Fe ature s
■ Accuracy ≤ 0.5 % of span limit point calibration (0.25 % of span best fit straight line)
■ Broad selection of pressure ranges, engineering units in psi, bar, MPa, kg/cm2, and kPa.
Pressure references: gauge (vacuum, positive, compound) and absolute
■ Available with a variety of electrical connections and output signals
Features
Contents Swagelok industrial
pressure transducers
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 provide electronic
monitoring of
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
system pressure for
Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . 2 general industrial
applications,
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 including hazardous
locations.
Model Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . 3 ■ Stainless steel
construction with
Transducer Models
robust, compact
S Model: Standard Industrial . . . . . . . . . . . . . . . . . . 4 design that resists
pressure spikes, shock, and vibration
E Model: Explosion-Proof . . . . . . . . . . . . . . . . . . . . 6 ■ Variety of pressure ranges, process connections, electrical
connections, and output signals for system versatility
T Model: Intrinsically Safe . . . . . . . . . . . . . . . . . . . . 8
■ Thin film and piezoresistive sensor technology for
Pressure Range Designators . . . . . . . . . . . . . . . . . . . . . 10 repeatability, reliability, and stability
■ Temperature-compensated to ensure accuracy and long-
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 term stability when exposed to temperature variations
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ■ Available in flush diaphragm version for use with viscous
fluids and slurries.
Accessories ■ Wiring protection against reverse polarity and short circuit
on the instrument side
Attachable Indicator Display. . . . . . . . . . . . . . . . . . . 14
A B C D E
PTI - S - NG160 - 1 5 AO - E
A Pressure Range D Process End Connection E Options (See pages 3 and 14.)
See pages 10 and 11. Internal Diaphragm Type For multiple options, add designators in
AO = 1/4 in. male NPT alphabetical order.
B Output Signal AP = 1/2 in. male NPT➀ A = Special cleaning, ASME B40.1
1 = 4 to 20 mA AQ = 1/4 in. Swagelok tube adapter Level IV➀
2 = 0 to 5 V (dc) BG = 3/8 in. Swagelok tube adapter B = Accuracy ≤ 0.25 % LPC of span
3 = 0 to 10 V (dc) AR = 1/2 in. Swagelok tube adapter (0.125 % BFSL) (for pressure
AS = 6 mm Swagelok tube adapter ranges ≥ 0.25 bar [(3.6 psi,
BH = 10 mm Swagelok tube adapter 0.025 MPa, 0.25 kg/cm2, 25 kPa])
C Electrical Connector
AT = 12 mm Swagelok tube adapter C =11-Point Certificate of Calibration
1 =4-pin circular connector, M12 3 1 traceable to DKD, EN 10204 3.1
(IP67/NEMA 4) AV = G1/4B EN (1/4 RG)➁
D =General Material Certificate of
2 =Direct-wire 4 ft (1.5 m) flying lead AW = G1/2B EN (1/2 RG)➀➁
Compliance, EN 10204 2.2
(IP67/NEMA 4) AX = G1/4B PF (1/4 RJ)➂
E = Material Test Certificate,
3 =Bendix 4-pin MIL plug (IP67/ AZ = G1/2B PF (1/2 RJ)➂
EN 10204 3.1, heat code traceable
NEMA 4) BD = R1/4 PT (1/4 ISO 7 taper)
F = Certificate of Accuracy,
5 =L-plug, PG9 cable gland, BE = R1/2 PT (1/2 ISO 7 taper) EN 10204 2.2
DIN EN175301-803 (IP65/NEMA 5) Flush Diaphragm Type R =Mounted cooling element, –40 to
6 =L-plug, 1/2 in. NPT female BV = G1/2B EN flush diaphragm 302°F (–40 to 150°C) (3 fins)➁
conduit, DIN EN175301-803 (IP65/ BJ = G1B EN flush diaphragm S =Mounted cooling element, –40 to
NEMA 5) 392°F (–40 to 200°C) (5 fins)➁
➀ Refers to cooling element process connection
7 =Direct-wire 4 ft (1.5 m) flying lead when ordering mounted cooling element T = 9 ft (2.7 m) cable➂
(IP68/NEMA 6) zero and span (designator R or S).
Y = 16 ft (4.9 m) cable➂
nonadjustable ➁ Can be used with Swagelok RG adapter
fittings. Z = 32 ft (9.8 m) cable➂
8 =Bendix 6-pin MIL plug (IP67/ ➂ Can be used with Swagelok RJ adapter
NEMA 4) fittings. Flush Diaphragm Type Only
U =Integral cooling element (2 fins)
(requires process end connection
BV or BJ and EPDM or fluorocarbon
FKM/FPM O-ring [option W or X])
V =Alloy C-22 flush diaphragm (for
pressure ranges ≥ 0.25 bar [3.6 psi,
0.025 MPa, 0.25 kg/cm2, 25 kPa];
requires process end connection
BV or BJ)
W = EPDM O-ring
X = Fluorocarbon FKM/FPM O-ring
➀ Available only with positive pressure ranges
≥ 0.40 bar (5.8 psi, 0.04 MPa, 0.41 kg/cm2,
40 kPa); not available with process end
connections BV or BJ; not available with
options R, S, U, W, or X. When ordered with a
piezoresistive sensor range, a halocarbon fluid
is included; for oxygen applications, maximum
media temperature is 140°F (60°C).
➁ Available only with process end connections
AP and AW; transducer-to-cooling element
connection is G1/2B EN (1/2 RG). Cooling
element is not field removable.
➂ Available only with direct-wire electrical
connectors; select electrical connector 2 or 7.
6 Industrial Pressure Transducers
E Model: Explosion-Proof
The Swagelok E Model is specifically designed to meet
durability and performance demands of industrial applications
where explosion-proof ratings are required, such as wellhead
monitoring, refining, petrochemical, offshore oil and gas, and
gas measurement.
Features
■ Resistant to pressure spikes, vibration, and moisture intrusion
to IP67/NEMA 4X
E Model: Explosion-Proof
Ordering Information
Build an E Model transducer ordering number by adding the designators as shown below.
A B C D E
PTI - E - NG160 - 1 9 AQ - AE
A Pressure Range D Process End Connection E Options (See pages 3 and 14.)
See pages 10 and 11. Internal Diaphragm Type For multiple options, add designators in
AO = 1/4 in. male NPT alphabetical order.
B Output Signal AP = 1/2 in. male NPT A = Special cleaning, ASME B40.1
1 = 4 to 20 mA AQ = 1/4 in. Swagelok tube adapter Level IV➀
4 = 1 to 5 V (dc) BG = 3/8 in. Swagelok tube adapter C =11-Point Certificate of Calibration
AR = 1/2 in. Swagelok tube adapter traceable to DKD, EN 10204 3.1
C Electrical Connector AS = 6 mm Swagelok tube adapter D =General Material Certificate of
BH = 10 mm Swagelok tube adapter Compliance, EN 10204 2.2
9 = 1/2 in. male NPT conduit with
AT = 12 mm Swagelok tube adapter E = Material Test Certificate,
6 ft (1.8 m) shielded cable (IP67/
AV = G1/4B EN (1/4 RG)➀ EN 10204 3.1, heat code traceable
NEMA 4X)
AW = G1/2B EN (1/2 RG)➀ F = Certificate of Accuracy,
EN 10204 2.2
BD = R1/4 PT (1/4 ISO 7 taper)
T = 10 ft (3.0 m) cable
BE = R1/2 PT (1/2 ISO 7 taper)
Y = 20 ft (6.1 m) cable
Flush Diaphragm Type Z = 30 ft (9.1 m) cable
BV = G1/2B EN flush diaphragm
Flush Diaphragm Type Only
BJ = G1B EN flush diaphragm
V =Alloy C-22 flush diaphragm (for
➀ Can be used with Swagelok RG adapter
fittings. pressure ranges ≥ 0.25 bar [3.6 psi,
0.025 MPa, 0.25 kg/cm2, 25 kPa];
requires process end connection
BV or BJ)
W = EPDM O-ring
X = Fluorocarbon FKM/FPM O-ring
➀ Available only with positive pressure ranges
≥ 0.25 bar (3.6 psi, 0.025 MPa, 0.25 kg/cm2,
25 kPa); not available with process end
connections BV or BJ; not available with
options W or X. When ordered with a
piezoresistive sensor range, a halocarbon fluid
is included; for oxygen applications, maximum
media temperature is 140°F (60°C).
8 Industrial Pressure Transducers
A B C D E
PTI - T - AG160 - 1 7 AS - A
A Pressure Range D Process End Connection E Options (See pages 3 and 14.)
See pages 10 and 11. Internal Diaphragm Type For multiple options, add designators in
AO = 1/4 in. male NPT alphabetical order.
B Output Signal AP = 1/2 in. male NPT A = Special cleaning, ASME B40.1
1 = 4 to 20 mA AQ = 1/4 in. Swagelok tube adapter Level IV➀
BG = 3/8 in. Swagelok tube adapter B = Accuracy ≤ 0.25 % LPC of span
C Electrical Connector AR = 1/2 in. Swagelok tube adapter (0.125 % BFSL) (for pressure
1 =4-pin circular connector, M12 3 1 AS = 6 mm Swagelok tube adapter ranges ≥ 0.25 bar [3.6 psi,
(IP67/NEMA 4) BH = 10 mm Swagelok tube adapter 0.025 MPa, 0.25 kg/cm2, 25 kPa])
2 =Direct-wire 4 ft (1.5 m) flying lead AT = 12 mm Swagelok tube adapter C =11-Point Certificate of Calibration
(IP67/NEMA 4)➀ traceable to DKD, EN 10204 3.1
AV = G1/4B EN (1/4 RG)➀
3 =Bendix 4-pin MIL plug (IP67/ D =General Material Certificate of
AW = G1/2B EN (1/2 RG)➀
NEMA 4) Compliance, EN 10204 2.2
AX = G1/4B PF (1/4 RJ)➁
5 =L-plug, PG9 cable gland, E = Material Test Certificate,
AZ = G1/2B PF (1/2 RJ)➁
DIN EN175301-803 (IP65/NEMA 5) EN 10204 3.1, heat code traceable
BD = R1/4 PT (1/4 ISO 7 taper)
6 =L-plug, 1/2 in. NPT female F = Certificate of Accuracy,
BE = R1/2 PT (1/2 ISO 7 taper) EN 10204 2.2
conduit, DIN EN175301-803 (IP65/
NEMA 5) Flush Diaphragm Type R =Mounted cooling element, –40 to
7 =Direct-wire 4 ft (1.5 m) flying lead BV = G1/2B EN flush diaphragm 302°F (–40 to 150°C) (3 fins)➁
(IP68/NEMA 6) zero and span BJ = G1B EN flush diaphragm S =Mounted cooling element, –40 to
nonadjustable➀ ➀ Can be used with Swagelok RG adapter 392°F (–40 to 200°C) (5 fins)➁
8 =Bendix 6-pin MIL plug (IP67/
fittings. T = 9 ft (2.7 m) cable➂
➁ Can be used with Swagelok RJ adapter
NEMA 4) fittings.
Y = 16 ft (4.9 m) cable➂
A =Field case, M20 1.5 plastic Z = 32 ft (9.8 m) cable➂
cable gland, screw terminals (IP67/ Flush Diaphragm Type Only
NEMA 4X) U = Integral cooling element (2 fins)
B =Field case, M20 1.5 nickel- V =Alloy C-22 flush diaphragm (for
plated brass cable gland, screw pressure ranges ≥ 0.25 bar [3.6 psi,
terminals (IP67/NEMA 4X) 0.025 MPa, 0.25 kg/cm2, 25 kPa];
C =Field case, M20 1.5 stainless requires process end connection
steel cable gland, screw terminals BV or BJ)
(IP67/NEMA 4X) W = EPDM O-ring
D =Field case, 1/2 in. female NPT X = Fluorocarbon FKM/FPM O-ring
stainless steel conduit, screw
➀ Available only with positive pressure ranges
terminals (IP67/NEMA 4X) ≥ 0.25 bar (3.6 psi, 0.025 MPa, 0.25 kg/cm2,
➀ Ambient temperature 176°F (80°C) maximum. 25 kPa); not available with process end
connections BV or BJ; not available with
options R, S, U, W, or X. When ordered with a
piezoresistive sensor range, a halocarbon fluid
is included; for oxygen applications, maximum
media temperature is 140°F (60°C).
➁ Available only with process end connections
AP and AW; transducer-to-cooling element
connection is G1/2B EN (1/2 RG). Cooling
element is not field removable.
➂ Available only with direct-wire electrical
connectors; select electrical connector 2 or 7.
The surface temperature of the
T model transducer and cooling
element must not exceed the
maximum ambient temperature
required for the intrinsically safe
application.
10 Industrial Pressure Transducers
MPa kg/cm2
Over- Over-
Pressure Range Pressure Range
pressure Burst Sensor pressure Burst Sensor
Minimum Maximum Designator Rating Rating Type Minimum Maximum Designator Rating Rating Type
MPa Gauge Reference kg/cm2 Gauge Reference
0 MC0 0.1 0.2 0 CC0 1 2
0.06 MC.06 0.4 0.48 0.6 CC.6 4 4.8
0.15 MC.15➀ 1 1.2 1 CC1 5 6
Vacuum 0.3 MC.3 1.7 2 1.6 CC1.6➀ 10 12
Piezoresistive
–0.1 0.6 MC.6 3.5 4.2 Vacuum 3 CC3 17 20.5
Piezoresistive
0.9 MC.9 3.5 4.2 –1 4 CC4 17 20.5
1.5 MC1.5 8 9.6 5 CC5 35 42
2.5 MC2.5 5 25 9 CC9 35 42
0.04 MG.04➁ 0.2 0.24 15 CC15 80 96
0.06 MG.06 0.4 0.48 25 CC25 50 250
0.1 MG.1 0.5 0.6 0.6 CG.6 4 4.8
0.16 MG.16➀ 1 1.2 1 CG1 5 6
0.25 MG.25 1 1.2 1.6 CG1.6➀ 10 12
Piezoresistive
0.4 MG.4 1.7 2 2.5 CG2.5 10 12
0.6 MG.6 3.5 4.2 4 CG4➁ 17 20.5
Piezoresistive
1 MG1.0 3.5 4.2 6 CG6 35 42
1.6 MG1.6 8 9.6 10 CG10 35 42
0
2.5 MG2.5 5 25 16 CG16 80 96
4 MG4 8 40 0 25 CG25 50 250
6 MG6 12 40 40 CG40 80 400
10 MG10 20 80 60 CG60 120 400
16 MG16 32 100 Metal 100 CG100 200 800
25 MG25 50 120 thin film 160 CG160 320 1 000
40 MG40➂ 80 150 Metal
250 CG250 500 1 000
thin film
60 MG60➃➄ 120 150 400 CG400➂ 800 1 500
100 MG100 150 300 600 CG600➃➄ 1 200 1 500
1 000 CG1000 1 500 3 000
kPa
Over-
Pressure Range pressure Burst Sensor
Minimum Maximum Designator Rating Rating Type
kPa Gauge Reference
0 JC0 100 200
60 JC60➀ 400 480
Vacuum 300 JC300 1 700 2 000
Piezoresistive
–100 500 JC500 1 700 2 000
900 JC900 3 500 4 200
1 500 JC1500 8 000 9 600
40 JG40➁ 200 240
60 JG60 400 480
100 JG100 500 600
160 JG160➀ 1 000 1 200
250 JG250 1 000 1 200
Piezoresistive
400 JG400 1 700 2 000
600 JG600 3 500 4 200
1 000 JG1000 3 500 4 200
1 600 JG1600 8 000 9 600
0 2 500 JG2500 5 000 25 000
4 000 JG4000 8 000 40 000
6 000 JG6000 12 000 40 000
10 000 JG10K 20 000 80 000
16 000 JG16K 32 000 100 000
Metal
25 000 JG25K 50 000 120 000
thin film ➀ Minimum for G1/2 EN flush diaphragm; maximum for G1B EN flush diaphragm.
31 500 JG31.5K 50 000 120 000
➁ Minimum for E model.
40 000 JG40K➂ 80 000 150 000
➂ Maximum for 3/8 and 1/2 in.; 10 and 12 mm Swagelok tube adapter.
60 000 JG60K➃➄ 120 000 150 000
➃ Maximum for G1/2B EN flush diaphragm.
100 000 JG100K 150 000 300 000 ➄ Maximum for 1/4 in. and 6 mm Swagelok tube adapter and 1/4 in. NPT.
12 Industrial Pressure Transducers
Dimensions
Choose electrical connector, body type, Electrical Connector A
and process end connection, and add
together for overall height of transducer.
Dimensions, in inches (millimeters), are for
reference only and are subject to change.
Body B
1.06
(27.0)
3.31 (84.0)
2.03 1.87
(51.5) (47.6)
1.14 1.19
(29.0) (30.3) 2.60
1.00 (66.0)
(25.4)
1/2 in.
female
NPT
conduit
L Plug with PG9 L Plug with 1/2 in. Direct-Wire, Zero and Field Case,
Cable Gland Female Conduit Span Nonadjustable 1/2 in. Female NPT Conduit
B Body
S Model E Model T Model
A A 1/2 in.
male NPT
conduit
with
cable
1.06 1.06
(27.0) (27.0)
2.56
Plug Direct-Wire 3.30 (65.0) 2.13
(83.8) (54.0)
Body Model A
Style Accuracy in. (mm)
≤ 0.5 % 1.77 (45.0)
Plug
≤ 0.25 % 2.56 (65.0) 1.06 1.06
(27.0) (27.0)
Direct-wire ≤ 0.5 % 1.52 (38.5)
zero and span 1.06 Plug Field Case
≤ 0.25 % 2.13 (54.0) (27.0)
nonadjustable
Industrial Pressure Transducers 13
Dimensions
1/4 in. Male NPT 1/2 in. Male NPT 1/4 in. and 6 mm 3/8 in. and 10 mm 1/2 in. and 12 mm
and and Swagelok Tube Swagelok Tube Swagelok Tube
R1/4PT (ISO 7/1 Taper) R1/2PT (ISO 7/1 Taper) Adapter Adapter Adapter
G1/4B EN (1/4 RG) G1/2B EN (1/2 RG) G1/4B PF (1/4 RJ) G1/2B PF (1/2 RJ)
1.06 1.61
(27.0) (41.0)
hex hex
1.18 1.22 1.06 1.61
(29.9) (31.0) (27.0) (41.0)
1.79 hex 1.79 hex
(45.5) (45.5)
G1/2B EN Flush Diaphragm G1B EN Flush Diaphragm G1/2B EN Flush Diaphragm G1B EN Flush Diaphragm
with Integral Cooling with Integral Cooling
Element (2 Fins) Element (2 Fins)
3.23 3.27
(82.0) 3.62 (83.0) 3.66
1.06 (92.0) 1.06 (93.0)
(27.0) (27.0)
hex 1.06 hex 1.06
(27.0) (27.0)
hex hex
1/2 in. Male NPT with 1/2 in. Male NPT with G1/2B EN with Mounted G1/2 EN with Mounted
Mounted Cooling Element Mounted Cooling Element Cooling Element Cooling Element
–40 to 302°F (–40 to 150°C) –40 to 392°F (–40 to 200°C) –40 to 302°F (–40 to 150°C) –40 to 392°F (–40 to 200°C)
(3 Fins) (5 Fins) (3 Fins) (5 Fins)
14 Industrial Pressure Transducers
Options Accessories
Options are specified in transducer ordering numbers as shown in Ordering Attachable Indicator Display
Information for each model.
This LCD, 4-digit digital display
attaches directly to S model
EPDM and Fluorocarbon Alloy C-22 Diaphragm transducers using an L-plug connector
FKM/FPM O-Rings An alloy C-22 diaphragm is available and 4 to 20 mA output signals. The
EPDM or fluorocarbon FKM/FPM for flush diaphragm-type transducers display provides local readout of
O‑rings are available for flush with pressure ranges equal to or higher system pressure with simultaneous
diaphragm-type transducers. than 0.25 bar (3.6 psi, 0.025 MPa, signal transmission.
FKM is the designation for fluorinated 0.25 kg/cm2, 25 kPa).
elastomers as defined in ASTM D1418; Features
FPM is the international designation
Cables ■ Retrofits to transducers already in
defined in ISO/DIN 1629. Optional cable lengths are available. use
See Ordering Information for lengths ■ Adjustable and programmable with
available for each transducer model. flush-mounted keys below the front
cover
■ Rugged, compact plastic case meets
Cooling Elements IP65
Cooling elements extend the temperature Mounted cooling elements (option ■ CE conformity to 89/336/EEC
ratings of pressure transducers. designators R and S) have three and ■ Integrated self-diagnosing circuit
Integral cooling elements (option five cooling fins, respectively, and are monitoring
designator U) have two cooling fins available on S and T model transducers
with internal diaphragms. Performance
and are available on S and T model
transducers with flush diaphragms. See the graph below for cooling ■ Accuracy: 0.2% of span ± 1 digit
element selection information. ■ Scale adjustment: manually
programmed, menu driven
100 U Integral,
200 2 cooling fins Housing
R Mounted, ■ Material: ABS plastic
70 3 USA
cooling fins
150
S Mounted, Electrical Data
5 cooling fins ■ Input/output signal: 4 to 20 mA
40
100 ■ Voltage drop: 3 V
U R S
■ Maximum current rating: 40 mA
50 10 ■ Power supply: supplied by the 4 to
100 200 300 400 500 600
20 mA loop
Media Temperature, °F
Examples: For an ambient temperature of 150°F (65°C) and a media temperature of 250°F
(121°C), cooling elements U, R, and S would be suitable.
For an ambient temperature of 150°F (65°C) and a media temperature of 350°F
(176°C), only cooling elements R and S would be acceptable.
100 200 300 400 500 600
250
100
200
70
150
EURO
40
100
U R S
10 50
40 80 120 160 200 240 280
Industrial Pressure Transducers 15
Accessories
Remote Panel-Mount Display
The Swagelok compact remote panel meter digital
indicator can accept many types of signal inputs and
requires a supply voltage of 9 to 28 V (dc). The panel
meter is fully user adjustable and programmable. The
user-adjustable digital filtering improves readability
during rapid pressure changes.
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to
change.
2.56
(65.0)
1.89 Panel Cutout
(48.0)
0.28 0.35
(7.0) (9.0)
0.94 0.85
(24.0) (21.7)
1.77
(45.0)
Accessories
Cooling Elements Cables and Connectors
Thread-on cooling element adapters
are available for use with G1/2B EN
(1/2 RG) process connections on
S model transducers only. These
cooling adapters increase the media
temperature ratings.
Ordering
Description Number
G1/2B EN (1/2 RG), 302°F (150°C) media,
PTI-CE150-AW
86°F (30°C) ambient (3 fins)
G1/2B EN (1/2 RG), 392°F (200°C) media,
PTI-CE200-AW
86°F (30°C) ambient (5 fins)
1/2 in. male NPT, 302°F (150°C) media,
PTI-CE150-AP
86°F (30°C) ambient (3 fins)
1/2 in. male NPT, 392°F (200°C) media, Mating Ordering
PTI-CE200-AP Connector Number
86°F (30°C) ambient (5 fins)
Bendix, 9 ft (3 m) cable,
PTU-MC-1
4-wire, UL listed➀
Bendix, no cable, 4-pin PTU-MC-2
M12 3 1, 6 ft (2 m) cable,
PTU-MC-3
straight, 4-wire
M12 3 1, 16 ft (5 m) cable,
PTU-MC-4
Weld Adapters straight, 4-wire
M12 3 1, 6 ft (2 m) cable,
Field-installed weld adapters 90° angled, 4-wire
PTU-MC-5
with factory machined
M12 3 1, no cable,
mating ports are available for PTU-MC-6
straight, 4-pin
the G1/2B EN and G1B EN M12 3 1, no cable,
flush diaphragm process PTU-MC-7
90° angled, 4-pin
connections. M12 3 1, 6 ft (2 m) cable,
PTU-MC-8
straight, 5-wire, UL listed➁
M12 3 1, 16 ft (5 m) cable,
PTU-MC-9
straight, 5-wire, UL listed➁
M12 3 1, 6 ft (2 m) cable,
PTU-MC-10
Ordering 90° angled, 5-wire, UL listed➁
Description Number M12 3 1, 16 ft (5 m) cable,
PTU-MC-11
G1/2B EN flush diaphragm weld adapter PTI-WA-BV 90° angled, 5-wire, UL listed➁
G1B EN flush diaphragm weld adapter PTI-WA-BJ M12 3 1, no cable,
PTU-MC-12
straight, 5-pin
M12 3 1, no cable,
PTU-MC-13
90° angled, 5-pin
M12 3 1 male, no cable,
PTU-MC-14
90° angled, 4-pin,
M12 3 1, 32 ft (10 m) cable,
PTU-MC-15
90° angled, 4-wire, UL listed➁
➀ UL style 2164/1061, temperature rating 176°F (80°C).
➁ UL style 20549/1061, temperature rating 176°F (80°C).