ISO 9001, ISO1400, ISO13485, CE
and WHO-GMP certified.
Environmentally friendly blood bank refrigerator powered by Meditech Technology for safe agitation of Plasma bags.
 Stable Temperature Control
 Temperature is controlled by
 two sensors located in the liquid-
 loaded monitor bottles, which
 are in the shape of a blood bag
 Two       thermistor     sensors
 constantly      monitor      the
 temperature in both the upper
 and the lower part of chamber.
 Microprocessor           control
 ensures the most accurate
 temperature control available.
Designed to conform to AABB criteria,                                             User Friendly Design
the series ensures stable and reliable                                            Selectable storage system Fluorescent
temperature control utilizing Meditech                                            interior lamp with ON/OFF switch and a
original technology. A special highly
efficient compressor designed and used                                            large view window in the outer door
by Meditech provides rapid cooling and                                            provide a clear view of stored items
quiet performance for each model.        Temperature-maintained defrost            Alarm and Safety Functions
                                         designed with thermal sensors and         To ensure the safety of precious plasma
                                         heaters in the evaporator, all under      supply, the Meditech Series provides the
                                         precise microprocessor control.           following safety functions
Temperature Variations Prevented
Foamed-in-place insulation in the walls and magnetic sealed outer doors            Audible and flashing LED visual alarms
with double-pane glass window prevent chamber air leakage and promote              with remote alarm contacts, in case of
complete door closings                                                             power failure, high or low temperature
Large air circulation fan enables rapid temperature recovery after door            Door Alarm and key lock are standard
openings                                                                           features
FEATURES                                                                           Built-in temperature recorder.
Digital temperature recorder controller unit coupled with a unique air flow system maintains the chamber uniformly at the
AABB recommended temperature of 22 +/- 0.1ºC.
Digital sensor placed inside the solution-filled bottle ensures error-free readings and matches the exact temperature inside the
bag.
Agitation at 70 +/- 5 cycles per minute to avoid platelet clumping and to ensure maximum viability.
SS304 grade sliding stainless steel trays.
Pause switch provided to arrest agitator motion for 10 seconds, for easy placement and removal of bags.
Toughened glass door for safety and better visibility of platelet bags.
Magnetic gaskets for doors ensure no air is lost in a „door closed‟ condition.
The internal fan switches off when the door is opened to avoid the loss of cold air.
Eyelevel positioning of TRCU for better visibility.
Automatic illumination when the door is opened allows for better visibility.
The stabilizer protects the incubator from input voltage fluctuations and ensures that the equipment has a long life-cycle
                                    www.newmeditech.com                                                                    1
    Know your machine
  Equipment meets electrical safety specification such as that of IEC (ClassI)
                                                                                            CFC free refrigerant gas/green gas
  The display is positioned at eye-level to                                                 CFC free insulation
  make it easier to read and simplify operation.
   Digital PLC Controller
                                                                                                 External Corrosion Resistant, powder
                                                                                                 coated (CR at least 1.2mm thickness)
  Led Light along the length of the
  Refrigerator for uniform illumination
  through all the Compartment                                                                Refrigerator Body
  Glass & Solid door, Automatic closing of                                        Door Heater avoids moisture condensation in humid
  the front door below opening angle of 90º                                       atmospheric conditions. Pane heated glass door
  and opening angle limited to                                                    insulates the refrigerator from atmospheric
  110º.Insulation and gasket is of silicone                                       temperature Magnetic door gaskets
                                                                                    Built In 7 Days circular
                                                                                    chart recorder
    4 Castor Wheels, 2 Lockable
    & 2 Movable                                                                  Efficient compressor faster pull down & Recovery
                                                                                 Time. Compressor Starting Voltage: 22% below
                                                                                 nominal voltage.
 Best in Class 80mm insulation for effective
                                                                                 Circulators for uniform Temperature
 temperature Holdover
 Hotline to prevent                                                                                  Internal Stainless steel (min.22g)
 frost accumulation
An inbuilt line voltage corrector of appropriate
rating will form part of standard configuration.
                                                                                                                    Smart handle with
                                                                                                                    Lock and Key
                                                                                                Blood Storage Shelves . Mesh type
Factory calibrated digital sensor dipped in                                                     sliding stainless steel tray allows bags
liquid medium for accurate temp                                                                 to be placed upright with sufficient
measurement and display .Flicker free LED                                                       airspace to reduce “Sardine effect”
lamp for uniform lighting and better
                                                                                                  Unique design of Thermal barrier for
                                                                                                  better energy efficiency
             Door opening audio
             and visual display alarm.                                             USB Data Logger
                                                                                          Agitator
                                                                                            Removable Plates
                                                                                            Pause Button
                                                   www.newmeditech.com                                                             2
Advance LED based PLC Based Controller
                                                               LED INDICATION
                                                               1. Line In
                                                               2. Power
                                                               3. Comp On
                                                               4. Heater On
                                                               5. Battery On
                                                               6. Battery Low
                                                               7. Temp High
                                                               8. Temp Low
                                                               9. Power Fail
                                                               10. Sensor Fail
                                                               11. Chart Change
                                                               12. System On
         Scrolling LIVE Data logger on LED screen
   1.   Temperature                                            User Friendly Settings
   2.   Incoming Voltage                                       1. Date
   3.   Ambient Temperature                                    2. Time
   4.   Time in hours of revolution chart                      3. High Temp Alarm
   5.   Current Date                                           4. Low Temp Alarm
   6.   Current Time                                           5. Hysteresis
   7.   Battery Voltage                                        6. Compressor Delay
                                                           Temperature Recording
                   Model       Bags, 350 ml   Capacity     Device
                   MTIA01      48 Bags        150 litres   7 days Chart recorder
   Incubator-      MTIA02      96 bags        275 litres   7 days Chart recorder
   Agitator        MTIA12A     130 Bags       330 Litres   7 days Chart recorder
                   MTIA03      168 bags       500 Litres   7 days Chart recorder
                           www.newmeditech.com                                          3
6.0 LED Indicators
Sl.No   Photos                    Function Indication
1.                                This LED is on when there is a power supply to the
                                  machine from the main source
2                                 This LED is on when theController is in working
                                  condition.
3                                 This LED is on when the compressor is in working
                                  condition
4                                 This LED is on when the heater is in working
                                  condition
5                                 This LED is on when the battery is in working
                                  condition
6                                 This LED is on when the battery is discharged
7                                 This LED is on when the inside compartment
                                  temperature of the refrigerator is high above the set temp
8                                 This LED is on when the inside compartment
                                  temperature of the refrigerator is Low below the set temp
9                                 This LED is on when there is power failure.
10                                This LED is on when there is sensor fail
11                                This LED is on when after 162 hours of charge
                                  change ( 6 hours before the completion of 7 days)
12                                This LED is on when all functions of the System is
                                  in working condition
                 www.newmeditech.com                                                       4
7.0 Keypad Functions
 Sl.No   Photos                   Function Indication
 1                                The Menu button is pressed to enter into MENU
                                  option.
 2                                The Enter button is pressed to enter into “ENTER”
                                  option.
 3                                The Up Arrow button is pressed to go Upwards in
                                  the menu option.
 4                                The Down Arrow button is pressed to go
                                  Downwards in the menu option.
 5                                The data logger is pressed to get the data from the
                                  PLC to the computer
 6                                The MUTE button is pressed to MUTE any Alarms
                                  and sounds
 7                                The Door Open LED is activated along with the
                                  buzzer sound indicating the Door Open function
 8                                The ON button is pressed to switch on the
                                  refrigerator
 9                                The USB is provided to connect the Refrigerator to
                                  the computer system.
                  www.newmeditech.com                                                   5
Touch Screen LCD Controller
            www.newmeditech.com   6
                                         ISO 9001, ISO1400, ISO13485, CE
                                         and WHO-GMP certified.
TOUCH SCREEN FUNCTIONS
                                       INVENTORY: Now maintain inventory of
                                       Blood Groups Electronically. No need of
                                       bulky registers and manual confusion.
                                       Meditech Helps to maintain Blood groups
                                       row wise , tray wise and partition wise so that
                                       the touch screen always displays the current
                                       stock in Refrigerator. Also Meditech screen
                                       displays blood stock group wise such as A,
                                       A+, B+, B-, AB+, AB-, O+ and O-
                                       SCADA software is also available for full
                                       Blood Bank management system.
                                       ALARMS: Low Temperature and high
                                       temperature alarms history and graphs can be
                                       viewed or printed or transferred using PEN
                                       drive.
                                       USB: USB Menu helps to transfer all logs to
                                       a flash PEN Drive
                                       TRENDS: This Menu displays higher and
                                       lower temperature parameters with time in
                                       Historical and Real Time.
                                       CALENDAR: Time and Date can be set
                                       using this MENU
                                       SMS: This MENU is set to sent SMS of all
                                       critical parameters to a predefined number
                                       IO STATUS: This MENU is used at the time
                                       of trouble shooting
                                       USER LOGIN: Keep you Refrigerator and
                                       data protected with passwords. User are
                                       created using this MENU
                 www.newmeditech.com                                               7