AREA STATEMENT:

PLOT AREA 600 . 00 SQ.M

PERMISSIBLE AREA -- . -- SQ.M

BUILD UP AREA:
PRO - G . FLOOR AREA 208 . 25 SQ.M

PRO - F . FLOOR AREA 187 . 88 SQ.M


N
TOTAL AREA 396.13 SQ.M

NOTES : -
HT - HOLDING TANK - 3.00 X 2.00 X 2.50 M

ST - SEPTIC TANK - 3.00 X 2.00 X 2.50 M

PIT FOR ELECT. CONNECTION - 0.45 X 0.45 M

PIT FOR WATER CONNECTION - 0.45 X 0.45 M

PIT FOR TELE. CONNECTION - 0.45 X 0.45 M

PROP - BOUNDARY WALL - 0.45 X 0.45 M

G 1 - M.S GATE - 1.5 X 2.0 M


2
G 2 - M.S GATE - 3.0 X 2.0 M
30.01 M
NOTES:-

3.10 M
1. ALL THE BOUNDARY POINTS (ALAMA) GIVEN IN KROOKIE
7.60 M

3.10 M
3 SHALL BE ESTABLISHED AT SITE BY APPROVED AUTHORITY ,
BEFORE THE START OF EARTH WORK EXCAVATION.
2. THE SITE SHALL BE CLEANED PROPERLY REMOVING BUSHES ,
DEBRIS OR OLD DAMAGED BUILDING IF ANY.
9.30 M COMPOUND
WALL
20.00 M

GATE LIGHT

G2

.
M ONLY
14.40 M
14.90 M

20.00 M

BE FOR 5
C COPYRIGHT : -

EDGE
PROPOSED This drawing is protected by copyright. All rights are reserved.
0.50M

G . FLOOR No part of this drawing may in any form or by any means be reproduced,

E ROAD
SHOULD
OULD BE PHALT ROAD ,
ST published, broadcast or transmitted without the prior written permission
of the Muruj Engineering consultancy office.

UP TO TH
NO: DATE REVISION BY: APP:

WHEN TH K TILE PAVING


ERE IS AS
1.
HT50M
7.60 M S
V I CE
8.00 M SER

INTERLOC
2.00 M

&
NY
THAT SH

NG I NNN ER I NG CON S UL TA
1 MURUJ
1.50M

Engineering Consultancy & Services

UJ E
G1
2.00 M

MU R
Al Kamil
WhatsApp:- 90 90 45 60
30.00 M COMPOUND
WALL
GATE LIGHT
Email : - murujalkamil@gmail.com
CLIENT NAME :

4 Mr . TAAEER BADAR TAAEER AL RASBI


PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TITLE : -
SITE PLAN & KROOKIE
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 1 / 21
INTERNAL FINISHES
FINISHING CODES SCHEDULE OF DOOR'S
WALL FLOOR
SCHEDULE CEILING SKIRTING SOLID MIRANTI WOOD DECORATIVE
MD 150 X 250
TYPE DESCRIPTION
DOOR

TWO COATS OF APPROVED EMULSION PAINT


120 X 240 SOLID MIRANTI WOOD DECORATIVE
W-1 OVER ONE COAT OF PRIMER AND TWO COATS D 120 X 250 DOOR
OF PUTTY
A C E G H W-2 CERAMIC WALL TILE
SOLID MIRANTI WOOD DECORATIVE
D1 100 X 220 DOOR
F-1 CERAMIC / PORCELAIN FLOOR TILE
1490 F-2 NON SLIPPERY CERAMIC FLOOR TILE D2 80 X 220 SEMI - SOLID TEAK PLYWOOD DOOR
TWO COATS OF APPROVED MATT EMULSION
SCHEDULE OF WINDOW'S
10 300 440 540 190 10 C-1 OVER ONE COAT OF PRIMER AND TWO COATS
OF PUTTY
WHITE POWDER COATED ALUMINUM
M ±000 40
S CERAMIC SKIRTING W 100 X 200 WINDOW 9.2cm SECTION WITH 6 mm
40
40 REFLECTIVE GLASS.

10
M F.G.L.
10

10
M MARBLE ( TREAD,RISER,SKIRTING & LANDING)

10
30

30

30
M

10
W1 W1

40
40

M WHITE POWDER COATED ALUMINUM


1 1 GENERAL NOTES:-
W1 150 X 120 WINDOW 9.2cm SECTION WITH 6 mm
REFLECTIVE GLASS.
120 150 120 110
D1 185 150 185 W2 F2
C1
1. ALL THE DRAWINGS SHALL BE READ

10
10 WHITE POWDER COATED ALUMINUM
BATH CAREFULLY BEFORE THE COMMENCEMENT

250
W1 F1
C1 S
W2 100 X 200 WINDOW 9.2cm SECTION WITH 6 mm
170 X 220 OF WORK. REFLECTIVE GLASS.
W1 F1
STORE

340
W2 F2 C1 S +077
C1 2. ALL DIMENSIONS ARE IN CENTIMETERS, WHITE POWDER COATED ALUMINUM
200 X 310 F.F.L
V V 50 X 120 VENTILATOR HALF LOUVERED AND
BED ROOM
470

KITCHEN +080 D2 UNLESS OTHERWISE SPECIFIED. HALF FIXED TYPE


520 X 440

arch
500 X 440 F.F.L
+080
3. WRITTEN DIMENSIONS ARE TO BE
+080 FOLLOWED, NO DIMENSION SHALL BE
F.F.L

CUPBOARD
F.F.L
DRESS

220
SCALED FROM THE DRAWINGS.
190 X 150

arch
W1 F1 4. ALL DRAWINGS ARE INTER-RELATED AND

130
C1 S D1 W1 F1
20 C1 S SHALL BE READ IN CONJUNCTION WITH
D1
OTHER DRAWINGS.
2 arch 2
CUPBOARD

W2 F2
C1
19 20 21 22 23 24 5. ANY AMBIGUITIES / DISCREPANCIES FOUND
140

arch
WASH 18 M M M IN THE DRAWING SHALL BE BROUGHT TO

210
190 X 120
UP

210
THE NOTICE OF THE ENGINEER, BEFORE THE
17 M
D2
HALL M
COMMENCEMENT OF RELEVANT ITEM OF
W2 F2 16 1
V C1
15 M 500 X 310 M 2 WORK.
3
1440

1440
BATH
190

14 13 12 11 10 9 8 7 6 5 W1 F1 6. PLINTH LEVELS SHALL BE ESTABLISHED AT


M C1 S
160 X 170 M M M M M
3
SITE IN CONSULTATION WITH ENGINEER.
+077 4
2.00 M WIDE
F.F.L 7. ANY DISCREPANCY OR ERRORS MUST BE
X X
PASSAGE
4 D1 W1 F1
C1 S BROUGHT TO THE KNOWLEDGE OF THE

FAMILY HALL CONSULTANCY BEFORE THE


arch
W2 F2

380
C1
10
500 X 800 CONSTRUCTION.
BATH
270

+080 8. METAL MET SHALL BE FIXED BEFORE


30 160 X 250
+080
340

F.F.L

610
+077 PLASTERING AT CONCRETE BLOCK WORK
F.F.L F.F.L
V JOINTS IN SUPER STRUCTURE.
W1 F1
D2 9. ALL EXPOSED CORNERS SHALL BE PROVIDED
C1 S

W2 F2 MAJLIS WITH GI CORNER BEADING FINISHING.


C1
CUPBOARD

500 X 600 MD
10. ELECTRICAL , WATER AND OTHER SERVICE
WASH
+080
210

210

170 X 190 CONDUIT , CHASING / CUTOUTS SHALL BE


F.F.L
W1 F1 PROPERLY PACKED WITHOUT CAVITY AND
150

C1 S 120 100 80 100 120


METAL NET TO BE FIXED BEFORE C COPYRIGHT : -
ENTRANCE
280

arch
W1 F1
ENTRANCE 200 X 260
W W
5 PLASTERING. This drawing is protected by copyright. All rights are reserved.
No part of this drawing may in any form or by any means be reproduced,
190 X 120 +077 STANDARD NOTES:-
10
140

10 C1 S published, broadcast or transmitted without the prior written permission

130
Beam

+080
110 100 80 100 110 F.F.L of the Muruj Engineering consultancy office.
Beam
15

F.F.L
±000 45
1. ALL MATERIALS USED FOR CONSTRUCTION NO: DATE REVISION BY: APP:
6 M
D
W W
Beam
M
F.G.L.
6 SHALL COMPLY WITH RELEVANT OMANI
10

45 M M STANDARDS.
10

10
±000
15
40

M M
20 35 2. ALL CONSTRUCTION MATERIALS SHALL BE S
M F.G.L. M V I CE
SER
TESTED AS PER SPECIFICATIONS AND

&
NY
NG I NNN ER I NG CON S UL TA
10 190 520 220 540 10 STANDARDS.
3. ALL CONCRETE STRUCTURAL MEMBERS

1490 SHALL BE CAST USING CONCRETE OF GRADE MURUJ


Engineering Consultancy & Services

UJ E
AS SPECIFIED BY THE ENGINEER.

MU R
Al Kamil
4. ALL BLOCKS FOR CONSTRUCTION SHALL BE WhatsApp:- 90 90 45 60
A B D F H OF GOOD QUALITY AND SUPPLIED BY Email : - murujalkamil@gmail.com
APPROVED MANUFACTURER. CLIENT NAME :
5. ORDINARY PORTLAND CEMENT TO BE USED
Mr . TAAEER BADAR TAAEER AL RASBI
GROUND FLOOR PLAN FOR ALL THE CONCRETE, BLOCK
PLASTERING, AND TILE WORKS. UNLESS
PLOT NO : - LOCATION : - J . B .BUALI,
SCALE 1:100 ( ALL DIM ARE IN CM'S) 6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
OTHERWISE SPECIFIED.
TITLE : -
6. SULPHATE RESISTANT CEMENT HAS TO BE G.F FLOOR PLAN
USED FOR ALL WORKS UNDER GROUND
DESIGNED : - JOB NO : -
LEVEL, UNLESS OTHERWISE SPECIFIED. Hari 0083 / MECS
CHECKED : - SCALE : -
NOTES:- Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
· USE NON SLIPPERY GROOVED STEP TILES CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023
OR MARBLES FOR ENTRANCE STEPS AND
USE & NO OF FLOORS : - NO OF SHEET : -
STAIRCASE Residential & G +1 2 / 21
INTERNAL FINISHES
FINISHING CODES SCHEDULE OF DOOR'S
WALL FLOOR
SCHEDULE CEILING SKIRTING SOLID MIRANTI WOOD DECORATIVE
MD 150 X 250
TYPE DESCRIPTION
DOOR

TWO COATS OF APPROVED EMULSION PAINT


120 X 240 SOLID MIRANTI WOOD DECORATIVE
W-1 OVER ONE COAT OF PRIMER AND TWO COATS D 120 X 250 DOOR
OF PUTTY
SOLID MIRANTI WOOD DECORATIVE
W-2 CERAMIC WALL TILE D1 100 X 220 DOOR
F-1 CERAMIC / PORCELAIN FLOOR TILE
A C E G H F-2 NON SLIPPERY CERAMIC FLOOR TILE D2 80 X 220 SEMI - SOLID TEAK PLYWOOD DOOR
TWO COATS OF APPROVED MATT EMULSION
OVER ONE COAT OF PRIMER AND TWO COATS SCHEDULE OF WINDOW'S
1490 C-1
OF PUTTY
WHITE POWDER COATED ALUMINUM
S CERAMIC SKIRTING W 100 X 200 WINDOW 9.2cm SECTION WITH 6 mm
10 300 220 220 540 190 10 REFLECTIVE GLASS.
M MARBLE ( TREAD,RISER,SKIRTING & LANDING)
WHITE POWDER COATED ALUMINUM
40 40 W1 150 X 150 WINDOW 9.2cm SECTION WITH 6 mm
40
GENERAL NOTES:-
10

10
REFLECTIVE GLASS.

10

30
10

10

40
40

V W1 1. ALL THE DRAWINGS SHALL BE READ


WHITE POWDER COATED ALUMINUM
1 1 CAREFULLY BEFORE THE COMMENCEMENT W2 100 X 200 WINDOW 9.2cm SECTION WITH 6 mm

10
W2 F2 185 150 185
W2 F2
C1 OF WORK. REFLECTIVE GLASS.
C1
W2 D2 BATH

100

10
W1 F1 10 2. ALL DIMENSIONS ARE IN CENTIMETERS, WHITE POWDER COATED ALUMINUM
250 X 120 BATH

250
C1 S
V 50 X 200 VENTILATOR HALF LOUVERED AND
170 X 220 UNLESS OTHERWISE SPECIFIED. HALF FIXED TYPE
330

H/M ROOM W1 F1 3. WRITTEN DIMENSIONS ARE TO BE


W2 F2
200 X 300 LANDRY C1 C1 S
V FOLLOWED, NO DIMENSION SHALL BE

190
250 X 170 BED ROOM D2
SCALED FROM THE DRAWINGS.
520 X 440
4. ALL DRAWINGS ARE INTER-RELATED AND
D1 D1

CUPBOARD
SHALL BE READ IN CONJUNCTION WITH

220
DRESS
OTHER DRAWINGS.

arch
170 X 150
140

DN D1 5. ANY AMBIGUITIES / DISCREPANCIES FOUND


D1 IN THE DRAWING SHALL BE BROUGHT TO
2 arch 2 THE NOTICE OF THE ENGINEER, BEFORE THE
UP 19 20 21 22 23 24 CUPBOARD W2 F2
C1 COMMENCEMENT OF RELEVANT ITEM OF
105

18 M M M
DN

CUPBOARD

210
W1 F1
W2 F2
C1 S BATH WORK.
17 M
C1 S DRESS 280 X 190 6. PLINTH LEVELS SHALL BE ESTABLISHED AT
330

W2 220 X 190 D2
100

OPEN 16 HALL V SITE IN CONSULTATION WITH ENGINEER.


15 M
TERRACE 360 X 310 arch 3 7. ANY DISCREPANCY OR ERRORS MUST BE
1440

1440
14 13 12 11 10 9 8 7 6
30 240 300 BROUGHT TO THE KNOWLEDGE OF THE
105

M M M M D1
CONSULTANCY BEFORE THE
40

4 X D1 X CONSTRUCTION.
8. METAL MET SHALL BE FIXED BEFORE
W2 F2
10 C1 PLASTERING AT CONCRETE BLOCK WORK
W1 F1
BATH JOINTS IN SUPER STRUCTURE.
270

C1 S
30 160 X 250 9. ALL EXPOSED CORNERS SHALL BE PROVIDED
BED ROOM

610
V
500 X 590 WITH GI CORNER BEADING FINISHING.
W1 F1 10. ELECTRICAL , WATER AND OTHER SERVICE
D2 C1 S
CONDUIT , CHASING / CUTOUTS SHALL BE
M. BED ROOM
PROPERLY PACKED WITHOUT CAVITY AND
720 X 600
W1 F1 METAL NET TO BE FIXED BEFORE C COPYRIGHT : -
CUPBOARD

C1 S
PLASTERING. This drawing is protected by copyright. All rights are reserved.
DRESS No part of this drawing may in any form or by any means be reproduced,
350

120 100 80 100 120 STANDARD NOTES:-


170 X 330 published, broadcast or transmitted without the prior written permission
arch

of the Muruj Engineering consultancy office.

W W
10
5 1. ALL MATERIALS USED FOR CONSTRUCTION NO: DATE REVISION BY: APP:
SHALL COMPLY WITH RELEVANT OMANI

130
110 100 80 100 180 100 50
15

CUPBOARD 45 STANDARDS.

6 W W
6 2. ALL CONSTRUCTION MATERIALS SHALL BE
TESTED AS PER SPECIFICATIONS AND
S
V I CE
SER

&
10

45

NY
10

10

NG I NNN ER I NG CON S UL TA
STANDARDS.
15
40

20 35
3. ALL CONCRETE STRUCTURAL MEMBERS
SHALL BE CAST USING CONCRETE OF GRADE MURUJ
10 190 520 220 540 10 Engineering Consultancy & Services

UJ E
AS SPECIFIED BY THE ENGINEER.

MU R
Al Kamil
4. ALL BLOCKS FOR CONSTRUCTION SHALL BE
1490 OF GOOD QUALITY AND SUPPLIED BY
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
APPROVED MANUFACTURER. CLIENT NAME :
5. ORDINARY PORTLAND CEMENT TO BE USED
A B D F H FOR ALL THE CONCRETE, BLOCK
Mr . TAAEER BADAR TAAEER AL RASBI
PLOT NO : - LOCATION : - J . B .BUALI,
PLASTERING, AND TILE WORKS. UNLESS
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
FIRST FLOOR PLAN 6.
OTHERWISE SPECIFIED.
SULPHATE RESISTANT CEMENT HAS TO BE
TITLE : -
G.F FLOOR PLAN
SCALE 1:100 ( ALL DIM ARE IN CM'S) USED FOR ALL WORKS UNDER GROUND
DESIGNED : - JOB NO : -
LEVEL, UNLESS OTHERWISE SPECIFIED. Hari 0083 / MECS
CHECKED : - SCALE : -
NOTES:- Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
· USE NON SLIPPERY GROOVED STEP TILES CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023
OR MARBLES FOR ENTRANCE STEPS AND
USE & NO OF FLOORS : - NO OF SHEET : -
STAIRCASE Residential & G +1 3 / 21
ELECTRICAL SYMBOLS
ELECTRICAL NOTES:-
E E

G
IN
CEILING FAN CALLING BELL 2.20M

IL
1. THIS ELECTRICAL PLAN SHALL BE READ

CE
TWO GANG
WITH ARCHITECTURAL DRAWINGS AND

G
20 mm PVC CONDUIT TO METER BOARD

INO -75 MM UPVC PIPE OR SLEAVE LAID


UNDER GROUND INO -4C X 35 SQ.MM
XLPE/SWA/PVC ARMORED CABLE

IN
CHANDELIER SWITCH TWO 2.20M

IL
CE
WAY
SPECIFICATIONS.

NG
FLUORESCENT BOX

I
MIRROR LIGHT 2.20M

IL
2. ALL ELECTRICAL WORKS SHALL BE CARRIED DOUBLE TUBE LIGHT

CE
G
OUT AS PER APPROVED DRAWING TO FLUORESCENT BOX

IN
FAN REGULATOR 1.50M

IL
DOUBLE TUBE LIGHT

CE
CONFORM WITH THE LATEST OMAN
FLUORESCENT BOX ONE GANG

G
1.50M

IN
ELECTRICAL STANDARDS AND SINGLE TUBE LIGHT

IL
SWITCH

CE
REGULATIONS. CEILING LIGHT TWO GANG
1.50M
SWITCH
3. SEPARATE D.B. SHALL BE USED FOR EACH
SPEAKER AC SOCKET & 1.50M
FLOOR AND ONE ADDITIONAL D.B FOR SWITCH
CAMERA 3.40M TV SOCKET & 1.50M
EXTERNAL WORKS SUCH AS SERVANT SWITCH
ROOM,PENT HOUSE, TERRACE FLOOR, WATER HEATER
WINDOW TYPE AC 2.20M SWITCH 1.50M
WATER PROOF & COMPOUND WALL LIGHTS AND PUMPS ETC.,
SPLIT UNIT AC 2.20M COOKER 0.80M
WEATHER PROOF 4. D.B'S SHALL BE INSTALLED IN COMMON
SOCKET (TYP) WALL LIGHT 2.20M T.V POSITION 0.50M
HALL.
EXHAUST FAN 2.20M TELE PHONE 0.50M
5. ALL WIRING SHALL BE WITH COLORS CODE
AND LABELED IN SERIAL NUMBER. WATER HEATER 2.20M INTERCOM 0.50M
6. ALL LOAD MUST BE BALANCED. 13 AMP SOCKET BELL PUSH Ext-
1.50M
TL
EL
7. EACH D.B SHALL BE EARTH IN SEPARATE AND SWITCH BUTTON Wall
MAIN DISTRIBUTION 2.20M
EARTH PIT. BOARD
1.50M SPOT LIGHT

8. ALL EARTH PITS SHALL BE PROVIDED WITH KEY HOLDER 2.20M SWITCH BOARD 2.20M

C.I COVER TO FACILITATE PERIODIC CEILING 6A SWITCH


2.20M SOCKET OUTLET 2.20M
PENDENT FOR CHIMNEY
INSPECTION.
FOOT LAMP AT 3PIN 166 SWITCH
9. METER BOARD SHALL BE INSTALLED 2.20M SOCKET OUTLET
9"LVL
TL AT 1800 mm
OUTSIDE OF THE HOUSE, PREFERABLY NEAR
EL EMERGENCY CEILING ROSE
EL
THE ENTRANCE GATE PROJECTING INSIDE LIGHT

THE COMPOUND WALL AS DETAILED IN THE WIFI - POINT


DRAWING WITH VIEWING GLASS OUT SIDE.

MDB
SPECIAL NOTES OF HIGH RISE BUILDINGS:

HDU
WATER PROOF & 10. HIGH RISE BUILDINGS SHALL BE PROVIDED
WEATHER PROOF
SOCKET (TYP) WITH LIGHTNING CONDUCTOR WITH
SEPARATE EARTH AS BRIEFED IN OES -4
(CLAUSE 8.19).
11. A SEPARATE ELECTRICAL ROOM SHALL BE
PROVIDED AND EQUIPPED WITH A/C UNIT,
WATER PROOF &
LAMP AND A RUBBER MAT IN FRONT OF THE
WEATHER PROOF
EL SOCKET (TYP) MAIN PANEL BOARD WITH SUFFICIENT
WORKING SPACE.
12. TWO SETS OF LINE DIAGRAM OF LOAD
EL DISTRIBUTION HAS TO BE SUBMITTED IN C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
ADVANCE FOR APPROVAL. No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
13. NEW APPROVED LINE DIAGRAM SHALL BE
of the Muruj Engineering consultancy office.
PRODUCED AT THE TIME OF INSPECTION. NO: DATE REVISION BY: APP:

S
V I CE
SER

&
NY
CABLE& CONDUIT FOR TELEPHONE TO OUT SIDE

NG I NNN ER I NG CON S UL TA
TO THE BOUNDARY WALL CABLE & CONDUIT

MURUJ
+1C X 15 SQ MM EARTH WIRE EXTENDED

Engineering Consultancy & Services

UJ E
MU R
Al Kamil
FOR GATE LIGHTS & BELL SWITCH

WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI


PLOT NO : - LOCATION : - J . B .BUALI,
BOUNDARY WALL

ELECTRICAL PLAN 6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH


TITLE : -
SCALE 1:100 ( ALL DIM ARE IN CM'S) G.F ELECTRICAL PLAN
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023 E T DATE : -
CAD DESIGNER : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 4 / 21
ELECTRICAL SYMBOLS
ELECTRICAL NOTES:-

G
IN
CEILING FAN CALLING BELL 2.20M

IL
1. THIS ELECTRICAL PLAN SHALL BE READ

CE
TWO GANG
WITH ARCHITECTURAL DRAWINGS AND

G
IN
CHANDELIER SWITCH TWO 2.20M

IL
CE
WAY
SPECIFICATIONS.

NG
FLUORESCENT BOX

I
MIRROR LIGHT 2.20M

IL
2. ALL ELECTRICAL WORKS SHALL BE CARRIED DOUBLE TUBE LIGHT

CE
G
OUT AS PER APPROVED DRAWING TO FLUORESCENT BOX

IN
FAN REGULATOR 1.50M

IL
DOUBLE TUBE LIGHT

CE
CONFORM WITH THE LATEST OMAN
FLUORESCENT BOX ONE GANG

G
1.50M

IN
ELECTRICAL STANDARDS AND SINGLE TUBE LIGHT

IL
SWITCH

CE
REGULATIONS. CEILING LIGHT TWO GANG
1.50M
SWITCH
3. SEPARATE D.B. SHALL BE USED FOR EACH
SPEAKER AC SOCKET & 1.50M
FLOOR AND ONE ADDITIONAL D.B FOR SWITCH
CAMERA 3.40M TV SOCKET & 1.50M
EXTERNAL WORKS SUCH AS SERVANT SWITCH
ROOM,PENT HOUSE, TERRACE FLOOR, WATER HEATER
WINDOW TYPE AC 2.20M SWITCH 1.50M
COMPOUND WALL LIGHTS AND PUMPS ETC.,
SPLIT UNIT AC 2.20M COOKER 0.80M
EL 4. D.B'S SHALL BE INSTALLED IN COMMON
EL
WALL LIGHT 2.20M T.V POSITION 0.50M
HALL.
EXHAUST FAN 2.20M TELE PHONE 0.50M
5. ALL WIRING SHALL BE WITH COLORS CODE
AND LABELED IN SERIAL NUMBER. WATER HEATER 2.20M INTERCOM 0.50M
6. ALL LOAD MUST BE BALANCED. 13 AMP SOCKET BELL PUSH Ext-
1.50M
7. EACH D.B SHALL BE EARTH IN SEPARATE AND SWITCH BUTTON Wall
MAIN DISTRIBUTION 2.20M
EARTH PIT. BOARD
1.50M SPOT LIGHT

8. ALL EARTH PITS SHALL BE PROVIDED WITH KEY HOLDER 2.20M SWITCH BOARD 2.20M

C.I COVER TO FACILITATE PERIODIC CEILING 6A SWITCH


2.20M SOCKET OUTLET 2.20M
PENDENT FOR CHIMNEY
INSPECTION.

MDB
FOOT LAMP AT 3PIN 166 SWITCH
9. METER BOARD SHALL BE INSTALLED 2.20M SOCKET OUTLET
9"LVL
AT 1800 mm
WATER PROOF &

HDU
OUTSIDE OF THE HOUSE, PREFERABLY NEAR
WEATHER PROOF EMERGENCY CEILING ROSE
EL
THE ENTRANCE GATE PROJECTING INSIDE LIGHT
SOCKET (TYP)
THE COMPOUND WALL AS DETAILED IN THE WIFI - POINT
EL
DRAWING WITH VIEWING GLASS OUT SIDE.
SPECIAL NOTES OF HIGH RISE BUILDINGS:
10. HIGH RISE BUILDINGS SHALL BE PROVIDED
EL WITH LIGHTNING CONDUCTOR WITH
SEPARATE EARTH AS BRIEFED IN OES -4
(CLAUSE 8.19).
11. A SEPARATE ELECTRICAL ROOM SHALL BE
EL
PROVIDED AND EQUIPPED WITH A/C UNIT,
LAMP AND A RUBBER MAT IN FRONT OF THE
MAIN PANEL BOARD WITH SUFFICIENT
WORKING SPACE.
12. TWO SETS OF LINE DIAGRAM OF LOAD
DISTRIBUTION HAS TO BE SUBMITTED IN C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
ADVANCE FOR APPROVAL. No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
13. NEW APPROVED LINE DIAGRAM SHALL BE
of the Muruj Engineering consultancy office.
PRODUCED AT THE TIME OF INSPECTION. NO: DATE REVISION BY: APP:

S
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
MURUJ
F.F.ELECTRICAL PLAN Engineering Consultancy & Services

UJ E
MU R
SCALE 1:100 ( ALL DIM ARE IN CM'S)
Al Kamil
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI


PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TITLE : -
G.F ELECTRICAL PLAN
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 5 / 21
SCHEMATIC DIAGRAM SHOWING A THREE PHASE
MAIN SUPPLY FROM
ELECTRICAL SERVICE ( TYP )
MHEW SOURCE
4C 35 SQMM/XLPE/SWA/PVC CU CABLE.
+ 1 C 35 SQMM EARTH CABLE

1. THE SCHEMATIC DIAGRAM HERE SHOWN IS FOR INDICATING BASIC


METHOD OF DISTRIBUTION AND TYPE OF EQUIPMENTS / ELECTRICAL
ACCESSORIES ONLY
2. THE MCCBs, CABLE, ISOLATORS ARE RATED AS PER MANUFACTURERS
100 A
3 PHASE
RECOMMENDATIONS AND THESE ARE CONSIDERED TO BE THE MINIMUM
100 A KWH METER
TP MCCB OUT REQUIREMENTS.
MAIN IN FUSE
3. THE CLIENT / CONTRACTOR SHALL BE LIABLE TO TAKE INTO
SPARE CONSIDERATION, THE CHANGES OF LOCAL AUTHORITY REGULATIONS
FROM TIME TO TIME WHEN PROVIDING SHOP DRAWINGS FOR
CONSULTANTS APPROVAL. NO CLAIM IN THIS REGARD SHALL BE
MAIN PANEL BOARD WITH
METAL CABINET AS LOCATED 4C 35 SQMM/XLPE/SWA/PVC CU CABLE. CONSIDERED
IN SITE PLAN
+ 1 C 35 SQMM PVC CU. CABLE 4. ANY CHANGES IN REQUIREMENTS BY CLIENT /CONTRACTOR EXCEEDING
100ATP THE SANCTIONED LOAD LIMIT WILL ALTER THE BASIC PROVISIONS , AND
MCCB
EARTH OUT. HENCE SUCH CHANCES IF ANY SHALL BE PROPOSED WITH SHOP
PIT DRAWINGS FOR CONSULTANTS APPROVAL NO CLAIM IN THIS REGARD
SHALL BE CONSIDERED.

DB NO./REF. : MDB - GF IN COMMING CABLE: 4C 35 SQMM/XLPE/SWA/ PVC/CU CABLE


TYPE : 100 AMPS 12 WAY TPN WITH ISOLATER EARTH CABLE : 1 C 35 SQMM /PVC/CU CABLE
FEEDING CABLES : LIGHT& FANS - 1.5 sqmm
FEEDING TO : LIGHT & POWER POINTS GROUND FLOOR WEATHER PROOF
A/C DOMESTIC < 1.5 T , 20 A SOCKETS - 4.0 sqmm GATE LIGHT
SUPPLY FROM : PANEL BOARD A/C MOSQUE/PUBLIC PLACES >2.0 T, 32 A SOCKETS - 6.0 sqmm
RATING NO. OF LOAD PHASE LOAD IN KW
WAY POLE
(AMPS)
CABLE SIZE LOAD DISTRIBUTION TO POINTS (KW) REMARKS
R Y B CONCRETE SLAB 100 MM TK
R1 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 1 & BATH 2.5 PROJECTED IN SIDE

1 Y1 16 A 3X2.5 SQMM SOCKETS BED ROOM - 1 & BATH 0.5


BELL PUSH BUTTON
B1 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 1 & BATH 0.9
R2 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 2 & BATH 2.5
2 Y2 16 A 3X2.5 SQMM SOCKETS BED ROOM - 2 & BATH 0.5 WIRE MESH

B2 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 2 & BATH 0.9 VIEWING GLASS
GATE (G2)
R3 30 A 3X6.0 SQMM AIR CONDITIONER FAMILY HALL 2.5
3 Y3 16 A 3X2.5 SQMM SOCKETS FAMILY HALL 0.5
PANEL BOARD ( TYP )
B3 10 A 3X1.5 SQMM LIGHTS & FANS FAMILY HALL 1.0
R4 30 A 3X6.0 SQMM AIR CONDITIONER KITCHEN & STORE 2.5
4 Y4 16 A 3X2.5 SQMM SOCKETS KITCHEN & STORE 0.5
UPVC CABLE DUCT UPVC CABLE DUCT
B4 10 A 3X1.5 SQMM LIGHTS & FANS KITCHEN & STORE 0.8 CABLE FROM POLE CABLE TO MAIN BUILDING

R5 20 A 3X4.0 SQMM WATER HEATER KITCHEN 1.5


5 Y5 20 A 3X4.0 SQMM WATER HEATER BED ROOM - 1 & BATH 1.5

30CM
B5 20 A 3X4.0 SQMM WATER HEATER BED ROOM - 2 & BATH 1.5 CABLE TO M.D.B
IN SIDE
R6 SPARE

6
Y6 40 A 3X6.0 SQMM COCKER KITCHEN 4.0 G1 C COPYRIGHT : -
B6 10 A 3X1.5 SQMM LIGHTS & FANS PASSAGE 0.6
OUT SIDE This drawing is protected by copyright. All rights are reserved.
R7 30 A 3X6.0 SQMM AIR CONDITIONER G.MAJLIS & BATH 2.5 PANEL BOARD
No part of this drawing may in any form or by any means be reproduced,
BOUNDARY WALL
GATE 'G1'
7 Y7 16 A 3X2.5 SQMM SOCKETS G.MAJLIS & BATH 0.5 published, broadcast or transmitted without the prior written permission
B7 10 A 3X1.5 SQMM LIGHTS & FANS G.MAJLIS & BATH of the Muruj Engineering consultancy office.
1.0
ELECTRICAL PANEL BOARD DETAIL
R8 30 A 3X6.0 SQMM AIR CONDITIONER M.BED ROOM & BATH 2.5 NO: DATE REVISION BY: APP:
8 Y8 16 A 3X2.5 SQMM SOCKETS M.BED ROOM & BATH 0.5
B8 10 A 3X1.5 SQMM LIGHTS & FANS M.BED ROOM & BATH 1.0
R9 SPARE
9 Y9 20 A 3X4.0 SQMM WATER HEATER G.MAJLIS & BATH 1.5
S
V I CE
SER
B9 20 A 3X4.0 SQMM WATER HEATER

&
M.BED ROOM & BATH 1.5

NY
NG I NNN ER I NG CON S UL TA
R10 SPARE
10 Y10 SPARE
B10
R11
SPARE MURUJ
SPARE
Engineering Consultancy & Services

UJ E
11 Y11 SPARE

MU R
B11
Al Kamil
SPARE
WhatsApp:- 90 90 45 60
R12 SPARE
Email : - murujalkamil@gmail.com
12 Y12 SPARE
B12 SPARE
CLIENT NAME :
TOTAL PHASE LOAD 16.5 10.0 9.2 Mr . TAAEER BADAR TAAEER AL RASBI
TOTAL LOAD 35.70 KW
PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH

EARTH TITLE : -
PIT GRAND TOTAL = 35.70 KW ELECTRICAL LOAD CALCULATION
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 6 / 21
SCHEMATIC DIAGRAM SHOWING A THREE PHASE
MAIN SUPPLY FROM ELECTRICAL SERVICE ( TYP )
MHEW SOURCE
4C 35 SQMM/XLPE/SWA/PVC CU CABLE.
+ 1 C 35 SQMM EARTH CABLE

1. THE SCHEMATIC DIAGRAM HERE SHOWN IS FOR INDICATING BASIC


METHOD OF DISTRIBUTION AND TYPE OF EQUIPMENTS / ELECTRICAL
ACCESSORIES ONLY
2. THE MCCBs, CABLE, ISOLATORS ARE RATED AS PER MANUFACTURERS
100 A RECOMMENDATIONS AND THESE ARE CONSIDERED TO BE THE MINIMUM
3 PHASE
100 A KWH METER
TP MCCB OUT REQUIREMENTS.
MAIN IN FUSE
3. THE CLIENT / CONTRACTOR SHALL BE LIABLE TO TAKE INTO

SPARE
CONSIDERATION, THE CHANGES OF LOCAL AUTHORITY REGULATIONS
FROM TIME TO TIME WHEN PROVIDING SHOP DRAWINGS FOR
CONSULTANTS APPROVAL. NO CLAIM IN THIS REGARD SHALL BE
MAIN PANEL BOARD WITH CONSIDERED
METAL CABINET AS LOCATED 4C 35 SQMM/XLPE/SWA/PVC CU CABLE.
IN SITE PLAN 4. ANY CHANGES IN REQUIREMENTS BY CLIENT /CONTRACTOR EXCEEDING
+ 1 C 35 SQMM PVC CU. CABLE
THE SANCTIONED LOAD LIMIT WILL ALTER THE BASIC PROVISIONS , AND
100ATP
MCCB HENCE SUCH CHANCES IF ANY SHALL BE PROPOSED WITH SHOP
EARTH OUT.
DRAWINGS FOR CONSULTANTS APPROVAL NO CLAIM IN THIS REGARD
PIT
SHALL BE CONSIDERED.

DB NO./REF. : MDB - GF IN COMMING CABLE: 4C 35 SQMM/XLPE/SWA/ PVC/CU CABLE


TYPE : 100 AMPS 12 WAY TPN WITH ISOLATER EARTH CABLE : 1 C 35 SQMM /PVC/CU CABLE
WEATHER PROOF
FEEDING CABLES : LIGHT& FANS - 1.5 sqmm GATE LIGHT
FEEDING TO : LIGHT & POWER POINTS GROUND FLOOR
A/C DOMESTIC < 1.5 T , 20 A SOCKETS - 4.0 sqmm
SUPPLY FROM : PANEL BOARD A/C MOSQUE/PUBLIC PLACES >2.0 T, 32 A SOCKETS - 6.0 sqmm
RATING NO. OF LOAD PHASE LOAD IN KW CONCRETE SLAB 100 MM TK
WAY POLE
(AMPS)
CABLE SIZE LOAD DISTRIBUTION TO POINTS (KW) REMARKS PROJECTED IN SIDE
R Y B
R1 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 1 & BATH 2.5 BELL PUSH BUTTON

1 Y1 16 A 3X2.5 SQMM SOCKETS BED ROOM - 1 & BATH 0.5


B1 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 1 & BATH 0.9
WIRE MESH
R2 SPARE VIEWING GLASS

2 Y2 SPARE GATE (G2)


B2 SPARE
PANEL BOARD ( TYP )
R3 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 1 & BATH 2.5
3 Y3 16 A 3X2.5 SQMM SOCKETS BED ROOM - 1 & BATH 0.5
B3 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 1 & BATH 1.0
UPVC CABLE DUCT UPVC CABLE DUCT
R4 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 1 & BATH 2.5 CABLE FROM POLE CABLE TO MAIN BUILDING

4 Y4 16 A 3X2.5 SQMM SOCKETS BED ROOM - 1 & BATH 0.5


B4 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 1 & BATH 0.8

30CM
CABLE TO M.D.B
R5 20 A 3X4.0 SQMM WATER HEATER 1.5
IN SIDE
5 Y5 20 A 3X4.0 SQMM WATER HEATER BED ROOM - 1 & BATH 1.5
B5 SPARE G1 C COPYRIGHT : -
R6 SPARE OUT SIDE This drawing is protected by copyright. All rights are reserved.
PANEL BOARD
Y6 40 A 3X6.0 SQMM BOUNDARY WALL No part of this drawing may in any form or by any means be reproduced,
GATE 'G1'
6 published, broadcast or transmitted without the prior written permission
B6 10 A 3X1.5 SQMM LIGHTS & FANS PASSAGE 0.6
of the Muruj Engineering consultancy office.
R7 30 A 3X6.0 SQMM AIR CONDITIONER G.MAJLIS & BATH 2.5 ELECTRICAL PANEL BOARD DETAIL
NO: DATE REVISION BY: APP:
7 Y7 16 A 3X2.5 SQMM SOCKETS G.MAJLIS & BATH 0.5
B7 10 A 3X1.5 SQMM LIGHTS & FANS G.MAJLIS & BATH 1.0
R8 SPARE
8 Y8 SPARE S
V I CE
SER
B8 SPARE

&
NY
NG I NNN ER I NG CON S UL TA
R9 20 A 3X4.0 SQMM WATER HEATER BED ROOM - 2 1.5
9 Y9 20 A 3X4.0 SQMM WATER HEATER G.MAJLIS & BATH 1.5
B9 10 A 3X1.5 SQMM LIGHTS EXTERNAL SIDE 1.5 MURUJ
R10 30 A 3X6.0 SQMM AIR CONDITIONER BED ROOM - 2 2.5
Engineering Consultancy & Services

UJ E
10 Y10 16 A 3X2.5 SQMM SOCKETS BED ROOM - 2 0.5

MU R
Al Kamil
B10 10 A 3X1.5 SQMM LIGHTS & FANS BED ROOM - 2 0.7 WhatsApp:- 90 90 45 60
R11 SPARE Email : - murujalkamil@gmail.com
11 Y11 SPARE By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023 CLIENT NAME :
B11 SPARE
R12 SPARE Mr . TAAEER BADAR TAAEER AL RASBI
12 Y12 SPARE
PLOT NO : - LOCATION : - J . B .BUALI,
B12 SPARE
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TOTAL PHASE LOAD 15.5 9.5 6.5
TITLE : -
TOTAL LOAD 31.50 KW ELECTRICAL LOAD CALCULATION
DESIGNED : - JOB NO : -

EARTH
GROUND FLOOR TOTAL LOAD = 31.50 KW GRAND TOTAL = G.F + F.F = 35.70 + 31.50 = 67.00 KW CHECKED : -
Hari
SCALE : -
0083 / MECS

PIT Ram 1 : 100 (A3)

CAD DESIGNER : - DATE : -


Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 7 / 21
FIRE RESISTING PLAN SYMBOLS
EMERGENCY FIRE EXTINGUISHERS
EL LIGHTING POINT AFF FOAM TYPE
FIRE EXTINGUISHERS
FB FIRE BLANKET CO2 CARBOX DIOXIDE(5KG)
FIRE HOSE REEL
EXIT DIRECTION
HR
WITH DOUBLE CABINET E SIGN
(19mm x 45.00 m long )
GAS DETECTOR FIRE ALARM
GD
CALL POINT(Break glass)
SMOKE DETECTOR AUDIBLE WARNING
DS (battery type) DEVICE(fire alarm bell)

IP FIRE CONTROL PANEL GD GAS DETECTOR

DH HEAT DETECTOR
EL FIRE ALARM (battery type)

WATER SPRINGER SMOKE EXTRACT FAN

FIR EXITNGUISHERS - 9 LTS


H FIRE HYDRANT BCF BCF TYPE
80
DR DRYPSER OUTLET FR - 60 FIRE RESISTING DOOR ( 60 Minutes )
CO²
140

( 2Kg)
FB DH
EL
140W X 80L X 100 H

GD
CYLINDER ROOM

(battery)
GAS

50 700 50

50
EXITINGUISHER
IN ARABIC

750
AND ENGLISH

50
FRONT VIEW

HOSE
REEL

2kg.CO2
AFF
C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
VIEW WITH DOOR OPEN of the Muruj Engineering consultancy office.
NO: DATE REVISION BY: APP:

S
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
MURUJ
FIRE FIGHTING PLAN Engineering Consultancy & Services

UJ E
MU R
Al Kamil
SCALE 1:100 ( ALL DIM ARE IN CM'S)

700
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
AFF CO2
CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI


PLOT NO : - LOCATION : - J . B .BUALI,

300
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TITLE : -
FIRE FIGHTING PLAN
DESIGNED : - JOB NO : -
FINISHED FLOOR LEVEL
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
FIRE EXTINGUISHER CABINET CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 8 / 21
SANITARY NOTES:- SANITARY FITTINGS SYMBOLS
1. ALL WATER SUPPLY AND DRAINAGE PIPES BATH TUB WASH BASIN
SHALL BE CONCEALED INSIDE OF BUILDING. WASH BASIN AND
SHOWER TUB
2. COPPER PIPES SHALL BE USED FOR HOT MIRROR LIGHT
ARABIAN TYPE WESTERN TYPE
WATER LINE WITH APPROPRIATE WATER CLOSET WATER CLOSET

To Septic Tank
CONNECTION FITTINGS, AS PER F.T
FLOOR TRAP STAINLESS STEEL
SINK
MANUFACTURERS INSTRUCTIONS.
GT GULLY TRAP OVEN
3. ALL BATH ROOMS / TOILETS SETS SHALL
COMPRISE OF THE UNITS SHOWN ON THE MH MAN HOLE COVER WATER HEATER

DRAWING AND OTHER ACCESSORIES SUCH AS EXHAUST FAN


150 mm DIA - UPVC PIPE 150 mm DIA - UPVC PIPE 150 mm DIA - UPVC PIPE
MH Slope 1 : 100 MH Slope 1 : 100 MH Slope 1 : 100 MH TAPS , VALVES, ANAL SPRAY , SOAP TRAY,
DRAINAGE CONNECTION
PAPER ROLL HOLDER , MIRROR UNIT ETC.,
1 FROM WASH BASIN, BIDET 36 mm Ø
4. UNLESS OTHERWISE SPECIFIED 600 GALLON
GT GT CAPACITY POLYETHYLENE WATER TANK 2 FROM SINK, BATH AND SHOWER 42 mm Ø
150 mm DIA - UPVC PIPE

SHALL BE MOUNTED ON THE TERRACE WITH 3 FROM FLOOR DROP TO GULLY TRAP 55 mm Ø

NECESSARY FITTINGS, ISOLATION VALVE, 4 FROM WATER CLOSET TO MANHOLE 110 mm Ø


Slope 1 : 100

F.T

FLOAT STOP VALVE AND MOUNTING 5 PIPE FOR SEWER LINE (UPVC) 150 mm Ø

F.T
SADDLES, OVERFLOW OUTLET, WASH WATER 6 WASTE WATER PIPE (UPVC) 100 mm Ø
OUTLET ETC., 7 VENT PIPE AND VENT STACK (UPVC) 100 mm Ø
5. HOLDING TANK AND SEPTIC TANK SHALL BE
8 RAIN WATER PIPE (UPVC) 100 mm Ø
CONSTRUCTED WITH SOLID/ REINFORCED
MH
BLOCK WORK/ RCC.
6. ALL THE ST & HT WALLS CONSTRUCTED
WITH BLOCK WORK SHALL BE RENDERED TO
MAKE WATER PROOF PLASTER.
150 mm DIA - UPVC PIPE

7. THE SEWAGE LINE FROM WATER CLOSET TO


SEPTIC TANK SHALL BE MADE LEAKAGE
PROOF.
Slope 1 : 100

8. SEPARATE DISPOSAL LINES MUST BE MADE


FOR SEWAGE FROM WATER CLOSET AND
WASTE WATER DISPOSAL.
GT
F.T 9. MAINTAIN A SLOPE OF 1:100 FOR SEWAGE LINE.
10. THE DISTANCE BETWEEN MANHOLES SHALL
MH NOT EXCEED 20m.
GT F.T

11. COMFORTABLY PROVIDE MANHOLES AT


JUNCTIONS AND CORNER, OVER PROPERLY
COMPACTED SOIL BASE.
12. ALL THE MAN HOLE COVERS SHALL BE OF
DOUBLE SEAL/ MEDIUM DUTY CAST IRON.
13. ALL THE A/C DRAIN WATER SHALL BE
COLLECTED WITHOUT LEAKAGE AND C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
DISPOSED TO A SOAK PIT(REFER SOAK PIT No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
DETAILS IN GENERAL SHEET).
of the Muruj Engineering consultancy office.
14. USE 12 OR 18mm LEAKAGE FREE CONDUIT FOR NO: DATE REVISION BY: APP:

A/C DRAIN WATER.

S
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
MURUJ
Engineering Consultancy & Services

UJ E
MU R
Al Kamil
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI

SANITARY PLAN PLOT NO : -


6 - 15 - 087 - 05 - 030
LOCATION : - J . B .BUALI,
AL OLA P/A NORTH
SCALE 1:100 ( ALL DIM ARE IN CM'S) TITLE : -
G.F SANITARY PLAN
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 9 / 21
SANITARY NOTES:- SANITARY FITTINGS SYMBOLS
1. ALL WATER SUPPLY AND DRAINAGE PIPES BATH TUB WASH BASIN
SHALL BE CONCEALED INSIDE OF BUILDING. WASH BASIN AND
SHOWER TUB
2. COPPER PIPES SHALL BE USED FOR HOT MIRROR LIGHT
ARABIAN TYPE WESTERN TYPE
WATER LINE WITH APPROPRIATE WATER CLOSET WATER CLOSET
CONNECTION FITTINGS, AS PER F.T
FLOOR TRAP STAINLESS STEEL
SINK
MANUFACTURERS INSTRUCTIONS.
GT GULLY TRAP OVEN
3. ALL BATH ROOMS / TOILETS SETS SHALL
4"Ø UPVC VENTILATION PIPE 4"Ø UPVC VENTILATION PIPE
TO PARAPET TOP LEVEL TO PARAPET TOP LEVEL COMPRISE OF THE UNITS SHOWN ON THE MH MAN HOLE COVER WATER HEATER

TO M H TO M H
DRAWING AND OTHER ACCESSORIES SUCH AS EXHAUST FAN
TAPS , VALVES, ANAL SPRAY , SOAP TRAY,
DRAINAGE CONNECTION
PAPER ROLL HOLDER , MIRROR UNIT ETC.,
F.T
F.T
1 FROM WASH BASIN, BIDET 36 mm Ø
4. UNLESS OTHERWISE SPECIFIED 600 GALLON
2 FROM SINK, BATH AND SHOWER 42 mm Ø
CAPACITY POLYETHYLENE WATER TANK
SHALL BE MOUNTED ON THE TERRACE WITH 3 FROM FLOOR DROP TO GULLY TRAP 55 mm Ø

NECESSARY FITTINGS, ISOLATION VALVE, 4 FROM WATER CLOSET TO MANHOLE 110 mm Ø


FLOAT STOP VALVE AND MOUNTING 5 PIPE FOR SEWER LINE (UPVC) 150 mm Ø
SADDLES, OVERFLOW OUTLET, WASH WATER 6 WASTE WATER PIPE (UPVC) 100 mm Ø
OUTLET ETC., 7 VENT PIPE AND VENT STACK (UPVC) 100 mm Ø
5. HOLDING TANK AND SEPTIC TANK SHALL BE
8 RAIN WATER PIPE (UPVC) 100 mm Ø
CONSTRUCTED WITH SOLID/ REINFORCED
BLOCK WORK/ RCC.
F.T

6. ALL THE ST & HT WALLS CONSTRUCTED


WITH BLOCK WORK SHALL BE RENDERED TO
4"Ø UPVC VENTILATION PIPE

MAKE WATER PROOF PLASTER.


TO PARAPET TOP LEVEL

7. THE SEWAGE LINE FROM WATER CLOSET TO


SEPTIC TANK SHALL BE MADE LEAKAGE
PROOF.
TO M H

8. SEPARATE DISPOSAL LINES MUST BE MADE


F.T FOR SEWAGE FROM WATER CLOSET AND
WASTE WATER DISPOSAL.
9. MAINTAIN A SLOPE OF 1:100 FOR SEWAGE LINE.
10. THE DISTANCE BETWEEN MANHOLES SHALL
NOT EXCEED 20m.
11. COMFORTABLY PROVIDE MANHOLES AT
JUNCTIONS AND CORNER, OVER PROPERLY
COMPACTED SOIL BASE.
12. ALL THE MAN HOLE COVERS SHALL BE OF
DOUBLE SEAL/ MEDIUM DUTY CAST IRON.
13. ALL THE A/C DRAIN WATER SHALL BE
COLLECTED WITHOUT LEAKAGE AND C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
DISPOSED TO A SOAK PIT(REFER SOAK PIT No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
DETAILS IN GENERAL SHEET).
of the Muruj Engineering consultancy office.
14. USE 12 OR 18mm LEAKAGE FREE CONDUIT FOR NO: DATE REVISION BY: APP:

A/C DRAIN WATER.

S
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
F.F.SANITARY PLAN
SCALE 1:100 ( ALL DIM ARE IN CM'S)
MURUJ
Engineering Consultancy & Services

UJ E
MU R
Al Kamil
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI


PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TITLE : -
G.F SANITARY PLAN
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CAD DESIGNER : - DATE : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 10 / 21
NOTES:-
1. WATER PROOFING WORK SHALL BE DONE
FOR ALL THE SUNKEN SLABS BEFORE THE
COMMENCEMENT OF PLUMBING WORKS.

( EXTENDED TO BOUNDARY WALL)


P.P.R. PIPE WITH GATE VALVE
BROWSER FEEDING POINT OF 36MM DIA.
2. ROOF WATER PROOFING SHALL BE DONE BY

( e en e
MAIN LINE WITH CONTROL VALVE
25 mm DIA. HIGH P.P.R. PIPE FROM
EMPLOYING SPECIALIZED TEAM OF PEOPLE

WATER TANK
600 GALLON POLYETHYLENE
EXTERNAL ELEVATION EXTERNAL ELEVATION
IN THIS FIELD.

OVER FLOW OUTLET PIPE


IN SIDE IN SIDE
3. ALL THE WATER PROOFING MEMBRANE

un ar
GRC
SHALL BE PROTECTED PROPERLY , NO
GRC
Drainage pipe Drainage pipe PUNCHING OF HOLES,SCRATCHING OR

a )
OUT SIDE OUT SIDE TEARING ON THE TOP SURFACE.
PLAN PLAN
TYPE 2
TYPE 1
4. NO WHEELING OR PULLING OF HEAVY
RAIN WATER RAIN WATER

10
RAIN WATER MATERIALS OVER THE TOP SURFACE OF
U.P.V.C PIPE (TYP) U.P.V.C PIPE (TYP)
U.P.V.C PIPE (TYP) WATER PROOFING MEMBRANE.
EXTERNAL ELEVATION EXTERNAL ELEVATION
IN SIDE IN SIDE
A . C UNIT A . C UNIT
PIPE
PIPE

10
Drainage pipe
Drainage pipe

WASH GRC
GRC
OUT SIDE OUT SIDE

RIDGE LINE
CENTRAL ANTENNA PLAN PLAN

PLAT FORM
200 mm HIGH SOLID
CONTROL VALVE
TYPE 1 TYPE 2

HOLLOW BLOCK WORK PARAPET

DN WATER PROOFING RAISED 200mm ABOVE FILLET TOP


ON PARAPET,TERMINATED IN 20x20mm GROOVE AND
FILLED WITH MASTIC SEALANT
SOLAR REFLECTIVE MEMBRANE 4MM TK
WHITE CEMENT TILES PACKED IN CM 1:4
WATER PROOFING MEMBRANE 4 MM THICK
OVER 2 COATS OF HOT BITUMEN
CEMENT SAND SCREED TO SLOPE

12 X 50MM EXPANSION JOINT FILLED WITH


POLYSULPHIDE SEALANT
RIDGE LINE
RIDGE LINE
10 DETAIL OF WATER PROOFING
SCALE 1:100 ( ALL DIM ARE IN CM'S)
U.P.V.C PIPE (TYP)
RAIN WATER

20 x 20 MM GROVE FILLED WITH MASTIC SEALANT


RIDGE LINE

CEMENT SAND CROUTING AROUND PVC PIPE


METAL GRATING 150X150 MM (TYP)
SOLAR REFLECTIVE MEMBRANE 4MM TK
WHITE CEMENT TILES PACKED IN CM 1:4
WATER PROOFING MEMBRANE 4 MM THICK
OVER 2 COATS OF HOT BITUMEN C COPYRIGHT : -
CEMENT SAND SCREED TO SLOPE This drawing is protected by copyright. All rights are reserved.
No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
10 of the Muruj Engineering consultancy office.

CONCRETE ROOF SLAB NO: DATE REVISION BY: APP:


25 CEMENT SAND GROUTING AROUND PVC PIPE

S
V I CE
25

SER

&
NY
100mm uPVC PIPE CLAMPED 1m c/c

NG I NNN ER I NG CON S UL TA
MURUJ
Engineering Consultancy & Services

UJ E
TERRACE PLAN

MU R
DETAILS OF WATER PROOFING AT RAIN WATER DISPOSAL PIPE
Al Kamil
SCALE 1:100 ( ALL DIM ARE IN CM'S) WhatsApp:- 90 90 45 60
SCALE 1:100 ( ALL DIM ARE IN CM'S) Email : - murujalkamil@gmail.com
CLIENT NAME :

100mm Ø UPVC Mr . TAAEER BADAR TAAEER AL RASBI


RAIN PIPE X

BUILDING
PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
PCC TITLE : -
TERRACE PLAN
FGL
DESIGNED : - JOB NO : -
Hari 0083 / MECS
X CHECKED : - SCALE : -
SECTION X-X SPLASH BLOCK Ram 1 : 100 (A3)
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
UPVC RAIN WATER PIPE CONNECTION AT GROUND DETAILS CAD DESIGNER : - DATE : -
SCALE 1:100 ( ALL DIM ARE IN CM'S)
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 11 / 21
CONCRETE CONCRETE EXTERNAL FINISHES PLASTER PRIMER

PROJECTION PROJECTION SCHEDULE PAINT TILE


PLASTER DESIGN CONCRETE
15
SEE DETAILS
PROJECTION DESCRIPTION

15

30
1. 16 mm THICK CEMENT MORTAR PLASTER FINISH.
2. 32mm THICK CEMENT MORTAR PLASTER MAKING

150

150
DESIGNED CARVING WORK.
3. 20mm WIDE GROOVE IN 16mm THICK PLASTER.
4. 50mm WIDE RECESS IN 16mm THICK PLASTER FOR
8mm DEEP.
5. 100mm WIDE RECESS IN 16mm THICK PLASTER FOR
340

340
8mm DEEP.

200

200
6. ONE COAT OF ALKALI RESISTANT GOOD
QUALITY ACRYLIC PRIMER.
950

950
7. TWO COATS OF EXTERIOR MATT EMULSION
OVER PRIMER COAT.

180

180
800

800
8. TWO COATS OF TEXTURE PAINT OVER PRIMER
COAT.
9. NON-GLOSY / MATT FINISHED CERAMIC TILED
380

380
FINISHING.
200

200
10. SAND STONE TILED FINISHING.

NOTE:-
· DO NOT USE NORMAL GLAZED CERAMIC
TILES FOR ENTRANCE STEPS AND STAIRCASE.
130

130
· ALL THE EXTERNAL FINISHES SHALL BE
80

80
F.G.L F.G.L APPROVED BY THE ENGINEER.

20
20 35 35

FRONT ELEVATION
SCALE 1:100 ( ALL DIM ARE IN CM'S)

CONCRETE CONCRETE CONCRETE


PLASTER DESIGN PROJECTION
PROJECTION PROJECTION By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
150

150
C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
1 6
8 * No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
1 6
8 * of the Muruj Engineering consultancy office.
1 6
8 *
NO: DATE REVISION BY: APP:
340

340
120

S
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
950

950

MURUJ
260
800

800

1 6
Engineering Consultancy & Services

UJ E
8 *

MU R
Al Kamil
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
380

380

CLIENT NAME :
120

120

1 6
8 * Mr . TAAEER BADAR TAAEER AL RASBI
PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
180

180

TITLE : -
ELEVATION
80

80

F.G.L F.G.L DESIGNED : - JOB NO : -


Hari 0083 / MECS
CHECKED : - SCALE : -
40 Ram 1 : 100 (A3)
40 REAR SIDE ELEVATION 40
CAD DESIGNER : - DATE : -
SCALE 1:100 ( ALL DIM ARE IN CM'S) Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 12 / 21
CONCRETE
EXTERNAL FINISHES PLASTER PRIMER
SEE DETAILS
PROJECTION
SCHEDULE PAINT TILE
CONCRETE LED Strip lights
PLASTER DESIGN

15
PROJECTION

30
DESCRIPTION

15
1. 16 mm THICK CEMENT MORTAR PLASTER FINISH.

150

150
2. 32mm THICK CEMENT MORTAR PLASTER MAKING
1 6
8 * DESIGNED CARVING WORK.
3. 20mm WIDE GROOVE IN 16mm THICK PLASTER.

1 6
4. 50mm WIDE RECESS IN 16mm THICK PLASTER FOR
1 6
8 * 8 *
8mm DEEP.

120
5. 100mm WIDE RECESS IN 16mm THICK PLASTER FOR
340

340
8mm DEEP.
6. ONE COAT OF ALKALI RESISTANT GOOD
QUALITY ACRYLIC PRIMER.
950

950
15

260
7. TWO COATS OF EXTERIOR MATT EMULSION
OVER PRIMER COAT.
800

800
15
8. TWO COATS OF TEXTURE PAINT OVER PRIMER
10 COAT.
9. NON-GLOSY / MATT FINISHED CERAMIC TILED
380

380
120
320

FINISHING.
10. SAND STONE TILED FINISHING.
1 6
8 *

NOTE:-

210
· DO NOT USE NORMAL GLAZED CERAMIC
TILES FOR ENTRANCE STEPS AND STAIRCASE.
80

80
· ALL THE EXTERNAL FINISHES SHALL BE
F.G.L F.G.L APPROVED BY THE ENGINEER.

40 40
PLASTER DESIGN
PLASTER DESIGN
RIGHT SIDE ELEVATION
SCALE 1:100 ( ALL DIM ARE IN CM'S)

CONCRETE PLASTER DESIGN CONCRETE


PROJECTION PROJECTION
CONCRETE
PROJECTION
150

150
1 6
8 *

1 6
8 *
1 6
8 *
1 6
8 * C COPYRIGHT : -
1 6
This drawing is protected by copyright. All rights are reserved.
120

8 *
340

340
No part of this drawing may in any form or by any means be reproduced,
published, broadcast or transmitted without the prior written permission
of the Muruj Engineering consultancy office.
NO: DATE REVISION BY: APP:
950

950
260

S
800

800
V I CE
SER

&
NY
NG I NNN ER I NG CON S UL TA
MURUJ
380

380
120

120

Engineering Consultancy & Services

UJ E
1 6

MU R
8 * Al Kamil
WhatsApp:- 90 90 45 60
Email : - murujalkamil@gmail.com
210

210

CLIENT NAME :

Mr . TAAEER BADAR TAAEER AL RASBI


80

80

F.G.L F.G.L PLOT NO : - LOCATION : - J . B .BUALI,


6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH

40 40 TITLE : -
40 PLASTER DESIGN ELEVATION
PLASTER DESIGN
DESIGNED : - JOB NO : -
Hari 0083 / MECS
LEFT SIDE ELEVATION By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023
CHECKED : -
Ram
SCALE : -
1 : 100 (A3)
SCALE 1:100 ( ALL DIM ARE IN CM'S) DATE : -
CAD DESIGNER : -
Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 13 / 21
NOTE : IRONMONGERY:
1. FOR MAIN DOOR, PROVIDE MORTISE LOCK
PROVIDE A BEAM ( 20 X 20 ) @ WINDOWS TOP & BOTTOM
WITH DOUBLE CYLINDER SASH (CYLINDER
TO BE CONNECT WITH COLUMN TO COLUMN LENGTH TO SUIT SHUTTER THICKNESS)
LED Strip lights INCLUDING POLISHED BRASS LEVER HANDLE
C CRETE
30 30 R ECTI
SET AND 3 NOS OF KEYS,PROVIDE A CYLINDER
HOLLOW BLOCK

40
40
RIM NIGHT LATCH ALSO.
F.F.ROOF SLAB
2. FOR ALL OTHER DOORS, PROVIDE MORTISE
(REFER SCH.)
150

150
F.F.ROOF BEAM LOCK WITH CYLINDER SASH, INCLUDING
10
(REFER SCH.) LEVER HANDLE SET AND 3 Nos. OF KEYS.
3. ALL THE DOORS SHALL BE FIXED WITH
MINIMUM 3 Nos OF BUTT HINGES(100mm).
4. PROVIDE 200mm TOWER BOLTS AT TOP AND
BOTTOM FOR ALL THE DOORS.
340

340
STAIR CASE DETAILS HOLLOW BLOCK
WIDTH = 120CM
TREAD = 30CM G.F.ROOF SLAB 5. PROVIDE A DOOR STOPPER FOR EACH DOOR
RISER = 15.20CM
(REFER SCH.)
SHUTTER (EITHER AT FLOOR LEVEL OR AT
G.F.ROOF BEAM
SIDE WALL, ACCORDING TO THE POSITION OF
950

950
(REFER SCH.)
THE DOOR.)
800

800
6. PROVIDE DUST EXCLUDER FOR ALL EXTERNAL
DOORS AT BOTTOM.
HOLLOW BLOCK
7. ALL THE BATHROOM DOORS SHALL BE
380

380
PROVIDED WITH MORTISE LOCK WITH
THUMB TURN HANDLE AND INDICATOR
8. UNLESS OTHERWISE SPECIFIED THE
PLINTH BEAM
IRONMONGERY SHALL BE IN STAINLESS
(REFER SCH.)
STEEL.
SOLID BLOCK
9. ALL THE IRONMONGERY SHALL BE APPROVED
80

80
F.G.L F.G.L BY THE ENGINEER.
DIST.VARIES

DIST.VARIES
40

40

40
30 30 30 10. ANTI-TERMITE TREATMENT SHALL BE
N.G.L REFER DETAIL C-C N.G.L APPLIED FOR TIMBER WORKS AS PER
MANUFACTURER'S INSTRUCTIONS.

NOTES:-
REFER DETAIL D -D
· ALL THE CEILING SURFACES SHALL BE
SECTION X - X CLEANED BY REMOVING SHEET JOINT LINES ,
SCALE 1:100 ( ALL DIM ARE IN CM'S) TAPES , NAIL STRIP HOLES , CEMENT GROUT
PLUMS ETC., TO GET SMOOTH SURFACE FOR
PRIMER AND PUTTY WORK.

60
10

C COPYRIGHT : -
This drawing is protected by copyright. All rights are reserved.
No part of this drawing may in any form or by any means be reproduced,
10

published, broadcast or transmitted without the prior written permission


of the Muruj Engineering consultancy office.
60

SOLID BLOCK WORK NO: DATE REVISION BY: APP:


5
150

20
15

S
V I CE
GL
30

SER

&
NY
NG I NNN ER I NG CON S UL TA
10

40
10 MURUJ
Engineering Consultancy & Services

UJ E
MU R
Al Kamil
WhatsApp:- 90 90 45 60

60
SOLID BLOCK WORK Email : - murujalkamil@gmail.com
CLIENT NAME :
P C C (1:3:6) Mr . TAAEER BADAR TAAEER AL RASBI
PARAPET DETAIL 10 10 10
40 PLOT NO : - LOCATION : - J . B .BUALI,
6 - 15 - 087 - 05 - 030 AL OLA P/A NORTH
TITLE : -
By Eng:REEM HILAL ALRASBI at 10:14 am, Oct 08, 2023 SECTION X - X
SECTION ON Z - Z
DESIGNED : - JOB NO : -
Hari 0083 / MECS
CHECKED : - SCALE : -
Ram 1 : 100 (A3)

CAD DESIGNER : - DATE : -


Saleesh Khan 01 / 10 / 2023

USE & NO OF FLOORS : - NO OF SHEET : -


Residential & G +1 14 / 21