365 B-7-1-2 Fire hydrant system -

Fire hydrant steel pipe-mmened hot-dip galvanized steel pipe


1. Installation location: indoors
366 2. Material and specification: mmened hot-dip galvanized steel pipe DN65 m 1,530.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing
Fire hydrant steel pipe-mmened hot-dip galvanized steel pipe
1. Installation location: indoors
367 2. Material and specification: mmened hot-dip galvanized steel pipe DN100 m 455.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing
Fire hydrant steel pipe-mmened hot-dip galvanized steel pipe
1. Installation location: indoors
368 2. Material and specification: mmened hot-dip galvanized steel pipe DN150 m 2,873.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing
Fire hydrant steel pipe-mmened hot-dip galvanized steel pipe
1. Installation location: indoors
369 2. Material and specification: mmened hot-dip galvanized steel pipe DN200 m 195.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing
Indoor fire hydrant
1. Installation method: concealed installation
2. Model and specifications: One single-outlet fire hydrant DN65mm fire hydrant, water gun
nozzle diameter 19mm; one linen-lined glue tape, 25m long; one set of fire hose reel, fire hose
370 set 300.00
inner diameter 25mm, long 30m, nozzle diameter 6mm, model MF/ABC5 2 portable ammonium
phosphate dry powder fire extinguishers
3. Accessory materials and specifications: the fire hydrant box is a combined fire cabinet with a
fire extinguisher box
Fire extinguisher
1. Form: Portable
371 pcs 500.00
2. Specifications and models: Ammonium phosphate dry powder fire extinguisher, model
MF/ABC5, fire extinguishing agent filling capacity is 5Kg/piece
372 B-7-1-3 Fire sprinkler system -

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
373 2. Materials and specifications: hot-dip galvanized steel pipe DN25 for inner and outer walls m 3,600.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
374 2. Materials and specifications: hot-dip galvanized steel pipe DN32 for inner and outer walls m 3,750.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
375 2. Materials and specifications: hot-dip galvanized steel pipe DN40 for inner and outer walls m 5,520.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
376 2. Materials and specifications: hot-dip galvanized steel pipe DN50 for inner and outer walls m 1,600.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing
Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
377 2. Materials and specifications: hot-dip galvanized steel pipe DN65 for inner and outer walls m 800.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
378 2. Materials and specifications: hot-dip galvanized steel pipe DN80 for inner and outer walls m 400.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
379 2. Materials and specifications: hot-dip galvanized steel pipe DN100 for inner and outer walls m 1,570.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Water spray steel pipe - hot-dip galvanized steel pipe for inner and outer walls
1. Installation location: indoors
380 2. Materials and specifications: hot-dip galvanized steel pipe DN150 for inner and outer walls m 2,280.00
3. Connection form: threaded connection
4. Test: pressure test, water flushing

Pendant nozzle
1. Installation location: Place with suspended ceiling
381 pcs 1,650.00
2. Material, model, specification: pendant nozzle, 68℃ 3. Decorative plate design requirements:
with decorative plate
Upright nozzle
1. Installation location: no ceiling area
382 pcs 1,350.00
2. Material, model, specification: vertical nozzle, 68℃
3. Decorative plate design requirements: no decorative plate
Flow indicator
383 1. Specification and model: DN100 pcs 4.00
2. Connection form: flange connection
Flow indicator
384 1. Specification and model: DN150 pcs 9.00
2. Connection form: flange connection
Pressure reducing orifice plate
385 1. Specification and model: DN100 pcs 4.00
2. Connection form: flange connection
Pressure reducing orifice plate
386 1. Specification and model: DN150 pcs 9.00
2. Connection form: flange connection
Terminal water testing device.
387 1. Specification: DN25 set 5.00
2. Assembly form: Internal thread
Water test valve
388 1. Specification: DN25 pcs 3.00
2. Assembly form: Internal thread
389 B-7-1-4 Bracket supports and relevant fittings -
Pipe support
390 1. Material: Section steel kg 10,244.00
2. Name: Pipe bracket
Metal structure brushing oil
1. Position: Pipe supports and hangers are brushed with oil.
391 kg 10,244.00
2. Design requirements for rust removal and oil brushing: two coats of camphor anti-rust paint
and two coats of white alkyd enamel paint.
Wall bushing
392 1. Specification: DN150 pcs 6.00
2. Material: cast steel
Wall bushing
393 1. Specification: DN200 pcs 8.00
2. Material: cast steel
Fireproof hole blocking
394 item 19.00
1. Installation parts: fire hydrants and sprinkler risers
395 B-7-1-5 Pipes and accessories -
Butterfly valve DN65
1. Type: butterfly valve with opening and closing mark
396 2. Material: ductile cast iron pcs 300.00
3. Specification, pressure level: DN65
4. Connection form: flange connection
Butterfly valve DN100
1. Type: butterfly valve with opening and closing mark
397 2. Material: ductile cast iron pcs 20.00
3. Specification, pressure level: DN100
4. Connection form: flange connection
Butterfly valve DN1150
1. Type: butterfly valve with opening and closing mark
398 2. Material: ductile cast iron pcs 50.00
3. Specification, pressure level: DN150
4. Connection form: flange connection
Signal valve DN100
1. Type: signal valve
399 2. Material: ductile cast iron pcs 4.00
3. Specification, pressure level: DN100
4. Connection form: flange connection
Signal valve DN150
1. Type: signal valve
400 2. Material: ductile cast iron pcs 14.00
3. Specification, pressure level: DN150
4. Connection form: flange connection
Gate valve DN100
1. Type: gate valve
401 2. Material: ductile cast iron pcs 10.00
3. Specification, pressure level: DN100
4. Connection form: flange connection
Gate valve DN200
1. Type: gate valve
402 2. Material: ductile cast iron pcs 14.00
3. Specification, pressure level: DN100
4. Connection form: flange connection
Safety valve DN65
1. Type: safety valve
403 2. Material: cast steel pcs 4.00
3. Specification, pressure level: DN65
4. Connection form: flange connection
Overpressure relief valve DN65
1. Type: overpressure relief valve
404 2. Material: cast steel pcs 6.00
3. Specifications, pressure level: DN65
4. Connection form: flange connection
water meter
1. Installation location : indoors
405 2. Model and specification: DN65 set 6.00
3. Connection form: flange connection
4. Accessory configuration: water meter accessories
Check valve DN100
1. Type: check valve
406 2. Material: cast steel pcs 2.00
3. Specifications, pressure level: DN100
4. Connection form: flange connection
Check valve DN150
1. Type: check valve
407 2. Material: cast steel pcs 4.00
3. Specifications, pressure level: DN150
4. Connection form: flange connection
Check valve DN200
1. Type: check valve
408 2. Material: cast steel pcs 2.00
3. Specifications, pressure level: DN200
4. Connection form: flange connection
Pressure Switch
409 1. Name: Pressure switch pcs 8.00
2. Specification: DN150
1. Name: Flow switch
410 pcs 3.00
2. Specification: DN150
1. Type: automatic exhaust valve
2. Material: bronze
411 pcs 20.00
3. Specification, pressure level: DN25
4. Connection form: internal thread
1. Type: rubber soft joint
2. Material: rubber
412 pcs 4.00
3. Specification, pressure level: DN50
4. Connection form: flange connection
1. Type: rubber soft joint
2. Material: rubber
413 pcs 8.00
3. Specification, pressure level: DN100
4. Connection form: flange connection
1. Type: rubber soft joint
2. Material: rubber
414 pcs 16.00
3. Specification, pressure level: DN150
4. Connection form: flange connection
1. Type: rubber soft joint
2. Material: rubber
415 pcs 4.00
3. Specification, pressure level: DN150
4. Connection form: flange connection
Y type filter DN100
1. Type: Y-type filter
416 2. Material: cast steel pcs 2.00
3. Specifications, pressure level: DN50
4. Connection form: flange connection
Y type filter DN100
1. Type: Y-type filter
417 2. Material: cast steel pcs 4.00
3. Specifications, pressure level: DN150
4. Connection form: flange connection
Y type filter DN100
1. Type: Y-type filter
418 2. Material: cast steel pcs 2.00
3. Specifications, pressure level: DN200
4. Connection form: flange connection
419 B-7-2 Gas fire extinguishing system -
Gas fire extinguishing device
420 m3 10,000.00
1. Gas fire extinguishing with pipe network
Super dry powder ball
421 set 250.00
1. Super dry powder balls
422 B-7-3 Othe fittings -
425 Debugging of sprinkler system fire hydrant system item 1.00
426 Gas fire extinguishing system debugging part 4.00
1954 Fire Engineering m2 2,109.00
1805 C-3-5 Fire hydrant in the stadium -
1. Name: Fire hydrant chamber
1806 set 4.00
2. Material and model: φ600 concrete well
1. Installation method: outdoor underground type
1807 set 4.00
2. Model and specifications: DN150

1. Installation location: outdoor


2. Material and specifications: seamless steel pipe DN200
1808 3. Connection form: grooved connection, including pipe fitting installation, not listed separately. m 600.00
4. Others: See and meet the design drawings and relevant specification requirements for details
5. Pipeline anti-corrosion epoxy coal pitch glass cloth three oils

1762 C-3-2 Outdoor fire protection -

1. Installation location: outdoor


2. Material and specifications: seamless steel pipe DN200
1763 3. Connection form: grooved connection, including pipe fitting installation, not listed separately. m 2,000.00
4. Others: See and meet the design drawings and relevant specification requirements for details
5. Pipeline anti-corrosion epoxy coal pitch glass cloth three oils

1. Installation location: outdoor


2. Material and specifications: seamless steel pipe DN100
1764 3. Connection form: grooved connection, including pipe fitting installation, not listed separately. m 600.00
4. Others: See and meet the design drawings and relevant specification requirements for details
5. Pipeline anti-corrosion epoxy coal pitch glass cloth three oils

1. Type: gate valve


2. Material: ductile cast iron
1765 pcs 15.00
3. Specification: DN200
4. Connection form: flange
1. Type: gate valve
2. Material: ductile cast iron
1766 pcs 6.00
3. Specification: DN100
4. Connection form: flange

1. Installation method: above-ground fire hydrant


2. Model and specifications: DN100
1767 set 20.00
3. Accessory materials and specifications: Please refer to the design drawings for details
4. The fire hydrant interface must be French standard

1. Installation location (indoor and outdoor): outdoor water meter well (L) 2000 x (B)1300
x(H)1500 mm
1768 set 41.00
2. Model and specification: DN200
3. Connection form: flange connection(including gate valves and flexible joints)
1. Installation location: Outdoor
1769 2. Model and specification: Fire water intake set 2.00
3. Accessories include gate valve and check valve, specification: DN100
1. Installation location: outdoor
1770 2. Model and specification: above-ground fire water pump adapter set 4.00
3. Accessories include gate valve and check valve, specification: DN150