Filtros KLT
Filtros KLT
23
KLT/KLS Series
Tank Top Return Line Filters
Applications for KLT and KLS Filters
• Mobile Equipment
• Construction, Refuse
• Industrial Power Units
• Machine Tool
• Oil Field
Parker’s new KLS /KLT Tank Top Return
Line Filters are ideally suited for
Mobile and Industrial high to medium
flow return applications, from 30 to
120 GPM. This cost-effective, in-tank
filter series provides maximum flow
and dirt holding capacity for longer
filter element life in a simple, easy-to-
install-and-service assembly.
24
KLT/KLS Series
Specifications
¼“ NPT THREAD
½“ NPT CONDUIT CONNECTION
B
18.0 (457)
WIRE LEADS
COMMON BLACK
N.O. : RED
N.C. : GREEN
1.89 (48)
18 TO 22 PSI
(YELLOW FIELD) 22 TO 60 PSI
(RED FIELD) 1.06
(27)
THREAD A
C 2.08
(53) .55 (14) SQ.
D
HOLE IN RESERVOIR
25
KLT Series
Dimensional Drawings
KLT 2 / KLT 4 KLT 7 / KLT 8
2.68 (68) 3.54 (90)
4.72 (120)
TYP 6.54 (166)
SAE-16 STRAIGHT TYP.
THREAD O-RING PORT SAE-24 STRAIGHT THREAD
O-RING PORT
.35 (9) DIA. MOUNTING HOLES .43 (11) DIA. MOUNTING HOLES
(4 PLACES) ON 4.96 (126) B.C. (4 PLACES) ON 6.89 (175) B.C.
RECOMMENDED HEAD TO TANK RECOMMENDED HEAD TO TANK
TORQUE: 11 FT-LB (15 N-m) TORQUE: 30 FT-LB (40 N-m)
C
C
MIN. SERVICE CLEARANCE ¼ NPT PLUGGED GAUGE PORT(S)
MIN. SERVICE
¼ NPT PLUGGED (3 PLACES)
CLEARANCE
GAUGE PORT(S)
(3 PLACES)
3.66 (93)
2.83 (72) 1.42 (36)
1.10 (28)
D
RESERVOIR
CUTOUT
D DIAMETER
RESERVOIR
CUTOUT
DIAMETER
26
KLT Series
Dimensional Drawings
KLS 7 / KLS 8
3.38 (86)
.43 (11) DIA. MOUNTING HOLES
(4 PLACES) ON 6.25 (158.8) B.C.
RECOMMENDED HEAD TO
TANK TORQUE: 30 FT-LB (40 N-m)
6.76 (172)
¼ NPT
3.62 (92) PLUGGED
GAUGE PORTS
1.62 (41) (2 PLACES)
D
RESERVOIR
CUTOUT
DIAMETER
27
KLT Series
Dimensional Drawing
KLT with 2” Port
3.062
REF.
5/16-18 UNC-2B 1/4" NPT 1.531
TAP THRU. 4 PLC'S 3 PLC'S REF.
.844
REF.
1.688
3.190 REF.
REF.
1.46
REF.
Ø.433 4 PLC'S
EQUALLY SPACED 1/2-13 UNC-2B
28
KLT Series
KLT-2 Element Performance
Efficiency 8VeVX^in
Beta Rating Efficiency % EH>9 76G
10000 '*#%
&#*%
2Q 5Q
5Q '%#%
&#'*
1000 99.9
10Q &*#%
&#%%
*#%
20 95.0 %#'*
%#% %#%%
% * &% &* '% '*
2 50.0 <gVbh
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 15 gpm to 25 psid terminal - 10 mg/L BUGL
'%
&#'
&* &#%
%#-
EH>9
76G
&%
%#+
%#)
*
%#'
% %#%
% * &% &* '% '* (%
<EB
29
KLT Series
KLT-4 Element Performance
Efficiency 8VeVX^in
Beta Rating Efficiency % EH>9 76G
10000 '*#%
&#*%
2Q 5Q
5Q '%#%
&#'*
1000 99.9
10Q &*#% &#%%
*#%
20 95.0 %#'*
%#% %#%%
% * &% &* '% '* (% (* )% )* *%
2 50.0 <gVbh
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 30 gpm to 25 psid terminal - 10 mg/L BUGL
'%
&#'
&* &#%
%#-
EH>9
76G
&%
%#+
%#)
*
%#'
% %#%
% &% '% (% )% *%
<EB
30
KLT/KLS Series
KLT/KLS-7 Element Performance
Efficiency
8VeVX^in
Beta Rating Efficiency % EH>9 76G
10000 '*#%
&#*%
2Q 5Q
5Q '%#%
&#'*
1000 99.9
10Q &*#%
&#%%
*#%
20 95.0 %#'*
%#% %#%%
% '% )% +% -% &%% &'%
<gVbh
2 50.0
0 4 8 12 16 20
Micron Size (c)
Multipass tests run @ 50 gpm to 25 psid terminal - 10 mg/L BUGL
AEB
% *% &%% &*% '%% '*% (%% (*%
'%
&#'
&* &#%
%#-
EH>9
76G
&%
%#+
%#)
*
%#'
% %#%
% '% )% +% -% &%%
<EB
31
KLT/KLS Series
KLT/KLS-8 Element Performance
Efficiency
8VeVX^in
Beta Rating Efficiency % EH>9 76G
10000 '*#%
&#*%
2Q 5Q
5Q '%#%
&#'*
1000 99.9
10Q &*#%
&#%%
*#%
20 95.0 %#'*
%#% %#%%
% '% )% +% -% &%% &'% &)%&+% &-% '%%
<gVbh
2 50.0
0 4 8 12 16 20
Micron Size (c)
AEB
% &%% '%% (%% )%%
&%
%#+
-
%#*
+ %#)
EH>9
76G
%#(
)
%#'
'
%#&
% %#%
% '% )% +% -% &%% &'%
<EB
32
KLT/KLS Series
KLT with 2” Port - Element Performance
Efficiency
Beta Rating Ef f ic iency %
10000
2Q
5Q
10Q
1000 99.9
20Q 99.5
200
100 99.0
20 95.0
2 50.0
0 4 8 12 16 20
Micron Siz e (c)
20.0
150SUS
1.2
16.0
2Q
1.0
PSID
BAR
12.0
0.8
5Q
0.6
8.0
10Q
0.4
4.0
20Q 0.2
0.0 0.0
0 40 80 120 160 200
GPM
33
KLT and KLS Series
Operating and Maintenance Instructions
A. Mounting Parts List
1. Standard mounting.
a. Cut proper size hole in the top of the reservoir. Part
Index Description Quantity
b. Drill holes for studs within the proper bolt circle. Number
c. Set the filter into the cutout hole and secure with 1 Cover Assembly (Includes Cover o-ring)
proper size bolts, nuts and lock washers.
d. Torque nuts in accordance with drawing. KLT2/KLT4 937049 1
2. Mounting procedure using weld plate. KLT7/KLT8 937047 1
a. Rough cut proper size hole in the top of reservoir.
b. Weld the weld plate concentric to the rough cut KLS7/KLS8 937048 1
hole. 2 Cover o-ring
c. Mount the filter onto the studs and secure with
KLT2/KLT4, Nitrile N72239 1
nuts and lock washers.
d. Torque nuts in accordance with drawing. KLT2/KLT4, FKM V72239 1
3. Utilize proper fittings. KLT7/KLT8, Nitrile N72251 1
B. Start-Up KLT7/KLT8, FKM V72251 1
1. Check for and eliminate leaks upon system start-up.
2. Check differential pressure indicator, if installed, to KLS7/KLS8, Nitrile N72251 1
monitor element condition. KLS7/KLS8, FKM V72251 1
C. Service 3 Element (see How to Order page)
1. An element must be serviced when the indicator
indicates service is required. 4 Filter Head (Includes gauge plugs & studs)
NOTE: If the filter is not equipped with an indicator, KLT2/KLT4 (S16) 5841216 1
the element should be serviced according to machine KLT7/KLT8 (S24) 5841224 1
manufacturer’s instructions.
KLS7/KLS8 (S24) 937318 1
KLS7/KLS8 (2” Flange) 942157 1
5 Tank Gasket
1 KLT2/KLT4 108x98x5.5B 1
KLT7/KLT8 152x136x6B 1
KLS7/KLS8 (O-Ring) N72355 (C.F.) 1
Not
Weld Plate
2 Shown
KLT2/KLT4 300041 1
KLT7/KLT8 300042 1
Not
Shown Pressure Switch NS-1C-19R/EL 1
Not
Shown Pressure Gauge 936913 1
34
KLT and KLS Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
Replacement Elements
35