25
A7-C C 14 5 to 14 11.3 12.9 13.5 14.8 16.0 17.1 9.60 10.1 11.1 12.0 12.8 13.2 6.18 6.52 7.14 7.71 8.24 8.50
AS, ASB20 — 4 1 to 4 2.83 3.21 3.39 3.71 4.01 4.28 2.40 2.53 2.77 2.99 3.20 3.30 1.55 1.63 1.78 1.93 2.06 2.12
■Gold areas are standard conditions.
These factors include corrections for liquid refrigerant density and net refrigerating effect, and are based
Liquid Temperature Entering AEV
on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from
Refrigerant -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C -40°C to 10°C since the variation in the actual factors across this range is insignificant.
Correction Factor
R-404A 1.98 1.79 1.60 1.41 1.21 1.00 0.79 0.56 AEV Capacity = AEV Rating x CF Liquid Temperature – Example: Actual capacity of an A7-B using R-507
at a 0°C evaporator, 12 bar pressure drop across the AEV, and a 30°C liquid temperature entering the
R-507 1.89 1.71 1.53 1.35 1.17 0.98 0.78 0.53 AEV = 9.11 (from rating chart) x 1.17 (CF liquid temperature) = 10.7 kW
Catalog E-1, Thermostatic & Automatic Expansion Valves / Page 27

PARKER CIC GROUP AFTERMARKET - OFFER OF SALE


The goods, services or work (referred to as the “Products”) offered by Parker-Hannifin Corporation, CIC Group Aftermarket (“Seller”) are offered for sale at prices to
be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for any
Products described in its document or the attached proposal, quote or offer, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer.

1. Terms and Conditions. Seller’s willingness to the application and follow applicable industry stan- or custodian for all or any part of Buyer’s property
offer Products for sale or accept an order for Products dards and Product information. If Seller provides (c) files a petition for relief in bankruptcy on its own
is subject to the terms and conditions contained in this Product or system options, the user is responsible behalf, or by a third party (d) makes an assignment for
Offer of Sale (also referred to as the “Terms & Condi- for determining that such data and specifications are the benefit of creditors, or (e) dissolves or liquidates
tions”) or any newer version of the same, published by suitable and sufficient for all applications and reason- all or a majority of its assets.
Seller electronically at www.parker.com/saleterms/. ably foreseeable uses of the Products or systems. 17. Governing Law. This agreement and the sale
Seller objects to any contrary or additional terms or 8. Loss to Buyer’s Property. Any designs, tools, and delivery of all Products are deemed to have
conditions of Buyer’s order or any other document or patterns, materials, drawings, confidential informa- taken place in, and shall be governed and construed
other communication issued by Buyer. tion or equipment furnished by Buyer or any other in accordance with, the laws of the State of Ohio, as
2. Price; Payment. Prices stated on Seller’s offer, items which become Buyer’s property, will be con- applicable to contracts executed and wholly per-
proposal or quote (“Quote”) are valid for 30 days, sidered obsolete and may be destroyed by Seller formed therein and without regard to conflicts of laws
except as explicitly otherwise stated therein, and do after two consecutive years have elapsed without principles. Buyer irrevocably agrees and consents to
not include any sales, use, or other taxes or duties Buyer ordering the items manufactured using such the exclusive jurisdiction and venue of the courts of
unless specifically stated. Subject to credit approval, property. Seller shall not be responsible for any loss Cuyahoga County, Ohio with respect to any dispute,
payment for all purchases is due 30 days from the or damage to such property while it is in Seller’s pos- controversy or claim arising out of or relating to this
date of invoice (or such date as may be specified by session or control. agreement.
Seller’s Credit Department). Unpaid invoices beyond 9. Special Tooling. A tooling charge may be 18. Indemnity for Infringement of Intellectual
the specified payment date incur interest at the rate of imposed for any special tooling, including without lim- Property Rights. Seller is not liable for infringement
1.5% per month or the maximum allowable rate under itation, dies, fixtures, molds and patterns, acquired of any patents, trademarks, copyrights, trade dress,
applicable law. to manufacture Products. Such special tooling shall trade secrets or similar rights except as provided in
3. Shipment; Delivery; Title and Risk of Loss. be and remain Seller’s property notwithstanding pay- this Section. Seller will defend and indemnify Buyer
Unless otherwise specified by Seller, shipment of all ment of any charges by Buyer. In no event will Buyer against allegations of infringement of U.S. patents,
Products shall be FOB Seller’s facility, or if interna- acquire any interest in apparatus belonging to Seller U.S. trademarks, copyrights, trade dress and trade
tional, EXW Seller’s facility (INCOTERMS 2010). All which is utilized in the manufacture of the Products, secrets (“Intellectual Property Rights”). Seller will
delivery dates are approximate. Seller is not respon- even if such apparatus has been specially converted defend at its expense and will pay the cost of any
sible for damages resulting from any delay. Regard- or adapted for such manufacture and notwithstand- settlement or damages awarded in an action brought
less of the manner of shipment, delivery occurs and ing any charges paid by Buyer. Unless otherwise against Buyer based on an allegation that a Product
title and risk of loss or damage pass to Buyer, upon agreed, Seller has the right to alter, discard or other- sold pursuant to this agreement infringes the Intellec-
placement of the Products in shipment with the car- wise dispose of any special tooling or other property tual Property Rights of a third party. Seller’s obliga-
rier at Seller’s facility. Unless otherwise stated, Seller in its sole discretion at any time. tion to defend and indemnify Buyer is contingent on
may exercise its judgment in choosing the carrier and 10. Buyer’s Obligation; Rights of Seller. To secure Buyer notifying Seller within ten (10) days after Buyer
means of delivery. No deferment of shipment at Buy- payment of all sums due or otherwise, Seller retains becomes aware of such allegations of infringement,
ers’ request beyond the respective dates indicated a security interest all Products delivered to Buyer and and Seller having sole control over the defense of any
will be made except on terms that will indemnify, this agreement is deemed to be a Security Agree- allegations or actions including all negotiations for
defend and hold Seller harmless against all loss and ment under the Uniform Commercial Code. Buyer settlement or compromise. If a Product is subject to a
additional expense. Buyer shall be responsible for authorizes Seller as its attorney to execute and file on claim that it infringes the Intellectual Property Rights
any additional shipping charges incurred by Seller Buyer’s behalf all documents Seller deems necessary of a third party, Seller may, at its sole expense and
due to Buyer’s acts or omissions. to perfect its security interest. option, procure for Buyer the right to continue using
4. Warranty. Seller warrants that the Products 11. Improper use and Indemnity. Buyer shall indem- the Product, replace or modify the Product so as to
sold hereunder shall be free from defects in material nify, defend, and hold Seller harmless from any claim, make it noninfringing, or offer to accept return of the
or workmanship for a period of twelve months from liability, damages, lawsuits, and costs (including Product and return the purchase price less a reason-
the date of delivery or 2,000 hours of normal use, attorney fees), whether for personal injury, property able allowance for depreciation. Notwithstanding the
whichever occurs first. All prices are based upon the damage, patent, trademark or copyright infringement foregoing, Seller is not liable for claims of infringe-
exclusive limited warranty stated above, and upon the or any other claim, brought by or incurred by Buyer, ment based on information provided by Buyer, or
following disclaimer: DISCLAIMER OF WARRANTY: Buyer’s employees, or any other person, arising out directed to Products delivered hereunder for which
THIS WARRANTY COMPRISES THE SOLE AND of: (a) improper selection, improper application or the designs are specified in whole or part by Buyer,
ENTIRE WARRANTY PERTAINING TO PRODUCTS other misuse of Products purchased by Buyer from or infringements resulting from the modification,
PROVIDED. SELLER DISCLAIMS ALL OTHER Seller; (b) any act or omission, negligent or otherwise, combination or use in a system of any Product sold
WARRANTIES, EXPRESS AND IMPLIED, INCLUD- of Buyer; (c) Seller’s use of patterns, plans, drawings, hereunder. The foregoing provisions of this Section
ING DESIGN, MERCHANTABILITY AND FITNESS or specifications furnished by Buyer to manufacture constitute Seller’s sole and exclusive liability and
FOR A PARTICULAR PURPOSE. Product; or (d) Buyer’s failure to comply with these Buyer’s sole and exclusive remedy for infringement of
5. Claims; Commencement of Actions. Buyer shall terms and conditions. Seller shall not indemnify Intellectual Property Rights.
promptly inspect all Products upon receipt. No claims Buyer under any circumstance except as otherwise 19. Entire Agreement. This agreement contains the
for shortages will be allowed unless reported to the provided. entire agreement between the Buyer and Seller and
Seller within 10 days of delivery. No other claims 12. Cancellations and Changes. Buyer may not constitutes the final, complete and exclusive expres-
against Seller will be allowed unless asserted in writ- modify or cancel any order for any reason, except sion of the terms of sale. All prior or contemporane-
ing within 30 days after delivery. Buyer shall notify with Seller’s written consent and upon terms that will ous written or oral agreements or negotiations with
Seller of any alleged breach of warranty within 30 indemnify, defend and hold Seller harmless against all respect to the subject matter are herein merged.
days after the date the defect is or should have been direct, incidental and consequential loss or damage. 20. Compliance with Law, U. K. Bribery Act and
discovered by Buyer. Any claim or action against Seller may change product features, specifications, U.S. Foreign Corrupt Practices Act. Buyer agrees
Seller based upon breach of contract or any other designs and availability with notice to Buyer. to comply with all applicable laws and regulations,
theory, including tort, negligence, or otherwise must 13. Limitation on Assignment. Buyer may not including both those of the United Kingdom and
be commenced within 12 months from the date of the assign its rights or obligations under this agreement the United States of America, and of the country or
alleged breach or other alleged event, without regard without the prior written consent of Seller. countries of the Territory in which Buyer may operate,
to the date discovered. 14. Force Majeure. Seller does not assume the including without limitation the U. K. Bribery Act, the
6. LIMITATION OF LIABILITY. IN THE EVENT OF risk and is not liable for delay or failure to perform U.S. Foreign Corrupt Practices Act (“FCPA”) and the
A BREACH OF WARRANTY, SELLER WILL, AT ITS any of Seller’s obligations by reason of events or U.S. Anti-Kickback Act (the “Anti-Kickback Act”), and
OPTION, REPAIR OR REPLACE A DEFECTIVE PROD- circumstances beyond its reasonable control (here- agrees to indemnify and hold harmless Seller from
UCT, OR REFUND THE PURCHASE PRICE WITHIN inafter “Events of Force Majeure”). Events of Force the consequences of any violation of such provisions
A REASONABLE PERIOD OF TIME. IN NO EVENT Majeure shall include without limitation: accidents, by Buyer, its employees or agents. Buyer acknowl-
IS SELLER LIABLE FOR ANY SPECIAL, INDIRECT, strikes or labor disputes, acts of any government or edges that it is familiar with the provisions of the U. K.
INCIDENTAL OR CONSEQUENTIAL DAMAGES government agency, acts of nature, delays or failures Bribery Act, the FCPA and the Anti-Kickback Act, and
ARISING OUT OF, OR AS THE RESULT OF, THE in delivery from carriers or suppliers, shortages of certifies that Buyer will adhere to the requirements
SALE, DELIVERY, NON-DELIVERY, SERVICING, materials, or any other cause beyond Seller’s reason- thereof. In particular, Buyer represents and agrees
USE OR LOSS OF USE OF THE PRODUCTS OR able control. that Buyer will not make any payment or give anything
ANY PART THEREOF, OR FOR ANY CHARGES OR 15. Waiver and Severability. Failure to enforce any of value, directly or indirectly to any governmental
EXPENSES OF ANY NATURE INCURRED WITH- provision of this agreement will not invalidate that official, any foreign political party or official thereof,
OUT SELLER’S WRITTEN CONSENT, EVEN IF provision; nor will any such failure prejudice Seller’s any candidate for foreign political office, or any com-
SELLER HAS BEEN NEGLIGENT, WHETHER IN right to enforce that provision in the future. Invalida- mercial entity or person, for the purpose of influenc-
CONTRACT, TORT OR OTHER LEGAL THEORY. tion of any provision of this agreement by legislation ing such person to purchase products or otherwise
IN NO EVENT SHALL SELLER’S LIABILITY UNDER or other rule of law shall not invalidate any other pro- benefit the business of Seller.
ANY CLAIM MADE BY BUYER EXCEED THE PUR- vision herein. The remaining provisions of this agree-
CHASE PRICE OF THE PRODUCTS. ment will remain in full force and effect.
7. User Responsibility. The user, through its own 16. Termination. Seller may terminate this agree- For Products sold by CIC Group Aftermarket
analysis and testing, is solely responsible for mak- ment for any reason and at any time by giving Buyer Division, the following additional terms apply:
ing the final selection of the system and Product and thirty (30) days advance written notice. Seller may • Payment Terms: Subject to credit approval,
assuring that all performance, endurance, mainte- immediately terminate this agreement, in writing, 1% 10th-Prox; Net 30 days
nance, safety and warning requirements of the appli- if Buyer: (a) commits a breach of any provision of • Freight prepaid on $1,500 net order value
cation are met. The user must analyze all aspects of this agreement (b) appointments a trustee, receiver
© 2012 Parker Hannifin Corporation. Catalog E-1 / 72012

Parker Hannifin Corporation


Climate and Industrial Controls Group
2445 South 25th Avenue • Broadview, IL 60155-3891 USA
phone 800 742 2681 • fax 800 241 2872
www.parker.com/coolparts