CC2800-1 CC 2800-1 CC2800-1 106.

5t LOX Tank T622A


General 1 2 3
Load Case
Configuration SSL - 60tCB
Track Width 8.4 x 8.4 m Crane Parameters 13600
Boom System Radius m 16 14 14
Main Boom Length 72 m Slew Range ° 0 119 - 0 0
Counterweight Superstructure CW Radius m 6.18 6.18 6.18
Derrick Radius m 11.5 11.5 11.5
Superstructure CW 160 t
Ballast Radius m 11 11 11

R72000
Superstructure CW Radius 6.18 m

5000
Ballast Weight t 0 0 0

CC 28
Central CW 60 t
Active Ballast Weight t 0 0 0

0
Hook Block

0-1
Load Chart Capacity t 157 195 195

106.5t

3500
HB Weight 10.4 t Load Parameters

90° Load t 106.5 106.5 106.5


Tackle t 2.6 2.6 2.6 00-1
CC 28
Hook Block t 10.4 10.4 10.4
Total Load t 119.5 119.5 119.5
C A
Utilisation
Load Chart Utilisation % 76.1 61.3 61.3
180° 0°
Static Ground Bearing Pressure

00
40
R1
A: 5 m (Width) kN/m² 188 199 157
D B B: 5 m (Width) kN/m² 188 96 157

R16
C: 5 m (Width) kN/m² 0 0 0

00
0
36200 D: 5 m (Width) kN/m² 0 0 0

Ground preparations
106.5t
Area to be hardened & levelled by the client CC2800-1 LOX Tank T622A
Ground bearing pressure up to 200 kN/m²
Max. Wind Speed according to Load Chart 9.8 m/s
Level requirements : 0° ± 0.3 (±° 0.5 %)
Max. Wind Sail Area according to Load Chart 143 m²
SAFETY NOTE Wind Resistance Coefficient Cw 1.2
IF IN DOUBT: STOP WORK; Projected Surface of the Load 105 m²
C:\Users\ybelaiouer\Sarens\Yassine AMROUCHE - Projects\Arzew - Complexe de Liquéfaction\Renaissance\S-20-14299\Engineering\valid\S-20-14299_DR004_A.dwg, 09/02/2021 15:36:33

EXECUTE 'STOP and Actual Surface of the Load 126 m²


CONSULT' PROCEDURE!
Actual Surface of the Load < Max Sail Area Tackle Arrangement
Max. Wind Speed for Lifting 9.8 m/s Description Capacity Length Weight/pce Weight
Item Quantity
WLL
N° t mm kg kg
1 2 - Wire Sling 85 16000 100 200
2 4 - Wire Sling 50 6000 75 300
600t 600t

3 2 - Synthetic Slings 100 20000 110 220


4 4 - Shackles 125 - 120 480
5 4 - Shackles 85 - 70 280
6 1 - Spreader Bar (S406) 279 10000 1800 1800
1
R30

Reference Drawings
000

Notes
0
1600

4 Overall Plot Plan Including Existing Storage 1 Position of COG to be confirmed by client
1 Plot Plan Arzew Algeria
Document Number : DOC0000949682, Rev 3 2 Position and details of lifting points to be confirmed by client
3 Final weights to be confirmed by client
Cryogenic Liquid Tank
6 2 Item drawing 4 Soil stability is client responsability
Document Number : CFW-250/0.4, Rev 15
30100

A 09-02-2021 Lifting Tackles Updated Y.B. Y.A. Y.A.


20m length - 19-01-2021 First Issue Y.B. Y.A. Y.A.
10000
2
synthetic sling rev. date description designed verified approved
client:

3
Copyright Sarens group. All rights reserved. This document is the sole property of Sarens.
No license under any patent, or copyright, nor any other intellectual property, proprietary or
other right shall be granted to other parties, except for Sarens.

106.5t 6210 7480 equipment:


106.5t CC2800-1 Configuration SSL 72m Main Boom
description:
1200 2500 Installation of LOX Tank T622A (106.5t)

site: proj.:
3000

Haoud Berkaoui - Air Separation Unit


owner: drawing type: size:
SAR Lifting Drawing A3
appr. state: project: scale:
For Execution S-20-14299 1/333
14000 doc No.: sheet:
S-20-14299_DR004 1-1