FEATURES

Figure 1: Field-of-View (Horizontal)


COLLECTION BY LEVITON
• Leviton's Decora® style design • Switches electronic ballasts
• Low Profile, tamper-resistant lens • Ambient Light Override 60 ft. (18.3 m)
Designer Wall Switch 30 ft. (9.1 m)
Occupancy Sensor INTRODUCTION

20 ft. (6.1 m)
Single Pole (One Location) Leviton Cat. No. ODS1Ø-IDx, Designer Wall Switch Occupancy Sensor, is designed to detect motion from a heat-emitting
or Multi-Location source (such as a person entering a room) within its field-of-view (monitored space) and automatically switch lights ON

40 ft. (12.2 m)
and OFF. The controlled lights will remain ON until no motion is detected and the scheduled time-delay has expired.
Rated: 120/277V, 60Hz Cat. No. ODS1Ø-IDx is UL listed, CSA certified and conforms to California Title 24 requirements.
Cat. No. ODS1Ø-IDx
DESCRIPTION
Incandescent The Occupancy Sensor senses motion within its coverage area of 2400 sq. ft. (223.3 m2) maximum and controls the
800W - 6.67A @ 120V connected lighting. This is a self-contained device which provides sensing and light control. The Occupancy Sensor will
turn the lights ON when motion is initially detected, and keep the lights ON for as long as motion is detected.
Fluorescent The Occupancy Sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. This
1200VA - 10A @ 120V Fresnel lens establishes dozens of zones of detection. The sensor is sensitive to the heat emitted by the human body. In
2700VA - 10A @ 277V order to trigger the sensor, the source of heat must move from one zone of detection to another. The device is most
effective in sensing motion across its field-of-view, and less effective sensing motion towards or away from its field-of- Figure 1A: Side (Vertical) Field-of-View
Supplemental view (refer to figures 1 and 1A). Keep this in mind when selecting the installation location (refer to figures 1 and 1A).
Sensor Unit
Note that occupancy sensors respond to rapid changes in temperature, so care should be taken not to mount the device
1/4hp - 5.8A @ 120V near a climate control source (i.e. radiators, air exchanges, and air conditioners). Hot or cold drafts will look like body
motion to the device and will trigger it if the unit is mounted too close. It is recommended to mount the Occupancy

(1.2 m)
8.3 0 10

4 ft.
No Minimum Load Required Sensor at least 6 ft. away from then climate control source. The device can be mounted in a single gang wallbox.
In addition, it is also recommended NOT to mount the Occupancy Sensor directly under a large light source. Large
Compatible with electronic and magnetic ballasts, 27 ft.

(1.4 m)
4.5 ft.
wattage bulbs (greater than 100W incandescent) give off a lot of heat and switching the bulb causes a temperature (8.2 m)
electronic and magnetic low-voltage ballasts, change that can be detected by the device. Mount the Occupancy Sensor at least 6 ft. away from large bulbs. If it 38 ft.
incandescent lamps, and fans. necessary to mount the device closer, lower the wattage of the bulb directly overhead. (11.7 m)

Installation Instructions FCC COMPLIANCE STATEMENT


Figure 2: Sensor Features
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
must not cause harmful interference, and (2) This device must accept any interference received, including interference Mounting Yoke
DI-000-ODS10-02A that may cause undesired operation.
Lens
INSTALLATION INSTRUCTIONS
LIMITED FIVE YEAR WARRANTY AND EXCLUSIONS WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND Blinders
Leviton warrants to the original consumer purchaser and not for REGULATIONS.
the benefit of anyone else that this product at the time of its sale
by Leviton is free of defects in materials and workmanship under WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED Control Panel
ELECTRICIAN. Cover
normal and proper use for five years from the purchase date.
Leviton’s only obligation is to correct such defects by repair or WARNING: CONTROLLING A LOAD IN EXCESS OF THE SPECIFIED RATINGS WILL DAMAGE THE UNIT AND
replacement, at its option, if within such five year period the POSE RISK OF FIRE, ELECTRIC SHOCK, PERSONAL INJURY OR DEATH. CHECK YOUR LOAD RATINGS TO
product is returned prepaid, with proof of purchase date, and a Push Button
DETERMINE SUITABILITY FOR YOUR APPLICATION. LED
description of the problem to Leviton Manufacturing Co., Inc., Window
Att: Quality Assurance Department, 59-25 Little Neck WARNING: DO NOT INSTALL THIS UNIT TO CONTROL A RECEPTACLE.
Parkway, Little Neck, New York 11362-2591. (In Canada send OTHER CAUTIONS AND NOTES:
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point
Claire, (Quebec), Canada, H9R 1E9). This warranty excludes 1. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING BULBS.
and there is disclaimed liability for labor for removal of this 2. USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY. WITH ALUMINUM WIRE, USE
product or reinstallation. This warranty is void if this product is Bottom
DEVICES MARKED CO/ALR OR CU/AL ONLY.
installed improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is not 3. DO NOT TOUCH THE SURFACE OF THE LENS. CLEAN OUTER SURFACE WITH A DAMP CLOTH ONLY.
used under normal operating conditions or not in accordance 4. THE CAT. NO. ODS1Ø-IDx OCCUPANCY SENSOR IS INTENDED TO REPLACE A STANDARD LIGHT SWITCH.
with any labels or instructions. There are no other or implied Figure 2A: Control Features
warranties of any kind, including merchantability and fitness for TO INSTALL:
Blinder
a particular purpose, but if any implied warranty is required by NOTE: Cat. No. ODS1Ø-IDx requires a ground connection in order to operate. Use the ground wire in the electrical box Adjustment
the applicable jurisdiction, the duration of any such implied for ground connection. If there is no ground wire, make sure the electrical box is grounded and attach the ground wire to Levers
warranty, including merchantability and fitness for a particular
purpose, is limited to five years. Leviton is not liable for incidental,
the box with a screw.
indirect, special, or consequential damages, including without 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST
limitation, damage to, or loss of use of, any equipment, lost sales THAT THE POWER IS OFF BEFORE WIRING.
or profits or delay or failure to perform this warranty obligation.
The remedies provided herein are the exclusive remedies under
2. Connect wires per appropriate WIRING DIAGRAM as follows (refer to wiring diagrams 1 & 2): BLACK lead to LINE.
this warranty, whether based on contract, tort or otherwise. BLUE lead to LOAD. GREEN lead to GROUND. Twist strands of each lead tightly and, with circuit conductors, push
1 2 4 7 4 7
firmly into the appropriate wire connector. Screw connector on clockwise making sure that no bare wire shows below
For Technical Assistance Call: the connector. Secure each wire connector with electrical tape. 3 10 10
Time Range Light
1-800-824-3005 (U.S.A. Only) 3. Carefully position the wires into the wallbox, then mount the Sensor Unit into the wallbox.
1 800 405-5320 (Canada Only)
www.leviton.com
4. Secure device using long mounting screws provided.
5. Restore power at circuit breaker or fuse.
NOTE: Allow approximately thirty (30) seconds after power is supplied for warm-up. After this, the device will
turn the lights ON and the LED will blink.
Slash Mark
DI-000-ODS10-02A
6. Perform the adjustments for the time-out and the light setting (refer to Time Delay and Ambient Light sections).
TROUBLESHOOTING GUIDE
If necessary, adjust the range control and the blinders to stop any unwanted activation of the lights.
NOTE: To avoid PERMANENT DAMAGE to the unit, be careful NOT TO OVERTURN the control knobs or levers when 1. If there is no response from the unit (the light never turns ON and the LED never blinks) 1 1/2 minutes after power is
setting Cat. No. ODS1Ø-IDx. The controls can be accessed by removing the wallplate and control panel cover. Use a applied, then uninstall device and verify there is a ground connection at the wallbox. If there is a ground connection,
small straight blade screwdriver to adjust knobs and a finger to adjust the blinder levers. verify wiring.
NOTE: DO NOT press in on blinder levers or use excessive force (refer to figures 2 & 2A). 2. If the lights never turn ON, but the LED blinks, check if the Ambient Light Control Knob is pointed fully counter-
clockwise (CCW). Rotate it clockwise (CW) until the lights turn ON.
7. Attach the Control Panel cover, and a Decora® Wallplate (not included). INSTALLATION IS COMPLETE. Leave the
room and the lights will turn OFF after the selected time-out expires. 3. If the lights constantly stay ON, even when the room is unoccupied:
A. Check the Time setting. See how this time compares to how long the lights stay ON.
FEATURES B. Try lowering the Range Control. Rotate the knob CCW about 30˚.
C. If the problem persists, try reducing again. Note: Do Not reduce so much that Cat. No. ODS1Ø-IDx cannot see
BLINDERS: The blinders can narrow the field-of-view of the device to prevent unwanted activation from traffic in adjacent normal occupancy.
space. There are two blinders, and each operate independently. To operate the blinders, use a finger or small screwdriver D. Be sure to use the Blinders to block any unwanted hallway traffic.
to move the blinder adjustment levers toward or away from the center of the device.
E. Check for reflected heat/motion as Sensor Unit may be seeing motion through a window.
The blinder levers are found above the control knobs and below the text ‘BLINDERS’ on the control panel. With both
levers moved fully towards the center, the field-of-view is narrowed to 32°. With both levers moved fully away from the F. Check for adjacent HVAC and/or heater ducts.
center, the field-of-view is at a maximum 180° (refer to figure 2A). 4. For additional information call Leviton’s Technical Support Line.
TIME-DELAY: Cat. No. ODS1Ø-IDx will turn lights ON when motion is detected. When motion is no longer detected, the
Sensor Unit will wait a certain amount of time and then turn the lights OFF. This wait time is called ‘time-out’.
The “time-out” is selected from four (4) preset values. Pointing the arrow at one of the markings on the face chooses the Wiring Diagram 1: Single Control Application
value of time. The following selections are available:
Face Marking Value of Time
(/) Slash Mark 30 second fixed time-out used for performing a walk-test. Sensor
1 10 minute time-out
2 20 minute time-out
3 30 minute time-out Blue
The “time-out” is factory preset to ten (10) minutes. Refer to figure 2A.
NOTE: All time durations mentioned in the instructions are approximate within 10 seconds. Black
Hot (Black)
AMBIENT LIGHT: The Ambient Light Level is the amount of light present in a room without any artificial light added. If
there is already enough light in a room, the occupant may not need further artificial light. Cat. No. ODS1Ø-IDx has an Black
adjustment to keep the lights from turning ON if there is enough light already present. The adjustment should be made Load
when the ambient light is at the level where artificial light is needed. Follow these steps to make a more accurate
Line
adjustment of the Light Control. 120/277VAC, 60Hz
Green White
AMBIENT LIGHT SETTING:
Ground
1. With the lights ON, rotate the Time Control fully counter-clockwise (CCW) to set the time-out to the thirty (30) second
test mode (refer to figure 2A).
2. Rotate the Light Control fully CCW.
Neutral (White)
3. Cover the Sensor Unit with an opaque material, or leave the room and let the Sensor Unit time-out and turn the lights
OFF.
4. Rotate the Light Control clockwise (CW) SLOWLY, until the light turns ON. This is the setting for the current level of
light in the room.
5. Adjustments are finished. Wiring Diagram 2: Two Location Control Application
Manual ON Mode: When the light control is in the fully CCW position the lights will never automatically turn ON. In this
mode the lights need to be manually turned ON by the push-button, and will turn OFF with the absence of motion.
If the light control is in the fully CW position, the lights will turn ON whenever motion is detected, even in full daylight.
Intermediate settings will cause the lights to turn ON only when the ambient light is below the level selected by the light Sensor Sensor
control.
NOTE: The ambient light in a room will change with the time of day and the season of the year.
RANGE: To decrease detection range and sensitivity, rotate the knob CCW (refer to figure 2A). The detection range can
be adjusted from 100% down to 36%.
Blue Blue Black
TO OPERATE Hot (Black) Black
PUSH-BUTTON: Cat. No. ODS10-IDx has a push-button switch that will toggle the lights (refer to figure 2). If the lights Black
are OFF, the lights will turn ON when the button is pressed, and remain ON in the presence of motion. In the absence of
motion, the Sensor Unit will time-out and turn the lights OFF. Load
Line
If the lights are ON, the lights will turn OFF when the button is pressed. The lights will stay OFF regardless of motion
detected, until the time-out expires. After the time-out expires, the lights will turn ON with the next detected motion. This 120/277VAC, 60Hz Green Green
is useful for slide or film presentations. Ground Ground
NOTES: White
• The Motion Indicator LED will blink every 2 seconds while motion is detected.
• In Manual-On mode, the button must be pressed to turn the lights ON. In the absence of motion, the unit will time-out
and turn the lights OFF.
• If Manual-On mode is desired, keep the Light knob in the fully counter-clockwise (CCW) position. Neutral (White)

NOTE: Either Sensor can turn the lights ON. Either Sensor must time-out to OFF, or both manual
buttons must be pressed for the lights to turn OFF.
DI-000-ODS10-02A
FOLD SCHEME
11.5¨

Front Panel

Cat. No.

8.5¨

LEVITON INSTRUCTION SHEET/MANUAL