ISO 9001, ISO1400, ISO13485, CE

and WHO-GMP certified.

Environmentally friendly blood bank refrigerator powered by Meditech Technology for safe agitation of Plasma bags.

Stable Temperature Control


Temperature is controlled by
two sensors located in the liquid-
loaded monitor bottles, which
are in the shape of a blood bag

Two thermistor sensors


constantly monitor the
temperature in both the upper
and the lower part of chamber.

Microprocessor control
ensures the most accurate
temperature control available.

Designed to conform to AABB criteria, User Friendly Design


the series ensures stable and reliable Selectable storage system Fluorescent
temperature control utilizing Meditech interior lamp with ON/OFF switch and a
original technology. A special highly
efficient compressor designed and used large view window in the outer door
by Meditech provides rapid cooling and provide a clear view of stored items
quiet performance for each model. Temperature-maintained defrost Alarm and Safety Functions
designed with thermal sensors and To ensure the safety of precious plasma
heaters in the evaporator, all under supply, the Meditech Series provides the
precise microprocessor control. following safety functions
Temperature Variations Prevented
Foamed-in-place insulation in the walls and magnetic sealed outer doors Audible and flashing LED visual alarms
with double-pane glass window prevent chamber air leakage and promote with remote alarm contacts, in case of
complete door closings power failure, high or low temperature
Large air circulation fan enables rapid temperature recovery after door Door Alarm and key lock are standard
openings features
FEATURES Built-in temperature recorder.
Digital temperature recorder controller unit coupled with a unique air flow system maintains the chamber uniformly at the
AABB recommended temperature of 22 +/- 0.1ºC.
Digital sensor placed inside the solution-filled bottle ensures error-free readings and matches the exact temperature inside the
bag.
Agitation at 70 +/- 5 cycles per minute to avoid platelet clumping and to ensure maximum viability.
SS304 grade sliding stainless steel trays.
Pause switch provided to arrest agitator motion for 10 seconds, for easy placement and removal of bags.
Toughened glass door for safety and better visibility of platelet bags.
Magnetic gaskets for doors ensure no air is lost in a „door closed‟ condition.
The internal fan switches off when the door is opened to avoid the loss of cold air.
Eyelevel positioning of TRCU for better visibility.
Automatic illumination when the door is opened allows for better visibility.
The stabilizer protects the incubator from input voltage fluctuations and ensures that the equipment has a long life-cycle

www.newmeditech.com 1
Know your machine

Equipment meets electrical safety specification such as that of IEC (ClassI)

CFC free refrigerant gas/green gas


The display is positioned at eye-level to CFC free insulation
make it easier to read and simplify operation.

Digital PLC Controller


External Corrosion Resistant, powder
coated (CR at least 1.2mm thickness)
Led Light along the length of the
Refrigerator for uniform illumination
through all the Compartment Refrigerator Body

Glass & Solid door, Automatic closing of Door Heater avoids moisture condensation in humid
the front door below opening angle of 90º atmospheric conditions. Pane heated glass door
and opening angle limited to insulates the refrigerator from atmospheric
110º.Insulation and gasket is of silicone temperature Magnetic door gaskets

Built In 7 Days circular


chart recorder
4 Castor Wheels, 2 Lockable
& 2 Movable Efficient compressor faster pull down & Recovery
Time. Compressor Starting Voltage: 22% below
nominal voltage.

Best in Class 80mm insulation for effective


Circulators for uniform Temperature
temperature Holdover

Hotline to prevent Internal Stainless steel (min.22g)


frost accumulation

An inbuilt line voltage corrector of appropriate


rating will form part of standard configuration.
Smart handle with
Lock and Key

Blood Storage Shelves . Mesh type


Factory calibrated digital sensor dipped in sliding stainless steel tray allows bags
liquid medium for accurate temp to be placed upright with sufficient
measurement and display .Flicker free LED airspace to reduce “Sardine effect”
lamp for uniform lighting and better

Unique design of Thermal barrier for


better energy efficiency
Door opening audio
and visual display alarm. USB Data Logger

Agitator

Removable Plates

Pause Button

www.newmeditech.com 2
Advance LED based PLC Based Controller

LED INDICATION
1. Line In
2. Power
3. Comp On
4. Heater On
5. Battery On
6. Battery Low
7. Temp High
8. Temp Low
9. Power Fail
10. Sensor Fail
11. Chart Change
12. System On
Scrolling LIVE Data logger on LED screen
1. Temperature User Friendly Settings
2. Incoming Voltage 1. Date
3. Ambient Temperature 2. Time
4. Time in hours of revolution chart 3. High Temp Alarm
5. Current Date 4. Low Temp Alarm
6. Current Time 5. Hysteresis
7. Battery Voltage 6. Compressor Delay

Temperature Recording
Model Bags, 350 ml Capacity Device
MTIA01 48 Bags 150 litres 7 days Chart recorder
Incubator- MTIA02 96 bags 275 litres 7 days Chart recorder
Agitator MTIA12A 130 Bags 330 Litres 7 days Chart recorder
MTIA03 168 bags 500 Litres 7 days Chart recorder

www.newmeditech.com 3
6.0 LED Indicators

Sl.No Photos Function Indication


1. This LED is on when there is a power supply to the
machine from the main source

2 This LED is on when theController is in working


condition.

3 This LED is on when the compressor is in working


condition

4 This LED is on when the heater is in working


condition

5 This LED is on when the battery is in working


condition

6 This LED is on when the battery is discharged

7 This LED is on when the inside compartment


temperature of the refrigerator is high above the set temp

8 This LED is on when the inside compartment


temperature of the refrigerator is Low below the set temp

9 This LED is on when there is power failure.

10 This LED is on when there is sensor fail

11 This LED is on when after 162 hours of charge


change ( 6 hours before the completion of 7 days)

12 This LED is on when all functions of the System is


in working condition

www.newmeditech.com 4
7.0 Keypad Functions

Sl.No Photos Function Indication


1 The Menu button is pressed to enter into MENU
option.

2 The Enter button is pressed to enter into “ENTER”


option.

3 The Up Arrow button is pressed to go Upwards in


the menu option.

4 The Down Arrow button is pressed to go


Downwards in the menu option.

5 The data logger is pressed to get the data from the


PLC to the computer

6 The MUTE button is pressed to MUTE any Alarms


and sounds

7 The Door Open LED is activated along with the


buzzer sound indicating the Door Open function

8 The ON button is pressed to switch on the


refrigerator

9 The USB is provided to connect the Refrigerator to


the computer system.

www.newmeditech.com 5
Touch Screen LCD Controller

www.newmeditech.com 6
ISO 9001, ISO1400, ISO13485, CE
and WHO-GMP certified.

TOUCH SCREEN FUNCTIONS

INVENTORY: Now maintain inventory of


Blood Groups Electronically. No need of
bulky registers and manual confusion.
Meditech Helps to maintain Blood groups
row wise , tray wise and partition wise so that
the touch screen always displays the current
stock in Refrigerator. Also Meditech screen
displays blood stock group wise such as A,
A+, B+, B-, AB+, AB-, O+ and O-

SCADA software is also available for full


Blood Bank management system.

ALARMS: Low Temperature and high


temperature alarms history and graphs can be
viewed or printed or transferred using PEN
drive.

USB: USB Menu helps to transfer all logs to


a flash PEN Drive

TRENDS: This Menu displays higher and


lower temperature parameters with time in
Historical and Real Time.

CALENDAR: Time and Date can be set


using this MENU

SMS: This MENU is set to sent SMS of all


critical parameters to a predefined number

IO STATUS: This MENU is used at the time


of trouble shooting

USER LOGIN: Keep you Refrigerator and


data protected with passwords. User are
created using this MENU

www.newmeditech.com 7