LED Flood Light
400W
  300
  -
Advantages      IP66
 Patent private mould, integrated die-casting
 AL. Modular combination available.
 High efficiency, 130lm/W available.
 Glare free lens: 30°/60°/90°/80*140°/80*150°.
 IP66.
Dimension
             387
       590
                   63
                        Application
                        Billboard
                        Road
                        Tunnel
                        Bridge and
                        culvert Square
                        Building
Technical
Specification
A: Technical Parameter                                          B: Mechanical Specifications
                                                                LED Driver                   MEANWELL (HLG-320-48A/36A)*1
 Item No.                        FDL-S1-400W    300w
                                                                                             Philips (PLG-150-48A/36A)*2
 LampSize                        590*387*63mm
                                                                  Housing Processing         Die-Casting
 Voltage                         AC 240V 50/60HZ
                                           300-400W               Material                   ADC12
 Power                           400W
 LED Type                        5050
 LED Quantity                    288pcs
                                                                C: Environmental
 LED Luminous Efficiency         130lm/W
                                                                  Temperature Range                  -40℃ ~ 50℃
 Luminous Flux                   52000lm                          Operating
                                  110000hours                     Humidity Range Operating           10% ~ 90%
Lifetime Usage
                                                                  Temperature Range                  -40℃ ~ 70℃
Color                            6000K
                    Cool white                                    Storage
Temperature                                                       Humidity Range Storage             10%~ 90%
Beam Angle                       30°/60°/90°/ 80*140°/80*150°     Material                      UV Resistant finish
Color Rendering I ndex (CRI)     Ra>80                            Dust                       Dust proof and waterproof
Power Supply Efficiency          >90%
Power Factor (PF)                >0.9
Surge Protection                 Upto 10KV or 20KA
IP Rank                          IP 66
Impact Protection                IK08
Certificate                      CE, CB, SAA
Warranty                         1 Year
                                 Luminous Intensity Distribut
                                            Illumination        Cone
CurveDistribution     Curve of                      Conical Intensity Distribution
                                                             Curve of Max Intensity
                Meridian
                                                                  c180
                  -/+180                               c210                  c150
    -                             12
                                                c24                                 c12
-                                      9
                  6340                        c27                                        c9
                                                                  6340
                  1268
                    0                                             12680
        -                         6
                  1902                          c30               19020             c6
            -       0       3    Unit: cd                         25360
                  2536            — c0                   c330               c30
                                  /180                        31700           Street
                                    —         House Side
                                 c30/210            Locatio o Peak: γ =
Luminous Intensity Distribution
                        H[m]      Diameter[m]   Illuminance[lx]
Luminous Intensity Distribution
                        1.0                  31689.88
                                             31293.45
                        2.0                  7922.47
                                             7823.36
                        3.0                  3521.10
                                             3477.05
                        4.0                  1980.62
                                             1955.84
                        5.0                  1267.60
                                             1251.74
                                  C0-C180
                                  C90-C270
                                Luminous Intensity Distribut
                                        Illumination Cone Curve
      Distribution Curve of Meridian          Conical Intensity Distribution Curve
                                                       of Max Intensity
                 -/+180                                       c180
         -150              150                        c210             c1503189.50
 -120                             120                                                  C0-C180 C90-C
                                              c240                            c120
-90                                    90
                  16500                     c270                                 c90
                                                             16500
                  33000
                                                             33000
  -60             49500           60
                                              c300           49500            c60
                  66000
          -30              30                                66000
                  82500          Unit: cd
                   0            — c0 /180            c330    82500      c30
                                — c30/210                     c0
                                — c60/240   House Side                  Street Side
                                — c90/270        Location of Peak:γ = 4.5°
Installation
               With support frame
               Fix the bracket on the wall by screws and then
               adjust the lamp body to proper orientation .
Installation
                                        387
                      590
 Check if the input voltage of the lamp is compatible with local mains supply. Connect the input
 power cables with the mains supply.
 The blue cable is neutral line, the brown one is live line, and the green one
 is earth wire. (See picture 1)
Packing
EPE
      Bo
      x
                         Type    Carton Size    Quantity    G.W.
           Flood Light
                         Box    645*405*115mm     1pcs     9.2Kgs
Attention
    1.    Please read the manual carefully before installation.
    2.  Please check everything carefully before use.If any
      abnormal ities occurred during use, please contact us i mmedi ately.
    3.    It is a normal phenom enon that the surface temperature     of the lamp
         get higher during use.
    4. Please do   not disassemble the lamp without permission, or it will be deemed to have
         waived the warranty service.
    5.  For products with special function, the corresponding sections in this
      manual is for reference only.
Warranty
  5-year warranty since the date of purchase is offered for all Flood Light.
         Warranty terms
  1.
        Under the warranty terms, if the products break down under normal usage within warranty period, We will
        provide free maintenance service based on the proof-documents and invoice (copy) of failure product.
  2.
        We will not provide paid maintenance service under following conditions even within warranty.
        a. Failure or damage due to force majeure.
        b. Failure or damage due to transport or unloading.
        c. Failure or damage due to incorrectly usage or fail to comply with the User's Guide and Caution.
        d. Failure or damage due to demolition, repair alteration without Manufacturer’s authorization.
   3.
        Please deliver the failure product by original packing for maintenance service, We will not be responsible for
        any failure or damage by transportation if customer use non-original packing or improper packing.
  4.
        We reserves the right for final explanation of aforesaid terms.
  Cautions: We will not be responsible for any other failure or damage by incorrectly usage.