Brochure Combined
Brochure Combined
COMPLETE
2800+
Channel Partners
7+ Lakh
Smiling Users Worldwide
500+
Service Points
SOLAR SOLUTIONS
Service by trained
Onsite service facility
professionals
SOUTH
AFRICA
Rajnish Sharma
Director
Smarten has experienced a substan al surge in the demand for its
products from more than 25 countries and has been leading the power
backup product expert space, have been recognised as one of the top
players in the country.
Backed by a team of over 300 technologists and dignitaries in power,
Smarten is now well-known across many countries in the world, including
India, Nepal, Bangladesh, Afghanistan, UAE, Nigeria and Benin.
PRODUCT SPECIFICATIONS
MODEL NAME 1050VA 2000VA 3500VA 5500VA 5500VA 7500VA 10000VA
MAINS MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery WUPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery WUPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
SINE WAVE 1050 VA - 10 KVA BATTERY
HOME UPS Battery Type LA / Tubular / SMF
DC input voltage 12V 24V 48V 96V 96V 120V
Battery Quantity 12V 100Ah to 220Ah 1 2 4 8 8 10
Bulk absorp on Voltage 14.8V 29.6V±0.2V 59.2V±0.4V 59.2V±0.4V 118V±0.4V 118V±0.4V 148V±0.4V
India’s Inverter Series which is need of every household! Float charging voltage 13.7V±0.2V 27.4V±0.2V 54.8V±0.4V 54.8V±0.4V 109.6V±0.4V 109.6V±0.4V 137V±0.4V
15 ampere current for Boost charging voltage for LA Battery 14.0V±0.2V
The technically advanced BRAVO Sine Wave Home UPS 28.0V±0.3V 56.0V±0.4V 56.0V±0.4V 112V±0.5V 112V±0.5V 140V±0.5V
faster ba ery charging Boost charging voltage for Tubular and SMF Ba ery 14.5V±0.2V 28.8V±0.3V 57.8V±0.4V 57.8V±0.4V 116V±0.5V 116V±0.5V 145V±0.5V
operates on mains and supplies power while charging the
Battery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
ba ery when mains supply is available. In case of a power Charging Current 100Ah-135Ah Setting
outage, Bravo transfers the en re load to its op mally charged Smart charging even (Input range 135VAC to 295VAC)
12A ± 2A
ba ery and supplies high quality sine wave AC power. during low voltage 90V* Charging Current 150Ah-220Ah Setting
15A ± 2A
(Input range 135VAC to 295VAC)
Apart from the highest quality components and Complete protec on from BACKUP MODE
engineering, what makes Bravo special is the inbuilt back feed and phase to Output voltage 220VAC ± 10%
charger that even charges zero volt zero gravity ba ery phase supply Output frequency 50Hz ± 0.2 Hz
as-well. In simple terms, it charges the dead ba ery and Output waveform Pure Sine Wave ≤ 5% THD
get it recover slowly that provides the user uninterrupted Compa ble with all No Load current <1.8A
supply. type ba ery Discharging current @ full load 50A ± 2A 60A ± 2A 90A ± 2A 45A ± 2A 66A ± 2A 66A ± 2A
Low Battery Warning 10.8V±0.2V 21.6V±0.2V 43.2V±0.4V 43.2V±0.4V 86.4V±0.4V 86.4V±0.4V 108V±0.4V
Low Battery Cut 10.4V±0.2V 20.8V±0.2V 41.6V±0.4V 41.6V±0.4V 83.2V±0.4V 83.2V±0.4V 104V±0.4V
Change over time UPS mode < 10msec < 4msec
Change over time WUPS mode < 25msec
PROTECTIONS
Overload in backup mode Yes provided, system will give indication at 101% load
Short Circuit in Backup Mode System will shutdown a er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains MCB will trip
Back feed System will shutdown in case of back feed and there is no retry
Over temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse Battery DC fuse will blown
ALARMS
Audible beep for Overload, Short Circuit, Back feed, Low Ba ery, Over Temperature,
LED BULB TULLU PUMP JUICER MIXER PC LED TV Buzzer
Mains Fuse blown / MCB Trip
ENVIRONMENT
Operating Temperature 0°C to 50°C
Storage Temperature 0°C to 50°C
Operating Rela ve Humidity 90% Non-Condensing
WEIGHT AND DIMENSIONS
Dimensions in mm (LxWxH) 355x355x195 425x315x385 425x315x385 518x415x515 575x415x640
Weight (Kg) 9.35 18.5 24.5 45 50 72 75
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 875VA 1075VA 1250VA 2050VA
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery WUPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery WUPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
PURE SINE WAVE BATTERY
HOME UPS
875 VA - 2050 VA Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2
Bulk absorp on Voltage 14.8V 29.6V±0.2V
Bravo Eco is a Pure Sine Wave Home UPS that comes Float charging voltage 13.7V±0.2V 27.4V±0.2V
with its unique features. The product is a great Great power saving Boost charging voltage for LA Battery 14.0V±0.2V 28.0V±0.2V
companion for people who are looking to run appliances up to 30% Boost charging voltage for Tubular and SMF Battery 14.5V±0.2V 29.0V±0.2V
Ba ery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
with small applications.
Charging Current 100Ah-135Ah Se ng (Input range 135VAC to 295VAC) 12A ± 2A
The product has high efficiency of converting battery Battery charges at Charging Current 150Ah-220Ah Se ng (Input range 135VAC to 295VAC) 15A ± 2A
load to AC load results into long backup. The whole very low voltage till 90V BACKUP MODE
Output voltage 220VAC±10%
process helps the customer to provide uninterrupted
Output frequency 50Hz ± 0.2 Hz
power supply with low electricity bill & more savings.
12% to 15% more backup Output waveform Pure Sine Wave ≤ 5% THD
Bravo Eco gives 12%-15% extra backup to have smooth No Load current <1.8A
Discharging current @ full load 40A ± 2A 52A ± 2A 60A ± 2A 60A ± 2A
experience for domestic and commercial purposes.
Low Battery Warning 10.6V±0.2V 10.8V±0.2V 21.6V±0.2V
User friendly interface Low Battery Cut 10.4V±0.2V 20.8V±0.2V
Change over time UPS mode < 10msec
Change over time WUPS mode < 25msec
PROTECTIONS
Overload in backup mode Yes provided, system will give indica on at 101% load
Short Circuit in Backup Mode System will shutdown a er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains Fuse will blown
Back feed System will shutdown in case of back feed and there is no retry
Over temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse Ba ery DC fuse will blown
ALARMS
Audible beep for Overload, Short Circuit, Back feed, Low Ba ery,
Buzzer
Over Temperature, Mains Fuse blown / MCB Trip
ENVIRONMENT
LED BULB TULLU PUMP JUICER MIXER PC Opera ng Temperature 0°C to 50°C
Storage Temperature 0°C to 50°C
Opera ng Rela ve Humidity 90% Non-Condensing
WEIGHT AND DIMENSIONS
Dimensions in mm (LxWxH) 301×297×160 355x355x195 403x392x227
Weight (Kg) 7.7 8.8 9.8 16
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 1075VA 1250VA 1500VA 2050VA 2525VA 3050VA
MAINS MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery WUPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery WUPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
BATTERY
1075VA - 3050VA Battery Type LA / Tubular / SMF
DC input voltage 12V 24V
Battery Quantity 12V 100Ah to 220Ah 1 2
Bulk absorp on Voltage 14.8V 29.6V±0.2V
Float charging voltage 13.7V±0.2V 27.4V±0.2V
When Performance comes with style! Boost charging voltage for LA Battery 14.0V±0.2V
WUPS
WUPS/UPS Selectable 28.0V±0.3V
The smartly designed Nova Home UPS comes with LED Boost charging voltage for Tubular and SMF Ba ery 14.5V±0.2V 28.8V±0.3V
UPS Switch
Battery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
Bu ons that operates on mains and supplies power
Charging Current 100Ah-135Ah Setting
while charging the ba ery when mains supply is Recover Deep Discharge (Input range 135VAC to 295VAC)
12A ± 2A
available. In case of a power outage, Nova transfers the Battery Even Zero Volt Charging Current 150Ah-220Ah Setting
Gravity 15A ± 2A
en re load to its op mally charged ba ery and supplies (Input range 135VAC to 295VAC)
high quality AC power. BACKUP MODE
Smart Charging Even Output voltage 220VAC ± 10%
Apart from the highest quality components and Output frequency 50Hz ± 0.2 Hz
During Low Voltage 90V*
engineering, what makes Nova special is the inbuilt Output waveform Pure Sine Wave ≤ 5% THD
charger that even charges zero volt zero gravity ba ery No Load current <1.8A
as-well. In simple terms, it charges the dead ba ery and Compatible with all Discharging current @ full load 50A ± 2A 60A ± 2A 70A ± 2A 60A ± 2A 70A ± 3A 90A ± 3A
Type Battery* Low Battery Warning 10.8V±0.2V 21.6V±0.2V
get it recover slowly that provides the user uninterrupted
Low Battery Cut 10.4V±0.2V 20.8V±0.2V
supply. Change over time UPS mode < 10msec
Change over time WUPS mode < 25msec
PROTECTIONS
Overload in backup mode Yes provided, system will give indication at 101% load
Short Circuit in Backup Mode System will shutdown a er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains MCB will trip
Back feed System will shutdown in case of back feed and there is no retry
Over temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse Battery DC fuse will blown
ALARMS
Audible beep for Overload, Short Circuit, Back feed, Low Ba ery, Over Temperature,
LED BULB TULLU PUMP JUICER MIXER PC LED TV Buzzer
Mains Fuse blown / MCB Trip
ENVIRONMENT
Operating Temperature 0°C to 50°C
Storage Temperature 0°C to 50°C
Operating Rela ve Humidity 90% Non-Condensing
WEIGHT AND DIMENSIONS
Dimensions in mm (LxWxH) 355x355x195 410x390x235 425x315x335
Weight (Kg) 8.8 9.8 10.3 16 17.8 20.5
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 1100VA 2675VA 3250VA 4000VA 5500VA 6000VA 7500VA 10000VA 15000VA 20000VA
MAINS INPUT MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery W.UPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery W.UPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Mains Charging Enable/Disable Yes Provided, you can set by front switch
Frequency Output in Mains Mode Same as input
BATTERY
Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V 48V 72V 96V 120V 180V 240V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2 4 6 8 10 15 20
Float charging voltage 13.7V±0.2V 27.4V±0.2V 54.8V±0.2V 82.2V±0.2V 109.6V±0.4V 137V±0.4V 205.5V±0.4V 274V±0.4V
Boost charging voltage for LA Ba ery 14V±0.2V 28V±0.3V 56V±0.4V 84V±0.2V 112V±0.4V 140V±0.4V 210V±0.4V 280V±0.4V
Boost charging voltage for Tubular and SMF Battery 14.5V±0.2V 29.0V ± 0.2V 57.8V±0.4V 87V±0.2V 116V±0.4V 145V±0.4V 217.5V±0.4V 290.5V±0.4V
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 1100VA 2675VA 3075VA 4000VA 5500VA 7500VA 10000VA
MAINS INPUT MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery W.UPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery W.UPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Mains Charging Enable/Disable Yes Provided, you can set by front switch
Frequency Output in Mains Mode Same as input
BATTERY
Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V 48V 96V 120V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2 4 8 10
MPPT SOLAR POWER Float charging voltage
CONDITIONING UNIT
1100VA - 10KVA Boost charging voltage for LA Ba ery
13.7V±0.2V
14V±0.2V
27.4V±0.2V
28V±0.3V
54.8V±0.4V
59.2V±0.4V
109.6V±0.4V
118V±0.4V
137V±0.4V
140V±0.4V
Boost charging voltage for Tubular and SMF Battery 14.5V±0.2V 28.8V±0.3V 56.0V±0.4V 112V±0.4V 145V±0.4V
Bulk Absorption Ba ery Voltage 14.8V±0.2V 29.6±0.2V 58.0V±0.4V 116V±0.4V 148V±0.4V
Ba ery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
Charging Current By Grid 15A±3A
BACKUP MODE
Trendy+ is a Solar PCU which effectively can run heavy Output voltage 220VAC±10%
Output frequency
loads like 1HP Submersible, Photocopiers, Refrigerator, MPPT Based Advance Output waveform
50Hz ± 0.2 Hz
Pure Sine Wave ≤ 5% THD
washing machine etc., depending on their capacity. The Technology PCU No Load current <1.8A
Discharging current @ full load 62A ± 2A 70A ± 2A 90A ± 2A 60A ± 2A 90A ± 2A 66A ± 2A 66A ± 2A
product comes with LCD Display to easily understand Low Ba ery Warning 10.8V±0.2V 21.6V±0.2V 21.6V±0.2V 43.2V±0.4V 43.2V±0.4V 86.4V±0.4V 108V±0.4V
Low Ba ery Cut 10.4V±0.2V 20.8V±0.2V 20.8V±0.2V 41.6V±0.4V 41.6V±0.4V 83.2V±0.4V 104V±0.4V
status of mains availability, battery status, solar status etc. 30% More Efficient Change over me UPS mode < 10msec < 4msec
Change over me WUPS mode < 25msec
Trendy+ MPPT Solar PCU is 30% more efficient than Cooling Temp. Controlled Fan
PROTECTIONS
tradi onal PCUs, especially due to Smarten's impeccable Smart Charging even Overload in backup mode Yes provided, system will indicate on display at 101% load
solar panels. It comes with four levels of ba ery depth of During Low Voltage 90V*
Short Circuit in Backup Mode System will shutdown a er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains MCB will trip
d i s c h a r g e o p o n s f o r y o u r d i ffe r e n t p o w e r Back feed System will shutdown in case of back feed and there is no retry
requirements. 10ms changeover me, and triple Grid Charging Enable / Over temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse Battery DC fuse will blown DC MCB will trip
protec on to protect house wiring and appliance. Disable Op on for Reduced Phase to Phase protection in mains mode Yes provided by electronic
SOLAR CHARGE CONTROLLER
Electricity Bill Solar Charge Controller type MPPT
Max Panel wattage can be connected 750 WATT 1500 WATT 3000 WATT 4000 WATT 6500 WATT 8000 WATT
Maximum PV Voltage 50V 103±2V 135V 150V 250V 350V
Maximum PV current 50 Amp.
Efficiency > 93%
Reverse PV protection Yes provided, it will also display on LCD panel
Switches Menu (Select), Up, Down, Esc
Reverse current flow to PV Yes provided
Sharing of current when PV and Grid Both are available If PV power is not sufficient enough to charge the ba ery, system will start sharing ba ery charging from PV and grid.
DOD defini on (Depth of Discharge) Mains will be connect when ba ery voltage reach at defined value of the ba ery voltage.
20% - if battery voltage is 12.5V 25.0V±0.2V 50.0V±0.2V 100V±0.2V 125V±0.2V
DOD 30% - if battery voltage is 12.0V 24.0V±0.2V 48.0V±0.2V 96V±0.2V 120V±0.2V
(Depth of Discharge) 40% - if battery voltage is 11.5V 23.0V±0.2V 46.0V±0.2V 92V±0.2V 115V±0.2V
50% - if battery voltage is 11.0V 22.0V±0.2V 44.0V±0.2V 88V±0.2V 110V±0.2V
SOLAR>GRID>BATTERY SOLAR>GRID>BATTERY
Mode Selec on
SOLAR>BATTERY>GRID SOLAR>BATTERY>GRID
LED BULB TULLU PUMP JUICER MIXER PC LED TV DISPLAY AND ALARMS
Welcome, SMARTEN Website Address, System Capacity, Charging Till 90VAC and Deep Discharge Battery,
LCD Ini al Display
System Se ng, UPS / WUPS mode, I/P range 90-295VAC / 170-265VAC, Battery Type Selected LA / SMF / Tubular, DOD.
Mains ON, Input Voltage, Input Frequency, Ba ery Voltage, Ba ery Charging, Ba ery Charged, Charging Current, Backup Mode,
LCD Status Display UPS ON, UPS OFF , Battery Voltage, Load %, Output Voltage, Output Frequency, Ba ery Current, PV Current,PV Voltage.
Mains Low Cut, Mains High Cut, Mains Not Available, Mains Frequency Cut
LCD Fault / Protection Status Display Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Ba ery Low, High Temperature, Back feed
Buzzer Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Ba ery Low, High Temperature, Back feed
ENVIRONMENT
Opera ng Temperature 0°C to 50°C
Storage Temperature 0°C to 50°C
Operating Rela ve Humidity 90% Non-Condensing
WEIGHT AND DIMENSIONS
REGRIGERATOR SUBMERSIBLE PUMP DENTAL CHAIR PHOTOCOPIER Dimensions in mm (LxWxH) 425X315X335 415x320x415 518x415x515 608x485x660
Weight (Kg) 15 25 30 42 48 82.8 86.6
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 850VA 1050VA 1250VA 1500VA 2675VA 3250VA 3500VA 5500VA 5500VA 6000VA 7500VA 10000VA
MAINS INPUT MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery W.UPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery W.UPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
BATTERY
Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V 48V 96V 72V 96V 120V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2 4 8 6 8 10
Float charging voltage 13.7V±0.2V 27.4V± 0.2V 54.8V±0.4V 109.6V±0.4V 82.2V±0.4V 109.6V±0.4V 137V±0.4V
Bulk absorp on Voltage 14.8V±0.2V 59.2V±0.4V 118V±0.4V 88.8V±0.4V 118V±0.4V 148V±0.4V
Boost charging voltage for LA Ba ery 14.0V±0.2V 28.0V±0.3V 28.0V±0.2V 56.0V±0.4V 111.5V±0.5V 83.5V±0.5V 111.5V±0.5V 139.5V±0.5V
850 VA - 10 KVA Boost charging voltage for Tubular and SMF Ba ery 14.5V±0.2V 29.0V±0.2V 29.0V±0.2V 57.8V±0.4V 115.5V±0.5V 86.5V±0.5V 115.5V±0.5V 144.5V±0.5V
Ba ery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
Charging Current at Grid priority/Ba ery priority 15A ± 3A 13A ± 3A
Grid Charging Enable/Disable Op on Yes
BACKUP MODE
Output voltage 220VAC +5% -10%
Smarten’ PWM Solar PCU (Power Condi oning Unit) is an Big LCD Screen Output frequency 50Hz ± 0.2 Hz
intelligent integrated system of Solar Charger, Grid for all No fica on
Output waveform Pure Sine Wave ≤ 5% THD
No Load current <1.8A
Charger, Offline Inverter. The of the PCU is designed to Discharging current @ full load 40A ± 2A 50A ± 2A 60A ±3A 90 ±3A 70 ±2A 90 ±3A 60A ± 2A 90A ± 2A 46A ± 2A 66A ± 2A 66± 2A 66A ± 2A
run the load & charge the ba ery simultaneously while Low Ba ery Warning
Set Solar Charging Current Low Ba ery Cut
10.8±0.2V
10.4V±0.2V
21.4V ± 0.2V
21V ± 0.2V
43.2V±0.4V 43.2V±0.4V 86.4V±0.5V 64.8V±0.5V 86.4V±0.5V 108±0.5V
41.6V±0.4V 41.6V±0.4V 83.2V±0.5V 62.4V±0.5V 83.2V±0.5V 104V±0.5V
extrac ng power from Solar. as per Ba ery Capacity Change over me UPS mode < 10msec < 4msec
Change over me WUPS mode < 25msec
Smarten’s PWM PCU stand apart from the rest as the PROTECTION
Phase to Phase Voltage Protec on Mains Mode
maximum u lisa on of solar power happens through Recover Deep Discharge Back feed protec on Mains apply in output side@<295V
this. Also, this Solar PCU is user friendly basis the Ba ery Even Zero Over Load system Shutdown > 130% a er approx >180sec, and > 300% system will be shutdown approx < 20 Sec.
Short Circuit (A PK-PK) Yes, A er 3 tries system will be shutdown (System reset from front switch)
privilege of personalised se ngs through the op ons Volt Gravity Reverse Ba ery DC Fuse Burn Ba ery MCB will trip
given on the PCU itself such as connec ng or SCC Reverse Ba ery DC Fuse Burn
Short Circuit in Mains Mode Mains Fuse will blown Mains MCB Trip
disconnec ng with mains. Saver Solar PCU is highly In built 70 Amp* strong Ba ery Over Charge Yes, Provided
High PV V oltage 55V ± 2V
efficient even to run submersible pump. solar charge controller Reverse PV Connected Yes, Provided
Over Charge Protec on Yes, Provided
Over Current Protec on PV Yes, Provided
SOLAR CHARGE CONTROLLER
Solar Charge Controller type PWM type
Max Panel wa age can be connected 600W 800W 1200W 2400W 3000W 4000W 6500W 4500W 6500W 8000W
Max PV current 25A 40A 70A 70A 50A 70A 50A 50A 50A 50A
Reverse PV protec on Yes provided
Reverse current flow to PV Yes provided
Sharing of current when PV and Grid Both are available If PV power is not sufficient enough to charge the ba ery, system will start sharing ba ery charging from PV and grid.
Op on for Grid and Battery priority Yes, provided, user can set priority for Ba ery or Grid. Hence user can set system in electricity bill saving.
DOD defini on (Depth of Discharge) Mains will be connect when ba ery voltage reach at defined value of the ba ery voltage.
20% - if battery voltage is 12.5v±0.2V 25.0v±0.2V 50.0V±0.2V
DOD 30% - if battery voltage is 12.0v±0.2V 24.0v±0.2V 48.0V±0.2V
(Depth of Discharge) 40% - if battery voltage is 11.5v±0.2V 23.0v±0.2V 46.0V±0.2V
50% - if battery voltage is 11.0v±0.2V 22.0v±0.2V 44.0V±0.2V
Solar>>Battery>>Grid
Solar>>Grid>>Battery Grid>>Solar>>Battery Solar>>Grid>>Battery
Mode Selec on
LED BULB TULLU PUMP JUICER MIXER AIR CONDITIONER LED TV Solar>>Battery>>Grid
Solar>>Grid>>Battery
Solar>>Battery>>Grid
BATTERY CHARGING CURRENT BY SOLAR
30% ba ery will charged with 20Amp.± 3Amp.
40% ba ery will charged with 30Amp.± 3Amp.
50% ba ery will charged with 40Amp.± 3Amp.
100% ba ery will charged with 70Amp.± 3Amp.
LCD DISPLAY
Messages (Display Values can be different 2% from the RMS actual values)
Mains Input Voltage / Ba ery Voltage / Mains Fuse Blown / Solar Power Available or Not. / Reverse PV / High PV Voltage /
Mains Current / Solar Current / Ba ery Current / PCU ON, OFF / Ba ery Voltage / Ba ery Current / Solar Power Available or
Not / Load % . / Short Ckt. / Over Load / Wiring Fault / Ba ery Low. / Ba ery High / Out Put Voltage / High Temp. / Output Frequency.
LCD Display Mains Disconnected, Connected Selec on
REGRIGERATOR SUBMERSIBLE PUMP DENTAL CHAIR PHOTOCOPIER If solar is available ba ery reaches float voltage a er <5 min. mains will be disconnected,
when mains is connected ba ery voltage reaches permi ed DOD voltage and solar power not available.
NOTE: This Condi on is not applicable for Grid >> Solar >> Ba ery Condi on.
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 1050VA 1250VA 1500VA 2250VA 2675VA 3250VA 4000VA 5500VA 7500VA 10000VA
MAINS INPUT MODE
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery W.UPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery W.UPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
BATTERY
Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V 48V 96V 120V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2 4 8 10
Float charging voltage 13.7V±0.2V 27.4V±0.2V 54.8V±0.4V 109.6V±0.4V 137V±0.4V
www.smartenpowersystems.com www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
MODEL NAME 400VA 2050VA
Mains AC low cut UPS mode 175VAC ± 10VAC
Mains AC low cut recovery UPS mode 185VAC ± 10VAC
Mains AC high cut UPS mode 265VAC ± 10VAC
Mains AC high cut recovery UPS mode 255VAC ± 10VAC
Mains AC low cut WUPS mode 90VAC ± 10VAC
Mains AC low cut recovery WUPS mode 110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery WUPS mode 285VAC ± 10VAC
Input Frequency Range 40Hz to 60Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input
BATTERY
400 VA & 2050 VA Ba ery Type LA / Tubular / SMF
DC input voltage 12V 24V
Ba ery Quan ty 12V 100Ah to 220Ah 1 2
Float charging voltage 13.7V±0.2V 27.4V±0.2V
Smarten’ PMW Solar PCU (Power Condi oning Unit) is an Bulk absorp on Voltage 14.8V±0.2V 29.6±0.2V
affordable device with LED Display. The PCU works as good Smart Solar Op miza on Boost charging voltage for LA Battery 14.0V±0.2V 28.0V±0.3V
as other Solar PCU but pre y economical for any User Se ng Boost charging voltage for Tubular and SMF Battery 14.5V±0.2V 28.8V±0.3V
Ba ery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Ba ery)
household. It func ons to run the load & charge the
Charging Current at Grid priority/Ba ery priority 12A ± 2A 15A ± 3A
ba ery simultaneously while extrac ng power from Solar. Extremely BACKUP MODE
Smarten’s PWM PCU stands apart from the rest as the Economical Output voltage 220VAC±10%
Output frequency 50Hz ± 0.2 Hz
maximum u lisa on of solar power happens through
this. Also this Solar PCU is user friendly basis the privilege Solar Panel Capacity Output waveform Pure Sine Wave ≤ 5% THD
upto 500W to 1500W No Load current <1.5A <1.8A
of personalised se ngs through the op ons given on the Discharging current @ full load 28A ±2A 60A ± 2A
PCU itself such as connec ng or disconnec ng with Low Battery Warning 10.8±0.2V 21.6V±0.2V
mains. Saver Solar PCU is highly efficient to run consumer User Friendly Low Battery Cut 10.4V±0.2V 20.8V±0.2V
durable device as Juicer Grinder. LED Display Change over time UPS mode < 10msec
Change over time WUPS mode < 25msec
PROTECTIONS
Overload in backup mode Yes provided, system will give indica on at 101% load
Short Circuit in Backup Mode System will shutdown a er 3 - retries in case of output short circuit
Short Circuit in Mains Mode Mains Fuse will blown
Back feed System will shutdown in case of back feed and there is no retry
Over temperature Yes provided, if heat sink temperature goes above 100°C System will shut down
Reverse Ba ery DC fuse will blown
Phase to Phase protec on in mains mode Yes provided by electronic
SOLAR CHARGE CONTROLLER
Solar Charge Controller type PWM type
Max Panel wa age can be connected 600W 1500W
Max PV current 25A 50A
Reverse PV protec on Yes provided
LED BULB TULLU PUMP PC LED TV Reverse current flow to PV Yes provided
If PV power is not sufficient enough to charge the ba ery, system will start sharing
Sharing of current when PV and Grid Both are available
ba ery charging from PV and grid.
Yes, provided, user can set priority for Ba ery or Grid. Hence user can set system
Op on for Grid and Battery priority
in electricity bill saving.
ALARMS
Audible beep for Overload, Short Circuit, Back feed, Low Ba ery,
Buzzer
Over Temperature, Mains Fuse blown / MCB Trip
WEIGHT AND DIMENSIONS
Dimensions in mm (LxWxH) 301×297×160 403x392x227
REGRIGERATOR JUICER MIXER FAN CFL 15W Weight (Kg) 6.4 16.5
www.smartenpowersystems.com www.smartenpowersystems.com
TECHINICAL SPECIFICATION
MODEL: KRANTI+ 5KVA 8KVA 10KVA
Min. Solar Input Voltage 400V
Max. Solar Input Voltage 750V
Technology Digital Processor Based High Efficiency Design
Max. Load Wa age 4200 Wa * 6500 Wa * 8000 Wa *
Max.Output Current 20Amp. ± 3Amp. 30Amp. ± 3Amp. 37Amp. ± 3Amp.
Panel Install 5KW to 10KW 5KW to 20KW 5KW to 35KW
BATTERY LESS 5 KVA - 10 KVA
Output Voltage 220VAC±10%
Low Solar Cut 300V
PROTECTIONS
With the advanced technology, Smarten came up with
ba ery-less renewal energy PCU, this advanced system
Low Solar Voltage Yes Provided, It will show on display
Advanced DSP Technology
does not require ba eries for conver ng solar power High PV Voltage Yes Provided, It will show on display
into u lity power of 220V AC.
Reverse PV Protec on Yes Provided, System will not ON
It absorbs solar power directly from solar panels and if SMARTEN
WELCOMES YOU
Big LCD Display
the load driven by this system exceeds the available solar DISPLAY PARAMETERS
power, it will draw the required power from the mains to Display Type LCD Display
compensate the output power requirement without any Max Panel Voltage Range:
glitch. In conven onal solar power systems using VOC 400-700 V Display Parameters Solar PV Voltage, Load%, Output Voltage, Solar Current,
ba eries, one third of the total investment goes for Overload, Short Circuit, Low Solar Please Reduce load
ba eries and since they are required to be replaced a er No Ba ery Requirement
some years. ENVIRONMENT
0 0
Operating Temperature 0 C to 40 C
Storage Temperature 0
0 C to 50 C
0
www.smartenpowersystems.com www.smartenpowersystems.com
SINGLE PHASE ONLINE UPS
TECHNICAL SPECIFICATIONS
Parameters Units Ra ng
Model SMARTEN 3KVA 5KVA 7.5KVA 10KVA
Opera ng DC Voltage Volts 96 180 180 180
PFC PARAMETERS
Mains Input Range (Min - Max) Volts 165-265 +/- 2%
PFC BASED MAINS CHARGER
Switching Element IGBT MODULE
Controller Type DSP
Type of Charger Efficiency PFC
Ba ery Charging Stages 95%
Power Factor 5 Stages (So Start, Boost, Absorp on, Float and Equalize) 0.8 pf
BATTERY
SINGLE PHASE ONLINE UPS 3 PHASE ONLINE UPS 3 PHASE ONLINE MPPT SOLAR PCU Low Cut Off Volts 10.5 / Ba ery +/-2%
3KVA - 10KVA 5KVA - 120KVA 6KVA - 150KVA Low Cut Off Recovery Volts 11.5 / Ba ery +/-2%
Low Buzzer Volts 10.7 / Ba ery +/-2%
High Cut Off Volts 15.5 / Ba ery +/-2%
High Cut Off Recovery Volts 15.0 / Ba ery +/-2%
Boost Charging Volt by Grid(TUB) Volts 14.0 / Ba ery +/-2%
Boost Charging Volt by Grid(SMF) Volts 13.75 / Ba ery +/-2%
Charging Current by Grid Amps [2.5 (Normal) / 5 (High) +/- 2% (Default)] or [5 (Normal) / 10 (High) +/- 2% (Op onal)]
OUTPUT
Output @ No load Volts 230 +/- 2%
Output Frequency Hz 50 +/- 2%
CONFIGURABLE GALVANIC HIGH & LOW PFC CHARGER ADVANCED INDUSTRIAL MODBUS Amps 10.5 17.4 26.1 34.8
Overload
USER SETTINGS ISOLATION CHARGING DSP TECHNOLOGY MEGATECH COMM Wa s 2.4KW 4KW 6KW 8KW
Output Low Retry Output - 1 me
Short Circuit No Load - 1 me
Ba ery Current % 2%
DISPLAY
Display Alphanumeric 20X4 LCD
Output (Inverter) Voltage, Current, Power and Frequency
Input (Grid) Voltage and Frequency
Parameters
Ba ery Voltage, Current
20X4 LCD DISPLAY IGBT DESIGN 3 PHASE STAR / TRUE MPPT REMOTE AI CHARGE SHARING Status/Faults Inverter Status, Mains Status, Charger Status and Ba ery Status/Charging Stages
DELTA MONITORING IoT MAINS
No of Phase - 1Phase-3Wire P,N,E
Voltage range Frequency Volts 165-280 +/- 2%45-55
range Ba ery Charging Hz +/- 2%
Stages - 5
INVERTER
Switching Element - MOSFET
Output voltage Volts 230
• Big display for data • High & low charging op on Phase - 1Phase-3Wire P,N,E
Output Waveform - Digitally Filtered Pure Sine Wave
• Built-in energy meter • Be er output regula on Frequency Hz 50
Output Power Factor 0.8
• RS-232 (Industrial standard MODBUS or Megatec) • Cold start through mains supported Pf
Mains Bypass in case of Fault Sta c By Pass (Op onal)
• Incorporated with microchip and ST DSP engines • Maximized solar usage through Overload Retry - 3
Switch - System ON/OFF, HIGH/LOW Charging Selec on,SMF/TUB Ba ery Selec on
• Safety and protec ons intelligent modes
Indica on - UPS On, Mains In Range, Ba ery Low/High, Charger On, Overload, Faults
• 30% more power saving (power factor correc on) • 40% less panel required than other PCUs Alarm - Ba ery Low, Overload, Charger On, UPS ON
- Overload, Short Circuit Protec on, Over Voltage, Mains Surge and Transient protec on (MOV Varistors),
Protec on
• IGBT based design and fas ng charging • Wide range MPPT input Reverse Polarity of Ba ery, Over temperature Protec on, under voltage and over voltage Protec on
Cooling - Forced Air cooling(Temp Controlled)
• 6 stage ba ery charging • Works as standalone solar inverter in Communica on - Remote Monitoring System (Over GPRS / BLE and Wifi) or RS232 (Megatec)
case of no grid Opera ng Temp C 0-50
• Mul ple ba ery selec on Opera ng Humidity % 95
Protec on Class - IP20
• Sleek & Aesthe c design Dimension(LXWXH) mm 510x460x305 750x500x350 750x500x350 750x500x350
Weight KG 20 30 40 50
Note: Technical Specs are subject to change with prior no ce, because of con nous development and improvement in design and technology.
www.smartenpowersystems.com www.smartenpowersystems.com
3 IN 3 OUT - ONLINE SOLAR PCU WITH MPPT CHARGE CONTROLLER
3 PHASE ONLINE UPS
TECHNICAL SPECIFICATIONS
T ECHNICAL SPECIFICATIONS Parameters Units Ra ng
Model SMARTEN 6KVA 7.5KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA 100KVA 120KVA 150KVA
Parameters Units Ra ng
Opera ng DC Voltage Volts 240V 240V/360V 240V/360V 240V/360V 240V/360V 360V/384V 420V/480V 420V/480V 420V/480V 420V/492V 420V/492V 420V/492V 420V/492V
Model SMARTEN 5KVA 7.5KVA 10KVA 15KVA 20KVA 25KVA 30KVA 40KVA 50KVA 60KVA 80KVA 100KVA 120KVA
SPV PARAMETERS
Operating DC Voltage Volts 240V 240V 240V 240V/360V 240V/360V 240V/360V 360V 360V 360V 384V 420V 420V 420V
Max SPV Power KW 5KW 7.5KW 10KW 15KW 20KW 30KW 40KW 50KW 60KW 80KW 100KW 120KW 150KW
BATTERY
Voc range V 360-600 360-600 360-600 360-600 360-600 540-750 630-750 630-750 630-750 720-750 720-750 720-750 720-750
Low Cut Off Volts 10.5 / Battery +/-2%
V 540-750 540-750 540-750 540-750 576-750 720-750 720-750 720-750 738-750 738-750 738-750 738-750
Low Cut Off Recovery Volts 11.5 / Battery +/-2%
Compa ble SPV Panels 36 / 60 / 72 Cell
Low Buzzer Volts 10.7 / Battery +/-2%
MPPT BASED CHARGE CONTROLLER
High Cut Off Volts 15.5 / Battery +/-2%
Switching Element IGBT Module
High Cut Off Recovery Volts 15.0 / Battery +/-2%
Controller DSP
Boost Charging Volt by SPV(TUB) Volts 14.5 / Battery +/-2%
Efficiency > 95%
Boost Charging Volt by Grid(TUB) Volts 14.0 / Battery +/-2%
Max Charging Current from Solar 60 Amps
Charging Current by Grid Amps 10A +/-2%
Ba ery Charging Stages 5 (So start, Boost, Absorb on, Float, Equalise)
No Load Ba ery Current % 0.02
OUTPUT BATTERY
Output@ No load Volts 415 V AC +/- 2% Low Cut Off Volts 10.5 / Ba ery +/-2%
Output Frequency Hz 50 +/-2% Low Cut Off Recovery Volts 11.5 / Ba ery +/-2%
Overload Capacity 100% - 120% : 60 Seconds with 3 Times Auto Reset Low Buzzer Volts 10.7 / Ba ery +/-2%
Output Low Retry - 1 Time High Cut Off Volts 15.5 / Ba ery +/-2%
Output Short Circuit - 1 Time High Cut Off Recovery Volts 15.0 / Ba ery +/-2%
GRID Boost Charging Volt by SPV(TUB) Volts 14.5 / Ba ery +/-2%
No of Phase - 380V-480V 3 PHASE 4 WIRE(R,Y,B,N) Boost Charging Volt by Grid(TUB) Volts 14.0 / Ba ery +/-2%
Frequency Range Hz 45-55 Hz+/-10% Charging Current by Grid Amps 10A +/-2%
Power Factor - 0.95 No Load Ba ery Current % 0.02
Charger Topology - Buck/ Buck-Boost OUTPUT
DISPLAY Output@ No load Volts 415 V AC +/- 2%
Display Alphanumer 20X4 LCD Output Frequency Hz 50 +/-2%
Output Voltage (R,Y.B) , Current (R,Y.B), Power (R,Y.B) and Frequency (R,Y.B) Overload Capacity 100% - 120% : 60 Seconds with 3 Times Auto Reset, 120%-150% : 5 Second,<150%:1 Second
Parameters Input (Grid) Voltage(R,Y.B) and Frequency(R,Y.B) Output Low Retry - 1 Time
Battery Voltage, Current, Level (Bar Graph) Output Short Circuit - 1 Time
Status/Fault Inverter Status, Mains Status, Charger Status, Solar Status and Battery Status/Charging Stages GRID
INVERTER No of Phase - 380V-480V 3 PHASE 4 WIRE(R,Y,B,N)
Switching Element - IGBT Module Frequency Range Hz 45-55 Hz+/-10%
Output Waveform - Digitally Filtered Pure Sine Wave -
Power Factor 0.95
Changeover (Mains to Inverter) ms 0 ms Charger Topology - Buck/ Buck-Boost
Output Power Factor pf 0.8 DISPLAY
Overload Retry - 3 Times Display Alphanumeric 20X4 LCD
Indication (LED) - Inverter On, Mains In Range, Ba ery Low/High, Charger On, Overload, Faults Output Voltage (R,Y.B) , Current (R,Y.B), Power (R,Y.B) and Frequency (R,Y.B)
(Inverter)
Alarm (Audible) Ba ery Low, Overload, Charger On, Inverter On Input (Grid) Voltage(R,Y.B) and Frequency(R,Y.B)
Overload, Short Circuit Protection, Over Voltage, Reverse Polarity of Ba ery, Over temperature Protec on,
Protection - Solar Voltage, Current, Power and Energy (Op onal)
Under Voltage and Over Voltage Protec on Parameters
Battery Voltage, Current, Level (Bar Graph)
Cooling - Forced Air cooling(Temp Controlled)
Status/Faults Inverter Status, Mains Status, Charger Status, Solar Status and Ba ery Status/Charging Stages
Operating T emp C 0-50
INVERTER
Operating Humidity % 95
Switching Element - IGBT Module
Protection class - IP20
Output Waveform - Digitally Filtered Pure Sine Wave
Note: Technical Specs are subject to change with prior no ce, because of con nous development and improvement in design and technology. ms
Changeover (Mains to Inverter) 0 ms
Output Power Factor pf 0.8
Overload Retry - 3 Times
Indica on (LED) - Inverter On, Mains In Range, Ba ery Low/High, Charger On, Overload, Faults
Alarm (Audible) Ba ery Low, Overload, Charger On, Inverter On, Solar Charger On
Protec on - Overload, Short Circuit Protec on, Over Voltage, SPV Surge and Transient protec on (MOV Varistors), Reverse Polarity of Ba ery,
Over temperature Protec on, Under Voltage and Over Voltage Protec on
Cooling - Forced Air cooling(Temp Controlled)
Opera ng Temp C 0-50
Opera ng Humidity % 95
Protec on class - IP20
www.smartenpowersystems.com www.smartenpowersystems.com
TECHNICAL SPECIFICATION
MPPT 12-24 automa c MPPT 24-48 automa c
MODEL 12V 24V 24V 48V 72V 96V 120V 180V
ELECTRICAL
Ba ery Type LA/Tubular/SMF
Technology Digital Processor Based High Efficiency Design
Max. BATTERY Current Ra ng 50AMP.
Max. PV Voltage Ra ng 50V±0.5V 85V±1V 100 V±1V 135V±2V 200V±0.5V 250V±1V 350V±1V 460V±1V
High PV Voltage >50V >85V >100V >135V >200V >250V >350V >460V
Max. Panel Install up to 750W up to 1500W up to 1500W up to 3000W up to 5000W up to 6500W up to 8000W up to 12000W
Ba ery Qty.12V 100-220AH 1 2 2 4 6 8 10 15
Boost Charging Voltage For Tubular And SMF Ba ery 14.5V±0.2V 29V±0.2V 29V±0.2V 58V±0.2V 87V±1V 116V±1V 145V±1V 217.5V±1V
Boost Charging Voltage For LA Ba ery 14V±0.2V 28V±0.2V 28V±0.2V 56V±0.2V 84V±1V 112V±1V 140V±1V 210V±1V
Bulk/ Absorp on Voltage 14.8V±0.2V 29.6V±0.2V 29.6V±0.2V 59.2V±0.2V 88.8V±1V 118.4V±1V 148V±1V 222V±1V
20% - if battery voltage is 12.5V 25.0V 50.0v±0.2V
DOD level 30% - if battery voltage is 12.0V 24.0V 48.0v±0.2V
(Depth of Discharge) DOD func on is not available in this segment
40% - if battery voltage is 11.5V 23.0V 46.0v±0.2V
50% - if battery voltage is 11.0V 22.0V 44.0v±0.2V
Mains Connect if Solar Power Not Available At any Stage of Ba ery Voltage
Mains Disconnect If ba ery reaches boost level then a er <10 minutes Mains Connect disconnect
func on is not available
mains will be disconnect
12V-24V/50Amp D.O.D (Depth of Discharge) Mains will be connect when ba ery voltage reach at
defined value of the ba ery voltage
24V-48V/50Amp MPPT BASED SOLAR MPPT To PV Power Connec on Time <15 Sec.
CHARGE CONTROLLER Peak Efficiency >94%
72V-180V/50Amp Mains AC low cut WUPS mode
Mains AC low cut recovery WUPS mode
90VAC ± 10VAC
110VAC ± 10VAC
Mains AC high cut WUPS mode 295VAC ± 10VAC
Mains AC high cut recovery WUPS mode 285VAC ± 10VAC
A device to convert your simple Inverter into Solar
Input Frequency Range 40Hz to 60Hz
Inverter using advance MPPT technology. The device 30% more efficient Voltage Output in Mains Mode Same as input
comes with wall moun ng op on & can connect 24V Frequency Output in Mains Mode Same as input
panel on single ba ery. This comes with user friendly LCD Panel configura on (NTC) 375W 2P
250W 2S 250W 2S 250W 3S
330W 4S 4P 330W 5S 4P 330W 6S 4P 330W 10S 4P
DOD, can set four ba ery 3P/300W 5P 3P/300W 5P 4P/ 330W 3S 3P
that displays important informa on like ba ery charging
discharge levels. Panel configura on VOC (NTC) 39.75V 74V/ 44V 74V/ 44V 111V/132V 180V 225V 270V 450V
status, charging source, total units savings etc. Also has PROTECTIONS
(20%, 30%, 40%, 50%)
world class MCB ensures your UPS and connected loads Reverse Ba ery Yes
Reverse PV Protec on Yes
stay protected from short circuits. Other advantages are Grid control for saving Reverse Current Flow to PV Yes
in terms of complete protec on, reverse PV, ba ery the electricity bill High PV Voltage Yes
deep discharge, ba ery over charging and high temp. Over Current Yes
Thermal Protec on Yes
Smart auto detect ba ery MCB MCB ensures your UPS and connected loads stay protected from short circuits
www.smartenpowersystems.com www.smartenpowersystems.com
TECHNICAL SPECIFICATION
MODEL: 12V/20A DC MPPT SOLAR PCU
Battery Volt 12V
Battery Type Lead Acid / Tubular
Technology Digital Processor Based High Efficiency Design
Max. Battery charging Current 20 Amp.
Charge controller Ra ng 20 Amp.
Max. Solar VOC 50V
Min. Solar VOC 20V
PV High Cut >50V
PV High Cut Recovery 45V
Max. Panel Install 260W
Low Battery Cut 10.6V
Ba ery Boost Voltage LA Mode 14.0V
Battery Boost Voltage Tub Mode 14.5V
Battery Float Voltage 13.7V
Battery High cut 15V
DC load Ra ng 15 Amp.
Mobile Chraging 500 mAMP.
DC MPPT SOLAR PCU DC load ON/OFF BY Power Switch
MPPT To PV Power Connection Time 15 Sec.
DC load Solar Charge Controller 12V-20A Peak Efficiency >94%
SCC Type MPPT
PROTECTIONS
Battery Low Yes Provided, It Will show on display
The device comes with wall moun ng op on & can High PV voltage Yes Provided, It Will show on display
connect 24V panel on single ba ery. The product has 100% shock proof Reverse PV Protection Yes Provided,it will also show on display
digital Processor based high efficiency design also give Reverse Current Flow to PV Yes Provided
op on to charge mobile phone. A user friendly LCD that Reverse Ba ery Protec on Yes provided,System is not ON in Reverse Ba ery
displays important informa on like ba ery Charging MPPT Technology load short circuit protec ons Yes, provided, it will show on display
Status, Charging Source, etc. Other advantages are in (Upto 20% more power saving) If DC load connect more then 15 Amp. System show on display,a er 3 retries load will be
Load overload Protec on
terms of Complete Protec on, Reverse PV, Ba ery Deep shutdown
Discharge, ba ery over charging and High Temp. DISPLAY PARAMETERS
Inbuilt USB mobile charger Display Type LCD Display
Reverse PV/High PV voltage /High Temp./DC Load overload,DC load short circuit,Ba ery
*
Display Parameters voltage,Battery Current,PV voltage,PV current,Low Ba ery,DC load Voltage, DC load
Upto 24hrs back-up Current,Solar power available/Not Available
SAFETY
HV T est Input to Earth
Leakeage current <5MAmp.when 1.5KV Applied for 1 Min.
HV T est Output to Earth
IR T est Input to Earth
<5MΩ between @500V DC
IR T est Output to Earth
ENVIRONMENT
Operating Temperature 0℃ To 40℃
Storage Temperature 0℃ To50℃
Operating Rela ve Humidity 90% Non-Condensing
WEIGHT AND DIMENSIONS
Dimensions in mm (LxWxH) 310x310x180
Weight (Kg) 3.2
www.smartenpowersystems.com www.smartenpowersystems.com
PWM BASED SOLAR 12V/120V-50A PV CHANGER
CHARGE CONTROLLER
A device to convert your simple Inverter into Solar DOD, can set four ba ery discharge levels.
Inverter using PWM Technology. The device comes with (20%, 30%, 40%, 50%)
wall moun ng op on with user friendly LCD that displays
important informa on like ba ery Charging Status, Grid control for saving the electricity bill
Charging Source, Total units savings etc. Also has world
class MCB ensures your UPS and connected loads stay Smart auto detect ba ery func on
protected from short circuits. Other advantages are in YOU CAN USE THE PANEL MOUNTED ON THE SOLAR PUMP BY
terms of Complete Protec on, Reverse PV, Ba ery Deep KRANTI PV CHANGER IN YOUR HOME AS PER YOUR REQUIREMENT
Convert normal inverter to solar inverter
Discharge, ba ery over charging and High Temp.
www.smartenpowersystems.com www.smartenpowersystems.com
LITHIUM BATTERY
LITHIUM
P WER
BLUETOOTH EXTRA LOW SELF
CONNECTIVITY MILE DISCHARGE
SMARTEN SMARTEN
TECHNICAL SPECIFICATION LI-ION BATTERY (LFP)
12.8V-105Ah 25.6V-105Ah
SOLAR TALL
SMARTEN 170 Ah - 350 Ah
TUBULAR BATTERY
Low self
Long life
discharge
www.smartenpowersystems.com www.smartenpowersystems.com
www.smartenpowersystems.com
TALL TUBULAR
170 Ah - 200 Ah
BATTERY
Sl. No. Model Volts Capacity Ini al Charging Dimensions Sl. No. Model Volts Capacity Initial Charging Dimensions
@C20 Current (Amps) (HxWxL) mm @C20 Current (Amps) (HxWxL) mm
1. BRTT 1700 12 170 Ah 15A 525 x 280 x 320 1. NVTT 1800 12 180 Ah 15A 503 x 193 x 412
2. BRTT 2000 12 200 Ah 15A 503 x 193 x 412 2. NVTT 2000 12 200 Ah 15A 503 x 193 x 412
www.smartenpowersystems.com www.smartenpowersystems.com
SOLAR TALL
170 Ah
TUBULAR BATTERY
Forever Glow with Shine! High Durability cells with sealed plas c body, the tall tubular ba ery is best suited for home & commercial
With a range of inverter batteries to suit varying needs and applications of end users, Smarten inverter purpose. Efficient ba ery with higher Ah efficiency comes with low maintenance with level indicators. The
batteries are compatible with any brand of inverters available in the market, so you are never at a loss for tall tubular ba eries are manufactured with robust tubular plate technology to ensure long las ng
power. When you buy a Smarten inverter battery, you enjoy a completely hassle-free experience as the performance, durability & strength.
battery uses a high heat resistant modified hybrid alloy for its grids which makes it zero-maintenance.
They are also designed to withstand long and frequent power cuts Smarten also offers a range of
technologically advanced inverters and home ups system for complete peace of mind.
www.smartenpowersystems.com www.smartenpowersystems.com
TUBULAR &
40 Ah & 180 Ah
TALL TUBULAR BATTERY
Worry not, lets boom! With the highest quality materials and based on the in cloudy weather, and don't even get damaged in
No worry for long power cuts! Boom tubular inverter ba ery for home offers complete sa sfac on during latest solar technology, Smarten Solar Panels are winds of 120 km/hr.
power cuts. These inverter ba eries are leak proof tower type polypropylene container with rela vely completely immune to India's extreme heat, cold, dust Smarten Solar Panels help you cut down your
more electrolytes. Tubular plates are custom designed for uninterrupted power delivery during long and heavy rainfall. Whatever the weather, these panels electricity bills and also friendly to the environment.
power cuts. They are 100% safe to use & reliable for every home. are cared to serve you reliably for 25 years or more. We urge you to invest in this very best of investments,
Authen c, durable, with the highest efficiency of solar both for yourself and your planet.
cells, Smarten Solar Panels offer the best performance
*
Conditions apply
www.smartenpowersystems.com www.smartenpowersystems.com
EV SCOOTER CHARGER
SOLAR DC WIRE SOLAR DC WIRE, 4 Sq. mm, HRFR-105 UV GRADE
60V / 4A
SOLAR DC WIRE, 4 Sq. mm, HRFR-105 UV GRADE
4 Sq. mm, HRFR-105 UV GRADE
FEATURES
• Heavy duty wire • UV, ozone, temperature & 5 Stage FLC Charging Technology
• Designed for solar application hydrolysis resistant
0
• Compatible from -20 C to 105 C
0
• Excellent encapsulation Compa ble for Lithium Ion & Lead Acid
• Electron beam cross linked compound • Very long/service life >25 years
• Fire retardant, low smoke
Reliable Charging
Available in:
Compact Size Charger
Single Core & 2 Core | 80 mtr. & 100 mtr.
www.smartenpowersystems.com www.smartenpowersystems.com
RETRO-FIT KIT
For the Greener Tomorrow Create a Pollution Free, Green World with Smarten E-CYC’KAL
BLDC Mileage: Speed Lithium-ion Shimano Speed Mileage 1 year Carrying capacity
Motor 30-35 Km /charge 25 Km/hour battery Gears 25 Km/hr 50km/charge warranty upto 80 Kg
www.smartenpowersystems.com www.smartenpowersystems.com