You are on page 1/ 52

INDEX

List of Hybrid
Hydraulic Unit P.3 to 4
Models
INVERTER HYDRAULIC UNIT List of Super Unit
Models P.5
Nomenclature

Main Features and


Functions P.6
Excluded from high-efficiency motor regulations Super Unit Hydraulic Circuits

Features P.7 to 8

Functions P.9

Function Option P.10

Hardware Option P.11 to 12

Pressure – Flow
Rate Characteristics P.13 to 14
(Typical)

Specifications/External
Dimension Diagram P.15 to 24
7 MPa
Specifications/External
Dimension Diagram P.25 to 28
10 MPa
Specifications/External
Dimension Diagram P.29 to 32
16 MPa
Specifications/External
Dimension Diagram P.33 to 38
21 MPa

Operation Panel P.39 to 40

Electric Wiring P.41 to 43

Options
P44. to 48
(Separately available parts)

Method of Selection P.49

Handling P.50

Oil Hydraulic Division


Oil Hydraulic Equipment
Get more than energy savings!!
Saving energy is essential.
However, the Daikin hydraulic system goes
one step further than conventional models.
Daikin practices environmentally friendly production by promoting energy savings in the
production field and by reducing waste through recycling.
In the pursuit of higher usability and more diversified functions, Daikin combined its original
high-efficiency IPM motors and pump switching control technology. The Super Unit
incorporates the multi-stage pressure/flow rate control system as well as the functions of
conventional hydraulic units, resulting in the use of fewer valves.
Daikin intends to promote energy savings through advanced hydraulic systems with the aim
of contributing to improvement of factory environments, and to continuously introduce
hydraulic systems that lead the industry.

01
Combining Daikin’s original high-efficiency IPM motors
and hydraulic technology enables an Movie of IPM
unparalleled energy-saving effect and motor for easy
understanding
advanced functions. URL https://www.daikinpmc.com/en/mv/ipm_motor.html

Energy-saving technology that supports hybrid products


♦ Daikin was the first in the industry to introduce an “Double torque” improves the energy-saving effect.
interior permanent magnet synchronous motor (IPM
motor) into air conditioners for household use. Combining two rotational forces, “magnetic torque” generated by a
Daikin was also an early adopter in the industry of powerful neodymium magnet1 and “reluctance torque”2, generates
the IPM motor for use in industrial-use air more power with less electricity.
conditioners. We have led the industry as a front Neodymium
runner in air conditioner energy-saving performance. Ferrite magnet magnet
♦ Hybrid products equipped with variable speed
motors, developed by making full use of Daikin’s Neodymium magnets
original energy-saving motor technology and provide more power –
its production capacity, help to achieve substantially more
energy savings for factory equipment Powerful than the ferrite
magnets in general
neodymium use.
magnets, the key to
this improved
energy-saving
effect! 1: A compound of neodymium (Nd, rare-earth element), iron (Fe), and boron (B).
Neodymium magnets are known to have superior magnetic properties.
2: Rotational force generated by attractive force (reluctance = magnetic resistance)
between iron and a magnet.

Fundamental Principle of the IPM Motor


With a rare-earth permanent magnet deeply embedded in the rotor, the IPM motor uses an electromagnetic structure
that maximizes magnetic torque (attractive/repulsive force between the coil and permanent magnet) and reluctance
torque (force of the coil that attracts iron).
This structure achieves high torque and maximum efficiency while suppressing heat generation.

Structure of the IPM motor Structure of a conventional motor (AC servomotor)


Stator Iron Stator Magnet
Rare-earth Rotating
magnet IPM motor drive system magnetic field SPM motor
S (Interior permanent magnet N S (Surface permanent magnet
N N synchronous motor) synchronous motor: e.g.,
S
S N servomotor, brushless DC
Rotor Rotor motor)
Since the magnetic field lines at
the south pole side are made
S longer than those at the north pole S The lengths of the magnetic
side, the magnetic field lines at field lines at the south and north
the south pole will try to shorten poles are equivalent. Therefore,
like a stretched rubber band no reluctance torque that
N
contracts, resulting in rotational N results in rotational force is
force due to reluctance torque in generated.
the direction indicated by arrow.

[1] Comparison of motor efficiency [2] Large torque at low speed

100 Daikin IPM motor 140 Daikin IPM motor

95 • Daikin IPM motors 120 • Daikin IPM motors


have even greater are capable of
Motor efficiency (%)

90 efficiency than 100 outputting a large


Torque (%)

general-purpose torque in low-speed


85 High-efficiency 80
induction motors and ranges, eliminating
induction motor
high-efficiency the problems with
80 60 General-purpose
induction motors. insufficient torque in
induction motor
low-speed ranges
75 40 often observed with
General-purpose
induction motor general-purpose
70 20 inverters.
65 0
0 1 2 3 4 5 6 0 1000 2000 3000 4000

Rated output (kW) Rotation speed (min−1)

02
Specifications vary depending on the machine
The Daikin product lineup provides various

For machine tools


Maximum
discharge EcoRich EcoRich R Super Unit (high-performance type)
rate

110 SUT00S11007 16
L/min PQ

Equivalent to Hyb.
11.0 kW Win
See Pages 23 to 24

80 SUT00S8007 16 Hyb.
L/min PQ Win

SUT10S8007

Equivalent to
7.0 kW
See Pages 21 to 22

60 SUT00S6007 16 Hyb.
PQ Win
L/min

SUT06S6007

Equivalent to
5.0 kW
See Pages 19 to 20

40 SUT00S4007 16 Hyb.
PQ Win
L/min

SUT03S4007

Equivalent to
3.7 kW
See Pages 17 to 18

30 SUT00S3007 16 Hyb. SUT00S3010 16 Hyb.


L/min Win
PQ PQ Win
EHU3007 EHU30R-M07
28.5
L/min
Equivalent Hyb. SUT03S3007 SUT03S3010
to2.8 kW Win

25 EHU2504 EHU2507
16 Equivalent
Equivalent Equivalent Equivalent to Equivalent to
L/min PQ to 2.8 kW
to 1.5 kW to 2.2 kW 2.8 kW 3.7 kW
Hyb.
Hyb.
Win
Win See Pages 15 to 16 See Pages 27 to 28

15 EHU1404 EHU15R-M07 SUT00S1507 16 Hyb. SUT00S1510 16 Hyb.


Equivalent PQ Win PQ Win
L/min
to 0.75 kW
SUT03S1507 SUT03S1510

16 Equivalent
Equivalent to Equivalent to
PQ to 2.2 kW
2.2 kW 2.8 kW
Hyb. Hyb. Hyb.
Win Win Win See Pages 15 to 16 See Pages 25 to 26

Maximum
operating
pressure
4 MPa 7 MPa 7 MPa 7 MPa 10 MPa
16-pattern Communication Analog command Hyb. Hybrid-Win compatible
PQ control function input
Win * Refer to Page 9.

03
type.
functions and capacities according to the machine type.

For general industrial machines


Maximum Super Unit
Super Unit (high-performance type) discharge
rate (high-precision type)

300 SUT00D30028
SUT00D11021 16

List of Hybrid Hydraulic Unit Models


Hyb.
L/min Hyb.
PQ Win Win
Equivalent to
P-SUT20D11KW 37.0 kW

Equivalent to
11.0 kW SUT00D22028
220 Hyb.
See Pages 37 to 38 L/min Win

Equivalent to
SUT00D8021 16 Hyb. 37.0 kW
PQ Win

SUT10D8021
SUT16D8021
SUT00S20018 SUT00D20021 S-SUT00D20025
200 Hyb. S-SUT00D20021 Hyb.
Equivalent to L/min Win Win
Hyb.
7.0 kW Equivalent to Win Equivalent to
See Pages 35 to 36 22.0 kW Equivalent to 22.0 kW
15.0 kW
SUT00D6021 16 Hyb.
PQ Win

150 SUT00S15018 SUT00D15021


SUT06D6021 L/min Hyb. Hyb.
Win Win
SUT10D6021
Equivalent to Equivalent to

Equivalent to
15.0 kW 15.0 kW
5.0 kW
See Pages 33 to 34

SUT00D4016 16 Hyb. 130 SUT00S13018 SUT00S13021 S-SUT00D13025


SUT00D13021
PQ Win L/min Hyb. Hyb.
Win Hyb. Win
Equivalent to Win Equivalent to
SUT06D4016 15.0 kW Equivalent to 15.0 kW
15.0 kW

Equivalent to
3.7 kW
See Pages 31 to 32
80 SUT00S8018 SUT00D8021 S-SUT00D8025
L/min Hyb. Hyb. Hyb.
Win Win Win
Equivalent to Equivalent to Equivalent to
SUT00S3016 16 Hyb. 11.0 kW 11.0 kW 11.0 kW
PQ Win

SUT06S3016

50 SUT00S5021 SUT00S5025
Hyb.
Hyb.
Equivalent to L/min Win Win

5.0 kW Equivalent to Equivalent to


See Pages 29 to 30 11.0 kW 15.0 kW

SUT00S1516 16 Hyb.
PQ Win

30 SUT00S3018 SUT00D3021
SUT03S1516 L/min
Hyb. Hyb.
Win Win

Equivalent to Equivalent to
7.0 kW 7.0 kW
Equivalent to
3.7 kW
See Pages 29 to 30

Maximum
16 MPa 21 MPa operating
pressure
18 MPa 21 MPa 25 MPa 28 MPa
*1: The above motor capacities are given for guidance only and do not represent the standard capacities of general motors.
*2: When selecting a Super Unit, verify the specifications of each model by referring to “Pressure – Flow rate Characteristics (Typical)” on Pages 13 and 14 and “How to Select a Super Unit” on Page 49.
For the purpose of making improvements, the specifications given in this catalog are subject to change without prior notice. Be sure to see the latest model chart.

04
List of Super Unit models

 Selecting the optimum model from a wide variety of Super Unit models
Maximum Maximum flow rate Tank
operating Maximum
Series Motor capacity flow rate (L/min) Motor pump type Unit type capacity Page
Equivalent to 2.2 kW pressure
(MPa) (L/min) 10 20 30 40 50 60 70 80 90 100 110 (L)

2.2 7.0 15.2 SUT00S1507-30 SUT03S1507-30 30


15 to 16
2.8 7.0 28.5 SUT00S3007-30 SUT03S3007-30 30

3.7 7.0 39.7 SUT00S4007-30 SUT03S4007-30 30 17 to 18

5.0 7.0 61.1 SUT00S6007-30 SUT06S6007-30 60 19 to 20


Single 7.0 7.0 83.0 SUT00S8007-30 SUT10S8007-30 100 21 to 22
pump
type 11.0 7.0 110.0 SUT00S11007-40 23 to 24

2.8 10.0 15.2 SUT00S1510-30 SUT03S1510-30 30 25 to 26

3.7 10.0 25.6 SUT00S3010-30 SUT03S3010-30 30 27 to 28

3.7 16.0 15.2 SUT00S1516-30 SUT03S1516-30 30


29 to 30
5.0 16.0 25.6 SUT00S3016-30 SUT06S3016-30 60

7.0 Combination 41.0


3.7 SUT00D4016-30 SUT06D4016-30 60 31 to 32
15.7 Independent 16.0

7.0 Combination 61.1 SUT06D6021-30 60


5.0 SUT00D6021-30 33 to 34
Double 20.6 Independent 21.2 SUT10D6021-30 100
pump
type 7.0 Combination 83.0 SUT10D8021-30 100
7.0 SUT00D8021-30 35 to 36
20.6 Independent 28.7 SUT16D8021-30 160

7.0 Combination 110


11.0 SUT00D11021-40 P-SUT20D11KW-40 200 37 to 38
20.6 Independent 40.5

Nomenclature

 Equivalent to 2.2 to 7.0 kW


SUT 03 S 15 07 30   
a b c d e f g h i

a Model No. d Pump discharge rate f Design No. h Hardware Option i Non-standard No.
 SUT : SUT series  15: 15 L/min  Incremented at Unit cover (SUT06S3016 and  N: Without control system
 30: 25 L/min model changes 01  A: With control system
30 L tank excluded)
b Tank capacity  40: 40 L/min 30, ....
02 Controller cover (except for 7 kW)
 00: Motor pump type  60: 60 L/min 03 DCL (except for 7 kW)
g Function Option
 03: 30 L  80: 80 L/min Separate power supplies for
 C: With communication function 04 power system and control system
 06: 60 L
 10: 100 L
e Maximum operating (RS232C)
05 Water fill test compliant tank
 16: 160 L pressure  P : With analog input function
06 Water leak test compliant tank
 07: 7.0 MPa 07 Level switch
c Pump type  10: 10.0 MPa 08 Temperature switch
 16: 15.7, 16.0 MPa 09 Thermometer
 D: Double pump type
 21: 20.6 MPa 10 Micro separator
 S : Single pump type
11
Combination of 1 to 10 above
...

 Equivalent to 11 kW
SUT 00 S 110 07 40  
a b c d e f g h

a Model No. d Pump discharge rate f Design No. h Non-standard No.


 SUT: SUT series ● 110: 110 L/min ● Incremented at  N: Without control system
model changes  A: With control system
b Tank capacity e Maximum operating 30, ....
 00: Motor pump type pressure g Function Option
 07: 7.0 MPa
 C: With communication function (RS232C)
c Pump type  21: 20.6 MPa
Protocol:
 D: Double pump type Daikin original protocol (conventional)/
 S: Single pump type Modbus-RTU (to be supported soon)
 P: With analog input function

05
Main features and functions

1 Energy-saving
3 Excluded from high-efficiency motor regulations
Features

Daikin’s original energy-saving motor technology The Super Units that incorporate a
utilizing high-efficiency IPM motors provides an high-efficiency IPM motor are excluded from
energy-saving ratio of 50%. high-efficiency motor regulations.
 The motor rotation speed control controls the flow rate and pressure of
the fixed displacement pump.
 The highly-efficient motor adopted in this unit achieves energy savings
even in applications for general industrial machinery where actuators
4 Restricted oil temperature rise
Motor speed control also leads to restriction of the oil
have high duty ratios. temperature rise.
 The single pump type is a highly-functional series to make it more useful.
 The double pump type uses the autonomously-switching,  The restricted oil temperature rise inhibits deterioration of the

Main Features and Functions


List of Super Unit Models, Nomenclature,
fixed-displacement double pump system, which combines large- and hydraulic oil.
small-capacity pumps in the low pressure, high flow rate range, and  This also lowers the heat load for air conditioning equipment
autonomously switches to the single operation of the high-pressure,
small capacity pump in the high pressure, low flow rate range. In this
way, the double pump type ensures a higher energy-saving effect.
5 Fewer control valves required
A wide variety of control can be achieved by adjusting
2 Low noise
Low noise level of 60 dB (A)
parameter settings.
 Acceleration/deceleration operations that have been accomplished using
(In the pressure retained operation at 20.6 MPa, with the double pump type unit) proportional control valves may be replaced by simply setting the
Even over the full operation range, noise is less than 73 dB (A). acceleration/deceleration time.
 Pressure switch may be reduced by using the pressure switch function.
 By using double phase-differential pumps, the Super Unit reduces
pulsation and the noise level. (Note that some kinds of control are not applicable depending on the customer’s
* Data for SUTD60L21 circuit. Care must be taken especially when controlling multiple axes.)

1 Multi-stage pressure/flow rate control


3 Communication function
Functions

(Available as an option with all models)


Sixteen pressure (P) - flow rate (Q) setting
patterns are available for cylinder control. Remote control and setting changes are
 The proportional control valve and proportional pressure control valve, possible through RS232C serial communication.
which are utilized in conventional actuator circuits, can be omitted.  Using a commercially-available PLC or touch panel display with
 The pressure and flow rate can be set using the control unit’s RS232C communication capabilities, parameters for the pressure,
operation panel. flow rate, acceleration time, deceleration time and so on can be set
 The pressure and flow rate settings can be selected from among the and viewed at the machine. This facilitates control of speeds and
sixteen patterns using external input signals. pressurizing forces and enables a wide variety of machine
 The Super Unit autonomously switches between the pressure control operations.
and flow rate control modes.

2 Maintenance/Management Function (Hybrid-Win) 4 Analog command input


(Available as an option with single pump type models)
Internal data of the Super Unit PC tool
Enables continuous control of pressures and
can be obtained by using PC speeds as required.
connected to the unit. Supported
 The pressure and flow rate can be controlled continuously at the
 The pressure, flow rate, and other internal data of the controller can be desired values by inputting the pressure command voltage (0 to 10 V)
monitored and displayed in graph form. This facilitates operation and flow rate command voltage (0 to 10 V) from the machine side.
checks during test runs, adjustment of parameters such as time This achieves a control system with a simple configuration for
constants, and troubleshooting. machinery that requires variable speed control or continuity of
 The time required for setting can be slashed by editing the parameter pressurizing forces.
settings on the PC and writing them to the unit in a batch. The ability to
read and save settings facilitates management.

Super Unit hydraulic circuits (example for the unit type)


Example with SUT03S1507-30. Refer to the Instruction Example with SUT06D4016-30. Refer to the Instruction
Single pump type Manual for each model for details because the port Double pump type Manual for each model for details because the circuit
diameter varies depending on the model. configuration varies depending on the model.

P T Optional port DR Part No. Name P T Optional port DR Part No. Name
Rc⅜ Rc1 Rp⅜ Rp½ Rp3/4 1 Tank Rc¾ Rc1 Rc¾ Rp⅜ Rp½ Rp¾ 1 Tank
2 Suction strainer 9 2 Suction strainer
3 Stop valve 8 3 Stop valve
4 Oil filler port-cum-air breather 4 Oil filler port-cum-air breather
Above oil level
6-1 5 Oil level gauge 5 Oil level gauge
6-1 Above oil level
6-1 Controller 6-1 Controller
C/R 6-2 Motor pump incorporating an IPM motor
T P b
6-2 Motor pump incorporating an IPM motor
6-2 B A

M 7 Oil cooler 7 Oil cooler


7 Hose P1 (low pressure)
7 Hose P2 (high pressure) 8 Return filter
C/R
M 6-2 9 Check valve with holes
M
M

Hose Hose Hose


3 Hose Hose 3
Rc½

Rc½
1 2 4 5 1 2 4 5

06
Features Movie of Daikin Hybrid hydraulic unit
URL https://www.daikinpmc.com/en/mv/hybrid_features.html

With excellent energy-saving technology, the Super Unit can substantially


reduce electricity costs. The control system can be easily upgraded by
combining various Super Unit functions.
Feature
1 Energy-saving

 Excellent cost effectiveness with energy-saving ratio of 50%


(In pressure retained operation at 20.6 MPa)
 Through servo control of Daikin’s original high-efficiency IPM motor, the Super Unit ensures both a high response
speed and stable rotation speed control with fixed-displacement pumps. In pressure holding mode, the Super
Unit autonomously reduces the motor rotation speed to the minimum value required to hold the pressure, thus
ensuring energy savings of 50% or higher (compared with the conventional Daikin variable piston pump).
 The Super Unit can even provide an energy-saving effect with general industrial machinery in which
actuators provide a high duty ratio, as well as in pressure holding mode.

Existing hydraulic unit Super Unit


5 5
Power consumption (kW)

Power consumption (kW)


4 4

3 3

2 2

1 1

0 0
Operation time Operation time

 Comparison of annual
power consumption Power consumption Annual energy-saving effect
2.5 (average during operation) Decreased by
Power consumption (kW)

2.0 Approx. 64% reduction $1,050 (JPY105,000)


1.5 [Estimation conditions]
2.2 kWh  Existing hydraulic unit: Variable vane pump
1.0 (Double pump)
 Model of Super Unit: SUT10D8021
0.5
0.8 kWh  Cost of electricity: ¥15/kWh
 Annual operation time: 5,000 hours
0
Existing hydraulic unit Super Unit  1$: ¥100

 Suppression of the temperature rise enabled elimination of the conventionally installed fan
Other cooler, resulting in reduction of the power consumed by the fan cooler on top of the
energy-saving effect of the hydraulic unit itself.
Effects
 This is an environmentally friendly hydraulic unit with heat generation reduced, achieving
features including (1) prolonged hydraulic oil life, (2) downsized oil tank, from 150L to 100L,
(3) reduced waste oil disposal volume, and (4) reduced hydraulic oil costs.

Feature
2 Low noise

 Low noise level of 60 dB (A)


(In pressure retained operation at 20.6 MPa, with the double pump type unit)
Even over the full operation range, noise is less than 73 dB (A).
 Running the motor at the minimum required rotation speed in pressure holding mode achieves a remarkable noise level reduction.

 Examples of typical noise levels It is generally known that


ordinary conversation can be
In a subway train
In a bus or train dB conducted with a person one
90 meter away in an environment
Noisy office
Ordinary 80 at a noise level of 60 dB (A).
conversation
70
Full operation
Quiet park range 60
Low noise level
Suburban areas Double pump type in
at night pressure holding
50
mode at 20.6 MPa
Super unit 40

07
Feature
3 Excluded from high-efficiency motor regulations
 High-efficiency motor regulations came into effect in Japan in April 2015.
These regulations apply to the hydraulic units equipped with general motors
but the Super Units that incorporate a high-efficiency IPM motor are
excluded from them.
 Eliminates the need for replacement of motors for each destination
Advantages of using  Eliminates the need for design changes in accordance with
hybrid hydraulic units amendments to the regulations
 Reduces design changes to spare parts, and the maintenance workload

Feature
4 All models conforming to CE standards
 All models conform to the machinery directive, EMC directive, and low

Features
voltage directive.
This facilitates CE approval of the main machine.

Feature
5 Restricted oil temperature rise
 Restriction of the temperature rise of the hydraulic fluid is one of the effects
achieved by adopting Super Units. This generates the following advantages.
 Improved machining accuracy  Extended service life of packing and other sealing materials
Reduced thermal distortion Improved maintainability
improves the machining accuracy. Deterioration of the packing and other sealing materials that are made
of rubber, used for hydraulic valves and hydraulic cylinders, is restricted.
 Reduced air-conditioning heat load
The reduced heat load on the  Extended service life of the hydraulic fluid
air conditioner achieves further Reduced environmental load and improved maintainability
energy savings. Restricted deterioration of the hydraulic fluid extends its
replacement interval.

Feature
6 Fewer control valves required

 Example hydraulic press circuit configuration

Reducing the Number of


Control Valves by Creating a
Software-based System
Configuration

Throttle valve Elimination of


the throttle valve

Special spool shockless Use of General General-purpose


solenoid valve purpose solenoid valve solenoid valve

Elimination of the
proportional Combination flow/single
control valve flow switching valve

M M
Driver Control unit

Proportional relief valve

Conventional system configuration Super Unit system configuration

08
Functions Movie of multi-stage
pressure/flow rate control
URL https://www.daikinpmc.com/en/mv/hybrid_functions.html

Multi-stage pressure/flow rate control


Function
1 (16 PQ control setting patterns)
Featured with standard models

 The force (pressure) and speed (flow rate) of the actuator (cylinder) can be controlled
with 16 pressure (P) and flow rate (Q) setting patterns.
The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, are not
required. Once the pressure and flow rate have been set at the controller’s operation panel, you can select 16 preset patterns
using external input signals.
The Super Unit autonomously changes the control mode from flow rate control to pressure control (example: flow rate control is
changed to pressure control at the cylinder stroke end).
The solenoid valve that actuates the cylinder must be turned ON/OFF at the machine.

 Smooth changing of force (pressure) and speed (flow rate)


Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually during a
pressure/flow rate setting change.

Example of PQ control setting patterns

 PQ selection 0  PQ selection 1  PQ selection 2  PQ selection 3

PQ Pattern selection: 0 Pressure: MPa PQ Pattern selection: 1 Pressure: MPa PQ Pattern selection: 2 Pressure: MPa PQ Pattern selection: 3 Pressure: MPa

Speed (mm/s)
Pressurizing force (kN)
160

140
Pressurizing Cylinder speed
force
120
Deceleration low speed
100
Pressure release*
80

60

40 Lowered at
high speed Pressurizing Raised Meter-in control is
20 (3-stage pressuring) performed for pumps.

0
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0
PQ Time (sec)
PQ selection 0 PQ selection 1 selection 2 PQ selection 3 PQ selection 0
PQ pattern selection
*: When pressure release control is disabled, an additional pressure release circuit should be provided for the load side.

Function
2 Maintenance/Management function (Hybrid-Win) Featured with standard models

PC tool This PC utility reads data from Daikin hybrid systems (Super Unit,
EcoRich, oil cooling unit, etc.) and manages it. Parameter setting and
Supported
monitoring can be accomplished efficiently using the Windows application.

M a i n  Displaying graphs  Reading and saving the alarm history


The pressure, flow rate, and other internal data of the controller can This function enables quick identification of the parts that
features be monitored and displayed in graph form. This facilitates operation require maintenance and reduction of the downtime. The
checks during test runs, adjustment of parameters such as time operating time display can serve as the guide for the timing
constants, and troubleshooting. to replace consumable parts or to conduct maintenance.
Troubleshooting information including the diagnosis results of
 Reading, writing, editing, and saving parameters the cause of an alarm and action to take can be displayed.
The time required for setting can be slashed by editing the
parameter settings on the PC and writing them to the unit in a Communication
batch. The ability to read and save settings facilitates management. cable
*: Hybrid-Win is utility software to monitor the internal status of Daikin
hybrid systems using a PC. The software and its instruction manual
can be downloaded from the website “https://www.daikinpmc.com/en/”
free of charge by completing the user registration process.
*: The communication cable is separately available.
*: Some models require a dedicated separate monitor harness. PC
*: It is possible to connect to a smart phone or factory LAN by adding (to be prepared by the customer) Super Unit
an optional WiFi module. This is useful to facilitate the user’s daily
inspection/maintenance work and for remote monitoring.

09
Function Option

Optional
function C Communication function

Remote setting of operating conditions


 Operating condition setting of the SUPER UNIT possible from a distance
・Various settings such as acceleration/deceleration time and pressure switch settings, as well as the
pressure and flow rate, can be set remotely.
This makes it possible to control the hydraulic pressure operating conditions in synchrony with the
control of the machine.

IoT-ready
 Managing the pressure and flow rate from a machine
・The information that the SUPER UNIT outputs during machine operation, such as pressure and flow
rate, can be displayed on the monitor at a machine.
・By continuously collecting data from the SUPER UNIT, it is possible to determine machining faults,
diagnose machine failures, and utilize the data for predictive maintenance.
∗ RS232C is adopted for the serial communication interface. (For RS485, please consult us.)
Provide a controller such as a PLC or touch panel display with the RS232C communication function at the machine side.
∗ For details on the communication procedure, refer to the communication/remote control function instruction manual.

Functions
Function Option
Application of Super Unit Remote Operation
and Communication Functions

Installation in an
elevated position or at a
distance (within 15 m)

Setting and monitoring


P (pressure), Q (flow rate), and
other data from the machine
control panel

Optional
function P Analog command input

The capability to specify the pressure and flow rate with voltage
ranging from 0 to 10 V enables continuous hydraulic control as
required. Real-time variation in response to commands facilitates
condition settings at the machine side.
 A hydraulic control system for machinery that requires variable speed control or
continuity of pressurizing forces can be realized with a simple configuration.
 A joystick or trimmer can be connected for real-time control.

10
Hardware Option

Hardware
option 01 With unit cover

Optionally available for units with tank


capacities of 60 L, 100 L, and 160 L
(SUT06S3016-30 excluded)
 The cover protects the controller unit and
piping.

Hardware
option 02 With controller cover Example of unit
cover installation

Optionally available for models with


motor capacities equivalent to 2.2 kW, Example of
2.8 kW, 3.7 kW, and 5 kW controller cover
installation
 The metal cover protects the controller unit.

Hardware
option 03 With DCL (DC reactor)

Optionally available for models with motor capacities equivalent to 2.2 kW,
2.8 kW, 3.7 kW, and 5 kW
 Appropriate when it is necessary to improve the power factor or reduce the harmonics of the
power supply
 Optionally available for compact models with the capacity of 5 kW or smaller. Provided as
standard for models with a capacity of 7 kW or greater.

Hardware
option 04 Separate power supplies for power system and control system

Optionally available for units with motor capacities equivalent to 2.2 kW,
2.8 kW, 3.7 kW, 5 kW, and 7 kW
 When an error occurs, only the main power supply is shut down and control power supply
continues to carry current, thereby enabling the alarm code and internal status on occurrence
of an error to be checked on the operation panel or through serial communication.

Hardware
option 05 Water fill test compliant tank Hardware
option 06 Water leak test compliant tank

Optionally available with all unit type models


 The water fill test, one of the adaptation criteria for the Fire Service Act, and the water leak test,
Daikin original standard, are carried out. The tanks that pass the tests have compliance
nameplates affixed and are delivered with the certificate. (Water fill test compliant tanks are not
equivalent to Fire Service Act compliant tanks.)

11
Hardware
option 07 Level switch Hardware
option 08 Temperature switch
Hardware
option 09 Thermometer Hardware
option 10 Micro separator

Optionally available with all unit type models


 The accessories that can be fitted to the tank are provided as optional parts.
 The accessories can be purchased separately as optional parts. (See Page 44.)

List of Models with Options Installed

Function Option Hardware Option

Separated power
Pump Motor With unit With controller
Model code C P With DCL (03) supply for power/ Tank inspection/
specifications capacity cover (01) cover (02) control systems (04) unit accessory (*)
SUT00S1507-30 −    −
Equivalent to

Hardware Option
2.2kW SUT03S1507-30 −    

SUT00S3007-30 −    −

SUT03S3007-30 −    
Equivalent to
2.8 kW SUT00S1510-30 −    −

SUT03S1510-30 −    

SUT00S4007-30 −    −

SUT03S4007-30 −    
Single SUT00S3010-30 −    −
Equivalent to
pump 
3.7 kW SUT03S3010-30 −    

SUT00S1516-30 −    −

SUT03S1516-30 −    

SUT00S3016-30 −    −

SUT06S3016-30 −    
Equivalent to
5.0 kW SUT00S6007-30 −    −

SUT06S6007-30     

SUT00S8007-30 − − −  −
Equivalent to
7.0 kW SUT10S8007-30  − −  

SUT00D4016-30 −    −
Equivalent to
3.7 kW SUT06D4016-30     

SUT00D6021-30 −    −
Double Equivalent to SUT06D6021-30     
pump 5.0 kW –
SUT10D6021-30     

SUT00D8021-30 − − −  −
Equivalent to SUT10D8021-30  − −  
7.0 kW
SUT16D8021-30  − −  

* Tank inspections : Water fill test compliant tank (05), water leak test compliant tank (06)  Available – Not available
Unit accessories : Level switch (07), temperature switch (08), thermometer (09), microseparator (10)

12
Pressure – Flow Rate Characteristics (Typical)

Single pump type

SUTS1507, SUTS3007, SUTS4007,


SUTS6007, SUTS8007, SUTS11007

110
SUTS11007
100
90
80 SUTS8007
Flow rate (L/min)

70
60 SUTS6007

50
* Operating flow rate at the maximum
40 SUTS4007
pressure in continuous operation:
30 SUTS3007 SUTS1507: 3 L/min maximum
SUTS3007: 5 L/min maximum
20 SUTS1507
SUTS4007: 8 L/min maximum
10 SUTS6007: 14 L/min maximum
SUTS8007: 19 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS11007: 16 L/min maximum
Pressure (MPa)

SUTS1510, SUTS3010

90
80
70
Flow rate (L/min)

60
50
40
30
SUTS3010
20 SUTS1510
* Operating flow rate at the maximum
10 pressure in continuous operation:
SUTS1510: 3 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS3010: 5 L/min maximum
Pressure (MPa)

SUTS3016, SUTS1516

90
80
70
Flow rate (L/min)

60
50
40
30
SUTS3016
20 SUTS1516
* Operating flow rate at the maximum
10
pressure in continuous operation:
SUTS1516: 5 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS3016: 5 L/min maximum
Pressure (MPa)

13
Double pump type

SUTD4016 SUTD6021

110 110

100 100

90 90

80 80

70 70
Flow rate (L/min)

Flow rate (L/min)


60 60

50 50

40 40

30 30

20 20

10 10

Pressure – Flow Rate Characteristics (Typical)


0 0
0 5 10 15 20 0 5 10 15 20
Pressure (MPa) Pressure (MPa)

* Operating flow rate at the maximum pressure in continuous operation: * Operating flow rate at the maximum pressure in continuous operation:
8 L/min maximum 6.5 L/min maximum

SUTD8021 SUTD11021

110 110

100 100

90 90

80 80

70 70
Flow rate (L/min)

Flow rate (L/min)

60 60

50 50

40 40

30 30

20 20

10 10

0 0
0 5 10 15 20 0 5 10 15 20
Pressure (MPa) Pressure (MPa)

* Operating flow rate at the maximum pressure in continuous operation: * Operating flow rate at the maximum pressure in continuous operation:
14 L/min maximum 16 L/min maximum

14
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 15/30 L/min 110
SUTS11007
Model code 100

SUTS1507-30 90

SUTS3007-30 80 SUTS8007

70

Flow rate (L/min)


60 SUTS6007

50
40 SUTS4007

30 SUTS3007

20 SUTS1507
10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Motor pump type Pressure (MPa)
* The graph shows actual flow rates (representative values).
Unit type
* Operating flow rate at the maximum pressure in continuous operation:
SUTS1507: 3 L/min maximum
SUTS3007: 5 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S1507-30 SUT00S3007-30 SUT03S1507-30 SUT03S3007-30
Maximum operating
7.0
pressure (MPa)
Operating pressure
1.5 to 7.0
adjustment range (MPa)
Pump
Maximum flow rate
15.2 28.5 15.2 28.5
(theoretical value) (L/min)∗1
Operating flow rate
2.5 to 15.2 3.5 to 28.5 2.5 to 15.2 3.5 to 28.5
adjustment range (L/min)
Motor capacity
Motor 2.2 2.8 2.2 2.8
(equivalent kW)
Tank capacity (L) − 30
Power supply
Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
voltage
AC3 φ 200 V (50 Hz) 11.5 15.4 11.5 15.4
Rated current
AC3 φ 200 V (60 Hz) 11.3 15.1 11.3 15.1
(A)
AC3 φ 220 V (60 Hz) 10.6 13.8 10.6 13.8
No-fuse breaker capacity (A) 15 20 15 20
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
General petroleum-based hydraulic oil (R&O) / Wear-resistant hydraulic oil
Usable oil ∗2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Tank oil temperature 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
Operating ambient temperature 0 to 40°C
Storage ambient temperature −20 to 60°C
Operating ambient humidity 85% RH maximum (No condensation)
Operating
conditions Waterproof protection rating (Controller) IP44
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the controller’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.

Standard coating color Ivory white (Munsell code 5Y7.5/1)


Mass (kg) 37 39 59
Note) *1: The pump flow rate has been factory-set to the maximum flow rate. The maximum flow rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult DAIKIN about the use of hydraulic oils other than petroleum-based oil (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a SUPER UNIT, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for SUPER UNITs.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

15
External Dimension Diagram

Motor pump type


Pressure indication and operation panel P Rc⅜
(Fitted with a vinyl cap at shipment)

15
SUT00S1507-30
SUT00S3007-30

(254)
Part No. Name Quantity

344
314
1-1 Motor pump incorporating an IPM motor 1

(162)
1-2 Controller 1
2 AC fan 1
4-φ10 holes (for fixing bolts)
(87)
3 Base 1 (M8 bolts recommended)

15
15 490 15
520

φ28 hole φ21 hole


(Power cable port) (Signal cable port) 1-2

DR Rc⅜
(83) (Fitted with a vinyl cap at shipment)
(421)

Wing bolt for fastening during Unit nameplate


(466)

transportation (at 1 location) ********


(To be removed before operation) Suction Safety caution Unit nameplate 1-1
air nameplate
Safety caution

(260)
(246)
nameplate
(220)

(109)
45
45

Suction port: G¾
30 284 30

Specifications/External Dimension Diagram


30 460 30
(Fitted with a vinyl cap at shipment)
344 520
3

Unit type DR Rp¾ (above oil level)


(Fitted with a vinyl cap at shipment)
Optional port: Rp½
132.5 550 SUT03S1507-30
(175)
(75) 150 170 SUT03S3007-30
42

50

Part No. Name Quantity


92

4-M8
(Manifold bracket mount) 1 Oil tank 1
100

T Rc1 (Manifold bracket mount)


(Fitted with a vinyl cap at shipment) 2 Suction strainer 1
Optional port: Rp⅜ 3 3 Stop valve 1
P Rc⅜
4 Oil level gauge 1
7
(Fitted with a vinyl cap at shipment)

5 Oil filter port-cum-air bleeder 1


MPa
6-1 Motor pump incorporating an IPM motor 1
140

6-2 Controller 1
Pressure indication and
operation panel
196
Foundation plate (Option)
(E-SUTPLATE-2)
7 Oil cooler 1 15/
(40) (620) (40) 4-φ15 holes (for fixing bolts)
(M12 bolts recommended)
8 AC fan 1 30
L/min
6-2 5 4
φ21 hole Cleaning port

(Signal cable port)

30 L
φ28 hole Safety caution Upper limit (Yellow line) 1
(Power cable port) nameplate Cleaning port tightening caution nameplate
SUT03S15L07-30
23 L
Unit nameplate 2
7 Lower limit (Red line)

Suction air
462
(516)

6-1
419

Oil sampling port/


Oil drain port: Rc½
309

8
20

ボルト
注意銘板
95

70

(50)

155
70
40

450
25

20 10 30 30
500
85 530 85
(550)
700
Wing bolt for fastening during transportation (580)
2-M8 (through hole)
(at 1 location on the back) Tapped holes for mounting
(To be removed before operation) the foundation plate
(at 4 locations)

16
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 40 L/min 110
SUTS11007
Model code 100

SUTS4007-30 90
80 SUTS8007

70

Flow rate (L/min)


60 SUTS6007

50
40 SUTS4007

30 SUTS3007

20 SUTS1507
10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Pressure (MPa)

* The graph shows actual flow rates (representative values).


Unit type
* Operating flow rate at the maximum pressure in continuous operation:
8 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S4007-30 SUT03S4007-30

Maximum flow rate


39.7
(theoretical value; L/min) *1
Maximum operating
7.0
pressure (MPa)
Pump unit
Operating flow rate
5.3 to 39.7
adjustment range (L/min)
Operating pressure
1.5 to 7.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 3.7 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 16.1
Rated current
AC3 φ200V (60 Hz) 15.8
(A)
AC3 φ220V (60 Hz) 14.8
Power source breaker setting (A) 20
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 64
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

17
External Dimension Diagram

P Rc½
Motor pump type (Fitted with a vinyl cap at shipment)
Pressure indication and operation panel

15
SUT00S4007-30

Part No. Name Quantity

(294)
384
354
1-1 Motor pump incorporating an IPM motor 1

(202)
1-2 Controller 1
2 AC fan 1
3 Base 1 4-φ10 holes (for fixing bolts)
(87) (M8 bolts recommended)

15
15 490 15
520

φ28 hole φ21 hole


(Power cable port) 1-2
(Signal cable port)

DR Rc⅜
(83) (Fitted with a vinyl cap at shipment)
(421)

Suction
Unit nameplate
(466)

air
Suction air Safety caution
Wing bolt for fastening during nameplate 1-1
transportation (at 1 location)

(259)
(245)
220

(To be removed before operation)


2

(108)
45
45

Specifications/External Dimension Diagram


Suction port: G¾
30 460 30
30 324 30 (Fitted with a vinyl cap at shipment)
3
520
384

Unit type

T Rc1 DR Rp¾ (above oil level)


(Fitted with a vinyl cap at shipment) (Fitted with a vinyl cap at shipment)
132.5 550 SUT03S4007-30
177.5
77.5 150 170

Part No. Name Quantity


42

50
92

1 Oil tank 1
4-M8
100

(Manifold bracket
(Manifold bracket mount)
mount)
2 Suction strainer 1

3 3 Stop valve 1
Optional port: Rp½
4 Oil level gauge 1
Optional port: Rp⅜
5 Oil filler port-cum-air breather 1 7
MPa
P Rc½ 6-1 Motor pump incorporating an IPM motor 1
(Fitted with a vinyl cap at shipment)
6-2 Controller 1
140.5

Foundation plate (Option) 7 Oil cooler 1


Pressure indication and
operation panel 196
(E-SUTPLATE-2)
8 AC fan 1
40
4-φ15 holes (for fixing bolts) L/min
(40) (620) (40)
(M12 bolts recommended)
6-2
φ21 hole Cleaning port
(Signal cable port) 5 4

30 L 1
φ28 hole Safety caution
Safety caution Upper limit (Yellow line)
nameplate
(Power cable port) nameplate Cleaning port tightening caution nameplate
EHU40R-M0703-30
EHU40R-M0703-30 23 L
Unit nameplate
Lower limit (Red line) 2
7
(516)

462

Suction air
6-1
419

Oil sampling port/


(309)

8 Oil drain port: Rc½


20

Bolt
Caution nameplate
95

155
(50)
70

70
40

2-M8 (through hole)


Tapped holes for mounting the 450
25

20 10 foundation plate (at 4 locations) 30 30


85 530 85 500
700 (550)
Wing bolt for fastening during transportation (580)
(at 1 location on the back)
(To be removed before operation)

18
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 60 L/min 110
SUTS11007
Model code 100

SUT00S6007-30 90

SUT06S6007-30 80 SUTS8007

70

Flow rate (L/min)


60 SUTS6007

50:
40 SUTS4007

30 SUTS3007

20 SUTS1507
10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Pressure (MPa)

* The graph shows actual flow rates (representative values).


Unit type
* Operating flow rate at the maximum pressure in continuous operation:
14 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S6007-30 SUT06S6007-30

Maximum flow rate


61.1
(theoretical value; L/min) *1
Maximum operating
7.0
pressure (MPa)
Pump unit
Operating flow rate
8.7 to 61.1
adjustment range (L/min)
Operating pressure
1.5 to 7.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 5.0 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 22.1
Rated current
AC3 φ200V (60 Hz) 21.7
(A)
AC3 φ220V (60 Hz) 20.2
Power source breaker setting (A) 30
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 56 97
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

19
External Dimension Diagram

Motor pump type


Unloading port Rc½
Pressure indication and operation panel (Fitted with a vinyl cap at shipment)
(140) P Rc¾

15
(Fitted with a vinyl cap at shipment)
SUT00S6007-30

(73)
Part No. Name Quantity
1-1 Motor pump incorporating an IPM motor 1

(294)
384
354
1-2 Controller 1

(180)
2 AC fan 1

(95)
3 Base 1
4-φ10 holes (for fixing bolts)
4 Check valve 1 (136)
(M8 bolts recommended)

15
15 578 15
608

φ28 hole φ21 hole


(Power cable port) (Signal cable port) 1-2

DR Rc⅜
(Fitted with a vinyl cap at shipment)
(421)

(466)

Unit nameplate
Suction ********
air Safety caution
Unit nameplate
Wing bolt for fastening during nameplate 1-1

(282)
transportation (at 1 location) Safety caution
(241)

(226)
(To be removed before operation) nameplate
2

(95)
45

30 324 30 (86)

Specifications/External Dimension Diagram


3
(143)
384 30 548 30
608
Suction port: Rc1
(Fitted with a vinyl cap at shipment)

Unit type
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
85 100 327 188
T Rc1
(Fitted with a vinyl cap at shipment)
150 170
SUT06S6007-30
37
42

50

4-M8 Part No. Name Quantity


110

(Manifold bracket mount)


100

1 Oil tank 1
(311)

T Rc¾ 2 Suction strainer 1


(Plugged at shipment) 3 Stop valve 1
Optional port: Rp⅜ 4 Oil level gauge 1
3
Optional port: Rp½ 5 Oil filler port-cum-air breather 1

P Rc¾
6-1
6-2
Motor pump incorporating an IPM motor
Controller
1
1
7
(Fitted with a vinyl cap at shipment) 7 Oil cooler 1
MPa
Foundation plate (Option) 8 AC fan 1
4-φ15 holes (for fixing bolts) Pressure indication and operation panel (E-SUTPLATE-2) 9 Return filter 1
(M12 bolts recommended) 10 Check valve 1
(40) (620) (40)
60
L/min
4 1
9 5
6-2 10

60 L
Safety
Unit nameplcaution
ate Upper limit (Yellow line)
nameplate
Safety caution
nameplate
Unit nameplate 45 L
Lower limit (Red line)

Cleaning port tightening caution nameplate 2


648

6-1
639
716

7
595

Cleaning port
Suction
(441)

air

8
20

Bolt
Caution nameplate
95

70
70

(50)

Wing bolt for fastening during 155


40

transportation (at 1 location on the back)


Oil sampling port/
20 10 (To be removed before operation) 30 30 450
25

Oil drain port: Rc½


85 530 85 2-M8 (through hole) 500
(707)
Tapped holes for mounting the foundation plate
(at 4 locations)

20
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 80 L/min 110
SUTS11007
Model code 100

SUTS8007-30 90
80 SUTS8007

70

Flow rate (L/min)


60 SUTS6007

50
40 SUTS4007

30 SUTS3007

20 SUTS1507
10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Pressure (MPa)

* The graph shows actual flow rates (representative values).


Unit type
* Operating flow rate at the maximum pressure in continuous operation:
19 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S8007-30 SUT10S8007-30

Maximum flow rate


83.0
(theoretical value; L/min) *1
Maximum operating
7.0
pressure (MPa)
Pump unit
Operating flow rate
11.6 to 83.0
adjustment range (L/min)
Operating pressure
1.5 to 7.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 7.0 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 25.5
Rated current
AC3 φ200V (60 Hz) 24.8
(A)
AC3 φ220V (60 Hz) 22.7
Power source breaker setting (A) 50
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 72 131
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 100
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

21
External Dimension Diagram

Motor pump type


Pressure indication and
Motor cable operation panel
(139)

15
SUT00S8007-30 P Rc¾
(Fitted with a vinyl cap at shipment)

Unloading port: Rc½


Part No. Name Quantity (Fitted with a vinyl cap at shipment)

294
1-1 Motor pump incorporating an IPM motor 1

384
354
1-2 Controller 1

(196)
2 AC fan 1

(125)
3 Base 1
4 Check valve 1 4-φ10 holes (for fixing bolts)
(135) (M8 bolts recommended)

15
15 600 15
(60) 630

1-2

4 DR Rc⅜
(Fitted with a vinyl cap at shipment)

1-1
(441)

(486)

Unit
nameplate

(408)
Suction air (85.5)
Safety caution

(300)
(244)
nameplate
(260)

(90)
Transportation nameplate
45

Specifications/External Dimension Diagram


30 324 30 Suction port: Rc1
3 (142) (Plugged (with O-ring) at shipment)
30 570 30
Wing bolt for fastening
during transportation (at 2 locations)
(To be removed before operation)

Unit type
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
T Rc1-½ (85) 100 (327) (188)
(Fitted with a vinyl cap at shipment)
150 170 SUT10S8007-30
17

100 50

Part No. Name Quantity


150
172

1 Oil tank 1
2 Suction strainer 1
3 Stop valve 1
(439)

4-M8
T Rc1-¼ (Manifold bracket mount) 4 Oil level gauge 1
(Plugged at shipment)
5 Oil filler port-cum-air breather 1
Pressure indication and operation panel
Optional port: Rp⅜
3 6-1
6-2
Motor pump incorporating an IPM motor
Controller
1
1
7
7 Oil cooler 1
MPa
Optional port: Rp½
P Rc¾
8 AC fan 1
4-φ15 holes (for fixing bolts) (Fitted with a vinyl cap
at shipment) 9 Return filter 1
(M12 bolts recommended)
10 Check valve 1
80
(40) (620) (40)
Foundation plate (Option)
(E-SUTPLATE-2) Cleaning port L/min

6-2 9 4
5

SUT10D80L07-30 100 L
10 Unit nameplate Upper limit
Safety
Safetycaution
caution (Yellow line)
nameplate
nameplate
7 76 L
Lower limit
754

(Red line)
8
671

(647)

Cleaning port tightening caution nameplate


6-1
595

1
(441)

Suction
air 2
(216)

20

Bolt
Caution nameplate
95

155
70
70

(50)
40

20 10 30 30 2-M8 (through hole) 450 50 80


25

85 530 85 580
Tapped holes for mounting
(188) 700 630
the foundation plate (at 4 locations)
(895) Oil sampling port/
Oil drain port: Rc½
Wing bolt for fastening during transportation (at 1 location on the back)
(To be removed before operation)

22
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 110 L/min 110
SUTS11007
Model code 100

SUT00S11007-40 90
80 SUTS8007

70

Flow rate (L/min)


60 SUTS6007

50
40 SUTS4007

30 SUTS3007

20 SUTS1507
10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pressure (MPa)
Motor pump type
* The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
16 L/min maximum

Motor pump type


Specifications Model code SUT00S11007-40

Maximum flow rate


110
(theoretical value; L/min) *1
Maximum operating
7.0
pressure (MPa)
Pump unit
Operating flow rate
13.3 to 110
adjustment range (L/min)
Operating pressure
1.5 to 7.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 11.0 kW
(equivalent kW)
Power supply Motor pump 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 38.3
Rated current
AC3 φ200V (60 Hz) 37.8
(A)
AC3 φ220V (60 Hz) 34.9
Power source breaker setting (A) 75
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 112
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) −
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

23
External Dimension Diagram

Motor pump type Grease nipple (A-PT ⅛ type)


Suction port: Rc1-¼
819

SUT00S11007-40 Encoder wiring connector

87
SUT00S--A-
MFG No.: Note 1.
INSULATION CLASS: F

151
MASS : 88 kg
V Hz A PF
MAX. FLOW : 80 L/min 3φ 200 50: 62 0.94
MAX.PRESSURE : 17.6 MPa 3φ 200 60 62 0.94
3φ 220 60 61 0.94
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

Motor wiring port (φ28)

AC fan, thermistor wiring port (φ21)


Drain port
Rc⅜
323
168 496
117 204 42 118
19
Unloading port
Discharge port Rc¾
Rc1-¼

■■■■■■■■■■■■■■
■■■■■■■■■■■■■■

■■■■■■■■■■■■
■■■■■■■■■■■■

Suction
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
**

air
D □EC

IN C

261

243
228

207
170
129

112
95

4-14.5 (Installation)
15

108 108 76.5 95.5 132.5

Specifications/External Dimension Diagram


241 228
275

Control unit

SUT00S11007-40 Cooling fan Cooling fan

SUT00D11021-40
Controller (Installed separately)

Controller installation hole


4-φ8 (M6 bolts recommended)

<Top>
11.5

7
180
Cooling fan
exhaust
User I/O terminal (M3)
MPa
34

• Encoder
• Motor thermistor
• Pressure sensor
FG
FG
GND
+5V

• I/O signal Z+
Z-
Operation panel
110
危 険
B- WARNING
B+
A- 感電のおそれがあります。
A+ ・通電中及び電源遮断後5分以内は
ターミナルカバーを開けないで下さい。
THM- May cause
THM+ electric shock.
AGND
L/min
AO2 ・Disconnect all power
before opening terminal
(QO)AGND cover of unit.
AO1 Wait 5 minutes until
DC Bus capacitors
(PO) dischange.

Product nameplate
DAIKIN INDUSTRIES,LTD.
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
A5V
233

ALM_C
ALM_B
ALM_A

Main power supply


DOCOM MFG No.:
DO7
DO6 MASS : kg INSULATION CLASS:A F PF
V Hz
DO5
terminal block (M5)
MAX. FLOW : L/min 3φ 200 50
DO4 MAX.PRESSURE: MPa 3φ 200 60
DO3
378.5

3φ 220 60
361

DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

• Main power supply


327.5

DO2
DO1
DI8

• DC reactor
DI7
DI6
DI5
DI4
DI3
DI1
DI2 • Regenerative resistor
DGND
DICOM
RxD
• Motor output
TxD
FG
FG
Electromagnetic valve
Controller nameplate terminal block (M4)
M5 screw • Electromagnetic valve power supply
(for ground connection) • AC fan power supply

M4 screw (for ground connection)


95.5

M5 screw (for ground connection)

39
Cooling fan 25 180 (25)
6
17

suction
207 (5) (5) 230 (5)
212 240

24
Super Unit
[Single pump type]
Maximum
operating
pressure 10 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 15 L/min
90
Model code
80
SUTS1510-30
70

Flow rate (L/min)


60

50

40

30 SUTS3010

20 SUTS1510

10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Pressure (MPa)
Unit type
* The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
3 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S1510-30 SUT03S1510-30

Maximum flow rate


15.2
(theoretical value; L/min) *1
Maximum operating
10.0
pressure (MPa)
Pump unit
Operating flow rate
2.5 to 15.2
adjustment range (L/min)
Operating pressure
1.5 to 10.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 2.8 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 8.0
Rated current
AC3 φ200V (60 Hz) 7.8
(A)
AC3 φ220V (60 Hz) 7.5
Power source breaker setting (A) 15
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 39 59
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

25
External Dimension Diagram

Motor pump type


P Rc⅜
(Fitted with a vinyl cap at shipment)
Pressure indication and operation panel
SUT00S1510-30

15
Part No. Name Quantity
1-1 Motor pump incorporating an IPM motor 1

(254)
344
314
1-2 Controller 1

(162)
2 AC fan 1
3 Base 1
4-φ10 holes (for fixing bolts)
(M8 bolts recommended)

15
(87)
φ28 hole 15 490 15
(Power cable port) φ21 hole
(Signal cable port) 520
1-2

DR Rc⅜
(Fitted with a vinyl cap
at shipment)
(83)
(421)

Wing bolt for fastening during


(466)

Unit nameplate
transportation (at 1 location) Suction
(To be removed before operation) air Safety caution 1-1
nameplate

(260)
(246)
(220)

(109)
45
45

Suction port: G¾
3 (Fitted with a vinyl cap
30 284 30 30 460 30
at shipment)
344
520

Specifications/External Dimension Diagram


Unit type DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)

Optional port: Rp½


132.5 550
177.5
77.5 150 170 SUT03S1510-30
42

50
92

4-M8 Part No. Name Quantity


4-M8
100

T Rc1 (Manifold
(Manifoldbracket mount)
bracket mount)
1 Oil tank 1
(Fitted with a vinyl cap
at shipment) 2 Suction strainer 1
3
Optional port: Rp⅜
P Rc⅜ 3 Stop valve 1
(Fitted with a vinyl cap at shipment)
4 Oil level gauge 1
5 Oil filter port-cum-air bleeder 1
140.5

6-1 Motor pump incorporating an IPM motor 1

Pressure indication and


Foundation plate (Option)
6-2
7
Controller
Oil cooler
1
1
10
operation panel 196 (E-SUTPLATE-2) MPa
(40) (620) (40) 4-φ15 holes (for fixing bolts)
8 AC fan 1
(M12 bolts recommended)

6-2 5 4
φ21 hole
(Signal cable port)
Cleaning port
15
L/min

φ28 hole 30 L
Safety caution
(Power cable port) nameplate Upper limit (Yellow line) 1
Cleaning port tightening caution nameplate
SUT03S15L10-30 23 L
Unit nameplate 2
7 Lower limit
(Red line)
(516)

462

Suction air
6-1
419

Oil sampling port/


309

Oil drain port: Rc½


8
20

Bolt
Caution nameplate
95

155
70
70
40

20 10 30 30 450
25

85 530 85 500
700 (550)
Wing bolt for fastening during transportation 2-M8 (through hole) (580)
(at 1 location on the back)
(To be removed before operation) Tapped holes for mounting
the foundation plate (at 4 locations)

26
Super Unit
[Single pump type]
Maximum
operating
pressure 10 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 30 L/min
90
Model code
80
SUTS3010-30
70

Flow rate (L/min)


60

50

40

30 SUTS3010

20 SUTS1510

10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Pressure (MPa)

Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
5 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S3010-30 SUT03S3010-30

Maximum flow rate


25.6
(theoretical value; L/min) *1
Maximum operating
10.0
pressure (MPa)
Pump unit
Operating flow rate
3.4 to 25.6
adjustment range (L/min)
Operating pressure
1.5 to 10.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 3.7 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 18.4
Rated current
AC3 φ200V (60 Hz) 18.4
(A)
AC3 φ220V (60 Hz) 16.9
Power source breaker setting (A) 20
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 64
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

27
External Dimension Diagram

Motor pump type


Pressure indication and
operation panel P Rc⅜
(Fitted with a vinyl cap at shipment)

15
SUT00S3010-30

Part No. Name Quantity

(294)
1-1 Motor pump incorporating an IPM motor 1

384
354
1-2 Controller 1

(202)
2 AC fan 1
3 Base 1
4-φ10 holes (for fixing bolts)
(87) (M8 bolts recommended)

15
15 490 15
520

φ28 hole φ21 hole 1-2


(Power cable port) (Signal cable port)

DR Rc⅜
(Fitted with a vinyl cap at shipment)

(83)
(421)

(466)

Unit nameplate
Suction
Safety caution
Wing bolt for fastening during air
nameplate 1-1
transportation (at 1 location)

(259)
(245)
220

(To be removed before operation) 2

(108)
45

3 Suction port: G¾
30 324 30 30 460 30 (Fitted with a vinyl cap at shipment)

384 520

Specifications/External Dimension Diagram


Unit type
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)

132.5 550
177.5
150 170
SUT03S3010-30
77.5
42

50

Part No. Name Quantity


92

4-M8
1 Oil tank 1
100

(Manifold bracket mount)


T Rc1
(Fitted with a vinyl cap 2 Suction strainer 1
at shipment) Optional port: Rp½
Optional port: Rp⅜ 3 Stop valve 1
3
4 Oil level gauge 1
P Rc⅜
(Fitted with a vinyl cap at shipment) 5 Oil filler port-cum-air breather 1
6-1 Motor pump incorporating an IPM motor 1
140

Foundation plate (Option)


6-2
7
Controller
Oil cooler
1
1
10
Pressure indication and (E-SUTPLATE-2) MPa
operation panel 196 4-φ15 holes (for fixing bolts)
(40) 8 AC fan 1
(620) (40) (M12 bolts recommended)

6-2
Cleaning port
φ21 hole
(Signal cable port) 5 4 30
L/min
1
Safety 30 L
φ28 hole Safety caution
caution Upper limit (Yellow line)
nameplate
nameplate
(Power cable port) Cleaning port tightening caution nameplate
SUT03S30L10-30
23 L
Unit nameplate
7 Lower limit
(Red line)
(516)

462

Suction air
419

6-1
(309)

8 2
20

Bolt
ボルト
Caution
注意銘板 nameplate
95

155
70

(50)
70
40

20 10 30 30
25

450 Oil sampling port/


85 530 85
500 Oil drain port: Rc½
700
(550)
Wing bolt for fastening during transportation 2-M8 (through hole)
(at 1 location on the back) (580)
Tapped holes for mounting the foundation plate
(To be removed before operation)
(at 4 locations)

28
Super Unit
[Single pump type]
Maximum
operating
pressure 16 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 15/30 L/min
90
Model code
80
SUTS1516-30
SUTS3016-30 70

Flow rate (L/min)


60

50

40

30
SUTS3016
20
SUTS1516

10

Motor pump type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Pressure (MPa)
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
5 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00S1516-30 SUT00S3016-30 SUT03S1516-30 SUT06S3016-30

Maximum flow rate


15.2 25.6 15.2 25.6
(theoretical value; L/min) *1
Maximum operating
16.0
pressure (MPa)
Pump unit
Operating flow rate
2.4 to 15.2 3.4 to 25.6 2.4 to 15.2 3.4 to 25.6
adjustment range (L/min)
Operating pressure
1.5 to 16.0
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 3.7 kW Equivalent to 5.0 kW Equivalent to 3.7 kW Equivalent to 5.0 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 15.2 21.4 15.2 21.4
Rated current
AC3 φ200V (60 Hz) 15.2 21.4 15.2 21.4
(A)
AC3 φ220V (60 Hz) 14.6 20.2 14.6 20.2
Power source breaker setting (A) 20 30 20 30
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 52 64 83
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
29
External Dimension Diagram

Pressure indication and P Rc⅜


operation panel
Motor pump type

15
(Fitted with a vinyl cap at shipment)

SUT00S1516-30

(294)
384
354
SUT00S3016-30

(202)
Part No. Name Quantity
Motor pump incorporating 4-φ10 holes (for fixing bolts)
1-1 1 φ28 hole φ21 hole (137) (77)
an IPM motor 15 578 (490) 15 (M8 bolts recommended)

15
(Power cable port) (Signal cable port) 608 (520)
1-2 Controller 1
1-2
2 AC fan 1
DR Rc⅜
3 Base 1 (Fitted with a vinyl cap at shipment)
(133) (73)

(421)

(466)
Unit nameplate
Suction Safety caution
********

Wing bolt for fastening during air Unit nameplate


nameplate 1-1
transportation (at 1 location)

(260)
Safety caution

(245)
2 nameplate

220
(To be removed before operation)

(109)
3
(45)

45
30 324 30 30 548 (460) 30
384 608 (520) Suction port: G¾
(Fitted with a vinyl cap
at shipment)
Unit type 132.5 550
(): Dimensions for SUT00S1516-30
DR Rp¾ (above oil level) 177.5 4-M8
150 170
(Fitted with a vinyl cap at shipment) (Manifold bracket mount)
77.5
42

100 50

SUT03S1516-30
92

T Rc1
(Fitted with a vinyl cap Optional port: Rp½
at shipment)
Optional port: Rp⅜ 3
Part No. Name Quantity P Rc⅜
(Fitted with a vinyl cap at shipment)
1 Oil tank 1
140

2 Suction strainer 1 Pressure indication and


operation panel Foundation plate (Option)
3 Stop valve 1 4-φ15 holes (for fixing bolts) 186 (E-SUTPLATE-2)
(M12 bolts recommended) (40) (620) (40)
4 Oil level gauge 1
φ21 hole 6-2 5 4
Cleaning port

Specifications/External Dimension Diagram


5 Oil filler port-cum-air breather 1 (Signal cable port)

Motor pump incorporating φ28 hole


6-1 1 (Power cable port) 30 L 1
an IPM motor Safety caution
nameplate Upper limit (Yellow line)
7 SUT03S15L16-30

6-2 Controller 1
(516)

23 L
Suction Lower limit 462
419

7 Oil cooler 1 air (Red line)


(309)

2
8 6-1
8 AC fan 1
20

95

155
70

70

(50)
40

20 10 30 30
25

450
85 530 85 2-M8 (through hole)
500
700 Tapped holes for mounting
Wing bolt for fastening during transportation the foundation plate (at 4 locations) Oil sampling port/
(at 1 location on the back) Oil drain port: Rc½
(To be removed before operation)
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
SUT06S3016-30 T Rc1
(Fitted with a vinyl cap at shipment)
85 100 186
4-M8
150 170
(Manifold bracket mount)
37
42

100 50

Part No. Name Quantity


110

T Rc¾
(360)

1 Oil tank 1 (Plugged at shipment)


2 Suction strainer 1 Optional port: Rp⅜
Optional port: Rp½
3
16
3 Stop valve 1 MPa
Pressure indication and operation panel P Rc⅜
4 Oil level gauge 1 (Fitted with a vinyl cap at shipment)
4-φ15 holes (for fixing bolts)
Foundation plate (Option)
5 Oil filler port-cum-air breather 1 (M12 bolts recommended) (40)

Motor pump incorporating


(620) (40) (E-SUTPLATE-2)
4 15/
6-1
an IPM motor
1 9 6-2 5
30
60 L L/min
6-2 Controller 1 Unit nameplate
Upper limit (Yellow line)
Safety caution
7 Oil cooler 1 nameplate 45 L
Lower limit (Red line)
8 AC fan 1 6-1 Cleaning port
648

7
639
716
595

9 Return filter 1
Suction air 1
8
309

2
20

95

155
70

70

(50)
40

20 10 30 30 450 Oil sampling port/


25

Wing bolt for fastening during transportation 85 530 85 500 Oil drain port: Rc½
(at 1 location on the back) 2-M8 (through hole)
700
(To be removed before operation) Tapped holes for mounting the
foundation plate (at 4 locations)

30
Super Unit
[Double pump type]
Maximum
operating
pressure 16 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 40 L/min 110
Model code 100

SUTD4016-30 90
80

Flow rate (L/min)


70
60
50
40
30
20
10
0
Motor pump type
0 5 10 15 20
Pressure (MPa)

Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
8 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00D4016-30 SUT06D4016-30

Maximum flow rate


41.0 (41.0 for combination flow, 16.0 for independent flow)
(theoretical value; L/min) *1
Maximum operating
15.7
pressure (MPa)
Pump unit
Operating flow rate
5.4 to 41.0
adjustment range (L/min)
Operating pressure
1.5 to 15.7
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 3.7 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 17.9
Rated current
AC3 φ200V (60 Hz) 17.7
(A)
AC3 φ220V (60 Hz) 16.5
Power source breaker setting (A) 20
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 53 94
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
31
External Dimension Diagram

Motor pump type


Unloading port Rc½
Pressure indication and operation panel
(Fitted with a vinyl cap at shipment)

(146) P Rc¾

15
(Fitted with a vinyl cap at shipment)
SUT00D4016-30

(73)
Part No. Name Quantity

(294)
1-1 Motor pump incorporating an IPM motor 1

384
354
1-2 Controller 1

(180)
2 AC fan 1

(95)
3 Base 1
4-φ10 holes (for fixing bolts)
4 Check valve 1 (142) (M8 bolts recommended)

15
15 578 15
φ28 hole φ21 hole 608
(Power cable port) (Signal cable port)
1-2

4 DR Rc⅜
(Fitted with a vinyl cap at shipment)
(421)

(466)

Unit nameplate
Suction air Safety caution
nameplate Unit nameplate
Wing bolt for fastening during 1-1

(282)
transportation (at 1 location) Safety caution
2

(226)
220

(To be removed before operation) nameplate

(95)
45
45

(93) Suction port: Rc1


30 324 30 3
(149) (Fitted with a vinyl cap at shipment)
384 30 548 30
608

Unit type

Specifications/External Dimension Diagram


DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
85 100 320.5 194.5
T Rc1 150 170 SUT06D4016-30
(Fitted with a vinyl cap at shipment)
37
42

50

4-M8 Part No. Name Quantity


110

(Manifold bracket mount) 1 Oil tank 1


100

2 Suction strainer 1
(309)

T Rc¾
(Plugged at shipment) 3 Stop valve 1
Optional port: Rp⅜
4 Oil level gauge 1
3 5 Oil filler port-cum-air breather 1
Optional port: Rp½ 6-1 Motor pump incorporating an IPM motor 1
6-2 Controller 1
P Rc¾
(Fitted with a vinyl cap at shipment) 7 Oil cooler 1
8 AC fan 1
Foundation plate (Option)
4-φ15 holes (for fixing bolts) (E-SUTPLATE-2)
9 Return filter 1
Pressure indication and operation panel
(M12 bolts recommended) 10 Check valve 1
(40) (620) (40)

9 5
4 1 16
6-2 10 MPa
60 L
Unit nameplate Upper limit
Safety caution (Yellow line)
nameplate
45 L
Lower limit 40
(Red line) L/min
716

Cleaning port tightening caution nameplate 2


648

639

6-1
595

7 Cleaning port
(441)

Suction air

8
20

Bolt
Caution nameplate
95

70

(50)
70

Wing bolt for fastening during 155


40

transportation (at 1 location on the back)


20 10 (To be removed before operation) 30 30 450 Oil sampling port/
25

500 Oil drain port: Rc½


85 530 85 2-M8 (through hole)
700 Tapped holes for mounting
the foundation plate (at 4 locations)

32
Super Unit
[Double pump type]
Maximum
operating
pressure 21 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 60 L/min 110
Model code 100

SUTD6021-30 90
80

Flow rate (L/min)


70
60
50
40
30
20
10
0
Motor pump type
0 5 10 15 20

Pressure (MPa)
Unit type
* The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
6.5 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00D6021-30 SUT06D6021-30 SUT10D6021-30

Maximum flow rate


61.1 (61.1 for combination flow, 21.2 for independent flow)
(theoretical value; L/min) *1
Maximum operating
20.6
pressure (MPa)
Pump unit
Operating flow rate
8.7 to 61.1
adjustment range (L/min)
Operating pressure
1.5 to 20.6
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 5.0 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 22.1
Rated current
AC3 φ200V (60 Hz) 21.7
(A)
AC3 φ220V (60 Hz) 20.2
Power source breaker setting (A) 30
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 58 99 112
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60 100
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
33
External Dimension Diagram

P Rc¾
(Fitted with a vinyl cap at shipment) (140)
Motor pump type

15

(73)
SUT00D6021-30

(294)
384
354

(180)
(95)
Part No. Name Quantity
Motor pump incorporating Pressure indication and operation panel 4-φ10 holes (for fixing bolts)
1-1 1 φ28 hole φ21 hole
15 578
(136)
15 (M8 bolts recommended)

15
an IPM motor (Power cable port) (Signal cable port) 608
1-2 Controller 1 Unloading port Rc½
1-2 (Fitted with a vinyl cap at shipment)
2 AC fan 1
4
3 Base 1 DR Rc⅜
(Fitted with a vinyl cap at shipment)
4 Check valve 1

(466)
Suction Safety caution
Wing bolt for fastening during air Unit nameplate
nameplate 1-1

(282)
transportation (at 1 location) Safety caution

(241)

(226)
(To be removed before operation) 2 nameplate

(95)
(45)

45
30 324 30 (86) Suction port: Rc1
3
384 (142.5) (Fitted with a vinyl cap
608 at shipment)
DR Rp¾ (above oil level)
Unit type T Rc1
(Fitted with a vinyl cap at shipment)
85 100 327 188
(Fitted with a vinyl cap at shipment) 4-M8
150 170
(Manifold bracket mount)
42
110 37

100 50

SUT06D6021-30
(309)

T Rc¾
(Plugged at shipment)
Optional port: Rp⅜ 3
Part No. Name Quantity
Optional port: Rp½
P Rc¾
1 Oil tank 1
(Fitted with a vinyl cap at shipment)
2 Suction strainer 1 4-φ15 holes (for fixing bolts) Foundation plate (Option)
(M12 bolts recommended)
3 Stop valve 1 (E-SUTPLATE-2)
4
4 Oil level gauge 1 9 6-2 5

5 Oil filler port-cum-air breather 1 60 L


10 Unit nameplate
Upper limit (Yellow line)
Motor pump incorporating Safety caution
6-1 1 nameplate
45 L
an IPM motor Lower limit (Red line)

716

Specifications/External Dimension Diagram


6-2 Controller 1 7 Cleaning port
648

6-1
Cleaning port tightening caution nameplate

639
595

7 Oil cooler 1 Suction air


(441)

1
8 AC fan 1 8
2
20

9 Return filter 1
95

155
70
70

(50)
40

10 Check valve 1 20 10 30 30 450 Oil sampling port/


25

Wing bolt for fastening during transportation 85 530 85 2-M8 (through hole) 500 Oil drain port: Rc½
(at 1 location on the back) 700
(To be removed before operation) Tapped holes for mounting
the foundation plate (at 4 locations)
85 100 327 188
DR Rp¾ (above oil level) 4-M8
150 170
SUT10D6021-30 (Fitted with a vinyl cap (Manifold bracket mount)
at shipment)
100 50
167
172

T Rc1
Part No. Name Quantity (Fitted with a vinyl cap
(439)

at shipment)
110

1 Oil tank 1 T Rc¾


(Plugged at shipment)
2 Suction strainer 1 3
Optional port: Rp⅜
3 Stop valve 1 Optional port: Rp½ P Rc¾
4 Oil level gauge 1 (Fitted with a vinyl cap at shipment)

5 Oil filler port-cum-air breather 1


4-φ15 holes (for fixing bolts)
(M12 bolts recommended)
(40) (620) (40)
Foundation plate (Option)
(E-SUTPLATE-2)
21
Motor pump incorporating
MPa
6-1 1 9 6-2
6-2 5 4 Cleaning port
an IPM motor
6-2 Controller 1 100 L
10 Upper limit (Yellow line)
60
Safety caution
7 Oil cooler 1 nameplate
76 L
Lower limit (Red line) L/min
8 AC fan 1
716

7 1
648

639

6-1
595

9 Return filter 1
Suction air 2
(441)

10 Check valve 1 Oil sampling port/


8 Oil drain port: Rc½
20

95

155
70
70

(50)
40

Wing bolt for fastening 20 10 30 30 450 50 80


25

during transportation 85 530 85 580


(at 1 location on the back) 2-M8 (through hole)
700 630
(To be removed before operation) Tapped holes for mounting
the foundation plate
(at 4 locations)

34
Super Unit
[Double pump type]
Maximum
operating
pressure 21 MPa Pressure – Flow rate characteristics (Representative)

Maximum
flow rate 80 L/min 110
Model code 100
90
SUTD8021-30
80

Flow rate (L/min)


70
60
50
40
30
20
10
0
Motor pump type 0 5 10 15 20

Pressure (MPa)

Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
14 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00D8021-30 SUT10D8021-30 SUT16D8021-30

Maximum flow rate


83.0 (83.0 for combination flow, 28.7 for independent flow)
(theoretical value; L/min) *1
Maximum operating
20.6
pressure (MPa)
Pump unit
Operating flow rate
11.6 to 83.0
adjustment range (L/min)
Operating pressure
1.5 to 20.6
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 7.0 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 25.5
Rated current
AC3 φ200V (60 Hz) 24.8
(A)
AC3 φ220V (60 Hz) 22.7
Power source breaker setting (A) 50
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 72 133 145
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 100 160
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
35
External Dimension Diagram

Motor cable Pressure indication and


Motor pump type

15
(139)
operation panel 4
P Rc¾
(Fitted with a vinyl cap at shipment)

SUT00D8021-30 Unloading port: Rc½


(Fitted with a vinyl cap at shipment)

384
354
294
Part No. Name Quantity

(196)
1-1 Motor pump incorporating an IPM motor 1

(125)
1-2 Controller 1
2 AC fan 1
4-φ10 holes (for fixing bolts)
3 Base 1 (97)
(M8 bolts recommended)

15
4 Check valve 1 15 600 15
(60) 630

1-2
DR Rc⅜
(Fitted with a vinyl cap at shipment)
(441)

Unit
483

nameplate

(408)
Suction air (72)
Safety caution

(311)
1-1

(299)
nameplate
2
258

(90)
Transportation nameplate
45

30 324 30 (142)
3 Suction port: Rc1
30 570 30 (Plugged (with O-ring) at shipment)
Wing bolt for fastening during transportation (at 2 locations)
(To be removed before operation)
Unit type
700
85 100 327 188
T Rc1-½ 150 170
SUT10D8021-30
17

(Fitted with a vinyl cap at shipment)


SUT16D8021-30
100 50

Specifications/External Dimension Diagram


150
382 (172)

Part No. Name Quantity


4-M8 1 Oil tank 1
(Manifold bracket mount) 2 Suction strainer 1
(649)(439)

T Rc1-¼
3 Stop valve 1
(Plugged at shipment)
4 Oil level gauge 1
DR Rp¾ (above oil level) 5 Oil filler port-cum-air breather 1
(Fitted with a vinyl cap 6-1 Motor pump incorporating an IPM motor 1
at shipment)
6-2 Controller 1
7 Oil cooler 1
Optional port: Rp⅜ 3
8 AC fan 1
Optional port: Rp½
P Rc¾ 9 Return filter 1
(Fitted with a vinyl cap at shipment) 10 Check valve 1
Foundation plate (Option)
4-φ15 holes (for fixing bolts)
(E-SUTPLATE-2)
(M12 bolts recommended)
(40) (620) (40)
Cleaning port

9 4
5
6-2

21
10
164 L (100 L)
Unit nameplate Upper limit (Yellow line)
Safety caution MPa
nameplate 124 L (76 L)
Lower limit (Red line)
754

7
(647)
671

6-1
Cleaning port tightening caution nameplate
1

80
595

8
2
(441)

L/min
Oil sampling port/
Suction Oil drain port: Rc½
(216)

air
20

95

Wing bolt for fastening


(50)
70

70

155
40

during transportation
(at 1 location on the back) 20 10 30 30 450 50 290 (80)
25

(To be removed before operation) 85 530 85 790 (580)


188.5 700 2-M8 (through hole)
Tapped holes for mounting 840 (630)
(893.5)
the foundation plate
(at 4 locations)
(): Dimensions for SUT10D8021-30

36
Super Unit
[Double pump type]

21 MPa
Maximum
operating Pressure – Flow rate characteristics (Representative)
pressure

Maximum
flow rate 110 L/min 110
Model code 100
90
SUT00D11021-40
P-SUT20D11KW-40 80

Flow rate (L/min)


70
60
50
40
30
20
Motor pump type
10
0
0 5 10 15 20

Pressure (MPa)

Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
16 L/min maximum

Motor pump type Unit type


Specifications Model code SUT00D11021-40 P-SUT20D11KW-40

Maximum flow rate


110 (110 for combination flow, 40.5 for independent flow)
(theoretical value; L/min) *1
Maximum operating
20.6
pressure (MPa)
Pump unit
Operating flow rate
13.3 to 110
adjustment range (L/min)
Operating pressure
1.5 to 20.6
adjustment range (MPa)
Motor capacity
Motor capacity Equivalent to 11 kW
(equivalent kW)
Power supply Motor pump/unit 3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
AC3 φ200V (50 Hz) 38.3
Rated current
AC3 φ200V (60 Hz) 37.8
(A)
AC3 φ220V (60 Hz) 34.9
Power source breaker setting (A) 75
5 channels
External input signal
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 112 360
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 200
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
37
External Dimension Diagram

Motor pump type Grease nipple (A-PT ⅛ type)


Suction port: Rc1 ¼

819

SUT00D11021-40

(Refer to Page 24 for the external dimensions of the controller)

151

134
Motor wiring port (φ28)
AC fan, thermistor wiring port (21)
Drain port
Rc⅜

323

168 496

117 204 42 118

19
Unloading port
Discharge port Rc¾
Rc1−¼

199
Suction
314

air

24: 3
228

207
170

112
4-14.5 (installation)
170

76.5 95.5 132.5


15

108 108
241 228
275

Unit type
1,376
1,088 288 Drain port: Rc¾
(Fitted with plastic plug)
43 1,002 43
P-SUT20D11KW-40

Specifications/External Dimension Diagram


670 250 Tank 2: Rc1
(Fitted with plastic plug)
5
Part No. Name Quantity
1 Oil tank 1
80
90

120

2 Motor pump 1
352

3 Oil level gauge 2


4 Oil filler port-cum-air breather 1
5 Suction strainer 1
(982)

6 Return filter 1
4
7 Oil cooler 1
600

8 Pressure gauge 1
DAIKIN
9 Thermometer 1
10 Outlet block 1
G1/2

11 Vibration-absorbing rubber 6
12 Foundation plate 1
(10)

2 13 Electrical cabinet 1

6 7 13
8 3
10

21
Super Unit switch board
Tank 1: Rc1-½ Discharge port: Rc1
(Fitted with plastic plug) (Fitted with plastic plug)
3
MPa
OIL HYDRAULIC UNIT

Unit nameplate 200 L


Upper limit: 200 L
850

Safety caution
nameplate

Lower limit: 165 L


110
Leak test by fil ing water
Certificate nameplate

Oil level
1,150

gauge guard
Suction
Thermometer
L/min
942

920

air 1
866

■■■■■■■■■■■■■■
■■■■■■■■■■■■■■

■■■■■■■■■■■■
■■■■■■■■■■■■
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

DAIKIN

9
300

210
210

Wiring port for the user 155


11
12 4-φ15 holes 237 Tank drain port: Rc½ (at 3 locations) 544

( )
The base plates (4 pcs.) provided as accessories 838
can be mounted at the desired positions. (Fitted with high-pressure plug)
(Accessories, supplied with 8 bolts)
Secure the unit before using it.

38
Operation Panel

Part names, functions, and the operation

Using the key switches on the Super Unit controller, you can monitor the pressure and flow rate and set or
change parameters.
 Outline of Functions
NO. Item Description

[MODE] key Selects the operation mode.

Decrements a value set for the operation


[DOWN] key
mode/monitor mode/data.

Increments a value set for the operation


[UP] key
mode/monitor mode/data.

Confirms the edited operation mode/monitor


[ENT] key
mode/data.

Normal mode: Displays the actual pressure or


alarm code.
Monitor mode: Displays the pressure switch
setting, each pressure setting,
each flow rate setting, the
actual flow rate, or the actual
rotation speed.
Data display
Setting mode: Set or change the pressure,
flow rate, or other parameters.
Alarm mode: Check the alarm history.
Communication setting mode:
Change communication
settings.

 Mode selection
To go to the monitor mode or return to the normal mode from other modes, press the key.
To go to other modes, press and hold down a combination of relevant keys for 2 seconds.

Turn on the power

Normal mode

Hold down for more Hold down for more Hold down for more
than two seconds. than two seconds. than two seconds.

Monitor mode Setting mode Alarm mode Communication


setting mode
* Enabled only when equipped
with function option C
(communication function)

39
Monitor mode

The following items can be checked in the monitor mode.


Item No. Name Unit Description
MPa [When the PSI unit is selected: ×10 PSI]
n00 *1 Pressure switch setting Displays the pressure switch setting.
×10PSI

MPa [When the PSI unit is selected: ×10 PSI]


n01 *1 Pressure setting Alternately displays the high (single flow) and low (combination flow)
×10PSI pressure settings for the current P-Q selection number.

Alternately displays the high (single flow) and low (combination flow) flow
n02 Flow rate setting L/min
rate settings for the current P-Q selection number.

n03 Flow rate L/min Displays the current flow rate (theoretical value).

Displays the alarm code of the alarm that occurred most recently.

n04 *2 Latest alarm code The current power ON count can be checked by pressing the key.
Press the key to check how many times the power has been turned on so far.

n05 Motor rotation speed ×10min−1 Displays the current rotation speed of the motor.

[SUTD]
Displays the solenoid valve switching status: “Low pressure [L]” (combination
flow) or “High pressure [H]”(single flow), and the P-Q selection number.

Example: Combination flow (low pressure) - P-Q selection No. 1

n06 Operation status — [SUTS]


Displays the low pressure status [L] and P-Q selection number or the
selected P-Q selection number only.

Example: Combination flow (low pressure) - P-Q selection No. 1

Example: P-Q selection No. 2

Displays the total number of rotations of the motor when it rotates in the
min−1 reverse direction due to reverse flow from the load when the power supply
n07 Reverse rotations at power OFF for the unit is turned OFF.
This value is used to estimate the machine load volume.

% Displays the regenerative load integration ratio of the current regenerative


n08 Regenerative load integration ratio
braking resistance.

n10 Motor temperature °C Displays the temperature of the motor.

n11 Heat emission fin temperature °C Displays the temperature of the heat emission fins of the controller.

Operation Panel
Displays the controller’s internal circuit voltage.
The indicated voltage is a value equivalent to "power supply voltage 2".
n12 Main circuit DC voltage V The main circuit voltage may vary depending on the operating conditions
and momentarily exceed 350 V due to a regenerative current during
deceleration and other operations. However, this is not abnormal.

n13 *3 Pressure command Displays the input voltage at analog input terminal AIN1.

n14 *3 Flow rate command Displays the input voltage at analog input terminal AIN2.

n15 *3 Actual pressure Displays the output voltage at analog output terminal AO1.

n16 *3 Actual flow rate Displays the output voltage at analog output terminal AO2.

*1: The default setting is displayed in MPa (standard display unit). If you change the display unit to PSI, ensure that you indicate in some manner that the monitor value
is displayed using the PSI unit (attach a label, etc). However, use of the PSI unit in Japan is subject to punishment under the Measurement Law. Users should
supply their own unit indication labels.
*2: You can check the current power ON count by pressing the key when an alarm code is displayed. For details on alarm codes, refer to the alarm descriptions in the Operation Manual.
*3: Enabled only when equipped with function option P (analog input function)

Setting mode
The following data can be set in the setting mode.
For details on the settings, refer to the Operation Manual of the relevant model since they vary depending on the model.
 The pressure, flow rate, acceleration time, deceleration time,  Dry run judging pressure, time, etc.
etc., to be set for multi-stage pressure/flow rate control
 Various control gains
 Enable/disable setting of pressure switch functions
 Display unit selection

40
Electric Wiring

Power supply and I/O signal cables

SUTS1507-30, SUTS3007-30, SUTS1510-30


SUTS4007-30, SUTS6007-30, SUTS3010-30
SUTS1516-30, SUTS3016-30
SUTD4016-30, SUTD6021-30
Internal terminal layout (with the controller cover open)
Ground terminal I/O signal terminal block

Recommended cable clamp


OA-W1611
(I/O signal cables)

Recommended cable clamp


OA-W2216 (power cables)

Power supply connection terminal block

SUTS8007-30, SUTD8021-30
Internal terminal layout (with the controller cover open)

I/O signal terminal block

Power supply connection


terminal block
Ground terminal
for power cable

Recommended cable clamp Recommended cable clamp


OA-W2216 (power cables) OA-W1611 (I/O signal cables)

* Main power supply connections: Connect a 3-phase AC power supply (200 V/50 Hz, 200 V/60 Hz, or 220 V/60 Hz) to the power supply terminals
(L1, L2 and L3), and connect a ground cable to the ground terminal.
* I/O signal connections: Connect digital input terminals, digital output terminals, and contact output terminals as shown on Page 42.

41
SUT00S11007-40, SUT00D11021-40, P-SUT20D11KW-40

User I/O terminal block (M3)


 Encoder
 Motor thermistor
FG
FG
GND
+5V

 Pressure sensor
Z-
Z+ 危 険
B- WARNING
B+

 I/O signal
A-
A+
THM- May cause
THM+ electric shock.
AGND
AO2 before opening terminal
(QO) AGND cover of unit.
AO1 Wait 5 minutes until
DC Bus capacitors
(PO) dischange.

DAIKIN INDUSTRIES,LTD.
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6 A PF
DO5
DO4
DO3

DO2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG

Main power supply terminal


FG

block (M5)
 Main power supply
 DC reactor Solenoid valve terminal block (M4)
 Regenerative resistor  Solenoid valve power supply
 Motor output  AC fan power supply

Digital input signal Digital output signal

External power supply


External control equipment (DC 24 V)
ICOM 4.7 kΩ
External power supply
(DC 24 V) DO1
DIN1 2.2 kΩ
Load
50 mA maximum
4.7 kΩ

DO2
DIN2 2.2 kΩ
Load

4.7 kΩ OCOM

DIN3 2.2 kΩ

* The digital output common terminal can be either positive or negative.


4.7 kΩ
* Prepare an external power supply (DC 24 V ± 1 V, 0.5 A or more).

Electric Wiring
* The maximum output current of the output circuit is 50 mA per channel.
DIN4 2.2 kΩ

Contact output signal * The switching capacity of the


4.7 kΩ contact output is DC 30 V,
0.5 A (at resistance load).
DIN5 2.2 kΩ
COM Contact output a * The minimum applicable load of
5 mA the contact output is DC 10 mV,
Contact output b 10 µA, but this is only a guide to
the lower limit where switching
Common is possible with a minute load.
The value varies depending on the
* The digital input common terminal can be either positive or negative.
(The above figure shows the normal switching frequency, environmental
* Prepare an external power supply (DC 24 V ± 1 V, 0.5 A or more).
status of the relay contacts.) conditions, etc., so it is advisable
* The current of the input circuit is 5 mA per channel.
to check the actual value.

 Enabled when equipped with function option P (analog input function)


Analog input signal Analog output signal

AIN1 AO1
Pressure command input Pressure monitor output
AGND AGND V
0 to 10 V −10 to 10 V

AIN2 AO2
Flow rate command input Flow rate monitor output
AGND AGND V
0 to 10 V −10 to 10 V

42
Harness specifications(to be prepared by the customer)
The harnesses that need to be prepared by the customer are as follows.
Power supply cable I/O signal cable
Model code Recommended Recommended Recommended Recommended
Cable size Recommended cable crimp terminal cable clamp Cable size cable cable clamp
SUTS1507
SUTS3007 OA-W2213
SUTS1510 2.5 mm2 or more
CE362 2.5 mm2 × 4 wires (OHM ELECTRIC)
(AWG14 or RBV2-4
SUTS3010 (KURAMO ELECTRIC) Applicable cable outer
larger size)
SUTS1516 diameter: φ9 to φ13 0.3 to 0.5 mm2
SUTS3016 (AWG20 to 22)
OA-W2216
4.0 mm2 or more
CE362 4.0 mm2 × 4 wires (OHM ELECTRIC)
SUTS6007 (AWG12 or RBV5.5-4
(KURAMO ELECTRIC) Applicable cable outer
larger size)
diameter: φ13 to φ16

OA-W2219
6.0 mm2 or more OA-W1611
CE362 6.0 mm2 × 4 wires (OHM ELECTRIC) 0.3 to 1.0 mm2
SUTS8007 (AWG10 or RBV5.5-5 (OHM ELECTRIC)
(KURAMO ELECTRIC) Applicable cable outer (AWG16 to 22)
larger size) Applicable cable
diameter: φ15 to φ19
KVC-36SB outer diameter:
0.3 - 0.5 mm2 φ9 to φ11
OA-W2216
2.5 mm or more
2
CE362 2.5 mm2 × 4 wires (OHM ELECTRIC)
SUTD4016 (AWG14 or (KURAMO ELECTRIC) RBV2-4 Applicable cable outer
larger size) diameter: φ13 to φ16
0.3 to 0.5 mm2
OA-W2216 (AWG20 to 22)
4.0 mm or more
2
CE362 4.0 mm2 × 4 wires (OHM ELECTRIC)
SUTD6021 (AWG12 or
Applicable cable outer
(KURAMO ELECTRIC)
larger size)
diameter: φ13 to φ16
RBV5.5-5
OA-W2219
6.0 mm or more
2
CE362 6.0 mm2 × 4 wires (OHM ELECTRIC) 0.3 to 1.0 mm2
SUTD8021 (AWG10 or (KURAMO ELECTRIC) Applicable cable outer (AWG16 to 22)
larger size) diameter: φ15 to φ19
SUT00S11007 CE362 10.0 mm2 × 4 wires 0.3 to 0.5 mm2
10 mm2 or more R8-5 - -
SUT00D11021 (KURAMO ELECTRIC) (AWG20 to 22)

Power supply cable for solenoid valve output


Model code
Recommended cable Recommended crimp terminal
SUT00S11007 CE362 0.5 mm2 × 3 wires (Controller side) RBA1.25-4
SUT00D11021 (KURAMO ELECTRIC) (Solenoid valve side) RBA1.25-3

Motor cable AC fan power supply cable Motor thermistor harness


Model code Recommended Recommended Recommended
Recommended cable Recommended cable Recommended cable
crimp terminal crimp terminal crimp terminal
(Controller side) (Controller side)
SUT00S11007 CE362 10 mm2 × 4 wires R8-5 CE362 0.5 mm2 × 3 wires (Controller side) KVC-36SB 0.3 to 0.5 mm2 RBA1.25-3
SUT00D11021 (KURAMO ELECTRIC) (Motor side) (KURAMO ELECTRIC) RBA1.25-3 (KURAMO ELECTRIC) (Motor side)
R8-6 RBA1.25-3.5

Harness specifications (options for SUT00S11007/SUT00D11021)


The encoder harness and pressure sensor harness for SUT00S11007/SUT00D11021 are options and can be ordered
separately.
If preparing your own harnesses, make the harness length no greater than 5 m.

Terminal specifications Cable specifications Ferrite core/


Super
Name Model code Ring core
Unit Design No. Cable
SUT unit Controller side Cable type Cable gauge length (recommended)

Contact 170366-1 Round terminal with a KVC-36SB


Encoder Housing 172169-1 vinyl insulation sheath (KURAMO AWG22
5m Not required
10, 20, 30, 40 PM-SEH05-P22-A09R (0.3 mm2)
harness (PBA1.25-3) ELECTRIC)
(All manufactured by AMP)
(Manufactured by JST)
Ferrite core
TFCM-16-8-16
PM-SPH05
10, 20 Contact 171630-1 (Kitagawa
(with a ferrite core) Round terminal with a KVC-36SB
Pressure Rubber cap 172746-1 Industries)
vinyl insulation sheath AWG20
sensor Housing 174357-2 (KURAMO 5m or equivalent
(PBA1.25-3) (0.5 mm2)
harness Double lock plate 1-174358-1 ELECTRIC)
Ring core
PM-SPH05-003 Equivalant to
30
(with a ring core) (All manufactured by AMP) (Manufactured by JST) R-47/27/15(A)
MA055 (JFE)

43
Options (Separately available parts)

Unit accessory
The following optional parts can be purchased separately from the Super Unit.
These parts are to be mounted by the user.

 Base plate set


These parts are used to fasten the Super Unit to a floor surface.
The bolts for mounting the unit to the floor should be prepared by the user.
Applicable model
Model code Color Accessories
Unit type: Single pump type Unit type: Double pump type
SUT03S1507-30
SUT03S3007-30
SUT06D4016-30 (1) Base plate (4 pcs)
SUT06S6007-30
SUT10S8007-30 SUT06D6021-30 Ivory white (2) Tank fastening bolt (8 pcs)
E-SUTPLATE-2 SUT03S1510-30 SUT10D6021-30 (Munsell code
SUT03S3010-30 SUT10D8021-30 5Y7.5/1) (3) Plain and spring washers for
SUT03S1516-30 SUT16D8021-30
the above parts (8 pcs each)
SUT03S4007-30
SUT06S3016-30

Example of installation

25 25
 Base plate
2-C3
dimensions

25
φ15 hole

10 30 10

2-C3 2-φ10 holes


t3.2

40

25
40 50:

 Level switch
Operating Operating Contact Protection
Model code Oil level triggering alarms CE standard
voltage current resistance class
SUT03 (with 30 L tank) 21 L maximum Closed
SUT06 (with 60 L tank) 50 L maximum Closed
E-DLSN-130L-A-10 SUT10 (with 100 L tank) 83 L maximum Closed
SUT16 (with 160 L tank) 135 L maximum Closed
SUT03 (with 30 L tank) 21 L maximum Open
SUT06 (with 60 L tank) 50 L maximum Open
E-DLSN-130L-B-10 SUT10 (with 100 L tank) 83 L maximum Open
AC 100/110 V 0.02 A
1 Ω maximum IP65 SUT16 (with 160 L tank) 135 L maximum Open N/A
Electric Wiring
Options (Separately available parts)

DC 24 V 0.05 A
SUT06 (with 60 L tank) 45 L maximum Closed
E-DLSN-170L-A-10 SUT10 (with 100 L tank) 75 L maximum Closed
SUT16 (with 160 L tank) 123 L maximum Closed
SUT06 (with 60 L tank) 45 L maximum Open
E-DLSN-170L-B-10 SUT10 (with 100 L tank) 75 L maximum Open
SUT16 (with 160 L tank) 123 L maximum Open

* Directly mountable on the Rc1/2 option port on the top face of each tank.

 Temperature switch
Operating Operating Contact Protection
Model code Oil level triggering alarms CE standard
voltage current resistance class

AC 100 V 2A
E-MQT83PD-L60X1-10 30 mΩ maximum IP65 60°C N/A
DC 24 V 50 mA

* Directly mountable on the Rc3/8 option port on the top face of each tank.

 Thermometer  Micro separator


Model code Thermometer specification Temperature indication range Size Model code Size

E-RBT-100-200L Bimetal type 0 to 100°C φ45 E-MSB-110 110 × 60 × 30

44
Bracket/Piping Set for Manifolds

In order to install a control system on the Super Unit, select a bracket and piping set for the manifold according to the
control system’s size and number of series. Please prepare a manifold block separately.

Super Unit Installation of 02 Size Control Systems


Manifold bracket Piping set
Model code Tank capacity Return filter
Model code Model code Part Configuration
SUT03S1507-30 E-SUT03S1507N-PIPE-02
SUT03S1510-30 E-SUT03BASE-402 (Maximum installable series : 4) E-SUT03S1510N-PIPE-02
SUT03S1516-30 [Mountable manifold blocks] E-SUT03S1516N-PIPE-02
30 L Not provided BT-102-50 (1 series) to BT-402-50 (4 series) ①
SUT03S3007-30 or E-SUT03S3007N-PIPE-02
SUT03S3010-30 BT-102-50-140 (1 series) to BT-402-50-140 (4 series) E-SUT03S3010N-PIPE-02
SUT03S4007-30 E-SUT03S4007N-PIPE-02
SUT06S3016-30 E-SUT06BASE-302 (Maximum installable series : 3) E-SUT06S3016F-PIPE-02 ②
SUT06S6007-30 [Mountable manifold blocks] E-SUT06S6007F-PIPE-02
60 L BT-102-50 (1 series) to BT-302-50 (3 series)
SUT06D4016-30 E-SUT06D4016F-PIPE-02
or
SUT06D6021-30 BT-102-50-140 (1 series) to BT-302-50-140 (3 series) E-SUT06D6021F-PIPE-02
Provided
SUT10D6021-30 E-SUT06BASE-602 (Maximum installable series : 6) E-SUT10D6021F-PIPE-02 ③
[Mountable manifold blocks]
SUT10S8007-30 100 L E-SUT10S8007F-PIPE-02
BT-102-50 (1 series) to BT-602-50 (6 series)
SUT10D8021-30 or E-SUT10D8021F-PIPE-02
SUT16D8021-30 160 L BT-102-50-140 (1 series) to BT-602-50-140 (6 series) E-SUT16D8021F-PIPE-02

Super Unit Installation of 03 Size Control Systems


Manifold bracket Piping set
Model code Tank capacity Return filter
Model code Model code Part Configuration
SUT03S1507-30 E-SUT03S1507N-PIPE-03
SUT03S1510-30 E-SUT03S1510N-PIPE-03
SUT03S1516-30 E-SUT03BASE-203 (Maximum installable series : 2) E-SUT03S1516N-PIPE-03
30 L Not provided [Mountable manifold blocks] ①
SUT03S3007-30 BT-103-40 (1 series), BT-203-40 (2 series) E-SUT03S3007N-PIPE-03
SUT03S3010-30 E-SUT03S3010N-PIPE-03
SUT03S4007-30 E-SUT03S4007N-PIPE-03
SUT06S3016-30 E-SUT06S3016F-PIPE-03 ②
SUT06S6007-30 E-SUT06BASE-203 (Maximum installable series : 2) E-SUT06S6007F-PIPE-03 ③
60 L
SUT06D4016-30 [Mountable manifold blocks] E-SUT06D4016F-PIPE-03
BT-103-40 (1 series), BT-203-40 (2 series) ④
SUT06D6021-30 E-SUT06D6021F-PIPE-03
Provided
SUT10D6021-30 E-SUT06BASE-403 (Maximum installable series : 4) E-SUT10D6021F-PIPE-03
SUT10S8007-30 100 L [Mountable manifold blocks] E-SUT10S8007F-PIPE-03
BT-103-40 (1 series), BT-403-40 (4 series) ③
SUT10D8021-30 E-SUT10D8021F-PIPE-03
SUT16D8021-30 160 L E-SUT16D8021F-PIPE-03

Component parts
 Manifold bracket
Model code Maximum installable series Accessories
E-SUT03BASE-402 4-series Hexagon socket head cap
E-SUT06BASE-302 3-series bolt for mounting manifold
• Bracket body 1 pc. (M8 × 85) 2 pcs.
E-SUT06BASE-602 6-series
• Hexagon bolt (M8 × 16) 4 pcs.
E-SUT03BASE-203 2-series • Flat washer (M8) 4 pcs. Hexagon socket head cap
E-SUT06BASE-203 2-series bolt for mounting manifold
E-SUT06BASE-403 (M8 × 105) 4 pcs.
4-series

45 IN V E RT ER H Y D R A U LIC U N IT
 Piping set

Part Configuration 1
7
6 5
1
8

* The external shape differs depending on the model.

• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 54.0 to 66.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 43.0 to 47.5
E-SUT03S1507N-PIPE-02 3 Hose adaptor (elbow) 1 43.0 to 47.5 E-SUT03S1507N-PIPE-03 3 Hose adaptor (elbow) 1 64.0 to 70.0
E-SUT03S1510N-PIPE-02 4 ― ― ― E-SUT03S1510N-PIPE-03 4 Bushing 1 110.0 to 120.0
E-SUT03S1516N-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT03S1516N-PIPE-03 5 Steel pipe 1 247.0 to 286.0
E-SUT03S3007N-PIPE-02 6 Steel piping joint (straight) 1 28.5 to 33.0 E-SUT03S3007N-PIPE-03 6 Steel piping joint (straight) 1 95.0 to 110.0
E-SUT03S3010N-PIPE-02 7 Steel piping joint (elbow) 1 28.5 to 33.0 E-SUT03S3010N-PIPE-03 7 Steel piping joint (elbow) 1 57.0 to 66.0
8 Bushing 1 95.0 to 110.0 8 ― ― ―
9 Installation guide 1 ― 9 Installation guide 1 ―
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 64.0 to 70.0 2 Hose adaptor (straight) 1 64.0 to 70.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
4 ― ― ― 4 ― ― ―
E-SUT03S4007N-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT03S4007N-PIPE-03 5 Steel pipe 1 247.0 to 286.0
6 Steel piping joint (straight) 1 28.5 to 33.0 6 Steel piping joint (straight) 1 95.0 to 110.0
7 Steel piping joint (elbow) 1 28.5 to 33.0 7 Steel piping joint (elbow) 1 57.0 to 66.0
8 Bushing 1 95.0 to 110.0 8 ― ― ―
9 Installation guide 1 ― 9 Installation guide 1 ―

Part Configuration 2 5 8 Mounted in the port at the back of the return filter

6 1
6
3 4
(Separately available parts)
Options

* The external shape differs depending on the model.

• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 54.0 to 66.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 43.0 to 47.5
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 64.0 to 70.0
4 ― ― ― 4 Bushing 1 110.0 to 120.0
E-SUT06S3016F-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT06S3016F-PIPE-03 5 Steel pipe 1 247.0 to 286.0
6 Steel piping joint (elbow) 2 28.5 to 33.0 6 Steel piping joint (elbow) 2 95.0 to 110.0
7 Bushing 1 57.0 to 66.0 7 ― ― ―
8 Plug 1 95.0 to 110.0 8 Plug 1 95.0 to 110.0
9 Installation guide 1 ― 9 Installation guide 1 ―

IN VERT ER H Y D R A U L I C U N I T 46
● Piping set
9
Part Configuration 3 5
Mounted in the port at the back of the return filter

6 1
6
3

7 8

* The external shape differs depending on the model.

• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 64.0 to 70.0 2 Hose adaptor (straight) 1 110.0 to 120.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
E-SUT06S6007F-PIPE-02 4 High-pressure bushing 1 110.0 to 120.0 4 ― ― ―
E-SUT06D4016F-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT06S6007F-PIPE-03 5 Steel pipe 1 247.0 to 286.0
E-SUT06D6021F-PIPE-02 6 Steel piping joint (elbow) 2 28.5 to 33.0 E-SUT10D6021F-PIPE-03 6 Steel piping joint (elbow) 2 57.0 to 66.0
E-SUT10D6021F-PIPE-02 7 Low-pressure bushing 1 57.0 to 66.0 7 ― ― ―
8 ― ― ― 8 ― ― ―
9 Plug 1 95.0 to 110.0 9 Plug 1 95.0 to 110.0
10 Installation guide 1 ― 10 Installation guide 1 ―
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 110.0 to 120.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
4 High-pressure bushing 1 110.0 to 120.0 4 ― ― ―
E-SUT10S8007F-PIPE-02 E-SUT10S8007F-PIPE-03
5 Steel pipe 1 100.0 to 120.0 5 Steel pipe 1 247.0 to 286.0
E-SUT10D8021F-PIPE-02 E-SUT10D8021F-PIPE-03
E-SUT16D8021F-PIPE-02 6 Steel piping joint (elbow) 2 28.5 to 33.0 E-SUT16D8021F-PIPE-03 6 Steel piping joint (elbow) 2 57.0 to 66.0
7 Low-pressure bushing (small) 1 57.0 to 66.0 7 Bushing 1 114.0 to 132.0
8 Low-pressure bushing (large) 1 114.0 to 132.0 8 ― ― ―
9 Plug 1 142.5 to 165.0 9 Plug 1 142.5 to 165.0
10 Installation guide 1 ― 10 Installation guide 1 ―

Part Configuration 44 4
6 Mounted in the port at the back of the return filter

5
5
1

* The external shape differs depending on the model.

• For installing 03 size control systems


Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (elbow) 2 110.0 to 120.0
3 Female-male elbow 1 110.0 to 120.0
E-SUT06D4016F-PIPE-03
4 Steel pipe 1 247.0 to 286.0
E-SUT06D6021F-PIPE-03
5 Steel piping joint (elbow) 2 57.0 to 66.0
6 Plug 1 95.0 to 110.0
7 Installation guide 1 ―

47 IN V E RT ER H Y D R A U LIC U N IT
(Separately available parts)
Options

IN VERT ER H Y D R A U L I C U N I T 48
Method of Selection

How to Select a Super Unit

 How to Select a SUPER UNIT


1. Determine the cylinder that requires the maximum pressure and flow rate.
2. To operate several cylinders simultaneously, calculate the pump discharge rate required for each circuit. Refer to (6) below.

(1) Calculation of cylinder output (see the calculation formula for each load) F: Load (N)
Calculate the force F (N) required for the cylinder. A: Pressurized area of the
(2) Calculation of the required pressure (Pu) of the cylinder (Pu = F/A) cylinder (cm2)
* The pressurized area varies
Based on the force (F) and pressurized area (A), calculate the net pressure (Pu; MPa) depending on the specifications of
required for the cylinder. the hydraulic cylinder.

(3) Calculation of the required pressure (Pp) of the pump (Pp = Pu + P)


P: Valve pressure loss +
Calculate the pressure Pp (MPa) required for the pump by adding the total pressure
Piping pressure loss (MPa)
loss P to the pressure (Pu) required for the cylinder.

(4) Calculation of the net required discharge rate (Qc) of the cylinder (Qc = A × V × 0.06) V: Speed (cm/sec)
Based on the cylinder speed (V) and pressurized area (A), calculate the net discharge
rate (Qc; L/min) of the cylinder.
g1: Flow rate loss (L/min)
(5) Calculation of the required discharge rate (Qp) of the pump
Set the flow rate loss according
Add the flow rate loss to the net discharge rate (Qc) of the cylinder.
to (1) the pressure reducing
(6) Total required discharge rate (Qp) of the pump valve type, and (2) the pressure
Calculate the maximum required discharge rate of the pump by totaling the (Qp) values reducing valve diameter.
of the cylinders to be simultaneously operated.

3. Based on the maximum required pump pressure (Pp) and pump discharge rate (Qp), select the Super Unit size.
By referring to the "Pressure – Flow Rate Characteristics" charts (on Pages 13 and 14), select a model such that the Pp and
Qp values of all cylinders fall within the P-Q curve.

(Reference) Load analysis (cylinder output)


Calculate the cylinder force (Fs) depending on the operation and load type.

Operation/Load type Calculation of force (Fs)

Load requiring a pushing or


User-defined value
A. Mechanical pulling force
load (Examples: pressing, forming, (Generally specified in tons)
cutting, shearing)

W Load driven by negative force


B. Load driven
under its own
in a cylinder pushing or pulling Fs = W The required force is equal
operation to move a driven
weight target (e.g., table lifter)
to the weight of the driven target.
load up/down.

Fs = I1/I2 × W W
Load whose direction of force L1
C. Inverting load changes (+ → −) I2
θ
(Examples: down ender, I1 = L1 × cosθ θ
L2 I1
workpiece rotation) I2 = L2 × cosθ

Fs = W × µ
Load driven by positive sliding
Friction coefficient
D. Resistance force in both forward and

{
W
W
load backward operation Standard setting: 0.3
(Examples: pusher, table slide)
Other cases: user-defined value

Fs = W × µ
Load driven by large inertial
Friction coefficient
force in high-speed operation
E. Inertial load W
W
with a heavy object
(Example: Coil car travel) { Standard setting: 0.1
Other cases: user-defined value

49
Handling

The following are the minimum requirements for use of the Super Unit.
For details, refer to the unit’s Instruction Manual.

 Ambient conditions
1. Ambient temperature: 0 to 40°C, ambient humidity: 85%RH maximum (with no condensation), altitude:
1,000 m maximum, to be used indoors

 Hydraulic oil
1. Use general petroleum hydraulic oil (R&O) or wear-resistant hydraulic oil.
If use of hydrous or synthetic oil is intended, consult Daikin.
2. Use hydraulic oil equivalent to ISO VG32 to 68 and operate the unit within an oil viscosity range from 15 to 400 mm2/s
and a tank oil temperature from 0 to 60°C. The recommended operating range is from 15 to 50°C (20 to 200 mm2/s).
3. Keep contamination of hydraulic oil within NAS class 9, or NAS class 10 for 7 MPa or lower pressure.

 Installation and piping


1. This hydraulic unit mounts the motor pump using vibration-absorbing rubber to prevent pump vibration being
transmitted to the unit. Use hoses for piping to the unit to provide flexibility.
2. The unit is a stationary type. Fix it with bolts on a level location that is free of vibration.

3. Keep obstacles that will obstruct air intake and emission at least 100 mm away from the end face of the unit.
Install the unit at a location with good air flow so that heated air can be vented.
4. Use hoses for piping to provide flexibility.
5. Before operating the unit, be sure to remove the wing bolt and spacer for protecting the rubber vibration isolator.
If you fail to do so, the noise and vibration may be excessive.
6. Be sure to secure the space required to access the unit during electrical wiring at the noise filter box or control unit side.

 Electric wiring
1. Install a no-fuse breaker and a ground fault interrupter compliant with European Standard EN60947-2 in the main
power supply of this hydraulic unit, to protect the electrical circuits against shorting and overcurrent, and to prevent
electric shocks.
2. Use suitable electric cable in accordance with the power supply capacity.
3. Be sure to provide a ground connection with a grounding resistance of 100 Ω maximum, and connect the grounding
wire directly with no breaker in the line.
4. Take care not to leave waste metal such as screws and cutting chips, combustible matter such as wood waste or oil,
or wiring debris inside the controller.
5. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit.
6. Before accessing the interior of the controller, turn the unit’s power supply OFF. Make sure that the circuit is turned
OFF using the circuit breaker for the primary power supply, and then wait at least 5 minutes.

 Other precautions
1. If a failure occurs in the hydraulic unit, the system indicates an alarm and stops.
2. If failure or malfunction of this unit is expected to cause death or pose a danger to human beings, adopt appropriate
safety measures in the facilities. If this unit is used in an important facility, also adopt appropriate safety measures in
the facility to ensure that a failure of the equipment will not lead to a serious accident or loss.
Method of Selection
Handling

3. It takes approximately 3 seconds for this hydraulic unit to start up after being powered ON.
Depending on the piping conditions, the unit may take longer to increase the pressure to the pressure switch’s
preset level, resulting in pressure switch signal output. In this case, set the machine up so that it will not accept this
alarm output during this period.

4. Do not turn the power OFF/ON with the main power breaker frequently. It may damage controller components.
(Use the “run/stop” digital input signals for frequent power OFF/ON control.)

50
[Official] Introducing a Video Site
We have opened a site where you can watch videos on the latest
models of the DAIKIN Oil Hydraulics Division, including Super Unit,
EcoRich, and oil cooling units, all in one place.
Everything from the energy-saving technology supporting hybrid
products to the features and functions of each model is explained in The site is also ready
an easy-to-understand manner. for smartphones and
By registering the page in the favorites on your computer or cell tablets!
phone, you can find the latest information at your fingertips any time.
Daikin Hydraulic Search
URL https://www.daikinpmc.com/en/mv/index.html

Osaka Office
YODOGAWA PLANT
1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan
Phone: 81-6-6349-4475
Fax.: 81-6-6349-7862
Home Page: https://www.daikinpmc.com/en/

Contents in this catalog are subject to change for improvement without prior notice.

GK244C (2019.04.010) DF.MD.MD

You might also like