MUST 30-120

3 Phase Modular
UPS

Finally the benefits of Modular ups are for all


MUST 30-120
The MUST 30/120 is an uninteruptible
power supply, three phase input/
output, ranging from 15 kVA to 120 kVA
(equipped with 15 kVA UPS modules), a
double conversion system, provided of
DSP technology, designed to work for
redundant applications (N+1).

Each module is a complete and independent UPS:

• Three phase rectifier


• Battery charger
• IGBT inverter
• Static switch
• DSP control logic

A very powerfull DSP of last generation.


That reduces the number of the external
components
SYSTEM ADVANTAGES
1. Highest reliability ( MTBF of the suppling chain 100 times more than the stand alone UPS)

2. Replacement of the fault module, with no supply interruption, (Hot swap)

3. Time to replace the module < 3 min

4. Power increasing simply by adding a module unit

5. Very low maintenance costs

6. Each module is a complete and independent Uninteruptible Power Supply

UPS FRONt PANEL

MENù:
1. System on
2. System stand-by
3. Temperature
4. Command
5. History
6. Diagnostic
7. Configuartion

The highest class performances to supply the most critical loads

• LOCAL AREA NETWORKS (LAN) • HOSPITAL • MILITAR APPLICATION


• SERVERS • BANKS • Industrial PLC
• INTERNET CENTERS (ISP/ASP/POP) • EMERGENCY DEVICES • ALARM SYSTEM
• DATA CENTERS • TELECOMMUNICATIONS DEVICES • TRANSPORTATION
The MUST system
1. MINI MUST 30
MINI MUST is the Entry Level to the MUST Family. It is the ideal solution to supply
a medium load that requires the redundancy or the possibility to expand the
power in the future. Its advantages win against any stand alone ups solution.
The solution is very compact and with the possibility to expand also the autonomy
adding up to 3 battery banks in the same cabinet. Power ranging from 15 kVA
to 30 kva (2 modules), 19’’ rack mounted with the internal battery pack.

mini MUST 30 kVA

2. MUST 60
Modular UPS three phase system ranging from 15 kva to 60 kva, 19’’ rack
mounted with the internal battery pack. This solution can include 4 modules
15 kva providing the following back up time at 75% of nominal load.

Max back up time with internal battery pack


Nr power kW at 75% of backup time
kVA
modules the rated load (min)

1 15 9 75
2 30 18 32
3 45 27 16
4 60 36 12
MUST 60 kVA
If redundancy is requested (N+1 modules) the max output power will be
45 kVA

3. MUST 120
Modular UPS three phase system ranging from 15 kVA to 120 kVA, 19’’
rack mounted, designed for external battery cabinet. The max output
power of the MUST cabinet is 120 kVA ( 8 modules 15 kVA/each).
The battery pack are included in the external cabinet. If redundancy is
requested ( N+1 modules) the max output power is 105 kVA.

MUST 120 kVA


4. Modular battery cabinet (2000x1000x800 HxDxW)
It is designed to include up to 40 x 100 Ah battery blocks. This battery
pack, with a 75% of the max load, allows a standard autonomy of 20
minutes. Longer back up time is possible simply adding battery cabinets,
working in parallel or using other battery packs in shelves.

battery cabinet

User interface
Communication board RS 232, RS 485 => STANDARD

Remote UPS monitoring for alarms, status, measures, historical data.

Communication board SNMP, relay card => OPTIONAL

SNMP Board
Free contacts circuit board
Pin # Description I/O
1 UPS Fail Output
UPS FAIL 1 2 Summary Alarm Output
6 BYPASS
3 GND Input
SUMMARY ALARM 2
7 BATTERY LOW 1 Remote Input
3
Shutdown
GND
8 UPS ON 5 Common Input
REMOTE SHUTDOWN 4 6 Bypass Output
9 LINE LOSS
7 Battery Low Output
COMMON
5
8 UPS ON Output
9 Line Loss Output

Communication interface card AS 400/dry


contact.
A very Complete Communication

WinPower Manager UPS Control Parameters

Event Log Shutdown Parameters


MUST 30-120
TECHNICAL SPECIFICATIONS
Model MUST 30-120
Nominal power from 15kVA to 120kVA
INPUT
Voltage 380V/400V/415V, 3 phases 4 wires
Voltage tolerance 294Vac to 520Vac
Frequency 50/60 ± 4Hz
Power Factor ≥ 0.99
THDi % < 5%
BYPASS
Voltage 380V/400V/415V, 3 phases 4 wires
Voltage tolerance 305Vac to 457Vac (selectable)
OUTPUT
Voltage 380V/400V/415V, 3 phases 4 wires
Static voltage stability ≤ 1.5%
Frequency 50Hz / 60Hz ± 0,05% (battery)
Power factor 0,8
Load < 105% no transfer to bypass; 105% ≤ load < 115% transfer to bypass
Overload protection after 5 min; 115% ≤ load < 125% transfer to bypass after 1 min; load ≥ 125 %
transfer after 1 sec.
Module
Nominal power 15kVA / 12kW
Efficency > 91% at full load
BATTERY
Battery nominal voltage 480 Vcc
Battery connections 3 wires (positive / neutral / negative)
Charger output voltage 273 ± 1% Vdc
Type VRLA sealed
Max load current 4,5A for each module (selectable by LCD display)
MECHANICAL
Acustical Noise (at 1 mt from the
≤ 62dB
UPS with 8 modules)
Ambient operative temperature 0°C - 40°C
Relative umidity (Max) 90% (non condensing)
Ambient store temperature -15°C - +55°C
Module weight 35kg
Module dimensions (mm) 440(W) x 700(D) x 131(H)
Mini Must Dimension (mm) 600(W) x 1000(D) x 1500(H)
Cabinet Dimensions / Must 60 (mm) 600(W) x 1000(D) x 2000(H)
Cabinet Dimensions / Must 120 (mm) 600(W) x 1000(D) x 2000(H)
STANDARD NORMS
Safety EN50091-1-1/EN62040-1-1
IEC 61000-4-2(L3); IEC 610004-3(L3); IEC 61000-4-4(L3);
Emc
IEC 61000-4-5(L4); EN 50091-2(>25A) Class A
Note: UPS specification and data may subject to change for improvement without prior notice
G-Tec Asia Pacific Pte Ltd
60 Kaki Bukit Place, #02-05, Eunos Techpark II, Singapore 415979
Tel. +65 6555.5014 - Fax +65 6555.4105
info@gtec.com.sg

G-Tec Europe srl


Strada Marosticana, 81/13 - 36031 Povolaro (VI), Italia
Tel. +39 0444.592463 - Fax +39 0444.365191
info@gtec-power.eu

www.gtec-power.eu

You might also like