How To Clean Industrial Heat Exchangers
Match your cleaning method to the size and design of your heat exchanger.
For a Dramatic ‘Before’ and ‘After’
It’s easy to forget about heat exchangers. Perhaps half of all manufacturing heat exchangers are ignored until they have
problems. By the time these workhorses complain they can be so caked with deposits that you need to drill into the tubes
to clean them. Well designed maintenance routines and the proper equipment help you clean heat exchanger tubes quickly
and regularly, minimizing your risk of costly
breakdowns. Choose the right rotary tube cleaner
or an effective chemical cleaning system, and the
job’s done in no time.
Transformed
Before and after images show how chemical descaling can restore a heat exchanger to peak
operating efficiency and add years to its life - right in front of your eyes.
Choose Your Cleaning System
o The RAM-5SFVS rotary tube cleaner quickly cleans large heat exchangers.
o The PSM-500 tube cleaning drill clears out straight small-diameter tubes.
Straight shooter o It’s easiest to descale U-shaped tubes with a chemical descaling system. Or use
From soft deposits to solid clogs, the a rotary tube cleaner and clean half of the “U” with each pass.
PSM-500 clears out whatever’s blocking
your straight, small I.D. tubes. It’s fast
and effective.
MECHANICAL CLEANING
o Assess your heat exchanger to determine the cleaning
Tough on deposits, easy on equipment system best suited to its design and size (see box above).
ScaleBreak dissolves mineral deposits faster than other
liquid descalers. The biodegradable formula is safe for use
o Power down the heat exchanger and drain any liquid.
on steel, iron, brass, copper, plastic and rubber. Choose o ID the deposits in your tubes. A video scope gives you
ScaleBreak-SS for stainless steel surfaces.
inside intel so you know what you’re up against.
o Using the RAM-5SFVS or the PSM-500, run through a few
tubes and evaluate results with your scope.
o Adjust technique as needed and finish cleaning.
o Spot check, clean up and put the equipment back online.
Are we done yet?
A video scope gives a clear picture
of what you’re facing, and lets you
know when your tubes are clean. CHEMICAL CLEANING
o “Loop off” the heat exchanger from its water source.
o Use a descaling system to circulate ScaleBreak through
your unit. A Goodway rep can help you choose the best
Smart cleaner system for your heat exchanger.
The GDS-15-PH system o Run the descaler for about an hour, then check to see
continuously monitors pH levels
and injects additional chemicals whether descaling is complete. You will know that the
as needed during the cleaning scale is gone when the pH of the solution rises and/or the
cycle. Can be used on copper,
stainless steel and a variety of other ScaleBreak stops foaming.
materials.
o Clear out ScaleBreak; put the heat exchanger back online.
1.888.333.7467 WWW.GOODWAY.COM