Part A: Attaching the discharge tubing to the top stem
on the solenoid
1 Unscrew the top
discharge valve nut
2 Insert the rigid opaque
tubing through the nut.
and remove the red
protective cap.
PKX FT/A Quick Start Guide
Flow Rate 0.26 GPH, Max. Pressure 72 PSI
Discharge
Air Bleed Valve
Valve 3 Install the hose onto the
discharge barb making
4 Hand tighten the
discharge valve nut.
sure the hose is seated
up to the threads.
Priming
Barb
Suction
Valve
Included in the Box
5 Remove the nut off of 6 Insert the injection stem
the injection stem and into the water line as
• PKX FT/A Pump set aside. shown below. Use Teflon
• Bracket mounting kit for wall or foot mount tape on both threaded
• Operating instructions and maintenance manual connections.
• Pre-wired plug with blue wire
• Reducer fitting 1/2” MPT to 3/8” FPT 3/8” Injection
• Allen Wrench (to remove solenoid head if needed) Stem
• Contact plug for priming
• Hose packet
- Opaque, rigid PE tubing for the discharge 1/2” MPT to 3/8”
- Clear, flexible, PVC suction tube FPT Reducer
- Injection stem
- Foot filter
7 Insert the other end of
the opaque tubing
through the injection
stem nut, and attach the
tubing to the injection 8 Hand tighten the nut
onto the top of the
valve barb, push all the
way down to the threads. injection stem.
PKX FT/A
Installation
NOTE: Installation
illustrations are to be
used as a reference
guide only.
PKX
(See back for Part B and C)
Part B: Attaching the suction valve tubing
1 Cut the clear PVC flexible
tubing into two pieces the
2 Unscrew the suction valve
nut and remove the red
3 Insert the tubing through
the nut.
4 Install the suction tube
onto the barb, push all
correct size for your protective cap. the way to the threads.
application.
5 Then hand tighten the
suction valve nut.
6 Attach the foot filter to the
other end of the tubing
7 Attach the second piece
of the clear PVC flexible
8 The pump should be set
to the “T” (time). In this
using the same process tubing to the orange barb. mode 0 - 100% equals
and place vertically in the Place the other end of 0-60 seconds. In the “F”
stock solution. tubing into stock solution. position, the pump will
stroke 1 time per pulse
from the Water Meter.
Part C: Putting the pump in operation
1 To begin, set frequency
adjusting knob to 100%.
2 Unscrew the cover plate
that reads EXT signal.
3 Insert the contact plug
where it reads EXT signal
4 Unscrew the air bleed
valve nut, the solution
Then, plug the pump in. it will prime for 60 secs. will begin to go down
Remove plug. through the priming tube.
Once this has finished,
re-tighten the nut.
5 Attach the Water Meter
wires to the pre-wired
6 Wrap the wires with
electrical tape or wire
7 Insert the plug where it
reads EXT signal.
! CAUTION
plug, polarity does not nuts (not provided). See operating manual for
matter. complete instructions and
safety standards. When
connecting a metering pump
either to a public water supply
or to its own water source,
you must respect the
regulations in force concerning
protection of the source i.e.
backflow prevention, etc.
NOTE: Remove safety labels before installing and remember that pumps may hold water inside.
Water Meter Options
WM34-1PPG One pulse per gallon NEED HELP? Call 1-800-451-6628
WM34-10PPG One pulse per 10 gallons
PKX
Basic