Bedroom Edge Unit D2

Uploaded by

alnoel tordilla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views1 page

Bedroom Edge Unit D2

Uploaded by

alnoel tordilla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Chino Roces Avenue, Makati City

X9 Y23 Y22
5150 2750
1200 125 350 3850 150
650 550 500 3700 500 1900 100 2450 500 2275 175
891 1790 900
950 950 1225 1225
895 895
7th Floor 7th Floor LEGEND
20600 20600
SYMBOLS: WALL TYPES :

550
D
DOOR NO. DOOR SCHEDULE
A 100MM THK. CHB

W
WI NDOW NO. WINDOW SCHEDULE B 150MM THK. CHB
10 Retails + On Site Parking @ Ground Floor, 3 Podium Parking,
FF - Amenity @ 5th Floor, and 3 Residential Towers with 29 Storeys
IN TERMEDIATE BEAM C 100MM THK . EPS
2850

2850

2850
FLOOR
FIN. NO. SA NDWICH PA NEL

2675
D
WALL FINISH

2300

2300
150MM THK . EPS
WA LL FIN ISH SCHEDULE

2150
WALL TY PE
SA NDWICH PA NEL

FLOOR ELEVA TION E PRECAST CON CRETE

1400
1300
DEP

615 200 160 200


HT
FLOO R DEPRESSION F 100MM THK. DRY WA LL

CE ILING FIN.
CEILING FINISH G REYNALDO C. MADRIDEJOS

300
RC WALL/COLUMN
300

300
CE ILING HT SCHEDULE
6th Floor 6th Floor TSD Officer- Circuit OpCen

17750 17750 LIGHTING SYMBOLS: WALL FINISHES :


WF - 3
COMPA CT FLOURE-
a SCENT LAMP(CFL)
PAIN TED CONCRETE FINISH
RAFAEL ANGELO H. RONCALE ANGELO M. OLITOQUIT
TSD Junior Officer TSD Junior Officer
WF - 7 300MMX300MM CERAMIC TILES
CFL CON NECTED TO UP TO 1500MM FROM FFL, REST
a( E) EMERGENCY POWER SUPPLY PLA STERED FINISH

WF - 8
300MMX300MM CERAMIC TILES 1
RECEPTACLE LAYER FROM FFL ,REST PLA STERED
REC FINISH JESSALIE ELISA MARIE A. CRUZ
TSD Supervisor
S SWITCH WF - 9 DRY WA LL SYSTEM
PAIN TED FINISH
TYP.1-BEDROOM EDGE UNIT TYP.1-BEDROOM EDGE UNIT
@1ST-28TH RES'L LEVEL @1ST-28TH RES'L LEVEL FLOOR FINISHES: ELECTRICAL SYMBOL:
ARISTOTLE N. SANTOS NEIL CHRISTIAN M. REYES
B1 ELEVATION A B2 ELEVATION B FF - 8 300MMX300MM NON SKID
CERA MIC TILES
CON VINIENCE OUTLET (C.O ) TSD Coordinator (AR/ ST) TSD Coordinator (MEPFS)

AR-701.1 SCALE : A1 - 1:50 AR-701.1 SCALE : A1 - 1:50 FF - 11


196MMX1200MM X 8MM THK C.O CON NECTED TO EMERGENCY Drawn by: Author Checked by: Checker
LAMINATED WOOD FLO ORING POWER SUPPLY
(E)
A3 - 1:100 A3 - 1:100 GENERAL NOTES:
CEILING FINISHES: REF REFRIGIRATOR C.O
Specialty Subcontractor to submit coordinated shop drawings showing detailed intent
C- 1 12MM THK GYPSUM BOARD ON
on how to fabricate, install, terminate; verify and indicate in shop drawings elevation,
SUSPENDED CEILING SY STEM, RANGE C.O
HT PAIN TED FINISH
R dimension, orientation, connection details, clearances, coordinated with other trade
contractors for proper constructability prior to any fabrication or installation to
C-3 10MM THK MO ISTURE RESISTANT
GYPSUM BOARD ON SUSPENDED
WA SHER/ DRYER C.O
achiev e Architectural, Interior Design, Landscape, Structural and Electro-Mechanical
HT CEILING SYSTEM, PAIN TED FINISH WD
design intent of the project. Advise MDC COG and TSD accordingly and promptly in
C-5 writing on conflict or lacking information in order to meet the Designers intent and
PLA IN RUBBED CONCRETE,
HT PAIN TED FINISH ACCO
WINDOW TYPE A IRCON C.O
Project Requirements as specified in the contract documents, issued plans and
specifications. For any alteration, Subcontractor to submit proposal indicating all
FIRE PROTECTION SYMBOL: U RANGE HO OD UTILITY BOX details duly coordinated with other trade contractors clearly specifying proposed
changes for Consultants approval prior to commencement of the work.
PENDEN T SPRIN KLER HEAD
U WA TER HEATER UTILITY BOX
WH For Designers standard details and specifications, please refer to issued FCD. RED
LINING must be reflected in IFC drawings for actual site changes and submitted to
UPRIGHT SPRIN KLER HEAD CA TV OUTLET TSD as a requirement for Billing Clearance.

For finish ceiling clearance height, please refer to the Arch'l Schedule of Finishes from
SIDE THROW SPRINKLER HEAD TELEPHONE OUTLET Visionary Architecture. Should there be any conflict or problem achiev ing the
headroom clearances, please inform MDC Operations and TSD for proper resolution
MECHANICAL SYMBOL : PANEL BOA RD prior to any commencement of the work.

WAC
For any inconsistency/ discrepancy/ revision/ changes/ alteration of IFC plans due to
WINDOW TYPE A IR H HEAT DETECTOR
CONDITIONIN G site condition/ construction methodology and strategy. Kindly inform the MDC-TSD for
proper coordination and documentation.
S SMOKE DETECTOR
EXHAUST STUB OUT
REVISION:
Y22 Y23 EXHAUST FAN A
FIRE ANNUNCIATOR
No. Description Date
X9 2750 5150 VEN T CAP

3850 350 295 2155 500 2450 100 1900 500 EXHAUST DUCT LINE

300MMX300MM
HA ND HOLE
900 895 895 891 1077 1077 1225 1225 950 950

7th Floor 7th Floor 200 175 175


20600 20600
SLAB SOFFIT LINE SLAB SOFFIT LINE SLAB SOFFIT LINE

200

200
350
BEAM SOFFIT LINE BEAM SOFFIT LINE
BEAM SOFFIT LINE
BULKHEAD(C)
BULKHEAD(B) (1-DUCT)
(1-DUCT) 200MM OR SAME DEPTH
BULKHEAD(A) 200MM OR SAME AS ADJACENT BEAM
2850

2850

(2-DUCT) DEPTH *USE IF ONLY WATER SUPPLY OR FIRE


2675

2675
350MM OR SAME DEPTH AS ADJACENT PROTECTION LINE WILL PASS THRU
2300

2300

AS ADJACENT BEAM BEAM BULKHEAD


2150

2150
1550
1300

IF 150MM Ø600 IF 150 MM Ø 600


IF 100MM Ø400 IF 100MM Ø 400
750

BEAM DEPTH

BEAM DEPTH
VERIFY

VERIFY
300

6th Floor 6th Floor


17750 17750

PART OF
PART OF PART OF UNIT B
PART OF
UNIT A 75150 150 75 UNIT B 75150 150 150 15075
UNIT A
375 375
BULKHEAD(D)
SAME DEPTH BULKHEAD(E)
AS PARALLEL/ ADJACENT BEAM WITH OUT BEAM

TYP.1-BEDROOM EDGE UNIT TYP.1-BEDROOM EDGE UNIT


@1ST-28TH RES'L LEVEL

ELEVATION C
@1ST-28TH RES'L LEVEL

ELEVATION D NOTES : N
B3 B4
AR-701.1 SCALE : A1 - 1:50 AR-701.1 SCALE : A1 - 1:50
A3 - 1:100 A3 - 1:100
1. ASTERISK (*) INDICATES UNIT AS MIRROR OF LAY OUT SHOWN
2. IDENTIFY "MAX"= BASE THE HT ON BEAM/GIRDER SOFFIT DEPTH
KEYPLAN
3. COLUMNS TAPER AS FLOOR LEVEL INCREASES.
4. LIGHT SWITCH MUST BE ALIGNED TO ANY ADJACENT CONVINIENCE OUTLET
5. IN CASE PANEL BOARDS,SWITCHES &/ OR OUTLETS ARE ON OPPOSITE SIDE OF
APPROVED BY:
A WALL,ONE SIDE MUST BE ADJUSTED TO AVOID CONFLICT BETWEEN UTILITY
BOXES (SUBMIT CSD FOR APPROVAL)
6. SOAP HOLDER,TISSUE PAPER HOLDER, FLOOR DRIAN&FLOOR CLEAN OUT
MUST BE ALLIGNED TO A TILE EDGE.
7. ACTUAL UNIT DIMENSIONS SHALL BE VERIFIED WITH MAIN FLOOR PLAN
8. MAIN DOOR FLOOR FINISH STARTING POINT SHOULD BE IN BETWEEN MAIN
DOOR PANEL THICKNESS (SEE MISCELLANEOUS DETAILS) ROCHELLE MARIE M. BALUYOT KRISTINE THERESE G. HORTINELA
9. VERIFIY STRUCTURAL FOR BEAMS &GIRDERS SIZES. Design Manager MDC DID-CG Project Architect MDC DID-CG
10. FOR LOCATION OF
OUTLETS,SWITCHES,PANELBOARDS,SPRINKLERS,HEAT/SMOKE DETECTOR,
EXHAUST FANS.STUB OUTS &ALL OTHER UTILITY APPARATUS,REFER TO THIS DETAIL.
11. VERIFIY STRUCTURAL DETAIL FOR EXHAUST DUCT PENTRATION THROUGH BEAM
LEGEND PROVIDE SHOP DRAWING.
12. SEE MISCELLANEOUS DETAIL FOR THE STANDARD MOUNTING HEIGHT
MARK ANTHONY S. NAVARRO
50 MM Project Officer MDC CMG - Avida
COLUMN ON GOING RFA/ WAO THICKNESS REFERENCES FOR BATHROOM FIXTURES, ELECTRICAL&ELECTRONICS PROVISIONS
FLOOR DEPPRESSION 1 125 COLUMN DIMENSIONS

1PS-1
T1C-1(700x1200)
DEP REVISION NUMBER REVISION SLAB (WxD) COLUMN 13. FOR ACCU FCU CONNECTION LINE,CONSIDER PIPE SLEEVES AS NECESSARY
REFERENCE SLAB MARK
SHEARWALL UPDATED/ RESOLVED ISSUES REVISION CLOUD CLOUD ELEVATION -50 COLUMN MARK
:VERIFY STRUCTURAL AND MECHANICAL FOR DETAILS.

INTERMEDIATE BEAM ON GOING RFI CUTTING PLANE REYNARD D. MARANAN JESUS S. ANIANO JR.
1 SECTION NAME SECTION 1PG-1(500x700) BEAM DIMENSIONS
(WxD) BEAM Project Director MDC CMG - Avida Project Director MDC CMG - Avida
GIRDER SHAFT/ CHASE AR-101 SHEET NUMBER CUTTING BEAM MARK

DESIGN AND BUILD: ARCHITECTURAL CONSULTANT: STRUCTURAL CONSULTANT: MECHANICAL CONSULTANT: FIRE PROTECTION CONSULTANT: ELEVATOR CONSULTANT: OWNER/DEVELOPER: SHEET CONTENTS: SHEET NO: ISSUE:

Unit 504 Pryce Center, 1179 Chino Roces Avenu e cor.


TYP. 1 BEDROOM EDGE UNIT ELEVATIONS ISSUED FOR
AR-701.1
CONSTRUCTION
Bagtican St., Mak ati City Basement-1, Makati Cin ema Square, Pasong Tamo St ., Makati City
Tel nos. 811-1777 / 811-1778 e-mail: nbf@globelines.com.ph
Telephone No. 896-97-04 to 05 Fax no. 896-97-60 to 61
e-mail address: arominsy@info.com.ph Fax no. 844-3667

LANDSCAPE CONSULTANT: ELECTRICAL CONSULTANT: PLUMBING CONSULTANT: DRAINAGE CONSULTANT: QUANTITY SURVEYOR:
DATE:
MAKATI DEVELOPMENT CORPORATION REVISION NO: PROJECT CODE: ATMS- AR
#909 40th Street North, Bonifacio Triangle
31st St. cor 2nd Ave. 1/F Bonifacio Technology Center, Basement-1, Makati Cin ema Square, Pasong Tamo St ., Makati City Basement-1, Makati Cin ema Square, Pasong Tamo St ., Makati City RFA REFERENCE NO: RFA DATE ISSUED: DATE APPROVED:
Bonifacio Global City, Taguig, Philippines 1630
Tel nos. 811-1777 / 811-1778 e-mail: nbf@globelines.com.ph Tel nos. 811-1777 / 811-1778 e-mail: nbf@globelines.com.ph Bonifacio Global City, 1634 Taguig City
Fax no. 844-3667 Fax no. 844-3667 SCALE: As indicated