D1SA Series
Model D1SA-RN D1SA-GN Positive logic (PNP) Negative logic (NPN) • Based on the reversed order of pin, 4-digit, connection of rear part of the product,
Display method 7-segment LED (red) 7-segment LED (green) 5V
use Zero Blanking.
100 kΩ
INSTRUCTION MANUAL
Power supply 12 - 24 VDCᜡ INPUT IC ■ Parallel input
20 kΩ
Allowable voltage range 90 to 110 % of power supply
• Static Parallel
Current consumption ≤ 35 mA 20 kΩ 100 kΩ
IC DP DP DP DP
Size W 11 × H 22 mm INPUT D3 D3 D3 D3
Data
Decimal number: 0 to 9, decimal point D2 D2 D2 D2 input
DRW201174AB Display character D1 D1 D1 D1
Hexadecimal number: 0 to 9, A to F, decimal point
D0 D0 D0 D0
Thank you for choosing our Autonics product. • Blank: Though entering the data, it will not display. D2 D2 D2 D2
Input resistance 20 kΩ
D3 D3 D3 D3 Next digit
BI BI BI BI
BO
Read and understand the instruction manual and manual thoroughly before Input level High: 4.5 - 24 VDCᜡ, Low: 0 - 1.2 VDCᜡ 7-seg Display Negative logic (NPN) input Positive logic (PNP) input
BO
LE
BO
LE
BO
LE
BO
LE
LATCH
using the product.
DP DP DP DP
Hex. Dec. D3 D2 D1 D0 D3 D2 D1 D0
GND GND GND GND
Max. Cock 02) ≤ 3 kHz GND
For your safety, read and follow the below safety considerations before using. 1 10 10 1 1010
Output Data output (serial input), Zero Blanking output H H H H L L L L CN1 CN1
For your safety, read and follow the considerations written in the instruction
0 0
100 101 102 103
Input logic Positive logic (PNP), negative logic (NPN) selectable (function set switches) H H H L L L L H
manual, other manuals and Autonics website.
1 1
Between power terminals or input terminals H H L H L L H L • Dynamic Parallel
Keep this instruction manual in a place where you can find easily. Noise immunity
2 2
: ± 300 V the square wave noise (pulse width: 1 μs) by the noise simulator H H L L L L H H LATCH 0
The specifications, dimensions, etc. are subject to change without notice for product
3 3
Ambient temperature 0 to 60 ℃, storage: -10 to 85 ℃ (no freezing or condensation) H L H H L H L L
LATCH 1
Safety Considerations
7 7 D2 D2 D2 D1
D2
Weight (packaged) 03)
≈ 16 g (≈ 131 g) 8 8 L H H H H L L L
D3
BI
D3
BI
D3
BI
D3
BI
D2
D3
BO
BO BO BO BO
01) When applying the serial 4-bit input. L H H L H L L H LE LE LE LE Next digit
• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
9 9 DP DP DP DP
02) Max. Clock is for 1:1 of duty ratio (ON, OFF ratio). DP
Blank L H L H H L H L
GND GND GND GND
GND
• symbol indicates caution due to special circumstances in which hazards may occur. 03) The package weight is based on four.
A
1 1010 1 1010 1 1010 1 1010
B Blank L H L L H L H H CN1 CN1 CN1 CN1
Warning
100 101 102 103
Failure to follow instructions may result in serious injury or death. Blank L L H H H H L L
Sold Separately ■ Serial input
C
D Blank L L H L H H L H
01. Fail-safe device must be installed when using the unit with machinery that Blank L L L H H H H L
• Caps: DAR (L)-R (1 set - left and right, D1SA-RN dedicated)
E DI
Data input
may cause serious injury or substantial economic loss.(e.g. nuclear power Blank L L L L H H H H
• Caps: DAR (L)-BL (1 set - left and right, D1SA-GN dedicated) CN2 CN2 CN2 1 CN2 1
F
1 1
control, medical equipment, ships, vehicles, railways, aircraft, combustion VCC VCC VCC VCC
VCC
Unit Descriptions
DI
Dimensions
DO DO DO DO
Failure to follow this instruction may result in personal injury, economic loss or fire.
Next digit
BI BI BI BI
BO BO BO BO BO
02. Do not use the unit in the place where flammable/explosive/corrosive gas, LE
DP
LE
DP
LE
DP
LE
DP
LATCH
high humidity, direct sunlight, radiant heat, vibration, impact or salinity • Unit: mm, For the detailed drawings, follow the Autonics website. GND GND GND GND
GND
②
1 10 10 1 10 10 1 10 10 1 10 10
may be present. 3.5 54 CN1 CN1 CN1 CN1
①
Failure to follow this instruction may result in fire.
Zero Blanking
7
6
04. Do not connect, repair, or inspect the unit while connected to a power S4 J2 J1 S3 S2 S1
5
33
22
4
source. 3 • This function removes '0' that is no meaning when displaying the data in the multi-
Failure to follow this instruction may result in fire. stage connection.
2
②
A 1
05. Check 'Unit description and function setting' before wiring. • Set J2 (Zero Blanking) as ON.
Failure to follow this instruction may result in fire. ■ Panel cut-out • Set 100 as OFF to display '0'. Connect BI terminal to GND for deactivating Zero Blanking.
06. Do not disassemble or modify the unit. ① Function set switches
Digit Size A Size B ■ Using Zero Blanking
Failure to follow this instruction may result in fire. (N) (20×N+12) (20×N+10) • Open : OFF / Short : ON
V+ • Display e.g.: 10
1 32 30 ± 0.1
Caution
31
Failure to follow instructions may result in injury or product damage. No. ON OFF Function Default BI BO BI BO BI BO BI BO 103 102 101 100
2 52 50 ± 0.1
S1 Decimal number Hexadecimal number Display characters ON GND
B 3 72 70 ± 0.1
1 0
103 102 101 100
01. Use the unit within the rated specifications. S2 Parallel Serial Input ON
Failure to follow this instruction may result in fire or product damage. 4 92 90 ± 0.1
S3 5 bits 4 bits Select serial input OFF ■ Not using Zero Blanking
02. Use a dry cloth to clean the unit, and do not use water or organic solvent. 5 112 110 ± 0.1
J1 Use Not used Serial data output 01) OFF • Display e.g.: 10
Failure to follow this instruction may result in fire. 6 132 130 ± 0.1
J2 Use Not used Zero Blanking OFF BI BO BI BO BI BO BI BO 103 102 101 100
03. Keep the product away from metal chip, dust, and wire residue which flow 7 152 150 ± 0.1
S4 Negative logic (NPN) Positive logic (PNP) Input logic ON
GND
into the unit. 8 172 170 ± 0.1
0 0 1 0
103 102 101 100
01) S
et as ON in serial input, as OFF in parallel input.
Failure to follow this instruction may result in fire or product damage.
■ Connector (CT-10S) ② I/O terminal
19 Input Parallel input Serial input
Cautions during Use 13.5 Terminal Code Function Code Function
7.5 2-Ø 3.4 7.5
7.5 1 V+ 12 - 24 VDCᜡ VCC 12 - 24 VDCᜡ
• Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected
accidents. 2 D0 N·C -
• 12 - 24 VDCᜡ model power supply should be insulated and limited voltage/current or 3 D1 CK Clock input
Data input
Class 2, SELV power supply device. 4 D2 DI Data input
• Install a power switch or circuit breaker in the easily accessible place for supplying or 5 D3 DO Data output
disconnecting the power. 6 BI Zero Blanking input BI Zero Blanking input
42
37
23
32
• Keep away from high voltage lines or power lines to prevent inductive noise. In case 7 BO Zero Blanking output BO Zero Blanking output
installing power line and input signal line closely, use line filter or varistor at power line 8 LE LATCH input LE LATCH input
and shielded wire at input signal line. 9 DP Decimal point input DP Decimal point input
Do not use near the equipment which generates strong magnetic force or high 10 GND 0V GND 0V
frequency noise.
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000 m
- Pollution degree 2
- Installation category I