SHACKLES

G-210 / S-210


Forged, Quenched & Tempered, with alloy pins.
Working Load Limit and Grade 6 permanently shown on every shackle.
1
• Hot-dip galvanized (G) or self colored (S).


Sizes 3/8 inch and below are mechanically galvanized.
Fatigue rated at 1-1/2 times the Working Load Limit at 20,000 cycles.
2
• Shackles can be furnished proof tested with certificates to designated
standards, such as ABS, DNV, Lloyds, or other certifications. Proof testing and
certification available when requested at the time of order, charges will apply.
3
• Approved for use at -40° C (-40° F) to 204° C (400° F).
• All 209 and 210 shackles can meet charpy requirements of 42 Joules (31 ft-lb)
avg. at -20° C (-4° F) upon special request.
4
• Meets or exceeds all requirements of ASME B30.26.
• Type Approval certification in accordance with ABS 2016 Steel Vessel Rules and
ABS Guide for Certification of Lifting Appliances available. Certificates available
5
when requested at time of order and may include additional charges.
• G-210 Screw pin anchor shackles meet the performance requirements of Federal Specification RR-C-271H,
Type IVB, Grade A, Class 2, except for those provisions required of the contractor.
6
• Look for the Red Pin®... the mark of genuine Crosby quality.
7
G-210 / S-210 Screw Pin Chain Shackles
Stock Dimensions Tolerance
8
Nominal Working No. Weight (mm) (+ / - mm)
Size Load Limit Each
(in)
1/4
5/16
(t)
0.5
0.75
G-210
1019150
1019178
S-210
1019169
1019187
(kg)
.05
.08
A
11.9
13.5
B
7.85
9.65
C
6.35
7.85
D
6.35
7.85
E
24.6
29.5
F
15.5
19.1
G
22.4
26.2
K
40.4
48.5
L
4.85
5.60
M
35.1
42.2
G
1.50
1.50
A
1.50
1.50
9
3/8 1 1019196 1019203 .13 16.8 11.2 9.65 9.65 35.8 23.1 31.8 58.5 6.35 51.5 3.30 1.50
7/16
1/2
5/8
1.5
2
3.25
1019212
1019230
1019258
1019221
1019249
1019267
.20
.27
.57
19.1
20.6
26.9
12.7
16.0
19.1
11.2
12.7
15.7
11.2
12.7
16.0
41.4
46.0
58.5
26.9
30.2
38.1
36.6
41.4
51.0
67.5
77.0
95.5
7.85
9.65
11.2
60.5
68.5
85.0
3.30
3.30
3.30
1.50
1.50
1.50
10
3/4 4.75 1019276 1019285 1.20 31.8 22.4 20.6 19.1 70.0 46.0 60.5 115 12.7 101 6.35 1.50
7/8
1
1-1/8
6.5
8.5
9.5
1019294
1019310
1019338
1019301
1019329
1019347
1.43
2.15
3.06
36.6
42.9
46.0
25.4
28.7
31.8
24.6
25.4
31.8
22.4
25.4
28.7
81.0
93.5
103
53.0
60.5
68.5
71.5
81.0
91.0
135
151
172
12.7
14.2
16.0
114
129
142
6.35
6.35
6.35
1.50
1.50
1.50
11
1-1/4 12 1019356 1019365 4.11 51.5 35.1 35.1 31.8 115 76.0 100 191 17.5 156 6.35 3.30

12
1-3/8 13.5 1019374 1019383 5.28 57.0 38.1 38.1 35.1 127 84.0 111 210 19.1 174 6.35 3.30
1-1/2 17 1019392 1019409 7.23 60.5 41.4 41.1 38.1 137 92.0 122 230 20.6 187 6.35 3.30
1-3/4 25 1019418 1019427 12.1 73.0 51.0 54.0 44.5 162 106 146 279 25.4 231 6.35 3.30
2 35 1019436 1019445 19.2 82.5 57.0 60.0 51.0 184 122 172 312 31.0 263 6.35 3.30

13
2-1/2 55 1019454 1019463 32.5 105 70.0 66.5 66.5 238 145 203 377 35.1 330 6.35 6.35

6:1 Design Factor. Maximum Proof Load is 2 times the Working Load Limit. For Working Load Limit reduction due to side loading applications, see Warnings & Applications.