DTS Ks-Sil2 01-2019 Eng
DTS Ks-Sil2 01-2019 Eng
List of Hybrid
Hydraulic Unit P.3 to 4
Models
INVERTER HYDRAULIC UNIT List of Super Unit
Models P.5
Nomenclature
Features P.7 to 8
Functions P.9
Pressure – Flow
Rate Characteristics P.13 to 14
(Typical)
Specifications/External
Dimension Diagram P.15 to 24
7 MPa
Specifications/External
Dimension Diagram P.25 to 28
10 MPa
Specifications/External
Dimension Diagram P.29 to 32
16 MPa
Specifications/External
Dimension Diagram P.33 to 38
21 MPa
Options
P44. to 48
(Separately available parts)
Handling P.50
01
Combining Daikin’s original high-efficiency IPM motors
and hydraulic technology enables an Movie of IPM
unparalleled energy-saving effect and motor for easy
understanding
advanced functions. URL https://www.daikinpmc.com/en/mv/ipm_motor.html
02
Specifications vary depending on the machine
The Daikin product lineup provides various
110 SUT00S11007 16
L/min PQ
Equivalent to Hyb.
11.0 kW Win
See Pages 23 to 24
80 SUT00S8007 16 Hyb.
L/min PQ Win
SUT10S8007
Equivalent to
7.0 kW
See Pages 21 to 22
60 SUT00S6007 16 Hyb.
PQ Win
L/min
SUT06S6007
Equivalent to
5.0 kW
See Pages 19 to 20
40 SUT00S4007 16 Hyb.
PQ Win
L/min
SUT03S4007
Equivalent to
3.7 kW
See Pages 17 to 18
25 EHU2504 EHU2507
16 Equivalent
Equivalent Equivalent Equivalent to Equivalent to
L/min PQ to 2.8 kW
to 1.5 kW to 2.2 kW 2.8 kW 3.7 kW
Hyb.
Hyb.
Win
Win See Pages 15 to 16 See Pages 27 to 28
16 Equivalent
Equivalent to Equivalent to
PQ to 2.2 kW
2.2 kW 2.8 kW
Hyb. Hyb. Hyb.
Win Win Win See Pages 15 to 16 See Pages 25 to 26
Maximum
operating
pressure
4 MPa 7 MPa 7 MPa 7 MPa 10 MPa
16-pattern Communication Analog command Hyb. Hybrid-Win compatible
PQ control function input
Win * Refer to Page 9.
03
type.
functions and capacities according to the machine type.
300 SUT00D30028
SUT00D11021 16
Equivalent to
11.0 kW SUT00D22028
220 Hyb.
See Pages 37 to 38 L/min Win
Equivalent to
SUT00D8021 16 Hyb. 37.0 kW
PQ Win
SUT10D8021
SUT16D8021
SUT00S20018 SUT00D20021 S-SUT00D20025
200 Hyb. S-SUT00D20021 Hyb.
Equivalent to L/min Win Win
Hyb.
7.0 kW Equivalent to Win Equivalent to
See Pages 35 to 36 22.0 kW Equivalent to 22.0 kW
15.0 kW
SUT00D6021 16 Hyb.
PQ Win
Equivalent to
15.0 kW 15.0 kW
5.0 kW
See Pages 33 to 34
Equivalent to
3.7 kW
See Pages 31 to 32
80 SUT00S8018 SUT00D8021 S-SUT00D8025
L/min Hyb. Hyb. Hyb.
Win Win Win
Equivalent to Equivalent to Equivalent to
SUT00S3016 16 Hyb. 11.0 kW 11.0 kW 11.0 kW
PQ Win
SUT06S3016
50 SUT00S5021 SUT00S5025
Hyb.
Hyb.
Equivalent to L/min Win Win
SUT00S1516 16 Hyb.
PQ Win
30 SUT00S3018 SUT00D3021
SUT03S1516 L/min
Hyb. Hyb.
Win Win
Equivalent to Equivalent to
7.0 kW 7.0 kW
Equivalent to
3.7 kW
See Pages 29 to 30
Maximum
16 MPa 21 MPa operating
pressure
18 MPa 21 MPa 25 MPa 28 MPa
*1: The above motor capacities are given for guidance only and do not represent the standard capacities of general motors.
*2: When selecting a Super Unit, verify the specifications of each model by referring to “Pressure – Flow rate Characteristics (Typical)” on Pages 13 and 14 and “How to Select a Super Unit” on Page 49.
For the purpose of making improvements, the specifications given in this catalog are subject to change without prior notice. Be sure to see the latest model chart.
04
List of Super Unit models
Selecting the optimum model from a wide variety of Super Unit models
Maximum Maximum flow rate Tank
operating Maximum
Series Motor capacity flow rate (L/min) Motor pump type Unit type capacity Page
Equivalent to 2.2 kW pressure
(MPa) (L/min) 10 20 30 40 50 60 70 80 90 100 110 (L)
Nomenclature
a Model No. d Pump discharge rate f Design No. h Hardware Option i Non-standard No.
SUT : SUT series 15: 15 L/min Incremented at Unit cover (SUT06S3016 and N: Without control system
30: 25 L/min model changes 01 A: With control system
30 L tank excluded)
b Tank capacity 40: 40 L/min 30, ....
02 Controller cover (except for 7 kW)
00: Motor pump type 60: 60 L/min 03 DCL (except for 7 kW)
g Function Option
03: 30 L 80: 80 L/min Separate power supplies for
C: With communication function 04 power system and control system
06: 60 L
10: 100 L
e Maximum operating (RS232C)
05 Water fill test compliant tank
16: 160 L pressure P : With analog input function
06 Water leak test compliant tank
07: 7.0 MPa 07 Level switch
c Pump type 10: 10.0 MPa 08 Temperature switch
16: 15.7, 16.0 MPa 09 Thermometer
D: Double pump type
21: 20.6 MPa 10 Micro separator
S : Single pump type
11
Combination of 1 to 10 above
...
Equivalent to 11 kW
SUT 00 S 110 07 40
a b c d e f g h
05
Main features and functions
1 Energy-saving
3 Excluded from high-efficiency motor regulations
Features
Daikin’s original energy-saving motor technology The Super Units that incorporate a
utilizing high-efficiency IPM motors provides an high-efficiency IPM motor are excluded from
energy-saving ratio of 50%. high-efficiency motor regulations.
The motor rotation speed control controls the flow rate and pressure of
the fixed displacement pump.
The highly-efficient motor adopted in this unit achieves energy savings
even in applications for general industrial machinery where actuators
4 Restricted oil temperature rise
Motor speed control also leads to restriction of the oil
have high duty ratios. temperature rise.
The single pump type is a highly-functional series to make it more useful.
The double pump type uses the autonomously-switching, The restricted oil temperature rise inhibits deterioration of the
P T Optional port DR Part No. Name P T Optional port DR Part No. Name
Rc⅜ Rc1 Rp⅜ Rp½ Rp3/4 1 Tank Rc¾ Rc1 Rc¾ Rp⅜ Rp½ Rp¾ 1 Tank
2 Suction strainer 9 2 Suction strainer
3 Stop valve 8 3 Stop valve
4 Oil filler port-cum-air breather 4 Oil filler port-cum-air breather
Above oil level
6-1 5 Oil level gauge 5 Oil level gauge
6-1 Above oil level
6-1 Controller 6-1 Controller
C/R 6-2 Motor pump incorporating an IPM motor
T P b
6-2 Motor pump incorporating an IPM motor
6-2 B A
Rc½
1 2 4 5 1 2 4 5
06
Features Movie of Daikin Hybrid hydraulic unit
URL https://www.daikinpmc.com/en/mv/hybrid_features.html
3 3
2 2
1 1
0 0
Operation time Operation time
Comparison of annual
power consumption Power consumption Annual energy-saving effect
2.5 (average during operation) Decreased by
Power consumption (kW)
Suppression of the temperature rise enabled elimination of the conventionally installed fan
Other cooler, resulting in reduction of the power consumed by the fan cooler on top of the
energy-saving effect of the hydraulic unit itself.
Effects
This is an environmentally friendly hydraulic unit with heat generation reduced, achieving
features including (1) prolonged hydraulic oil life, (2) downsized oil tank, from 150L to 100L,
(3) reduced waste oil disposal volume, and (4) reduced hydraulic oil costs.
Feature
2 Low noise
07
Feature
3 Excluded from high-efficiency motor regulations
High-efficiency motor regulations came into effect in Japan in April 2015.
These regulations apply to the hydraulic units equipped with general motors
but the Super Units that incorporate a high-efficiency IPM motor are
excluded from them.
Eliminates the need for replacement of motors for each destination
Advantages of using Eliminates the need for design changes in accordance with
hybrid hydraulic units amendments to the regulations
Reduces design changes to spare parts, and the maintenance workload
Feature
4 All models conforming to CE standards
All models conform to the machinery directive, EMC directive, and low
Features
voltage directive.
This facilitates CE approval of the main machine.
Feature
5 Restricted oil temperature rise
Restriction of the temperature rise of the hydraulic fluid is one of the effects
achieved by adopting Super Units. This generates the following advantages.
Improved machining accuracy Extended service life of packing and other sealing materials
Reduced thermal distortion Improved maintainability
improves the machining accuracy. Deterioration of the packing and other sealing materials that are made
of rubber, used for hydraulic valves and hydraulic cylinders, is restricted.
Reduced air-conditioning heat load
The reduced heat load on the Extended service life of the hydraulic fluid
air conditioner achieves further Reduced environmental load and improved maintainability
energy savings. Restricted deterioration of the hydraulic fluid extends its
replacement interval.
Feature
6 Fewer control valves required
Elimination of the
proportional Combination flow/single
control valve flow switching valve
M M
Driver Control unit
08
Functions Movie of multi-stage
pressure/flow rate control
URL https://www.daikinpmc.com/en/mv/hybrid_functions.html
The force (pressure) and speed (flow rate) of the actuator (cylinder) can be controlled
with 16 pressure (P) and flow rate (Q) setting patterns.
The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, are not
required. Once the pressure and flow rate have been set at the controller’s operation panel, you can select 16 preset patterns
using external input signals.
The Super Unit autonomously changes the control mode from flow rate control to pressure control (example: flow rate control is
changed to pressure control at the cylinder stroke end).
The solenoid valve that actuates the cylinder must be turned ON/OFF at the machine.
PQ Pattern selection: 0 Pressure: MPa PQ Pattern selection: 1 Pressure: MPa PQ Pattern selection: 2 Pressure: MPa PQ Pattern selection: 3 Pressure: MPa
Speed (mm/s)
Pressurizing force (kN)
160
140
Pressurizing Cylinder speed
force
120
Deceleration low speed
100
Pressure release*
80
60
40 Lowered at
high speed Pressurizing Raised Meter-in control is
20 (3-stage pressuring) performed for pumps.
0
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0
PQ Time (sec)
PQ selection 0 PQ selection 1 selection 2 PQ selection 3 PQ selection 0
PQ pattern selection
*: When pressure release control is disabled, an additional pressure release circuit should be provided for the load side.
Function
2 Maintenance/Management function (Hybrid-Win) Featured with standard models
PC tool This PC utility reads data from Daikin hybrid systems (Super Unit,
EcoRich, oil cooling unit, etc.) and manages it. Parameter setting and
Supported
monitoring can be accomplished efficiently using the Windows application.
09
Function Option
Optional
function C Communication function
IoT-ready
Managing the pressure and flow rate from a machine
・The information that the SUPER UNIT outputs during machine operation, such as pressure and flow
rate, can be displayed on the monitor at a machine.
・By continuously collecting data from the SUPER UNIT, it is possible to determine machining faults,
diagnose machine failures, and utilize the data for predictive maintenance.
∗ RS232C is adopted for the serial communication interface. (For RS485, please consult us.)
Provide a controller such as a PLC or touch panel display with the RS232C communication function at the machine side.
∗ For details on the communication procedure, refer to the communication/remote control function instruction manual.
Functions
Function Option
Application of Super Unit Remote Operation
and Communication Functions
Installation in an
elevated position or at a
distance (within 15 m)
Optional
function P Analog command input
The capability to specify the pressure and flow rate with voltage
ranging from 0 to 10 V enables continuous hydraulic control as
required. Real-time variation in response to commands facilitates
condition settings at the machine side.
A hydraulic control system for machinery that requires variable speed control or
continuity of pressurizing forces can be realized with a simple configuration.
A joystick or trimmer can be connected for real-time control.
10
Hardware Option
Hardware
option 01 With unit cover
Hardware
option 02 With controller cover Example of unit
cover installation
Hardware
option 03 With DCL (DC reactor)
Optionally available for models with motor capacities equivalent to 2.2 kW,
2.8 kW, 3.7 kW, and 5 kW
Appropriate when it is necessary to improve the power factor or reduce the harmonics of the
power supply
Optionally available for compact models with the capacity of 5 kW or smaller. Provided as
standard for models with a capacity of 7 kW or greater.
Hardware
option 04 Separate power supplies for power system and control system
Optionally available for units with motor capacities equivalent to 2.2 kW,
2.8 kW, 3.7 kW, 5 kW, and 7 kW
When an error occurs, only the main power supply is shut down and control power supply
continues to carry current, thereby enabling the alarm code and internal status on occurrence
of an error to be checked on the operation panel or through serial communication.
Hardware
option 05 Water fill test compliant tank Hardware
option 06 Water leak test compliant tank
11
Hardware
option 07 Level switch Hardware
option 08 Temperature switch
Hardware
option 09 Thermometer Hardware
option 10 Micro separator
Separated power
Pump Motor With unit With controller
Model code C P With DCL (03) supply for power/ Tank inspection/
specifications capacity cover (01) cover (02) control systems (04) unit accessory (*)
SUT00S1507-30 − −
Equivalent to
Hardware Option
2.2kW SUT03S1507-30 −
SUT00S3007-30 − −
SUT03S3007-30 −
Equivalent to
2.8 kW SUT00S1510-30 − −
SUT03S1510-30 −
SUT00S4007-30 − −
SUT03S4007-30 −
Single SUT00S3010-30 − −
Equivalent to
pump
3.7 kW SUT03S3010-30 −
SUT00S1516-30 − −
SUT03S1516-30 −
SUT00S3016-30 − −
SUT06S3016-30 −
Equivalent to
5.0 kW SUT00S6007-30 − −
SUT06S6007-30
SUT00S8007-30 − − − −
Equivalent to
7.0 kW SUT10S8007-30 − −
SUT00D4016-30 − −
Equivalent to
3.7 kW SUT06D4016-30
SUT00D6021-30 − −
Double Equivalent to SUT06D6021-30
pump 5.0 kW –
SUT10D6021-30
SUT00D8021-30 − − − −
Equivalent to SUT10D8021-30 − −
7.0 kW
SUT16D8021-30 − −
* Tank inspections : Water fill test compliant tank (05), water leak test compliant tank (06) Available – Not available
Unit accessories : Level switch (07), temperature switch (08), thermometer (09), microseparator (10)
12
Pressure – Flow Rate Characteristics (Typical)
110
SUTS11007
100
90
80 SUTS8007
Flow rate (L/min)
70
60 SUTS6007
50
* Operating flow rate at the maximum
40 SUTS4007
pressure in continuous operation:
30 SUTS3007 SUTS1507: 3 L/min maximum
SUTS3007: 5 L/min maximum
20 SUTS1507
SUTS4007: 8 L/min maximum
10 SUTS6007: 14 L/min maximum
SUTS8007: 19 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS11007: 16 L/min maximum
Pressure (MPa)
SUTS1510, SUTS3010
90
80
70
Flow rate (L/min)
60
50
40
30
SUTS3010
20 SUTS1510
* Operating flow rate at the maximum
10 pressure in continuous operation:
SUTS1510: 3 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS3010: 5 L/min maximum
Pressure (MPa)
SUTS3016, SUTS1516
90
80
70
Flow rate (L/min)
60
50
40
30
SUTS3016
20 SUTS1516
* Operating flow rate at the maximum
10
pressure in continuous operation:
SUTS1516: 5 L/min maximum
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SUTS3016: 5 L/min maximum
Pressure (MPa)
13
Double pump type
SUTD4016 SUTD6021
110 110
100 100
90 90
80 80
70 70
Flow rate (L/min)
50 50
40 40
30 30
20 20
10 10
* Operating flow rate at the maximum pressure in continuous operation: * Operating flow rate at the maximum pressure in continuous operation:
8 L/min maximum 6.5 L/min maximum
SUTD8021 SUTD11021
110 110
100 100
90 90
80 80
70 70
Flow rate (L/min)
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0 5 10 15 20 0 5 10 15 20
Pressure (MPa) Pressure (MPa)
* Operating flow rate at the maximum pressure in continuous operation: * Operating flow rate at the maximum pressure in continuous operation:
14 L/min maximum 16 L/min maximum
14
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 15/30 L/min 110
SUTS11007
Model code 100
SUTS1507-30 90
SUTS3007-30 80 SUTS8007
70
50
40 SUTS4007
30 SUTS3007
20 SUTS1507
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Motor pump type Pressure (MPa)
* The graph shows actual flow rates (representative values).
Unit type
* Operating flow rate at the maximum pressure in continuous operation:
SUTS1507: 3 L/min maximum
SUTS3007: 5 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
General petroleum-based hydraulic oil (R&O) / Wear-resistant hydraulic oil
Usable oil ∗2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Tank oil temperature 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
Operating ambient temperature 0 to 40°C
Storage ambient temperature −20 to 60°C
Operating ambient humidity 85% RH maximum (No condensation)
Operating
conditions Waterproof protection rating (Controller) IP44
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the controller’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
15
External Dimension Diagram
15
SUT00S1507-30
SUT00S3007-30
(254)
Part No. Name Quantity
344
314
1-1 Motor pump incorporating an IPM motor 1
(162)
1-2 Controller 1
2 AC fan 1
4-φ10 holes (for fixing bolts)
(87)
3 Base 1 (M8 bolts recommended)
15
15 490 15
520
DR Rc⅜
(83) (Fitted with a vinyl cap at shipment)
(421)
(260)
(246)
nameplate
(220)
(109)
45
45
Suction port: G¾
30 284 30
50
4-M8
(Manifold bracket mount) 1 Oil tank 1
100
6-2 Controller 1
Pressure indication and
operation panel
196
Foundation plate (Option)
(E-SUTPLATE-2)
7 Oil cooler 1 15/
(40) (620) (40) 4-φ15 holes (for fixing bolts)
(M12 bolts recommended)
8 AC fan 1 30
L/min
6-2 5 4
φ21 hole Cleaning port
30 L
φ28 hole Safety caution Upper limit (Yellow line) 1
(Power cable port) nameplate Cleaning port tightening caution nameplate
SUT03S15L07-30
23 L
Unit nameplate 2
7 Lower limit (Red line)
Suction air
462
(516)
6-1
419
8
20
ボルト
注意銘板
95
70
(50)
155
70
40
450
25
20 10 30 30
500
85 530 85
(550)
700
Wing bolt for fastening during transportation (580)
2-M8 (through hole)
(at 1 location on the back) Tapped holes for mounting
(To be removed before operation) the foundation plate
(at 4 locations)
16
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 40 L/min 110
SUTS11007
Model code 100
SUTS4007-30 90
80 SUTS8007
70
50
40 SUTS4007
30 SUTS3007
20 SUTS1507
10
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 64
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
17
External Dimension Diagram
P Rc½
Motor pump type (Fitted with a vinyl cap at shipment)
Pressure indication and operation panel
15
SUT00S4007-30
(294)
384
354
1-1 Motor pump incorporating an IPM motor 1
(202)
1-2 Controller 1
2 AC fan 1
3 Base 1 4-φ10 holes (for fixing bolts)
(87) (M8 bolts recommended)
15
15 490 15
520
DR Rc⅜
(83) (Fitted with a vinyl cap at shipment)
(421)
Suction
Unit nameplate
(466)
air
Suction air Safety caution
Wing bolt for fastening during nameplate 1-1
transportation (at 1 location)
(259)
(245)
220
(108)
45
45
Unit type
50
92
1 Oil tank 1
4-M8
100
(Manifold bracket
(Manifold bracket mount)
mount)
2 Suction strainer 1
3 3 Stop valve 1
Optional port: Rp½
4 Oil level gauge 1
Optional port: Rp⅜
5 Oil filler port-cum-air breather 1 7
MPa
P Rc½ 6-1 Motor pump incorporating an IPM motor 1
(Fitted with a vinyl cap at shipment)
6-2 Controller 1
140.5
30 L 1
φ28 hole Safety caution
Safety caution Upper limit (Yellow line)
nameplate
(Power cable port) nameplate Cleaning port tightening caution nameplate
EHU40R-M0703-30
EHU40R-M0703-30 23 L
Unit nameplate
Lower limit (Red line) 2
7
(516)
462
Suction air
6-1
419
Bolt
Caution nameplate
95
155
(50)
70
70
40
18
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 60 L/min 110
SUTS11007
Model code 100
SUT00S6007-30 90
SUT06S6007-30 80 SUTS8007
70
50:
40 SUTS4007
30 SUTS3007
20 SUTS1507
10
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 56 97
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
19
External Dimension Diagram
15
(Fitted with a vinyl cap at shipment)
SUT00S6007-30
(73)
Part No. Name Quantity
1-1 Motor pump incorporating an IPM motor 1
(294)
384
354
1-2 Controller 1
(180)
2 AC fan 1
(95)
3 Base 1
4-φ10 holes (for fixing bolts)
4 Check valve 1 (136)
(M8 bolts recommended)
15
15 578 15
608
DR Rc⅜
(Fitted with a vinyl cap at shipment)
(421)
(466)
Unit nameplate
Suction ********
air Safety caution
Unit nameplate
Wing bolt for fastening during nameplate 1-1
(282)
transportation (at 1 location) Safety caution
(241)
(226)
(To be removed before operation) nameplate
2
(95)
45
30 324 30 (86)
Unit type
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
85 100 327 188
T Rc1
(Fitted with a vinyl cap at shipment)
150 170
SUT06S6007-30
37
42
50
1 Oil tank 1
(311)
P Rc¾
6-1
6-2
Motor pump incorporating an IPM motor
Controller
1
1
7
(Fitted with a vinyl cap at shipment) 7 Oil cooler 1
MPa
Foundation plate (Option) 8 AC fan 1
4-φ15 holes (for fixing bolts) Pressure indication and operation panel (E-SUTPLATE-2) 9 Return filter 1
(M12 bolts recommended) 10 Check valve 1
(40) (620) (40)
60
L/min
4 1
9 5
6-2 10
60 L
Safety
Unit nameplcaution
ate Upper limit (Yellow line)
nameplate
Safety caution
nameplate
Unit nameplate 45 L
Lower limit (Red line)
6-1
639
716
7
595
Cleaning port
Suction
(441)
air
8
20
Bolt
Caution nameplate
95
70
70
(50)
20
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 80 L/min 110
SUTS11007
Model code 100
SUTS8007-30 90
80 SUTS8007
70
50
40 SUTS4007
30 SUTS3007
20 SUTS1507
10
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 72 131
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 100
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
21
External Dimension Diagram
15
SUT00S8007-30 P Rc¾
(Fitted with a vinyl cap at shipment)
294
1-1 Motor pump incorporating an IPM motor 1
384
354
1-2 Controller 1
(196)
2 AC fan 1
(125)
3 Base 1
4 Check valve 1 4-φ10 holes (for fixing bolts)
(135) (M8 bolts recommended)
15
15 600 15
(60) 630
1-2
4 DR Rc⅜
(Fitted with a vinyl cap at shipment)
1-1
(441)
(486)
Unit
nameplate
(408)
Suction air (85.5)
Safety caution
(300)
(244)
nameplate
(260)
(90)
Transportation nameplate
45
Unit type
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
T Rc1-½ (85) 100 (327) (188)
(Fitted with a vinyl cap at shipment)
150 170 SUT10S8007-30
17
100 50
1 Oil tank 1
2 Suction strainer 1
3 Stop valve 1
(439)
4-M8
T Rc1-¼ (Manifold bracket mount) 4 Oil level gauge 1
(Plugged at shipment)
5 Oil filler port-cum-air breather 1
Pressure indication and operation panel
Optional port: Rp⅜
3 6-1
6-2
Motor pump incorporating an IPM motor
Controller
1
1
7
7 Oil cooler 1
MPa
Optional port: Rp½
P Rc¾
8 AC fan 1
4-φ15 holes (for fixing bolts) (Fitted with a vinyl cap
at shipment) 9 Return filter 1
(M12 bolts recommended)
10 Check valve 1
80
(40) (620) (40)
Foundation plate (Option)
(E-SUTPLATE-2) Cleaning port L/min
6-2 9 4
5
SUT10D80L07-30 100 L
10 Unit nameplate Upper limit
Safety
Safetycaution
caution (Yellow line)
nameplate
nameplate
7 76 L
Lower limit
754
(Red line)
8
671
(647)
1
(441)
Suction
air 2
(216)
20
Bolt
Caution nameplate
95
155
70
70
(50)
40
85 530 85 580
Tapped holes for mounting
(188) 700 630
the foundation plate (at 4 locations)
(895) Oil sampling port/
Oil drain port: Rc½
Wing bolt for fastening during transportation (at 1 location on the back)
(To be removed before operation)
22
Super Unit
[Single pump type]
Maximum
operating
pressure 7 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 110 L/min 110
SUTS11007
Model code 100
SUT00S11007-40 90
80 SUTS8007
70
50
40 SUTS4007
30 SUTS3007
20 SUTS1507
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pressure (MPa)
Motor pump type
* The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
16 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 112
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
Operating hydraulic oil
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) −
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
23
External Dimension Diagram
87
SUT00S--A-
MFG No.: Note 1.
INSULATION CLASS: F
151
MASS : 88 kg
V Hz A PF
MAX. FLOW : 80 L/min 3φ 200 50: 62 0.94
MAX.PRESSURE : 17.6 MPa 3φ 200 60 62 0.94
3φ 220 60 61 0.94
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■
■■■■■■■■■■■■
Suction
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
**
air
D □EC
IN C
261
243
228
207
170
129
112
95
4-14.5 (Installation)
15
Control unit
SUT00D11021-40
Controller (Installed separately)
<Top>
11.5
7
180
Cooling fan
exhaust
User I/O terminal (M3)
MPa
34
• Encoder
• Motor thermistor
• Pressure sensor
FG
FG
GND
+5V
• I/O signal Z+
Z-
Operation panel
110
危 険
B- WARNING
B+
A- 感電のおそれがあります。
A+ ・通電中及び電源遮断後5分以内は
ターミナルカバーを開けないで下さい。
THM- May cause
THM+ electric shock.
AGND
L/min
AO2 ・Disconnect all power
before opening terminal
(QO)AGND cover of unit.
AO1 Wait 5 minutes until
DC Bus capacitors
(PO) dischange.
Product nameplate
DAIKIN INDUSTRIES,LTD.
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
A5V
233
ALM_C
ALM_B
ALM_A
3φ 220 60
361
DO2
DO1
DI8
• DC reactor
DI7
DI6
DI5
DI4
DI3
DI1
DI2 • Regenerative resistor
DGND
DICOM
RxD
• Motor output
TxD
FG
FG
Electromagnetic valve
Controller nameplate terminal block (M4)
M5 screw • Electromagnetic valve power supply
(for ground connection) • AC fan power supply
39
Cooling fan 25 180 (25)
6
17
suction
207 (5) (5) 230 (5)
212 240
24
Super Unit
[Single pump type]
Maximum
operating
pressure 10 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 15 L/min
90
Model code
80
SUTS1510-30
70
50
40
30 SUTS3010
20 SUTS1510
10
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 39 59
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
25
External Dimension Diagram
15
Part No. Name Quantity
1-1 Motor pump incorporating an IPM motor 1
(254)
344
314
1-2 Controller 1
(162)
2 AC fan 1
3 Base 1
4-φ10 holes (for fixing bolts)
(M8 bolts recommended)
15
(87)
φ28 hole 15 490 15
(Power cable port) φ21 hole
(Signal cable port) 520
1-2
DR Rc⅜
(Fitted with a vinyl cap
at shipment)
(83)
(421)
Unit nameplate
transportation (at 1 location) Suction
(To be removed before operation) air Safety caution 1-1
nameplate
(260)
(246)
(220)
(109)
45
45
Suction port: G¾
3 (Fitted with a vinyl cap
30 284 30 30 460 30
at shipment)
344
520
50
92
T Rc1 (Manifold
(Manifoldbracket mount)
bracket mount)
1 Oil tank 1
(Fitted with a vinyl cap
at shipment) 2 Suction strainer 1
3
Optional port: Rp⅜
P Rc⅜ 3 Stop valve 1
(Fitted with a vinyl cap at shipment)
4 Oil level gauge 1
5 Oil filter port-cum-air bleeder 1
140.5
6-2 5 4
φ21 hole
(Signal cable port)
Cleaning port
15
L/min
φ28 hole 30 L
Safety caution
(Power cable port) nameplate Upper limit (Yellow line) 1
Cleaning port tightening caution nameplate
SUT03S15L10-30 23 L
Unit nameplate 2
7 Lower limit
(Red line)
(516)
462
Suction air
6-1
419
Bolt
Caution nameplate
95
155
70
70
40
20 10 30 30 450
25
85 530 85 500
700 (550)
Wing bolt for fastening during transportation 2-M8 (through hole) (580)
(at 1 location on the back)
(To be removed before operation) Tapped holes for mounting
the foundation plate (at 4 locations)
26
Super Unit
[Single pump type]
Maximum
operating
pressure 10 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 30 L/min
90
Model code
80
SUTS3010-30
70
50
40
30 SUTS3010
20 SUTS1510
10
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
5 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 64
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
27
External Dimension Diagram
15
SUT00S3010-30
(294)
1-1 Motor pump incorporating an IPM motor 1
384
354
1-2 Controller 1
(202)
2 AC fan 1
3 Base 1
4-φ10 holes (for fixing bolts)
(87) (M8 bolts recommended)
15
15 490 15
520
DR Rc⅜
(Fitted with a vinyl cap at shipment)
(83)
(421)
(466)
Unit nameplate
Suction
Safety caution
Wing bolt for fastening during air
nameplate 1-1
transportation (at 1 location)
(259)
(245)
220
(108)
45
3 Suction port: G¾
30 324 30 30 460 30 (Fitted with a vinyl cap at shipment)
384 520
132.5 550
177.5
150 170
SUT03S3010-30
77.5
42
50
4-M8
1 Oil tank 1
100
6-2
Cleaning port
φ21 hole
(Signal cable port) 5 4 30
L/min
1
Safety 30 L
φ28 hole Safety caution
caution Upper limit (Yellow line)
nameplate
nameplate
(Power cable port) Cleaning port tightening caution nameplate
SUT03S30L10-30
23 L
Unit nameplate
7 Lower limit
(Red line)
(516)
462
Suction air
419
6-1
(309)
8 2
20
Bolt
ボルト
Caution
注意銘板 nameplate
95
155
70
(50)
70
40
20 10 30 30
25
28
Super Unit
[Single pump type]
Maximum
operating
pressure 16 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 15/30 L/min
90
Model code
80
SUTS1516-30
SUTS3016-30 70
50
40
30
SUTS3016
20
SUTS1516
10
Pressure (MPa)
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
5 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 46 52 64 83
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 30 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
29
External Dimension Diagram
15
(Fitted with a vinyl cap at shipment)
SUT00S1516-30
(294)
384
354
SUT00S3016-30
(202)
Part No. Name Quantity
Motor pump incorporating 4-φ10 holes (for fixing bolts)
1-1 1 φ28 hole φ21 hole (137) (77)
an IPM motor 15 578 (490) 15 (M8 bolts recommended)
15
(Power cable port) (Signal cable port) 608 (520)
1-2 Controller 1
1-2
2 AC fan 1
DR Rc⅜
3 Base 1 (Fitted with a vinyl cap at shipment)
(133) (73)
(421)
(466)
Unit nameplate
Suction Safety caution
********
(260)
Safety caution
(245)
2 nameplate
220
(To be removed before operation)
(109)
3
(45)
45
30 324 30 30 548 (460) 30
384 608 (520) Suction port: G¾
(Fitted with a vinyl cap
at shipment)
Unit type 132.5 550
(): Dimensions for SUT00S1516-30
DR Rp¾ (above oil level) 177.5 4-M8
150 170
(Fitted with a vinyl cap at shipment) (Manifold bracket mount)
77.5
42
100 50
SUT03S1516-30
92
T Rc1
(Fitted with a vinyl cap Optional port: Rp½
at shipment)
Optional port: Rp⅜ 3
Part No. Name Quantity P Rc⅜
(Fitted with a vinyl cap at shipment)
1 Oil tank 1
140
6-2 Controller 1
(516)
23 L
Suction Lower limit 462
419
2
8 6-1
8 AC fan 1
20
95
155
70
70
(50)
40
20 10 30 30
25
450
85 530 85 2-M8 (through hole)
500
700 Tapped holes for mounting
Wing bolt for fastening during transportation the foundation plate (at 4 locations) Oil sampling port/
(at 1 location on the back) Oil drain port: Rc½
(To be removed before operation)
DR Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
SUT06S3016-30 T Rc1
(Fitted with a vinyl cap at shipment)
85 100 186
4-M8
150 170
(Manifold bracket mount)
37
42
100 50
T Rc¾
(360)
7
639
716
595
9 Return filter 1
Suction air 1
8
309
2
20
95
155
70
70
(50)
40
Wing bolt for fastening during transportation 85 530 85 500 Oil drain port: Rc½
(at 1 location on the back) 2-M8 (through hole)
700
(To be removed before operation) Tapped holes for mounting the
foundation plate (at 4 locations)
30
Super Unit
[Double pump type]
Maximum
operating
pressure 16 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 40 L/min 110
Model code 100
SUTD4016-30 90
80
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
8 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 53 94
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
31
External Dimension Diagram
(146) P Rc¾
15
(Fitted with a vinyl cap at shipment)
SUT00D4016-30
(73)
Part No. Name Quantity
(294)
1-1 Motor pump incorporating an IPM motor 1
384
354
1-2 Controller 1
(180)
2 AC fan 1
(95)
3 Base 1
4-φ10 holes (for fixing bolts)
4 Check valve 1 (142) (M8 bolts recommended)
15
15 578 15
φ28 hole φ21 hole 608
(Power cable port) (Signal cable port)
1-2
4 DR Rc⅜
(Fitted with a vinyl cap at shipment)
(421)
(466)
Unit nameplate
Suction air Safety caution
nameplate Unit nameplate
Wing bolt for fastening during 1-1
(282)
transportation (at 1 location) Safety caution
2
(226)
220
(95)
45
45
Unit type
50
2 Suction strainer 1
(309)
T Rc¾
(Plugged at shipment) 3 Stop valve 1
Optional port: Rp⅜
4 Oil level gauge 1
3 5 Oil filler port-cum-air breather 1
Optional port: Rp½ 6-1 Motor pump incorporating an IPM motor 1
6-2 Controller 1
P Rc¾
(Fitted with a vinyl cap at shipment) 7 Oil cooler 1
8 AC fan 1
Foundation plate (Option)
4-φ15 holes (for fixing bolts) (E-SUTPLATE-2)
9 Return filter 1
Pressure indication and operation panel
(M12 bolts recommended) 10 Check valve 1
(40) (620) (40)
9 5
4 1 16
6-2 10 MPa
60 L
Unit nameplate Upper limit
Safety caution (Yellow line)
nameplate
45 L
Lower limit 40
(Red line) L/min
716
639
6-1
595
7 Cleaning port
(441)
Suction air
8
20
Bolt
Caution nameplate
95
70
(50)
70
32
Super Unit
[Double pump type]
Maximum
operating
pressure 21 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 60 L/min 110
Model code 100
SUTD6021-30 90
80
Pressure (MPa)
Unit type
* The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
6.5 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 58 99 112
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 60 100
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
33
External Dimension Diagram
P Rc¾
(Fitted with a vinyl cap at shipment) (140)
Motor pump type
15
(73)
SUT00D6021-30
(294)
384
354
(180)
(95)
Part No. Name Quantity
Motor pump incorporating Pressure indication and operation panel 4-φ10 holes (for fixing bolts)
1-1 1 φ28 hole φ21 hole
15 578
(136)
15 (M8 bolts recommended)
15
an IPM motor (Power cable port) (Signal cable port) 608
1-2 Controller 1 Unloading port Rc½
1-2 (Fitted with a vinyl cap at shipment)
2 AC fan 1
4
3 Base 1 DR Rc⅜
(Fitted with a vinyl cap at shipment)
4 Check valve 1
(466)
Suction Safety caution
Wing bolt for fastening during air Unit nameplate
nameplate 1-1
(282)
transportation (at 1 location) Safety caution
(241)
(226)
(To be removed before operation) 2 nameplate
(95)
(45)
45
30 324 30 (86) Suction port: Rc1
3
384 (142.5) (Fitted with a vinyl cap
608 at shipment)
DR Rp¾ (above oil level)
Unit type T Rc1
(Fitted with a vinyl cap at shipment)
85 100 327 188
(Fitted with a vinyl cap at shipment) 4-M8
150 170
(Manifold bracket mount)
42
110 37
100 50
SUT06D6021-30
(309)
T Rc¾
(Plugged at shipment)
Optional port: Rp⅜ 3
Part No. Name Quantity
Optional port: Rp½
P Rc¾
1 Oil tank 1
(Fitted with a vinyl cap at shipment)
2 Suction strainer 1 4-φ15 holes (for fixing bolts) Foundation plate (Option)
(M12 bolts recommended)
3 Stop valve 1 (E-SUTPLATE-2)
4
4 Oil level gauge 1 9 6-2 5
716
6-1
Cleaning port tightening caution nameplate
639
595
1
8 AC fan 1 8
2
20
9 Return filter 1
95
155
70
70
(50)
40
Wing bolt for fastening during transportation 85 530 85 2-M8 (through hole) 500 Oil drain port: Rc½
(at 1 location on the back) 700
(To be removed before operation) Tapped holes for mounting
the foundation plate (at 4 locations)
85 100 327 188
DR Rp¾ (above oil level) 4-M8
150 170
SUT10D6021-30 (Fitted with a vinyl cap (Manifold bracket mount)
at shipment)
100 50
167
172
T Rc1
Part No. Name Quantity (Fitted with a vinyl cap
(439)
at shipment)
110
7 1
648
639
6-1
595
9 Return filter 1
Suction air 2
(441)
95
155
70
70
(50)
40
34
Super Unit
[Double pump type]
Maximum
operating
pressure 21 MPa Pressure – Flow rate characteristics (Representative)
Maximum
flow rate 80 L/min 110
Model code 100
90
SUTD8021-30
80
Pressure (MPa)
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
14 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 72 133 145
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 100 160
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
35
External Dimension Diagram
15
(139)
operation panel 4
P Rc¾
(Fitted with a vinyl cap at shipment)
384
354
294
Part No. Name Quantity
(196)
1-1 Motor pump incorporating an IPM motor 1
(125)
1-2 Controller 1
2 AC fan 1
4-φ10 holes (for fixing bolts)
3 Base 1 (97)
(M8 bolts recommended)
15
4 Check valve 1 15 600 15
(60) 630
1-2
DR Rc⅜
(Fitted with a vinyl cap at shipment)
(441)
Unit
483
nameplate
(408)
Suction air (72)
Safety caution
(311)
1-1
(299)
nameplate
2
258
(90)
Transportation nameplate
45
30 324 30 (142)
3 Suction port: Rc1
30 570 30 (Plugged (with O-ring) at shipment)
Wing bolt for fastening during transportation (at 2 locations)
(To be removed before operation)
Unit type
700
85 100 327 188
T Rc1-½ 150 170
SUT10D8021-30
17
T Rc1-¼
3 Stop valve 1
(Plugged at shipment)
4 Oil level gauge 1
DR Rp¾ (above oil level) 5 Oil filler port-cum-air breather 1
(Fitted with a vinyl cap 6-1 Motor pump incorporating an IPM motor 1
at shipment)
6-2 Controller 1
7 Oil cooler 1
Optional port: Rp⅜ 3
8 AC fan 1
Optional port: Rp½
P Rc¾ 9 Return filter 1
(Fitted with a vinyl cap at shipment) 10 Check valve 1
Foundation plate (Option)
4-φ15 holes (for fixing bolts)
(E-SUTPLATE-2)
(M12 bolts recommended)
(40) (620) (40)
Cleaning port
9 4
5
6-2
21
10
164 L (100 L)
Unit nameplate Upper limit (Yellow line)
Safety caution MPa
nameplate 124 L (76 L)
Lower limit (Red line)
754
7
(647)
671
6-1
Cleaning port tightening caution nameplate
1
80
595
8
2
(441)
L/min
Oil sampling port/
Suction Oil drain port: Rc½
(216)
air
20
95
70
155
40
during transportation
(at 1 location on the back) 20 10 30 30 450 50 290 (80)
25
36
Super Unit
[Double pump type]
21 MPa
Maximum
operating Pressure – Flow rate characteristics (Representative)
pressure
Maximum
flow rate 110 L/min 110
Model code 100
90
SUT00D11021-40
P-SUT20D11KW-40 80
Pressure (MPa)
Unit type * The graph shows actual flow rates (representative values).
* Operating flow rate at the maximum pressure in continuous operation:
16 L/min maximum
External Digital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
output signal Contact output 1 channel (1 common contact), dry contact Contact capacity: DC 30 V, 0.5 A (resistance load)
Mass (kg) 112 360
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil
Usable oil *2 • Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s
• Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
Operating hydraulic 0 to 60°C (Recommended operating temperature range: 15 to 50°C)
oil temperature (in tank)
Operating ambient temperature 0 to 40°C
Storage ambient temperature –20 to 60°C
Operating
conditions Operating ambient humidity 85% RH max. (no condensation)
Installation site Indoors (Be sure to secure the unit with bolts.)
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.
• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.
Others • Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.
• Be sure to connect the ground terminal.
Tank capacity (L) − 200
Standard coating color Ivory white (Munsell code 5Y7.5/1)
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.
*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil. Keep the contamination level of the hydraulic
fluid within NAS contamination class 10 for operating pressures of 7 MPa or lower.
*3: The unit incorporates a safety valve.
*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics and how to select a unit” on Page 49.
For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
37
External Dimension Diagram
819
SUT00D11021-40
151
134
Motor wiring port (φ28)
AC fan, thermistor wiring port (21)
Drain port
Rc⅜
323
168 496
19
Unloading port
Discharge port Rc¾
Rc1−¼
199
Suction
314
air
24: 3
228
207
170
112
4-14.5 (installation)
170
108 108
241 228
275
Unit type
1,376
1,088 288 Drain port: Rc¾
(Fitted with plastic plug)
43 1,002 43
P-SUT20D11KW-40
120
2 Motor pump 1
352
6 Return filter 1
4
7 Oil cooler 1
600
8 Pressure gauge 1
DAIKIN
9 Thermometer 1
10 Outlet block 1
G1/2
11 Vibration-absorbing rubber 6
12 Foundation plate 1
(10)
2 13 Electrical cabinet 1
6 7 13
8 3
10
21
Super Unit switch board
Tank 1: Rc1-½ Discharge port: Rc1
(Fitted with plastic plug) (Fitted with plastic plug)
3
MPa
OIL HYDRAULIC UNIT
Safety caution
nameplate
Oil level
1,150
gauge guard
Suction
Thermometer
L/min
942
920
air 1
866
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■
■■■■■■■■■■■■
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
DAIKIN
9
300
210
210
( )
The base plates (4 pcs.) provided as accessories 838
can be mounted at the desired positions. (Fitted with high-pressure plug)
(Accessories, supplied with 8 bolts)
Secure the unit before using it.
38
Operation Panel
Using the key switches on the Super Unit controller, you can monitor the pressure and flow rate and set or
change parameters.
Outline of Functions
NO. Item Description
Mode selection
To go to the monitor mode or return to the normal mode from other modes, press the key.
To go to other modes, press and hold down a combination of relevant keys for 2 seconds.
Normal mode
Hold down for more Hold down for more Hold down for more
than two seconds. than two seconds. than two seconds.
39
Monitor mode
Alternately displays the high (single flow) and low (combination flow) flow
n02 Flow rate setting L/min
rate settings for the current P-Q selection number.
n03 Flow rate L/min Displays the current flow rate (theoretical value).
Displays the alarm code of the alarm that occurred most recently.
—
n04 *2 Latest alarm code The current power ON count can be checked by pressing the key.
Press the key to check how many times the power has been turned on so far.
n05 Motor rotation speed ×10min−1 Displays the current rotation speed of the motor.
[SUTD]
Displays the solenoid valve switching status: “Low pressure [L]” (combination
flow) or “High pressure [H]”(single flow), and the P-Q selection number.
Displays the total number of rotations of the motor when it rotates in the
min−1 reverse direction due to reverse flow from the load when the power supply
n07 Reverse rotations at power OFF for the unit is turned OFF.
This value is used to estimate the machine load volume.
n11 Heat emission fin temperature °C Displays the temperature of the heat emission fins of the controller.
Operation Panel
Displays the controller’s internal circuit voltage.
The indicated voltage is a value equivalent to "power supply voltage 2".
n12 Main circuit DC voltage V The main circuit voltage may vary depending on the operating conditions
and momentarily exceed 350 V due to a regenerative current during
deceleration and other operations. However, this is not abnormal.
n13 *3 Pressure command Displays the input voltage at analog input terminal AIN1.
n14 *3 Flow rate command Displays the input voltage at analog input terminal AIN2.
—
n15 *3 Actual pressure Displays the output voltage at analog output terminal AO1.
n16 *3 Actual flow rate Displays the output voltage at analog output terminal AO2.
*1: The default setting is displayed in MPa (standard display unit). If you change the display unit to PSI, ensure that you indicate in some manner that the monitor value
is displayed using the PSI unit (attach a label, etc). However, use of the PSI unit in Japan is subject to punishment under the Measurement Law. Users should
supply their own unit indication labels.
*2: You can check the current power ON count by pressing the key when an alarm code is displayed. For details on alarm codes, refer to the alarm descriptions in the Operation Manual.
*3: Enabled only when equipped with function option P (analog input function)
Setting mode
The following data can be set in the setting mode.
For details on the settings, refer to the Operation Manual of the relevant model since they vary depending on the model.
The pressure, flow rate, acceleration time, deceleration time, Dry run judging pressure, time, etc.
etc., to be set for multi-stage pressure/flow rate control
Various control gains
Enable/disable setting of pressure switch functions
Display unit selection
40
Electric Wiring
SUTS8007-30, SUTD8021-30
Internal terminal layout (with the controller cover open)
* Main power supply connections: Connect a 3-phase AC power supply (200 V/50 Hz, 200 V/60 Hz, or 220 V/60 Hz) to the power supply terminals
(L1, L2 and L3), and connect a ground cable to the ground terminal.
* I/O signal connections: Connect digital input terminals, digital output terminals, and contact output terminals as shown on Page 42.
41
SUT00S11007-40, SUT00D11021-40, P-SUT20D11KW-40
Pressure sensor
Z-
Z+ 危 険
B- WARNING
B+
I/O signal
A-
A+
THM- May cause
THM+ electric shock.
AGND
AO2 before opening terminal
(QO) AGND cover of unit.
AO1 Wait 5 minutes until
DC Bus capacitors
(PO) dischange.
DAIKIN INDUSTRIES,LTD.
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6 A PF
DO5
DO4
DO3
DO2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
block (M5)
Main power supply
DC reactor Solenoid valve terminal block (M4)
Regenerative resistor Solenoid valve power supply
Motor output AC fan power supply
DO2
DIN2 2.2 kΩ
Load
4.7 kΩ OCOM
DIN3 2.2 kΩ
Electric Wiring
* The maximum output current of the output circuit is 50 mA per channel.
DIN4 2.2 kΩ
AIN1 AO1
Pressure command input Pressure monitor output
AGND AGND V
0 to 10 V −10 to 10 V
AIN2 AO2
Flow rate command input Flow rate monitor output
AGND AGND V
0 to 10 V −10 to 10 V
42
Harness specifications(to be prepared by the customer)
The harnesses that need to be prepared by the customer are as follows.
Power supply cable I/O signal cable
Model code Recommended Recommended Recommended Recommended
Cable size Recommended cable crimp terminal cable clamp Cable size cable cable clamp
SUTS1507
SUTS3007 OA-W2213
SUTS1510 2.5 mm2 or more
CE362 2.5 mm2 × 4 wires (OHM ELECTRIC)
(AWG14 or RBV2-4
SUTS3010 (KURAMO ELECTRIC) Applicable cable outer
larger size)
SUTS1516 diameter: φ9 to φ13 0.3 to 0.5 mm2
SUTS3016 (AWG20 to 22)
OA-W2216
4.0 mm2 or more
CE362 4.0 mm2 × 4 wires (OHM ELECTRIC)
SUTS6007 (AWG12 or RBV5.5-4
(KURAMO ELECTRIC) Applicable cable outer
larger size)
diameter: φ13 to φ16
OA-W2219
6.0 mm2 or more OA-W1611
CE362 6.0 mm2 × 4 wires (OHM ELECTRIC) 0.3 to 1.0 mm2
SUTS8007 (AWG10 or RBV5.5-5 (OHM ELECTRIC)
(KURAMO ELECTRIC) Applicable cable outer (AWG16 to 22)
larger size) Applicable cable
diameter: φ15 to φ19
KVC-36SB outer diameter:
0.3 - 0.5 mm2 φ9 to φ11
OA-W2216
2.5 mm or more
2
CE362 2.5 mm2 × 4 wires (OHM ELECTRIC)
SUTD4016 (AWG14 or (KURAMO ELECTRIC) RBV2-4 Applicable cable outer
larger size) diameter: φ13 to φ16
0.3 to 0.5 mm2
OA-W2216 (AWG20 to 22)
4.0 mm or more
2
CE362 4.0 mm2 × 4 wires (OHM ELECTRIC)
SUTD6021 (AWG12 or
Applicable cable outer
(KURAMO ELECTRIC)
larger size)
diameter: φ13 to φ16
RBV5.5-5
OA-W2219
6.0 mm or more
2
CE362 6.0 mm2 × 4 wires (OHM ELECTRIC) 0.3 to 1.0 mm2
SUTD8021 (AWG10 or (KURAMO ELECTRIC) Applicable cable outer (AWG16 to 22)
larger size) diameter: φ15 to φ19
SUT00S11007 CE362 10.0 mm2 × 4 wires 0.3 to 0.5 mm2
10 mm2 or more R8-5 - -
SUT00D11021 (KURAMO ELECTRIC) (AWG20 to 22)
43
Options (Separately available parts)
Unit accessory
The following optional parts can be purchased separately from the Super Unit.
These parts are to be mounted by the user.
Example of installation
25 25
Base plate
2-C3
dimensions
25
φ15 hole
10 30 10
40
25
40 50:
Level switch
Operating Operating Contact Protection
Model code Oil level triggering alarms CE standard
voltage current resistance class
SUT03 (with 30 L tank) 21 L maximum Closed
SUT06 (with 60 L tank) 50 L maximum Closed
E-DLSN-130L-A-10 SUT10 (with 100 L tank) 83 L maximum Closed
SUT16 (with 160 L tank) 135 L maximum Closed
SUT03 (with 30 L tank) 21 L maximum Open
SUT06 (with 60 L tank) 50 L maximum Open
E-DLSN-130L-B-10 SUT10 (with 100 L tank) 83 L maximum Open
AC 100/110 V 0.02 A
1 Ω maximum IP65 SUT16 (with 160 L tank) 135 L maximum Open N/A
Electric Wiring
Options (Separately available parts)
DC 24 V 0.05 A
SUT06 (with 60 L tank) 45 L maximum Closed
E-DLSN-170L-A-10 SUT10 (with 100 L tank) 75 L maximum Closed
SUT16 (with 160 L tank) 123 L maximum Closed
SUT06 (with 60 L tank) 45 L maximum Open
E-DLSN-170L-B-10 SUT10 (with 100 L tank) 75 L maximum Open
SUT16 (with 160 L tank) 123 L maximum Open
* Directly mountable on the Rc1/2 option port on the top face of each tank.
Temperature switch
Operating Operating Contact Protection
Model code Oil level triggering alarms CE standard
voltage current resistance class
AC 100 V 2A
E-MQT83PD-L60X1-10 30 mΩ maximum IP65 60°C N/A
DC 24 V 50 mA
* Directly mountable on the Rc3/8 option port on the top face of each tank.
44
Bracket/Piping Set for Manifolds
In order to install a control system on the Super Unit, select a bracket and piping set for the manifold according to the
control system’s size and number of series. Please prepare a manifold block separately.
Component parts
Manifold bracket
Model code Maximum installable series Accessories
E-SUT03BASE-402 4-series Hexagon socket head cap
E-SUT06BASE-302 3-series bolt for mounting manifold
• Bracket body 1 pc. (M8 × 85) 2 pcs.
E-SUT06BASE-602 6-series
• Hexagon bolt (M8 × 16) 4 pcs.
E-SUT03BASE-203 2-series • Flat washer (M8) 4 pcs. Hexagon socket head cap
E-SUT06BASE-203 2-series bolt for mounting manifold
E-SUT06BASE-403 (M8 × 105) 4 pcs.
4-series
45 IN V E RT ER H Y D R A U LIC U N IT
Piping set
Part Configuration 1
7
6 5
1
8
• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 54.0 to 66.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 43.0 to 47.5
E-SUT03S1507N-PIPE-02 3 Hose adaptor (elbow) 1 43.0 to 47.5 E-SUT03S1507N-PIPE-03 3 Hose adaptor (elbow) 1 64.0 to 70.0
E-SUT03S1510N-PIPE-02 4 ― ― ― E-SUT03S1510N-PIPE-03 4 Bushing 1 110.0 to 120.0
E-SUT03S1516N-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT03S1516N-PIPE-03 5 Steel pipe 1 247.0 to 286.0
E-SUT03S3007N-PIPE-02 6 Steel piping joint (straight) 1 28.5 to 33.0 E-SUT03S3007N-PIPE-03 6 Steel piping joint (straight) 1 95.0 to 110.0
E-SUT03S3010N-PIPE-02 7 Steel piping joint (elbow) 1 28.5 to 33.0 E-SUT03S3010N-PIPE-03 7 Steel piping joint (elbow) 1 57.0 to 66.0
8 Bushing 1 95.0 to 110.0 8 ― ― ―
9 Installation guide 1 ― 9 Installation guide 1 ―
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 64.0 to 70.0 2 Hose adaptor (straight) 1 64.0 to 70.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
4 ― ― ― 4 ― ― ―
E-SUT03S4007N-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT03S4007N-PIPE-03 5 Steel pipe 1 247.0 to 286.0
6 Steel piping joint (straight) 1 28.5 to 33.0 6 Steel piping joint (straight) 1 95.0 to 110.0
7 Steel piping joint (elbow) 1 28.5 to 33.0 7 Steel piping joint (elbow) 1 57.0 to 66.0
8 Bushing 1 95.0 to 110.0 8 ― ― ―
9 Installation guide 1 ― 9 Installation guide 1 ―
Part Configuration 2 5 8 Mounted in the port at the back of the return filter
6 1
6
3 4
(Separately available parts)
Options
• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 54.0 to 66.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 43.0 to 47.5
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 64.0 to 70.0
4 ― ― ― 4 Bushing 1 110.0 to 120.0
E-SUT06S3016F-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT06S3016F-PIPE-03 5 Steel pipe 1 247.0 to 286.0
6 Steel piping joint (elbow) 2 28.5 to 33.0 6 Steel piping joint (elbow) 2 95.0 to 110.0
7 Bushing 1 57.0 to 66.0 7 ― ― ―
8 Plug 1 95.0 to 110.0 8 Plug 1 95.0 to 110.0
9 Installation guide 1 ― 9 Installation guide 1 ―
IN VERT ER H Y D R A U L I C U N I T 46
● Piping set
9
Part Configuration 3 5
Mounted in the port at the back of the return filter
6 1
6
3
7 8
• For installing 02 size control systems • For installing 03 size control systems
Model code Name Quantity Tightening torque (N•m) Model code Name Quantity Tightening torque (N•m)
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 64.0 to 70.0 2 Hose adaptor (straight) 1 110.0 to 120.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
E-SUT06S6007F-PIPE-02 4 High-pressure bushing 1 110.0 to 120.0 4 ― ― ―
E-SUT06D4016F-PIPE-02 5 Steel pipe 1 100.0 to 120.0 E-SUT06S6007F-PIPE-03 5 Steel pipe 1 247.0 to 286.0
E-SUT06D6021F-PIPE-02 6 Steel piping joint (elbow) 2 28.5 to 33.0 E-SUT10D6021F-PIPE-03 6 Steel piping joint (elbow) 2 57.0 to 66.0
E-SUT10D6021F-PIPE-02 7 Low-pressure bushing 1 57.0 to 66.0 7 ― ― ―
8 ― ― ― 8 ― ― ―
9 Plug 1 95.0 to 110.0 9 Plug 1 95.0 to 110.0
10 Installation guide 1 ― 10 Installation guide 1 ―
1 Hydraulic hose 1 54.0 to 66.0 1 Hydraulic hose 1 108.0 to 132.0
2 Hose adaptor (straight) 1 43.0 to 47.5 2 Hose adaptor (straight) 1 110.0 to 120.0
3 Hose adaptor (elbow) 1 43.0 to 47.5 3 Hose adaptor (elbow) 1 110.0 to 120.0
4 High-pressure bushing 1 110.0 to 120.0 4 ― ― ―
E-SUT10S8007F-PIPE-02 E-SUT10S8007F-PIPE-03
5 Steel pipe 1 100.0 to 120.0 5 Steel pipe 1 247.0 to 286.0
E-SUT10D8021F-PIPE-02 E-SUT10D8021F-PIPE-03
E-SUT16D8021F-PIPE-02 6 Steel piping joint (elbow) 2 28.5 to 33.0 E-SUT16D8021F-PIPE-03 6 Steel piping joint (elbow) 2 57.0 to 66.0
7 Low-pressure bushing (small) 1 57.0 to 66.0 7 Bushing 1 114.0 to 132.0
8 Low-pressure bushing (large) 1 114.0 to 132.0 8 ― ― ―
9 Plug 1 142.5 to 165.0 9 Plug 1 142.5 to 165.0
10 Installation guide 1 ― 10 Installation guide 1 ―
Part Configuration 44 4
6 Mounted in the port at the back of the return filter
5
5
1
47 IN V E RT ER H Y D R A U LIC U N IT
(Separately available parts)
Options
IN VERT ER H Y D R A U L I C U N I T 48
Method of Selection
(1) Calculation of cylinder output (see the calculation formula for each load) F: Load (N)
Calculate the force F (N) required for the cylinder. A: Pressurized area of the
(2) Calculation of the required pressure (Pu) of the cylinder (Pu = F/A) cylinder (cm2)
* The pressurized area varies
Based on the force (F) and pressurized area (A), calculate the net pressure (Pu; MPa) depending on the specifications of
required for the cylinder. the hydraulic cylinder.
(4) Calculation of the net required discharge rate (Qc) of the cylinder (Qc = A × V × 0.06) V: Speed (cm/sec)
Based on the cylinder speed (V) and pressurized area (A), calculate the net discharge
rate (Qc; L/min) of the cylinder.
g1: Flow rate loss (L/min)
(5) Calculation of the required discharge rate (Qp) of the pump
Set the flow rate loss according
Add the flow rate loss to the net discharge rate (Qc) of the cylinder.
to (1) the pressure reducing
(6) Total required discharge rate (Qp) of the pump valve type, and (2) the pressure
Calculate the maximum required discharge rate of the pump by totaling the (Qp) values reducing valve diameter.
of the cylinders to be simultaneously operated.
3. Based on the maximum required pump pressure (Pp) and pump discharge rate (Qp), select the Super Unit size.
By referring to the "Pressure – Flow Rate Characteristics" charts (on Pages 13 and 14), select a model such that the Pp and
Qp values of all cylinders fall within the P-Q curve.
Fs = I1/I2 × W W
Load whose direction of force L1
C. Inverting load changes (+ → −) I2
θ
(Examples: down ender, I1 = L1 × cosθ θ
L2 I1
workpiece rotation) I2 = L2 × cosθ
Fs = W × µ
Load driven by positive sliding
Friction coefficient
D. Resistance force in both forward and
{
W
W
load backward operation Standard setting: 0.3
(Examples: pusher, table slide)
Other cases: user-defined value
Fs = W × µ
Load driven by large inertial
Friction coefficient
force in high-speed operation
E. Inertial load W
W
with a heavy object
(Example: Coil car travel) { Standard setting: 0.1
Other cases: user-defined value
49
Handling
The following are the minimum requirements for use of the Super Unit.
For details, refer to the unit’s Instruction Manual.
Ambient conditions
1. Ambient temperature: 0 to 40°C, ambient humidity: 85%RH maximum (with no condensation), altitude:
1,000 m maximum, to be used indoors
Hydraulic oil
1. Use general petroleum hydraulic oil (R&O) or wear-resistant hydraulic oil.
If use of hydrous or synthetic oil is intended, consult Daikin.
2. Use hydraulic oil equivalent to ISO VG32 to 68 and operate the unit within an oil viscosity range from 15 to 400 mm2/s
and a tank oil temperature from 0 to 60°C. The recommended operating range is from 15 to 50°C (20 to 200 mm2/s).
3. Keep contamination of hydraulic oil within NAS class 9, or NAS class 10 for 7 MPa or lower pressure.
3. Keep obstacles that will obstruct air intake and emission at least 100 mm away from the end face of the unit.
Install the unit at a location with good air flow so that heated air can be vented.
4. Use hoses for piping to provide flexibility.
5. Before operating the unit, be sure to remove the wing bolt and spacer for protecting the rubber vibration isolator.
If you fail to do so, the noise and vibration may be excessive.
6. Be sure to secure the space required to access the unit during electrical wiring at the noise filter box or control unit side.
Electric wiring
1. Install a no-fuse breaker and a ground fault interrupter compliant with European Standard EN60947-2 in the main
power supply of this hydraulic unit, to protect the electrical circuits against shorting and overcurrent, and to prevent
electric shocks.
2. Use suitable electric cable in accordance with the power supply capacity.
3. Be sure to provide a ground connection with a grounding resistance of 100 Ω maximum, and connect the grounding
wire directly with no breaker in the line.
4. Take care not to leave waste metal such as screws and cutting chips, combustible matter such as wood waste or oil,
or wiring debris inside the controller.
5. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit.
6. Before accessing the interior of the controller, turn the unit’s power supply OFF. Make sure that the circuit is turned
OFF using the circuit breaker for the primary power supply, and then wait at least 5 minutes.
Other precautions
1. If a failure occurs in the hydraulic unit, the system indicates an alarm and stops.
2. If failure or malfunction of this unit is expected to cause death or pose a danger to human beings, adopt appropriate
safety measures in the facilities. If this unit is used in an important facility, also adopt appropriate safety measures in
the facility to ensure that a failure of the equipment will not lead to a serious accident or loss.
Method of Selection
Handling
3. It takes approximately 3 seconds for this hydraulic unit to start up after being powered ON.
Depending on the piping conditions, the unit may take longer to increase the pressure to the pressure switch’s
preset level, resulting in pressure switch signal output. In this case, set the machine up so that it will not accept this
alarm output during this period.
4. Do not turn the power OFF/ON with the main power breaker frequently. It may damage controller components.
(Use the “run/stop” digital input signals for frequent power OFF/ON control.)
50
[Official] Introducing a Video Site
We have opened a site where you can watch videos on the latest
models of the DAIKIN Oil Hydraulics Division, including Super Unit,
EcoRich, and oil cooling units, all in one place.
Everything from the energy-saving technology supporting hybrid
products to the features and functions of each model is explained in The site is also ready
an easy-to-understand manner. for smartphones and
By registering the page in the favorites on your computer or cell tablets!
phone, you can find the latest information at your fingertips any time.
Daikin Hydraulic Search
URL https://www.daikinpmc.com/en/mv/index.html
Osaka Office
YODOGAWA PLANT
1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan
Phone: 81-6-6349-4475
Fax.: 81-6-6349-7862
Home Page: https://www.daikinpmc.com/en/
Contents in this catalog are subject to change for improvement without prior notice.