0% found this document useful (0 votes)
54 views290 pages

L-500 Catalog: LP-Gas & Anhydrous Ammonia Equipment

Uploaded by

David Allauca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views290 pages

L-500 Catalog: LP-Gas & Anhydrous Ammonia Equipment

Uploaded by

David Allauca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 290

L-500 Catalog

LP-Gas & Anhydrous Ammonia Equipment

Application Illustrations 1

Regulators & Accessories A

Cylinder & Service Valves B

Multivalve® Assemblies C

Pressure Relief Valves & Relief Valve Manifolds D

Globe & Angle Valves E

Excess Flow, Check, Filler & Pressure Vapor Equalizing Valves F

Internal Valves & Accessories G

Adapters, Connectors & Fittings H

Miscellaneous Equipment (Including Rotogage® Dials & ESVs) J

Repair Kits R
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer.

Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.
Determining the Age of Products
All RegO products are mechanical devices that will eventually The life of a product is determined by the environment in which it “lives.”
become inoperative due to wear, contaminants, corrosion and aging The LP-Gas dealer knows better than anyone what this environment is.
of components made of material such as metal and rubber.
Since 1960, most RegO products are identified with an alphabetical code
The environment and conditions of use will determine the safe indicating the month and the year they were manufactured.
service life of these products. Periodic inspection and maintenance
are essential. Check the product for this code to determine age. If valves or regulators
are repainted, take care to keep the date code clear for later identification
Because RegO products have a long and proven record of quality and and inspection.
service, LP-Gas dealers may forget the hazards that can occur because
products are used beyond their safe service life.

1960 to 1985 — Two-Letter Date Code Second letter in date code is the year
R — 1960 A — 1969 J — 1978
First letter in date code is the month S — 1961 B — 1970 K — 1979
A — January G — July T — 1962 C — 1971 L — 1980
B — February H — August U — 1963 D — 1972 M— 1981
C — March I — September V — 1964 E — 1973 N — 1982
D — April J — October W— 1965 F — 1974 O — 1983
E — May K — November X — 1966 G — 1975 P — 1984
F — June L — December Y — 1967 H — 1976 Q — 1985
Relief valves used on ASME tanks carry a numerical code indicating Z — 1968 I — 1977
month and year such as 1-75 means January, 1975. EXAMPLE: DL = April of 1980

From 1985 to 1990 — Digit Date Code Second 2 digits in date code are the year
86 — 1986 89 — 1989
First digit in date code is the month 87 — 1987 90 — 1990
1 — January 7 — July 88 — 1988
2 — February 8 — August EXAMPLE: 5-87 = May of 1987
3 — March 9 — September
4 — April 10 — October
5 — May 11 — November
6 — June 12 — December

After 1990 — Digit-Letter-Digit Date Code Letter in date code is the week Second 2 digits in date code are the year
A — 1st week 91 — 1991 97 — 1997
First digit in date code is the month B — 2nd week 92 — 1992 98 — 1998
1 — January 7 — July C — 3rd week 93 — 1993 99 — 1999
2 — February 8 — August D — 4th week 94 — 1994 00 — 2000
3 — March 9 — September E — 5th week 95 — 1995 01 — 2001
4 — April 10 — October 96 — 1996 02 — 2002
5 — May 11 — November 03 — 2003 etcetera. . .
6 — June 12 — December EXAMPLE: 6A21 = First week of June, 2021
*Products with the new “See the Difference” laser
engraving display the full four digit year
Regulator Color Coding EXAMPLE: 6A2021

RegO Domestic first stage, second stage, single stage, and integral twin to accidents and costly service callbacks. The color coding system is
stage LP-Gas regulators are easy to identify. In addition to the standard standard on all 404, LV404, 2302, LV2302, 2403, 2503, LV4403, and
part number marking which indicates the proper application, each regulator LV5503 series domestic LP-Gas regulators manufactured after May of
is color coded to help minimize misapplication in the field that can lead 1986.

Classic Gold Indicates a single stage regulator that is designed to be used alone in single stage systems.
Brilliant Red Denotes a first stage high pressure regulator, normally used in two-stage applications
.in conjunction with a select brown second stage regulator.
Select Brown Signifies second stage low pressure regulators, designed for use in two-stage systems in
conjunction with a brilliant red high pressure regulator — also signifies integral twin stage regulators
.designed to provide benefits of two-stage regulation in one compact unit.
Select Blue Indicates a second stage 2 PSIG delivery pressure regulator and a line pressure regulator downstream
.to reduce 2 PSIG to appliance pressure
Green .High pressure pounds to pounds anhydrous ammonia regulator.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO I
The Tradition Continues

History
From the company that pioneered propane regulators, you expect
nothing less than products that lead the industry. For over 110 years,
we have been manufacturing gas regulating equipment to the highest
standards of precision and durability—standards that we set.

Over 110 Years


and we're Long Lasting Product
just getting With the largest installed base in the industry, RegO has over 110
started.
years of field proven track record of long lasting service.

Industries Best Partners to Help Support You


Our distributors are the best in the industry. Distributors are
MASTER DISTRIBUTOR
S NETWORK indispensable contributors to our success and we treat them as the
valuable partners they are. We support our distributors and OEMs
with training, inventory and technical support around the world.

Manufacturing Excellence
RegO uses top quality materials and precise robot-assisted
manufacturing in our US factories. That means every product has
consistent quality.

Quality Design & Manufacturing


Our regulators have stood the test of time. The basic design
is ingenious. The materials are top quality. The robot-assisted
manufacturing is precise. RegO values the relationships we have
with our customers, and we stand behind our products.

II Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
A Better Built Valve Means Low Cost of Ownership
REGO 100% Testing
100% All our products are 100% tested at multiple steps in the process
TESTED from incoming component quality to final assembly testing for
leakage, lock up and set pressure.

10
10 Year Warranty on All Products
REGO
RegO values the relationships we have with our customers, and
we stand behind our products. We support our channel partners
with ongoing training and technical assistance. Quality materials,
YEAR
innovations and long lasting design are built into every product
WARRANTY
we manufacture. That’s how we can offer the RegO 10 Year
Warranty, double that offered by most manufacturers.

25
REGO
25 Year Silver Service Life
RegO Regulators stand the test of time. With an Industry leading
YEAR
25 year recommended service life our regulators provide a lower
cost of ownership and reliable service.
SILVER SERVICE LIFE

PPAP
Supply Chain Management
RegO utilizes the Production Part Approval Process (PPAP) in our
supply chain. Critical measurements are taken of all components
parts to ensure quality and reliability.

World-class quality—but don’t just take our word for it.


RegO builds products that last. Our durable materials, proven designs, and rigorous testing,
all add up to products designed for years of operations under harsh conditions. With internal
standards like these, it’s no wonder that RegO quality is recognized the world over.

LISTED ISO 9001:2015 TPED ASME & NB

CRN

REGISTERED

PED CRN ATEX

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO III
RegO Innovations -
The Tradition Continues
From the company that pioneered propane regulators, you expect indispensable contributors to our success and we treat them as the
nothing less than products that lead the industry. For over 110 years, valuable partners they are. We support our distributors with training,
we have been manufacturing gas regulating equipment to the highest inventory and technical support.
standards of precision and durability—standards that we set.
10 Year Warranty on All Products
Our regulators have stood the test of time. The RegO 10 Year Warranty is double what most manufacturers offer.
The basic design is ingenious. The materials are top quality.
The robot-assisted manufacturing is precise. RegO values the All of our regulators are designed, assembled and tested in North
relationships we have with our customers, and we stand behind our Carolina. Products Made in the USA allow us to maintain our strict
products. quality control standards that are unmatched by any other company.
Every single unit is rigorously tested before it goes out the door.
Our distributors are the best in the industry. Distributors are

See The Difference


Easy to Service Easy to Identify
Seat Discs can be easily accessed by service Our bonnet design features patented laser engraved
techs for repair or replacement. information (part number, date code of manufacture,
outlet pressure and serial number) that is easy to see
and matches stickers provided for gas check and
record keeping.

Standard Tools
Bonnet cap requires only hand
tightening to ensure a tight seal - no
wrench required.

Gas Check Labels Easy to Install


2 Gas Check stickers with product
Service tech friendly wrench flats
information are included for ease of
for use with an adjustable wrench.
record keeping.
Mounting screws included.

Double the Warranty


The RegO 10 Year Warranty is double
what most manufacturers offer.
Superior Design
Superior vent design has a flathead
screwdriver slot for easy removal &
minimizes water entering the regulator
bonnet.
Easy to Buy
Supported by the largest network of distributors worldwide.

IV Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
1
Section 1
Application Illustrations
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Bulk Transport Solutions


Breadth of line meets depth of knowledge
Combine our industry experience, product design experience and
broad product line to build a flow control system that enables maximum
efficiency and excellent value for bulk transport applications.

I N T E R N A L V A LV E A N D
P U M P A S S E M B LY

ANGLE VALVE
A7704 SERIES

INTERNAL VALVE
WITH ROTARY
ACTUATOR
A3219 SERIES ACME ADAPTER
A3219FA SERIES 5769 SERIES

ROTOGAGE® DIAL
A9090 SERIES

VI Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
ACME ADAPTER
5767 SERIES
GLOBE VALVE 5769 SERIES
A7500 SERIES

GLOBE VALVE INTERNAL VALVE


A7500 SERIES WITH ROTARY
ACTUATOR
A3200 SERIES

GLOBE VALVE
A7500 SERIES

ACME CAP
3184 SERIES
3194 SERIES PRESSURE RELEASE
VALVE
A8436 SERIES

ACME CAP
3184 SERIES
3194 SERIES

INTERNAL VALVE
WITH ROTARY
ACTUATOR
A3200 SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
VII
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Bulk Storage Solutions


A complete portfolio for your entire system.
Backed by our industry-leading, 10-year warranty and expert technical
support, reliable RegO products are designed and built to deliver years of DELTAPORT
worry-free performance. 8530 SERIES

MULTIPORT
TM

A8560 SERIES
A8570 SERIES

BACK CHECK VALVE


A3186 SERIES
FEMALE ACME
CONNECTOR
3181 SERIES
PULL AWAY ANGLE VALVE
COUPLING A7500 SERIES
A2141A SERIES

GLOBE VALVE
A7500 SERIES

EMERGENCY
ACME SHUT-OFF VALVE
LOW EMISSION LIQUID OR VAPOR
HOSE END VALVE
A6010 SERIES
A7914A A6016 SERIES
A6024 SERIES
VIII Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
GLOBE VALVE
A7500 SERIES

PRESSURE
SIGHT FLOW RELIEF VALVE
INDICATOR
7534 SERIES
A7790 SERIES

ROTOGAGE® DIAL
SWING CHECK A9090 SERIES
VALVE WITH FLOW
INDICATOR
A7600 SERIES

BACK CHECK VALVE


A3186 SERIES
HYDROSTATIC
RELIEF VALVE
3127 SERIES
SS8000 SERIES

INTERNAL VALVE
GLOBE VALVE
A3200 SERIES
A7500 SERIES

HYDROSTATIC
RELIEF VALVE
3127 SERIES
SS8000 SERIES

GLOBE VALVE
A7500 SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
IX
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Bobtail Delivery Solutions


Delivering peace of mind—and profitability.
Dependability, safety and speed are key drivers for transporting
LP-Gas. All RegO products are 100% tested to withstand the rigors of
ROTOGAGE® DIAL
day-to-day operations. They're easy-to-use, and open and shut securely
A9090 SERIES
for faster flow rates and maximum safety.

PRESSURE
RELIEF VALVE
A8434G SERIES

INTERNAL VALVE
WITH ROTARY OR
ELECTRIC ACTUATOR
A3200D SERIES

ANGLE VALVE CHECK VALVE HYDROSTATIC ACME CAP


A7500 SERIES A3186 SERIES RELIEF VALVE
3184 SERIES
SS8000 SERIES 3194 SERIES

X Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
B O B TA I L P U M P
A S S E M B LY

GLOBE VALVE
A7500 SERIES

HOSE END VALVE


A7797A/L SERIES

INTERNAL VALVE
A3217 SERIES
OR FLOMATIC®
A7883 SERIES

AVAILABLE ROTARY
ACTUATOR
A3200RA/OA SERIES

HOSE END ADAPTERS


7577 SERIES
3179 SERIES
7576 SERIES

ACME ADAPTER
5767 SERIES
5769 SERIES

PULL AWAY
COUPLING
A2141A SERIES

HYDROSTATIC
RELIEF VALVE
3127 SERIES EMERGENCY
SS8000 SERIES SHUT-OFF VALVE
LIQUID OR VAPOR
ANGLE VALVE
A6010 SERIES
A7500 SERIES
A6016 SERIES
A6024 SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
XI
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Domestic Solutions


A B O V E G R O U N D TA N K
Built-in quality, for superior reliability.
High-grade metals, expert engineering, a skilled U.S.
workforce, advanced manufacturing techniques and 100%
testing is the formula for RegO quality. Quality that delivers
years of dependable performance, lower costs, fewer service
calls and more satisfied end users.

FIRST STAGE
REGULATOR PRESSURE
CHECK-LOK® VALVE
LV4403 SERIES RELIEF VALVE
7590 SERIES LV3403 SERIES 7583 SERIES
8684 SERIES
8685 SERIES

PIGTAIL
913 SERIES
912 SERIES
FILLER VALVE PRESTO-TAP® PIGTAILS MULTIVALVE®
ASSEMBLIES
L6579 SERIES PT913 SERIES
L7579 SERIES PT912 SERIES PT7556 SERIES
SFL7579 SERIES 7556 SERIES

XII Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
D OT CO N TA I N E R TA N K

TWIN STAGE
REGULATOR
LV404B SERIES
LV404Y SERIES

U N D E R G R O U N D TA N K

S E C O N D S TA G E
R E G U L AT O R

SECOND STAGE
REGULATOR
LV3403 SERIES
LV4403 SERIES
LV5503 SERIES

FIRST STAGE
REGULATOR UNDERGROUND
LV4403 SERIES MULTIVALVE®
LV3403 SERIES ASSEMBLY
PG8475 SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
XIII
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Cylinder Solutions


DOT & ASME: A complete
portfolio of performance.
Whether it's the hard working service valve
or the patented RegO Multivalve® assembly,
you can count on years of fast, secure liquid
and vapor transfer for your cylinders—and
your customers.

CYLINDER VALVE MULTIVALVE® CYLINDER VALVE CYLINDER VALVE


LIQUID & VAPOR ASSEMBLY LIQUID VAPOR
WITHDRAWAL LIQUID WITHDRAWAL WITHDRAWAL
WITHDRAWAL
8556 SERIES 9107K8A SERIES 9103 SERIES
8555DL SERIES

SERVICE VALVE DOUBLE CHECK MULTIVALVE® PRESSURE


DOT & ASME FILLER VALVE ASSEMBLIES RELIEF VALVE
VAPOR
*9101 SERIES DOT & ASME WITHDRAWAL DOT
*9102 SERIES **7647 SERIES 8544K SERIES
**L7579 SERIES DOT
6533 SERIES ASME
6543 SERIES 8544G SERIES
ASME MULTIVALVE®
6532R/6542R ASSEMBLY
MULTIVALVE® VAPOR
ASSEMBLY WITHDRAWAL
VAPOR *8555 SERIES
WITHDRAWAL (UP TO 200 LB. DOT)
*6555 SERIES
(UP TO 60 GALLON
W.C. ASME
CONTAINERS)

DOT 420 LBS. ASME 120 GAL W.C. ASME 60 GAL W.C. DOT 100 LBS. DOT 200 LBS.

*LOW EMISSION VERSION AVAILABLE ** STANDARD LOW EMISSION PRODUCTS

XIV Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO Auto Gas Solutions
Mile after mile, or up and down the aisle
Engineered for years of economical operation and quick fill-ups,
LIQUID SERVICE
RegO's heavy-duty valves and tight seals keep you rolling. VALVE
9101 SERIES

FIXED LIQUID
LEVEL GAUGE
*3165 SERIES
FILLER VALVE
WITH CAP
*7647 SERIES
PRESSURE FIXED LIQUID
RELIEF VALVE LEVEL GAUGE
8544 SERIES 3165 SERIES
SERVICE VALVE PRESSURE
RELIEF VALVE
9101P SERIES 8545AK SERIES
WITH DEFLECTOR
7545 SERIES
AND RAIN CAP
9103 SERIES
FEMALE SAFETY MALE SAFETY
FILLER VALVE CONNECTOR CONNECTOR
WITH CAP 7141F SERIES 7141M SERIES
*7647 SERIES
*7647SC SERIES *LOW EMISSIONS
MULTIVALVE® MULTIVALVE®
ASSEMBLY ASSEMBLY
7556R SERIES 8118P SERIES

PRESSURE HYDROSTATIC
RELIEF VALVE RELIEF VALVE
8685G SERIES 3127 SERIES

PULL AWAY EXCESS FLOW CHECK-LOK® VALVE


COUPLING VALVE
7590 SERIES
A2141A SERIES 3272H
EMERGENCY
SHUT-OFF VALVE ELECTRIC ACTUATOR
A6006 FUELING NOZZLE A3209E
A6008
FN SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
XV
R E G O L P - G A S P R O D U C T A P P L I C AT I O N S

RegO Outdoor & Recreational Solutions


RegO works weekends—and every other day
Our superior products are designed to fill faster, last longer and work
reliably for years. Whether your application gets daily or occasional use,
one thing is for sure—RegO stands behind our products every day.

FIXED LIQUID
LEVEL GAUGE
3165 SERIES

SERVICE VALVE
9101P SERIES

FILLER VALVE
WITH CAP
*7647 SERIES

REGULATOR
302 SERIES

ACME CHECK
CONNECTOR PRESSURE
RELIEF VALVE
7142LF SERIES
7142LM SERIES 8545 SERIES
8544 SERIES

AUTOMATIC
CHANGEOVER
TWIN STAGE
REGULATOR
*LOW EMISSIONS
7525B SERIES

XVI Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO Anhydrous Ammonia Solutions
You can bet the farm on our performance
Demanding applications require products you can trust. RegO offers more
NH3 options, and they are all backed with our industry-leading
10-year warranty to help your customers improve their yields with safe,
even applications year after year.

MULTIPURPOSE
PRESSURE
LIQUID VALVE
RELIEF VALVE
WITHDRAWAL A8016D SERIES
VALVE AA3130UA SERIES
AA3135UA SERIES
A8017 SERIES
A8012 SERIES

PRESSURE FIXED LIQUID


GAUGE LEVEL GAUGE
A8400 SERIES TSS3169 SERIES

The illustrations in this application guide are intended to inform a professional installer/system designer where our valves are generally
installed on certain containers or applications. These illustrations are not intended for and must not be used for system design.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
XVII
Section A
Regulators and Accessories A A

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
A warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

A2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F (-40°C to +73°C), unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. A
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A3
RegO Regulator Dependability

When RegO LP-Gas Regulators are properly installed, safe, precise, All give you a product that provides accurate gas delivery under
trouble-free service is the result. varying pressure ranges and load conditions.
Dependability is built into every regulator ... the result of rigid RegO LP-Gas Regulators are UL listed and comply with applicable
standards of quality control and close tolerance machining. And this code requirements.
has been true for more than 90 years. RegO Products offer a complete line of LP-Gas Regulators with
RegO Products are manufactured from the finest materials, and capacities for almost every application.
assembled and tested using procedures second to none.

RegO Regulator Selection


In order to properly size the RegO Regulator, find the total load of 5. Find the line on the chart corresponding to the lowest anticipated
the installation. The total load is calculated by adding up the input winter tank pressure (note that each performance line corresponds
ratings (BTU or CFH) of all appliances in the installation. Input ratings to and is marked with a different inlet pressure in PSIG).
may be obtained from the nameplates on the appliances or from the 6. Draw a vertical line upward from the point of assumed load
manufacturers’ literature. (500,000 BTU’s per hour) to intersect with the line corresponding
Determine the type of regulation needed referring to the chart below. to the lowest tank pressure.
7. Read horizontally from the intersection of these lines to the
Type of System Maximum Load Suggested Regulator
delivery pressure at the left side of the chart. In this example the
1,500,000 LV3403TR delivery pressure will be 9.2 PSIG. Since the delivery pressure
First Stage in a Two will be 9.2 PSIG at the maximum load conditions and lowest
Stage System LV4403SR Series
2,500,000 anticipated tank pressure, the regulator will be sized properly for
LV4403TR Series
the demand.
LV3403B Series Example for a Second Stage Regulator
450,000
LV3403BR Series LV4403TR Series First Stage Regulator
Second Stage in a LV4403B Series
935,000 150 PSIG Inlet
Two Stage System LV4403BD Series
Delivery Pr essur e
12 Initial Setting 125 PSIG Inlet
1,600,000 LV5503B4/B6 11 100 PSIG Inlet
10
2,300,000 LV5503B8
PSIG

9
Second Stage in a 2 1,000,000 LV4403Y4/Y46R 8
PSIG System 2,200,000 LV5503Y6/Y8 7
15 PSIG Inle t 50 PSIG Inle t
A Integral Twin Stage
450,000 LV404B34/39 Series 25 PSIG Inle t
525,000 LV404B4/B9 Series CFH/hr. 100 200 300 400 500 600 700 800 900 100 0
BTU/h r. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
Integral Twin Stage 800,000 LV404Y9
2 PSIG Delivery 650,000 LV404Y39
Automatic 400,000 7525B34 Series 1. Assume load of 250,000 BTU’s per hour.
Changeover 450,000 7525B4 Series 2. Assume a minimum delivery pressure of 10” w.c.
* See catalog page for inlet and delivery specifications. 3. Assume a minimum inlet pressure of 10 PSIG.
Now determine which regulator in the Series would be most suitable. 4. For these conditions, refer to chart for the LV4403B Series,
Turn to the individual product pages and refer to the Performance Second Stage Regulator, shown below.
Curves. Check the performance of the regulator with your actual load 5. Find the line on the chart corresponding to the anticipated inlet
conditions at the minimum LP-Gas inlet pressure for the regulator. pressure.
Use the pressure corresponding to your lowest winter temperatures 6. Draw a vertical line upward from the point of assumed load
shown in the chart below or refer to the delivery pressure of your first (250,000 BTU’s per hour) to intersect with the line corresponding
stage regulator. to the lowest inlet pressure.
Approx. Approx. Pressure 7. Read horizontally from the intersection of these lines to the
Temperature Temperature delivery pressure at the left side of the chart. In this example the
Pressure (PSIG) (PSIG)
delivery pressure will read 10.1” w.c. Since the delivery pressure
°F °C Propane Butane °F °C Propane Butane will be 10.1” w.c. at the maximum load condition and lowest
-40 -40 3.6 40 4 72 3.0 anticipated inlet pressure, the regulator is sized properly for the
demand.
-30 -34 8 50 10 86 6.9
-20 -29 13.5 60 16 102 12
-10 -23 23.3 70 21 127 17
LV4403B Series Second Stage Regulator
0 -18 28 80 27 140 23
Inches of W ater Colum n

10 -12 37 90 32 165 29
Initial Setting
Delivery Pr essur e

20 -7 47 100 38 196 36 13
30 -1 58 110 43 220 45 12
15 PSIG Inlet
11
Example for a First Stage Regulator 10
9
1. Assume a load of 500,000 BTU’s per hour. 5 PSIG Inlet 8 PSIG Inlet 10 PSIG Inlet
2. Assume a minimum delivery pressure of 9.5 PSIG.
CFH/hr. 0 50 100 150 200 250 300 350 400 450 500
3. Assume a minimum tank pressure of 15 PSIG. BTU/hr. 250,000 500,000 750,000 1,000,000 1,250,000
4. For these conditions, refer to chart for the LV4403TR Series, First
Stage Regulator, shown below.

A4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Safety Warnings

Purpose
In its continuing quest for safety, RegO publishes a series of bulletins explaining the hazards associated with
the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these factual bulletins will make
clear to LP-Gas dealer managers and service personnel, that the utmost care and attention must be used in
the installation, inspection, and maintenance of these products, or problems could occur which would result in
injuries and property damage.

The National Fire Protection Association NFPA 58 Liquefied Petroleum Gas Code - 2020 Edition states in
Section 4.4 Qualification of Personnel; ”Persons whose duties fall within the scope of this code shall be
provided with training that is consistent with the scope of their job activities and that includes proper handling
and emergency response procedures... Refresher training shall be provided at least every 3 years, initial and
subsequent training shall be documented”. These “RegO Safety Warnings” may be useful in training new
employees and reminding older employees of hazards that can occur. It is recommended that all employees
complete the Propane Education Research Council’s Certified Employee Training Program.
Nature of Warnings
It is recognized that warnings should be as brief as possible, but The Causes of High Pressure Gas in a System are:
the factors involved in regulator failures are not simple. They need
to be fully understood so that proper maintenance programs can be 1. Regulator vents that are clogged or obstructed.
established. If there is a simple warning, it would be: Vents must be clear and fully open at all times.

Inspect regulators regularly as outlined in this safety warning and Many regulators are equipped with a pressure relief valve which
replace as required per these recommendations. When all of discharges to atmosphere through the vent. Ice, snow drifts, dirt,
these recommendations are followed, the recommended service bugs, paint, or other foreign material can clog the vents.
life of an RegO regulator (except single stage) manufactured after An obstructed vent may prevent the pressure relief valve from
1995 is 25 years. The recommended service life of all other RegO operating properly.
regulators is 15 years.

LP-Gas Regulators

This bulletin applies most particularly to permanent LP-Gas


installations of cylinders and tanks. The warnings also apply
in most cases to portable installations of recreational vehicles,
A
barbecue grills, etc.
This bulletin is not intended to be an exhaustive treatment of
Large Vent
the subject of regulators and certainly does not cover all
safety practices that should be followed in the installation and
maintenance of LP-Gas systems.

It should not be necessary to remind readers of this bulletin that


regulators must be installed in strict conformance with NFPA
Pamphlets 54 and 58, and all other applicable codes and regulations.
Codes, regulations and manufacturer’s recommendations have been
developed by experts with many years of experience in the LP-Gas
Regulators should be installed with the vent facing down or protected
industry.
so their operation will not be affected by the elements. In cases
Failure to fully follow these codes, regulations and where the regulator vent is equipped with a discharge tube, the outlet
recommendations could result in hazardous installations. of this tube must be facing down. The vents and/or discharge tubes
Pamphlet 58 states “All regulators for outdoor installations, except must be protected from the elements and must be equipped with a
regulators used for portable industrial applications, shall be designed, screen to prevent bugs from obstructing the opening.
installed or protected so their operation will not be affected by
Action Required: Regulators should be properly installed and
the elements (freezing rain, sleet, snow, ice, mud or debris). This
regularly inspected when tanks or cylinders are filled. If vents are
protection may be integral with the regulator.”
clogged or the screen is missing, they must be cleaned or replaced.
If the vent screen is missing and there is evidence of foreign material
Failed and/or Inoperative Regulators
around the vent, the regulator should be replaced.
Failed regulators can cause three kinds of hazards:
2. Foreign material lodging between the regulator nozzle and
• High pressure LP-Gas in a system downstream of the regulator; and
• Leaks of LP-Gas to atmosphere from the regulator itself. seat disc:
• Loss of pressure due to a “freeze-up” in the orifice. When this occurs, the regulator can remain open, allowing high
pressure gas into the system.
High Pressure LP-Gas in a System
Anything that prevents a regulator from regulating properly could
result in high pressure gas at the regulator outlet and thus in a
system.
High pressure gas into piping and appliances could cause piping
leaks and damage to appliance burner controls with the potential
for fires and explosions.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A5
Safety Warnings

This material can come from system piping between the container shut-
off valve and the regulator. Chips created during piping installation or
dirty piping can create this hazard. Corrosion inside of copper pigtails
and piping can cause problems. This can occur particularly when
LP-Gas contains high sulphur or excessive moisture.
Action Required: Make sure regulator inlet piping is clean at the
time of installation. Periodic checks should be made to ensure piping
remains clean without corrosion. Never use old pigtails on new LP-Gas
installations. Old pigtails can also work harden and crack if they have
been bent and twisted several times.
3. Wrong regulator installed for the application:
The proper regulator must be used for each system.
For example, installation of high pressure regulators not designed to Action Required: Be careful of regulator installation and never overfill
reduce gas pressure to an appliance requirement of 11” w.c. will cause any LP-Gas container.
a hazard. Installing a regulator undersized for the load can cause
improper combustion at the appliance burner with a potential for carbon Leaks of LP-Gas to Atmosphere
monoxide poisoning. While the occurrences of leaking regulators are rare, they can
Action Required: Make sure the regulator is correct for each and do occur with a potential for fires and explosions.
application and test the system with a pressure gauge or a manometer. These leaks can be caused by:
4. Failure to external mechanical parts due to corrosion: 1. Corrosion of the relief valve spring or foreign material on the seat
Adjusting springs and relief valve springs can rapidly corrode if exposed disc which causes the relief valve to open, will cause LP-Gas to
to salt air or industrial pollution. Even moisture condensation on these escape through the regulator vent, as well as permitting high pressure
springs can cause them to rust and fail. into the system.
Failure of these springs will result in failure of the regulator to
control the pressure. Action Required: Regulator inspection for corrosion should be made
With the vent of a regulator facing down, corrosion products from the according to the guidelines listed below:
springs could clog the regulator vent screen blocking the vent. • For underground installations subject to submersion, the regulator
should be inspected every time the container is filled.
Action Required: Regulator inspection for corrosion should be made
• For known corrosive atmospheres of salt air or chemical pollution,
A according to the guidelines listed below:
the regulator should be inspected at least once a year.
• For underground installations subject to submersion, the regulator
should be inspected every time the container is filled. • For other applications, the regulator should be inspected every 3
years.
• For known corrosive atmospheres of salt air or chemical pollution,
the regulator should be inspected at least once a year. If any corrosion is evident, replace the regulator.
2. Bad piping connections at the regulator inlet and outlet. This can
occur at the time of installation where connections are loose or the
regulator may have been overstressed by excessive wrenching. It
is important that proper wrenches, both on the piping and on the
regulator inlet and outlet, be used when connecting the system piping,
and that the regulator die cast body is not cracked by wrenching the
pipe too deeply into the body.
Action Required: Always test for leaks at time of installation and
inspect for leaks if there is reason to believe that pipe connections
could cause a hazard.

Corroded
Spring

• For other applications, the regulator should be inspected every 3


years.If any corrosion is evident, replace the regulator.
It is essential that the regulator bonnet cap be tightly in place at
all times to prevent the entrance of water, bugs, dirt, etc. Foreign
material can cause the regulator to function improperly with potentially
hazardous results.
5. Liquid propane in the regulator:
This can occur on recreational vehicles, unless the regulator is
installed substantially higher than the container shut-off valve. Here,
sloshing propane could get into the regulator with the resulting high
pressure downstream of the regulator. It could also occur on stationary
installations if the regulator is installed below the shut-off valve and the
container is over-filled.

A6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Safety Warnings

Loss of Pressure Underground Installations


Freeze-up inside the regulator. Special hazards can occur if regulators are not properly installed in
underground systems. Water, dirt, mud and insects can get into the
regulator if the bonnet cap is not tightly in place and the vent is not
protected with a proper vent tube, opening above any potential water
level.
Most problems occur because the waterproof dome on the buried
storage tank does not extend above the ground level sufficiently to
keep out water and mud.
Ice Refer to NPGA No. 401.

This will prevent the regulator from regulating properly.


Regulator freeze-ups occur because there is excessive moisture
in the gas. Freeze-ups can also occur in pigtails that are kinked or
bent where free flow of the LP-Gas is restricted. These freeze-ups 18
can occur when the moisture, gas flow and temperature combine to
create a hazardous condition. Freeze-ups can occur at temperatures
above 32º F.
Action Required: All LP-Gas should be checked for moisture content
prior to delivery to consumers and proper amounts of anhydrous
methanol added if the gas cannot be returned to the supplier. Any Note: Water mark left in housing dome at level
container suspected of having excessive moisture should be treated above regulator vent, or end of vent tube requires
with the proper amount of methanol. replacement of regulator. Then correct installation.
A

Customer Safety General Warning


Since regulators are often used by consumers without previous
knowledge of the hazards of LP-Gas, and the LP-Gas dealers are the All RegO Products are mechanical devices that will eventually
only ones who have direct contact with the consumers, become inoperative due to wear, contaminants, corrosion
and aging of components made of materials such as metal
It is the dealer’s responsibility to make sure that his and rubber. As a general recommendation,Regulators should
customers are properly instructed in safety matters relating be replaced in accordance with all of the recommendations
to their installation. outlined in this safety warning. The recommended service
life of a regulator is one of many factors that must be
At the very minimum, it is desirable that these customers: considered in determining when to replace a regulator.
1. Know the odor of LP-Gas and what to do in case they smell
gas. Use the NPGA “Scratch ’n Sniff” leaflet. The environment and conditions of use will determine the safe
2. Are instructed to never tamper with the system. service life of these products. Periodic inspection and maintenance
3. Know that when protective hoods are used to enclose are essential.
regulators and/or valves, that these hoods must be closed, Because RegO Products have a long and proven record of quality
but not locked. and service, LP-Gas dealers may forget the hazards that can occur
4. Keep snow drifts from covering regulators. because a regulator is used beyond its safe service life. Life of a
5. Know the location of the cylinder or tank shut-off valve in regulator is determined by the environment in which it “lives.” The
emergencies. LP-Gas dealer knows better than anyone what this environment is.
NOTE: There is a developing trend in state legislation and
in proposed national legislation to make the owners of products
responsible for replacing products before they reach the end of their
safe useful life. LP-Gas dealers should be aware of legislation which
could affect them.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A7
Advantages of Two-Stage Regulation

First Stage Regulator


with Relief Valve and
Second Stage
Pressure Tap
Regulator
with Large Vent and
Pressure Tap
To Appliances/Furnace

First Stage Piping

Two-stage systems can greatly reduce the possibility of freeze-ups


The regulator is truly the heart of an LP-Gas installation. It must and resulting service calls as the expansion of gas from tank pressure
compensate for variations in tank pressure from as low as 8 PSIG to 11” w.c. is divided into two steps, with less chilling effect at each
to 220 PSIG – and still deliver a steady flow of LP-Gas at 11” w.c. regulator. In addition, after the gas exits the first-stage regulator and
to consuming appliances. The regulator must deliver this pressure enters the first-stage transmission line, it picks up heat from the line,
further reducing the possibility of second-stage freeze-up.
despite a variable load from intermittent use of the appliances. Service calls for pilot outages and electronic ignition system failures
Though a single-stage system may perform adequately in many are also reduced as a result of more uniform appliance pressure from
installations, the use of a two-stage system offers the ultimate in pin- two-stage systems.
point regulation. Two-stage regulation can result in a more profitable
A LP-Gas operation for the dealer resulting from less maintenance and Economy of Installation
fewer installation callbacks – and there is no better time than now for In a single-stage system, transmission line piping between the
installing RegO Regulators in two-stage systems. container and the appliances must be large enough to accommodate
the required volume of gas at 11” w.c. In contrast, the line between
Uniform Appliance Pressure the first and second stage regulators in two-stage systems can be
The installation of a two-stage system – one high pressure regulator much smaller as it delivers gas at 10 PSIG to the second-stage
at the container to compensate for varied inlet pressures, and one regulator. Often the savings in piping cost will pay for the second
low pressure regulator at the building to supply a constant delivery regulator.
pressure to the appliances – helps ensure maximum efficiency As an additional benefit, single-stage systems can be easily
and trouble-free operation year-round. It is important to note that converted to two-stage systems using existing supply lines when they
while pressure at the appliances can vary up to 4” w.c. using single- prove inadequate to meet added loads. This is the least expensive
stage systems, two-stage systems keep pressure variations within and best method of correcting the problem.
1” w.c. New high-efficiency appliances require this closer pressure
control for proper ignition and stable, efficient operation. In fact, one Allowance for Future Appliances
major manufacturer requires the use of two-stage systems with their A high degree of flexibility is offered in new installations of two-
appliances. stage systems. Appliances can be added later to the present load –
provided the high pressure regulator can handle the increase – by the
Reduced Freeze-ups/Service Calls
addition of a second low pressure regulator. Since appliances can be
Regulator freeze-up occurs when moisture in the gas condenses and regulated independently, demands from other parts of the installation
freezes on cold surfaces of the regulator nozzle. The nozzle becomes will not affect their individual performances.
chilled when high pressure gas expands across it into the regulator
body. This chilling action is more severe in single-stage systems as
gas expands from tank pressure to 11” w.c. through a single regulator
nozzle.

Size The System Correctly


Prior to installing your two-stage system, be sure the system pipe Replace Pigtails
and tubing is properly sized. Proper sizing will help ensure constant If you are replacing an old regulator, remember to replace the
delivery pressure to the appliances during fluctuating loads at all copper pigtail. The old pigtail may contain corrosion which can
times. Just as important, be sure the RegO Regulators you choose restrict flow. In addition, corrosion may flake off and wedge
are capable of handling the desired load. This is another advantage between the regulator orifice and seat disc – preventing proper
of two-stage systems – they are capable of handling much lock-up.
more BTU’s/hr. than single-stage systems. The RegO “LP-Gas
Serviceman’s Manual” provides complete information on pipe sizing
and proper regulator selection.

A8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Two-Stage LP-Gas Systems

Require First Stage Regulators with Built-in Relief Valves

First Stage Regulator


with Relief Valve and
Pressure Tap Second Stage
Regulator
with Large Vent
and Pressure Tap
To Appliances/Furnace

First Stage Piping

Ambient Ground Pressure at Which


With no first stage relief valve, Temperature Tank Pressure Temperature liquid will form
propane liquid may form here. . .
70° F. 120 PSIG 40° F. 72 PSIG

Resulting in sudden pressure surge due to flashing into vapor here! 80° F. 140 PSIG 50° F. 86 PSIG
First stage relief can prevent liquid from forming in first stage piping 90° F. 165 PSIG 60° F. 102 PSIG
during periods with no gas demand! ! !

Pressure at which liquid can form


at various temperatures.

Vapor Pressures of LP-Gases A


250

200
Pressure PSIG

150
Propane

100

50
Butane

-40 -20 0 20 40 60 80 100 120


Temperature °F.

The Problem
Many modern LP-Gas appliances are equipped with pilotless ignition stage regulator will not relieve the pressure in first stage piping.
systems. Water heaters and older appliances use pilot lights, but it The rapid vaporization of the liquid may cause a rapid pressure surge
has become a common practice for energy conscious homeowners to that could seriously damage critical components of the appliance and
shut-off the pilot when leaving home for extended periods of time. In furnace controls.
each instance, there is no gas demand at all for extended periods.
A fire or explosion could occur as a consequence.
The Consequences
If the first stage regulator fails to lock-up tight, usually as a result The Solution
of a worn seat disc or foreign material lodged between nozzle and RegO LV4403 Series First Stage Regulators with Built-In Relief
seat disc, pressure will build-up in the first stage piping – possibly Valves reduce the possibility of this serious hazard in two stage
to a level that approaches tank pressure. Combining this with warm applications. The built-in relief valve is designed to vent as needed
ambient temperatures and cool ground, propane liquid may form in and reduce the possibility of first stage piping pressure from
the first stage piping. becoming high enough to form liquid.
When gas demand resumes, this liquid may pass through the second
stage regulator into the appliances and furnace. NOTE – the second

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A9
Pipe and Tubing Selection Guide

Use the following simple method to ensure the selection of the correct sizes of piping and tubing for LP-Gas vapor systems. Piping between the first and second stage
is considered, as well as lower pressure (2 PSIG) piping between the 2 PSIG second stage or integral twin stage regulator and the line pressure regulator; and low
pressure (inches of water column) piping between second stage, single stage, or integral twin stage regulators and appliances. The information supplied below is
from NFPA 54 2021 (National Fuel Gas Code) Chapter 6 and Annex B, and NFPA 58 2020 (Liquefied Petroleum Gas Code) Chapter 16; it can also be found in CETP
(Certified Employee Training Program) published by the Propane Education and Research Council “Selecting Piping and Tubing” module 4.1.8. These illustrations are for
demonstrative purposes, they are not intended for actual system design.

Instructions:
1. Determine the total gas demand for the system by adding up the BTU/hr input
from the appliance nameplates and adding demand as appropriate for future
appliances.
2. For second stage or integral twin stage piping:
A. Measure length of piping required from outlet of regulator to the appliance Length to Furthest Appliance
furthest away. No other length is necessary to do the sizing.
B. Make a simple sketch of the piping, as shown.
C. Determine the capacity to be handled by each section of piping. For
example, the capacity of the line between a and b must handle the total
demand of appliances A, B, and C; the capacity of the line from c to d must
handle only appliance B, etc.
D. Using Table 3 select proper size of tubing or pipe for each section of piping,
using values in BTU/hr for the length determined from step #2-A. If exact
length is not on chart, use next longer length. Do not use any other length
for this purpose! Simply select the size that shows at least as much capacity
as needed for each piping section.
3. For piping between first and second stage regulators
A. For a simple system with only one second stage regulator, merely measure
length of piping required between outlet of first stage regulator and inlet of
second stage regulator. Select piping or tubing required from Table 1.
B. For systems with multiple second stage regulators, measure length of piping
required to reach the second stage regulator that is furthest away. Make a
simple sketch, and size each leg of piping using Table 1, 2, or 3 using values
shown in column corresponding to the length as measured above, same as
when handling second stage piping.

Example 1 Example 2.
Determine the sizes of piping or tubing required for the twin-stage LP-Gas Determine the sizes of piping or tubing required for the two-stage LP-Gas
installation shown. installation shown.
Total piping length = 84 feet (use Table 3 @90 feet)
From a to b, demand = 38,000 + 35,000 + 30,000 26 58 Feet
= 103,000 BTU/hr; use ¾” pipe or ¾” tubing Feet 200,000
From b to c, demand = 38,000 + 35,000
= 73,000 BTU/hr; use ½” pipe or ⅝” tubing aa
From c to d, demand = 35,000 BTU/hr; use ½” pipe or ½” tubing
65,000
From c to e, demand = 38,000 BTU/hr; use ½” pipe or ½” tubing
From b to f, demand = 30,000 BTU/hr; use ½” pipe or ½” tubing h
a f
a b c d

g e

84 Feet
30,000 35,000

38,000

Total first stage piping length = 26 feet; first stage regulator setting is
10 PSIG (use Table 1 or 2 @ 30 feet)
From aa to a, demand = 338,000 BTU/hr; use ½” pipe, ½” tubing, or ½” T
plastic pipe.
Total second stage piping length = 58 feet (use Table 3 @ 60 feet)
35,000
From a to b, demand = 338,000 BTU/hr; use 1” pipe
From b to c, demand = 138,000 BTU/hr; use ¾” pipe or ⅝” tubing
38,000 From c to d, demand = 100,000 BTU/hr; use ½” pipe or ⅝” tubing
From d to e, demand = 35,000 BTU/hr; use ½” pipe or ½” tubing
From b to f, demand = 200,000 BTU/hr; use ¾” pipe
From c to g, demand = 38,000 BTU/hr; use ½” pipe or ½” tubing
From d to h, demand = 65,000 BTU/hr; use ½” pipe or ½” tubing

A10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pipe and Tubing Selection Guide

Example 3
Determine the sizes of piping or tubing required for the 2 PSI LP-Gas installation shown.
Total first stage piping length = 26 feet; first stage regulator setting is 10psig (use Table 1 or 2 @ 30 feet)
Total 2 PSI Piping Length = 19 ft. (use Table 4 @ 20 ft. or Table 6 @ 20 ft.)
From aa to a, demand= 338,000 BTU
use ⅜” CSST or ½” copper tubing or ½” pipe
From Regulator a to each appliance:
From a to b, demand= 65,000 BTU; length = 25 ft. (Table 5),
use ½” CSST
From a to c, demand= 200,000 BTU; length = 30 ft. (Table 5)
use 1” CSST
From a to d, demand= 38,000 BTU; length = 21 ft.* (Table 5)
use ⅜” CSST *use 25 ft. column
From a to e, demand= 35,000 BTU; length = 40 ft. (Table 5)
use ½” CSST

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A11
Pipe and Tubing Selection Guide

Table 1 - First Stage Copper Tubing or Pipe Sizing


10 PSIG Inlet with a 1 PSIG Pressure Drop (Between First and Second Stage Regulators)
Maximum capacity of pipe or tubing in thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)
Size of Pipe or Length of Pipe or Tubing in Feet*
Copper Tubing in
Inches 10 20 30 40 50 60 70 80 90 100 125 150 175
⅜ 513 352 283 242 215 194 179 166 156 147 131 118 109
Copper ½ 1,060 727 584 500 443 401 369 343 322 304 270 244 225
Tubing
(O.D.)** ⅝ 2,150 1,480 1,190 1,020 901 816 751 699 655 619 549 497 457
¾ 3,760 2,580 2,080 1,780 1,570 1,430 1,310 1,220 1,150 1,080 959 869 799
½ 3,320 2,280 1,830 1,570 1,390 1,260 1,160 1,080 1,010 956 848 768 706
¾ 6,950 4,780 3,840 3,280 2,910 2,640 2,430 2,260 2,120 2,000 1,770 1,610 1,480
1 13,100 9,000 7,220 6,180 5,480 4,970 4,570 4,250 3,990 3,770 3,340 3,020 2,780
1¼ 26,900 18,500 14,800 12,700 11,300 10,200 9,380 8,730 8,190 7,730 6,850 6,210 5,710
Pipe
1½ 40,300 27,700 22,200 19,000 16,900 15,300 14,100 13,100 12,300 11,600 10,300 9,300 8,560
Size***
2 77,600 53,300 42,800 36,600 32,500 29,400 27,100 25,200 23,600 22,300 19,800 17,900 16,500
2½ 124,000 85,000 68,200 58,400 51,700 46,900 43,100 40,100 37,700 35,600 31,500 28,600 26,300
3 219,000 150,000 121,000 103,000 91,500 82,900 76,300 70,900 66,600 62,900 55,700 50,500 46,500
4 446,000 306,000 246,000 211,000 187,000 169,000 156,000 145,000 136,000 128,000 114,000 103,000 94,700
200 250 300 350 400 450 500 550 600 700 750 800 850
⅜ 101 90 81 75 70 65 62 59 56 51 50 48 46
Copper ½ 209 185 168 155 144 135 127 121 115 106 102 99 96
Tubing
(O.D.)** ⅝ 426 377 342 314 292 274 259 246 235 216 208 201 195
¾ 744 659 597 549 511 480 453 430 410 378 364 351 340
½ 657 582 528 486 452 424 400 380 363 334 321 310 300
¾ 1,370 1,220 1,100 1,020 945 886 837 795 759 698 672 649 628
1 2,590 2,290 2,080 1,910 1,780 1,670 1,580 1,500 1,430 1,310 1,270 1,220 1,180
1¼ 5,320 4,710 4,270 3,930 3,650 3,430 3,240 3,070 2,930 2,700 2,600 2,510 2,430
A Pipe
Size***
1½ 7,960 7,060 6,400 5,880 5,470 5,140 4,850 4,610 4,400 4,040 3,900 3,760 3,640
2 15,300 13,600 12,300 11,300 10,500 9,890 9,340 8,870 8,460 7,790 7,500 7,240 7,010
2½ 24,400 21,700 19,600 18,100 16,800 15,800 14,900 14,100 13,500 12,400 12,000 11,500 11,200
3 43,200 38,300 34,700 31,900 29,700 27,900 26,300 25,000 23,900 21,900 21,100 20,400 19,800
4 88,100 78,100 70,800 65,100 60,600 56,800 53,700 51,000 48,600 44,800 43,100 41,600 40,300
900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
⅜ 45 44 42 40 38 37 35 34 33 32 31 30 29
Copper ½ 93 90 88 83 79 76 73 70 68 66 64 62 60
Tubing
(O.D.)** ⅝ 189 183 178 169 161 155 148 143 138 134 130 126 122
¾ 330 320 311 296 282 270 260 250 241 234 227 220 214
½ 291 283 275 261 249 239 229 221 213 206 200 194 189
¾ 609 592 575 546 521 499 480 462 446 432 419 407 395
1 1,150 1,110 1,080 1,030 982 940 903 870 840 813 789 766 745
1¼ 2,360 2,290 2,230 2,110 2,020 1,930 1,850 1,790 1,730 1,670 1,620 1,570 1,530
Pipe
1½ 3,530 3,430 3,330 3,170 3,020 2,890 2,780 2,680 2,590 2,500 2,430 2,360 2,290
Size***
2 6,800 6,600 6,420 6,100 5,820 5,570 5,350 5,160 4,980 4,820 4,670 4,540 4,410
2½ 10,800 10,500 10,200 9,720 9,270 8,880 8,530 8,220 7,940 7,680 7,450 7,230 7,030
3 19,200 18,600 18,100 17,200 16,400 15,700 15,100 14,500 14,000 13,600 13,200 12,800 12,400
4 39,100 37,900 36,900 35,000 33,400 32,000 30,800 29,600 28,600 27,700 26,900 26,100 25,400
*Total length of piping from outlet of first stage regulator to inlet of second stage regulator (or to inlet of second stage regulator furthest away)
**Data referenced from NFPA 58 2020 table 16.1(f)
***Data referenced from NFPA 58 2020 Table 16.1(a)

Notes:
To allow for 2 PSIG pressure drop, multiply total gas demand by 0.707 and use capacities from table.
For different first stage pressures, multiply total gas demand by the following factor and use capacities from table below

First Stage Pressure PSIG Multiple By

20 0.844
15 0.912
5 1.120

A12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pipe and Tubing Selection Guide

Table 2 - First Stage Polyethylene Plastic Tubing or Pipe Sizing


10 PSIG Inlet with a 1 PSIG Pressure Drop (Between First and Second Stage Regulators)
Maximum capacity of polyethylene pipe or tubing in thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)

Size of Plastic Tubing


Length of Pipe or Tubing in Feet*
in Inches
NPS SDR 10 20 30 40 50 60 70 80 90 100 125
½ T** 7 N/A N/A 762 653 578 524 482 448 421 397 352
½*** 9.33 N/A N/A 2,140 1,840 1,630 1,470 1,360 1,260 1,180 1,120 990
¾*** 11 N/A N/A 4290 3670 3260 2950 2710 2530 2370 2240 1980
1 T** 11 N/A N/A 5,230 4,470 3,960 3,590 3,300 3,070 2,880 2,720 2,410
1*** 11 N/A N/A 7,740 6,630 5,870 5,320 4,900 4,560 4,270 4,040 3,580
1 ¼*** 11 N/A N/A 13,420 11,480 10,180 9,220 8,480 7,890 7,400 6,990 6,200
1 ½*** 11 N/A N/A 20,300 17,300 15,400 13,900 12,800 11,900 11,200 10,600 9,360
2*** 11 N/A N/A 36,400 31,200 27,600 25,000 23,000 21,400 20,100 19,000 16,800
150 175 200 225 250 275 300 350 400 450 500
½ T** 7 319 294 273 256 242 230 219 202 188 176 166
½*** 9.33 897 826 778 721 681 646 617 567 528 495 468
¾*** 11 1800 1650 1540 1440 1360 1290 1240 1140 1060 992 937
1 T** 11 2,190 2,010 1,870 1,760 1,660 1,580 1,500 1,380 1,290 1,210 1,140
1*** 11 3,240 2,980 2,780 2,600 2,460 2,340 2,230 2,050 1,910 1,790 1,690
1 ¼*** 11 5,620 5,170 4,810 4,510 4,260 4,050 3,860 3,550 3,300 3,100 2,930
1 ½*** 11 8,480 7,800 7,260 6,810 6,430 6,110 5,830 5,360 4,990 4,680 4,420
2*** 11 15,200 14,000 13,000 12,200 11,600 11,000 10,470 9,640 8,970 8,410 7,950
600 700 800 900 1000 1500 2000
½ T** 7 151 139 129 273 114 92 79
½*** 9.33 424 390 363 778 322 258 221
¾*** 11 849 781 726 1540 644 517 443 A
1 T** 11 1,030 951 884 1,870 784 629 539
N/A
1*** 11 1,530 1,410 1,310 2,780 1,160 933 798
1 ¼*** 11 2,650 2,440 2,270 4,810 2,010 1,620 1,380
1 ½*** 11 4,010 3,690 3,430 7,260 3,040 2,440 2,090
2*** 11 7,200 6,620 6,160 13,000 5,460 4,390 3,750
*Total length of piping from outlet of first stage regulator to inlet of second stage regulator (or to inlet of second stage regulator furthest away)
**Data referenced from NFPA 58 2020 Table 16.1(o)
***Data referenced from NFPA 58 2020 TIA 20-4

Notes:
T = Tube Size
To allow for 2 PSIG pressure drop, multiply total gas demand by 0.707 and use capacities from table.
For different first stage pressures, multiply total gas demand by the following factor and use capacities from table below

First Stage Pressure PSIG Multiple By

20 0.844
15 0.912
5 1.120

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A13
Pipe and Tubing Selection Guide

Table 3 - Second Stage or Integral Twin Stage Tubing or Pipe Sizing


11-In. Water Column Inlet with a 0.05-In. Water Column Drop
Maximum capacity of pipe or tubing in thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)

Size of Pipe or Length of Pipe or Tubing in Feet*


Copper Tubing in
10 20 30 40 50 60 70 80 90 100 125 150 175
Inches
⅜ 45 31 25 21 19 17 16 15 14 13 11 10 NA
Copper ½ 93 64 51 44 39 35 32 30 28 27 24 21 20
Tubing
(O.D.)** ⅝ 188 129 104 89 79 71 66 61 57 54 48 44 40
¾ 329 226 182 155 138 125 115 107 100 95 84 76 70
½ 291 200 160 137 122 110 101 94 89 84 74 67 62
¾ 608 418 336 287 255 231 212 197 185 175 155 140 129
1 1,150 787 632 541 480 434 400 372 349 330 292 265 243
1¼ 2,350 1,620 1,300 1,110 985 892 821 763 716 677 600 543 500
Pipe
1½ 3,520 2,420 1,940 1,660 1,480 1,340 1,230 1,140 1,070 1,010 899 814 749
Size***
2 6,790 4,660 3,750 3,210 2,840 2,570 2,370 2,200 2,070 1,950 1,730 1,570 1,440
2½ 10,800 7,430 5,970 5,110 4,530 4,100 3,770 3,510 3,290 3,110 2,760 2,500 2,300
3 19,100 13,100 10,600 9,030 8,000 7,250 6,670 6,210 5,820 5,500 4,420 4,420 4,060
4 39,000 26,800 21,500 18,400 16,300 14,800 13,600 12,700 11,900 11,200 9,019 9,010 8,290
200 250 300 350 400 450 500 550 600 700 750 800 850
⅜ NA NA NA NA NA NA NA NA NA NA NA NA NA
Copper ½ 18 16 15 14 13 12 11 11 10 NA NA NA NA
Tubing
(O.D.)** ⅝ 37 33 30 28 26 24 23 22 21 20 19 18 18
¾ 65 58 52 48 45 42 40 38 36 34 33 32 31
½ 58 51 46 42 40 37 35 33 32 30 29 28 27
¾ 120 107 97 89 83 78 73 70 66 64 61 59 57
A 1 227 201 182 167 156 146 138 131 125 120 115 111 107
1¼ 465 412 373 344 320 300 283 269 257 246 236 227 220
Pipe
1½ 697 618 560 515 479 449 424 403 385 368 354 341 329
Size***
2 1,340 1,190 1,080 991 922 865 817 776 741 709 681 656 634
2½ 2,140 1,900 1,720 1,580 1,470 1,380 1,300 1,240 1,180 1,130 1,090 1,050 1,010
3 3,780 3,350 3,040 2,790 2,600 2,440 2,300 2,190 2,090 2,000 1,920 1,850 1,790
4 7,710 6,840 6,190 5,700 5,300 4,970 4,700 4,460 4,260 4,080 3,920 3,770 3,640
900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
⅜ NA NA NA NA NA NA NA NA NA NA NA NA NA
Copper ½ NA NA NA NA NA NA NA NA NA NA NA NA NA
Tubing
(O.D.)** ⅝ 17 16 16 15 14 14 13 13 12 12 11 11 11
¾ 29 28 28 26 25 24 23 22 21 20 20 19 19
½ 25 25 24 23 22 21 20 19 19 18 18 17 17
¾ 53 52 50 48 46 44 42 40 39 38 37 36 35
1 100 97 95 90 86 82 79 76 74 71 69 67 65
1¼ 206 200 195 185 176 169 162 156 151 146 142 138 134
Pipe
1½ 309 300 292 277 264 253 243 234 226 219 212 206 200
Size***
2 595 578 562 534 509 487 468 451 436 422 409 397 386
2½ 948 921 895 850 811 777 746 719 694 672 652 633 615
3 1,680 1,630 1,580 1,500 1,430 1,370 1,320 1,270 1,230 1,190 1,150 1,120 1,090
4 3,420 3,320 3,230 3,070 2,930 2,800 2,690 2,590 2,500 2,420 2,350 2,280 2,220
*Total length of piping from outlet of regulator to appliance furthest away.
**Data referenced from NFPA 58 2020 Table 16.1(g)
***Data referenced from NFPA 58 2020 TIA 20-2

A14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pipe and Tubing Selection Guide

Table 4 - Maximum Capacity of CSST


2 PSIG and a Pressure Drop of 1 PSIG (Between 2 psig Service and Line Pressure Regulator)
In Thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)

Size of CSST Tubing in Length of Pipe or Tubing in Feet*


Inches**
Size EHD Flow 10 25 30 40 50 75 80 100 150 200 250 300 400 500
Designation ***
13 426 262 238 203 181 147 140 124 101 86 77 69 60 53

15 558 347 316 271 243 196 189 169 137 118 105 96 82 72
18 927 591 540 469 420 344 333 298 245 213 191 173 151 135
½
19 1,110 701 640 554 496 406 393 350 287 248 222 203 175 158
23 1,740 1,120 1,030 896 806 663 643 578 477 415 373 343 298 268
¾
25 2,170 1,380 1,270 1,100 986 809 768 703 575 501 448 411 355 319
30 4,100 2,560 2,330 2,010 1,790 1,460 1,410 1,260 1,020 880 785 716 616 550
1
31 4,720 2,950 2,690 2,320 2,070 1,690 1,630 1,450 1,180 1,020 910 829 716 638
37 7,130 4,560 4,180 3,630 3,260 2,680 2,590 2,330 1,910 1,660 1,490 1,360 1,160 1,030

39 7,958 5,147 4,719 4,116 3,702 3,053 2,961 2,662 2,195 1,915 1,722 1,578 1,376 1,237
46 15,200 9,550 8,710 7,530 6,730 5,480 5,300 4,740 3,860 3,340 2,980 2,720 2,350 2,100

48 16,800 10,700 9,790 8,500 7,610 6,230 6,040 5,410 4,430 3,840 3,440 3,150 2,730 2,450
60 29,400 18,800 17,200 14,900 13,400 11,000 10,600 9,530 7,810 6,780 6,080 5,560 4,830 4,330
2
62 34,200 21,700 19,800 17,200 15,400 12,600 12,200 10,900 8,890 7,710 6,900 6,300 5,460 4,880
*Total length of piping from outlet of regulator to inlet of 2 psig Service/Line Pressure Regulator (or to inlet of regulator furthest away)
**Data referenced from NFPA 58 2020 Table 16.1(j)
***EHD - Equivalent Hydraulic Diameter - A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing.

Notes:
1.
2.
Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds ½ psi (based on 13-in. water column outlet pressure).
DO NOT USE THIS TABLE. Consult with regulator manufacturer for pressure drops and capacity factors. Pressure drops across a regulator may vary with flow rate. A
3. CAUTION: Capacities shown in table can exceed maximum capacity for a selected regulator. Consult with regulator or tubing manufacturer for guidance.
4. Table includes losses for four 90-degree bends and two end fittings. Tubing runs with a larger number of bends and/ or fittings shall be increased by an equivalent length of tubing
according to the following equation; L-1.3n where L is additional length (ft) of tubing and n is the number of additional fittings and/or bends.
5. All entries are rounded to 3 significant digits

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A15
Pipe and Tubing Selection Guide

Table 5 - Maximum Capacity of CSST


11-in. Water Column and a Pressure Drop of 0.05-in. Water Column (Between Second Stage (Low Pressure) Regulator and Appliance Shutoff Valve)
In Thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)

Size of CSST Tubing in Length of Pipe or Tubing in Feet*


Inches**
Size EHD Flow 5 10 15 20 25 30 40 50 60 70 80
Designation ***
⅜ 13 426 262 238 203 181 147 140 124 101 86 77
15 558 347 316 271 243 196 189 169 137 118 105
½ 18 927 591 540 469 420 344 333 298 245 213 191
19 1,110 701 640 554 496 406 393 350 287 248 222
¾ 23 1,740 1,120 1,030 896 806 663 643 578 477 415 373
25 2,170 1,380 1,270 1,100 986 809 768 703 575 501 448
1 30 4,100 2,560 2,330 2,010 1,790 1,460 1,410 1,260 1,020 880 785
31 4,720 2,950 2,690 2,320 2,070 1,690 1,630 1,450 1,180 1,020 910
1¼ 37 7,130 4,560 4,180 3,630 3,260 2,680 2,590 2,330 1,910 1,660 1,490
39 7,958 5,147 4,719 4,116 3,702 3,053 2,961 2,662 2,195 1,915 1,722
1½ 46 15,200 9,550 8,710 7,530 6,730 5,480 5,300 4,740 3,860 3,340 2,980
48 16,800 10,700 9,790 8,500 7,610 6,230 6,040 5,410 4,430 3,840 3,440
2 60 29,400 18,800 17,200 14,900 13,400 11,000 10,600 9,530 7,810 6,780 6,080
62 34,200 21,700 19,800 17,200 15,400 12,600 12,200 10,900 8,890 7,710 6,900
90 100 150 200 250 300
⅜ 13 15 14 11 9 8 8
15 22 20 15 14 12 11
½ 18 44 41 31 28 25 23
19 50 47 36 33 30 26
¾ 23 90 85 66 60 53 50
A 25 102 98 75 69 61 57
1 30 169 159 123 112 99 90
N/A
31 197 186 143 129 117 107
1¼ 37 286 270 217 183 163 147
39 414 393 324 283 254 234
1½ 46 656 621 506 438 390 357
48 787 746 611 531 476 434
2 60 1,400 1,330 1,090 948 850 777
62 1,550 1,480 1,210 1,050 934 854
*Total length of piping from outlet of regulator to appliance furthest away.
**Data referenced from NFPA 58 2020 Table 16.1(k)
***EHD - Equivalent Hydraulic Diameter - A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing.

Notes:
1. Table includes losses for four 90-degree bends and two end fittings. Tubing runs with a larger number of bends and/ or fittings shall be increased by an equivalent length of tubing
according to the following equation; L-1.3n where L is additional length (ft) of tubing and n is the number of additional fittings and/or bends.
2. All entries are rounded to 3 significant digits

A16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pipe and Tubing Selection Guide

Table 6 - Copper Tubing or Schedule 40 Pipe Sizing


2 PSIG Inlet with a 1 PSIG Pressure Drop (Between 2 PSIG Service and Line Pressure Regulator)
In Thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specific Gravity Gas)

Size of Pipe or Length of Pipe or Tubing in Feet*


Copper Tubing in
Inches 10 20 30 40 50 60 70 80 90 100 125 150 175
⅜ 413 284 228 195 173 157 144 134 126 119 105 95 88
Copper ½ 852 585 470 402 356 323 297 276 259 245 217 197 181
Tubing
(O.D.)** ⅝ 1,730 1,190 956 818 725 657 605 562 528 498 442 400 368
¾ 3,030 2,080 1,670 1,430 1,270 1,150 1,060 983 922 871 772 700 644
½ 2,680 1,840 1,480 1,260 1,120 1,010 934 869 815 770 682 618 569
¾ 5,590 3,850 3,090 2,640 2,340 2,120 1,950 1,820 1,700 1,610 1,430 1,290 1,190
1 10,500 7,240 5,820 4,980 4,410 4,000 3,680 3,420 3,210 3,030 2,690 2,440 2,240
1¼ 21,600 14,900 11,900 10,200 9,060 8,210 7,550 7,020 6,590 6,230 5,520 5,000 4,600
Pipe
1½ 32,400 22,300 17,900 15,300 13,600 12,300 11,300 10,500 9,880 9,330 8,270 7,490 6,890
Size***
2 62,400 42,900 34,500 29,500 26,100 23,700 21,800 20,300 19,000 18,000 15,900 14,400 13,300
2½ 99,500 68,400 54,900 47,000 41,700 37,700 34,700 32,300 30,300 28,600 25,400 23,000 21,200
3 176,000 121,000 97,100 83,100 73,700 66,700 61,400 57,100 53,600 50,600 44,900 40,700 37,400
4 359,000 247,000 198,000 170,000 150,000 136,000 125,000 116,000 109,000 103,000 91,500 82,900 76,300
200 250 300 350 400 450 500 550 600 700 750 800 850
⅜ 82 72 66 60 56 53 50 47 45 43 41 40 39
Copper ½ 168 149 135 124 116 109 103 97 93 89 86 82 80
Tubing
(O.D.)** ⅝ 343 304 275 253 235 221 209 198 189 181 174 168 162
¾ 599 531 481 442 411 386 365 346 330 316 304 293 283
½ 529 469 425 391 364 341 322 306 292 280 269 259 250
¾ 1,110 981 889 817 760 714 674 640 611 585 562 541 523
1 2,080 1,850 1,670 1,540 1,430 1,340 1,270 1,210 1,150 1,100 1,060 1,020 985
A
1¼ 4,600 3,790 3,440 3,160 2,940 2,760 2,610 2,480 2,360 2,260 2,170 2,090 2,020
Pipe
1½ 6,890 5,680 5,150 4,740 4,410 4,130 3,910 3,710 3,540 3,390 3,260 3,140 3,030
Size***
2 13,300 10,900 9,920 9,120 8,490 7,960 7,520 7,140 6,820 6,530 6,270 6,040 5,830
2½ 21,200 17,400 15,800 14,500 13,500 12,700 12,000 11,400 10,900 10,400 9,900 9,630 9,300
3 37,400 30,800 27,900 25,700 23,900 22,400 21,200 20,100 19,200 18,400 17,700 17,000 16,400
4 76,300 62,900 57,000 52,400 48,800 45,800 43,200 41,100 39,200 37,500 36,000 34,700 33,500
900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
⅜ 36 35 34 32 31 30 28 27 26 26 25 24 23
Copper ½ 75 72 71 67 64 61 59 57 55 53 51 50 48
Tubing
(O.D.)** ⅝ 152 147 143 136 130 124 120 115 111 108 104 101 99
¾ 265 258 251 238 227 217 209 201 194 188 182 177 172
½ 235 228 222 210 201 192 185 178 172 166 161 157 152
¾ 490 476 463 440 420 402 386 372 359 348 337 327 318
1 924 807 873 829 791 757 727 701 677 655 635 617 600
1¼ 1,900 1,840 1,790 1,700 1,620 1,550 1,490 1,440 1,390 1,340 1,300 1,270 1,230
Pipe
1½ 2,840 2,760 2,680 2,550 2,430 2,330 2,240 2,160 2,080 2,010 1,950 1,900 1,840
Size***
2 5,470 5,310 5,170 4,910 4,680 4,490 4,310 4,150 4,010 3,880 3,760 3,650 3,550
2½ 8,720 8,470 8,240 7,830 7,470 7,150 6,870 6,620 6,390 6,180 6,000 5,820 5,660
3 15,400 15,000 14,600 13,800 13,200 12,600 12,100 11,700 11,300 10,900 10,600 10,300 10,000
4 31,500 30,500 29,700 28,200 26,900 25,800 24,800 23,900 23,000 22,300 21,600 21,000 20,400
*Total length of piping from outlet of regulator to inlet of 2 psig Service/Line Pressure Regulator (or to inlet of regulator furthest away)
**Data referenced from NFPA 58 2020 Table 16.1(h)
***Data referenced from NFPA 58 2020 Table 16.1(b)

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A17
Pipe and Tubing Selection Guide

Table 7: Second stage or Integral Twin Stage Polyethylene Tubing or Pipe Sizing
11 in Water Column Inlet w/ a 0.5 -in Water Column Drop
Tubing in thousand of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specify Gravity Gas)

Size of Plastic Tubing in


Length of Pipe or Tubing in Feet*
Inches
NPS SDR 10 20 30 40 50 60 70 80 90 100
½ T** 7 121 83 67 57 51 46 42 39 37 35
½*** 9.33 340 233 187 160 142 129 119 110 103 98
¾*** 11 680 486 375 321 285 258 237 221 207 196
1 T** 11 828 569 457 391 347 314 289 269 252 238
1*** 11 1,230 844 677 580 514 466 428 398 374 353
1 ¼*** 11 2,130 1,460 1,170 1,000 890 807 742 690 648 612
1 ½*** 11 3,210 2,210 1,770 1,520 1,340 1,220 1,120 1,040 978 924
2*** 11 5,770 3,970 3,180 2,730 2,420 2,190 2,010 1,870 1,760 1,660
3*** 11 16,000 11,000 8,810 7,540 6,680 6,050 5,570 5,180 4,860 4,590
4*** 11 30,900 21,200 17,000 14,600 12,900 11,700 10,800 10,000 9,400 8,900
125 150 175 200 250 300 350 400 450 500
½ T** 7 31 28 26 24 21 19 18 16 15 15
½*** 9.33 87 78 72 67 60 54 50 46 43 41
¾*** 11 173 157 145 135 119 108 99 92 87 82
1 T** 11 211 191 176 164 145 132 121 113 106 100
1*** 11 313 284 261 243 215 195 179 167 157 148
1 ¼*** 11 542 491 452 420 373 338 311 289 271 256
1 ½*** 11 819 742 683 635 563 510 469 436 409 387
2*** 11 1,470 1,330 1,230 1,140 1,010 916 843 784 736 695
3*** 11 4,070 3,690 3,390 3,160 2,800 2,530 2,330 2,170 2,040 1,920
A 4*** 11 7,900 7,130 6,560 6,100 5,410 4,900 4,510 4,190 3,930 3,720
*Total length of piping from outlet of regulator to appliance furthest away.
**Data referenced from NFPA 58 2020 Table 16.1(p)
***Data referenced from NFPA 54 2018 Table 6.3.1 (k)

Notes:
T = Tube Size
All entries are rounded to 3 significant digits

A18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pipe and Tubing Selection Guide

Table 8: Polyethylene Tubing or Pipe Sizing


2 PSIG Inlet with a 1 PSIG Pressure Drop (Between 2 PSIG Service and Line Pressure Regulator)
Tubing in thousands of BTU/hr of undiluted LP-Gases (Propane)
(Based on 1.50 Specify Gravity Gas)

Size of Plastic Tubing in


*Total length of piping from outlet of regulator to appliance furthest away.
Inches**
NPS SDR 10 20 30 40 50 60 70 80 90 100 125
½ 9.33 3,130 2,150 1,730 1,480 1,310 1,190 1,090 1,010 952 899 797
¾ 11 6,260 4,300 3,450 2,960 2,620 2,370 2,180 2,030 1,910 1,800 1,600
1 11 11,300 7,760 6,230 5,330 4,730 4,280 3,940 3,670 3,440 3,250 2,880
1¼ 11 19,600 13,400 10,800 9,240 8,190 7,420 6,830 6,350 5,960 5,630 4,990
1½ 11 29,500 20,300 16,300 14,000 12,400 11,200 10,300 9,590 9,000 8,500 7,530
2 11 53,100 36,500 29,300 25,100 22,200 20,100 18,500 17,200 16,200 15,300 13,500
3 11 147,000 101,000 81,100 69,400 61,500 55,700 51,300 47,700 44,700 42,300 37,500
4 11 284,000 195,000 157,000 134,100 119,000 108,000 99,100 92,200 86,500 81,700 72,400
150 175 200 250 300 350 400 450 500 550 600
½ 9.33 722 664 618 548 496 457 425 399 377 358 341
¾ 11 1,450 1,330 1,240 1,100 994 914 851 798 754 716 683
1 11 2,610 2,400 2,230 1,980 1,790 1,650 1,530 1,440 1,360 1,290 1,230
1¼ 11 4,520 4,160 3,870 3,430 3,110 2,860 2,660 2,500 2,360 2,240 2,140
1½ 11 6,830 6,280 5,840 5,180 4,690 4,320 4,020 3,770 3,560 3,380 3,220
2 11 12,300 11,300 10,500 9,300 8,430 7,760 7,220 6,770 6,390 6,070 5,790
3 11 33,900 31,200 29,000 25,700 23,300 21,500 12,000 18,700 17,700 16,800 16,000
4 11 65,600 60,300 56,100 49,800 45,100 41,500 38,600 36,200 34,200 32,500 31,000
650 700 750 800 850 900 950 1,000 1,100 1,200 1,300
½ 9.33 327 314 302 292 283 274 266 259 246 234 225
¾ 11 654 628 605 585 566 549 533 518 492 470 450
1 11 1,180 1,130 1,090 1,050 1,020 990 961 935 888 847 811 A
1¼ 11 2,040 1,960 1,890 1,830 1,770 1,710 1,670 1,620 1,540 1,470 1,410
1½ 11 3,090 2,970 2,860 2,760 2,670 2,590 2,520 2,450 2,320 2,220 2,120
2 11 5,550 5,330 5,140 4,960 4,800 4,650 4,520 4,400 4,170 3,980 3,810
3 11 15,400 14,700 14,200 13,700 13,300 12,900 12,500 12,200 11,500 11,000 10,600
4 11 29,700 28,500 27,500 26,500 25,700 24,900 24,200 23,500 22,300 21,300 20,400
1,400 1,500 1,600 1,700 1,800 1,900 2,000
½ 9.33 216 208 201 194 188 183 178
¾ 11 432 416 402 389 377 366 356
1 11 779 751 725 702 680 661 643
1¼ 11 1,350 1,300 1,260 1,220 1,180 1,140 1,110
N/A
1½ 11 2,040 1,960 1,900 1,840 1,780 1,730 1,680
2 11 3,660 3,530 3,410 3,300 3,200 3,110 3,020
3 11 10,100 9,760 9,430 9,130 8,850 8,590 8,360
4 11 19,600 18,900 18,200 17,600 17,100 16,600 16,200
*Total length of piping from outlet of regulator to inlet of 2 psig Service/Line Pressure Regulator (or to
inlet of regulator furthest away)
**Data referenced from NFPA 54 2018 Table 6.3.1 (l)

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A19
RegO Regulator Designs

RegO LP-Gas Regulators have been designed to give Molded Diaphragm Assembly
outstanding performance and dependability with a Molded synthetic rubber with a tough, flexible fabric
minimum of maintenance. gives a super sensitive response in a temperature
range of -40º to +165ºF. Molded diaphragm seals in a
groove between the body and bonnet.
Nozzle Orifice
Replaceable and precision machined to prevent scoring of the Diaphragm Plate
seat disc. Rigid diaphragm plate transmits pressure variations to
Seat Disc control linkage.
Replaceable, resilient construction gives sure closing at lock up Relief Valve
pressure. Straight line seat disc to nozzle operation provides It is built in and tamper resistant. Large bonnet vent
even seat disc wear and positive lock up. allows high capacity relief on second stage regulators.
Pivot Pin Bonnet Cap
Fully enclosed in regulator body. Bonnet cap incorporates travel stop to help control
Control Linkage downstream pressure in the unlikely event of a
Provides quick response to diaphragm movement; moves directly regulator malfunction.
perpendicular to nozzle orifice to meter gas flow, gives positive Large Bonnet Vent
closure and reduces seat disc wear. Large vent is equipped with protective screen and
Built-In Pressure Tap threaded for ¾” F. NPT vent piping. Large vent helps
Provides a convenient way to check downstream pressure on prevent ice from building up and blocking the vent
both high and low pressure models. during inclement weather. The regulator should be
installed with vent down and the vent protected
Body & Bonnet against blockage.
Painted, heavy-duty zinc resists corrosion and gives long-life
protection, even under “salty air” conditions.

Laser Engraved Bonnet


New bonnet design features laser- engraved information
that is easy to see and matches available stickers for gas
check and record keeping. *Patent Pending

Easy to Turn Adjusting Screw


We redesigned our adjusting screw to be easily turned.

A
⅛” pressure plug ports
Our ⅛” pressure plug ports conform to 7/16” hex wrenches.

Typical of the 1580™ Industrial High


Pressure Regulators
The pounds-to-pounds, industrial regulator gives higher delivery pressure as tank pressure
decreases, thus permitting full use of the gas in the tank. Most units are field adjustable to Adjusting Assembly
Large handle with lock-nut
meet changing conditions. release allows easy resetting
of delivery pressure.
Connections
Machined and threaded into the body forging; also includes ¼” NPT pressure
gauge ports.

Seat Disc
Synthetic rubber assembly attached directly to the diaphragm assembly to ensure
proper movement and regulation.

Back Cap Spring


Provides added upward force to help provide a positive lock-up.
Sensitivity
In those cases where there is a choice of delivery pressure ranges,
the lowest spring range which will fulfill your requirements is
recommended because the sensitivity of a regulator decreases as the
range of the adjusting spring increases.
Integral O-Ring
Relief Valves Minimizes tendency to
Most high pressure regulators are not equipped with integral relief vibrate or hum under
valves. For certain applications where it is desirable to protect extreme loads.
equipment downstream of the regulator, relief valves must be
installed in the line.

A20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO Regulators Installation and Service Tips*

Why are the inlet nozzles reverse thread?


• Inlet nozzles are reverse threaded to allow for removal and service of
the seat disc and inlet nozzle, when debris has affected the regulators
performance. The seat disc and inlet nozzle can be cleaned and returned
back to normal service.

Regulator Installation Tips Inlet Nozzle


• Ensure your inlet nozzle is tightened securely into the body.

• Use back up wrenches when installing a new regulator to ensure the inlet nozzle
does not loosen.

• Install new pigtails when installing a new regulator.

• Do not use excess pipe sealant, as it can move downstream and affect regulator
performance.

• Install the regulator 12-18” off the ground and above snow accumulation.

• When regulators are not installed under a protective cover or tank lid.

• Install with the vent pointed vertically downwards.


Seat Disc
• If seasonal temperatures periodically reach -20 F, or colder the first stage
regulator should not be set higher than 10 PSIG.

• If seasonal temperatures periodically reach -35 F, or colder the first stage


regulator should not be set higher than 5 PSIG.

• Regulator must be vented 5 feet from relief discharge, any source of ignition, or
mechanical air intake, and 3 feet minimum from any building opening. A
• Regulator vent must be above highest probable water level on underground tank
installations.

• When installing regulators at a container connection, ensure the regulator is


placed above the container connection to ensure any liquid droplets fall back into
the container.

Regulator Service Tips


• Check regulator vents for obstructions.
Installed
• Make sure the vent screen and suppressor are properly in place. above highest
probable
• Ensure your inlet nozzle is tightened securely into the body.
water level
• For high lock-up, or creep, check the inlet nozzle and seat disc for debris. Clean or
replace the inlet nozzle and seat disc, reinstall and recheck your lock-up.

• When available use Presto-Tap® gauges for leak checks to avoid any debris moving
from the regulators pigtail into the system.

• Make sure the regulator is properly selected for the BTU load and system demand.

10 25
REGO REGO REGO

100% Installed
TESTED higher than
YEAR YEAR
container
™ WARRANTY SILVER SERVICE LIFE
connection

*Installation tips and guidelines referenced from NFPA 58 2020 and NFPA 54 2021.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A21
RegO Regulator Coding Guide

Regulator Application Guide Example 1


Type of System BTU/HR Suggested Regulator First Stage in a Two Stage System
First Stage in a 1,500,000 LV3403TR Series LV4403TR9 – Red color = first stage Regulator
Two Stage System “LV” = large vent
2,500,000 LV4403SR Series
“4403” = 1st Stage Regulator body
Second Stage in a 450,000 LV3403B Series “T” = 10 PSIG outlet
Two Stage System 935,000 LV4403B Series “R” = Integral internal relief valve
LV4403BD Series “9” = F. POL Inlet X ½” F. NPT Outlet
1,000,000 LV4403BRA Series LV4403SR9 has a 5 PSI outlet pressure
LV4403BRAD Series
1,600,000 LV5503B4/B6
LV5503B4D/B6D Series Example 2
2,300,000 LV5503B8 Second Stage in a Two Stage System
LV5503B8D Series
LV4403B46RD - Brown color = second stage regulator
Second Stage in a 1,000,000 LV4403Y Series “LV” = large vent
2 PSIG System LV4403YD Series
“4403” = 2nd Stage Regulator body
2,200,000 LV5503Y Series “B” = 11” water column outlet pressure
LV5503YD Series
“4” = ½” F.NPT inlet
Integral Twin Stage 450,000 LV404B34/39 Series “6” = ¾” F.NPT outlet
600,000 LV404B4/9 Series “R” = rear outlet
Integral Twin Stage 650,000 LV404Y39 “D” = Dielectric Inlet
2 PSIG Delivery 800,000 LV404Y9 LV4403B66D has a straight-thru body with a ¾” F.NPT
Automatic 400,000 7525B34 Series inlet/outlet
Changeover 450,000 7525B4 Series Example 3
Regulator Coding Guide Second Stage in a Two Stage System
Body Description LV5503B6- Brown color = second stage regulator
LV Large Vent “LV” = large vent
“5503” = 2nd Stage Regulator body
404 Twin Stage Regulator body
“B” = 11” water column outlet pressure
3403 Second Stage Regulator body
“6” = ¾” F.NPT inlet and outlet
4403 1st or Second Stage Regulator body “8” = 1” F. NPT outlet
A 5503
7525
Second Stage Regulator body
Twin Stage Automatic Changeover body
LV5503B8 has a ¾” F.NPT inlet and a 1” F.NPT outlet

D* Dielectric inlet
R Integral Relief Valve (1st Stage Only)
Example 4
R* Rear Outlet Second Stage in a 2 PSIG System
RA* Right Angle LV5503Y6 - Blue color = 2 PSIG regulator
RAB* Right Angle with Bracket “LV” = large vent
Outlet Pressure “5503” = 2nd Stage Regulator body
“Y” = 2 PSIG outlet pressure
B 11’ w.c. Outlet Pressure “6” = ¾” F.NPT inlet and outlet
L Lower than 11’ w.c. Special Setting “8” = 1” F. NPT outlet
H Higher than 11’ w.c. Special Setting LV5503Y8 has a ¾” F.NPT inlet and a 1” F.NPT outlet
G 15” w.c. Outlet Pressure Agriculture Setting
Y 2 PSIG Outlet Pressure
S 5 PSIG Outlet Pressure Example 5
T 10 PSIG Outlet Pressure Integral Twin Stage
Vent Positions**
LV40B39 – Brown color = Integral Twin stage Regulator
“LV” = large vent
VI Vent Over Inlet “404” = twin stage regulator body
VO Vent Over Outlet “B” = 11” water column outlet pressure
V3 Vent at 3:00 O’clock Position “39” = F. POL Inlet X ½” F. NPT Outlet
V9 Vent at 9:00 O’clock Position LV404B34 has a ¼” F.NPT inlet and a ½” F. NPT outlet
Inlet/Outlet Connection Sizing
1 ½” M. Flare inlet
2 ¼” F. NPT
Example 6
3 ⅜” M. Flare inlet
Integral Twin Stage 2 PSIG
34 ¼” F. NPT inlet X ½” F. NPT Outlet LV40Y9 – Blue color = Integral Twin stage Regulator
39 F. POL Inlet X ½” F. NPT Outlet “LV” = large vent
4 ½” F. NPT 404” = twin stage regulator body
5 ⅝” M. Flare inlet “Y” = 2 psig outlet pressure
6 ¾” F. NPT “9” = F. POL Inlet X ½” F. NPT Outlet
8 1” F. NPT LV404Y39 has a F. POL Inlet and a ½” F. NPT Outlet
9 F. POL Inlet X ½” F. NPT Outlet
96 F. POL Inlet X ¾” F. NPT Outlet
*2nd Stage regulators only.
**Standard vent positions are over the outlet on 1st Stage and Twin-Stage regulators, and vent over the inlet on 2nd stage regulators unless otherwise specified with the corresponding abbreviations.

A22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO Regulator Selection

Type of System BTU/hr. kg/hr. Suggested Regulator


1,500,000 32 LV3403TR Series

First Stage in a Two Stage


System 2,500,000 54 LV4403SR Series
LV4403TR Series

LV3403B Series
450,000 10
LV3403BR Series
LV4403B Series
935,000 20
Second Stage in a Two LV4403BD Series
Stage System LV5503B4/B6
1,600,000 34
LV4403B4D/B6D
LV5503B8
2,300,000 49
LV5503B8D
1,000,000 21 LV4403Y4/Y46R

Second Stage in a 2 PSIG


System 2,200,000 47 LV5503Y6/Y8

450,000 9 LV404B34/39 Series


A

Integral Twin Stage


600,000 11 LV404B4/B9 Series

800,000 17 LV404Y9

Integral Twin Stage 2 PSIG


Delivery 650,000 14 LV404Y39

400,000 8 7525B34 Series

Automatic Changeover
450,000 9 7525B4 Series

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A23
Compact First Stage Regulators
LV3403TR

Application
Ideal for use as a first stage regulator on any domestic size ASME or
DOT container in propane gas installations requiring up to 1,500,000
BTU’s per hour. The regulator is factory set to reduce container
pressure to an intermediate pressure of approximately 10 PSIG
(0.69 BARG).

Features
• Compact design can be connected to a service valve using
either a POL adapter or a RegO product pigtail.

• Large threaded ⅜” F.NPT bonnet vent can easily be piped-away


underground installations without the need of glue kits or extra
adapters.
LV3403TR
• Non Adjustable

• Large flow orifice resists freeze ups due to water concentration in


LPG vapor.
LV3403TR9V9
• Design provides for good flow regulation at both high and low
container pressures.

• Built in relief valve and travel stop comply with NFPA 58 over
pressure requirements.

• Incorporates ⅛” F.NPT downstream pressure tap for an easy


inline check of the regulator’s delivery pressure.

• Molded diaphragm provides an o-ring type seal between the 3.865”


body and bonnet.

A • Body and bonnet are assembled in the USA using the unique,
patented RegUlok seal system.

• Fully painted in brilliant red for complete corrosion protection.


3.56”

• Mounting bracket available as an accessory: part number 3403-31. 12

• Temperature Range: -40°F to +165°F


Initial Setting
PSI

11
DELIVERY PRESSURE

Materials 150 PSIG INLET


G

Body.............................................................................................Zinc
100 PSIG INLET
Bonnet..........................................................................................Zinc 10

Spring......................................................................................... Steel 50 PSIG INLET


Seat Disc..................................................................Resilient Rubber
Diaphragm............................Integrated Fabric and Synthetic Rubber 9
25 PSIG INLET

25 10
REGO REGO

8
CFH/hr 100 20 30 40 50 60 70
YEAR YEAR BTU/hr 250,000 500,000 750,000 1,000,000 1,250,000 1,500,000 1,750,00
FLOW PROPANE
SILVER SERVICE LIFE WARRANTY

Ordering Information
Factory Delivery Vapor Capacity BTU/
Part Number Inlet Connection Outlet Connection Orifice Size Bonnet Vent Position
Pressure hr Propane*
LV3403TR Over Outlet
¼” F. NPT Opposite Gauge
LV3403TRV9 10 PSIG @ 50
PSIG Inlet (0.69 Port 1,500,000 BTU/hr
½” F. NPT #16 Drill (4.49mm)
LV3403TR9 Bar @ 3.44 Bar Over Outlet (32 KG/hr)
inlet)
F. POL Opposite Gauge
LV3403TR9V9
Port
*Maximum flow based on inlet pressure 20 PSIG(1.4 bar) higher than the regulator setting and delivery pressure 20%
lower than the regulator setting and delivery pressure 20% lower than the setting.

A24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
High Pressure First Stage Regulators
LV4403SR and TR Series

Application
Provides accurate first stage regulation in two-stage bulk tank
systems. Reduce tank pressure to an intermediate pressure of 5 to
10 PSIG (0.34 to 0.69 BARG). Also used to supply high pressure
burners for applications like industrial furnaces or boilers. Also
incorporated in multiple cylinder installations.
2¼"

Features
• Incorporate integral relief valves for added system protection.
• Large vent helps prevent blockage and has ¾” F.NPT thread for 71⁄8"
vent piping.
• Bonnet vent positioned over outlet to avoid icing and
contamination by foreign material. 4½"
• Unique bonnet vent profile designed to minimize vent freeze over 5¼"
when properly installed.
• Replaceable valve orifice and valve seat disc.
• Straight-line valve closure reduces wear on seat disc.
• Large molded diaphragm is extra sensitive to pressure changes.
• Built in pressure tap has plugged ⅛” F.NPT outlet. LV4403 Series
• Plug can be removed with a 3⁄16” hex allen wrench.
• Extra long lever arm provides uniform delivery pressure. 37⁄8" 1½"
• Brilliant red finish.
• Temperature Range: -40°F to +165°F LV4403SR
150 PSIG Inlet
Initial Setting 125 PSIG Inlet
Materials

Delivery Pressure
7 100 PSIG Inle
t
6
Body ............................................................................ Die Cast Zinc

PSIG
5
Bonnet ......................................................................... Die Cast Zinc 4
Nozzle Orifice .......................................................................... Brass 50 PSIG Inlet
3
10 PSIG Inlet 25 PSIG Inlet
Spring ....................................................................................... Steel
Valve Seat Disc ...................................................... Resilient Rubber
CFH/hr. 100 200 300 400 500 600 700 800 900 1000
Diaphragm .......................... Integrated Fabric and Synthetic Rubber BTU/hr. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
LV4403TR
A

25 10
150 PSIG Inlet
REGO REGO 12 Initial Setting 125 PSIG Inlet
Delivery Pressure

11 100 PSIG Inlet


10
PSIG

9
8
YEAR YEAR 7
15 PSIG Inlet 50 PSIG Inlet
SILVER SERVICE LIFE WARRANTY 25 PSIG Inlet
CFH/hr. 100 200 300 400 500 600 700 800 900 1000
BTU/hr. 500,000 1,000,000 1,500,000 2,000,000 2,500,000
Ordering Information
Adjustment Bonnet Vent Vapor Capacity
Part Number Inlet Connection Outlet Connection Orifice Size Factory Delivery Pressure
Range Position BTU/hr Propane*
LV4403SR4 Over Outlet
5 PSIG @ 50 PSIG inlet 1-5 PSIG
LV4403SR4VI (0.34 Bar @ 3.44 Bar inlet) (0.069-0.34 bar) Over Inlet
LV4403TR4 ½” F. NPT Over Outlet
LV4403TR4V9 10 PSIG @ 50 PSIG Inlet 5-10 PSIG 9 o'clock
(0.69 Bar @ 3.44 Bar inlet) (0.34 - 0.69 Bar)
LV4403TR4VI ½” F. NPT Over Inlet

LV4403SR9 5 PSIG @ 50 PSIG inlet 1-5 PSIG Over Outlet


(0.34 Bar @ 3.44 Bar inlet) (0.069-0.34 bar)
LV4403TR9 Over Outlet
10 PSIG @ 50 PSIG Inlet 5-10 PSIG 2,500,000
LV4403TR9V9 ¼” (6.25mm) (0.69 Bar @ 3.44 Bar inlet) (0.34 - 0.69 Bar) 9 o'clock BTU/hr
F. POL (53 KG/hr)
LV4403SR96 Over Outlet
5 PSIG @ 50 PSIG inlet 1-5 PSIG
LV4403SR96VI (0.34 Bar @ 3.44 Bar inlet) (0.069-0.34 bar) Over Inlet
¾” F. NPT
LV4403TR96 Over Outlet
10 PSIG @ 50 PSIG Inlet 5-10 PSIG
LV4403TR96V9 (0.69 Bar @ 3.44 Bar inlet) (0.34 - 0.69 Bar) 9 o'clock
LV4403SR66 Over Outlet
5 PSIG @ 50 PSIG inlet 1-5 PSIG
LV4403SR66VI (0.34 Bar @ 3.44 Bar inlet) (0.069-0.34 bar) Over Inlet
¾” F. NPT ¾” F. NPT
LV4403TR66 10 PSIG @ 50 PSIG Inlet 5-10 PSIG Over Outlet
(0.69 Bar @ 3.44 Bar inlet) (0.34 - 0.69 Bar)
*Maximum flow based on inlet pressure 20 PSIG(1.4 bar) higher than the regulator setting and delivery pressure 20% lower than the regulator setting
and delivery pressure 20% lower than the setting.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A25
Low Pressure Second Stage Regulators - Standard Settings
LV4403B Series

Application
Designed to reduce first stage pressure of 5 to 20 PSIG (0.34 to 1.38
BARG) down to burner pressure, normally 11” w.c. Ideal for medium
commercial installations, multiple cylinder installations and normal
domestic loads.

Features
• Large vent helps prevent blockage and has ¾" F.NPT for vent piping.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 2 PSIG with the seat disc removed.

• Incorporates integral relief valves.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure reduces wear on seat disc.

• Unique bonnet vent profile minimizes vent freeze over when


properly installed. LV4403B Series

• Large molded diaphragm is extra sensitive to pressure changes.


LV4403BR
• Built in pressure tap has plugged ⅛ F.NPT outlet. Plug can be
removed with a 3⁄16" hex allen wrench.

• Select brown finish.


3⅞”
• Temperature Range: -40°F to +165°F

Backmount Design
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.

Materials 17/16”
A Body ............................................................................ Die Cast Zinc
Bonnet ......................................................................... Die Cast Zinc
Nozzle Orifice .......................................................................... Brass
Spring ....................................................................................... Steel 75/32”
Valve Seat Disc ...................................................... Resilient Rubber
Diaphragm .......................... Integrated Fabric and Synthetic Rubber
5¼”

LV4403B

3⅞”

25 10
REGO REGO
1½”

YEAR YEAR 4½” 2¼”


SILVER SERVICE LIFE WARRANTY 7⅛”
Ordering Information
Vapor Capacity
Factory Delivery Adjustment Bonnet Vent
Part Number Inlet Connection Outlet Connection Orifice Size BTU/hr
Pressure Range Position
Propane****
LV4403B4* ½” F. NPT
LV4403B46** ½” F. NPT 11” w.c. at
¾” F. NPT 10 PSIG 9” to 13”
LV4403B46R*** #28 Drill 935,000 BTU/hr
Inlet w.c. (22.4 to Over Inlet
(3.57mm) (20 KG/hr)
(27.4 mbar at 32.3 mbar)
LV4403B66**
0.69 bar)
¾” F. NPT ¾” F. NPT
LV4403B66R***
*Available in vent over outlet (VO) and vent at 9 O’clock(V9)
**Available in vent over outlet (VO), vent at 3 O’clock(V3) and vent at 9 O’clock(V9)
***Backmount design
****Maximum flow based on 10 PSIG(0.69 bar) inlet and 9” w.c.(22.4 mbar) delivery pressure.
A26 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Dielectric Second Stage Regulators
LV4403BD Series

Application
RegO’s Dielectric second stage regulators are designed to reduce
first stage pressure normally 10 PSIG (0.69 BARG) down to burner
pressure, normally 11” w.c. and are ideal for medium commercial
installations, multiple cylinders installations and normal domestic
loads.

RegO Dielectric second stage regulators are engineered to isolate


potential electrical current from metallic piping before entering a
building. The use of a separate dielectric union is not necessary
because the regulator contains a dielectric union as part of the inlet
assembly. Available in both SAE Flare and F.NPT inlet connection.

Features
• F. NPT Dielectric Union is made of Brass
• M. SAE Flare inlet connection made of solid Brass
• All second stage features are the same as LV4403B Series
• Temperature Range: -40°F to +165°F LV4403BD Series
M.
Flare

25 10
REGO REGO
3¾”

YEAR YEAR
SILVER SERVICE LIFE WARRANTY NPT
3¼”

Ordering Information “A”


Bonnet A
Inlet Outlet Inlet Adjustment Vapor Capacity BTU/hr
Part Number Orifice Size Factory Delivery Pressure Vent
Connection Connection Material Range Propane ****
Position
⅜” M. Flare = 3
LV4403B3D ½” F. NPT
LV4403B36D ¾” F. NPT # 28 Drill 935,000 BTU/hr
LV4403B3RD* ½” F. NPT (3.57mm) 9” to 13” (20 KG/hr)
11” w.c. at 10 PSIG Inlet Over
⅜” M Flare Brass w.c. (22.4 to
LV4403B36RD* (27.4 mbar at 0.69 bar) Inlet
32.3 mbar)
LV4403B36RAD** ¾” F. NPT 3
/16” 1,000,000 BTU/hr
LV4403B36RABD*** (4.78mm) (21 KG/hr)
½” M. Flare = 1
LV4403B1D ½" F. NPT
LV4403B16D # 28 Drill
(3.57mm) 935,000 BTU/hr
9” to 13” (20 KG/hr)
LV4403B16RD* 11” w.c. at 10 PSIG Inlet Over
½" M Flare Brass w.c. (22.4 to
¾" F. NPT (27.4 mbar at 0.69 bar) Inlet
LV4403B16RAD** 32.3 mbar)
3
/16”
LV4403B16RABD*** (4.78mm) 1,000,000 BTU/hr
(21 KG/hr)
⅝" M.Flare = 5
LV4403B5D ½" F. NPT
LV4403B56D # 28 Drill
(3.57mm) 935,000 BTU/hr
LV4403B56RD* 9” to 13” (20 KG/hr)
11” w.c. at 10 PSIG Inlet
⅝" M Flare Brass w.c. (22.4 to Over
LV4403B56RAD** ¾" F. NPT (27.4 mbar at 0.69 bar)
3/16” 32.3 mbar) Inlet
LV4403B56RABD*** (4.78mm) 1,000,000 BTU/hr
(21 KG/hr)
½"- ¾" F. NPT Female Union
LV4403B4D ½" F.NPT
½" F.NPT
LV4403B46D
LV4403B66D # 28 Drill 935,000 BTU/hr
¾" F. NPT (3.57mm) 9” to 13” (20 KG/hr)
11” w.c. at 10 PSIG Inlet Over
LV4403B46RD* ½" F. NPT Brass w.c. (22.4 to
¾" F. NPT (27.4 mbar at 0.69 bar) Inlet
LV4403B66RD* 32.3 mbar)
LV4403B66RAD** ¾" F. NPT 3
/16” 1,000,000 BTU/hr
LV4403B66RABD*** (4.78mm) (21 KG/hr)
* Backmount Design.
** Right Angle Design
*** Right Angle with Bracket
**** Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c.(22.4 Mbar) delivery pressure.
100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A27
Low Pressure Second Stage Regulators - Special Settings
LV4403H Series

Application
Designed to reduce first stage pressure of 5 to 10 PSIG down to
pressure higher than 11” water column, the actual pressure setting
is specified in the table below. These regulators are designed for
installations where the appliances require pressures greater than 11
inches w.c.

Features
• Large vent helps prevent blockage and has ¾" F.NPT for vent
piping.
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 2 PSIG with the seat disc removed.
• Incorporates integral relief valves.
• Replaceable valve orifice and valve seat disc.
• Straight line valve closure reduces wear on seat disc.
• Unique bonnet vent profile minimizes vent freeze over when
properly installed.
• Large molded diaphragm is extra sensitive to pressure changes.
• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug can be LV4403H Series
removed with a 3⁄16" hex allen wrench.
• Select brown finish.
• Temperature Range: -40°F to +165°F LV4403H

Materials
Body ............................................................................ Die Cast Zinc
Bonnet ......................................................................... Die Cast Zinc
Nozzle Orifice .......................................................................... Brass
A Spring ....................................................................................... Steel
Valve Seat Disc ...................................................... Resilient Rubber
Diaphragm .......................... Integrated Fabric and Synthetic Rubber

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Inlet Outlet Bonnet Vent Vapor Capacity
Part Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range Position BTU/hr. Propane**

LV4403H222 7/32” 22” w.c. at 10 PSIG Inlet 15-35 w.c.


¼” F.NPT (5.56mm) (54.7 mbar at 0.69 bar) (37.3-87.1 mbar)
LV4403H414 14” w.c. at 10 PSIG inlet 12.5-19 w.c.
½” F.NPT (34.8 mbar at 0.69 bar) (31.1-47.3 mbar)
LV4403H420 20” w.c. at 10 PSIG inlet 15-35 w.c,
(49.8 mbar at 0.69 bar) (37.3-87.1 mbar)
700,000
½” F.NPT 14” w.c. at 10 PSIG inlet 12.5-19 w.c. Inlet (15 kg/hr)
LV4403H4614 #28
(3.57mm) (34.8 mbar at 0.69 bar) (31.1-47.3 mbar)
15-35 w.c.
LV4403H4620 20” w.c. at 10 PSIG inlet
¾” F.NPT (37.3-87.1
(49.8 mbar at 0.69 bar) mbar)
LV4403H6614 14” w.c. at 10 PSIG inlet 12.5-19 w.c.
¾” F.NPT (34.8 mbar at 0.69 bar) (31.1-47.3 mbar)
* Maximum flow based on 10 PSIG (0.69 BARG) inlet 20% drop in delivery pressure
A28 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Compact “Back-Mount” Regulator
LV3403BR Series

Application
The LV3403BR Back Mount Regulator is designed to reduce first
stage pressure of 5-10 PSIG down to burner pressure normally 11”
w.c. Designed as a second stage regulator for smaller applications
with flow requirements up to 450,000 BTU/hr. and are ideal for
homes, mobile homes, and cottages.

Features
• Built in ⅛” F.NPT pressure taps on both regulator inlet and
outlet side of the regulator. Plugs can be removed with a 3/16” hex
allen wrench.

• Large vent helps prevent vent blockage, it is tapped for ⅜” F.NPT


for vent pipe away applications.

• With 15 PSIG inlet pressure, the regulator is designed to not pass


more than 2 PSIG downstream with the seat disc removed per UL
144 specifications.

• Incorporates an integral relief valve per UL 144 specifications.

• Unique bonnet vent profile minimizes vent freeze over.

• Compact design saves space.


LV3403BR Series
• Temperature Range: -40°F to +165°F

Materials
Body.............................................................................................Zinc
Bonnet..........................................................................................Zinc
Spring......................................................................................... Steel
Seat Disc..................................................................Resilient Rubber
Diaphragm............................Integrated Fabric and Synthetic Rubber A

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

LV3403B Series
14
13
Inial
Inches of Water Column

12
Delivery Pressure

15 PSIG Inlet
11
10 1” 33/8”
9
8
5 PSIG Inlet 8 PSIG Inlet 10 PSIG Inlet
7
6
CF/HR 0 50 100 150 200 250
BTU/HR 125,000 250,000 375,000 500,000 625,000

Ordering Information
Factory Delivery Pressure
Outlet Adjustment Bonnet Vent Vapor Capacity
Part Number Inlet Connection Connection Orifice Size w.c. barg Range Position BTU/hr *
LV3403B44R ½” F.NPT
½” F.NPT 11” w.c. at 10 psig 27.37 MBars at 9” to 13”
LV3403B46R
/ ”
7 32
Inlet 0.69 barg Inlet w.c. (22.4 to Over Inlet 450,000
¾” F.NPT 32.35 MBars)
LV3403B66R ¾” F.NPT
* Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c.(22.4 Mbar) delivery pressure

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A29
Compact Second Stage Regulator for LP-Gas
LV3403B4

Application
The LV3403B4 is designed to reduce first stage pressure of 5-20
PSIG down to burner pressure normally 11” w.c. Designed as a
second stage regulator for smaller applications with flow requirements
up to 450,000 BTU’s/hr, they are ideal for homes, mobile homes, and
cottages.

Features
• Large vent helps prevent vent blockage, it is tapped for 3/8”F.NPT
for vent piping.

• With 15 PSIG inlet pressure, the regulator is designed to not pass


more than 2 PSIG downstream with the seat disc removed, per
NFPA 58.

• Incorporates an integral relief valve

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.

• Compact design saves space.

• Built in pressure taps ⅛” F.NPT on both regulator inlet and


downstream side of the regulator. Plugs can be removed with a
3/16” hex Allen wrench. LV3403B4 Series
• Select brown finish.

• Temperature Range: -40°F to +165°F


Straight Through Design
Straight Through Design
Straight Through Design
3.99”3.99”
A
Materials
Body.............................................................................................Zinc
Bonnet..........................................................................................Zinc
Spring......................................................................................... Steel
Seat Disc..................................................................Resilient Rubber 4.06”
4.06”
Diaphragm............................Integrated Fabric and Synthetic Rubber

4.31”
LV3403B Series ● Downstream Pressure Tap 4.31”
14 ● Inlet
● Pressure Tap Pressure
Downstream ⅛” F.NPTTap
13 ● Inlet Pressure Tap ⅛” F.NPT
Inial
Inches of Water Column

12
Delivery Pressure

15 PSIG Inlet
11
10
9

25 10
8
5 PSIG Inlet 8 PSIG Inlet 10 PSIG Inlet
REGO REGO
7
6
CF/HR 0 50 100 150 200 250
BTU/HR 125,000 250,000 375,000 500,000 625,000
YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Inlet Outlet Bonnet Vent Vapor Capacity
Part Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range Position BTU/hr Propane*
LV3403B44R ½” F.NPT
½” F.NPT 9” to 13”
LV3403B46R 7/32” 11” w.c. at 10 PSIG Inlet 450,000
w.c. (22.4 to Over Inlet
¾” F.NPT (5.56mm) (27.4 mbar at 0.69 bar) (9.49 kg/hr)
LV3403B66R
¾” F.NPT 32.3 mbar)
*Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c.(22.4 Mbar) delivery pressure

A30 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Low Pressure Second Stage Regulators
LV4403B66RA Series

Application
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure, normally 11” w.c. Ideal for medium commercial
installations, vapor meter installations and normal domestic loads.

Features
• 90 degree right angle inlet to outer connection for meter or
standard installations.

• Large vent helps to prevent blockage and has ¾” F. NPT for vent
piping.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 2 PSIG with the seat disc removed.
Attached to Vapor Meter
• Replaceable valve orifice and valve seat.

• Straight line valve closure reduces wear on seat disc

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.

• Large molded diaphragm is extra sensitive to pressure changes.


9 O’clock
• Built in pressure tap has plugged ⅛” F. NPT outlet. Plug can be LV4403B66RA Vent
Series
Position
removed with a 3/16” hex allen wrench. w/ Mounting Bracket
• Select Brown Finish 9 O’clock 90º 23/16”
Vent Position
• Temperature Range: -40°F to +165°F
90º 23/16”
Right Angle Design
Can mount directly to vapor meter. It is also suitable for mounting
directly to the house piping. It will retrofit into existing installations that
A
are currently using a 90 degree, right angle regulator.

Materials
Body ............................................................................ Die Cast Zinc
Bonnet ......................................................................... Die Cast Zinc 5¼”
Nozzle Orifice .......................................................................... Brass
Spring ....................................................................................... Steel
Valve Seat Disc ...................................................... Resilient Rubber 5¼”
Diaphragm .......................... Integrated Fabric and Synthetic Rubber
3⅞”

3⅞”

7¼”

25 10
REGO REGO

7¼”
YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Factory Delivery Bonnet Vent Vapor Capacity BTU/hr.
Part Number Inlet Connection Outlet Connection Orifice Size Pressure Adjustment Range Position Propane*

LV4403B66RA
11” w.c. at 9” to 13”
10 PSIG Over Inlet
LV4403B66RAB**
3
/16” w.c. 1,000,000 BTU/hr
¾” F. NPT ¾” F. NPT Inlet
(4.78mm) (22.4 to 32.3 (21 KG/hr)
(27.4 mbar at mbar)
LV4403B66RA9 0.69 bar) 9 O'clock
* Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c.(22.4 Mbar) delivery pressure.
** Mounting Bracket Included.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A31
Low Pressure Second Stage Regulators - Standard Settings
LV5503B Series

Application
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure,normally 11” w.c. Ideal for larger commercial and
industrial applications, multiple cylinder installations and large
domestic systems.

Features
• Incorporates integral relief valve.

• With 15 PSIG inlet pressure, regulator is designed to not


pass more than 2 PSIG with the seat disc removed.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure saves wear on seat disc and


orifice.

• Built in pressure tap has plugged⅛” F.NPT outlet. Plug


can be removed with a 3⁄16” hex allen wrench.

• Large bonnet vent profile minimizes vent freeze over when


properly installed. LV5503B Series

• Extra long lever arm for uniform delivery pressure.

• Large diaphragm is extra sensitive to pressure changes.

• Temperature Range: -40°F to +165°F

Materials
Body (LV5503B Series ...................................... Die Cast Aluminum
Bonnet (LV5503B Series) .................................. Die Cast Aluminum
A Nozzle Orifice ......................................................................... Brass
Spring ...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Part Inlet Outlet Bonnet Vent Vapor Capacity BTU/hr.
Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range Position Propane**
LV5503B4* ½” F. NPT ¼” 1,600,000
¾” F. NPT 9” to 13” w.c.
LV5503B6* (6.25mm) 11” w.c. at 10 PSIG Inlet (34 kg/hr)
(22.4 to 32.3 Over Inlet
¾” F. NPT (27.4 mbar at 0.69 bar)
9/32” mbar) 2,300,000
LV5503B8* 1” F. NPT (7.14mm) (48 kg/hr)
*Available in vent over outlet (VO), vent at 3 O’clock(V3) and vent at 9 O’clock(V9)
** Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c. (22.4 mbar) delivery pressure.

A32 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Dielectric Low Pressure Second Stage Regulators - Standard Settings
LV5503BD Series

Application
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure,normally 11” w.c. Ideal for larger commercial and
industrial applications, multiple cylinder installations and large (Ø7.483)
domestic systems.
(Ø7.483)
RegO Dielectric second stage regulators are engineered to isolate
potential electrical current from metallic piping before entering a
building. The use of a separate dielectric union is not necessary SI
/ FLA
I
MM A B L E .
V E N J UR Y B Y Q F E
L O OU S T . AND GA S C C K L C A P
I
UI S

because the regulator contains a dielectric union as part of the inlet


X P R I DE P OM
PA Y 1 I N
E R W I TH REGU
S E RE AMPE RL Y SERV L AT N Y .
I T UL A IC O .

G V A NO T
G B L EAN I NEXPE E RE R .

2 . VO L Y
F LR A MMEA

E YOUR G REP C A I D
E/ F O R . R

E
G CU
R I G

A H
I V I N JNUYR Y FO C TF OERS M I EN U

assembly. Available in both SAE Flare and F.NPT inlet connection.

DO NSI R .
B Y NQ

AS AT
I T I S S CO A I R L
EU

G
S N C

I TO
S A

P ERSON ANG MPA ,


O I C
L O OU S T . AON K E

P , H E AR HI
U D SC GA S HC
W ICTO KTLHYI SA P E

LA
XP I EP I

IS
M
E E R . D PER W IDTNHT SREGUL P A N 1 RI N

D
D

S
A D J U S TO R
IS

T
S RE AM S A Y .
T UL ARL Y ERV I CE TOR .

S ME
I NG
I

EG E
A D J U S TO ART T E S E S

G U V A NO T
E
A T T EMP S 2 A V O L Y
F R EG I NEXPE R .

TM
O R OR AN

YOUR G RELPPC-A L I D
A G LA S

MP T
R I EG

D
A

GL ACTUOR
H

DO NSI R .
F NEC T OR MA ENC U

AS AT

L L ED /
NY S

PR EM I S A R D I G

/
E R EAM I
ON

I TO
I RN
H TH K E
OU I SC W I T

S E EN / H I S H
Features
IS E

LA
OE E

I S NG
D TS

P ERSON ANGPM

D
.

ST
. R

I T I S S CS
N

S ME
I
EG
E

TM
E
L P - GA S

D
A

UL

T LA O R
• Incorporates integral relief valve.

LV

L L ED /
E D B T OR
A T OR

L NT E C DER
DO E N E R
O

WN N G
50

G TD

OV
5

I V UN

I
O

U
U
3 R E
FO R S
E MU L
(10.691)

P
US

LY O
AL T

T LA O R
L V STE

E D B T OR
S T EC VE

• With 15 PSIG inlet pressure, regulator is designed to not

L NT E C DER
DO E N E R
O
I N OT

WN I N G
L
50

G TD
R TH A

RE
A P WI T I C

E
I

OV
R
5

I V UN
O

U
U
G
D
3 R E
FO R S OR V E R

U
A

pass more than 2 PSIG with the seat disc removed. (10.691)
TO L P

L
E MU L

P
R - GA US

LY O
A L T
45 S S T T EC VE

R
KEEP VENT
0L I N CLEAN
RO T H A

L
SCREEN

RE
A P WI T I C

I S UL

R
VENT

G
TE
D OR V E R
A
TO L P

• Replaceable valve orifice and valve seat disc.


R - GA
MAX INLET
45 S KEEP VENT
10 PSI
0L SCREEN CLEAN

VENT

• Straight line valve closure saves wear on seat disc and


MAX INLET
10 PSI

orifice.

• Built in pressure tap has plugged⅛” F.NPT outlet. Plug


can be removed with a 3⁄16” hex allen wrench.
LV5503BD Series
• Large bonnet vent profile minimizes vent freeze over when
properly installed. 4.08
APPROX
• Extra long lever arm for uniform delivery pressure. 4.08 OUTLET
APPROX INLET
SEE SEE TABLE
• Large diaphragm is extra sensitive to pressure changes. OUTLET
TABLE INLET
SEE
(1.38) SEE TABLE
• Temperature Range: -40°F to +165°F TABLE
(1.38)
(6.120) (3.926) A
(6.120) (3.926)
Materials

25
Body (LV5503BD Series .................................... Die Cast Aluminum

10
Bonnet (LV5503BD Series) ............................... Die Cast Aluminum REGO REGO
Nozzle Orifice ......................................................................... Brass
Spring ...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
YEAR YEAR
Diaphragm ......................... Integrated Fabric and Synthetic Rubber
SILVER SERVICE LIFE WARRANTY

Ordering Information
Inlet Outlet Bonnet Vent Vapor Capacity BTU/hr.
Part Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range Position Propane*
LV5503B4D ½” F. NPT
LV5503B6D ¾” F. NPT 9” to 13” w.c.
¼” 11” w.c. at 10 PSIG Inlet 1,600,000
¾” F. NPT (22.4 to 32.3 Over Inlet
LV5503B16D ½” M. Flare (6.25mm) (27.4 mbar at 0.69 bar) (34 kg/hr)
mbar)
LV5503B56D ⅝” M. Flare
* Maximum flow is based on 10 PSIG (0.69 BARG) inlet and 9” w.c. (22.4 mbar) delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A33
Low Pressure Second Stage Regulators - Special Settings
LV5503H Series

Application
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure,normally 11” w.c. Ideal for larger commercial and
industrial applications, multiple cylinder installations and large
domestic systems.

Features
• Incorporates integral relief valve.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 2 PSIG with the seat disc removed.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure saves wear on seat disc and orifice.

• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug can be


removed with a 3⁄16” hex allen wrench.

• Large bonnet vent profile minimizes vent freeze over when


properly installed.

• Extra long lever arm for uniform delivery pressure.

• Large diaphragm is extra sensitive to pressure changes.

• Temperature Range: -40°F to +165°F LV5503H Series

Materials
Body................................................................... Die Cast Aluminum
Bonnet ............................................................... Die Cast Aluminum
A Nozzle Orifice ......................................................................... Brass
Spring ...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Inlet Outlet Bonnet Vent Vapor Capacity BTU/
Part Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range Position hr Propane*
LV5503H414 ½” F. NPT 7-16 w.c.
14” w.c. @ 10 PSIG Inlet (17.4-39.8
LV5503H614 (34.8 mbar @ 0.69 bar) Inlet
mbar)
LV5503H620 11-28 w.c.
¼” 20” w.c. @10 PSIG Inlet 1,600,000
¾” F. NPT (27.4-69.7
LV5503H620V (6.25mm) (49.8 mbar @ 0.69 bar) Outlet (34 kg/hr)
mbar)
LV5503H640 Inlet
40” w.c. @ 10 PSIG Inlet 28-84 w.c.
LV5503H640V (99.5 mbar @ 0.69 bar) (69.7-209 mbar) Outlet
¾” F. NPT 7-16 w.c.
LV5503H814 14” w.c. @ 10 PSIG Inlet (17.4-39.8
(34.8 mbar @ 0.69 bar) mbar)
9/32” 11-28 w.c. 2,300,000
LV5503H820 1” F. NPT (7.14mm) 20” w.c. @10 PSIG Inlet Inlet
(27.4-69.7 (48 kg/hr)
(49.8 mbar @ 0.69 bar) mbar)

LV5503H840 40” w.c. @ 10 PSIG Inlet 28-84 w.c.


(99.5 mbar @ 0.69 bar) (69.7-209 mbar)
*Maximum flow is based on 10 PSIG (0.69 BARG) inlet 20% drop in delivery pressure

A34 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Second Stage Regulators for 2 PSI Systems
LV4403Y and LV5503Y Series

Application
Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG.
A line pressure regulator is required downstream to reduce the 2
PSIG to a nominal 11” w.c.

Features
• Large vent helps prevent blockage and has ¾” F.NPT for vent piping.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 5 PSIG with the seat disc removed.

• Incorporates an integral relief valve.

• Replaceable valve orifice and valve seat disc.

• Straight line valve closure reduces wear on seat disc.

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.
LV4403Y Series LV5503Y Series
• Large molded diaphragm is extra sensitive to pressure changes.

• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug can be


removed with a 3⁄16” hex allen wrench.

• Select blue finish. LV4403Y4, LV4403Y46R

• Temperature Range: -40°F to +165°F

*Backmount Design
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.
A

Materials
Body (LV4403Y Series)............................................... Die Cast Zinc
Body (LV5503Y Series ...................................... Die Cast Aluminum 2.20 LV5503Y6
Bonnet (LV4403Y Series)............................................ Die Cast Zinc 2.00
Initial Setting
Bonnet (LV5503Y Series) .................................. Die Cast Aluminum 15 PSIG Inlet
Nozzle Orifice ......................................................................... Brass 1.80
5 PSIG Inlet
Spring ...................................................................................... Steel 1.60 10 PSIG Inlet
Valve Seat Disc ..................................................... Resilient Rubber 0 100 200 300 400 500 600 700 800 900 1000 1100 1200
500,000 1,250,000 2,000,000
Diaphragm ......................... Integrated Fabric and Synthetic Rubber

25 10
REGO LV5503Y8
REGO 2.20
Initial Setting
2.00
15 PSIG Inlet
1.80
YEAR YEAR 1.60
5 PSIG Inlet 10 PSIG Inlet
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
SILVER SERVICE LIFE WARRANTY 5,000,000 1,250,000 2,000,000

Ordering Information
Inlet Outlet Bonnet Vent
Part Number Orifice Size Factory Delivery Pressure Adjustment Range Vapor Capacity BTU/hr. Propane**
Connection Connection Position

LV4403Y4 ½” F. NPT ½” F. NPT


LV4403Y66 ¾” F.NPT 1,000,000 BTU/hr
LV4403Y46R* ¼” (21 KG/hr)
½” F. NPT (6.25mm) 2 PSIG @ 10 PSIG
¾” F.NPT Inlet (0.138 bar @ 0.69 1.6-2.2 psig Over Inlet
LV4403Y66R* (0.110-0.151 bar)
¾” F.NPT bar)
LV5503Y6
2,200,000 BTU/hr
LV5503Y8 9/32” (46.42 KG/hr)
¾” F. NPT 1” F. NPT (7.14mm)
* Backmount design
**Maximum flow is based on 10 PSIG (0.69 BARG) inlet pressure and 1.5 PSIG (0.10 BARG) delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A35
Dielectric Second Stage Regulators for 2 PSI Systems
LV4403Y3D Series

Application
Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG.
A line pressure regulator is required downstream to reduce the 2
PSIG to a nominal 11” w.c. (Ø5.250)

RegO Dielectric second stage regulators for 2 PSI systems are


engineered to isolate potential electrical current from metallic piping
Y 46R
before entering a building. The use of a separate dielectric union is 03
Dat
Ou e
t le
# tP
##

4
1-

not necessary because the regulator contains a dielectric union as

LV 4

re 5 P S
##

ss
2.

ur e I
##

Ran
#
ID#

ge
part of the inlet assembly. Available in both SAE Flare and F.NPT inlet
connection.
(8.796)
Features
• F. NPT Dielectric Union is made of Brass
• M. SAE Flare inlet connection made of solid Brass
• Large vent helps prevent blockage and has ¾” F.NPT for vent piping.
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 5 PSIG with the seat disc removed.
• Incorporates an integral relief valve.
(3.898)
• Replaceable valve orifice and valve seat disc.
• Straight line valve closure reduces wear on seat disc.
• Unique bonnet vent profile minimizes vent freeze over when
INLET (1.440)
properly installed.
SEE TABLE
OUTLET
• Large molded diaphragm is extra sensitive to pressure changes. LV4403Y3D
(7.234)
SEE TABLE
• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug can be LV4403Y4D, LV4403Y46RD
removed with a 3⁄16” hex allen wrench.
• Select blue finish.
A
• Temperature Range: -40°F to +165°F

*Backmount Design
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.

Materials
Body............................................................................ Die Cast Zinc

25 10
Bonnet......................................................................... Die Cast Zinc REGO REGO
Nozzle Orifice ......................................................................... Brass
Spring ...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber YEAR YEAR
Dielectric Union Body................................................................ Brass SILVER SERVICE LIFE WARRANTY
Dielectric Union Inlet....................................................... Plated Steel

Ordering Information
Bonnet
Outlet Orifice Vapor Capacity BTU/hr.
Part Number Inlet Connection Factory Delivery Pressure Adjustment Range Vent
Connection Size Propane**
Position
LV4403Y1D ½” M. Flare
LV4403Y3D ⅜” M. Flare ½” F. NPT
LV4403Y5D ⅝” M. Flare
LV4403Y16D
LV4403Y16RD*
½” M. Flare
LV4403Y36D
LV4403Y36RD*
⅜” M. Flare ¾” F. NPT ¼” 2 PSIG @ 10 PSIG Inlet 1.6-2.2 PSIG 1,000,000 BTU/hr (21
Over Inlet
(6.25mm) (0.14 mbar at 0.69 bar) (0.110-0.151 bar) KG/hr)
LV4403Y56D
LV4403Y56RD*
⅝” M. Flare
LV4403Y4D ½” F. NPT ½” F. NPT
LV4403Y66D ¾” F. NPT
LV4403Y46RD ½” F. NPT ¾” F. NPT
LV4403Y66RD ¾” F. NPT*
*Backmount design
**Maximum flow based on 10 PSIG(0.69 bar) inlet and 1.5 PSIG(0.1 bar) delivery pressure

A36 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Dielectric Second Stage Regulators for 2 PSI Systems
LV5503YD Series

Application
Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG.
A line pressure regulator is required downstream to reduce the 2
PSIG to a nominal 11” w.c.
RegO Dielectric second stage regulators for 2 PSI systems are
engineered to isolate potential electrical current from metallic piping
before entering a building. The use of a separate dielectric union is
not necessary because the regulator contains a dielectric union as
part of the inlet assembly. Available in both SAE Flare and F.NPT inlet (Ø7.483)
connection.

Features
• F. NPT Dielectric Union is made of Brass SI
/ FLA
MM A B L E .
V E N J UR Y B Y Q F E
I UI
I
S
L O OU S T . AND GA S C C K L C A P

• M. SAE Flare inlet connection made of solid Brass X P R I DE P OM


E R W I TH REGU PA Y 1 I N
S E RE AMPE RL Y SERV L AT N Y .
I T A I O
F R EGUL N I NEXPE CE R R . .

G V A OT
A T T EMP S 2 A V O L Y
YOUR G REP C A L I D
O R OR A R I EG

E
G CU
H

DO NSI R .
F NEC T OR MA ENC U

AS AT
NY S

I T I S S CO A I R L
PR EM I S A R D I G
• Large vent helps prevent blockage and has ¾” F.NPT for vent piping.
N

I TO
P ERSON ANG MPA ,
O H TH K E
OU I SC W I T

S E EN / H I S H
IS E

LA

I S NG
D TS

D
.

ST
A D J U S TO R
. R

E
N

S ME
I
EG
E
E

TM
E
L P - GA S

D
A

UL
• With 15 PSIG inlet pressure, regulator is designed to not pass

L L ED /
A T OR
more than 5 PSIG with the seat disc removed.

T LA O R
LV

E D B T OR

L NT E C DER
P E V ER
O

WN I N G
50

G TD

E
5

I V UN
• Incorporates an integral relief valve.
O

O
U

DO N
3 R E
FO R S
US
E MU L
(10.691)

LY O
AL T
S T EC VE

R
I N OT

L
R TH A

• Replaceable valve orifice and valve seat disc.

RE
A P WI T I C

I S UL

R
G
TE
D OR V E R
A
TO L P
R - GA
45 S KEEP VENT

• Straight line valve closure reduces wear on seat disc.


0L SCREEN CLEAN

VENT
MAX INLET

• Unique bonnet vent profile minimizes vent freeze over when


10 PSI

properly installed.
LV5503Y6D
• Large molded diaphragm is extra sensitive to pressure changes.
• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug can be
removed with a 3⁄16” hex allen wrench.
• Select blue finish.
• Temperature Range: -40°F to +165°F
4.08
*Backmount Design APPROX
OUTLET INLET
Mounts directly to house line piping. Eliminates need for union joints,
elbows, and mounting brackets. Quick and easy to install.
SEE
TABLE
SEE TABLE A
(1.38)

(6.120) (3.926)

Materials 2.20 LV5503Y6D


Body................................................................... Die Cast Aluminum Initial Setting
Bonnet................................................................ Die Cast Aluminum 2.00
Nozzle Orifice ......................................................................... Brass 15 PSIG Inlet
1.80
Spring ...................................................................................... Steel 5 PSIG Inlet
1.60 10 PSIG Inlet
Valve Seat Disc ..................................................... Resilient Rubber 0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Diaphragm ......................... Integrated Fabric and Synthetic Rubber 500,000 1,250,000 2,000,000
Dielectric Union Body................................................................ Brass
Dielectric Union Inlet....................................................... Plated Steel
LV5503Y8D

25 10
2.20
REGO REGO Initial Setting
2.00
15 PSIG Inlet
1.80
5 PSIG Inlet 10 PSIG Inlet
1.60
YEAR YEAR 0 100 200 300 400 500 600 700 800 900 1000 1100 1200
5,000,000 1,250,000 2,000,000
SILVER SERVICE LIFE WARRANTY

Ordering Information
Inlet Outlet Bonnet Vent Vapor Capacity BTU/hr.
Part Number Orifice Size Factory Delivery Pressure Adjustment Range
Connection Connection Position Propane*

LV5503Y16D ¼”
¾” F.NPT
½” M. Flare (6.25mm)
LV5503Y18D 1” F.NPT
LV5503Y56D 9/32”
¾” F.NPT (7.14mm)
⅝” M. Flare 2 PSIG @ 10 PSIG Inlet 1.6-2.2 psig 2,200,000 BTU/hr
LV5503Y58D 1” F.NPT Over Inlet
(0.138 bar at 0.69 bar) (0.110-0.151 bar) (46.42 KG/hr)
LV5503Y4D ½” F. NPT ¾” F.NPT ¼”
LV5503Y6D ¾” F.NPT (6.25mm)
¾” F. NPT 9/32”
LV5503Y8D 1” F.NPT (7.14mm)
*Maximum flow is based on 10 PSIG (0.69 BARG) inlet pressure and 1.5 PSIG (0.10 BARG) delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A37
Low Pressure Second Stage Tobacco Barn Regulator
LV5503G4 Series

Application
Especially developed for drying barns in the tobacco industry. The
LV5503G4 regulator will supply a steady and constant flow of fuel to
as many as 12 to 20 burners throughout the barn.

Features
• Similar to construction of the LV5503B Series. Provides the
same stability, low lock-up, and sensitive performance.

• Equipped with integral relief valve.

• Built in pressure tap has plugged ⅛” F.NPT outlet. Plug


can be removed with a 3/16” hex allen wrench.

• Distinctive yellow finish.

• Temperature Range: -40°F to +165°F

Materials
Body................................................................... Die Cast Aluminum
Bonnet................................................................ Die Cast Aluminum
Nozzle Orifice ......................................................................... Brass
Spring ...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber

LV5503G4 Series

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Part Inlet Outlet Orifice Bonnet Vent Vapor Capacity BTU/hr.
Number Connection Connection Size Factory Delivery Pressure Adjustment Range Position Propane*

LV5503G4 ¼” 15” w.c. @ 15 PSIG Inlet 8” - 18” w.c. 1,750,000


½” F. NPT ¾” F. NPT Above Inlet
(6.25mm) (37.32mbar @ 1.03 bar) (19.91-44.79 mbar) (36.92 KG/hr)
Maximum flow is based on 15 PSIG (1.03 BARG) inlet pressure and 13” w.c.(32.3 Mbar) delivery pressure.

A38 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Compact Twin Stage Regulators
LV404B4 and LV404B9 Series

Application
This compact two-stage regulator is designed to reduce container
pressure down to 11” w.c. delivery pressure. It is ideal for “on-site”
cylinder applications, mobile homes and average domestic service
including small ASME and 100 to 420 pound DOT cylinders.

Features
• Incorporates integral relief valve.

• With 15 PSIG inlet pressure, regulator is designed to not pass


more than 2 PSIG with the seat disc removed.

• Large vent helps prevent blockage and has ¾” F. NPT for vent
piping.

• Compact size allows for easy installation — especially under


container hoods and within collars.

• Vent on the first stage is consistently in the down position.


LV404B4 LV404B4V9 LV404B9
• Built in pressure taps on both first and second stage regulators
have plugged ⅛” F.NPT outlets. Plugs can be removed with a 3⁄16”
hex allen wrench.

• Select brown finish.

• Temperature Range: -40°F to +165°F

Materials
Body (First Stage)....................................................... Zinc or Brass
Body (Second Stage) ................................................. Die Cast Zinc
Nozzle Orifice ......................................................................... Brass A
Spring ...................................................................................... Steel

25
Valve Seat Disc ..................................................... Resilient Rubber REGO
Diaphragm ......................... Integrated Fabric and Synthetic Rubber

YEAR
SILVER SERVICE LIFE

10
REGO

YEAR
WARRANTY

Ordering Information
Bonnet Bonnet Accessories
Vent Vent Vapor Capacity
Inlet Outlet Orifice Adjustment Position Position BTU/hr 1st Stage Vent
Part Number Connection Connection Size Factory Delivery Pressure Range 1st Stage 2nd Stage Propane* Pipe-Away

LV404B4 Over
Down
½” F. NPT Outlet
LV404B4V9 9 o’clock 9 o’clock
¼” F. NPT
LV404B46 Over
Down
¾” F. NPT Outlet
LV404B46V9 9” to 13” w.c. 9 o’clock 9 o’clock
3/16” 11” w.c. at 100 PSIG Inlet 600,000 BTU/
(22.4 to 32.3 404PE
(4.78mm) (27.4 mbar at 6.9 bar) Over hr (13 KG/hr)
LV404B9 mbar) Down
½” F. NPT Outlet
LV404B9V9 9 o’clock 9 o’clock
F. POL
LV404B96 Over
Down
¾” F. NPT Outlet
LV404B96V9 9 o’clock 9 o’clock
*Maximum flow is based on 25 PSIG (1.72 BARG) inlet pressure and 9” w.c. (22.4 mbar)

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A39
Compact Twin Stage Regulators for LP-Gas
LV404B34 & LV404B39 Series

Application
The compact twin-stage regulator is designed to reduce container
pressure down to 11” w.c. delivery pressure. It is ideal for “on site”
container applications such as homes, mobile homes and cottages
for average domestic service; including small ASME tanks and 100-
420 pound DOT cylinders.

Features
• Large vent helps prevent vent blockage, the second stage
regulator bonnet is tapped for ⅜” F.NPT for vent piping, the high
pressure regulator is tapped with ⅛” F.NPT for vent piping.

• With 15 PSIG inlet pressure, the regulator is designed to not pass


more than 2 PSIG downstream with the seat disc removed.

• Incorporates an integral relief valve on second stage.


LV404B39 LV404B34
• Unique bonnet vent profile minimizes vent freeze over when
properly installed.

• Compact design saves space allows for easy installation –


especially under container hoods with collars. LV404B34

• Built in pressure taps ⅛” F.NPT on both high pressure regulator


inlet and downstream side of the second stage regulator.

• Plugs can be removed with a 3/16” hex Allen wrench.


OUTLET INLET
• Select brown finish. (1/2-14 NPT THD)
(1/4 NPT THD)

• Temperature Range: -40°F to +165°F

A (2.90) (2.51)
Materials
Body First Stage (LV404B39).................................................. Brass
Body First Stage (LV404B34)...................................... Die Cast Zinc
Bonnet Second Stage................................................. Die Cast Zinc LV404B39
Diaphragms........................ Integrated Fabric and Synthetic Rubber
Springs...................................................... Steel and Stainless Steel
Valve Discs............................................. Resilient Synthetic Rubber
LV404B34/B39

13
OUTLET INLET
(CGA 510 POL)
(1/2-14 NPT THD)
12 Inial Seng
Inches of Water Column

11
Delivery Pressure

100 PSIG Inlet

150 PSIG Inlet (2.90) (3.04) (


10

25 10
25 PSIG Inlet REGO REGO
9 50 PSIG Inlet

8
CF/HR 0 50 100 150 200
YEAR YEAR
BTU/HR 125,000 250,000 375,000 500,000 SILVER SERVICE LIFE WARRANTY
Ordering Information
Bonnet Bonnet
Vent Vent
Inlet Outlet Position Position Vapor Capacity
Part Number Connection Connection Orifice Size Factory Delivery Pressure Adjustment Range 1st stage ** 2nd stage** BTU/hr Propane*
LV404B34 ¼” F.NPT
9” to 13” Rear Outlet
LV404B39 F.POL 7/32” 11” w.c. at 100 PSIG Inlet 450,000
½” F.NPT w.c. (22.4 to
LV404B34V9 ¼” F.NPT (5.56mm) (27.4 mbar at 6.9 bar) (9.49 kg/hr)
32.3 mbar) Left 9:00
LV404B39V9 F.POL
*Maximum flow is based on 25 PSIG (1.72 BARG) inlet pressure and 9” w.c. (22.4 mbar)
** Other vent positions available upon request

A40 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Low Pressure Twin Stage Regulators - Special Settings
LV404H Series

Application
This two-stage regulator is designed to reduce container pressure
down to pressure higher than 11” water column. The actual pressure
setting is specified in the table below. These regulators are designed
for installations where the appliances require pressures greater than
11 inches w.c.

Features
• Large vent helps prevent vent blockage, the second stage
regulator bonnet is tapped for ⅜” F.NPT for vent piping, the high
pressure regulator is tapped with ⅛” F.NPT for vent piping.

• With 15 PSIG inlet pressure, the regulator is designed to not pass


more than 2 PSIG downstream with the seat disc removed.

• Incorporates an integral relief valve on second stage.

• Unique bonnet vent profile minimizes vent freeze over when


properly installed.

• Compact design saves space allows for easy installation –


especially under container hoods with collars.

• Built in pressure taps ⅛” F.NPT on both high pressure regulator


inlet and downstream side of the second stage regulator.

• Plugs can be removed with a 3/16” hex Allen wrench.

• Select brown finish.


LV404H
• Temperature Range: -40°F to +165°F

A
Materials
Body First Stage (LV404B39).................................................. Brass
Body First Stage (LV404B34)...................................... Die Cast Zinc
Bonnet Second Stage................................................. Die Cast Zinc
Diaphragms........................ Integrated Fabric and Synthetic Rubber
Springs...................................................... Steel and Stainless Steel
Valve Discs............................................. Resilient Synthetic Rubber

Ordering Information
Bonnet Bonnet Accessories
Inlet Outlet Orifice Factory Delivery Adjustment Vent Vent Vapor Capacity 1st Stage
Part Number
Connection Connection Size Pressure Range Position Position BTU/hr Propane* Vent
1st Stage 2nd Stage Pipe-Away
LV404H415 Rear
15” w.c. @ 100 PSIG Inlet 11(27.4
- 17.5" w.c.
- 43.5 3
LV404H415V3 (37.32mbar @ 1.03 bar) mbar) O’clock
Over
13" - 41" w.c. Outlet
LV404H420 ½” F. NPT 20” w.c. @ 100 PSIG Inlet (32.3-102
(49.8 mbar @ 1.03 bar) Rear
3/16” mbar) 600,000 BTU/hr
¼” F. NPT (13 KG/hr) 404PE
LV404H440 (4.78mm) 30" - 60" w.c.
40” w.c. @ 100 PSIG Inlet (74.6 - 149.3 9
LV404H440V9 (99.5 mbar @ 1.03 bar) 9 O’Clock
mbar) O’Clock
13" - 41" w.c.
LV404H4620 20” w.c. @ 100 PSIG Inlet Over
¾” F. NPT (32.3-102 Rear
(49.8 mbar @ 1.03 bar) Outlet
mbar)
*Maximum flow is based on 25 PSIG (1.72 BARG) inlet 20% drop in delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A41
Twin Stage Automatic Changeover Regulators
7525B Series

Application
These combination automatic changeover, two stage regulators are
especially suitable for homes, mobile homes, cottages, construction
and other portable two cylinder installations. Empty containers may
be replaced without interrupting customer’s gas service.

25
REGO
Features
• Automatic changeover switches from “service” to “reserve”
cylinder automatically without interrupting service. YEAR
SILVER SERVICE LIFE
• The Second Stage Incorporates wide bonnet drip lip vent to guard
against freeze-up when properly installed.

10
REGO
• With 15 PSIG inlet pressure the second stage, regulator
is designed to not pass more than 2 PSIG with the seat disc
removed. YEAR
WARRANTY
• Allows “reserve” cylinder to supplement the flow of gas from the
“service” cylinder during extreme load or severe cold conditions.

• Incorporates molded diaphragm in second stage regulators.

• Integral indicator gauge. 7525B34 7525B4

• Changeover knob and indicator are integral to the first stage.

• Select brown finish on first stage. Materials


Body (First Stage)....................................................... Die Cast Zinc
• Temperature Range: -40°F to +165°F Body (Second Stage) ................................................. Die Cast Zinc
Bonnet First Stage ...................................................... Die Cast Zinc
7525B34 Bonnet, Second Stage ............................................... Die Cast Zinc
First Stage Nozzle Orrifice ..................................................... Brass
A 12.50

12.00
Service Inlet
Pressure
25 PSI
Springs .................................................................................... Steel
50 PSI Valve Seat Discs .................................................... Resilient Rubber
INCHES WATER COLUMN

11.50
DELIVERY PRESSURE

100 PSI
150 PSI
Diaphragms ....................... Integrated Fabric and Synthetic Rubber
11.00

10.50

10.00
Reserve Inlet
9.50
Pressure
9.00 25 PSI
50 PSI
8.50 100 PSI
150 PSI
8.00
CF/HR 0 20 40 60 80 100 120 140 160 180 200
BTU/HR 50,000 150,000 250,000 350,000 450,000
Delivery Pressure Inches Water Column

Service

Ordering Information
Automatic Changeover Vapor Capacity BTU/hr
Inlet Outlet Pigtails Bracket
Regulator Propane*
7525B34 912FA20 400,000
3403-31
7525B34 912FS20 (8.4 KG/hr)
¼” Inverted Flare ½” F. NPT
7525B4 912FA20 450,000
2503-22
7525B4 912FS20 (9.49 kg/hr)
*Maximum flow is based on 25 PSIG (1.72 BARG) inlet pressure and 9” w.c. (22.4 mbar)(22.4 mbar)

A42 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Two PSIG Delivery Pressure Twin-Stage Regulators
LV404Y9 & Compact LV404Y39

Application
SPECIAL 2 PSIG DELIVERY pressure twin stage regulator is
designed to reduce container pressure down to 2 PSIG. A line
pressure regulator is required downstream to reduce the 2 PSIG to a
nominal 11” w.c.

Features
• Incorporates an integral relief valve in the 2 PSIG stage portion of
the regulator.

• Designed to pass no more than 5 PSIG with the seat disc


removed.

• Large vent helps prevent blockage and is tapped with a FNPT


thread for piping away.

• Compact Design

• Built in pressure taps. Plugs can be removed with a 3/16” hex


allen wrench.

• Select Blue Finish to designate 2 PSIG delivery pressure for 2-


pound systems.
LV404Y39 LV404Y9
• Temperature Range: -40°F to +165°F

Materials
Body (First Stage)................................................................... Brass
Body (2 PSIG Stage) .................................................. Die Cast Zinc 363/64”
Bonnet, Second Stage ............................................... Die Cast Zinc
363/64”
Diaphragms ....................... Integrated Fabric and Synthetic Rubber CON T
R OL S I N T L .
E NG I NE E R E D

Springs ..................................................... Steel and Stainless Steel VE N T O


PE
P R OT E N ING L P- G
A
SE EN S I S

Valve Discs ............................................................ Resilient Rubber


CTI

A
/
:2 : C H EA H I
IN S V E C VE R
T T AL R GH
R EGU L FI R D
R EG AL LE O V E I
CA OR R A

UL D
ATO U R L A
I T I S ATOR E
LL

LY ID

.
Y WI T H

VO PT. YOUR I N E X P E R I E N C L AR O R A

OR M D A N G E IN
R
ND B E

FOR OU
DE S IS T F O R A NTS WI TH E D P E Y

E X ER IO C O. DO NOT AT T K LY : AP
DO

TDO
R

E
TO

OR AK R O
PL

E
WN

S
&
U S JUS T

OS S I N JU R Y B Y Q I F E
U

AD
SE

GA GAS C O. R E G MPT : E V I N

WA R N I N G

LV404Y39
I VE /
SCREEN CLEAN

U
S
4403
KEEP VENT

ME
N

F L AMMAB L
VENT

HTE N
LV

2.4
IG

TH I R S
T

E
U

U IC
S

E
Delivery Pressure PSIG

.
R

EG
N ULA
L
O

S E T O T OR .
U
1
SC

E P RV

2.2
DI S
L
L

R CO
A IC
RE

TE CU IR E RE N N E C T
IS U

LA D
AT OR
G

GUL ATO G
R
GA I NG TAMPE R
TO LP
- G P WITH
R
S
AS I S RE MIS E S
45 0 S ME
L LLED/

2 E L ON
N OR
E GE
I NA

150 PSIG
1.8
45/64”
1.6

1.4 75 PSIG 100 PSIG


25 PSIG 45/64” B
1.2
Flow CFH 0 100 200 300 400 500
BTU/HR 500,000 750,000 1,00,000
250,000 B
515/16”
Delivery Pressure PSIG

515/16”

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Bonnet
Bonnet Vent
Outlet Adjustment Vent
Part Number Inlet Connection Orifice Size Factory Delivery Pressure Position Vapor Capacity BTU/hr Propane*
Connection Range Position
2nd Stage
1st Stage

LV404Y39 Outlet 600,000 BTU/hr


LV404Y39V9 2 PSIG @ 100 PSIG 1.8-2.5 PSIG 9 o'clock (12.66 KG/hr)
F.POL ½” 7/32” Inlet (0.12-0.17 Down
LV404Y9 (CGA 510) F.NPT (5.56mm) Outlet
(0.14 bar at 6.9 bar) bar) 800,000
LV404Y9V9 9 o'clock (16.88 KG/hr)
*Maximum flow is based on 25 PSIG (1.72 BARG) inlet pressure and 1.5 PSIG (0.10 BARG) delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A43
Two Stage Regulator Outfits
5807, 5808, 5820 Series

25
Application REGO
These outfits contain the equipment required to provide two-stage
regulation.
YEAR

Features SILVER SERVICE LIFE


• Includes a new pigtail. This helps ensure that a new pigtail is

10
installed along with the regulator. REGO
• Features, designs, and performance characteristics of the
individual components may be found under the appropriate
section of this catalog. YEAR
WARRANTY
Ordering Information LV4403TR9 LV4403B Series
1st Stage Regulator Included 2nd Stage Regulator Included
Kit Inlet x Outlet Inlet x Outlet Bracket Pigtail Vapor Capacity
Number Part Number Female Part Number F. NPT Included Included BTU/hr Propane*
913PS12
5807 F.POL x ½” LV4403B4 ½” x ½” 2503-22
LV4403TR9
5808 NPT LV4403B46R ½” x ¾”
913PS12 935,000 BTU/hr
Not (20 KG/hr)
LV4403TR96 F.POL
5820 x ¾” LV4403B66R Required
¾” x ¾”
NPT 2503-22

Twin Stage Regulator Outfits 5828 and 5832

25
REGO
Application
This outfit contains the equipment required to provide twin-stage regulation.
YEAR
Features SILVER SERVICE LIFE
• Includes a new pigtail. This helps ensure that a new pigtail is installed

10
along with the regulator. REGO

A • Features, designs, and performance characteristics of the individual


components may be found under the appropriate section of this catalog.
YEAR
WARRANTY LV404B4 LV404B34
Ordering Information
Twin Stage Regulator Vapor Capacity
Kit Number Included Inlet Outlet F. NPT Pigtails Included BTU/hr Propane*
5828 912JS12
LV404B4 ¼” F.NPT 600,000 912JS Series
5829 912JS20 (12.66 KG/hr)
5839 LV404B9V9 F. POL ½” 912PS12
5832 912JS12
LV404B34V9 ¼” F.NPT 450,000
5833 912JS20 (9.49 kg/hr)

Automatic Changeover Regulator Outfits 5726B34, 5727B34, 5754B4, 5755B4


Application
This outfit contains the equipment required to provide twin-stage

25 10
regulation. REGO REGO

Features
• Includes 2 new pigtails. This helps ensure that a new pigtail is YEAR YEAR
installed along with the regulator. SILVER SERVICE LIFE WARRANTY

• Features, designs, and performance characteristics of the


individual components may be found under the appropriate
section of this catalog.
Ordering Information 912FA20 7525B4

Automatic
Kit Outlet F. Pigtails Bracket Vapor Capacity BTU/hr
Changeover Inlet
Number NPT Included-2 Included Propane*
Regulator Included
5726B34 7525B34 912FA20 400,000 BTU/hr
3403-31
5727B34 7525B34 ¼” 912FS20 (8.4 KG/hr)
Inverted ½”
5754B4 7525B4 Flare 912FA20 450,000
2503-22
5755B4 7525B4 912FS20 (9.49 kg/hr)

A44 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Compact Regulators
302 Series

Application
These compact regulators are designed for smaller outdoor grills
and fish cookers. It is intended for use on small portable appliances
that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe
systems per NFPA 58, 2020 edition.

Features
• All metal, die cast construction.

• Molded diaphragms ensure close control of burner pressure.

• Durable valve levers.

• Variety of model configurations and sizes available.

• All POL inlet connections are soft nose.

• Temperature Range: -40°F to +165°F

Materials 302
Body............................................................................ Die Cast Zinc
Bonnet ........................................................................ Die Cast Zinc
Springs .................................................................................... Steel
Valve Seat Discs .................................................... Resilient Rubber
Diaphragms ............................................. Molded Synthetic Rubber

25 10
REGO REGO

YEAR YEAR
SILVER SERVICE LIFE WARRANTY 302V

Ordering Information
Part Inlet Outlet Bonnet Vent Vapor Capacity
Type Orifice Size Factory Delivery Pressure Adjustment Range
Number Connection Connection Position BTU/hr. Propane*

302 Small Vent


¼” F. NPT Above Inlet

302V Drip Lip


Single ¼” F. NPT 3/8” F. #50 Drill 11” w.c. at 100 PSIG Inlet 9” to 13” w.c. 125,000 BTU/hr
Above Inlet
Stage NPT (1.77mm) (27.4 mbar at 6.9 bar) (22.4 to 32.3 mbar) (2.6 KG/hr)
302V9 ¼” F. NPT
Drip Lip at
302V9LS Soft POL 9 o’clock
w/o orifice
Maximum flow is based on 25 PSIG (1.72 BARG) inlet pressure and 9” w.c. delivery pressure.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A45
High Pressure Industrial / Commercial Pounds-to-Pounds Regulators
597F Series

Application
Designed to reduce propane gas container pressure down to between
3 and 100 PSIG. Ideal for liquid or vapor service, they can be used
in a variety of applications including salamander heaters, weed
burning torches, fish cookers, tar pot heaters, and other industrial
type services.

Features
• Provides high capacity performance at a reasonable price.

• Suitable for both liquid and vapor service.

• Compact design provides for easy installation.

• Negative or indirect acting design provides for excellent


performance when needed most – in cold weather, when tank
pressures are lowest and system demands are highest.

• Consistent delivery pressure, especially in cold weather, helps


ensure maximum performance from the second stage regulator.
597F
• Can be readily fitted with a pressure gauge in the ¼” F.NPT port.

• Molded diaphragm provides an o-ring like seal between the body


and the bonnet.

• Fully painted in brilliant red for complete corrosion protection.


Materials
• Available in four adjustable ranges for maximum performance. Body........................................................................................... Zinc
Bonnet ....................................................................................... Zinc
• Bonnet and body are assembled in the USA using the unique, Springs .................................................................................... Steel
patented RegULok™ Seal System. Valve Seat Discs .................................................... Resilient Rubber
A • Temperature Range: -40°F to +165°F
Diaphragms ....................... Integrated Fabric and Synthetic Rubber
Adjusting Screw....................................................................... Brass

25
REGO

YEAR
SILVER SERVICE LIFE

10
REGO

YEAR
WARRANTY

Ordering Information
Part Capacity Determined Vapor Capacity BTU/hr
Adjustment Method Inlet Connection Outlet Connection Adjustment Range
Number at Set Pressure of PSIG* Propane**
1 to 15 PSIG 10 PSIG 1,750,000 BTU/hr (37
597FA
(0.07 to 1.0 bar) (0.7 bar) KG.hr)
10 to 30 PSIG 20 PSIG 3,000,000 BTU/hr (63
597FB
(0.69 to 2.0 bar) (1.4 bar) KG/hr)
Tee Handle ¼” NPT ¼” NPT
20 to 45 PSIG 30 PSIG 3,500,000 BTU/hr (74
597FC
(1.4 to 3.1 bar) (2.0 bar) KG/hr)
40 to 100 PSIG 40 PSIG 4,500,000 BTU/hr (95
597FD
(2.75 to 6.9 bar) (2.75 bar) KG/hr)
* Set pressure established at 100 PSIG(6.9 BARG) inlet and a flow of 250,000 BTU/hr.
** Capacity determined at actual delivery pressure 20% less than set pressure with inlet pressure 20 PSIG higher than the set pressure.
NOTE: Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. Use of a relief valve upstream or downstream of these regulators
is recommended in accordance with NFPA 58.

A46 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
High Pressure Industrial / Commercial Pounds-to-Pounds Regulators
1580V™ and AA1580V™ Series

Application
Designed to reduce LP-Gas and anhydrous ammonia container
pressures to between 3 and 125 PSIG. Precision-built with a multi-
million BTU capacity, the 1580V™ series is perfect for such big,
tough jobs as crop dryers, asphalt batch mixing plants, road building
“tar wagons”, heat treating and other large industrial and commercial
loads. It’s also ideal as a first stage regulator in large multiple
operations. The AA1580V™ series is ideal for use in anhydrous
ammonia applications such as blue print machines and heat treating.

Features
• Large nozzle and straight through flow provides high capacity and
resistance to freeze-up.

• O-ring on retainer assembly provides a dampening effect to


reduce vibration.

• Suitable for both liquid and vapor service.

• Can be readily fitted with pressure gauge in ¼” F. NPT port.

• Temperature Range: -40°F to +165°F

Materials
Body..................................................................... Forged Aluminum
Bonnet ............................................................... Die Cast Aluminum
Spring ...................................................................................... Steel
Valve Seat Discs .................................................... Resilient Rubber
Diaphragms ....................... Integrated Fabric and Synthetic Rubber

25 10
REGO REGO 1580V™

YEAR YEAR
SILVER SERVICE LIFE WARRANTY

Ordering Information
Capacity
Part Adjustment Inlet & Outlet Recommended Delivery Determined at Set Vapor Capacity BTU/hr
Number Service Method Connections Pressure Range (PSIG) A Width B Height (max.) Pressure of PSIG* Propane**
3 to 30 PSIG 20 PSIG 7,000,000 BTU/hr
1584VN (0.2 to 2.0 bar) (1.4 bar) (148 KG/hr)
½” 25 to 50 PSIG 30 PSIG 7,500,000 BTU/hr
1584VL LP-Gas 215/16” 4⅞”
F. NPT (1.7 to 3.4 bar) (2.0 bar) (158 KG/hr)
45 to 125 PSIG 60 PSIG 8,000,000 BTU/hr
1584VH (3.1 to 8.6 bar) (4.1 bar) (169 KG/hr)
3 to 30 PSIG 20 PSIG 11,000,000 BTU/hr
1586VN (0.2 to 2.0 bar) (1.4 bar) (232 KG/hr)
Tee ¾” 25 to 50 PSIG 30 PSIG 12,000,000 BTU/hr
1586VL LP-Gas Handle F. NPT (1.7 to 3.4 bar) (2.0 bar) (253 KG/hr)
45 to 125 PSIG 60 PSIG 14,000,000 BTU/hr
1586VH (3.1 to 8.6 bar) (4.1 bar) (295 KG/hr)
3 ½” 7”
3 to 30 PSIG 20 PSIG 11,000,000 BTU/hr
1588VN (0.2 to 2.0 bar) (1.4 bar) (232 KG/hr)
1” 25 to 50 PSIG 30 PSIG 12,000,000 BTU/hr
1588VL LP-Gas F. NPT (1.7 to 3.4 bar) (2.0 bar) (253 KG/hr)
45 to 125 PSIG 60 PSIG 14,000,000 BTU/hr
1588VH (3.1 to 8.6 bar) (4.1 bar) (295 KG/hr)
*Set pressure is established with 100 PSIG(6.9 BARG) inlet pressure and a flow of 500,000 BTU/hr.
**Capacity determined at 100 PSIG inlet, set pressure noted on chart at 20% drop.

NOTE: Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. Use of a relief valve
upstream or downstream of these regulators is recommended in accordance with NFPA 58.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A47
High Pressure Industrial / Commercial Pounds-to-Pounds Regulators
1580V™, X1580V™ and AA1580V™ Series

1584™/X1584VN™
1586™/X1586™/1588VN™
Set Point 100 PSIG Inlet, 10 PSIG Outlet, 200 SCFH Flow
Set Point 100 PSIG Inlet, 10 PSIG Outlet, 200 SCFH Flow
17 13
12 25 PSIG Inlet
15
50 PSIG Inlet 100 PSIG Inlet
11
Inial Seng 25 PSIG Inlet 120 PSIG Inlet
13 Set Point
100 PSIG Inlet 10 150 PSIG Inlet
11 50 PSIG Inlet 120 PSIG Inlet 175 PSIG Inlet
150 PSIG Inlet 9
PSIG

PSIG
9 175 PSIG Inlet 8
7
7
6
5
10 PSIG Inlet 5
10 PSIG Inlet
3 4
SCFH 0 500 1000 1500 2000 2500 3000 3500 4000 SCFH 0 500 1000 1500 2000 2500 3000 3500
BTU/HR 1,250,000 2,500,000 3,750,0000 5,000,000 6,250,000 7,500,000 8,750,000
BTU/HR 1,125,000 2,500,000 3,750,000 5,000,000 6,250,000 7,500,000

1584™/X1584VL™ 1586™/X1586™/1588VL™
Set Point 100 PSIG Inlet, 30 PSIG Outlet, 200 SCFH Flow Set point 100 PSIG inlet, 30 PSIG outlet 200 SCFH
34
34
32 32
Set Point 100 PSIG Inlet
Inial Seng 50 PSIG Inlet 30 50 PSIG Inlet
30 120 PSIG Inlet
100 PSIG Inlet
120 PSIG Inlet 28
28
PSIG
PSIG

150 PSIG Inlet 26


175 PSIG Inlet
A
26
24
24 22

22 20
SCFH 0 1000 2000 3000 4000 5000 6000
20 BTU/HR 2,500,000 5,000,000 7,500,000 10,000,000 12,500,000 15,000,000
SCFH 0 1000 2000 3000 4000 5000 6000
BTU /HR 2,500,000 5,000,000 7,500,000 10,000,000 12,500,000 15,000,000

1584™/X1584VH™ 1586™/X1586™/1588VH™

63
Set Point 100 PSIG Inlet, 60 PSIG Outlet, 200 SCFH Flow
Set point 100 PSIG Inlet, 60 PSIG outlet, 200 SCFH Flow
61 Inial Seng
60 Set Point 100 PSIG Inlet
59
120 PSIG Inlet
57 100 PSIG Inlet 55 150 PSIG Inlet
120 PSIG Inlet 175 PSIG Inlet
55
PSIG
PSIG

150 PSIG Inlet


53 50 60 PSIG Inlet
175 PSIG Inlet
51
45
49 60 PSIG Inlet
47 40
SCFH 0 1000 2000 3000 4000 5000 6000
45
BTU/HR 2,500,000 5,000,000 7,500,000 10,000,000 12,500,000 15,000,000
SCFH 0 1000 2000 3000 4000 5000 6000
BTU /HR 2,500,000 5,000,000 7,500,000 10,000,000 12,500,000 15,000,000

1584, X1584VN, 1586, X1586, 1588VN, X1584VL, 1586, X1586, 1588VL, X1584VH, X1586 and 1588VH are Trademarks of ECI LLC.

A48 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
High Pressure / High Temperature Industrial / Commercial
Pounds-to-Pounds Regulators X1584V™, X1586V™, and X1588V™ Series

Application
Designed to reduce LP-Gas container pressures to between 3 and
50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing
and other large industrial and commercial load application utilizing
high temperature LP-Gas or high temperature atmosphere under
conditions up to 300ºF. Also ideal as a first stage regulator in large
multiple operations.

Features
• Special diaphragm and seat materials are suitable for up to 300ºF.
temperatures.

• Large nozzle and straight through flow provides high capacity and
resistance to freeze ups.

• Suitable for both liquid and vapor service.

• Can be fitted with high pressure gauge in ¼” F. NPT port. RegO


recommends that these gauges use silver braze rather than soft X1584™
solder construction.

25 10
• Temperature Range: -40°F to +300°F REGO REGO

Materials YEAR
Body..................................................................... Forged Aluminum YEAR
Bonnet ............................................................... Die Cast Aluminum SILVER SERVICE LIFE WARRANTY
Spring ........................................................................ Stainless Steel
Diaphragms ....................... Integrated Fabric and Synthetic Rubber
Seat Discs ....................... High Temperature Resilient Composition
Backup Seal .................... High Temperature Resilient Composition

A
Ordering Information
Capacity
Adjustment Inlet & Outlet
Part Number Service Width Height Adjustment Range Determined at Set Vapor Capacity BTU/hr
Method Connections
Pressure of PSIG* Propane**

X1584VN 3 to 30 PSIG 20 PSIG 7,000,000 BTU/hr


(0.2 to 2.0 bar) (1.37 bar) (148 KG/hr)
X1584VL 2⅞” 8⅞” ½” F. NPT
25 to 50 PSIG 30 PSIG 7,500,000 BTU/hr
(1.7 to 3.4 bar) (2.06 bar) (158 KG/hr)
X1584VH 45 to 125 PSIG 60 PSIG 8,000,000 BTU/hr
(3.1 to 8.6 bar) (4.1 bar) (169 KG/hr)
X1586VN 3 to 30 PSIG 20 PSIG 11,000,000 BTU/hr
(0.2 to 2.0 bar) (1.37 bar) (232 KG/hr)
X1586VL LP-Gas Tee Handle ¾” F. NPT
25 to 50 PSIG 30 PSIG 12,000,000 BTU/hr
(1.7 to 3.4 bar) (2.06 bar) (253 KG/hr)
X1586VH 45 to 125 PSIG 60 PSIG 14,000,000 BTU/hr
(3.1 to 8.6 bar) (4.1 bar) (295 KG/hr)
35/16” 6⅞”
X1588VN 3 to 30 PSIG 20 PSIG 11,000,000 BTU/hr
(0.2 to 2.0 bar) (1.37 bar) (232 KG/hr)
X1588VL 25 to 50 PSIG 30 PSIG 12,000,000 BTU/hr
1” F. NPT (1.7 to 3.4 bar) (2.06 bar) (253 KG/hr)
X1588VH 45 to 125 PSIG 60 PSIG 14,000,000 BTU/hr
(3.1 to 8.6 bar) (4.1 bar) (295 KG/hr)
* Set pressure is established with 100 PSIG (6.89 BARG) inlet pressure and a flow of 500,000 BTU/hr. propane.
** Capacity determined at 100 PSIG (6.89 BARG) inlet, set pressure noted on chart at 20% drop.
NOTE: Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. Use of a relief valve
upstream or downstream of these regulators is recommended in accordance with NFPA 58.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A49
Vapor Relief Valves 3139 Series

Application
Designed for use as a relief valve on high pressure regulators to
comply with NFPA 58 2020 5.10.1.10 “High-pressure regulators with
a rated capacity of more than 500,000 BTU/hr where permitted to be
used on two stage systems shall incorporate an integral relief valve or
shall have a separate relief valve.”

Features
• Pop-action design keeps product loss to a minimum.
3139-18 3139-26 3139-38

25 10
• Suitable for use downstream of 1580™ series regulators on vapor REGO
systems to comply with NFPA 58 requirements. REGO

• Install a tee downstream from the regulator outlet to ensure


maximum flow from the relief valve.
YEAR YEAR
• Brass body and seat disc assembly.
SILVER SERVICE LIFE WARRANTY
• Temperature Range: -40°F to +165°F

Ordering Information
Connection Flow Capacity at 120% of Set
Part Number Set Pressure Set Pressure Regulator Settings Height Width Pipe Away Adapter
Size Pressure (SCFH Propane)
3139-18 18 PSIG 1.24 BARG 10 PSIG (0.69 bar) 1357*
3139-26 ¼” M. 27/32”
26 PSIG 1.79 BARG 15 PSIG (1.03 bar) NPT 2 1 1/16” 1725** B-009412-2B
3139-38 38 PSIG 2.62 BARG 20 PSIG (1.38 bar) 2304***
* Flow recorded at 21.6 PSIG (1.49 BARG) inlet pressure for this valve.
** Flow recorded at 31.2 PSIG (2.15 BARG) inlet pressure for this valve.
*** Flow recorded at 45.6 PSIG (3.14) inlet pressure for this valve.

Brackets
A
RegO Brackets are especially designed for use in installing RegO
Regulators in applications requiring the use of a bracket.

Part
Number Material For Use With Regulator Model:
3403-31* Cadmium LV3403, LV404B34, LV404B39, LV404Y39
2503-22 Plated Steel
LV404B4 LV404B9, LV404Y9 Series,LV5503
2503-19 Aluminum Series LV4403 Series
2503-19 2503-22 3403-31
* Includes two screws for installation into the regulator body.

A50 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
POL Adapters

Male POL Swivel Adapters

10
REGO

YEAR
(CGA 510) POL WARRANTY
970 (CGA 510) POL
970S
Hard Nose POL
Soft Nose POL w/60 DMS Orifice

D
D

C B B
C
50-70
Micron
A Filter
(CGA 510) POL A
970AXS
Soft Nose POL w/Excess Flow 3199W (CGA 510) POL
Heavy Duty Hard Nose POL w/Excess Flow
3188 Series
D

C B

970AX (CGA 510) POL


Hard Nose POL w/Excess Flow 970AW 970JR
970HT Hard Nose POL w/Hose Barb Connection
Soft Nose POL w/Handwheel
Ordering Information
Part A B C D Vapor at 100 PSIG Liquid
Number Material Outlet Thread Hex Drill Overall Length Inlet (SCFH) (GPM)
970 ¼”
970S .040” orifice - -
970AS 0.188” orifice
215⁄32”
970AX ⅞”
¼”
970AXS ⅛” 404 1.10
M. NPT
970WXS
3199W 5⁄32” 27⁄16” 575 0.95
Brass
970AW 3⁄16”
1⅜” 215⁄32”
970HT .040” orifice - -
970JR ¼” ⅞” 5⁄32” 2⅝”
Hose Barb
3188A 350 .95
3188B ½” 1⅛” 9⁄32” 2½” 700 1.9
M. NPT
3188C 1180 2.9
Note: All nipples incorporate wrench hex section.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A51
POL Adapters

B B

10
REGO

D A C D C

YEAR
(CGA 510) POL WARRANTY
(CGA 510) POL A
Male POL x Female NPT Male POL x Male NPT and SAE Flare
Ordering Information
Part A B C D
Ordering Information Number Material Hex Diameter
Part A B C D ⅜”
Number Material F.NPT Hex Diameter 2906D 25⁄64” ⁄ ”
11 32
M. NPT
2906A ¼” 1 ⁄ ”
11 32 ⅞” ⅜”
Brass ⁄ ”
9 32
2906F Brass 23⁄32” ⅞”
2906G ½” 2” 1⅛” SAE Flare
⁄ ”
9 32
½”
2906E 29⁄32”
SAE Flare
B
B

CGA 510 D
A C
(POL) CGA 510 D Female POL x Male NPT
(POL) A C

Female POL x Female NPT and Female POL

Ordering Information
Ordering Information
A B C D
Part A B C D Part Number Material Hex Diameter
Number Material Hex Diameter
5761A ¼” M.NPT ⁄ ”
A
3 16

5760A ¼” F.NPT 5761B ⅜” M.NPT 13 32⁄ ”


⁄ ”
13 32
Brass 1⅝” 1⅛”
5760B ⅜” F.NPT 1⅝” 1⅛” 5761C ½” M.NPT
5760C Brass ½” F.NPT ⁄ ”
7 16
7 16⁄ ”
5761D ¾” M.NPT
5760D ¾” F.NPT 1⅞” 1⅜”
⁄ ”
13 32
5760S POL (CGA 510) 2⅛” 1⅛”

1¼” B
⁄”
78

Hose
Adapter Ordering Information
For use with fuel Part A B
gases (LP-Gas, ¼” Min ⁄ ” Hex.
9 16
Number Material
5⁄8”

Acetylene). Hex.
¼” Female
15774-1 Brass ¼” M. NPT Inverted
A B Flare
A
B Female Inverted Flare
Ordering Information
x Male NPT
Part A B
Number Material D
1300 Brass 9
”-18UNF (L.H.)
16 ¼” M. NPT

C
23⁄16”
B A E

Pressure
Gauge Adapter
A
1¼”
Hex.
F
C
Ordering Information
Ordering Information Part
Part Number Material A B C D E F
Number Material A B C 1328 ⅜” SAE Male Flare ⅜” SAE Female Flare ⁄ ”
13 16 2” 1⅛”
⅜”
1494-1 Brass ½” F. NPT ¼” F. NPT ½” M. NPT 1331 Brass ½” SAE Male Flare ½” SAE Female Flare Hose 1’ 2⅛”
Barb 1¼”
1332 ⅝” SAE Male Flare ⅝” SAE Female Flare 1⅛” 2½”

A52 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Copper Pigtails 912 and 913 Series

Pigtails are available in a variety of connections, sizes and styles.


Care should always be taken in selecting the proper pigtail for a
particular application.

Note: RegO recommends a new pigtail be installed with every new D912
and replaced regulator.

913PS12 Dielectric Pigtails Ordering Information


Part Number
Straight Pigtails Ordering Information ¼” Tube ⅜” Tube
Part Number Approximate ⅞” Hex Short ⅞” Hex Short
¼” Tube ⅜” Tube Connections Length Nipple Nipple
12” D912P12 D913P12
Approximate ⅞” Hex Short 1⅛” Hex Long ⅞” Hex
20” D912P20 D913P20
Connections Length Nipple Nipple Short Nipple
M.POL x M.POL 30” D912P30 D913P30
5” 913PS05 36” D913P36
8" - 913PS08 -
- 48” D913P48
10" 913PS10 12” D912J12
12” 912PS12 913PS12 ¼” M.NPT x
M.POL x 20” D912J20 -
20” 912PS20 912PA20 913PS20 M.POL
M.POL 30" D912J30
30” 912PS30 912PA30 913PS30
36” 912PS36 912PA36 913PS36
48” 912PS48 912PA48 913PS48
60" 912PS60 912PA60
12” 912FS12
-
15" 912FS15
¼” Inverted 20” 912FS20 912FA20
-
Flare x 30” 912FS30 912FA30
M.POL 36” 912FS36 912FA36
40" 912FS40
48" 912FS48
-
912FA48 A
5” - 913JS05
12” 912JS12
-
913JS12 Presto-Tap® Pigtails Ordering Information
¼” M.NPT x
20” 912JS20 912JA20 913JS20 Part Number
M.POL
30" 912JS30 913JS30
36” 912JS36 - ¼” Tube ⅜” Tube
½” M.NPT x Approximate ⅞” Hex Short ⅞” Hex Short
12” - 913LS12
M.POL Connections Length Nipple Nipple
-
½” M.NPT x 12” PT912PS12 PT913PS12
12” 913KL12
⅜” M.NPT
M.POL x M.POL 20” PT912PS20
48” PT912PS48
-
¼” Inverted Flare
20” PT912FS20
x M.POL
¼” M.NPT x 12” PT912JS12 PT913JS12
M.POL 20” PT912JS20 -

Features
913PS12G 913PS12H • Heavy duty construction.
• Individually soldered connections to the copper tubing.
• Each pigtail is individually tested prior to shipment.
Bent Pigtails Ordering Information • Temperature Range: -40°F to +165°F

Part Number
⅜” Tube
Materials
Approximate Type/Degree of Tubing..................................................................................... Copper
Connections Length ⅞” Hex Short Nipple Bend Connection .............................................................................. Brass
¼” M. NPT x
913JS05A
M. POL 5” 90°
913PS05A
M. POL x
913PS12G 270° Right Hand
M. POL 12”
913PS12H 270° Left Hand

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A53
Accessories

Tee Check Manifolds


1350R and 1450R
For use in systems that require uninterrupted gas service during
cylinder exchange. Especially for summer cottages, mobile homes
and single appliance loads.
• Temperature Range: -40°F to +165°F

Part Number Inlet Connections Outlet Connection


1350R 1450R
1350R F. POL M. POL

1450R ¼” Inverted Flare ¼” M. NPT

Multiple Cylinder Manifolds


1350E and 1450E
Use with suitable pigtails to connect multiple cylinders together. Ideal
for loads that require more than one cylinder to be in service at a time. 1450E 1350E
• Temperature Range: -40°F to +165°F

Part Number Inlet Connections Outlet Connection


1350E F. POL M. POL
1450E ¼” Inverted Flare ¼” M. NPT

Adjustable Flexible Vent Kit


Application
The LV960 Series Adjustable vent kit is designed to assist in meeting
the point of discharge requirements for regulators in NFPA 58; it does
A this by diverting the LP-Gas vapor away from sources of ignition,
openings to into direct vent appliances or mechanical air intakes. The
Adjustable Vent Kit is supplied with two reusable end fittings installed
on the flexible tubing, mounting bracket with self-tapping screw, 90
degree vent elbow and installation instructions.

Flex Tubing Reusable End Mounting LV960


Part Number Length Connectors 90° Elbow Bracket 4403-30
LV960-48 48” (4 feet) 3
Replacement Vent Screens
LV960-72 72” (6 feet) 2 4
Part Number Regulator Outlet Connection
1
LV960-120 120” (10 feet) 5
4403-30 ¾" F. NPT
LV960-80* NA NA NA
2302-43 ⅜” F. NPT
*90° Elbow only

Test Kits
Low Pressure Test Set Water Manometer Kit
2434A Series 1212 Kit
This kit provides the equipment necessary for checking regulator The water manometer kit is especially suited for use with low
delivery pressure (low pressure) at the appliances. The basic set pressure LP-Gas systems. It is ideal for pressure checks downstream
contains a 2424A-2 low pressure gauge and a 3 foot — 3⁄16” O.D. of the low pressure regulator and at the appliances.
flexible synthetic rubber tube. Adapters are also available.
Part Number Contents Adapters Adapter size Part
Number Description
1328 ⅜“ OD
2434A 1331 1212 KIT Flexible Tube Water Manometer Kit
Test Kit ½“ OD
1332 ⅝“ OD

2434A 1328 Adapter


1212 KIT
A54 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Accessories

High Pressure Gauge Adapter


2962
Designed for testing high pressure lines. Adapter has 0 to 300 PSIG
(0 to 20.68 BARG) gauge. A bleeder valve allows you to bleed down
to correct pressure during pressure tests.
• Temperature Range: -40°F to +165°F

Part Inlet Outlet Pressure Gauge Pressure Gauge


Number Connection Connection Range (PSIG) Range (BARG)
Soft Nose
2962 F. POL 0 - 300 0 - 20.68
M. POL

2962

Adhesive Warning Labels DANGER WARNING


These adhesive warning labels are intended for application as close LP-GAS IS EXTREMELY
as possible to the LP-Gas regulator once the regulator has been
installed.
FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL,
A
OR HEAR ESCAPING GAS... EVACUATE AREA IMMEDIATELY! CALL YOUR
LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT
STORE IN BUILDING OR ENCLOSED AREA. DO NOT USE ON HOT AIR
BALLOONS OR AIRCRAFT.
Insist that your LP-Gas dealer regularly inspect and maintain this installation and
Part properly instruct you in safety matters.
Number Description
Make sure ice, snow drifts, dirt, bugs and other foreign material do not obstruct
LV4403-400 Adhesive Warning Label vent passage-ways and openings. The vent opening must have a screen
installed. If screen is missing, call your gas dealer for immediate examination and
replacement.
DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL.
DO NOT FILL CONTAINER UNLESS THIS LABEL IS READABLE.
ADDITIONAL SAFETY INFORMATION IS AVAILABLE FROM

Engineer ed Contr ol s Printed in U.S.A. 04-0994-1189


® International, Inc. Part Number LV4403-400

DANGER READ THIS FIRST


WARNING 100 RegO Drive PO Box 247 Elon College, NC 27244 USA Phone (336) 449-7707 Fax (336) 449-6594 www .regoproducts.c om

LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE


AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR LV4403-400
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Make sure you are thoroughly trained before you attempt any regulator installation or maintenance. Improper
conditions or procedures can cause accidents resulting in property damage and personal injury.
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &
Maintenance” and RegO Safety Warning “LP-Gas Regulators” found in the regulator section of the L-500 & L-102
Catalogs. Follow its recommendations. Warning Notice
Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states. This
publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is essential
in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed to transport
The following warning information, Part Number LV4403-500, is
LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper handling procedures.
Refresher training shall be provided at least every three years and shall be documented.” included with each shipment of regulators to the first purchaser of the
Pamphlet 58 also states that “All regulators for outdoor installations, except regulators used for portable industrial
applications, shall be designed, installed or protected so their operation will not be affected by the elements (freezing product from the factory.
rain, sleet, snow, ice, mud or debris). This protection may be integral with the regulator.”
Vents must be clear and fully open at all times. An obstructed vent will prevent the regulator from functioning

This information is intended to be forwarded throughout the product


properly and may result in property damage and personal injury.
Regulators should be installed with the vent facing down or otherwise covered for protection.
Twin-Stage Regulators should be installed completely under cover and/or with screened vent pipe away adapters
that position both vents in a down position without obstructing flow through the vents.
distribution chain. Additional copies are available from RegO and
Make sure piping is clean and free from foreign material (such as dirt, corrosion, chips, pipe joint compound,
etc.) Always replace the pigtail when replacing a regulator. Thread sealant used on piping must be compatible
Authorized Product Distributors.
with LP-Gas.
Make sure the use and location of the regulator(s) as a component(s) of the LP-Gas system to be installed is
proper. (Avoid misusing LP-Gas equipment.) See the following RegO publications: L-500 & L-102 Catalogs and
the LP-Gas Serviceman’s manual.
For underground installations, make sure that water, mud, dirt, and insects cannot get into the regulator, and that
the regulator is easily accessible for regulator maintenance. Follow NPGA Bulletin 401. See RegO Safety Warning
“LP-Gas Regulators” found in the regulator section of the L-500 & L-102 Catalogs.
Check regulator and installation for leaks following NFPA #54 and NPGA Bulletin 403 “Pressure Testing and Leak
Checking LP-Gas Piping Systems”.
In selecting a label for posting at the installation site, consider RegO part number 2403-400 along with your
own, NPGA’s and others.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment.
See RegO Safety Warning “LP-Gas Regulators” found in the regulator section of the L-500 & L-102 Catalogs.

RegO requests that this information be forwarded to your customers. Additional copies are available from
RegO and your authorized RegO Distributor.
Printed in USA 08A-0910-0390
Part number LV4403-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

LV4403-500

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
A55
A

A56 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section B
Cylinder and Service Valves B B

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
B warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

B2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. B
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B3
LP-Gas Cylinder and Service Valves

Safety Warnings Purpose


In its continuing quest for safety, RegO publishes a series of bulletins explaining the hazards associated with
the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these factual bulletins will make
clear to LP-Gas dealer managers and service personnel, that the utmost care and attention must be used in
the installation, inspection, and maintenance of these products, or problems could occur which would result in
injuries and property damage.

The National Fire Protection Association NFPA 58 Liquefied Petroleum Gas Code - 2020 Edition states in
Section 4.4 Qualification of Personnel; ”Persons whose duties fall within the scope of this code shall be
provided with training that is consistent with the scope of their job activities and that includes proper handling
and emergency response procedures... Refresher training shall be provided at least every 3 years, initial and
subsequent training shall be documented”. These “RegO Safety Warnings” may be useful in training new
employees and reminding older employees of hazards that can occur. It is recommended that all employees
complete the Propane Education Research Council’s Certified Employee Training Program.

These functions, although simple, are extremely critical in the safe


Nature of Warnings operation of an LP-Gas cylinder system.

It is recognized that warnings should be as brief as possible, but the


Abuse of these valves, failure to follow a good installation and
factors involved in cylinder valve failure are many because of the
maintenance program and attempting to use cylinder valves
multiple functions the valve serves. If there is any simple warning, it
beyond their normal service life can result in extremely hazardous
would be:
conditions.

Important Factors:
Check cylinder valves for leaking components every time cylinders 1. Installation: It should not be necessary to remind the readers that
are filled. cylinder valves must be installed and used in strict conformance with
NFPA Pamphlet 58, and all other applicable codes and regulations.
Codes, regulations and manufacturers’ recommendations have
been developed by experts with many years of experience in the
LP-Gas industry in the interest of safety for users of LP-Gas and all
B The bulletin is not intended to be an exhaustive treatment of the
personnel servicing LP-Gas systems. Failure to fully follow these
subject of cylinder valves and certainly does not cover all safety
practices that should be followed in installation, operation and codes, regulations and recommendations could result in hazardous
maintenance of LP-Gas systems which include cylinder valves. installations.

2. The bonnet and stem seal assembly of a cylinder valve are


extremely critical, since any malfunction could cause external leakage
and spillage. Check bonnet to see that it is in proper position. If there
is any doubt about tightness of threaded connection between bonnet
and body, valve must be repaired in accordance with manufacturers’
repair instructions before cylinder is filled. Handwheel must be in
good condition, stem threads must not be worn or damaged and
bonnet must be properly assembled. This area should be examined
each time the cylinder if filled. A leakage test should be conducted
while the shut-off valve is in the open position during filling.

3. The cylinder outlet connection is usually a female POL. Threads


must be free of dents, gouges and any indication of excessive wear.
Seating surface inside this connection must be smooth and free
of nicks and scratches to ensure a gas tight seal when connected
to a male POL cylinder adapter. Cylinder adapter must spin on
freely all the way, without indication of drag, roughness or excessive
looseness, and must then be tightened with a wrench. Connection
must be checked for leakage.

4. The pressure relief valve is of critical importance: Its proper


LP-Gas Cylinder Valves operation is vital in avoiding excessive pressures during emergencies,
such as overfilling or exposure to excessive heat. No repair of this
These valves are mounted in DOT cylinders, and are intended to device is allowable. Relief valve should be visually inspected and
provide one or more of the following functions: checked for leaks each time the cylinder is returned for filling. All flow
passages must be clean and free of foreign material.
1. Vapor service shut-off
2. Liquid service shut-off (with excess flow valve)
3. Liquid filling
4. Pressure relief
5. Fixed liquid level gauge

B4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
LP-Gas Cylinder and Service Valves

Entire assembly must be free of dents, distortion or other indications


of damage. If relief valve appears too contaminated or damaged, the
cylinder valve must be replaced. (Caution: Eye protection must be
used when examining relief valves under pressure.)

5. The liquid service shut-off valve, with excess flow valve provided
on some cylinder valves, is also of critical importance. The excess
flow valve must be periodically tested for proper performance, in
addition to the inspection of the shut-off valve.

6. The fixed liquid level gauge on a cylinder valve is, when present,
essential to prevent overfilling the cylinder. The gauging valve must
operate freely, venting vapor when loosened, and sealing gas-tight
easily when tightened with the fingers. Gauge valves meant for
use with a socket key or screwdriver must also seal easily without
excessive torque. The fixed liquid level gauge diptube must be of
the proper length, and be in proper position. Periodic test should be
conducted by weighing the cylinder after filling, to determine that it
does not contain more than the allowable amount of LP-Gas. This At the very minimum, it is desirable that these customers:
check should be done periodically, and any time there is suspicion
that the gauge diptube may be damaged or broken. 1. Know the odor of LP-Gas and what to do in case they smell gas.
Use of the NPGA “Scratch ’n Sniff” leaflet could be productive.

2. Are instructed never to tamper with the system.

3. Know that when protective hoods are used to enclose regulators


and/or valves, that these hoods must be closed, but not locked.
Do Not Overfill Cylinders 4. Know the location of the cylinder shut-off valve in emergencies.

Do not fill a cylinder without first repairing or replacing the


cylinder valve, as required, if any defect is noted. B
While not required by codes, it is recommended that a plug or General Warning
suitable protection be inserted in the POL outlet of the cylinder
valve at all times except during filling and while connected for use.
This will guard against discharge of gas should the handwheel be All RegO Products are mechanical devices that will eventually
inadvertently opened while the cylinder is in storage or transit. This is become inoperative due to wear, contaminants, corrosion and
highly advisable for small cylinders that could be transported inside aging of components made of materials such as metal and rubber.
an automobile or trunk. It is important that proper wrenches and
adapters be used when filling, servicing and installing cylinder valves
in order to avoid damage to the valve or associated piping.

The environment and conditions of use will determine the safe service
life of these products. Periodic inspection and maintenance are
essential. Because RegO Products have a long and proven record
of quality and service, LP-Gas dealers may forget the hazards that
Since cylinders are often used by consumers without previous can occur because a cylinder valve is used beyond its safe service
knowledge of the hazards of LP-Gases and the LP-Gas dealers life. Life of a cylinder valve is determined by the environment in which
are the only ones who have direct contact with the consumers, it it “lives”. The LP-Gas dealers know better than anyone what this
is the dealers’ responsibility to make sure that his customers environment is. NOTE: There is a developing trend in state legislation
are properly instructed in safety matters relating to their and in proposed national legislation to make the owners of products
installation. responsible for replacing products before they reach the end of their
safe useful life. LP-Gas dealers should be aware of legislation which
could affect them.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B5
Thread Specifications

Because of the many thread forms available on equipment used in


Cylinder Valve Threads the LP-Gas industry today, the maze of letters, numbers and symbols
which make up various thread specifications becomes confusing. To
help eliminate some of this confusion, a brief explanation of some of
the more widely used thread specifications is shown below.

NGT and NPT Threads


Inlet Connections The NGT (National Gas Taper) thread is the commonly used valve-
to-cylinder connection. The male thread on the valve has about
two more threads at the large end than the NPT in order to provide
additional fresh threads if further tightening is necessary. Additionally,
the standard ¾” NGT valve inlet provides the greater tightness at the
bottom of the valve by making the valve threads slightly straighter
than the standard taper of ¾” per foot in NPT connections. In all other
respects NPT and NGT threads are similar.
Hand engagement of all
Overall length of all except NGT
Overall length of NGT

Outlet Connections
CGA Outlets
The CGA (Compressed Gas Association) outlets are standard for use
with various compressed gases. The relation of one of these outlets Copper Tubing
Cylinder
Valve
to another is fixed so as to minimize undesirable connections. They Nut
Outlet
have been designed to prevent the interchange of connections which
may result in a hazard.
CGA 182, or SAE Flare
This connection ensures a leak-tight joining of copper tubing to brass
3/8”-18 NPT Thread Connection
parts without the need for brazing or silver soldering. The common
This connection is also used for vapor or liquid withdrawal. It has a
size used on LP-Gas valves and fittings is 3⁄8” SAE (Society of
B 3⁄8” diameter thread, and 18 threads per inch, National Pipe Taper
Automotive Engineers) flare. Although this connection is referred
Outlet form.
to as a 3⁄8”, because 3⁄8” OD tubing is used, the thread actually
measures 5⁄8”. The specifications are .625 – 18 UNF – 2A – RH –
EXT, which means .625” diameter thread, 18 threads per inch, Unified
Fine Series Class 2 Tolerances, right-hand, external thread.

Cylinder
Nipple Valve
Nut Outlet

CGA 555 CGA 510 or POL


CGA 555 is the standard cylinder valve outlet connection for liquid Most widely used in this industry, POL is the common name for the
withdrawal of butane and/or propane. Thread specification is .903” – standard CGA 510 connection. Thread specification is .885” – 14
14 NGO – LH – EXT, which means .903” diameter thread, 14 threads NGO – LH – INT, meaning .885” diameter thread, 14 threads per inch,
per inch, National Gas Outlet form, left-hand external thread. National Gas Outlet form, left-hand internal thread. RegO POL outlet
connections for LP-Gases conform to this standard.

Cylinder Valve Outlet

Nipple
Nut

B6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
LP-Gas Cylinder and Service Valves

General Information O-Ring type stem seals are the most widely accepted in the industry.
The wide acceptance of RegO Cylinder Valves is based on their The simple, economical and long life design features a tapered and
reliable performance as well as their reputation for engineering and confined nylon seat disc which provides positive, hand-tight closings,
manufacturing excellence. and a faster filling cylinder valve.

Together with thorough testing, these efforts result in years of trouble- Pressure Relief
free service. RegO Cylinder Valves are listed by Underwriters’ RegO Valves have full-capacity “pop action” pressure reliefs with start
Laboratories and approved by the Bureau of Explosives for pressure to discharge settings starting at 375 PSIG.
relief valve operation, wherever applicable. See section on relief
valves for important information. A Valve for Every Need
RegO Cylinder Valves are available for all LP-Gas services; a wide
Reliability choice for domestic, commercial, industrial, RV, motor fuel, and lift
RegO Cylinder Valves are built with attention to each detail: truck applications.
Beginning with comprehensive inspection of forgings and machined
parts, and ending with intense quality testing on each individual valve Valves are available with a combination of options such as pressure
prior to shipment. reliefs, liquid level gauges, and liquid withdrawal tubes. Also available
for special applications are plumber’s pot valves, tamper resistant
Every valve must pass a stringent and comprehensive underwater valves for field service, and dual valves for simultaneous liquid and
leakage test. Additionally, valves with pressure reliefs are tested for vapor service.
proper pressure and operation, including reseating to ensure proper
opening and closing at required pressures. Those equipped with 2. Do not use excessive force in opening or closing the valves. The
excess flow checks are tested for compliance with published closing seat disc and diaphragm materials permit the valves to be opened
specifications, and tested to ensure minimum leakage after closing. and closed easily by hand. Never use a wrench on wheel handle
valves.
Instructions for the Proper Use and Applications
of RegO Cylinder Valves 3. When the design of the piping installation allows liquid to be locked
between two valves, a hydrostatic relief valve must be installed in the
1. Containers and pipe line should be cleaned thoroughly before line between the two valves. The pressures which can develop due
valves are installed. Large particles of solid foreign matter can cut the to temperature increase in a liquid full line are tremendous and can
seating surface of any resilient seat disc, causing the valve to leak. cause rupture of the line or damage to the valves.
Care must be exercised in inserting valves into lines or containers to
avoid damaging or exerting pressure against pressure relief valves 4. The valves are designed to withstand normal atmospheric B
and outlet connections. Use a minimum amount of a suitable luting temperatures. They should not, however, be subjected to abnormally
compound on the cylinder valve threads only. Excess amounts of high temperatures.
luting compound can foul the operating parts of the valves.

Heavy-Duty Valve Stem Seals


RegO Cylinder Valves utilize seat discs and stem seals which resist
deterioration and provide the kind of reliable service required for
LP-Gas utilization. Diaphragm or O-Ring stem seals are available.
Valves with diaphragm stem seals are recognized for their heavy-
duty body design and are suitable for use in cylinders up to 200 lbs.
propane capacity.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B7
Design Features of RegO Cylinder Valves

Valve Stems On 901, 9101, 9102 and Back Seat On 901, 9101, 9102 and
9103 Valves 9103 Valves
Are machined with a double lead thread Is metal-to-metal seating to provide
for quick opening and closing as well as added protection against leakage while
high lift. the valve is open. Back seat the valve
while in operation.

Forged Brass Body

Pressure Relief O-Rings


Provides quick discharge of excess For positive leak-proof seals under
pressure. Relief seat disc is special temperature and pressure variations.
resilient composition rubber.

Seat Disc
Tapered Seat Openings Is a tapered nylon in a fully confined
On 9101,9102 and 9103 Valves seat to ensure easy, leak-free, positive
Permit increased flow rates shutoffs. Seat disc also provides a
resulting in faster charging. separate swivel action to minimize
scoring by impurities.

B8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Heavy-Duty Cylinder Valves for Vapor Withdrawal
9103 Series

Application
This heavy duty cylinder valve is designed for vapor withdrawal of
DOT cylinders up to 100 lbs. propane capacity. It is used in domestic
hookups and industrial commercial installations.

Features
• Equipped with a fast filling throat and high lift, o-ring stem seal
design.

• Utilizes a nylon tapered seat design for positive closing.

• Available with a fixed liquid level gauge.

• Self-tapping screw secures handwheel to stem and reduces


possibility of handwheel vibrating loose while in transit.

Materials
Body............................................................................ Forged Brass
Handwheel........................................................................ Aluminum
Stem........................................................................................ Brass
9103D
O-Rings.................................................................. Resilient Rubber
Seat Disc................................................................................. Nylon
Relief Spring.............................................................. Stainless Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Fixed For Use in Approximate Filling Rate Liquid Flow, GPM Accessories
Pressure
Liquid Dip Tube Cylinders
Container Service Relief Pressure Drop Across Valves
Part Number Level Length w/ w/Propane
Connection Connection Valve POL Plug
Vent Deflector Capacity
Setting 10 PSIG 25 PSIG 50 PSIG 100 PSIG
Valve Up To:
9103D10.6 10.6”
Standard
9103D11.6 F. POL 11.6”
¾” M NGT 375 PSIG 100 lbs. 12.7 20.3 29.0 41.3 N970P
D9103D10.6 (CGA 510) 10.6”
#72 Low
D9103D11.6 Emission 11.6”

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B9
Tamper-Resistant Cylinder Valve with Outlet Check for Vapor Withdrawal
9103T9F

Application
This valve is designed for vapor withdrawal from and protection of
DOT cylinders up to 100 lbs. propane capacity. Ideal for cylinders
used in the field by construction crews, utility repair men and
plumbers.

Features
• Minimizes the risk of unauthorized persons withdrawing propane
from cylinders not in service. It is necessary to install a male POL
connection to open the outlet check to withdraw vapor from the
valve.

• Ball type excess flow located in the valve inlet protects against
excessive discharge if the cylinder is tipped or the hose ruptures.
Closing flow is 200 SCFH at 100 PSIG.

• Removable POL outlet and check mechanism make field


replacement of worn connections an easy process without
removing the valve from the cylinder.

• Outlet seal plug on a heavy duty chain prevents dirt from entering
POL when not in use.

• Nylon tapered seat design provides positive closure.

9103T9F

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
B Stem........................................................................................ Brass
O-Rings.................................................................. Resilient Rubber
Seat Disc................................................................................. Nylon
Relief Spring.............................................................. Stainless Steel
Plug......................................................................................... Brass

10
REGO

YEAR
WARRANTY

Ordering Information
Approximate Filling Rate Liquid Flow, GPM
Fixed Liquid
Part Container Service Pressure Relief For Use in Cylinders w/
Level Vent Pressure Drop Across Valves
Number Connection Connection Valve Setting Propane Capacity Up To:
Valve Style
10 PSIG 25 PSIG 50 PSIG 100 PSIG
¾” F. POL 375
9103T9F None 100 lbs. 5.0 7.6 10.7 14.9
M. NGT (CGA 510) PSIG

NOTE: These valves incorporate an excess flow valve.


Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Cylinder Valve for RV and Small ASME System Vapor Withdrawal
9106CO

Application
Designed especially for vapor withdrawal service in small ASME
containers with surface area up to 23.8 square feet. UL flow capacity
is 645 SCFM/air.

Features
• One-piece relief valve is shielded from tampering and damage.

• Relief is forged as part of the body for extra strength.

• 312 PSIG Relief Valve setting.

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Stem........................................................................................ Brass
Seat Disc................................................................................. Nylon
Relief Spring.............................................................. Stainless Steel
9106CO

3 1⁄4 "
Approx.

10
REGO

YEAR
WARRANTY

2 1⁄16 " 1 3⁄ 8 "

Ordering Information
Container Service Fixed Liquid Level Pressure Relief Valve For Use In Cylinders w/ Propane Flow Capacity
Part Number
Connection Connection Vent Valve Style Setting Capacity Up To SCFM/Air
¾” F. POL 312 ASME
9106CO none 645
M. NGT (CGA 510) PSIG Tanks*
* Surface area up to 23.8 square feet.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B11
Cylinder Valve for Liquid Withdrawal
9107K8A

Application
Equipped with excess flow valves and liquid withdrawal tubes, they
are designed for liquid withdrawal of DOT cylinders up to 100 lbs.
propane capacity. They are most often used with heavy BTU loads
found in industrial uses.

Features
• O-ring stem seal design.

• Nylon tapered seat disc for positive closure.

• Self-tapping screw secures handwheel to stem and reduces


possibility of handwheel vibrating loose while in transit.

• Features ball check excess flow valve.

• Furnished with ½” O.D. brass withdrawal tube with “T’’ dimension


of 44”.

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Seat Disc................................................................................. Nylon
O-Rings.................................................................. Resilient Rubber
Relief Spring.............................................................. Stainless Steel
Stem........................................................................................ Brass

10
REGO

YEAR
WARRANTY

9107K8A

Ordering Information
Container
Part Number Service Connection Fixed Liquid Level Vent Valve Dip Tube Length Liquid Withdrawal Tube Length
Connection
9107K8A Standard
¾” M. NGT CGA 555 11.6” 44”
D9107K8A #72 Low Emission

Approximate Filling Rate Liquid Flow, GPM Closing Flow (LP-Gas) *


Pressure Relief Valve For Use in Cylinders w/Propane
Pressure Drop Across Valves Vapor
Setting Capacity Up To: Liquid
10 PSIG 25 PSIG 50 PSIG 100 PSIG 25 PSIG Inlet 100 PSIG Inlet
375 PSIG 100 lbs. 3.3 5.4 7.7 11.1 525 SCFH 1,000 SCFH 1.7 GPM
*Closing flows based on 3⁄8” O.D. withdrawal tube 44” long or less attached.

IMPORTANT: ¼” O.D. pigtails or POL connections for ¼” O.D. pigtails should not be used with these valves.
NOTES: To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated
when in use. These valves incorporate an excess flow valve. Refer to L-500 / Section F, for complete information regarding selection, operation and
testing of excess flow valves.

B12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Service Valves for ASME and DOT Containers or Vapor Fuel Line Applications
901C1, 9101C, 9101D, 9101R and PT9102 Series

Application
Designed for vapor withdrawal service on ASME and DOT containers
or in fuel line applications. Since none of these valves have an
integral pressure relief valve, they may only be used as an accessory
valve on containers that have an independent pressure relief valve
sufficient for that container’s capacity.

Features
• O-Ring stem seal design provides positive seal.

• Metal-to-metal back seat provides added protection against


leakage while the valve is open.

• Valves with fixed liquid level gauges permit operator to quickly


determine when the maximum permitted filling level of the
container is reached.
901C1
• 9101R Series with MultiBonnet® assembly allows quick and easy
repair of bonnet.

• PT9102R Series With the service valve closed the pressure


test/Presto-Tap® port is isolated from the container. This
will allow a high pressure leak test to be conducted without
disconnecting the pigtail from the service valve. For more
information, see page C13 on this feature

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Stem........................................................................................ Brass 9101R1
O-Rings.................................................. Resilient Synthetic Rubber
Seat Disc................................................................................. Nylon B

10
REGO

YEAR
WARRANTY

PT9102 9101D
Ordering Information
Approximate Filling Rate Liquid Flow, GPM
Fixed
Liquid Pressure Drop Across Valve
Container Service Level Vent Diptube Length
Part Number Bonnet Style Connection Connection Valve 10 PSIG 25 PSIG 50 PSIG 100 PSIG w/ Deflector Ready To Go™
901C1 5.3 8.2 10.8 14.2
No N/A
9101C1 8.8 12.4 15.8 21.7
Standard
9101D11.1 11.1
Yes 8.6 12.7 16.3 22.3 NA
9101D11.7 11.7
9101R1 No N/A
MultiBonnet®
9101R11.1 11.1
assembly
9101R11.7 F. POL 11.7 No
¾” M. NGT
9102D11.1 CGA 510 11.1
Standard Yes
9102D11.7 11.7
7.6 11.7 15.2 20.6 Plugged
9102R11.1 11.1
9102R11.7 11.7
MultiBonnet®
PT9102R1 No N/A
assembly
PT9102R11.1 11.1 Yes
Yes
PT9102R11.7 11.7
Note: Since these valves have no integral pressure relief valve, they can be used on any container with an independent relief device sufficient for that tank’s capacity.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B13
Service Valves for ASME and DOT Containers or Vapor Fuel Line Applications
D9101D/R, D9102D/R and DPT9102D/R Series

Application
Designed for vapor withdrawal service on ASME and DOT containers
or in fuel line applications. Since none of these valves have an
integral pressure relief valve, they may only be used as an accessory
valve on containers that have an independent pressure relief valve
sufficient for that container’s capacity. The Fixed liquid level gauge is
provided with a #72 low Emission fixed liquid level vent valve.

Features
• O-Ring stem seal design provides positive seal.

• Metal-to-metal back seat provides added protection against


leakage while the valve is open. DPT9102

• Valves with fixed liquid level gauges permit operator to quickly


determine when the maximum permitted filling level of the
container is reached.

• D9101R and D9102R Series with MultiBonnet® assembly allows


quick and easy repair of bonnet.

• DPT9102R Series With the service valve closed the pressure


test/Presto-Tap® port is isolated from the container. This
will allow a high pressure leak test to be conducted without
disconnecting the pigtail from the service valve. For more
information, see page C13 on this feature

• #72 Low Emission Fixed Level Vent Valve.

D9101D
Materials
Body............................................................................ Forged Brass
B Handwheel......................................................... Aluminum Die Cast
Stem........................................................................................ Brass
O-Rings.................................................. Resilient Synthetic Rubber
Seat Disc................................................................................. Nylon

10
REGO

YEAR
WARRANTY

Ordering Information
Approximate Filling Rate Liquid Flow, GPM
Fixed
Liquid Pressure Drop Across Valve Dip Tube
Container Service Level Vent Length w/
Part Number Bonnet Style Connection Connection Valve 10 PSIG 25 PSIG 50 PSIG 100 PSIG Deflector Ready To Go™
D9101D11.1 11.1
Standard 8.6 12.7 16.3 22.3
D9101D11.7 11.7
N/A
D9101R11.1 MultiBonnet® 11.1
D9101R11.7 assembly 11.7
D9102D11.1 11.1
Standard
D9102D11.7 F. POL #72 Low 11.7
¾” M. NGT Plugged
D9102R11.1 CGA 510 Emission 11.1
MultiBonnet®
7.6 11.7 15.2 20.6
D9102R11.7 assembly 11.7
DPT9102D11.1 11.1
Standard N/A
DPT9102D11.7 11.7
DPT9102R11.1 MultiBonnet® 11.1
Yes
DPT9102R11.7 assembly 11.7
Note: Since these valves have no integral pressure relief valve, they can be used on any container with an independent relief device sufficient for that tank’s capacity.

B14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Service Valves for ASME Motor Fuel Containers
901C, 9101H, and 9101Y Series

Application
Designed specifically for vapor or liquid withdrawal service on
ASME motor fuel containers. Since none of these valves have an
integral pressure relief valve, they may only be used as an accessory
valve on containers that have an independent pressure relief valve
sufficient for that container’s capacity.

The integral excess flow valve found in all these service valves helps
prevent excessive product loss in the event of fuel line rupture.

When installed for liquid withdrawal, the 9101H6 has provisions


for attachment of a liquid withdrawal tube. All other valves must 901C5
be installed in containers that have provisions for a separate liquid
withdrawal.

To ensure proper functioning and maximum protection from integral

10
excess flow valves, these service valves should be fully opened and REGO
backseated when in use.

Features YEAR
• Incorporates integral excess flow valve and shut-off valve in one
unit. WARRANTY

• Double lead thread provides faster opening and closing. 9101H5


• O-Ring stem seal design provides positive seal.

• Tapered and confined seat disc provides positive shut off.

• Metal-to-metal back seat provides added protection against 11/10”


leakage while the valve is open.

• 9101H6 equipped with a ¼” NPT internal thread for the addition of B


a liquid withdrawal tube. 19/32”

• 9101Y Series features a 60º angled outlet connection to facilitate


easier and simpler fuel line make-up.
17/32”

9101H6
123/64”
Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Stem........................................................................................ Brass
O-Rings.................................................. Resilient Synthetic Rubber
Seat Disc................................................................................. Nylon

Ordering Information 9101Y5H


Closing Flow (LP-Gas)
Vapor
Container Service Liquid Withdrawal
Part Number Connection Connection Connection 25 PSIG Inlet (SCFH) 100 PSIG Inlet (SCFH) Liquid GPM
901C3 350*** 605*** 1.5***
F. POL CGA 510
901C5 550*** 1050*** 2.6***
None
9101H3 430** 800** 1.5**
⅜” SAE Flare
9101H5* ¾”M. NGT 765** 1300** 3.6**
9101H6* ¼” NPT 550**** 1050**** 2.6****
60° Angle
9101Y5H* None 765** 1300** 3.6**
⅜” SAE Flare

* Heavy-duty models
** Based on 3⁄8” O.D. pigtail, 20” long or less, connected to valve outlet. For greater lengths, the pigtail must have a larger O.D.
*** Same as (**). In addition, ¼” O.D. pigtails or POL connections for ¼” O.D. should not be used with this valve.
**** Based on 3⁄8” O.D. pigtail; 20” long or less, connected to valve outlet. Also based on ¼” pipe size dip tube, 42” long or less, attached to special inlet connection. For longer pigtail lengths, the
diameter of the pigtail must be increased.
NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B15
Service Valves for DOT Fork Lift Containers
9101P5 and 9101P6 Series

Application
Designed specifically for vapor or liquid withdrawal service on DOT
fork lift containers. Valves with 1.5 GPM closing flow are for use in 1¼”
small and medium size lift truck applications, while those with 2.6
GPM closing flow are for large lift trucks. Since none of these valves
have an integral pressure relief valve, they may only be used as an
accessory valve on containers that have an independent pressure
relief valve sufficient for that cylinder’s capacity.
2¾” Approx.
The integral excess flow valve found in all these service valves helps
prevent excessive product loss in the event of fuel line rupture.

When installed for liquid withdrawal, the 9101P6 Series has


provisions for attachment of a liquid withdrawal tube. The 9101P5
Series must be installed in containers that have provisions for a
separate liquid withdrawal.

To ensure proper functioning and maximum protection for integral


excess flow valves, these service valves should be fully opened and 3
backseated when in use.

Features 9101P5
• Incorporates integral excess check valve and shut-off valve in one 9101P5H
unit.

• Special 1.5 GPM closing flow on select valves provided especially


for lift trucks and equipment with smaller engines.

• Double lead stem thread provides faster opening and closing.

• O-Ring stem seal design provides positive seal. 213/16 ”


Open
4.46 OPEN

B • Tapered and confined seat disc provides positive shut-off.

• Metal-to-metal back seat provides added protection against


leakage while the valve is open.

• 9101P6 Series equipped with a ¼” NPT internal thread for the


addition of a liquid withdrawal tube.

123/32 ”

Materials 1¼”
9101P6
Body............................................................................ Forged Brass 9101P6H
Handwheel......................................................... Aluminum Die Cast

10
Stem........................................................................................ Brass REGO
O-Rings.................................................. Resilient Synthetic Rubber
Seat Disc................................................................................. Nylon

YEAR
WARRANTY
Ordering Information
Approximate Filling Rate Liquid
Closing Flow (LP-Gas) Flow, GPM Accessories

Vapor Pressure Drop Across Valve ACME Check Connectors


Liquid
Part Container Service Withdrawal 25 PSIG Inlet 100 PSIG Liquid 25 50 100
Number Connection Connection Connection (SCFH) Inlet (SCFH) (GPM) 10 PSIG PSIG PSIG PSIG Male Female Cap
9101P5 430 900 1.5
None 5.0 7.6 10.7 14.9
9101P5H 550 1050 2.6 7141M-40
¾” M. NGT ⅜” M. NPT 7141M 7141F
9101P6 430 900 1.5 or 7141FP
¼” NPT 4.5 7.2 10.3 14.8
9101P6H 550 1050 2.6
Note: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Cylinder Valve for Propylene Service
9104PT and 9104PPA

Application
Designed for vapor withdrawal from and protection of DOT cylinders
up to 100 lbs. propylene capacity with pressure ratings such as
4B-260, 4BA-260, and 4BW-260 cylinders.

Features
• Nylon tapered seat designed for positive closing.

• Relief is forged as part of the body for extra strength.

• Available with Fixed Liquid Level Gauge.

• 435 PSIG Relief Valve Setting.

• Meets TB27 requirements.

• / ” Markings.
3 32

Materials
Body............................................................................ Forged Brass
Handwheel........................................................................ Aluminum
Stem........................................................................................ Brass
Seat Disc.................................................................................. Viton
Relief Spring.............................................................. Stainless Steel
Relief Valve Setting................................................. 435 PSIG TB27

9104PT
44.055
1
/16” APPROX
Approx
Open OPEN

33.808
13
/16”APPROX
Approx
CLOSED
Closed B

1(2.031)
17
/32”

1(1.594)
19
/32” (1.359)
1 23
/64”

10
REGO

9104PPA

YEAR
WARRANTY

Ordering Information
For use in Cylinders
Container Service Fixed Liquid Level Pressure Relief Valve w/ Propylene Capacity
Part Number Connection Connection Vent Valve Style Dip Tube Length* Setting up to:
9104PPA N/A N/A
*9104PT10.1 ¾” M.NPT F.POL - (CGA 510) 10.0” 435 PSIG 100lbs
Knurled
*9104PT10.7 10.7”
* Valve can be ordered with other dip tube lengths. Specify required length when ordering. X = diptube size

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B17
“Dual” Cylinder Valve for Simultaneous Liquid and Vapor Withdrawal
8556

Application
This dual cylinder valve was designed especially for industrial uses.
It increases the cylinder’s flexibility by permitting DOT cylinders
up to 100 lbs. propane capacity to be used interchangeably or
simultaneously for either liquid or vapor withdrawal.

Features
• Two separate flow channels in the body permit vapor and/or liquid
withdrawal alternately, or simultaneously.

• Outlet connections have two different fittings.

• Handwheels are equipped with appropriate “liquid” or “vapor”


identification labels.

• Furnished with a ⅜” O.D. stainless steel liquid withdrawal tube


with a “T” dimension of 44”.

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
B Stem........................................................................................ Brass
Seat Disc................................................................................. Nylon
O-Rings.................................................................. Resilient Rubber
Relief Spring.............................................................. Stainless Steel

10
REGO
8556

YEAR
WARRANTY

Ordering Information
Container Service Connection
Part Number Fixed Liquid Level Vent Valve Style Liquid Withdrawal Tube Length
Connection Vapor Liquid

8556 ¾” M. NGT F. POL (CGA 510) CGA 555 None 44”

Approximate Filling Rate Liquid Flow, GPM


Pressure Relief Valve For Use in Cylinders w/Propane Liquid Closing Flow*
Pressure Drop Across Valves
Setting Capacity Up To: (LP-Gas)
10 PSIG 25 PSIG 50 PSIG 100 PSIG
375 PSIG 100 lbs. 6.6 10.0 14.5 21.0 2.3 GPM

*
To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use.
NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

B18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Adhesive Warning Labels
901-400 and 903-400

These adhesive warning labels are intended for application as close


as possible to the cylinder valve and/or service valve.

The basic information contained on the label is intended for the Part Number
benefit of the user of the valves and is not intended to be an “all- Adhesive Label Primarily for Fork Lift
901-400
inclusive” product warning. Cylinders
Adhesive Label Primarily for Small
These labels are printed on a heavy duty material with pressure 903-400
DOT Cylinders
sensitive adhesive backing. The ultra-violet ink stands up well when
Adhesive Label Primarily for Cylinder
exposed to the environment. 903-500
and Service Valves

LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE


DANGER! KEEP CYLINDER OUT OF THE REACH OF CHILDREN WARNING!
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL, OR HEAR THIS HISS OF ESCAPING GAS... IMMEDIATELY GET AWAY FROM THIS CYLINDER!
CALL YOUR LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT USE OR STORE IN BUILDING OR ENCLOSED AREA. FOR OUTDOOR USE ONLY.
This cylinder contains highly flammable LP-Gas under pressure. A serious fire it is obstructed, the entire cylinder valve must be replaced. The Shut-Off Valve may require 1. Do not use this cylinder without first reading the instructions accompanying the appliance with which
or explosion can result from leaks and misuse or mishandling of the cylinder periodic repair or replacement. this cylinder
is intended to be used.
and its valve. Do not carry, hold or lift the cylinder by its valve. Do not Before the cylinder is filled for the first time, it must be purged of air. 2. Before connecting the Cylinder Valve outlet connection to an appliance,
expose to fire or temperatures above 120°F (49°C). Total liquid volume must never exceed the amount designated by make sure the connection does not contain dirt or debris. These may cause
The Cylinder Valve incorporates a Shut-Off Valve and Pressure Relief Valve. DOT for this cylinder. the connection to leak or may impair the functioning of the regulator, creating
The Pressure Relief Valve can expel a large jet of LP-Gas into the air if the cylin- a hazardous condition.
If the cylinder has a Fixed Liquid Level Gauge, filling should stop the
der is (1) exposed to high temperatures - over 120°F (49°C), or (2) overfilled and moment a white LP-Gas cloud is emitted from it’s bleed hole. Keep the 3. When connecting the Cylinder Valve outlet to an appliance (CAUTION...
exposed to a temperature higher than the temperature at the time it was filled. counterclockwise thread), make sure the connection is tight. Check for leaks
DANGER LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE WARNING Never attempt to fill this cylinder yourself. Do not tamper with it
Vent Valve closed tightly at all other times.
Keep this cylinder firmly secured in an upright position at all times. Do not
with a high quality leak detection solution (leaks cause bubbles to grow). If
KEEP CYLINDER OUT OF THE REACH OF CHILDREN or attempt repairs. the connection leaks after tightening, close cylinder valve, disconnect it from
lay it on its side during transport, storage or use. In other than an upright posi- the appliance, insert the P.O.L. plug and immediately return the cylinder,
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL, OR HEAR THIS HISS OF ESCAPING GAS... Only trained LP-Gas Dealer personnel should be permitted to fill this tion, liquid LP-Gas may flow or leak. This liquid can cause skin burns, frostbite with the Cylinder Valve attached to your LP-Gas Dealer for examination.
IMMEDIATELY GET AWAY FROM THIS CYLINDER! CALL YOUR LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO cylinder and to repair or replace its valve. Each time the cylinder is and other serious injuries in addition to those caused by fire or explosion.
filled, the entire Cylinder Valve must be checked for leaks (with a leak This cylinder must be used only in compliance with all applicable laws and
REPAIR. DO NOT USE OR STORE IN BUILDING OR ENCLOSED AREA. FOR OUTDOOR USE ONLY. When not in use: Close the Shut-Off Valve. Insert a protective plug (P.O.L. regulations, including National Fire Protection Association Publication #58,
detection solution...leaks cause bubbles to grow). The Shut-Off Valve and plug) into the Cylinder Valve outlet. (CAUTION...counterclockwise thread.)
This container is filled with highly flammable LP-Gas under pressure. A serious fire Do not allow any overfill. If the fixed liquid level gauge is used during filling, filling Fixed Liquid Level Gauge (if incorporated) must be checked for proper which is the law in many states. A copy of this Publication may be obtained
or explosion can result from leaks and misuse or mishandling of the container and should stop the moment a white LP-Gas cloud is emitted from its bleed hole. Keep
The P.O.L. plug must be inserted whenever the cylinder is stored, manually
operation. The Pressure Relief Valve must be checked to ensure that is it moved, or transported by vehicle. by writing NFPA, Batterymarch Park, Quincy, MA 02269.
its valves. Do not move, hold or lift the container by any of its valves. Do not expose the vent close tightly at all other times. Each time the container is filled, it must be completely unobstructed and that it has no physical damage. CAUTION...
to fire or temperature above 120°F (49°C). Do not over fill. checked for leaks (with a leak detection solution...leaks cause bubbles to grow).
eye protection must be worn when examining relief valve. This valve cannot be repaired. If WHEN MAKING CONNECTIONS TO AN APPLIANCE:
This container incorporates a pressure relief valve. The pressure relief valve can Do not disconnect or connect this container without first reading the instructions DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL! DO NOT FILL THIS CYLINDER UNLESS THIS LABEL IS READABLE!
expel a large jet of LP-Gas into the air if the container is (1) exposed to high tem- accompanying the vehicle or appliance with which this container is intended to be ADDITIONAL SAFETY INFORMA- Elon, NC 27244 USA • www.regoproducts.com Printed in U.S.A. 06-0414-0384
peratures over 120°F (49°C) or (2) overfilled and exposed to a temperature higher used. CAUTION... No smoking while connecting or disconnecting this container. TION IS AVAILABLE FROM:
than the temperatures at the time it was filled.
Phone (336) 449-7707 • Fax (336) 449-6594
R PRODUCTS Warning 903-400
Make sure the service valve is shut of tightly before beginning to assemble or
The pressure relief valve is equipped with a protective cover. The protective disassemble the coupling. Liquid LP-Gas may flow or leak from the coupling.
cover must remain in place at all times except when inspecting the valve. CAU- This liquid can cause skin burns, frost bite and other serious injury in addition
TION...Use eye protection. If dust, dirt, moisture or other foreign material collect
in the valve, it may not function properly to prevent container rupture or minimize
product loss after opening.
to those caused by fire and explosion. CAUTION... Wear proper skin and eye
protection. Any gasket or o-ring in the coupling must be routinely checked for wear
and replaced as required.
903-400
Each time the container is filled, the pressure relief valve must be checked to en- After connecting the coupling, make sure the connection is leak tight. Check for
sure that it is completely unobstructed and that it has no physical damage. If there leaks with a leak detection solution (leaks cause bubbles to grow). If the connec-
is any doubt about the condition of the valve, the container must be removed from tion leaks after tightening, close the service valve, disconnect the coupling and
service and the pressure relief valve must be replaced. remove from service.
Only trained personnel should be permitted to fill this container. Before the con- When not in use, keep the service shut-off valve closed. When in use, keep the
tainer is filled for the first time, it must be purged of air. The total liquid volume of service valve fully open. Keep this equipment out to the reach of children.
LP-Gas must never exceed the amount designated by applicable filling density
This container must be used only in compliance with all applicable laws and regula-
regulations for this container.
tions, including National Fire Protection Association Publication #58, which is the
Make sure the protective cap is in place on the ACME threaded filler valve at all law in many states. A copy of this publication may be obtained by writing NFPA,
times. Never insert a screwdriver or other tool into the valve as it can damage the Batterymarch Park, Quincy, MA 02269.
seal or guide and cause an uncontrolled leak.

DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL.


DO NOT FILL THIS CONTAINER UNLESS THIS LABEL IS READABLE.
ADDITIONAL SAFETY INFORMA- Elon, NC 27244 USA • www.regoproducts.com Printed in U.S.A. 04-0414-0386
TION IS AVAILABLE FROM: Phone (336) 449-7707 •Fax (336) 449-6594 Warning 901-400
R PRODUCTS

901-400

The following warning information, Part Number 903-500, is included DANGER READ THIS FIRST WARNING
with each shipment of cylinder valves and service valves to the first LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
purchaser of the product from the factory. ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Make sure you are thoroughly trained before you attempt any valve installation, maintenance or repair.

This information is intended to be forwarded throughout the product


Improper conditions or procedures can cause accidents resulting in property damage and personal injury.
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &

distribution chain. Additional copies are available from RegO and


Maintenance” and RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and
“LP-Gas Filler and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve
sections of the L-500 & L-102 Catalogs. Follow their recommendations.
Authorized Product Distributors. Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is
essential in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed
to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper
handling procedures. Refresher training shall be provided at least every three years and shall be documented.”
Make sure this valve is the proper one for this installation. Avoid misusing LP-Gas equipment.
Apply thread joint compound compatible with LP-Gas on valve external threads only. Make sure compound
never comes into contact with other parts of the valve.
Install valves by applying force to wrenching flats only.
Tighten pipe threads approximately 1 to 1½ turns beyond the hand-tight insertion point using a wrench which
avoids damage to other valve parts.
Check for damage and proper operation after valve installation. Check that the valve is clean and free of
foreign material.
Check container-valve connection with a non-corrosive leak detection solution before filling with LP-Gas.
Purge container before filling with LP-Gas (refer to the RegO LP-Gas Serviceman’s Manual for recommended
procedure).
Test excess flow check valve for proper operation before placing into service. See NPGA Bulletin 113 for
recommended procedure.
Check outlet connection make-up for leaks with a non-corrosive leak detection solution when placing
into service.
RegO Filler Valves: To prevent damage to the internal checks when it is necessary to utilize an unloading
adapter, use ONLY RegO 3119A, 3120 and 3121 Unloading Adapters with RegO Filler Valves. Carefully
follow the instructions supplied with these unloading adapters.
If container is not being placed into service at the present time, insert plug or cap onto the outlet connection.
In selecting a label for posting at the installation site, consider RegO part number 901-400 or 903-400 along
with your own, NPGA’s and others.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment.
See RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and “LP-Gas Filler
and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve sections of the
L-500 & L-102 Catalogs.

RegO requests that this information be forwarded to your customers. Additional copies are available from
RegO and your authorized RegO Distributor.
Printed in USA 09A-0910-0686
PRODUCTS R Part number 903-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

903-500

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
B19
B

B20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section C
Multivalve® Assemblies C C

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
C warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

C2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. C
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C3
RegO Multivalve® Assemblies

General Information Comprehensive Testing —


• Every Multivalve® assembly must pass a stringent underwater
RegO Multivalve ® assemblies were pioneered in the 1930’s. By leakage test prior to shipment.
combining several valve functions in one unit, Multivalve® assemblies
made possible new and more practical tank designs (fewer openings • Multivalve® assemblies with pressure relief valves are individually
and smaller, less cumbersome protective hoods). They received tested and adjusted to ensure proper pressure settings.
immediate acceptance. • Those equipped with excess flow checks are tested for compliance
with published closing specifications and for leakage after closing.
The Multivalve ® assembly design has kept pace with changing
industry needs over the years. They are as popular as ever; still Pressure Relief Valves and Other Devices —
keeping fabricating costs down and reducing operating expenses for • Multivalve® assemblies equipped with integral pressure relief
the LP-Gas dealer. devices employ full-capacity, “pop-action” reliefs with set pressures
of 250 psig for ASME use and 375 psig for DOT cylinders.
RegO Multivalve® assemblies Reduce the Cost of Fabrication by
• Combining several valve functions in one less expensive body. Double Back-Check Filler Valves —
• Reducing the number of threaded openings in ASME containers. • Multivalve ® assemblies with filling connections have double
• Diminishing the size and cost of protective hoods. backcheck safety. If the upper check ceases to function, the lower
• Providing generous sized wrenching bosses for quick, easy stand-by check will continue to protect the filling connection from
installation. excessive leakage.
RegO Multivalve® assemblies Reduce LPG Dealer Expenses by Ease of Maintenance —
• Permitting on-site filling of 100 lb. to 420 lb. DOT cylinders, thus • Standardization of parts makes it possible for one repair kit to
eliminating cylinder return and interrupted customer service. maintain the bonnet assemblies of RegO cylinder valves, service
• Providing well-placed hose connections for easy filling. valves, motor fuel valves, and Multivalve® assemblies.
• Allowing ample space for secure attachment and easy removal of
the regulator. RegO Multivalve® assemblies fit every LP-Gas need.
• Providing substantial savings of bonnet repairs on valves with the • Wide selection of Multivalve® assemblies for domestic, commercial,
MultiBonnet® assembly. and industrial needs are available.
RegO Multivalve® assemblies Satisfy Customer Demands for • Multivalve ® assemblies may be ordered with pressure relief,
Tough, Safe Equipment with These Features liquid level tube, filler valve, vapor equalizing valve, internal pipe
connections, liquid filling and withdrawal connections, and ¼” NPT
Heavy-Duty Valve Stem Seals — tapped opening for pressure gauge with or without steel plug.
• Tapered nylon disc in a fully confined seat resists deterioration and
provides hand-tight closings over a long service life.
C
Design Features of RegO Multivalve® Assemblies

Seal Cap
Molded from tough, resilient
plastic to protect threads
and internal working parts.
Designed to protect the filler UL Shear Point
opening against dirt and other Provides for a shear just
foreign materials. Also acts below the ACME threads to
as a secondary pressure seal. protect the container in case
of a pullaway while the hose
Long Wearing Gasket is connected. The ACME
Permits leak-free, hand-tight connection should shear off
connection of the hose on an angle pull, leaving the
coupling to the filler valve. body and check assembly of
the valve still in place.
Forged Brass Body
Filler Seat Disc
Fabricated of special
synthetic composition and
made extra thick for
longer life.
MultiBonnet® assembly
Designed to allow quick and Valve Guide
easy repair of bonnet packings on A precision machined “stem”
Multivalve® assemblies on to ensure positive alignment
active propane systems.
“Pop Action” Pressure Relief
Provides quick release of
excess pressure. Relief seat
disc is special resilient
composition rubber designed
to resist bonding to the
valve seat even after years
of service.

C4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO MultiBonnet® Assemblies

Design Features of the MultiBonnet® assembly

Handwheel
Aluminum die cast handwheel.

Non-Rising Stem
Designed to allow easy backseating and long
service life.

Upper Packing Assembly


Contains both internal and external o-rings.
Provides leak resistant performance.

Internal O-ring

Lower Bonnet and Stem Assembly


Machined brass construction offers durability to
bonnet design.

External O-ring

Nameplate C
Provides easy identification of the RegO
MultiBonnet® assembly.

Teflon Backseat
Provides for upper packing isolation when valve
is fully open.

Machined Double Lead Threads


Provides for quick opening and closing of the
valve.

Shut-off Seat Disc


Tapered nylon disc is retained in a fully confined
seat that helps ensure positive shut-offs.

Application
The MultiBonnet® assembly is designed to allow quick and easy repair • Available on certain new Multivalve® assemblies and service
of bonnet packings in certain Multivalve ® assemblies and service valves as well as repair assemblies for many existing RegO
valves on active propane systems. It allows you to repair valve bonnet valves.
stem o-ring leaks in minutes, without interrupting gas service to your • UL listed as a component of valve assembly.
customers.
Here’s How The MultiBonnet® assembly Works
• Eliminates the need to evacuate tanks or cylinders to repair the
• When the valve is fully open, only the lower stem will rise and
MultiBonnet® assembly packing.
backseat against the teflon washer which isolates the upper
• Two section design allows repair of MultiBonnet® assemblies on packing.
active propane systems without interruption in gas service or
• This allows you to remove the upper packing nut, which contains
shutting off appliances downstream. This helps to prevent time
the o-rings, and replace it while the valve is fully open and gas
consuming relighting of pilots, special appointments, and call
service not interrupted.
backs.
• Cost of replacing the MultiBonnet® assembly packing is only 1/3
as much as replacing a complete bonnet assembly—not including
time cost savings, which can be substantial.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C5
ASME Multivalve® Assemblies for Vapor Withdrawal G8475RL Series
Valves with Presto-Tap® Valves PG8475 Series

Application
These Multivalve® assemblies are designed for use in single opening
ASME containers equipped with a 2½” M. NPT riser. They can be
used with underground ASME containers up to 639 sq. ft. surface
area, and above ground ASME containers up to 192 sq. ft. surface
area. A separate opening is required for liquid withdrawal. The
MultiBonnet® assembly is standard on this valve.
The 8474L-50L Extended Filler Valve Kit is designed to extend
the filler valve section upward, when it is necessary to allow for an
extended filler connection.

Features 8475L-50L
• The most complete Multivalve® assembly in the LP-Gas industry.
• Combines low emission double back check filler valve, vapor
equalizing valve, pressure relief valve, service valve, fixed liquid
level gauge, “junior” sized float gauge flange opening and a
plugged pressure gauge opening.
• Double back check filler valve is low emission, 2.13cc at
disconnection with no reduction in fill rates.
• Designed for installation of a ⅛” FNPT pressure gauge
or pressure gauge connection. The pressure test port will
communicate to the downstream side of the service valve.
• PG8475RL Version: With the service valve closed the PG8475RL
pressure test/Presto-Tap® port is isolated from the container.
This will allow a high pressure leak test to be conducted without Reduced area above
disconnecting the pigtail from the service valve. For more the seat and unique
information see page C12. seat disc design
• Vapor equalizing valve with excess flow has increased capacity
matched to the filler valve.
• Internal threads accommodate 2½” M. NPT riser pipe connection
and a ¾” F. NPT connection for a customer furnished liquid baffle 6¾” Approx.
tube. for G8475RL
C • The MultiBonnet® assembly allows quick and easy repair of
bonnet.
53/16” 8⅛” Approx. for
Approx. G8475RLW

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Valve Stems............................................................................. Brass ¾” NPT THD. for 2½” NPT Riser
O-Rings.................................................................. Resilient Rubber standard weight baffle 30”
Pipe Connection
Seat Disc (shut-off valve)........................................................ Nylon pipe length to suit tank
Seat Disc (other).................................................... Resilient Rubber (Furnished by customer)
Relief Spring.............................................................. Stainless Steel
Approximate Filling Rate Liquid Flow, GPM

10
REGO Pressure Drop Across Valve
Part Number 10 PSIG 25 PSIG 50 PSIG 100 PSIG
G8475RL
YEAR
G8475RLW 42 72 98 125
WARRANTY
PG8475RL

Ordering Information
Vapor Equalizing
Float Pressure Relief Valve
Relief Connection Fixed Liquid Dip
Part Container Service Filling Gauge
Valve UL Listed Flange Level Vent Valve Tube UL Flow Ready To Go™
Number* Connection Connection Connection Part Pipe-Away
Height Size Closing Length Setting Capacity
Opening Number Adapter
Flow SCFM
G8475RL Standard
Plugged
DG8475RL #72 Low Emission 3131-10
6¾” 1¼” 4200 CFH Fits M3131G 2020 SCFM, air
PG8475RL 2½” F. POL 1¾” Standard 250 (1" F.NPT)
M. @ 100 “JUNIOR” 30”* Yes
F. NPT (CGA 510) M. ACME PSIG
DP8475RL ACME PSIG size #72 Low Emission

3132-10
G8475RLW 8½” Standard MV3132G 3995 SCFM, air Plugged
(1¼" F.NPT)

*Dip tube not installed, may be cut by customer to desired length.

C6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
ASME Multivalve® Assemblies ® for Vapor Withdrawal
8593AL

Application
These Multivalve® assemblies provide vapor withdrawal and filling
of ASME containers. A separate pressure relief valve is required in
addition to this valve. The MultiBonnet® assembly is standard on
this valve.

Features
• Combines low emission double back check filler valve, vapor
equalizing valve, service valve, fixed liquid level and a plugged
pressure gauge opening.

• Double back check filler valve is low emission, 2.13cc at


disconnection with no reduction in fill rates.

• Includes plugged, ¼” F. NPT gauge boss.

• “Y” shape configuration allows for ease of operation with all valves
and gauges easily accessible at all times.

• Large 21⁄16” hex wrenching boss on center column provides ease


of installation in tank coupling.

• MultiBonnet® assembly allows quick and easy repair of bonnet.

Materials 8593AL
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Valve Stem.............................................................................. Brass
O-Ring.................................................................... Resilient Rubber
¾” NPT THD. for standard
C
Seat Disc (shut-off valve)........................................................ Nylon
Seat Discs (other)................................................... Resilient Rubber weight baffle pipe length
to suit tank.
(Furnished by customer)
6”
Approx

10
REGO

YEAR
WARRANTY

¼ NPT steel plug


installed
Liquid Filling Rates
Approximate Filling Rate 16”
Liquid Flow, GPM
3¼” Approx.
Pressure Drop Across Valve
3¼” Approx.
10 25 50 100
Part Number PSIG PSIG PSIG PSIG
8593AL16.0 42 72 98 125

Ordering Information
Vapor Equalizing Connection Fixed Liquid Dip
Container Service Filling Level Vent Tube For Use In Containers w/
Part Number Connection Connection Connection Connection Size UL Listed Closing Flow Valve Style Length Surface Area Up To:
1½” F. POL 1¾” 1¼”
8593AL16.0 4200 CFH at 100 PSIG Knurled 16”* **
M. NPT (CGA 510) M. ACME M. ACME
*Dip tube not installed, may be cut by customer to desired length.
**Since these Multivalve® assemblies have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C7
DOT Multivalve® Assemblies for Liquid Withdrawal
8555DL

Application
These Multivalve® assemblies permit liquid withdrawal from DOT
cylinders with up to 100 lbs. propane capacity. They eliminate
unnecessary cylinder handling when servicing high volume loads
and allow on-site filling into the vapor space without interrupting gas
service.

Features
• Incorporates service valve, high capacity filler valve with integral
back check, fixed liquid level gauge, liquid withdrawal with excess
flow check and pressure relief valve in one single unit.

• CGA 555 service connection minimizes accidental connection to


vapor service systems.

• Furnished with 44” long, ½” O.D. brass liquid withdrawal tube.

• Liquid withdrawal tube incorporates a ball check excess flow valve


that opens by allowing vapor, not liquid, to equalize pressure.

• 11
⁄8” wrenching flats.

2⅝”
Approx.

Materials
Body............................................................................ Forged Brass
Handwheel......................................................... Aluminum Die Cast
Valve Stems............................................................................. Brass
O-Rings.................................................................. Resilient Rubber
Seat Disc (shut-off valve)........................................................ Nylon 4½”
Approx.
Seat Disc (others)................................................... Resilient Rubber
C Relief Spring.............................................................. Stainless Steel

10
REGO

YEAR
WARRANTY
11.6”
Approx.

44”
8555DL Approx.

Liquid Filling Rates


Approximate Filling Rate
Liquid Flow, GPM
Pressure Drop Across Valve
Part 10 25 50 100
Number PSIG PSIG PSIG PSIG
****8555DL11.6 8 23 34 42

Ordering Information
For Use In
Fixed Liquid Dip Tube Liquid Pressure Cylinders w/ Liquid Closing
Container Service Filling Level Vent Length w/ Withdrawal Tube Relief Valve Propane Capacity Flow
Part Number Connection Connection Connection Valve Deflector Length Setting Up To: (LP-Gas)***
8555DL11.6 Standard
¾” CGA 1¾” 375
#72 Low 11.6” 44” 100 lbs. ** 1.7 GPM
D8555DL11.6 M. NGT 555* M. ACME PSIG
Emission
* Use adapter 12982 to connect to pipe threads.
** Per CGA Pamphlet S-1.1.
*** To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use.

C8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
DOT & ASME Multivalve® Assemblies for Vapor Withdrawal
6555R, 8555D and 8555R Series

Application
These Multivalve® assemblies permit vapor withdrawal. They allow
for container filling without interrupting gas service.

The 6555R Series is designed for ASME containers with up to 25 ft²


surface area or 60 gallons water capacity. 4⅜”
Approx.
The 8555D and 8555R Series are designed for DOT cylinders with up
to 200 lbs. propane capacity.

Features
• Incorporates service valve, high capacity filler valve with integral
back-check, fixed liquid level gauge and pressure relief valve in
one single unit.

• Filler Valve is high capacity with integral back check.

• Heavy duty O-ring stem seal provides positive leak proof seal.
8555R Dip Tube
• Tapered nylon shut-off seat disc in fully confined seat ensures Length
easy, leak-free, positive shut-off. Approx.

• 1⅛” wrenching flats.

10
REGO
• The MultiBonnet® assembly option allows quick and easy repair
of bonnet.
3” Approx.
YEAR
for “R” Models
WARRANTY 2⅝” Approx.
for “D” Models

C
Materials
Body............................................................................ Forged Brass Liquid Filling Rates
Handwheel......................................................... Aluminum Die Cast
Approximate Filling Rate
Valve Stems............................................................................. Brass
Liquid Flow, GPM
O-Rings.................................................................. Resilient Rubber
Seat Disc (shut-off valve)........................................................ Nylon Pressure Drop Across Valve
Seat Disc (others)................................................... Resilient Rubber Part 10 25 50 100
Relief Spring.............................................................. Stainless Steel Number PSIG PSIG PSIG PSIG
**6555D Series
**6555R Series
8 23 34 42
**8555D Series
**8555R Series

Ordering Information
For Use In Pressure Relief Valve
Containers Dip Tube Fixed Liquid Flow Capacity*
with Size Up Length w/ Container Service Filling Level Vent
Part Number Bonnet Style Application To: Deflector Connection Connection Connection Valve Setting UL Listing ASME
6555R10.6 10.6
6555R11.6 2
25 ft surface 11.6 Standard
6555R12.0 12.0 700
MultiBonnet® ASME area or 60 250 793
SCFM,
D6555R10.6 assembly Containers gallons water 10.6 PSIG SCFM, air
#72 Low air
D6555R11.6 capacity 11.6
Emission
D6555R12.0 12.0
8555D10.6 10.6 ¾” F. POL 1¾”
Standard
8555D11.6 11.6 M. NGT (CGA 510) M. ACME
Standard
D8555D10.6 10.6 #72 Low
D8555D11.6 DOT 200 lbs. 11.6 Emission 375
n/a n/a
8555R10.6 Cylinders Propane** 10.6 PSIG
Standard
8555R11.6 MultiBonnet® 11.6
D8555R10.6 assembly 10.6 #72 Low
D8555R11.6 11.6 Emission
*Per CGA Pamphlet S-1.1.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C9
DOT and ASME Multivalve® Assemblies for Vapor Withdrawal 6532, 6533,
6542, 6543 Series and PT6542, PT6543 Series with Presto-Tap® Valve

Application
These Multivalve® assemblies permit vapor withdrawal from ASME
containers up to 50 sq. ft. surface area and DOT containers up to
420 lbs. propane capacity. They allow on-site cylinder filling without
interrupting gas service.

Features 6542 and 6543


• Incorporates high capacity filler valve with double back checks,
5½”
service valve, fixed liquid level gauge, pressure relief valve and Approx.
built-in baffle tube into one compact unit.
• Higher filling capacity is combined with back check protection by
placing the secondary back check at the bottom of the baffle tube,
creating a larger flow area through the body. 513/16” 2¾” Approx
• Pre-drilled hole in 1¼” wrenching flat accepts a drive screw for Approx. on “A”
attaching relief cap and chain. Models
3¼” Approx.

10
• With the Service Valve closed the Pressure Test / Presto-Tap® on “R” REGO
port is isolated from the container. This will allow a high pressure Dip Tube Models
leak test to be conducted without disconnecting the pigtail from Length
the service valve. For more information, see page C12 on this feature.
Features 6532 and 6533 YEAR PT6543R
• Similar but smaller than the 6542 and 6543, these are generally WARRANTY
used for replacement on existing containers with ¾ ” NGT Liquid Filling Rates
openings.
Approximate Filling Rate -- Liquid Flow, GPM
• Secondary back check placed in the body of the valve to help
minimize reverse flow in the event the upper back check shears Pressure Drop Across Valve
off or requires replacement. Part Number 10 PSIG 25 PSIG 50 PSIG 100 PSIG
• The MultiBonnet® assembly option allows quick and easy repair
6532A12.0/6532R12.0 11 16 23 28
of bonnet.
6542A12.0/6542R12.0 23 32 46 57
Materials
Body............................................................................ Forged Brass 6533A10.5/6533R10.5
11 16 23 28
Handwheel......................................................... Aluminum Die Cast 6533A11.7/6533R11.7
C Valve Stems............................................................................. Brass 6543A11.1/6543R11.1
O-Rings.................................................................. Resilient Rubber
6543A11.7/6543R11.7
Seat Disc (shut-off valve)........................................................ Nylon
Seat Disc (others)................................................... Resilient Rubber PT6542A12.0/6542R12.0 23 32 46 57
Relief Spring.............................................................. Stainless Steel PT6543A11.1/6543R11.1
PT6543A11.7/6543R11.7
Ordering Information
For Use In UL Flow
Fixed Dip Tube Pressure Cylinders Capacity @
Liquid Length Relief w/Propane 120% of set
Container Service Filling Level Vent with Valve Capacity Up pressure
Part Number Bonnet Style Application Connection Connection Connection Valve Style Deflector Setting To:** SCFM (air) Ready To Go™
6532A12.0 Standard
MultiBonnet® ¾” M. NGT 1180
6532R12.0 Plugged
assembly
6542A12.0 250
ASME* 12.0” -
Standard PSIG
PT6542A12.0 Yes
1” M. NGT 1530
6542R12.0 MultiBonnet® Plugged
PT6542R12.0 assembly Yes
6533A10.5 Standard
MultiBonnet® 10.5”
6533R10.5
assembly
¾” M. NGT
6533A11.7 Standard F. POL 1¾” Plugged
Knurled
(CGA 510) M. ACME
MultiBonnet® 11.7”
6533R11.7
assembly
6543A11.1
Standard 375 420 lbs.
PT6543A11.1 DOT - Yes
PSIG Propane
11.1”
6543R11.1 MultiBonnet® Plugged
PT6543R11.1 assembly Yes
1” M. NGT
6543A11.7 Plugged
Standard
PT6543A11.7 Yes
11.7”
6543R11.7 MultiBonnet® Plugged
PT6543R11.7 assembly Yes

** Per CGA Pamphlet S-1.1.

C10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
ASME Multivalve ® Assemblies for Vapor Withdrawal
7556R

Application
These compact Multivalve® assemblies are especially suited for
vapor withdrawal of ASME containers where compact groupings of
components are necessary. Separate filler valves and pressure relief
valves are required.

Features
• Combines service valve, vapor equalizing valve with excess flow,
fixed liquid level gauge and plugged pressure gauge opening in
one unit.

• Rugged, 1” wrenching boss on center column minimizes possible


damage during installation.

• Low profile design extends only 3” above the container boss,


allowing use of smaller domes. PT7556R

• “Y” shape configuration allows for ease of operation with all valves PT7556R version with the service valve closed the pressure test port
and gauges easily accessible at all times. will be isolated from the container. This will allow a high-pressure
leak test to be conducted without disconnecting the pigtail from the
• Designed for installation of a ⅛” M.NPT pressure gauge
service valve.
or pressure gauge connection. The pressure test port will
communicate to the downstream side of the service valve. 7556R Series with ⅛” FNPT pressure test port.
• MultiBonnet® assembly allows quick and easy repair of bonnet.

• PT7556R version: With the service valve closed the pressure test/
Presto-Tap® port is isolated from the container. This will allow a
high pressure leak test to be conducted without disconnecting the
pigtail from the service valve. For more information see page C12.

Materials ⅛” F.NPT Pressure Test Port is isolated from the container


Body............................................................................ Forged Brass when the service valve is closed. C
Handwheel......................................................... Aluminum Die Cast
Valve Stems............................................................................. Brass
O-Rings.................................................................. Resilient Rubber
Seat Disc (shut-off valve)........................................................ Nylon
Seat Disc (others)................................................... Resilient Rubber
31/8”

10
REGO

YEAR
WARRANTY

PT7556 R Multivalve® Assembly


Especially suited for vapor withdrawal of ASME containers where
compact groups of components are necessary. Separate filler valves
and pressure relief valves are required

Ordering Information
Vapor Equalization Connection

Container Service Fixed Liquid Level Dip Tube


Part Number Connection Connection Connection Size UL Listed Closing Flow Vent Valve Length Ready to Go™
7556R12.0 Plugged
Standard
PT7556R12.0 Yes
¾” M. NGT F. POL (CGA 510) 1¼” M. ACME 4200 CFH @ 100 PSIG 12”**
D7556R12.0 Plugged
#72 Low Emission
DPT7556R12.0 Yes
* Since these Multivalve® assemblies have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
** Other tube lengths available.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C11
DOT and ASME Multivalve® Assemblies Info Page

Patented LDS200RV Design Features

y t o G o Va lv
ad es
Re
UV Resistant Save Time
Save Money
Cap Reduce Emissions

Nitrile ™

O-Ring
®

Valve Body
Core Viton
Seat
US Patent # 6,209,562

The Patented Presto-Tap® LDS2000RV pressure fitting is designed to be


UL Label one of the most cost efficient and simplest methods to quickly and easily
perform system pressure checks.
Brass Body
54 orifice
• Patented & UL Listed.
E LOW A
G B MB
IN I C I ENT
A D SUFF VAP I E
IN O

AT RE

N I ZA
S

T
R
E
INDI C C

TEM N
TI

TI O
STA

P
• Provides instant ROI after only one use. AM .° F

• Will reduce fugitive emissions by up to 90%.


BI ENT T EM P

• Can be installed into valves, regulators & appliances.


• Eliminates the need to break the system to perform a leak test.
Presto-Tap® Valve System Leak Test Procedure
The Presto-Tap® fitting installed into the test port located on the downstream side of the service valve is designed to allow quick and easy access
when performing a system leak test. It eliminates the need to break the system to install expensive test block apparatus. The following PT9102R
series service valve shown here, illustrates how to use the Presto-Tap® fitting to perform a high-pressure system leak test. This same procedure
applies to the PT7556R, PG8475, PT6542 and PT6543 series valves not shown here that carry the same feature.

E LOW A
G B MB
IN I C I ENT
A D SUFF VAP I E
IN O
AT RE

N I ZA

S
T
R
E
INDI C C

TEM N
TI

TI O
STA

C AM
BI ENT T EM P
.° F

1 2 3
Remove Gas Tight Cap from pressure fitting. Attach 300 LB Gauge to pressure fitting. Once the system has been leak tested
Perform System Leak Test Per NFPA 58 - successfully simply remove the 300 LB gauge
Your Company Policy. and replace and snug the Gas Tight Cap.
E LOW A
G B MB
IN I C I ENT
A D SUFF VAP I E
IN O
AT RE

N I ZA

S
T
R
E
INDI C C

TEM N
TI

TI O
STA

AM .° F
BI ENT T EM P

PG8475RL Series PT7556 Series PT9102R Series PT6543 Series


PT6542 Series

Only trained qualified personnel should perform leak testing. As for any LP-Gas installation, service or repair it is required that time be
taken to ensure safety and all federal, state and local regulations are met.

C12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Adhesive Warning Label
903-500

The following warning information, Part Number 903-500, is included Part


with each shipment of Multivalve® assemblies to the first purchaser Number
of the product from the factory.
903-500 Adhesive Label Primarily for Cylinder and Service Valves

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from RegO and
Authorized Product Distributors.

DANGER READ THIS FIRST WARNING


LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Make sure you are thoroughly trained before you attempt any valve installation, maintenance or repair.
Improper conditions or procedures can cause accidents resulting in property damage and personal injury.
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &
Maintenance” and RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and
“LP-Gas Filler and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve
sections of the L-500 & L-102 Catalogs. Follow their recommendations.
Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is
essential in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed
to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper
handling procedures. Refresher training shall be provided at least every three years and shall be documented.”
Make sure this valve is the proper one for this installation. Avoid misusing LP-Gas equipment.
Apply thread joint compound compatible with LP-Gas on valve external threads only. Make sure compound
never comes into contact with other parts of the valve.
Install valves by applying force to wrenching flats only.
Tighten pipe threads approximately 1 to 1½ turns beyond the hand-tight insertion point using a wrench which
avoids damage to other valve parts.
Check for damage and proper operation after valve installation. Check that the valve is clean and free
of foreign material.
Check container-valve connection with a non-corrosive leak detection solution before filling with LP-Gas.
Purge container before filling with LP-Gas (refer to the RegO LP-Gas Serviceman’s Manual for recommended
procedure).
Test excess flow check valve for proper operation before placing into service. See NPGA Bulletin 113 for
recommended procedure.
Check outlet connection make-up for leaks with a non-corrosive leak detection solution when placing
into service.
RegO Filler Valves: To prevent damage to the internal checks when it is necessary to utilize an unloading
adapter, use ONLY RegO 3119A, 3120 and 3121 Unloading Adapters with RegO Filler Valves. Carefully
C
follow the instructions supplied with these unloading adapters.
If container is not being placed into service at the present time, insert plug or cap onto the outlet connection.
In selecting a label for posting at the installation site, consider RegO part number 901-400 or 903-400 along
with your own, NPGA’s and others.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment.
See RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and “LP-Gas Filler
and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve sections of the
L-500 & L-102 Catalogs.

RegO requests that this information be forwarded to your customers. Additional copies are available from
RegO and your authorized RegO Distributor.
Printed in USA 09A-0910-0686
PRODUCTS
R Part number 903-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

903-500

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO C13
C

C14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section D
Pressure Relief Valves
and Relief Valve Manifolds D D

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
D warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

D2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. D
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D3
Safety Warning — LP-Gas Pressure Relief Valves

Purpose

In its continuing quest for safety, RegO is publishing safety warning


bulletins explaining the hazards associated with the use, misuse

! WARNING
and aging of RegO Products. LP-Gas dealer managers and service
personnel must realize that the failure to exercise the utmost care
and attention in the installation, inspection and maintenance of these
products can result in personal injury and property damage.

The National Fire Protection Association NFPA 58 Liquefied


Petroleum Gas Code - 2020 Edition states in Section 4.4 Qualification
of Personnel; ”Persons whose duties fall within the scope of this code
shall be provided with training that is consistent with the scope of What You Must Do:
their job activities and that includes proper handling and emergency
response procedures... Refresher training shall be provided at least • Read This Entire Warning
every 3 years, initial and subsequent training shall be documented”.
These “RegO Safety Warnings” may be useful in training new
employees and reminding older employees of hazards that can • Install Properly
occur. It is recommended that all employees complete the Propane
Education Research Council’s Certified Employee Training Program. • Inspect Regularly
This Warning Bulletin should be provided to all purchasers of RegO
and all personnel using or servicing these products. Additional copies
are available from RegO and your Authorized RegO Distributor.

Scope

This bulletin applies to pressure relief valves installed on stationary, Warnings should be as brief as possible. If there is a simple warning,
D portable and cargo containers and piping systems utilized with these
containers. This bulletin is not intended to be an exhaustive treatment
it is:

of this subject and does not cover all safety practices that should Inspect pressure relief valves regularly. Replace unsafe or suspect
be followed in the installation and maintenance of LP-Gas systems. valves immediately. Use common sense.
Each LP-Gas employee should be provided with a copy of NPGA
Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspection and
Maintenance” as well as the NPGA “LP-Gas Training Guidebooks”
relating to this subject.

D4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Inspect Regularly

4. Physical damage. Ice accumulations and improper installation could


A pressure relief valve discharges when some extraordinary cause mechanical damage. IF THERE ARE ANY INDICATIONS OF
circumstance causes an over pressure condition in
DAMAGE, REPLACE THE VALVE.
the container. If a pressure relief valve is known to have
discharged, the relief valve, as well as the entire system,
5. Tampering or readjustment. Pressure relief valves are
should be immediately and thoroughly inspected to determine
factory set to discharge at specified pressures. IF THERE ARE
the reason for the discharge. In the case of discharge due to
ANY INDICATIONS OF TAMPERING OR READJUSTMENT,
fire, the valve should be removed from service and replaced.
REPLACE THE VALVE.

Relief valves should be inspected each time the container is 6. Seat leakage. Check for leaks in the seating area using a
filled but no less than once a year. If there is any doubt about noncorrosive leak detection solution. REPLACE THE VALVE IF
the condition of the valve, it must be replaced. THERE IS ANY INDICATION OF LEAKAGE. Never force a relief
valve closed and continue to leave it in service. This could result
Eye protection must be worn when performing inspection on relief in damage to the valve and possible rupture of the container or
valves under pressure. Never look directly into a relief valve under piping on which the valve is installed.
pressure or place any part of your body where the relief valve
discharge could impact it. In some cases a flashlight and a small 7. Corrosion and contamination. REPLACE THE VALVE
mirror are suggested to assist when making visual inspections. IF THERE ARE ANY SIGNS OF CORROSION OR
CONTAMINATION ON THE VALVE.

To Properly Inspect A Pressure Relief Valve, Check For: 8. Moisture, foreign particles or contaminants in the valve.Foreign
1. A rain cap. Check protective cap located in valve or at end of material such as paint, tar or ice in relief valve parts can impair
pipeaway for a secure fit. Protective caps help protect the relief the proper functioning of the valves. Grease placed in the valve
valve against possible malfunction caused by rain, sleet, snow, body may harden over time or collect contaminants, thereby
ice, sand, dirt, pebbles, insects, other debris and contamination. impairing the proper operation of the relief valve. DO NOT PLACE
REPLACE DAMAGED OR MISSING CAPS AT ONCE AND GREASE IN THE VALVE BODY. REPLACE THE VALVE IF
KEEP A CAP IN PLACE AT ALL TIMES. THERE ARE ANY INDICATIONS OF MOISTURE OR FOREIGN
MATTER IN THE VALVE.
2. Open weep holes. Dirt, ice, paint and other foreign particles
can prevent proper drainage from the valve body. IF THE WEEP 9. Corrosion or leakage at container connection. Check container
to valve connection with a non-corrosive leak detection solution.
HOLES CANNOT BE CLEARED, REPLACE THE VALVE.
REPLACE THE VALVE IF THERE IS ANY INDICATION OF
D
3. Deterioration and corrosion on relief valve spring. Exposure CORROSION OR LEAKAGE AT THE CONNECTION BETWEEN
to high concentrations of water, salt, industrial pollutants, THE VALVE AND CONTAINER.
chemicals and roadway contaminants could cause metal parts
to fail. IF THE COATING ON THE RELIEF VALVE SPRING CAUTION: Never plug the outlet of a pressure relief valve. Any device
IS CRACKED OR CHIPPED, REPLACE THE VALVE. used to stop the flow of a properly operating pressure relief valve that
is venting an overfilled or overpressurized container - raises serious
safety concerns!

Replace Pressure Relief Valves In 10 Years Or Less


WARNING: Under normal conditions, the useful safe service
The safe useful life of pressure relief valves can vary greatly depending life of a pressure relief valve is 10 years from the original date
on the environment in which they live. of manufacture. However, the safe useful life of the valve
may be shortened and replacement required in less than 10
Relief valves are required to function under widely varying conditions. years depending on the environment in which the valve lives.
Corrosion, aging of the resilient seat disc and friction all proceed at Inspection and maintenance of pressure relief valves is very
different rates depending upon the nature of the specific environment important. Failure to properly inspect and maintain pressure
and application. Gas impurities, product misuse and improper relief valves could result in personal injuries or property damage.
installations can shorten the safe life of a relief valve.
For Additional Information Read:
Predicting the safe useful life of a relief valve obviously is not an
1. CGA Pamphlet S-1.1 Pressure Relief Standards - Cylinders, Section 9.1.1.
exact science. The conditions to which the valve is subjected will vary
widely and will determine its useful life. In matters of this kind, only 2. RegO Catalog L-500.
basic guidelines can be suggested. For example, the Compressed
Gas Association Pamphlet S-1.1 Pressure Relief Device Standards — 3. RegO Warning # 8545-500.
Cylinders, section 9.1.1 requires all cylinders used in industrial motor
fuel service to have the cylinder’s pressure relief valves replaced by new 4. NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspection
or unused relief valves within twelve years of the date of manufacture and Maintenance” and “LP-Gas Training Guidebooks”.
of cylinder and within each ten years thereafter. The LP-Gas dealer
5. NFPA # 58, “Storage and Handling of Liquefied Petroleum Gases”.
must observe and determine the safe useful life of relief valves in his
territory. The valve manufacturer can only make recommendations for 6. NFPA # 59, “LP-Gases at Utility Gas Plants”.
the continuing safety of the industry.
7. ANSI K61.1 Safety Requirements for Storage and Handling of
Anhydrous Ammonia.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D5
RegO Pressure Relief Valves

Requirements for Pressure Relief Valves The reasons for this are two-fold:
Every container used for storing or hauling LP-Gas and anhydrous If the relief valve is called upon to open, the resulting discharge
ammonia must be protected by a pressure relief valve. These valves must produces an increased vaporization of the product in the container
guard against the development of hazardous conditions which might be with the result that the liquid cools to a certain extent and the
created by any of the following: vapor pressure drops. A reading taken at this time would obviously
not indicate what the pressure was when the relief valve opened.
Hydrostatic pressures due to overfilling or the trapping of liquid
between two points.
The pressure gauges usually on most containers provide
somewhat approximate readings and are not intended to provide
High pressures resulting from exposure of the container to
excessive external heat. an indication of pressure sufficiently accurate to judge the setting
of the relief valve.
High pressures due to the use of incorrect fuel.

High pressures due to improper purging of the container.


Repair and Testing

Consult NFPA Pamphlet #58 for LP-Gas and ANSI #K61.1 for RegO Pressure Relief Valves are tested and listed by
anhydrous ammonia, and/or any applicable regulations governing Underwriters Laboratories, Inc., in accordance with NFPA
the application and use of pressure relief valves.
Pamphlet #58. Construction and performance of RegO
Pressure Relief Valves are constantly checked at the factory
Operation of Pressure Relief Valves
by U.L. inspectors. Therefore, testing of RegO Pressure
Pressure relief valves are set and sealed by the manufacturer to function
at a specific “start-to-discharge” pressure in accordance with regulations.
Relief Valves in the field is not necessary.
This set pressure, marked on the relief valve, depends on the design
requirement of the container to be protected by the relief valve. If the Any pressure relief valve which shows evidence of leakage, other
container pressure reaches the start-to-discharge pressure, the relief valve improper operation or is suspect as to its performance must be
will open a slight amount as the seat disc begins to move slightly away replaced immediately using approved procedures.
from the seat. If the pressure continues to rise despite the initial discharge
through the relief valve, the seat disc will move to a full open position with
a sudden “pop”. This sharp popping sound is from which the term “pop- Pipe-Away Adapters
action” is derived.
Pipe-away adapters are available for most RegO Pressure Relief
D Whether the relief valve opens a slight amount or pops wide open, it will Valves, where it is required or desirable to pipe the discharge above
start to close if the pressure in the container diminishes. After the pressure or away from the container. Each adapter is designed to sever if
has decreased sufficiently, the relief valve spring will force the seat disc excessive stress is applied to the vent piping – thus leaving the relief
against the seat tightly enough to prevent any further escape of product. valve fully operative.
The pressure at which the valve closes tightly is referred to as the “re-seal”
or “blow-down” pressure. Generally, the re-seal pressure will be lower than Weep hole deflectors are available on larger relief valves. These
the start-to-discharge pressure.The re-seal pressure can be, and in most deflectors provide protection against flame impinging on adjacent
cases is, adversely affected by the presence of dirt, rust, scale or other containers which could occur from ignition of LP-Gas escaping
foreign particles lodging between the seat and disc. They interfere with through the relief valve drain hole when the valve is discharging.
the proper mating of the seat and disc and the pressure in the container
will usually have to decrease to a lower pressure before the spring force Selection of RegO Pressure Relief Valves For ASME Containers
embeds foreign particles into the resilient seat disc material and seals
leak-tight. The degree by which the presence of dirt decreases the re-seal The rate of discharge required for a given container is determined by
pressure, is, of course, dependent on the size of the interfering particles. the calculation of the surface area of the container as shown in “Chart
A” for LP-Gas and “Chart B” for anhydrous ammonia. See page D9.
Once particles have been trapped between the disc and seat, the start-
to-discharge pressure is also affected. For example, the pressure relief Setting - The set pressure of a pressure relief valve depends upon
valve will start-to-discharge at some pressure lower than its original start- the design pressure of the container. Refer to NFPA Pamphlet #58
to-discharge pressure. Again, the pressure at which the valve will start to for more information.
discharge is dependent on the size of the foreign particles.
Selection of RegO Pressure Relief Valves for DOT Containers
In the case of a pressure relief valve that has opened very slightly due
to a pressure beyond its start-to-discharge setting, the chances of To determine the proper relief valve required for a given DOT
foreign material lodging between the seat and disc is negligible although container, refer to the information shown with each pressure relief
the possibility is always present. If the relief valve continues to leak at valve in the catalog. This information will give the maximum size
pressures below its start-to-discharge setting it must be replaced. (pounds water capacity) DOT container for which the relief valve has
been approved.
Relief valves which have “popped” wide open must also be
checked for foreign material lodged between the seat and disc, Setting - The standard relief valve setting for use on DOT cylinders
as well as for proper reseating of the seat and disc. Continued is 375 PSIG.
leakage at pressures below the start-to-discharge setting indicate
the relief valve must be replaced.

The pressure at which a pressure relief valve will start to


discharge should never be judged by the reading of the pressure
gauge normally furnished on the container.

D6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
RegO Pressure Relief Valves

Ordering RegO Pressure Relief Valves Part Number Explanation

When ordering RegO Pressure Relief Valves, be sure you are certain that Products carrying an “A” or “AA” prefix contain no brass parts and are
it will sufficiently protect the container as specified in the Foreword section, suitable for NH3. Hydrostatic relief valves carrying an “SS” prefix are
NFPA Pamphlet #58 and any other applicable standards or specifications. of stainless steel construction and are suitable for use with NH3. The
products are also suitable for use with LP-Gas service except relief valves
All adapters, protective caps and deflectors must be ordered separately, carrying an “AA” prefix. These are of partial aluminum construction and are
unless specified otherwise. listed by U.L. for NH3 service only.

Safety Information - Relief Valves Don’t Last Forever

RegO Relief Valve for lift truck containers

The internal spring is protected from external


contamination but the other external parts must be
protected with a cap. Circular rubber seat disc ring
seats on brass shoulder approximately 3⁄64” wide.

This article was prepared by the engineers of RegO products, after Relief valves, over the years, may not function properly in
D
technical consultation with valve manufacturers and other industry several ways:
sources. Its purpose is to alert and remind the LP-Gas industry of the
importance of proper maintenance of pressure relief valves. It applies most They may leak at pressures below the set pressure.
particularly to separate relief valves with emphasis on lift truck and motor
fuel containers where the hazards of contamination are greatest. They may open and fail to properly reseat.

They may open at higher than the set pressure.


Since the beginning of our industry, manufacturers of equipment
and distributors of LP-Gas have worked diligently to provide a safe These failures to function properly are due primarily to four
environment for employees and consumers. The history of the industry
“environmental’’ conditions:
testifies to the success of their efforts.
1. Corrosion of metal parts (particularly springs) which result in the
But the industry is now entering its sixth decade and equipment installed component parts failing to perform.
years ago is failing because of age. Every year, additional equipment will
fail unless it is replaced. Pressure relief valves are no exception. The valve 2. Deterioration of the synthetic rubber seat disc material.
manufacturers and LP-Gas dealers are naturally concerned about this
situation. 3. Clogging or “cementing” of the movable relief valve components
so that their movement is restricted.

4. Debris on the valve seat after the relief valve opens, effectively
preventing the valve from reseating.
Causes of Relief Valve Failure
A relief valve is designed to have a safe useful life of many years, Corrosion is caused by water, corrosive atmospheres of salt and industrial
but that life will vary greatly depending on the environment in which it pollutants, chemicals, and roadway contaminants. High concentrations
“lives.” To attempt to estimate the safe useful life of a relief valve and can attack the metal parts vigorously. No suitable metals are totally
the effect of environment on its performance, a brief discussion of the resistant to such corrosion.
materials used and the nature of its performance should be helpful.
Synthetic rubber and seat disc materials can also be attacked by
Relief valve bodies are generally made of brass or steel. Springs are made impurities in the gas and corrosive atmospheres, particularly those with
from various spring wires which are plated or painted, or made of stainless sulphur dioxide. There are no suitable rubber materials which resist all
steel. Valve seat discs are made of synthetic rubber compounds which contaminants.
will remain serviceable in an atmosphere of LP-Gas. Relief valve stems,
guides, etc. are generally made from brass or stainless steel. “Cementing” of relief valve parts has been caused by normal industrial
atmospheres containing particles of dirt, iron oxide, metal chips, etc.
combined with water, oil, or grease. Ice collecting in recessed valves could
cause relief valves to fail to open. Paint and tar in relief valves also cause
failure to function properly.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D7
Safety Information - Relief Valves

Debris on valve seats which prevents reseating can occur whenever Use of Protective Caps
the valve collects material in the relief valve opening which is not
blown out when the relief valve opens. Many of the problems that cause inoperative relief valves could
be prevented if proper protective caps were kept in place at all
Inspection of Relief Valves times.
Unfortunately many of the above problems may not be easily
observed because of the compact nature of some relief valve
designs. Collection of debris would be prevented. Contamination caused by
corrosive atmospheres would be reduced. Water collection in the
valves would be eliminated. Relief valves protected with caps from
A casual visual inspection of a relief valve may not necessarily the time of installation in the container would obviously have a much
disclose a potential hazard. On the other hand, a visual inspection longer safe useful life, but they still should be replaced at some time
will often disclose leakage, corrosion, damage, plugging and because of the gradual deterioration of the rubber seat disc due to
contamination. age alone.
If additional light is required, a flashlight should be used.
NFPA 58 requires that protective caps must be kept in place as
If there is any doubt about the condition of the valve, or if there a protective cover on some relief valves. This is a mandatory
is a suspicion that the valve has not been protected by a cap for requirement on several types of relief valves. The fact that use of
some time, it should be replaced before refilling the container. caps may make inspection more time consuming should not be
viewed as a reason for either not using the caps, or not making
required periodic inspections.

Eye protection must be used when examining relief valves under In the event a relief valve has been used without the required cap,
pressure. the relief valve should be thoroughly inspected and the required cap
placed on the relief valve. If damage is noted to the relief valve, it
Smaller Relief Valves should be replaced and the replacement valve should be capped.
The industry’s requirement for a small full-flow safety relief valve Relief valves with pipe-away adapters or deflectors used on lift truck
challenged design engineers some years ago: containers have been found choked with debris. Inspection of relief
valves with deflectors can only be accomplished by removing the
The valve must be leakproof before operating and must reseat deflector.
leakproof each time after each operation. The only known satisfactory
seat disc materials to accomplish this have been special synthetic Similarly, larger relief valves with vent stacks have been found
D rubber compounds. choked with debris and water. Valves have failed because springs
rusted through. The weep hole was plugged. It was obvious that the
● Valve discharge settings are relatively high and require high relief valves had not been inspected in many years. These conditions
spring loads to keep the valve closed. must be alleviated by periodic inspections and replacement of relief
valves as needed.
● Because of the small interior diameter of the valve, the round
metal seating area is small. Summary Recommendations
Predicting the safe useful life of a relief valve is obviously not an
All of these parameters may result in the development of a significant exact science. The conditions to which the valve is subjected will vary
indentation in the rubber seat disc after some years. The seat disc widely and will largely control its life. In matters of this kind, only basic
may have a tendency to cling to the metal seat. This may result in guidelines can be suggested. The LP-Gas dealer must observe and
the relief valve not opening at the set pressure as the seat disc ages. determine the safe useful life of relief valves in his territory. The valve
manufacturers can only make recommendations for the continuing
Tests have been conducted on small LP-Gas relief valves of all the safety of the industry:
U.S. valve manufacturers. Valves over 10 years old were removed
from service and tested to determine at what pressure the valves
1. Make sure proper protective caps are in place at all times. Do not
discharged. In many of the valves, the pressure required to open the
release a container for service or fill a container unless it has a
valve exceeded the set pressure.
protective cap in place.

Because of the critical importance of proper functioning of relief 2. Replace relief valves periodically, at least every 10 years. Every
valves, common sense and basic safety practice dictate that relief valve has the month and year of manufacture stamped on
small relief valves should be replaced in about 10 years.
the valve. This is most particularly true of small separate relief
valves.
Some larger relief valves on bulk storage tanks can be replaced with
rebuilt valves obtained from the manufacturers. Small relief valves 3. Carefully inspect valves each time before the container is filled.
cannot be rebuilt economically, thus, new valves are required. Most Replace valves showing any signs of contamination, corrosion,
LP-Gas dealers find it impractical and costly to test relief valves and damage, plugging, leakage, or any other problem. Eye protection
field repairing of relief valves is not sanctioned by the manufacturers, must be used when examining relief valves under pressure.
Underwriter’s Laboratories, or ASME.

D8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Minimum Required Rate of Discharge for Pressure Relief Valves
Used on ASME Containers

Chart A — Minimum Required Rate of Discharge for LP-Gas Pressure Relief Valves Used on
ASME Containers Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-to-discharge
pressure for pressure relief valves to be used on containers other than those constructed in accordance with Interstate
From NFPA #58 2020, Chapter 5.9.2. Commerce Commission specification.
Surface Surface Surface Surface Surface Surface
Surface Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate
Area Sq. Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air
20 or less 626 85 2050 150 3260 230 4630 360 6690 850 13540 1500 21570
25 751 90 2150 155 3350 240 4800 370 6840 900 14190 1550 22160
30 872 95 2240 160 3440 250 4960 380 7000 950 14830 1600 22740
35 990 100 2340 165 3530 260 5130 390 7150 1000 15470 1650 23320
40 1100 105 2440 170 3620 270 5290 400 7300 1050 16100 1700 23900
45 1220 110 2530 175 3700 280 5450 450 8040 1100 16720 1750 24470
50 1330 115 2630 180 3790 290 5610 500 8760 1150 17350 1800 25050
55 1430 120 2720 185 3880 300 5760 550 9470 1200 17960 1850 25620
60 1540 125 2810 190 3960 310 5920 600 10170 1250 18570 1900 26180
65 1640 130 2900 195 4050 320 6080 650 10860 1300 19180 1950 26750
70 1750 135 2990 200 4130 330 6230 700 11550 1350 19780 2000 27310
75 1850 140 3080 210 4300 340 6390 750 12220 1400 20380
80 1950 145 3170 220 4470 350 6540 800 12880 1450 20980

Surface area =Total outside surface area of container in square feet. Flow Rate SCFM Air = Required flow capacity in cubic feet per minute
When the surface area is not stamped on the name plate or when the of air at standard conditions, 60ºF. and atmospheric pressure (14.7 psia).
marking is not legible, the area can be calculated by using one of the The rate of discharge may be interpolated for intermediate values of
following formulas: surface area. For containers with total outside surface area greater
1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = than 2000 square feet, the required flow rate can be calculated using
overall length (ft.) x outside diameter (ft.) x 3.1416. the formula, Flow Rate-SCFM Air = 53.632 A0.82 Where A = total outside
surface area of the container in square feet.
2. Cylindrical container with semi-ellipsoidal heads. Area (in sq. ft.) =
(overall length (ft.) + .3 outside diameter (ft.)) x outside diameter (ft.) x
3.1416. D
3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x
3.1416.

Chart B — Minimum Required Rate of Discharge for Anhydrous Ammonia Pressure Relief
Valves Used on ASME Containers
Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-
From ANSI K61.1-1981, Appendix A (1981). to-discharge pressure for pressure relief valves to be used on containers other than those constructed in
accordance with United States Department of Transportation cylinder specifications.
Surface Surface Surface Surface Flow Surface Surface
Surface Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Flow Rate Area Sq. Rate Area Sq. Flow Rate Area Sq. Flow Rate
Area Sq. Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air Ft. SCFM Air
20 258 95 925 170 1500 290 2320 600 4200 1350 8160 2100 11720
25 310 100 965 175 1530 300 2380 650 4480 1400 8410 2150 11950
30 360 105 1010 180 1570 310 2450 700 4760 1450 8650 2200 12180
35 408 110 1050 185 1600 320 2510 750 5040 1500 8900 2250 12400
40 455 115 1090 190 1640 330 2570 800 5300 1550 9140 2300 12630
45 501 120 1120 195 1670 340 2640 850 5590 1600 9380 2350 12850
50 547 125 1160 200 1710 350 2700 900 5850 1650 9620 2400 13080
55 591 130 1200 210 1780 360 2760 950 6120 1700 9860 2450 13300
60 635 135 1240 220 1850 370 2830 1000 6380 1750 10090 2500 13520
65 678 140 1280 230 1920 380 2890 1050 6640 1800 10330
70 720 145 1310 240 1980 390 2950 1100 6900 1850 10560
75 762 150 1350 250 2050 400 3010 1150 7160 1900 10800
80 804 155 1390 260 2120 450 3320 1200 7410 1950 11030
85 845 160 1420 270 2180 500 3620 1250 7660 2000 11260
90 885 165 1460 280 2250 550 3910 1300 7910 2050 11490
Surface area = Total outside surface area of container in square feet. Flow Rate SCFM Air = Required flow capacity in cubic feet per minute
When the surface area is not stamped on the name plate or when the of air at standard conditions, 60°F. and atmospheric pressure (14.7 psia).
marking is not legible, the area can be calculated by using one of the The rate of discharge may be interpolated for intermediate values of
following formulas: surface area. For containers with total outside surface area greater than
1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = overall 2,500 square feet, the required flow rate can be calculated using the
length (ft.) x outside diameter (ft.) x 3.1416. formula, Flow Rate-SCFM Air = 22.11 A0.82 where A = outside surface area
of the container in square feet.
2. Cylindrical container with other than hemispherical heads. Area (in sq.
ft.) = (overall length (ft.) + .3 outside diameter (ft.)) x outside diameter Conversion Factor
(ft.) x 3.1416. ft2 x 0.092 903 = m2
3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x SCFM x 0.028 317 = m3/min
3.1416. ft x 0.304 8 =m

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D9
RegO Pressure Relief Valves - Safe, Reliable, Durable Construction.
RegO Relief Valves are Made in America and Made to Last.
Choose RegO for your next decade of worry free operation.

“Pop-action” design
keeps product loss at Relief valve designed to
a minimum. automatically reseat firmly
after discharge.

Resilient seat disc provides


a “bubble-tight” seal.

Single piece cold-headed stem


D provides more accurate
positioning of working parts for
more consistent operation and
Longer spring size designed precise adjustment.
to minimize stress cracking
in service.

RegO® Relief Valves Multiport®, Delta Port™ and DuoPort™


Relief Valve Manifolds

Allows for relief valve removal and replacement


on a periodic basis without shutting down and
evacuating the container.

10
REGO REGO

100%
TESTED YEAR
WARRANTY

D10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pressure Relief Valve Inspection and Maintenance
Relief valves should be inspected each time the container is filled but no less than once a
year. If there is any doubt about the condition of the relief valve, it should be replaced.

Eye protection must be worn when performing


Major Factors that Impact the inspection on relief valves under pressure.
Service Life of Relief Valves Never look directly into a relief valve under
pressure or place any part of your body in the
relief valve’s discharge path.
• Water/Ice Accumulation

• Corrosion from environmental factors

• Dirt – Debris

• Physical Damage
Deterioration and corrosion
Check for deterioration and
• Normal Aging
corrosion on pressure relief
valve spring. Exposure to high
concentrations of water, salt,
industrial pollutants, chemicals
and roadway contaminates could
cause metal parts to fail. If the
coating on the spring is cracked
or chipped, replace the pressure D
relief valve.
Water Damage
Check protective cap located
in valve or at end of pipe away
for a secure fit. Protective
caps help protect the pressure
relief valve against possible
malfunction caused by rain, Open weep holes
sleet, snow, ice, sand, dirt, Dirt, ice, paint and other
pebbles, insects, other debris foreign particles can prevent
and contamination. Replace proper drainage from the
damaged or missing caps at valve body. If the weep holes
once and keep a cap in place cannot be cleared, replace
at all times. the pressure relief valve.

Physical damage. Ice accumulations and improper


installation could cause mechanical damage. IF THERE
Seat leakage ARE ANY INDICATIONS OF DAMAGE, REPLACE THE PRESSURE
Check for leaks in the seating RELIEF VALVE.
area using a non-corrosive leak
detection solution. Replace the
pressure relief valve if there Tampering or readjustment. Pressure relief valves are
are any indication of leakage. factory set to discharge at specified pressure. If there are
any indications of tampering or readjustment, replace the
pressure relief valve.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D11
“Pop-Action” Pressure Relief Valves

General Information Relief Valves in this catalog are only intended


The “Pop-Action” design permits the RegO Pressure Relief Valve to open slightly to relieve
for use in LP-Gas or anhydrous ammonia
moderately excessive pressure in the container. When pressure increases beyond a predetermined
service. Do not use any other service
point, the valve is designed to “pop” open to its full discharge capacity, reducing excess pressure
commodity. If you have an application other
quickly. This is a distinct advantage over ordinary valves which open gradually over their entire range,
than conventional LP-Gas or anhydrous
allowing excessive pressure to develop before the relief valve is fully open. All RegO internal, semi-
ammonia service, contact RegO before
internal, and external relief valves incorporate this “Pop-Action” design.
proceeding.

Fully Internal “Pop-Action” Pressure Relief Valves for Transports and


Bobtail Delivery Vehicles A8434 and A8436 Series
Application
Designed specifically for use as a primary relief valve on ASME cargo
tanks for transportation and bobtails with 2” and 3” F.NPT couplings.

Features
• Low profile design ensures maximum protection against shearing
or distortion.

• All functioning parts are located below the level of the container
connection to reduce the possibility of damage or tampering.

• Longer spring size designed to minimize stress cracking in


service.

• Use of two different materials for stem and guide minimizes the
possibility of stem seizure which may occur when similar materials
are used.
D • Internal octagonal wrenching broach ensures easy installation and
removal.

• ASME rated for use with LP-Gas and anhydrous ammonia A8434
and A8436 Series

• ASME rated for use with LP-Gas and Propylene VA8436 Series

Materials
Body.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
Stem.......................................................................... Stainless Steel
Stem Bushing............................................. 17 - 4PH Stainless Steel
Seat Disc (A8434 & A8436 series)......... Resilient Synthetic Rubber
Seat Disc (VA8436 series)........................................................ Viton
A8434-SERIES

10
REGO

YEAR
WARRANTY

Ordering Information
Flow Capacity SCFM/Air
Start To B C
Discharge A Overall Height Above UL
Part Setting Container Height Coupling (At 120% of ASME (At 120% Protective Cap Installation/
Number PSIG Connection (Approx.) (Approx.) Set Pressure) of Set Pressure) LP-Gas NH3 Propylene (Included) Removal Tool
A8434G 250 3456
2” M. NPTF 91/16” ½” 3700 A8434-11B A8434-40
A8434N 265 3659
Yes No
A8436G 250 9598
10210 Yes
A8436N 265 9839
3” M. NPTF 21.951” ¾” A8436-11B A8436-40
VA8436G 250 9596
- No Yes
VA8436N 265 9839
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.

D12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Fully Internal “Pop-Action” Pressure Relief Valves for
Motor Fuel Containers 8543, 8544 and 8546 Series

Application
8543 Series relief valves are designed for use as a primary relief
valve in larger ASME motor fuel containers such as on buses, RV’s,
trucks and construction equipment.

8544 Series relief valves are designed for use as a primary relief
valve in smaller ASME and DOT motor fuel containers such as on
tractors, lift trucks, cars and taxicabs.

Features
• Assure minimum product loss due to “pop-action” design.

• Recessed design minimizes possibility of damage and tampering.

• All are threaded to accept RegO Pipeaway Adapters that permit


the addition of a discharge hose or piping.
8546-11 ¾” 7544-11A 1” 7543-10 1¼”
• ASME rated for use with LP-Gas (except 8544K which meets
DOT requirements).

• Specify RegO Relief Valves on all your original equipment motor D


fuel container purchases for reliable performance.

C
Materials
Body........................................................................................ Brass
Spring (8543)............................................................. Stainless Steel
Spring (8544)................................................................ Coated Steel
Seat Disc................................................................ Resilient Rubber
A

D
B

10
REGO

YEAR
WARRANTY

8544

Ordering Information
Flow Capacity SCFM/Air****
A B C D Accessories
Start To Container Overall Height Above Hex UL ASME Protective
Container Discharge Connection Height Coupling Wrenching (At 120% of Set (At 120% of Set Cap Pipeaway
Part Number Type Setting PSIG M. NPT (Approx.) (Approx.) Section Pressure) Pressure) (Included) Adapter
8546G ¾” 4½” / ”
15 16 11/16” 723 651 11565-26 8546-11
8544G 250 1” 15/16” 1020 936 7544-41G 7544-11A*
57/16” ⅞”
8543G 1¼” 111/16” 1465 1400 3131-41 7543-10**
ASME
8546T ¾” 4½” / ”
15 16 11/16” 880 792 11565-26 8546-11
8544T 312 1” 15/16” 1282 1158 7544-41 7544-11A
8543T 1¼” 111/16” 1990 1731 3131-41 7543-10**
57/16” ⅞”
8544A375T NA 1384 7544-41G 7544-11A
DOT 375 1” 15/16”
8544K 1545*** NA 7544-41 7544-11A

* 1” M. NPT outlet connection.


** 1¼” M. NPT outlet connection.
*** Rating also applies to DOT requirements.
**** Flow rates shown are for bare relief valves. Adapters and pipeaway will reduce flow as discussed in the Foreword section.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D13
Fully Internal “Pop-Action” Pressure Relief Valve for DOT Fork Lift Cylinders
8545AK

Application
Designed specifically for use as a primary relief valve on forklift
cylinders, the 8545AK reduces the possibility of improper functioning
of the relief mechanism due to foreign material build up. All guides,
springs, stem and adjusting components are located inside the
cylinder - removed from the direct exposure of foreign materials and
debris from the atmosphere.

NFPA Pamphlet #58 requires that:


“All containers used in industrial truck (including forklift truck
cylinders) service shall have the container pressure relief valve
replaced by a new or unused valve within 12 years of the date of
manufacture of the container and each 10 years thereafter.”
7545-12 90° Adapter 7545-14 45˚ Adapter
Features
• Positive stop in the upper body protects against improper insertion
of a pipeaway adapter that might interfere with proper operation of (3/4-20 UNEF-2B THD)
the relief valve.

• Internal stem guide eliminates the need for a close fit between the
body and poppet, which lessens the chance of clogging due to 41/64"
foreign material.

• Single piece cold-headed stem provides more accurate


positioning of working parts for more consistent operation and TOP OF
CONTAINER
precise adjustment.
(3/4-14 NPT THD)
2-5/16"
• Two different deflector adapters and a protective cap are available
as accessories to provide complete protection.

• “Pop-action” design keeps product loss at a minimum.

D • Request RegO Relief Valves on all your original equipment forklift


cylinders for reliable performance.

Materials
Body........................................................................................ Brass
Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
Poppet..................................................................................... Brass
Guide....................................................................................... Brass
Seat Disc................................................................ Resilient Rubber

10
REGO

8545AK
YEAR
WARRANTY

Ordering Information
Accessories (Order Separately)
Flow Capacity SCFM/Air**
Deflectors***
Container Start To Discharge Container Protective
Part Number Type Setting PSIG Connection M. NPT (RegO Rated at 480 PSIG Cap 45° Elbow 90° Elbow
8545AK Dot 375 ¾” 400* 11557-19 7545-14 7545-12
* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders.
Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas.
** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the Foreword section.
*** Order protective cap #9103-54 or 7545-40.

D14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Semi-Internal “Pop-Action” Pressure Relief Valves for ASME Portable Containers
7583, 8684 and 8685 Series

Application
Designed for use as a primary relief valve on ASME containers such
as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists
containers systems on which these types of valves are mounted
outside the hood without additional protection, if mounted near the
hood and fitted with a protective cap.

Features

10
• Constructed of non-corrosive materials. REGO
• “Pop-action” design keeps product loss at a minimum.

• ASME rated for use with LP-Gas.


YEAR
• Request RegO Relief Valves on all your original equipment ASME WARRANTY
containers for reliable performance.

Materials
Body........................................................................................ Brass 7583G
Spring....................................................................................... Steel
Stem.......................................................................... Stainless Steel
Seat Disc................................................................ Resilient Rubber
Ordering Information
Flow Capacity SCFM/Air
A B C D
Start To Container Overall Height Above Wrench
Part Discharge Connection Height Coupling Hex UL (At 120% of Set ASME (At 120% of Set
Number Setting PSIG M. NPT (Approx.) (Approx.) Section Pressure) Pressure) Protective Cap (Included)
7583G ¾” 8 316” 1716” 1¾” 1980 1806 7583-40X
8684G 250 1” 9 3 8” 1916” 1 7 8” 2620 2565 8684-40
8685G 1¼” 11116 ” 11116” 2 3 8” 4385 4035 7585-40X
D
Application
Designed especially for use as a primary relief valve on large
stationary storage containers, these low profile relief valves are
generally mounted in half couplings. However, they are designed
so that the inlet ports clear the bottom of a full 2” coupling. This
ensures that the relief valve should always be capable of maximum
flow under emergency conditions.

Features

10
• High capacity, low turbulence design has a maximum guiding REGO
area providing for dependable shut-off after opening.

• Built-in spring stop limits the rise of the seat in full open position
and prevents the spring from going “solid.” YEAR
WARRANTY
• External 3” NPT threaded body allows easy attachment of vent
stacks. Optional pipeaway adapter has break-off groove to
prevent damage to the relief valve should piping be stressed by
damaging winds.
7534
• “Pop-Action” design keeps product loss at a minimum. Materials
Body........................................................................................ Brass
• No guiding projections around the seat disc retainer to bind and
Spring....................................................................................... Steel
hinder opening of valve if body is damaged.
Stem.......................................................................... Stainless Steel
Seat Disc................................................................ Resilient Rubber

Ordering Information
Flow Capacity SCFM/Air* Accessories
Start To Discharge Container Connection UL (At 120% of Set ASME (At 120% of Set Protective Cap
Part Number Setting PSIG M. NPT Pressure) Pressure) (Included) Pipeaway Adapter
7534B 125 6,025 -
2” 7534-40X 7534-20**
7534G*** 250 11,675 10,422
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the the Foreword section.
** 3” F. NPT outlet connection.
*** Other seat materials are available.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D15
External “Pop-Action” Pressure Relief Valves for ASME Containers and Bulk Plant
Installations AA3126, AA3130, 3131, 3132, 3133, 3135, AA3135, and A3149 Series

Application
Designed for use as a primary relief valve on ASME above ground
and underground containers, bulk plant installations and skid tanks.
The 3131 Series may also be used as a primary or secondary
relief valve on DOT cylinders, or as a hydrostatic relief valve. All
3135-10
working components of these relief valves are outside the container
connection, so the valves must be protected from physical damage.

Features
• “Pop-action” design keeps product loss at a minimum.

• Relief valve designed to automatically reseat firmly after


discharge.

• Resilient seat disc provides “bubble-tight” seal. 3135 A3149

• 3149 relief valves incorporate integral pipeaway adapter with


break off groove that protects the valve from piping stress
damage.
3132-10
• Optional pipeaway adapters have grooves that will break off to
protect the relief valve from damage should excess stress be
applied to the piping.

• 3149 relief valves include weep hole deflectors, installed to guard


against flame impingement on adjacent containers.

• Most are ASME rated for use with LP-Gas and anhydrous
ammonia.

Materials AA3135 W3132G

10
D Description 3131, 3132, 3133, 3135 AA3126 AA3130 AA3135 A3149 REGO
Body Brass Aluminum Rod* Upper Cold Rolled Steel Lower Ductile Iron
Liner None Stainless Steel
Spring Guide Brass Aluminum Stainless Steel
Spring Corrosion Resisant Steel Stainless Steel Stainless Steel or Coated Steel YEAR
Seat Disc Resilient Synthetic Rubber WARRANTY

Ordering Information
Flow Capacity SCFM/Air (a) Accessories
Start To A B C
Discharge Container Overall Wrench UL ASME Pipeaway Adapter
Setting Connection Height Hex (At 120% of (At 120% of Set Weep Hole
Part Number PSIG M. NPT (Approx.) Section Set Pressure) Pressure) Protective Cap Part Number Outlet Size Deflector
AA3126L030 30 ½” 2⅜” ⅞” (b) - 9103-54 AA3126-10 ½” M. NPT -
A3149L055 55 2608(c) -
2½” 10½” 4⅛” 3149-40 (h) Included (j)
A3149L200 200 8770 (c) -
AA3126L250 ½” 2⅜” ⅞” 277 (c) - 9103-54 AA3126-10 ½” M. NPT
3131G 3 7/16”
2060 1939 3131-41 (g) 3131-10 1” F.NPT -
T3131G ¾” 3 23/25” 1¾”
AA3130UA250 3 / ”
7 16 2045 1838 11557-110 AA3131-10 1” F. NPT
W3132G 1” 3340 - 3132-10 1¼” F. NPT
3132G 4130 - -
6 1/32” 2⅜” 3132-54 (g)
T3132G 3790 - 3132-10 1¼” F. NPT
250
MV3132G 3995 - -
1¼” 3133-11
3135G 5 21/32” 5770 5343 3135-54 (g) 3135-10
2 /16”
11
AA3135-40PR
AA3135UA250 6 13/32” 6430 6341 AA3135-10 2” F. NPT

3133G 1½” 5 15/16” 3⅛” 6080 - 3133-54 (g) 3133-10


A3149MG -
2½” 10½” 4⅛” 10390 3149-40 (h) Included (j)
A3149G 9153
AA3130UA265 ¾” 3 7/16” 1¾” 2125 1912 11557-110 AA3131-10 1” F. NPT -
265
AA3135UA265 1¼” 6 13/32” 2 11/16” 6703 6615 AA3135-40PR AA3135-10 2” F. NPT 3133-11
AA3126L312 312 ½” 2⅜” ⅞” 330 (c) - 9103-54 AA3126-10 ½” M. NPT -

(a) Flow rates shown are for bare relief valves. Adapters and pipeaways will (g) Cap supplied with chain.
reduce flow as discussed in the Foreword section. (h) Outlet 3½-8N (F) thread, will accept 3” M. NPT pipe thread.
(b) Not UL or ASME rated. .059 square inch effective area. (j) Weep hole deflector is Part No. A3134-11B.
(c) Not UL or ASME rated. RegO rated at 120% of set pressure.

D16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
External “Pop-Action” Supplementary Pressure Relief Valves for Small
ASME Containers and DOT Cylinders 3127 and 3129 Series

Application
Designed for use as a supplementary relief valve on small ASME
above ground and underground containers. They may also be used
as a primary or secondary relief device on DOT cylinders, or as
hydrostatic relief valves.

All working components of these relief valves are outside the


container connection, so the valves must be protected from physical
damage.

Features
• “Pop-action” design keeps product loss at a minimum.
3129-10 Pipe Away Adapter
• Relief valve designed to automatically reseat firmly after
discharge.

• Resilient seat disc provides a “bubble-tight” seal.

Materials
Body........................................................................................ Brass
Spring........................................................................ Stainless Steel
Seat Disc................................................................ Resilient Rubber

D
3127 Series

10
REGO

YEAR
WARRANTY

Ordering Information
Accessories

Flow Capacity SCFM/Air Pipeaway Adapter


A B C UL
Start To Container Overall Wrench (At 120% RegO Rated Suitable for Tanks
Container Discharge Connection Height Hex of Set at 480 w/Surface Area Protective
Part Number Type Setting PSIG M. NPT (Approx.) Section Pressure) PSIG*** Up To:* Cap Part Number Outlet Size
3127G ¼” 131/32” ⅞” 295 9103-54 -
ASME 250 - -
3129G ½” 219/32” 1⅛” 465 3129-40P 3129-10 ½” F. NPT
3127K ¼” 131/32” ⅞” 450 100 lbs./Propane 9103-54 -
DOT 375 -
3129K ½” 219/32” 1⅛” 780 200 lbs./Propane 3129-40P 3129-10 ½” F. NPT

* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the Foreword section.
** Not UL or ASME rated. RegO rated at 480 PSIG.
*** Meets DOT requirements.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D17
External Hydrostatic Relief Valves
3125, 3127, 3129, SS8001, SS8002, SS8021 and SS8022 Series

Application
Designed especially for the protection of piping and shut-off valves
where there is a possibility of trapping liquid LP-Gas or anhydrous
ammonia. They may be installed in pipelines and hoses located
between shut-off valves or in the side boss of RegO shut-off valves. Materials
Body (3125, 3127, 3129)......................................................... Brass
Features Body (SS8001, SS8002, SS8021, SS8022)............. Stainless Steel
• Relief valve designed to automatically reseat firmly after Spring....................................................................... Stainless Steel
discharge. Seat Disc............................................................... Resilient Rubber
• Resilient seat disc provides a “bubble-tight” seal.
• Available in both brass and stainless steel.
• Available in configurations that permit direct attachment of vent
piping when required.

Ordering Information
Accessories
Start To
Pipeaway
Discharge Valve Container Wrench
Setting Body Connection Height Hex Protective
Part Number PSIG Material M. NPT (Approx.) Section Cap Adapter or Threads
SS8001G** ¼” 11/16” 8001-55
⅞” -
SS8002G** Stainless ½” ⅞” 8022-54
SS8021G** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
250 1⅜”
SS8022G** ½” 8022-54 ⅜” NPT Thrds
⅞”
3127G ¼” 131/32” 9103-54 -
Brass
3129G ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001N** ¼” 11/16” 8001-55
Stainless ⅞” -
SS8002N** 265 ½” ⅞” 8022-54
Steel
D SS8021N**
3127H
¼”
¼”
1⅜”
131/32”
11/16”

⅞”
8001-55
9103-54
¼” NPSM Thrds
-
Brass
3129H ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001H** ¼” 11/16” 8001-55
275 ⅞” -
SS8002H** Stainless ½” ⅞” 8022-54
SS8021H** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
1⅜”
SS8022H** ½” ⅞” 8022-54 ⅜” NPT Thrds
3127P ¼” 131/32” 1⅛” 9103-54 -
Brass
3129P ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001P** ¼” 11/16” 8001-55
300 ⅞” -
SS8002P** Stainless ½” ⅞” 8022-54 3125 Series (.161” Orifice)***
SS8021P** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
1⅜” 3127 Series (.274” Orifice)***”
SS8022P** ½” ⅞” 8022-54 ⅜” NPT Thrds
3127J ¼” 131/32” ⅞” 9103-54 - 3129 Series (.386” Orifice)***
Brass
3129J ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001J** ¼” 11/16” 8001-55
350 ⅞” -
SS8002J** Stainless ½” ⅞” 8022-54
SS8021J** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
1⅜”
SS8022J** ½” 8022-54 ⅜” NPT Thrds
⅞”
3127K ¼” 131/32” 9103-54 -
Brass
3129K ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001K** ¼” 11/16” 8001-55
375 ⅞” -
SS8002K** Stainless ½” ⅞” 8022-54
SS8021K** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
1⅜”
SS8022K** ½” ⅞” 8022-54 ⅜” NPT Thrds
3125L 1/ ”
9 16 ⅝” 3125-40P
¼” -
3127L Brass 131/32” ⅞” 9103-54
3129L ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001L** 400 ¼” 11/16” 8001-55 SS8022G
⅞” - (.156” Orifice)***
SS8002L** Stainless ½” ⅞” 8022-54

10
SS8021L** Steel ¼” 11/16” 8001-55 ¼” NPSM Thrds
1⅜” REGO
SS8022L** ½” 8022-54 ⅜” NPT Thrds
⅞”
3127U ¼” 131/32” 9103-54 -
Brass
3129U ½” 219/32” 1⅛” 3129-40P 3129-10*
SS8001U** ¼” / ”
11 16 8001-55
SS8002U**
450
Stainless ½”
⅞”
⅞” 8022-54
- YEAR
SS8021U** Steel ¼”
1”
11/16” 8001-55 ¼” NPSM Thrds WARRANTY
SS8022U** ½” ⅞” 8022-54 ⅜” NPT Thrds
* ½” F. NPT outlet connection.
** Weep holes are not provided integral to these relief valves
*** Oriffice diameter
(.156” Orifice)***

D18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pressure Relief Valve with Check Device
RTG2831 Series *For Use Outside the United States

Application
These external valves are designed for use as a primary relief valve
on above ground domestic LPG DOT containers. The Check Device
(isolation valve) permits the exchange of the relief valve without the
necessity of evacuating the container.

Features & Benefits


• Relief valves provide “pop action” performance

• Weep hole is incorporated on the connection thread, which


indicates the check is closed and the valve may be removed.

• A metal to metal make up on the check device allows for a “signal


flow” of gas to act as a reminder that the container is unprotected
when the valve is removed.

• Complies with Standard CGA S-1.1 RTG2831V375


Materials
PRV
Body.......................................................................................... Brass
Spring......................................................................................... Steel
Stem............................................................................Stainless Steel
Seat Disc..................................................................Resilient Rubber

Check Device
Body.......................................................................................... Brass RTG2831N375
Stem.......................................................................................... Brass

NEW! VALUE CALCULATOR


NOW AVAILABLE D

(1.811 [46 mm] HEX)


(1.811 [46 mm] HEX)
Visit regoproducts.com (4.394)

(3.364)
(1.811 [46 mm] HEX)

(1-3/8 HEX)
(1-3/8 HEX)

10
REGO

(3/4-14 NPSM THD) RTG2831V


(1" NPT THD) TOP OF CONTAINER
YEAR (1" NPT THD)

WARRANTY

G2831N
Ordering Information RTG2831N

Includes Check Check


Includes Relief Valve Inlet Relief Valve Relief Valve Flow Relief Valve Flow
Part Number Check Device Inlet Device Outlet
Seat Connection Pressure Setting Rating (SCFM) Rating (M^3/min
Device Connection Connection
RTG2831N375 Yes 1"-11.5 3/4-14 NPSM- 3/4-14 NPSM-2A
Yes 375 PSI 2267.91 64.22
RTG2831V375* No NPTF THD 2B THD THD
*Replacement pressure relief valve kit.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D19
DuoPort™ Pressure Relief Valve Manifolds for Small Storage Containers
8542 Series

Application
Designed especially for use as a primary relief device on smaller
stationary storage containers, with 2” NPT threaded couplings.
These manifolds allow servicing or replacement of either of the two
relief valves without evacuating the container or loss of service. The
operating lever selectively closes off the entrance port to the relief
valve being removed while the remaining valve provides protection

10
for the container and its contents. The rating of each manifold is
REGO
based on actual flow through the manifold and a single pressure relief
valve, taking friction loss into account. It is not merely the rating of the
relief valve alone.
YEAR
Features WARRANTY
• Allows for relief valve removal and replacement on a periodic
basis without shutting down and evacuating the container.

• Unique seat ring assemblies provide a smooth tubular section to


preclude turbulence and ensure more efficient flow capacity.

• Operating lever is only locked in the mid-position or in a position


to seal either relief valve. Placement of the clapper disc in an
intermediate position could restrict flow through one of the relief
valves, causing it to chatter and destroy the resilient seat disc.

• A rubber plug with chain is provided to protect manifold outlet


threads where the relief valve has been removed.

• “Pop-action” design insures maximum protection with only minimal


product loss at moderately excessive pressures.

• Resilient relief valve seat disc provides “bubble-tight” seal. 8542

D • Relief valves are ASME rated for use with LP-Gas and anhydrous
ammonia.

Manifold Materials
Body............................................................................... Ductile Iron
Clapper Disc.............................................................. Stainless Steel ?
Bleeder Valve............................................................ Stainless Steel
Seat Disc................................................................................. Teflon
Packing......................................................................... Polyethylene

Relief Valve Materials


Body.................................................................... Forged Aluminum*
Spring Guide..................................................................... Aluminum
Spring........................................................................... Coated Steel
Seat Disc................................................ Resilient Synthetic Rubber
*A special coating is applied to the inlet threads to minimize the possibility of electrolytic action.

Ordering Information
Flow Capacity SCFM/Air** (at
Relief Valve Included
Application 120% of set pressure)
Start to Container
Part Number Discharge Connection Accessories
Setting PSIG M. NPT Inlet UL Rating (at ASME Rating
Quantity Part Number Connection Pipeaway 120% of set (at 120% of set
LP-Gas NH3
M. NPT Adaptors Pressure) Pressure)

8542G 5250 (1) NA


250 Yes No 3135MG 3135-10*
8542AG NA 5345 (1)
2” 2 1¼”
AA8542UA250 AA3135MUA250 6430 (1) 6058 (1)
265 No Yes AA3135-10*
AA8542UA265 AA3135MUA265 6615 (1) 6404 (1)

* 2” F. NPT outlet connection.


** Flow rating based on number of relief valves indicated in parenthesis ( ). Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow rates as discussed in the Foreword section.

D20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Delta Port™ Relief Valve Manifolds
8530/AA8530 Series

Application
Designed especially for use as a primary relief device on large 0036
stationary pressurized storage containers, the base is supplied with
a two-inch NPT threaded container connection. These manifolds
incorporate an additional relief valve, not included in the flow rating,
allowing for servicing or replacement of any one of the relief valves
without evacuating the container. The hand-wheel on the manifold
selectively closes off the entrance port to the relief valve being
removed while the remaining relief valves provide protection for the
container and its contents. All manifold flow ratings are based on flow
through the relief valves after one has been removed for service or
replacement.

Materials
Body................................................................................. Ductile Iron
Resilient Parts...........................................................................Teflon
Clapper Disc................................................................Stainless Steel
Bleeder Valve..............................................................Stainless Steel

Relief Valve Materials


Body (3135)............................................................................... Brass
Spring Gide (3135).................................................................... Brass
Body (AA3135)....................................................................Aluminum
Spring Guide (AA3135).......................................................Aluminum
Spring (3135 & AA3135)..............................................Stainless Steel
Seat Disc (3135 & AA3135)...................... Resilient Synthetic Rubber
8533AG D
Bleeder Valve

Hand-Wheel

Shut-Off Disc
Assembly

10
REGO

YEAR
WARRANTY
2” M.NPTF

Ordering Information
Application Relief Valve

Accessories
Start to Container Inlet ASME Flow Rating
Discharge Connection Connection Pipe-away SCFM (air) @ 120% of Set
Part Number Setting PSIG LPG NH3 M.NPTF Qty. Part Number M.NPT Adapter** Pressure *
8532AG 2 5,345 (1)
Yes No 3135MG 3135-10
8533AG 3 10,690 (2)
250
AA8532MA250 2 6,058 (1)
2” AA3135MA250 1¼”
AA8533MA250 3 12,116 (2)
No Yes AA3135-10
AA8532MA265 2 6,404 (1)
265 AA3135MA265
AA8533MA265 3 12,808 (1)
* Flow rating based on number of relief valves indicated in parentheses ( ).
Flow rates shown are for bare relief valves. Adapters and pipe-always will reduce flow rates as discussed in forwarding information in L-500 catalog. ** 2” F. NPT outlet connection

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D21
Multiport® Pressure Relief Valve Manifold Assemblies
for Large Storage Containers A8560, A8570 and AA8570 Series

Application
Designed especially for use as a primary relief device on large
stationary pressurized storage containers with flanged openings.
These manifolds incorporate an additional relief valve, not included
in the flow rating, allowing for servicing or replacement of any one of
the relief valves without evacuating the container. The handwheel on
the manifold selectively closes off the entrance port to the relief valve
being removed while the remaining relief valves provide protection for
the container and its contents. All manifold flow ratings are based on
flow through the relief valves after one has been removed for service
or replacement.

Features
• Allows for relief valve removal and replacement on a periodic
basis without shutting down and evacuating the container.

• “Pop-action” design of relief valves insures maximum protection


with only minimal product loss at moderately excessive pressures.

• A rubber plug with chain is provided to protect manifold outlet


threads where the relief valve has been removed.

• May be mounted directly to a welding neck flange or manhole


cover plate. Requires no inlet piping.

• Relief valves designed to automatically reseat firmly after


discharge.

• Resilient relief valve seat disc provides “bubble-tight” seal.

• Relief valves are ASME rated for use with LP-Gas and anhydrous
ammonia.
D
Materials
Body............................................................................... Ductile Iron
Resilient Parts......................................................................... Teflon
Clapper Disc.............................................................. Stainless Steel
Bleeder Valve............................................................ Stainless Steel

10
REGO

YEAR
WARRANTY

Bolt Stud and Nut Assemblies


Part Number
Number Consists of For Use With: For Connection To: Required
Modified 3” - 300#
7560-55 1-Bolt Stud All RegO and 4”-ANSI 300#
Welding Neck Flange 8
and Nut Multiports®
7560-56 Manhole Cover Plate
NOTE: Studs and Nuts are not included.

Relief Valve Materials


Description A8563, A8564, A8573, A8574
Body Upper Cold Rolled Steel Lower Ductile Iron
Liner Stainless Steel
Spring Guide Stainless Steel
Spring Coated Steel
Seat Disc Resilient Synthetic Rubber
*A special coating is applied to the inlet threads to minimize possibility of electrolytic action.

D22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Typical RegO Multiport® Pressure Relief Valve Manifold

Safety Groove
RegO Pressure Relief Valve
Excessive stress on vent piping
“Pop-action” insures maximum
attached to relief valve will break
protection with only minimum
valve body at this point, leaving
fluid loss at moderately
valve fully operative.
excessive pressures.
Handwheel
Large, heavy duty handwheel has
raised port numbers for selective
Weep Hole Deflector positioning of clapper disc. Raised
Port design of deflector prevents “arrow” below handwheel indicates
any ignited fluid ejected from the exact position of clapper disc at all
weep hole, while the relief valve is times.
functioning, from impinging on the
storage container or adjacent piping Clapper Disc
and equipment. Shown in position to remove relief
valve. Normally, clapper disc is
positioned between any two relief
valves.
Resilient Seat Disc
Assures positive shut-off. Bleeder Valve
Shown in “closed” position to bleed
off pressure trapped between relief
Manifold Seat Ring valve and clapper disc prior to
Has integral teflon seat ring for removal of relief valve.
positive shutoff of valve port by
clapper disc. Ductile Iron Body
Rugged. Has corrosion resistant
lacquered finish.
Instruction Plate Flanged Tank Connection
For relief valve replacement. Available with either a modified
ANSI 3” (4” port opening) or a 4”
Plug Assembly
Protects manifold outlet threads
ANSI 300# flanged connection.
Mates respectively with modified
D
and keeps foreign material out ANSI 3” 300 lb. flat face steel flange
of manifold when relief valve is and ANSI 4” 300 lb. 1⁄16” raised
removed for retest. face steel flange.

Spacious Manifold Port


Flange Dimensions Passages large unobstructed throat
ensures minimum capacity loss.
Manifold Port Flange
Series Flange Size Flange Drilling Diameter Gasket Manifold is bolted directly to storage
container opening, eliminating any
Modified 3” (8) ⅞” Bolt Holes on a
3” restrictions.
A8560 300# 6⅝” Bolt Circle Diameter 4”
7564-48

10
(4” Port Dia) Flat Faced.
REGO Gasket
(8) ⅞” Bolt Holes on a Johns-Manville Flexitallic flange
A8570 4” ANSI 4”
7⅞” Bolt Circle Diameter 4”
AA8570 300#
1/16” Raised Faced.
7565-48 gasket furnished with each manifold
assembly.
YEAR
WARRANTY
Ordering Information
Application Relief Valve
Flow Capacity SCFM/Air** At
Accessories 120% of Set Pressure
Start To Container Inlet
Discharge Flange Connection Pipeaway
Part Number Setting PSIG LP-Gas NH3 Connection Quantity Part Number M. NPT Adapters UL Rating ASME Rating
A8563G 3 18,500 (2)
3”-300#*
A8564G 4 27,750 (3) Not
A3149MG
A8573G 3 18,500 (2) Applicable
4”-300#
A8574G 4 27,750 (3)
250 Yes Yes 2½” ****
A8563AG 3 18,300 (2)
3”-300#*
A8564AG 4 Not 27,459 (3)
A3149G
A8573AG 3 Applicable 18,300 (2)
4”-300#
A8574AG 4 27,459 (3)
* For use with modified 300# ANSI flange with 4” port.
*** 2” F. NPT outlet connection.
** Flow rating based on number of relief valves indicated in parentheses ( ).
**** Outlet 3½-8N (F) thread, will accept 3” M. NPT pipe thread.
Flow rates shown are for bare relief valves. Adapters and pipeaways will
reduce flow rates as discussed in the Foreword section.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO D23
Adhesive Warning Label
8545-500

The following warning information, Part Number 8545-500, is included Part


with each shipment of pressure relief valves and relief valve manifolds Number
to the first purchaser of the product from the factory. 8545-500 Adhesive Warning Label

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from RegO and
Authorized Product Distributors.

DANGER READ THIS FIRST WARNING


LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Make sure you are thoroughly trained before you attempt any pressure relief installation or maintenance.
Improper conditions or procedures can cause accidents resulting in property damage and personal injury.
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &
Maintance” and RegO Safety Warning “Pressure Relief Valves” found in the relief valve section of the L-500
& L-102 Catalogs. Follow its recommendations.
Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is
essential in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed
to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper
handling procedures. Refresher training shall be provided at least every three years and shall be documented.”
Make sure this valve is the proper one for this installation. Avoid misusing LP-Gas equipment. Flow rates
in the charts are for bare relief valves found in the relief valve section of the L500 & L102 Catalogs. The
addition of deflectors, pipeaway adapters and piping will restrict the flow. To properly protect any container,
the total system flow must be sufficient to relieve pressure at the pressure setting of the relief valve in
accordance with all applicable codes.
Use only RegO adapters on RegO relief valves. Adapters not designed specifically for piping away RegO
relief valves, such as those with 90° turns or reduced internal diameters, will decrease flow dramatically.
These should never be used as they can cause the relief valve to chatter and eventually destroy itself.
Apply thread joint compound compatible with LP-Gas on valve external threads only. Make sure compound
never comes into contact with other parts of the valve.
Install valves by applying force to wrenching flats only.

Tighten pipe threads approximately 1 to 1½ turns beyond the hand-tight insertion point using a wrench which
avoids damage to other valve parts.
Check for damage after valve installation. Check that the pressure relief valve is clean and free of foreign
material. Make sure protective cap is properly in place.
Check that there are no leaks with a non-corrosive leak detection solution before filing with LP-Gas.
Purge container before filling with LP-Gas (refer to the RegO LP-Gas Serviceman’s Manual for recommended
procedure.)
In selecting a label for posting at the installation site, consider RegO part number 901-400 along with your
own, NPGA’s and others.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment. See
RegO Safety Warning “Pressure Relief Valves” found in the relief valve section of the L-500 & L-102 Catalogs.

D RegO requests that this information be forwarded to your customers. Additional copies are available from
RegO and your authorized RegO Distributor.
Printed in USA 07A-0910-0386
PRODUCTS
R Part number 8545-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

8545-500

D24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section E
Globe and Angle Valves E E

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
E warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

E2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. E
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E3
LP-Gas Hose-End Filling Valves (With ACME Connectors)

Safety Warnings Purpose


In its continuing quest for safety, RegO publishes a series of bulletins explaining the hazards associated with the
use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these factual bulletins will make clear to
LP-Gas dealer managers and service personnel, that the utmost care and attention must be used in the installation,
inspection, and maintenance of these products, or problems could occur which would result in injuries and property
damage.

The National Fire Protection Association NFPA 58 Liquefied Petroleum Gas Code - 2020 Edition states in Section
4.4 Qualification of Personnel; ”Persons whose duties fall within the scope of this code shall be provided with
training that is consistent with the scope of their job activities and that includes proper handling and emergency
response procedures. Refresher training shall be provided at least every 3 years, initial and subsequent training
shall be documented”. These “RegO Safety Warnings” may be useful in training new employees and reminding
older employees of hazards that can occur. It is recommended that all employees complete the Propane Education
Research Council’s Certified Employee Training Program.

Nature of Warnings
It is recognized that warnings should be as brief as possible, but
factors involved in filler valve and filling valves failure are not simple.
They need to be fully understood so that proper procedures and
maintenance can be used to prevent accidents. If there is a simple
warning, it would be:

Loosen filling valve from filler valve very slowly.


If there is a leak, know procedure to follow.
Loosen slowly.
This bulletin is not intended to be an exhaustive treatment of the If gas continues
subject of filler valves and certainly does not cover all safety practices to vent, retighten
that should be followed in the installation, operation and maintenance ACME connector
of LP-Gas systems, which include filler and filling valves. and follow company
emergency
Hose-End Filling Valves With ACME Connectors procedures.
Hose-end valves must never be dragged over the ground or Inspection of Quick Acting Filling Valves
E dropped or banged into the truck when the hose is reeled in. Valves should be inspected daily to make sure locking mechanism
functions properly.
They could open accidentally or they could be damaged. Dragging
will cause abnormal wear and eventual valve failure. Foreign material The ACME threads should be examined for wear, dents or nicks and
will lodge in the connector which can cause failure of the filler valve. the seating area should be clean and smooth.

To prevent hazardous conditions, operators should follow this The retaining ring on the filler connection should be examined to
procedure on every filling application: make sure it is properly holding the female ACME rotating nut or
handle so as to keep the surface that seats on the filler valve gasket
Always wear gloves and eye protection. protected.
Check for foreign material in hose-end valve and the filler valve,
If any problems are evident, valves should be immediately replaced
and if present, remove with extreme care. If material cannot be
safely removed, do not proceed with filling and replace valve. or repaired.

Make sure the ACME connector spins on easily by hand. Larger Filler and Filling Valves
For 2¼” and 3¼” valves with ACME connections, use only the special
If leak is noticed when filling is started, stop the operation and wrenches designed for the purpose.
correct the leaking condition.
Do not use pipe wrenches or hammers to tighten the connections. All
After filling, bleed the gas trapped between the filler valve of the previous warnings about the smaller valves also apply here.
and hose-end valve by using the vent on the hose-end valve
or by slightly loosening coupling nut to vent the gas before General Warning
disconnecting. All RegO products are mechanical devices that will eventually
become inoperative due to wear, contaminants, corrosion and aging
If gas does not stop venting, then filler valve or hose-end
components made of materials such as rubber and metal. The
valve is leaking. Do not disconnect filling connector. This is a
hazardous situation and your company procedure for handling environment and conditions of use will determine the safe service
this problem must be carefully followed. life of these products. Periodic inspection and maintenance are
essential. Because RegO products have a long and proven record of
Make sure your company has such a procedure. Inspection of quality and service, LP-Gas dealers may forget the hazards that can
Filling Valves with Handwheel occur because a filler valve or a filling valve is used beyond its safe
Valves should be inspected at least once a month to be sure that the service life. Life of these valves is determined by the environment
valve handle is tight and not damaged, that the stem is not bent and in which they “live.” The LP-Gas dealer knows better than anyone
that there is no “play” in the threads in the bonnet. “Play” will normally what this environment is. Note: There is a developing trend in state
not be noticed if the valve is under pressure. legislation and in proposed national legislation to make the owner of
products responsible for replacing products before they reach the
The ACME threads should be examined for wear, dents or nicks and end of their safe useful life. LP-Gas dealers should be aware of the
the seating area should be clean and smooth. legislation which could affect them.

E4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks
and Dispensing Stations A7793A and A7797A

Application
Designed to vastly reduce the amount of product vented when
disconnecting bobtail delivery trucks, dispensing systems and
anhydrous ammonia nurse tanks. These valves provide instant,
full-on flow at the flip of a handle. Shut-off is instant and the handle
locks for added protection. This “top of the line” hose-end valve is a
fully contained unit that does not require additional filling adapters or
connectors.

Features
• Minimizes product venting loss, when disconnecting, instantly by
housing the seat disc at the bottom of the built-in ACME filling
connector.

• Vents less than 2cc of liquid when disconnected.

• “V”-ring spring-loaded pressure seal design provides for


dependable, leak-free operation. No packing to retighten or
replace.

• Operator friendly. Contoured handle rotates a full 360° and large,


easy to grip filling connector make the valve easy to handle.

• Self locking handle is operator opened and closed to prevent


against accidental opening of the valve.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)


A7793
Materials
Body............................................................................... Ductile Iron E
“V”-Ring................................................................................... Teflon
Stem.......................................................................... Stainless Steel
Seat Disc........................................................... Synthetic Elastomer
ACME Connector....................................... Aluminum w/Steel Insert
Seal Housing............................................................. Stainless Steel
Lever......................................................................... Stainless Steel
Bonnet........................................................... Cadmium Plated Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Flow at 1 PSIG (Cv) Pressure Drop* (GPM/
Part Number Inlet Connection (F. NPT) Outlet Connection (F. ACME) Locking Handle
Propane)
A7793A ¾” 1 ¾” Yes 16.0
A7797A 1” 1 ¾” Yes 16.0
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: A7797 @ 9 PSIG = 16.0 x√9 = 48.0 GPM/propane. For NH3 flow,
multiply propane flow by .90.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E5
Quick-Acting Low Emission Unloading Adapter for Bobtail Delivery Trucks
and Dispensing Stations A7797L and A7793L

Application
Designed to vastly reduce the amount of product vented when
disconnecting bobtail delivery trucks, dispensing systems and
anhydrous ammonia nurse tanks. These valves provide instant,
full-on flow at the flip of a handle. Shut-off is instant and the handle
locks for added protection. This “top of the line” hose-end valve is a
fully contained unit that does not require additional filling adapters or
connectors.

Features & Benefits


• Minimizes product venting loss, when disconnecting, instantly by
housing the seat disc at the bottom of the built-in ACME filling
connector.

• Vents less that 0.5cc of liquid when disconnected.

• “V”-ring spring-loaded pressure seal design provides for


dependable, leak-free operation. No packing to retighten or
replace.

• Operator friendly. Contoured handle rotates a full 360° and large,


easy to grip filling connector make the valve easy to handle.

• Self locking handle is operator opened and closed to prevent


against accidental opening of the valve.

• Meets Mexican Standard NMX-X-023-SCFI-2013

• Temperature range of -40°F to +165°F. (-40°C to +73°C)


A7793L
• MAWP: 400 PSIG(27 Bar)

4 5/8"
E APPROX.

Materials
Body............................................................................... Ductile Iron
“V”-Ring................................................................................... Teflon
Stem.......................................................................... Stainless Steel INLET
ACME THREADS
Seat Disc........................................................... Synthetic Elastomer
ACME Connector....................................... Aluminum w/Steel Insert
Seal Housing............................................................. Stainless Steel
Lever......................................................................... Stainless Steel
Bonnet........................................................... Cadmium Plated Steel
12 1/8"
APPROX.

10
REGO LOW EMISSION 7 5/8"
APPROX.

YEAR
FILLING
WARRANTY CONNECTION

OUTLET 2 1/16"
ACME THREADS APPROX.

Ordering Information
Flow at 1 PSIG (Cv) Pressure Drop*
Part Number Inlet Connection (F. NPT) Outlet Connection (F. ACME) Locking Handle
(GPM/Propane)
A7793L ¾” 3.61
1¾” Yes
A7797L 1” 4.42

E6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations
A7707L and A7708L

Application
Designed especially for safe operator handling of LP-Gas in bobtail
delivery truck, dispensing systems and anhydrous ammonia nurse
tank service.

These valves provide instant, full-on flow at the flip of the handle
and provide instant positive shut-off with a handle lock for added
protection.

Features
• “V”-ring spring-loaded pressure stem seal provides for leak-proof
operation. No packing to retighten or replace.

• Self locking handle is operator opened and closed to prevent


against accidental opening of the valve.

• Large, contoured handle provides firm, comfortable grip. A7707L

• Full swivel handle rotates 360° so the valve can be operated from
any angle.

• Built-in vent valve on the downstream side of the valve permits


bleeding of trapped product to ensure safe uncoupling.

• Can be used with a variety of RegO filling adapter connectors.

• Swivel seat disc minimizes grinding on the body seat and ensures
longer service life.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)


E

Materials
Body................................................................................. Ductile Iron
“V”-Ring.................................................................................... Teflon A7708L
Stem........................................................................... Stainless Steel
Seat Disc............................................................ Synthetic Elastomer
Valve Lever................................................................. Stainless Steel
Seal Housing.............................................................. Stainless Steel
Bonnet............................................................ Cadmium Plated Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Accessories
Filling Connectors**
Extended Compact
Inlet & Outlet Locking Flow at 1 PSIG Pressure Drop (Cv)
Part Number Body Design Connection (F. NPT) Handle (GPM/Propane)** Steel Brass Steel
A7707L Straight 18.0
1” Yes A7575L4 3175A A3175A
A7708L Angle 22.0
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop.
Example: A7708L @ 9 PSIG = 22.0 x 9 = 66.0 GPM/propane. For NH3 flow, multiply propane flow by .90.
* * See appropriate catalog section for additional information.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E7
2” ACME Low Emission Hose End Valve for Loading Bobtails and
Transports A7914A

Application
The A7914A Low Emission valve is designed to reduce the amount
of product vented when disconnecting bobtail and transport loading
hoses. This valve provides a full-on flow when pressing the release
trigger and the lifting of an easy grip handle. Lowering the handle will
immediately stop flow and lock the lever in the closed position. This
valve can be used with any standard 3¼” Male ACME connector, or our
6588LE and 6589LE minimum loss filler valves.

Features
• Minimizes product discharge at disconnect.

• Vents less than 2 cc of liquid when disconnected.

• California CARB Compliant for fugitive emissions.

• Contoured handle rotates 360° and has a large easy to turn


ACME swivel connector.

• Self-locking handle is operator opened and closed, designed to


prevent accidental opening of the valve.

• Bypass mechanism in the seat area allows the upstream pressure


to quickly equalize when the handle is partially moved to the open
position. A7914A

• Protective screen on inlet side prevents debris from entering.

• Spring-loaded Teflon “V” packing for bonnet/stem assembly


provides long service life.
E
• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

Materials
Body.................................................................................. Ductile Iron
“V” –Rings..................................................................................Teflon
Stem.............................................................................Stainless Steel
Acme Connector.................................................... Plated Ductile Iron
Seal Housing................................................................Stainless Steel
Bonnet............................................................................. Plated Steel
Lever............................................................................Stainless Steel
Seat Disc..................................................................Synthetic Rubber

10
REGO

YEAR
WARRANTY

Ordering Information
Flow at (Cv) Pressure Drop GPM Propane
Part Number Inlet Connection Outlet Connection Locking Handle 1 PSIG 10 PSIG
A7914A 2” F.NPT 3¼” F.Acme Yes 55 174
*To obtain approximate flow at other than 1 PSIG drop, multiply flow in table by square root of pressure drop. Example A7914 @ 9PSIG drop = 55 X √9 = 165 GPM /propane

E8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Quick-Acting Valves for Crop Driers and Charging Manifold Hoses
7554 Series

Application
7554S Series valves provide instant shut-off and fast opening control
on LP-Gas crop driers. They are also ideal for charging manifold
hoses, stationary fuel transfer hoses and other applications requiring
quick, positive shut-off. They are not for use with delivery truck hoses
because the handle could snag on the ground and open the valve as
the hose is reeled back to the truck.

7554L Series valves feature a locking handle device to help prevent


accidental opening of the valve. It is ideal for all the same applications
as the 7554S Series and may be used on delivery trucks as it
incorporates the locking handle design.

Both valve series must be installed so that flow through the valve is
opposite to that of a conventional globe valve. This allows the inlet
flow to assist in closing the valve and prevents the valve from being
opened by high pump pressures.

Features 7554S
• Quick-acting design speeds transfer operations, permitting rapid,
one-handed opening and closing.

• Resilient seat disc provides positive shut-off.

• Flange seal stem design provides for leak-proof operation. No


packing to retighten or replace.

• 7554L Series incorporates locking handle to prevent accidental


opening of the valve.

• Vent valve installed on the downstream side of the valve permits


bleeding of trapped product to ensure safe uncoupling.
E
• Swivel seat disc minimizes grinding on the body seat and ensures
longer service life.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

Materials
Body................................................................................. Ductile Iron
Bonnet....................................................................................... Brass
7554LV
Stem Seal................................................................................. Teflon
Stem........................................................................... Stainless Steel
Seat Disc................................................................. Nitrile Elastomer
Seal Housing...............................................................................Brass
Lever...........................................................................................Brass

10
REGO

YEAR
WARRANTY

Ordering Information
Part Number Inlet & Outlet Connection (F. NPT) Locking Handle Flow At 1 PSIG (Cv) Pressure Drop* (GPM/Propane)
7554SAV No
½” 7.3
7554LAV Yes
7554SV No
¾” 11.3
7554LV Yes
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table
by square root of pressure drop. Example: 7554LV @ 9 PSIG = 11.5 X 9 = 34.5 GPM/
propane.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E9
Quick-Acting Valves for Cylinder Charging Hoses
7053T and 7901T Series

Application
Designed primarily for use on cylinder charging hoses to provide fast,
convenient shut-off and fast opening.

These valves must be installed so that flow through the valve is in


the opposite direction to that of a conventional globe valve. This
allows the inlet flow to assist in closing the valve, and even more
important, helps prevent the valve from being forced open by high
pump pressure.

Features
• Quick-acting design speeds transfer operations.

• Permits easy, one-handed opening and closing of the valve.

• O-ring stem seal design.

• Provides quick, positive shut-off.

• Temperature range of -40°F to +165°F. (-40°C to +73°C) 7901T

• MAWP: 400 PSIG(27 Bar)

23/16”

Materials 2½”
Body (7053T, 7901)..................................................... Forged Brass
O-Ring.................................................... Resilient Synthetic Rubber
E Bonnet Assembly (7053T, 7901)............................................. Brass 7901TA
Seat Disc................................................. Resilient Synthetic Rubber
Handle (7053T, 7901)............................................................... Brass
Springs........................................................................Stainless Steel

2½”

23/16”

10
REGO

7053T
YEAR
WARRANTY 317/32”

Ordering Information
Part Number Inlet Connection (F. NPT) Outlet Connection (F. NPT) Body Material Flow At 1 PSIG (CV) Pressure Drop* (GPM/Propane)
7901T ¼” ¼”
7901TA ⅜” ⅜”
7901TB ¼” Brass 1.95
7901TC ½”
½”
7053T
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square
root of pressure drop. Example: 7901T @ 9 PSIG = 1.95 x 9 = 5.85 GPM/propane. For NH3 flow,
multiply propane flow by .90.

E10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Quick-Acting Valves for Dispensing Hoses
7901TL Series

Application
Designed primarily for use on dispensing hoses to provide safe,
convenient shut-off and fast opening. These valves feature a locking
handle device to help prevent accidental opening of the valve.

Features
• Quick-acting design speeds transfer operations.

• Permits easy, one-handed opening and closing of the valve.

• O-ring stem seal design.

• Provides quick, positive shut-off.

• Locking handle device is operator opened and closed to prevent


against accidental opening of the valve.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

Materials
Body............................................................................ Forged Brass
O-Ring.................................................... Resilient Synthetic Rubber 7901TL Series
Bonnet Assembly..................................................................... Brass
Seat Disc................................................. Resilient Synthetic Rubber
Handle...................................................................................... Brass
Springs........................................................................Stainless Steel
E

10
REGO

YEAR
WARRANTY

Ordering Information For hose end adapters see section J


Part Inlet Connection
Number (F. NPT) Outlet Connection (F. NPT) Body Material Flow At 1 PSIG (CV) Pressure Drop* (GPM/Propane)
7901TLA ⅜” ⅜”
7901TLB ¼” Brass 1.95
½”
7901TLC ½”
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by
square root of pressure drop. Example: 7901T @ 9 PSIG = 1.95 x 9 = 5.85 GPM/propane.
For NH3 flow, multiply propane flow by .90.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E11
“V”-Ring Seal Globe and Angle Valve Information

General Information Installation and Operation Note


RegO Globe and Angle Valves are designed and manufactured Containers and pipe lines should be thoroughly cleaned before globe
especially to meet the rigid requirements of the LP-Gas industry. The and angle valves are installed. Large particles of solid foreign matter
high quality construction and wide variety of sizes and styles also can permanently damage the seating surface in the valve body,
make them highly suited to many other industries such as anhydrous causing the valve to leak. Use a minimum amount of a suitable pipe
ammonia, chemical and petrochemical. dope on the male connecting threads as excess amounts may fall off
and be carried into the valve, causing damage to the seat or other
These ductile iron valves are available in both threaded and flanged operating parts.
connections. Threaded connections are available in ½” F. NPT to 3”
F. NPT sizes. Flanged connections are available in 1½”, 2” and 3”
It is totally unnecessary to use excess force in opening or closing
pipe sizes.
RegO valves. The type of seat disc material used and the general
design of these valves permits them to be opened and closed easily.
The ductile iron used in these valves has a 60,000 PSIG tensile
strength which closely approaches that of steel castings. Its yield Proper valve operation insures unusually long life.
strength of 45,000 PSIG and elongation of 15% is also comparable
to that of steel castings. These material features ensure the ability of Wrenches must never be used to operate valves equipped with
the valve body to withstand impact, wrenching stresses and thermal handwheels and designed for hand operation.
shock. This ductile iron conforms to ASTM specification A395.
Downstream Accessory Boss
RegO globe and angle valves are designed for working pressures These RegO valves incorporate a plugged ¼” F. NPT boss on the
up to 400 PSIG WOG and for operating temperatures from -40° F. downstream side of the body for attaching either a hydrostatic relief
to +160° F. valve or vent valve. Boss size on the 2” and 3” valves has been
increased to allow a ¾” drilling for accommodation of a standard
“V”-Ring by-pass valve or jumper lines.
Stem Seal Hydrostatic Relief—When the design of the piping installation
is such that liquid may be locked between two shut-off valves,
a hydrostatic relief valve should be installed in the lines
The “V”-ring spring-loaded pressure seal used in these RegO globe between the valves. The pressures which can develop due to
and angle valves is the most effective stem seal yet developed. It temperature increase in a liquid fill line are tremendous and
should not be confused with conventional valve stem packing where can easily damage the valves or piping unless a hydrostatic
the seal is obtained by compressing the packing around the stem by relief valve is installed.
means of a packing gland with resultant hard operation and frequent
E packing replacement.
Vent Valve—If the globe or angle valve is used as a shut-off
The wax like surface of the teflon “V”-ring seal and consequent low valve on a loading hose, a vent valve should be installed in the
friction ensures leak-tight performance for an indefinite period where
downstream boss to allow liquid trapped beyond the shut-off
periodic retightening of the packing is not required and the seal
provides extra long service life.
valve to be vented before disconnecting the hose coupling.

In the RegO “V”-ring design, the seal is effected by the pressure Replace Gate Valves with Flanged Valves
expanding the “V”-shape of the seal, forcing it against the stem and Except for standard flange sizes, RegO Flanged Globe and Angle
bonnet surfaces to prevent leakage. The higher the pressure within
Valves are smaller and lighter than contemporary valves, thus
the valve, the more effective the seal becomes. A spring loaded
washer under the “V”-rings keeps them in an expanded position to reducing price and shipping costs and making them far easier to
ensure an effective seal under low pressure conditions. A wiper ring, install. RegO face-to-face flange dimensions conform to gate valve
located above the seal, keeps the seal free from grit, and/or other dimensions, making replacement of most gate or plug valves with
foreign material that may hamper operation. RegO valves simple and easy.

General Features
Heavy Duty Handwheel
Teflon “V”-Ring
provides easy operation.
Spring-Loaded Pressure
Seal for leak-proof
O-Ring Wiper keeps sand operation. No packing to
and grit away from pressure adjust or replace.
seal and stem threads.

Heavy Duty ACME Threads Stainless Steel Stem is centerless


for quick action and smooth ground to provide a smooth
operation. sealing surface.

Rugged Ductile Iron Body


Swivel Seat Holder
won’t crack or fracture
promotes long life.
from wrenching, dropping
or hammer blows.
Synthetic Rubber Seat
assures easy, positive Circular Bridge is
shut-off. contoured to provide
extra high capacity and
low pressure drop.

E12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
“V”-Ring Seal Globe and Angle Valves for Bulk Storage Containers,
Transports, Bobtails and Plant Piping A7500 Series and TA7500 Series

Application
Specifically designed to ensure positive shut-off and long,
maintenance free service life in liquid or vapor service on bulk storage
containers, transports, bobtails, cylinder filling plants and plant piping.

The high quality construction and wide variety of sizes make them
highly suited for use with LP-Gas, anhydrous ammonia and in the
chemical and petrochemical industries.

Features
• “V”-ring spring-loaded pressure stem seal provides for leak-proof
operation. No packing to retighten or replace. TA7034
• Circular bridge in the globe design and a dropped seat in the
angle design achieve greater flow with less pressure drop.
• Swivel seat disc assembly minimizes the seat disc from grinding
on the body seat. The seat disc stops rotating as soon as it
touches the body seat. This feature provides for good seat A7518FP
alignment and ensures long seat life.
• ¼” F. NPT plugged boss on the downstream side of the valve
body allows attachment of a hydrostatic relief valve or vent valve.
• “V”-ring stem seal virtually eliminates hard to turn handles
frequently encountered with packed type seals.
• Heavy duty rolled ACME stem threads provide quick action and
long service life.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
A7505AP
• MAWP: 400 PSIG(27 Bar)
A7514AP

Materials
Body............................................................................... Ductile Iron
Bonnet (7034, 7505-7508)....................................................... Steel
Bonnet (7509-7518)....................................................... Ductile Iron
A7513AP E
Valve Stem................................................................ Stainless Steel
Wiper Ring............................................................. Synthetic Rubber
Seat Disc........................................................... See Ordering Chart
“V”-Rings................................................................................. Teflon
Handwheel..................................................................... Ductile Iron
Spring........................................................................ Stainless Steel

10
REGO

YEAR A7517AP
WARRANTY
A7517FP

Ordering Information
Part Number Accessories
Flow at 1 PSIG Pressure
Buna N Seat Discs Teflon Seat Discs* Drop (Cv) (GPM/Propane)***
Inlet and Outlet Hydrostatic Relief
Globe Angle Globe Angle Connection Port Diameter Globe Angle Valve Vent Valve
- - TA7034P TA7034LP ½” F. NPT 10.0 14.8
¾”
A7505AP A7506AP TA7505AP TA7506AP ¾” F. NPT 12.0 17.7
A7507AP A7508AP TA7507AP - 1” F. NPT 1” 17.8 22.0
A7509BP A7510BP TA7509BP TA7510BP 1¼” F. NPT 1¼” 36.5 54.0
A7511AP A7512AP TA7511AP TA7512AP 1½” F. NPT 43.0 55.5
1½” SS8001U TSS3169
A7511FP - TA7511FP 1½” Flange** 46.0 -
-
A7513AP A7514AP TA7513AP 2” F. NPT 75.0 88.5
2”
A7513FP A7514FP TA7513FP TA7514FP 2” Flange** 78.0 133.0
A7517AP A7518AP TA7517AP - 3” F. NPT
3⅛” 197.0 303.0
A7517FP A7518FP TA7517FP - 3” Flange**

* Teflon seat discs on valves built to order.


* * 300# ANSI R.F. Flange.
* * * To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in chart by square root of pressure drop.
Example: 7514FP @ 9 PSIG = 133 x √9 = 399 GPM/propane. For NH3 flow, multiple propane flow by .90.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E13
Globe and Angle Valve Dimensions

Dimensions
Flanges
Valve Number
Drawing (A or TA Prefix) Inlet & Outlet Port Diameter A B C D E F G

7034P ½” F. NPT
¾” 311⁄16”
7505AP ¾” F. NPT

A -

7507AP 1” F. NPT 1” 45⁄16”


C B
B
4¾” - - - -
7034LP ½” F. NPT
¾” 1¾”
7506AP ¾” F. NPT
UL
®

7508AP 1” F. NPT 1” 2”

G
7509BP 1¼” F. NPT 1¼” 741/64” 4⅞”
A
7511AP 1½” F. NPT 1½” 63⁄4” 53⁄16” -
- - - -
7513AP 2” F. NPT 2” 73⁄16” 5⅞”

C 7517AP 3” F. NPT 3⅛” 13¼” 9” 9”


G 7510BP 1¼” F. NPT 1¼” 6¾” 2¼”

7512AP 1½” F. NPT 1½” 613⁄16” 27⁄16”


A 5¼”
E 7514AP 2” F. NPT 2” 73⁄16” 211⁄16” - - - -

B
7518AP 3” F. NPT 3⅛” 11¾” 4”
B 9”
G
7511FP 1½” Flange 1½” 79⁄16” 7½” 6⅛” ¾” 2⅞”
E
A 5¼”
7513FP 2” Flange 2” 87⁄16” - 8½” 6½” ⁄ ”
13 16 3⅝”
F D

7517FP 3” Flange 3⅛” 13¼” 11⅛” 8¼” 1⅛” 5” 9”


C
G

7514FP 2” Flange 2” 7½” 5¼” 6½” ⁄ ”


13 16 3⅝” 5¼”
A
D -
B

7518FP 3” Flange 3⅛” 11¾” 6¼” 8¼” 1⅛” 5” 9”


E
D B
F

NOTE: Regarding 7505AP through 7510BP — the thread used for assembling the bonnet to the body of the valve is a left hand thread. We advise our customers to be cognizant of this assembly
design in attempting to remove the bonnets of these valves in order to avoid serious damage to the valves.

Flange Dimensions
Valve Number (A or TA
Prefix) Size Flange Drilling D E F H

⅞” Bolt Holes on a 4½”


7511FP 1½” 6⅛” ⁄ ”
13 16 2⅞” ¾”
Bolt Circle Diameter

7513FP ¾” Bolt Holes on a 5”


2” 6½” ⅞” 3⅝” ⁄ ”
13 16

7514FP Bolt Circle Diameter

7517FP ⅞” Bolt Holes on a 6⅝”


3”* 8¼” 1⅛” 5” 11⁄16”
7518FP Bolt Circle Diameter

* Reducing screwed flanges are available for reducing 1½” flange to 1 or 1¼” pipe thread and 3” flange to 2½” pipe thread. Order from your local piping supplier.

E14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
2” & 3” Globe/Angle valves with Built-in Automatic Back Check
HA7513AP/HA7514AP and HA7517AP/HA7518AP

Application
Designed for use in conjunction with our 6588LE and 6589LE low
emission filler valves installed on bobtails and transports. The valves
are designed to stop flow out of the container when the hand- wheel
is closed. They incorporate an automatic integral back check that is
designed to allow flow back into the container to prevent liquid from
becoming trapped between the 6588/89LE and the closed globe/
angle valve.

Features
• V-ring spring loaded pressure stem seal provides for
leak-proof operation. No packing to retighten or replace.

• Circular bridge in globe design and a dropped seat in the


angle design achieve greater flow with less pressure drop.

• Swivel seat disc assembly minimizes wear which provides for


good alignment and long seat life.

• ¼” F.NPT plugged holes on upstream and downstream sides


of the valve. HA7513AP

• Heavy duty rolled ACME stem threads provide quick action


and long service life.

• Seat Disc assembly incorporates an automatic back check


valve, eliminating the need for a separate hydrostatic relief valve.

Materials
E
Body ................................................................................ Ductile Iron
Stem............................................................................Stainless Steel
Seat.............................................................................Stainless Steel
Seat Disc.................................................................Synthetic Rubber
Return Spring..............................................................Stainless Steel HA7514AP

10
REGO

YEAR
WARRANTY

Ordering Information
Part Number Flow at 1 PSIG Pressure drop GPM Propane
Globe Angle Inlet/Outlet Connection Port Diameter Globe Angle

HA7513AP HA7514AP 2” -FNPT 2” 75.0 88.5

HA7517AP HA7518AP 3”-FNPT 3½” 197.0 303.0

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E15
Flange Seal Globe and Angle Valve Information

General Information Leak-tight performance is assured and periodic adjustment is not


Globe and Angle Valves, incorporating the synthetic rubber flange required. The synthetic rubber construction provides smooth operating
seal design, operate on the same principle as the “V”-ring valves. Gas performance with long service life.
pressure in the valve is exerted against the synthetic rubber flange, These valves all incorporate a plugged ¼” NPT side boss on the
forcing it tightly against the stem. downstream side of the valve that can be equipped with a hydrostatic
relief valve or vent valve.

Please be familiar with the “Installation and Operation Note” and


“Downstream Accessory Boss” section of the “V”-ring valve design
general information before ordering these valves.

Nylon bearing
General Features surrounds stem to
Rugged quick-acting prevent galling.
ACME threads on stem.
Threads are under flange Rubber flange ring
ring . . . dust, sand and grit stem seal effectively
can’t reach them. prevents gas escape.
The higher the
Swivel seat cannot pressure, the tighter
grind during valve the seal.
opening or closing.
Metal to metal back
Synthetic Rubber seat permits
E Seat Disc replacement of
flange ring with
valve in service.

Valve body made of shell molded ductile iron. Highly resistant


to cracking or fracturing from wrenching, dropping or hammer
blows. Bonnet and seal cap are steel on “A” prefix valves.

E16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling
Hoses and Plant Piping 7704, 7705 and 7706 Series

Application
Designed to ensure positive shut-off and long maintenance-free
service life in liquid or vapor service. Ideally suited for use on cylinder
charging manifolds, truck filling hoses, bulk storage containers and
plant piping.

The high quality construction and wide variety of sizes make them
highly suited for use with LP-Gas, anhydrous ammonia and in the
chemical and petrochemical industries.

Features
• Available with either a brass bonnet and bronze stem for LP-Gas
service or a steel bonnet and stainless steel stem for combined
LP-Gas and anhydrous ammonia service.
7704 P
• Flange seal stem provides for leak-proof operation. No packing to A7704 P
retighten or replace. 7705 P
A7705 P
• Metal-to-metal back seat permits replacement of the flange ring
with the valve in service.

• Plugged ¼” NPT boss on downstream side of valve A7704P


accommodates hydrostatic relief valve or vent valve.

• Swivel seat disc minimizes grinding on the body seat and ensures
longer service life.

• “Dropped seat” body design of the angle valve provides high flow
capacity.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar) E

Materials
Body................................................................................ Ductile Iron
Bonnet (7704, 05, 06)............................................................... Brass
Bonnet (A7704, 05, 06)............................................................. Steel 7704 LP
Stem (7704-05-06)................................................................. Bronze A7704 LP
Stem (A7704-05-06)................................................... Stainless Steel 7706 P
Flange Ring............................................................ Synthetic Rubber A7706 P
Seat Disc................................................................ Synthetic Rubber

10
REGO
7706 P

YEAR
WARRANTY

Ordering Information
Part Number Flow at 1 PSIG Pressure Drop (Cv) (GPM/Propane)* Accessories

Globe Angle Inlet & Outlet Connection (F. NPT) Globe Angle Hydrostatic Relief Valve Vent Valve
7704P 7704LP
½” 7.3 12.3
A7704P A7704LP
SS8001J or SS8001L TSS3169
7705P 7706P
¾” 11.5 17.7
A7705P A7706P

* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: A7704LP @ 9 PSIG =12.3 x 9 = 36.9 GPM/propane. For NH3 flow,
multiply propane flow by .90.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E17
Flange Seal Liquid Transfer Angle Valves for Bulk Storage Containers
7550 and 7551 Series

Application
Designed especially for liquid transfer of LP-Gas from consumer bulk
storage containers when used with a Chek-Lok® or equipped with
an integral excess flow valve. May also be used for vapor LP-Gas
service.

In NH3 applicator tanks they may be used as a vapor bleeder valve


or as a liquid withdrawal valve when installed in a coupling with a dip
pipe.

These liquid transfer valves are equipped with an integral excess


flow valve for liquid transfer directly from the tank fitting, or without an
integral excess flow for LP-Gas transfer through a Check-Lok® valve.

When equipped with an integral excess flow valve (7550PX), the


valve should be mounted in a forged steel 3000 lb. half coupling.
When mounted in a 1¼” x ¾” NPT reducing coupling, the ¾” female
thread in this coupling must be full length — equivalent to a forged
steel 3000 lb. half coupling.

The excess flow valve will not function properly if these specifications
are not met. Refer to the Warning Bulletin in the Excess Flow Valve
Section of this catalog.
7550P 7550PX

Features
• Flange seal stem design provides for leak-proof operation. No
packing to retighten or replace.

• Large, unrestricted interior ports reduce pressure drop through the


valve, increasing capacity and preventing cavitation.

• Resilient swivel seat disc ensures longer seat life and easy,
E positive shut-off.

• Plugged ¼” NPT outlet boss accommodates hydrostatic relief


valve or vent valve.

• Specifically designed for liquid transfer of LP-Gas with the Chek-


Lok®.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

Materials
Body (7550, 51)....................................................................... Brass
Body (A7550, 51)................................ Cadmium Plated Ductile Iron
Bonnet (7550, 51).................................................................... Brass
Bonnet (A7550, 51).................................................................. Steel

10
Stem (7550, 51)..................................................................... Bronze REGO
Stem (A7550, 51)...................................................... Stainless Steel
Flange Ring........................................................... Synthetic Rubber
Seat Disc............................................................... Synthetic Rubber
YEAR
WARRANTY

Ordering Information
Excess Flow Accessories
Flow at 1 PSIG (Cv) Approximate
Inlet Connection Outlet Connection Integral Excess Pressure Drop* Closing Flow** Hydrostatic Relief
Part Number (M. NPT) (F. NPT) Flow (GPM/Propane) (GPM/Propane) Valve Vent Valve
7550P 3127U 3165
No 13.3 -
A7550P SS8001J TSS3169
¾”
7550PX 3127U 3165
¾” Yes - 16.0
A7550PX SS8001J TSS3169
7551P 3127U 3165
½” No 8.9 -
A7551P SS8001J TSS3169
* To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop. Example: 7550P @ 9 PSIG = 13.3 x 9 = 39.9 GPM/propane. For NH3 flow, multiple propane flow by .90.
* * For NH3 flow, multiply propane flow by .90.
E18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
High Capacity Liquid Withdrawal Valves For NH3
A8012 Series

Application
The A8012 Series is designed especially for use as a high capacity
liquid withdrawal valve on anhydrous ammonia nurse tanks or risers.

This valve incorporates an integral excess flow valve; when the


valve is in operation the handwheel must be completely open and 0036
back-seated to allow the excess flow valve to function properly as
explained in the excess flow section of our L-500 and L-102 catalogs.

Features
• Excess flow valve designed for high flow and low pressure drop.

• Excess flow seat fully contained in the container coupling for


maximum protection in the event of external damage to the valve.

• Resilient disc assembly with swivel seat is fully contained for


bubble-tight shut-off and long service life.

• “V”- ring spring loaded stem seal design requires no field


adjustment.

• ¼” F.NPT port that accommodates a vent valve or hydrostatic


relief valve.

• UL Listed for LP-Gas and anhydrous ammonia.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

A8012D
E
2.50"
Materials
Body................................................................................. Ductile Iron
Bonnet.............................................................................. Ductile Iron
Stem............................................................................Stainless Steel
Seat Disc................................................................................... Nitrile
“V” –Rings.................................................................................Teflon
Excess Flow Valve.......................................................Stainless Steel
Springs........................................................................Stainless Steel 8.84" 8.84"
2.50" 2.50"

1-1/4" FNPT

2-7/16" HEX

10
REGO
8.84" 8.84" 2.25" 2.25"
TOP OF
CONTAINER

YEAR
1-1/4" FNPT 1-1/4" FNPT
WARRANTY
2-7/16" HEX 2-7/16" HEX

2.25" 2.25"
TOP OF TOP OF
CONTAINER CONTAINER

Ordering Information
Accessories for NH3 Use
Approximate
Part Number Inlet Connection Outlet Connection Closing Flow GPM Hydrostatic Relief Valve Vent Valve
A8012D 72 GPM NH3*
1½” M.NPT 1¼” F.NPT SS8001J TSS3169
A8012C 45 GPM NH3*
* When installed in a horizontally flowing system.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E19
High Capacity Liquid withdrawal Valves for NH3
A8012E

Application
The A8012E is designed especially for use as a high capacity liquid
withdrawal valve on anhydrous ammonia nurse tanks or risers.

This valve incorporates an integral excess flow valve; when the


valve is in operation the handwheel must be completely open and 0036
back-seated to allow the excess flow valve to function properly as
explained in the excess flow section of our L-500 and L-102 catalogs.

Features & Benefits


• Excess flow valve designed for high flow and low pressure drop.

• Excess flow seat fully contained in the container coupling for


maximum protection in the event of external damage to the valve.

• Resilient disc assembly with swivel seat is fully contained for


bubble-tight shut-off and long service life.

• “V”- ring spring loaded stem seal design requires no field


adjustment.

• ¼” F.NPT port that accommodates a vent valve or hydrostatic


relief valve.

• UL Listed for LP-Gas and anhydrous ammonia.

• Meets Illinois Fertilizer & Chemical Association requirement for


excess flow protection.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar) A8012E


E 2.50"

2.50" 2.50"

Materials
Body................................................................................. Ductile Iron
Bonnet.............................................................................. Ductile Iron 8.84" 8.8
Stem............................................................................Stainless Steel
Seat Disc................................................................................... Nitrile
“V” –Rings.................................................................................Teflon
Excess Flow Valve.......................................................Stainless8.84" Steel 8.84"
1-1/4" FNPT

Springs........................................................................Stainless Steel
2-7/16" HEX

1-1/4" FNPT 1-1/4" FNPT

10
2.25" 2.2
TOP OF
R EGO
2-7/16" HEX 2-7/16" HEX CONTAINER

2.25" 2.25"
TOP OF TOP OF
YEAR
CONTAINER CONTAINER
WARRANTY

Ordering Information
Accessories for NH3 Use
Approximate
Part Number Inlet Connection Outlet Connection Closing Flow GPM Hydrostatic Relief Valve Vent Valve
A8012E 1½” M.NPT 1¼” F.NPT 60 GPM NH3* SS8001J TSS3169
* When installed in a horizontally flowing system.

E20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Angled globe with Excess flow
A8014C

Application
The A8014C is designed especially for use as a high capacity
liquid withdrawal valve on anhydrous ammonia nurse tanks or risers.

This valve is mated with an external excess flow valve; when the
valve is in operation the handwheel must be completely open and
back-seated to allow the excess flow valve to function properly as
explained in the excess flow section of our L-500 and L-102 catalogs.

Features & Benefits


• This combo unit gives the control of an angled globe valve with the
safety of an excess flow valve. Predominately aimed at the NH3
market to meet safety requirements set forth in some jurisdictions.

• The excess flow valve shuts off the flow of media in the
event of a hose or piping breakage and prevents loss.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

(Ø3.484)

Materials
A7514AP Angled valve Materials
Body..................................................................................Ductile iron
Stem............................................................................ Stainless steel 7.19 APPROX.
(OPEN)
Seat...................................................................................Ductile iron
Seat Disc................................................................................... Nitrile
Springs........................................................................ Stainless steel
Stem Seals................................................................................ PTFE E
(2-11.5 NPT THD)
Connecting nipple........................................................ Stainless steel
A8014C
A3292C Excess flow valve Materials
Body..........................................................................Cad plated steel
Stem......................................................................... Zinc plated steel
(Ø3.484)
Seat...........................................................................Cad plated steel
Springs........................................................................ Stainless steel
Stem Seals................................................................Cad plated steel (7.400)

7.19 APPROX.
(OPEN)
(2-11.5 NPT THD)

10
REGO
(2.688)
(2-11.5 NPT THD)

YEAR
WARRANTY

(7.400)

(2-11.5 NPT THD)

Ordering Information (2.688)

Approximate Excess Closing Flows


Part Number Inlet Connection Outlet Connection
Liquid (GPM Propane) Liquid (GPM NH3)
A8014C 2” F. NPT 2” M. NPT 122 110

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E21
Multipurpose Valve for Filling of NH3 Containers
A8016DBC

Application
Designed specifically for use as a manual filler valve on anhydrous
ammonia applicator tanks. This valve incorporates an integral back
check valve.

Features
• Positive seating back check valve opens for maximum flow at
minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.

• Back Check seat is fully contained in the tank coupling for


maximum protection in the event of external damage to the valve.

• Resilient seat disc assembly is fully contained on three sides for


bubble-tight shut-off and long service life.

• “V”-ring spring-loaded stem seal design requires no repacking or


field adjustment.

• Specially machined break-away groove beneath ACME threads


will shear-off with excessive pull on the hose and leave the valve
body intact.

• Plugged ¼” NPT boss accommodates vent valve or hydrostatic


relief valve.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)


A8016DBC
• MAWP: 400 PSIG(27 Bar)

Materials
Body............................................................................... Ductile Iron
Bonnet...................................................................................... Steel
“V”-Rings................................................................................. Teflon
Stem.......................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber
Back Check Valve........ Stainless Steel, Steel and Synthetic Rubber
Springs...................................................................... Stainless Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Filling Capacity at 20 PSIG Accessories
Part Number Inlet Connection Filling Connection
Pressure Drop GPM/NH3 Hydrostatic Relief Valve Vent Valve
A8016DBC 1¼” 1¾” 95 SS8001J TSS3169

E22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Multipurpose Valve for Filling of NH3 Containers
A8016DP

Application
Designed specifically for use as a manual valve or vapor equalizing
valve on anhydrous ammonia applicator and nurse tanks.

This valve incorporates an integral excess flow valve. When product


is required, the valve must be completely open and backseated to
allow the excess flow valve to function properly as explained in the
excess flow section of this catalog.

Features
• Positive-acting excess flow valve opens for maximum flow at
minimum pressure drop when filling -- regardless of the type of
coupling in which the valve is installed.

• Excess flow seat is fully contained in the tank coupling for


maximum protection in the event of external damage to the valve.

• Resilient seat disc assembly is fully contained on three sides for


bubble-tight shut-off and long service life.

• “V”-ring spring-loaded stem seal design requires no repacking or


field adjustment.

• Specially machined break-away groove beneath ACME threads


will shear-off with excessive pull on the hose and leave the valve
body intact.

• Plugged ¼” NPT boss accommodates vent valve or hydrostatic


relief valve.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)


A8016DP
• MAWP: 400 PSIG(27 Bar)
E

Materials
Body............................................................................... Ductile Iron
Bonnet...................................................................................... Steel
“V”-Rings................................................................................. Teflon
Stem.......................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber
Excess Flow Valve................................. Stainless Steel--Steel Body
Springs...................................................................... Stainless Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Approximate Excess Flow
Closing Flows Accessories
Inlet Connection Filling Connection Filling Capacity At 20 PSIG Pressure Liquid* Vapor** Hydrostatic
Part Number (M. NPT) (M. ACME) Drop GPM/NH3* GPM/NH3 CFH/NH3 Relief Valve Vent Valve
A8016DP 1¼” 1¾” 95 44 24,000 SS8001J TSS3169
* Determined at 9.5 to 12 PSIG differential.
* * Determined at 100 PSIG inlet.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E23
Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 Containers
A8017D & A8020D

Application
Designed especially for use as a high capacity liquid withdrawal valve
on LP-Gas and anhydrous ammonia containers.

These valves incorporate an integral excess flow valve. When product


is required, the valve must be completely open and backseated to
allow the excess flow valve to function properly as explained in the
excess flow valve section of this catalog.

The A8017DH is equipped with a soft seated automatic differential


back pressure check valve in the seat disc assembly. This allows any
pressure build up in the liquid transfer line in excess of 10-15 psig
above the container pressure to flow back into the container. The
transfer hose is protected against excessive liquid or vapor pressure
entrapment, which adds materially to the useful life of flexible hose.
In addition to increasing hose service life, the equalizing valve adds
substantially to the operating safety of liquid transfer systems.

Features A8017DP
• Positive-acting excess flow valve opens for maximum flow at
minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.
• Excess flow seat is fully contained in the tank coupling for
maximum protection in the event of external damage to the valve.
• Resilient seat disc assembly is fully contained on three sides for
bubble-tight shut-off and long service life.
• “V”-ring spring loaded stem seal design requires no repacking or
field adjustment.
• A8017DH has two plugged ¼” NPT ports, one on the top and the
other on the side, accommodate either a vent valve or hydrostatic
relief valve.
• A8020D has a plugged ¼” NPT port that accommodates vent
E valve, hydrostatic relief valve, or pressure gauge.
• A8017DH incorporates an automatic back check valve built into
the shut-off valve, eliminating the need for a separate hydrostatic
relief valve.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Materials
Body............................................................................... Ductile Iron
Bonnet...................................................................................... Steel
Stem.......................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber
“V”-Rings................................................................................. Teflon
Excess Flow Valve................................ Stainless Steel - Steel Body
Springs...................................................................... Stainless Steel

10
REGO

A8020D

YEAR
WARRANTY

Ordering Information
Accessories
Part Inlet Connection Outlet Connection Approximate Excess Flow Liquid Closing Flow**
Number (M. NPT) (F. NPT) (GPM/Propane) Hydrostatic Relief Valve Vent Valve
A8017DH* 49 Not Required
1”
A8017DP 1¼” 55 TSS3169
SS8001J
A8017DLP ¾” 49
A8020D 1¼” 1” 78 SS8001J TSS3169
* Built-in back pressure check valve incorporated into shut-off valve.
* * Determined at 11.5 to 13.5 PSIG differential for ¾” outlet and 9 to 12 PSIG differential for 1” outlet. For NH3 flow, multiply by .90.

E24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Multipurpose Valve for Filling and Liquid Transfer of NH3 Containers
A8018DP

Application
Designed primarily for use as a combination filler and liquid
withdrawal valve on three-opening applicator tanks or on nurse tanks.

This valve incorporates an integral excess flow valve. When product


is required, the valve must be completely open and backseated to
allow the excess flow valve to function properly as explained in the
excess flow valve section of this catalog.

Features
• Functions as both a filler valve and liquid transfer valve, in one
unit.

• Positive acting excess flow valve opens for maximum flow at


minimum pressure drop when filling — regardless of the type of
coupling in which the valve is installed.

• Excess flow seat is fully contained in the tank coupling for


maximum protection in the event of external damage to the valve.

• Specially machined break-away groove beneath ACME thread of


filler valve will shear-off with excessive pull on the hose and leave
the valve body intact.

• Triple guide filler valve check provides for dependable shut-off


performance when filling ceases. A8018DP
• Resilient seat disc assembly is fully contained on three sides for
bubble-tight shut-off and long service life.

• “V”-ring spring loaded stem seal design requires no repacking or


field adjustment.

• Plugged ¼” NPT boss accommodates vent valve or hydrostatic


E
relief valve.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 400 PSIG(27 Bar)

Materials
Body................................................................................ Ductile Iron
Bonnet....................................................................................... Steel
Stem.......................................................................... Stainless Steel
Seat Discs............................................... Synthetic Resilient Rubber
“V”-Rings................................................................................. Teflon
Excess Flow Valve................................. Stainless Steel - Steel Body
Springs...................................................................... Stainless Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Filling Capacity At Approximate Accessories
Inlet Outlet Filling 20 PSIG Excess Flow
Part Connection Connection Connection Pressure Drop Liquid Closing Hydrostatic Relief
Number (M. NPT) (F. NPT) (M.ACME) GPM/NH3 Flow GPM/NH3 Valve Vent Valve
A8018DP 1¼” 1” 1¾” 74 50 SS8001J TSS3169
* Determined at 9 to 12 PSIG differential.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E25
Multipurpose Filler Bypass Return Valve
8118P and 8117

Application
Designed primarily for use as a Multipurpose valve with combination 0036
filler valve and bypass return with manual shutoff valve for the outlet
connection of the valve for use on LP-Gas containers.

This valve incorporates an integral excess flow valve. When product


is required, the valve must be completely open and back seated to
allow the excess flow valve to function properly as explained in the
excess flow valve section of the RegO L-102 or L-500 catalogs.

Features
• Designed as a filler valve for LP-Gas with upper check and
manual shutoff.

• Excess flow valve allows for maximum filling rates regardless of


the length of the coupling the valve is installed in.

• Excess flow seat is fully contained in the tank coupling for


maximum protection in the event of external damage to the valve.

• Breakaway groove protects the ACME in the case of a drive-away


with the filler hose still connected.

• V-ring spring loaded stem assembly requires no repacking of field


adjustment.

• Plugged ¼” NPT boss allows for a pressure gauge to be installed.

• The one-inch outlet port plugged.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)


E 8118P

Materials
Body........................................................................................ Brass
Inlet Connection...................................................................... Brass
Outlet Connection.................................................................... Brass
Spring........................................................................ Stainless Steel
Seat Disc............................................................... Synthetic Rubber
8117
V-rings..................................................................................... Teflon
Excess Flow Valve..................................................... Stainless Steel

10
REGO

YEAR
WARRANTY

Ordering Information
Filling Capacity at 20
Part Number Container Connection Outlet Connection Filler Connection Plug
PSIG Pressure Drop
8117 ¾” F. NPT No
1¼” M.NPT 1¾” M.ACME 82 GPM
8118P 1” F. NPT Yes
NOTE: Not for use as a permanent vapor connection.

E26 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Adhesive Warning Labels
903-500
The following warning information, Part Number 903-500, is included
Part Number
with each shipment of Quick-Acting and Tank Car Valves to the first
purchaser of the product from the factory. 903-500 Adhesive Warning Label

This information is intended to be forwarded throughout the product


distribution chain. Additional copies are available from RegO and
Authorized Product Distributors.

DANGER READ THIS FIRST WARNING


LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Make sure you are thoroughly trained before you attempt any valve installation, maintenance or repair.
Improper conditions or procedures can cause accidents resulting in property damage and personal injury.
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &
Maintenance” and RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and
“LP-Gas Filler and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve
sections of the L-500 & L-102 Catalogs. Follow their recommendations.
Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is
essential in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed
to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper
handling procedures. Refresher training shall be provided at least every three years and shall be documented.”
Make sure this valve is the proper one for this installation. Avoid misusing LP-Gas equipment.
Apply thread joint compound compatible with LP-Gas on valve external threads only. Make sure compound
never comes into contact with other parts of the valve.
Install valves by applying force to wrenching flats only.
Tighten pipe threads approximately 1 to 1½ turns beyond the hand-tight insertion point using a wrench which
avoids damage to other valve parts.
Check for damage and proper operation after valve installation. Check that the valve is clean and free
of foreign material.
Check container-valve connection with a non-corrosive leak detection solution before filling with LP-Gas.
Purge container before filling with LP-Gas (refer to the RegO LP-Gas Serviceman’s Manual for recommended
procedure).
Test excess flow check valve for proper operation before placing into service. See NPGA Bulletin 113 for
recommended procedure.
Check outlet connection make-up for leaks with a non-corrosive leak detection solution when placing
into service.
RegO Filler Valves: To prevent damage to the internal checks when it is necessary to utilize an unloading
adapter, use ONLY RegO 3119A, 3120 and 3121 Unloading Adapters with RegO Filler Valves. Carefully
follow the instructions supplied with these unloading adapters.
If container is not being placed into service at the present time, insert plug or cap onto the outlet connection.

E
In selecting a label for posting at the installation site, consider RegO part number 901-400 or 903-400 along
with your own, NPGA’s and others.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment.
See RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and “LP-Gas Filler
and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve sections of the
L-500 & L-102 Catalogs.

RegO requests that this information be forwarded to your customers. Additional copies are available from
RegO and your authorized RegO Distributor.
Printed in USA 09A-0910-0686
Part number 903-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

903-500

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO E27
E

E28 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section F
Excess Flow, Check, Filler
and Vapor Equalizing Valves F F

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
F warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

F2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. F
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F3
LP-Gas Excess Flow Valves

Safety Warnings Purpose


In its continuing quest for safety, RegO publishes a series of bulletins explaining the hazards associated with
the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these factual bulletins will make
clear to LP-Gas dealer managers and service personnel, that the utmost care and attention must be used in
the installation, inspection, and maintenance of these products, or problems could occur which would result in
injuries and property damage.

The National Fire Protection Association NFPA 58 Liquefied Petroleum Gas Code - 2020 Edition states in
Section 4.4 Qualification of Personnel; ”Persons whose duties fall within the scope of this code shall be
provided with training that is consistent with the scope of their job activities and that includes proper handling
and emergency response procedures... Refresher training shall be provided at least every 3 years, initial and
subsequent training shall be documented”. These “RegO Safety Warnings” may be useful in training new
employees and reminding older employees of hazards that can occur. It is recommended that all employees
complete the Propane Education Research Council’s Certified Employee Training Program.

Nature of Warnings RegO provides excess flow valves with a number of closing ratings.
It is recognized that warnings should be as brief as possible, but RegO obviously can take no responsibility for the proper selection or
the factors involved in excess flow valve failures to perform are not correct installation of any valve.
simple. They need to be fully understood. If there is a simple warning,
it would be: Excess flow valves do not provide complete shut-off because there is
a bleed at the check to permit pressure equalization.
Make sure that the excess flow valve really closes when
the flow exceeds normal transfer flow. Causes of Failure to Close
Installers, LP-Gas plant managers and service personnel should be
This bulletin is not intended to be an exhaustive treatment of excess
aware that the excess flow valves may not close if these conditions
flow valves, and certainly does not cover all safety practices that
are present.
should be followed in installation, operation and maintenance of
LP-Gas systems which include excess flow valves.
1. The piping system restrictions (due to pipe length, branches,
reduction in pipe size or number of other valves) decrease the
Selection and Installation flow rate to less than the valve’s closing flow.
The selection of a given closing rating of an excess flow valve
F involves an analysis of the complete piping system and is beyond the
scope of this bulletin.

It is sufficient to say that an excess flow valve must be installed in


the correct direction and will close only if the flow of liquid or vapor
exceeds its designed closing rating. Many valves have been installed
with closing ratings considerably higher than any flow that could be
obtained by a downstream rupture in piping or hoses and thus give
none of the protection for which they are intended.

F4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
LP-Gas Excess Flow Valves

2. The break or damage to the downstream line is not Because of these limitations, it is good industry practice to NOT
large enough to allow enough flow to close the valve. rely entirely on excess flow valves for protection. Installation of
emergency shut-off valves with remote controls is recommended in
addition to excess flow valves.

Testing
The National Propane Gas Association Safety Bulletin #113-78
states:

“In order to test an excess flow valve in a piping system, the


flow through the valve must be made to exceed the valve’s
closing rating. This testing should only be attempted by trained
3. A shut-off valve in the line is only partially open and will personnel familiar with the process. If no one at the facility
not allow enough flow to close the excess flow valve. has experience in proper testing, outside expert help should
be obtained. The exact procedure used may vary with the
installation, advisability of gas discharge and availability of
equipment.

In general, most testing makes use of the fact that excess flow valves
are “surge sensitive” and will close quicker under a sudden flow surge
than under steady flow. A sufficient surge can often be created by
using a quick open/close valve to control sudden, momentary flow
into a tank or piping section containing very low pressure. An audible
click from the excess flow valve (and corresponding stoppage of flow)
indicates its closure.

A test involving venting gas to the atmosphere is hazardous


and may be impractical, or illegal.

Any test of any excess flow valve will not prove that the valve will
close in an emergency situation, due to reasons cited before. This
test will only check the valve’s condition, and the flow rate sizing for
those test conditions.” F

4. LP-Gas pressure upstream of the excess flow valve, General Warning


particularly due to low temperature, is not high All RegO products are mechanical devices that will eventually
enough to produce a closing flow rate. become inoperative due to wear, contaminants, corrosion and aging
of components made of materials such as metal and rubber.

The environment and conditions of use will determine the safe service
life of these products. Periodic testing at least once a year when tank
pressures are low and maintenance, as required, are essential.

Because RegO products have a long and proven record of quality


and service, LP-Gas dealers may forget the hazards that can occur
because an excess flow valve is used beyond its safe service life. Life
of an excess flow valve is determined by the environment in which
it “lives”. The LP-Gas dealer knows better than anyone what this
environment is.

NOTE: There is a developing trend in state legislation and


in proposed national legislation to make the owners of products
responsible for replacing products before they reach the end of their
safe useful life. LP-Gas dealers should be aware of legislation which
5. Foreign matter could effect them.
(such as welding
slag, scale or
sludge) is lodged
in the valve and
prevents closing.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F5
Troubleshooting Excess Flow Valve Installations

Periodical Inspections for Excess Flow Valves 2. Line Restriction Too Great
An excess flow valve installed
Excess flow valves should be tested and proven at the time of in a tank outlet will not close if
installation and at periodic intervals not to exceed one year. the line beyond it is reduced or
CAUTION: Testing an excess flow valve in the summer when if the flow is otherwise restricted
tank pressures are high will not prove that the same valve will by too many fittings or too
also function under low pressure conditions in the winter. Once long a run because the line is
a year testing should be conducted during the winter. incapable of passing the amount
of LP-Gas necessary to create
The test should include a simulated break in the line by the quick an “excess” flow. This condition
opening of a shut-off valve at the farthest point in the piping that should be corrected when testing
the excess flow valve is intended to protect. If the excess flow valve a system by simulating a break
closes under these conditions, it is reasonable to assume that it will at the farthest possible point and
close in the event of accidental breakage (clean break) of the piping replacing any restrictive hose,
at any point closer to the excess flow valve. pipe or fittings.

The National Propane Gas Association Safety Bulletin Number 113- 3. Improper Operating Practice
78 states:
A restriction can also be imposed
In order to test an excess flow valve in a piping system, the upon the excess flow valve by an
flow through the valve must be made to exceed the valve’s improperly opened valve at the
closing rating. This testing should only be attempted by trained tank outlet. The shutoff valve
personnel familiar with the process. If no one at the facility should be either fully opened
has experience in proper testing, outside expert help should or fully closed. If “throttled,” the
be obtained. The exact procedure used may vary with the valve could reduce the amount
installation, advisability of gas discharge and availability of of LP-Gas passing through the
equipment. excess flow valve in a sufficient
amount to keep it from closing.
In general, most testing makes use of the fact that excess flow valves Throttling operations should not
are “surge sensitive” and will close quicker under sudden flow surge be performed in the lines being
than under steady flow. A sufficient surge can often be created by protected by excess flow valves.
using a quick open/close valve to control sudden, momentary flow
4. Improper Selection
F into a tank or piping section containing very low pressure. An audible
click from the excess flow valve (and corresponding stoppage of flow) The many types of excess flow
indicates its closure. valves available are designed for
specific jobs. The excess flow
A test involving venting gas to the atmosphere is hazardous valve selected should remain
and may be impractical or illegal. open during normal flow but close
Any test of any excess flow valve will not prove that the valve will at “excess” flow. An inspection
close in an emergency situation, due to reasons cited before. This which simulates a line break
test will only check the valve’s condition and the flow rate sizing for prior to start-up operations will
those test conditions. determine if the proper valve has
been selected.
What prevents excess flow valves from closing when the line
breaks? 5. Tampering with Excess Flow Valves

Sometimes an operator, annoyed


For one or a combination of the following reasons, excess flow valves
with frequent closures of an
have been prevented from closing in emergencies:
excess flow valve with too low
a rating, has mutilated the valve
and forgotten to replace it with a
properly rated excess flow valve.
A pre-test of the system would
1. Not a Clean Break reveal this and allow the excess
flow valve to be replaced.

Hoses with a split or tear, and


6. Impurities in the Line
pipe lines not completely severed
may be emitting LP-Gas in an
amount insufficient to cause Dirt, weld slag, broken drill
an “excess” flow. The amount taps, and various other foreign
of LP-Gas which can escape objects have been found jammed
through such breaks may be even between the valve disc and valve
less than the flow during normal seat to prevent excess flow
transfer service and under these valves from closing. A pre-test of
conditions the excess flow valve the system would also discover
could not be expected to close. this.

F6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
The Limitations of Excess Check Valves for LP-Gas

Excess flow check valves have been of help in limiting gas loss in Where excess flow valves are installed, they should be checked
many incidents involving breakage of hoses and transfer piping. to see that:
Thus, they do provide a useful safety function in LP-Gas systems.
However, there have also been transfer system accidents where 1. They are installed in the correct direction — the arrow on the
excess flow valves have been ineffective in controlling gas loss due to valve indicates the shut-off direction.
a variety of conditions and to the inherent limitations of these valves.
This bulletin explains what protection excess flow valves can offer, 2. The flow rating on the valve is proper for the installation. The
points out conditions which can interfere with that protection, and rating must be above the normal system flow, but not higher than
offers suggestions for effective excess flow valve installation. necessary to prevent “nuisance” closing in normal conditions. If
the manufacturer’s catalog information is not sufficient, the valve
An excess flow valve is a protective device to help control the suppliers can provide sizing assistance.
discharge of product in the event of complete breakage of pipe lines
or hose rupture. However, an excess flow valve can only offer limited 3. In-line excess flow valves are installed so likely piping damage
protection from gas discharge, because it will only close under those will occur downstream of the valve and will not separate the
conditions which cause the flow through the valve to exceed its rated
valve from the upstream piping.
closing flow, and even when closed it necessarily allows some “bleed”
past the valve. When the excess flow valves can be examined separate
from the line (before the installation or if removed for system
An excess flow valve is not designed to close and thus may not maintenance), they should be checked to see that the parts are
provide protection, if any of the following conditions are present: in good condition and that the poppet can be pushed fully closed.
1. The piping system restrictions (due to pipe length, branches,
Testing of Excess Flow Valves
reduction in pipe size, or number of other valves) decrease the
flow rate to less than the valve’s closing flow. (Valve should be
In order to test an excess flow valve in a piping system, the flow
selected by closing flow rating — not just by pipe size). through the valve must be made to exceed the valve’s closing
rating.
2. The break or damage to the downstream line is not large enough to
allow enough flow to close the valve. This testing should only be attempted by trained personnel
familiar with the process. If no one at the facility has experience
3. A shut-off valve in the line is only partially open and will not allow in proper testing, outside expert help should be obtained. The
enough flow to close the excess flow valve. exact procedure used may vary with the installation, advisability

4. LP-Gas pressure upstream of the excess flow valve, particularly


of gas discharge, and availability of equipment. F
due to low temperature, is not high enough to produce a closing In general, most testing makes use of the fact that excess flow
flow rate. valves are “surge sensitive” and will close quicker under a
sudden flow surge than under steady flow. A sufficient surge can
5. Foreign matter (such as welding slag) is lodged in the valve and often be created by using a quick-closing valve to control sudden,
prevents its closing. momentary flow into a tank or piping section containing very
low pressure. An audible click from the excess flow valve (and
6. A buildup of process material (sludge), which may be found in corresponding stoppage of flow) indicates its closure.
LP-Gas, may occur over a period of time and cause the valve to
stick open. A test involving venting gas to the atmosphere is hazardous and
may be impractical, or illegal.
7. The piping break or damage occurs upstream of an in-line excess
flow valve, so the escaping product is not passing through the Any test of any excess flow valve will not prove that the valve
valve. will close in an emergency situation, due to reasons cited before.
This test will only check the valve’s condition, and the flow rate
sizing for those test conditions.
8. The flow through the valve is in the wrong direction. (Excess flow
valves only respond to flow in one direction.)
For additional information on excess flow valves and other means
of shut-off protection, contact RegO and refer to NFPA 58.
9.The excess flow valve has been damaged, or is otherwise not in
operating condition.

Because of these limitations of excess flow valves, they should not Prepared by
be relied upon as the only means of controlling the escape of product NATIONAL PROPANE GAS ASSOCIATION
in the event of piping damage. When possible, shut-off protection by The purpose of this bulletin is to set forth general safety practices for
quick closing valves, with shut-off controls accessible in spite of likely the installation, operation, and maintenance of LP-Gas equipment.
line damage, should be provided in addition to, or instead of excess It is not intended to be an exhaustive treatment of the subject, and
flow valves. should not be interpreted as precluding other procedures which
would enhance safe LP-Gas operations. The National Propane Gas
Association assumes no liability for reliance on the contents of this
bulletin.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F7
Excess Flow Valves

General Information How They Work


RegO Excess Flow Valves have been designed, developed, and Excess flow valves permit the flow of liquid or vapor in either direction.
manufactured for a wide variety of industry needs for more than three This flow is controlled in only one direction (the direction of the arrow
decades. stamped on the valve). If the flow in that direction exceeds a
predetermined rate (shown in this catalog for each valve), the valve
Throughout the years, those concerned with installing and operating automatically closes.
bulk plant facilities have looked to RegO products with confidence
for reliable, long-lasting valves as required by the National Fire The valve disc is held in the open position by a spring. When the
Protection Association (NFPA) Standards 58 and 59, as well as any flow creates a pressure drop across the valve disc that overcomes
state, provincial, and local regulations. the preset load on the spring, the valve disc moves to the closed
position. It remains closed until the force on both sides of the valve
It is a responsibility we have not taken lightly. RegO products disc are approximately equal (a small bleed hole in the disc of each
continue to not only assess the most effective designs, but anticipate valve permits equalization), then the spring automatically reopens
and meet the industry’s changing requirements. Toward that goal, the valve. When a line is completely broken, the pressure cannot
RegO products include over fifty different types and sizes of excess equalize and the excess flow valve remains closed until the line
flow valves (most of which are listed by Underwriters Laboratories) to is repaired. Because the bleed hole in each valve disc permits
meet the needs of the LP-Gas and anhydrous ammonia industries. equalization of pressure, excess flow valves do not provide a 100
percent type shut-off.
An Explanation and Warning
An excess flow valve is a spring-loaded check valve which will close Proper Installation
only when the flow of fluid through the valve generates sufficient force Since excess flow valves depend on flow in order to close, the line
to overcome the power of the spring holding it open. Each valve has downstream of the excess flow valve should be large enough not
a closing rating in gallons per minute and CFH/air. to excessively restrict the flow. If the piping is too small, unusually
long or restricted by too many elbows, tees and other fittings,
consideration should be given to the use of larger size pipe fittings.
The selection of a proper closing rating is critical. It requires a
technical understanding of the flow characteristics of the piping An excess flow valve in a pump suction line cannot be expected to
system, including restrictions of the piping and other valves and close in the case of a clean break in the line beyond the pump, as the
fittings downstream of the excess flow valve. pump constitutes too great a restriction, even if running.

Good piping practices dictate the selection of an excess flow valve


System designers and operating people must understand why an with a rated closing flow of approximately 50 percent greater than the
F excess flow valve, which remains open in normal operations, may fail
to close when an accident occurs.
anticipated normal flow. This is important because valves which have
a rated closing flow very close to the normal flow may chatter or slug
closed when surges in the line occur during normal operation, or due
to the rapid opening of a control valve.
Warning: A downstream break in piping or hoses may not
result in sufficient flow to close the valve. All installations must be in accordance with NFPA Standards 58 and
59, as well as state, provincial and local regulations.

Cotter pin prevents loss of


spring retainer due to vibration
in service.

Spring retainer.

Stainless steel spring for


consistent closing flow, long
service life.

Welded for strength.

Precision machining.

Generous flow channels for


lowest pressure drop are
particularly important in pump
suction lines.

F8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Valves for Liquid or Vapor Service
1519C Series

Application
Designed for top mounting in storage tank manhole covers for liquid
or vapor applications. The tapped inlet allows for an optional 1” NPT
dip pipe connection to withdraw liquid from the top of the tank.

The 1519C4 is designed for installation in long line or branch piping


applications.

Features
• Precision machined
• Generous flow channels provide low pressure drop.
• Cotter pin prevents loss of spring retainer due to vibration in service.
• Stainless steel spring provides consistent closing flow and long
service life.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

Materials
1519C2
Body........................................................................................ Brass
Valve Poppet w/Stem.............................................................. Brass
Spring........................................................................ Stainless Steel
Guide....................................................................................... Brass

1519C4
Body........................................................................................ Brass
Valve Disc...................................................... Cadmium Plated Steel
Stem.......................................................................... Stainless Steel Typical Installation
Spring........................................................................ Stainless Steel 1519C2
Guide.............................................................................. Ductile Iron
F
Manhole Cover

10
REGO

1519C4
YEAR 1519C4
WARRANTY

Typical Installation
Ordering Information
Approximate Closing Flows**
A B D
Inlet Outlet C Effective E Vapor SCFH (Propane)
Connection Connection Wrench Hex Length Threaded End to Liquid
Part Number NPT F. NPT Flats (Approx.) Port (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
1519C2 1½” Male* 1” 2¼” 21⁄16” 211⁄16” 25 5,000 8,800
1519C4 2” Female 2” 3” 49⁄16” - 170 28,590 48,600

* 1” Female Dip Pipe Connection


** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.
100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F9
Excess Flow Valves for Liquid or Vapor Line Service
1519A Series, 1519B Series and A1519 Series

Application
Designed for top installation, in any position, in liquid or vapor service
lines. They are intended for long lines or branch piping where tank
mounted excess flow valves cannot suffice.

Features
• Precision machined.

• Generous flow channels provide low pressure drop.

• Cotter pin prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar) 1519A2, 1519A3, 1519A4, 1519B4,


A1519A2, A1519A4, A1519B4

Materials
1519A Series and 1519B Series
Body........................................................................................ Brass
Valve Poppet w/Stem.............................................................. Brass
Spring........................................................................ Stainless Steel
Guide....................................................................................... Brass

A1519 Series
Body.............................................................. Cadmium Plated Steel
Valve Disc...................................................... Cadmium Plated Steel
F Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
Guide.............................................................................. Ductile Iron

A1519A6

Typical Installation

10
REGO

YEAR
WARRANTY

NOTE: Multiply flow rate by .94 to determine liquid butane flow


Ordering Information and by .90 to determine liquid anhydrous ammonia flow.

Approximate Closing Flows*


A B D
Brass Inlet Outlet C Effective Vapor SCFH (Propane)
or Connection Connection Wrench Hex Length Liquid
Part Number Steel NPT F. NPT Flats (Approx) (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
1519A2 Brass
1” 1” 1¾” 3⁄ ”
9 16 25 5,000 8,800
A1519A2 Steel
1519A3 1½” 1½” 2¼” 4” 60 11,500 20,200
Brass
1519A4
413⁄16” 100 19,000 34,500
A1519A4 Steel
2” 2” 3”
1519B4 Brass 49⁄16”
133 27,700 50,300
A1519B4 413⁄16”
Steel
A1519A6 3” 3” 4” 627⁄32” 225 45,000 82,000
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

F10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Valves for Liquid or Vapor 3272 Series, 3282 Series, 3292
Series, A3272 Series, A3282 Series, A3292 Series, 7574 and 12472

Application
Designed for liquid or vapor use for filling, withdrawal and vapor
equalizing in container or line applications. They are intended for long
lines or branch piping where tank-mounted excess flow valves are
inadequate.

Features
• Precision machined.
• Generous flow channels provide low pressure drop.
• Stainless steel spring provides consistent closing flow and long
service life.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

Materials
Series 3272, 3282, 3292, 7574, 12472
Body........................................................................................ Brass
Seat Disc................................................................................. Brass 3282A
Stem........................................................................................ Brass
Spring........................................................................ Stainless Steel
Typical Installation
Guide (12472 ONLY).............................................................. Plastic

Series A3272, A3282, A3292


Body.............................................................. Cadmium Plated Steel
Seat Disc....................................................... Cadmium Plated Steel
Stem.............................................................. Cadmium Plated Steel
Spring........................................................................ Stainless Steel
Container Service Pipe Line Service
Performance
500
60
50 Closing Flow Range 400
Closing Flow Range
40 A- 12472 E - 3282A G 300
B- 3272E F - 3282B A - 3292A

F
F
B - 3292B

10
30 C- 3272F G - 3282C
D- 3272G A3282C 200 A3292B
REGO
E
20 A3272G C - 7574
D Pro p ane Flo w (GPM )
Pro p ane Flo w (GPM )

C 100
90
10 80 B
9 70 C
8 B
7 60 A

YEAR
6 50
5
4 40

WARRANTY 3
A 30

20
2

1 10
.07.08.09.1 .2 .3 .4 .5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 910 .07.08.09 .1 .2 .3 .4 .5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 9 10
Drop Across Valve (PSI) Drop Across Valve (PSI)

Ordering Information NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

B D Approximate Closing Flow*


A Outlet C Effective Vapor SCFH (Propane)
Part Brass or Inlet Connection Connection Wrench Length
Number Steel (M. NPT) (F. NPT) Hex Flats (Approx.) Liquid (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
12472 17⁄16” 4 1,050 1,700
Brass
3272E 15⁄16”
10 2,100 3,700
A3272E Steel 13⁄8”
3272F Brass 15⁄16”
¾” ¾” 1⅜” 15 2,800 5,000
A3272F Steel 13⁄8”
3272G Brass 15⁄16”
20 3,700 6,900
A3272G Steel 13⁄8”
3272H 15⁄16” 29 NA NA
Brass
3282A
30 5,850 10,000
A3282A** Steel
17⁄16”
3282B 1¼” 1¼” 2” 40 7,600 13,600
Brass
3282C
50 9,000 16,300
A3282C Steel 15⁄8”
7574 90 15,200 28,100
1½” 1½” 2¼” 17⁄8”
7574L Brass 70 14,000 25,000
3292A 2⅞”
75 14,200 24,800
A3292A Steel 3”
3292B Brass 2⅞”
2” 2” 2” 100 18,100 32,700
A3292B
A3292C Steel 3” 122 22,100 37,600
A3292D** 160 NA NA
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
**Not UL Listed
100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F11
Excess Flow Valve for Autogas Dispensing Systems
3272H

Application
Especially designed for high flow/high differential dispensing
systems. Can also be used for filling, liquid withdrawal, and vapor
equalizing in container or line applications.

Features
• Solid brass construction

• Stainless steel spring

• Meets UL requirements

• Highest flowing valve in the market

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Materials
Body.......................................................................................... Brass
Spring..........................................................................Stainless Steel
Seat........................................................................................... Brass

3272H

¾
Typical Installation

Container Service Pipe Line Service 1


/16

10
REGO

¾
YEAR
WARRANTY

Ordering Information
Part Effective Length Liquid
Number Inlet Connection Outlet Connection Wrench Hex Flats (Approx.) (GPM Propane)
3272H ¾” ¾” 1⅜” 1⅜” 29

F12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Valves for Container Service
A7537 Series, A7539 Series, A8523 and A8525

Application
Designed for mounting in threaded full or half couplings in container
installations. They may be used for filling, withdrawal or vapor
equalizing applications. The exceptionally low pressure drop makes
them ideal for pump suction lines. If a riser pipe to the vapor space is
used with these valves, the minimum inside diameter of the riser pipe
must be at least two times the valve thread size in order not to restrict
flow to the side inlet ports.

Features
• Precision machined.

• Generous flow channels provide low pressure drop minimizing


cavitation in pump suction lines.

• Cotter pin prevents loss of spring retainer due to vibration in service.

• Stainless steel spring provides consistent closing flow and long


service life.

• Separate models for installation in either half or full couplings.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)


A7537N4
• MAWP: 250 PSIG(17 Bar)
Typical Installation
Materials
Body.............................................................. Cadmium Plated Steel
Body (A7539 Series Only).............................................. Ductile Iron
Seat Disc....................................................... Cadmium Plated Steel
Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
Guide............................................................. Cadmium Plated Steel Half Coupling Full Coupling F

10
REGO

YEAR
WARRANTY

NOTE: Multiply flow rate by .94 to determine liquid butane flow and
Ordering Information by .90 to determine liquid anhydrous ammonia flow.

B Approximate Closing Flow*


A Outlet D Vapor SCFH (Propane)
Part For Use With This Inlet Connection Connection C Effective Length Liquid (GPM
Number Type Coupling M. NPT NPT Wrench Hex Flats (Approx.) Propane) 25 PSIG Inlet 100 PSIG Inlet
A8523 Half ¾” ¾” Male 1⅛” 1¾” 15 5,170 8,800
A8525 Half 1¼” 1¼” Male 1¾” 2⅛” 35 12,540 21,560
A7537L4 Half
75 13,000 25,600
A7537L4F Full
A7537N4 Half 2” Male
2” and 2⅝“ 2½” 125 25,000 42,500
A7537N4F Full 1¼” Female
A7537P4 Half
150 30,500 52,000
A7537P4F Full
A7539R6 Half
150 32,100 55,500
A7539R6F Full
A7539T6 Half 3” Male
3” and 3¾” 3⅛” 200 39,400 68,300
A7539T6F Full 2” Female
A7539V6 Half
250 51,100 88,700
A7539V6F Full
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F13
Excess Flow Valves for Vapor or Liquid
A2137 Series and 2139 Series

Application
Designed especially for filling, withdrawing or vapor equalizing in
half and full coupling installations. Ideal for container service where
welded-in dip pipes are not provided. For vapor use, mount in the
bottom opening with a threaded dip pipe. For liquid use, mount in the
top opening with a threaded dip pipe. These may also be installed in
pipe lines provided the connection is made to the male inlet thread
and not the female dip pipe connection.

Features
• Precision machined.

• Cotter pin helps prevents loss of spring retainer due to vibration in


service.

• Stainless steel spring provides consistent closing flow and long


service life.

• Generous flow channels provide low pressure drop.

• Temperature range of -40°F to +165°F. (-40°C to +73°C) A2137


Typical Installations
• MAWP: 250 PSIG(17 Bar)

Materials
A2137 Series
Body.............................................................. Cadmium Plated Steel
Disc................................................................ Cadmium Plated Steel
Stem.......................................................................... Stainless Steel Container Service Pipe Line Service
Spring........................................................................ Stainless Steel
F Guide............................................................. Cadmium Plated Steel

2139 Series
Body........................................................................................ Brass
Disc.......................................................................................... Brass
Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
Guide....................................................................................... Brass

10
REGO

YEAR
WARRANTY

NOTE: Multiply flow rate by .94 to determine liquid butane flow


and by .90 to determine liquid anhydrous ammonia flow.

Ordering Information
Approximate Closing Flows***
A B D Vapor SCFH (Propane)
Inlet Connection Outlet Connection C Effective Length Liquid
Part Number NPT F. NPT Wrench Hex Flats (Approx.) (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
A2137 2” Male and 1¼” 50 10,000 17,000
2”* 27⁄16” 19⁄16”
A2137A Female 70 14,000 25,000
2139 3” Male and 2” 125 26,500 46,000
3”** 3½” 13⁄4”
2139A Female 160 32,700 57,200

* 1¼” F. NPT Dip Pipe Connection


** 2” F. NPT Dip Pipe Connection
*** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

F14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Valves for Flange Mounting in Container Service
A3500 Series and A4500 Series

Application
Designed for mounting in flanged tank connections with internal
threads in the bottom of a container. They may be used in filling,
withdrawal or vapor equalizing application. They provide high flow
capacity with low pressure drop to minimize pump inlet line cavitation.

If a riser pipe to the vapor space is used with these excess flow
valves, the minimum inside diameter of the riser pipe must be at least
two times the valve thread size in order not to restrict flow to the side
inlet ports.

Flange mounted excess flow valves are readily accessible for


servicing and completely enclosed and protected in event of fire.
Because there is no direct connection between external piping and
the valve, stresses imposed on piping will not affect the excess flow
valve.
A3500L4
Features
• Precision machined.
• Generous flow channels provide low pressure drop minimizing
cavitation in pump suction lines.
• Cotter pin prevents loss of spring retainer due to vibration in
service.
• Stainless steel spring provides consistent closing flow and long
service life.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

Materials
Body.............................................................. Cadmium Plated Steel
Seat Disc....................................................... Cadmium Plated Steel
Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
F
Guide............................................................. Cadmium Plated Steel

Flanged Installation In Container


NOTE: The opening in the tank flange should be machined with a
¼”-45° chamfer at the outer edge. The thread should be tapped
one or two turns large as checked by a plug gauge. This and the

10
undersize thread on the valve should permit the valve to be installed REGO
so that its outer face is at least flush with the outer edge of the flange.

The valve is screwed into this opening by fitting a ¼” flat metal piece
into the slot and turning until hand tight. A lubricant may be used, but YEAR
a luting compound is not necessary since this joint does not have to WARRANTY
be gas tight.

If any difficulty is experienced in “making up” the valve to fit flush, as


indicated, the thread in the tank flange can be tapped.

Design and construction of tank and flange must be in accordance


with the appropriate section of the ASME Pressure Vessel Code.
A3400L4, A3400L6,
Ordering Information A3500L4, A3500R6,
Key A3500N4, A3500T6,
Approximate Closing Flows* No. Description A3500P4 A3500V6 A4500Y8
Vapor SCFH A Valve Size (NPT) 2” 3” 4”
A C D (Propane)
Inlet B Effective Threaded Liquid B Tank Opening 3½” 4½” 5½”
Part Connection For Thread End To (GPM 25 PSIG 100 PSIG Liquid C Thickness (min.) 1” 1¼” 13⁄8”
Number NPT Installation (Approx.) Port Propane) Inlet Inlet (GPM NH3) D Outside Diameter 6½” 8¼” 10”
A3500L4 75 13,000 22,500 70 E Pipe Thread (NPT) 2” 3” 4”
A3500N4 2” ¾” 115⁄16” 125 25,000 42,500 115 Bolt Circle Dia. 5” 65⁄8” 77⁄8”
F
A3500P4 150 30,500 52,000 Number of Bolt Holes 8 8 8
Slotted 135
A3500R6 150 32,100 55,500 5⁄8” -11
¾” - 10 ¾” - 10
Body G Bolt Hole Thread
A3500T6 3” 1” 1⁄ ”
9 16 200 39,400 68,300 180 NC - 2 NC - 2 NC - 2
A3500V6 250 51,100 88,700 225 Bolt Hole Thread
H ¾” 1” 1⅛”
A4500Y8 4” 11⁄16” 115⁄16” 500 89,000 154,000 450 (min. eff.)

NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F15
Excess Flow Valves for Liquid or Vapor Withdrawal
2723C and A8013D Series

Application
These valves are designed for bottom mounting in consumer storage
tanks for liquid service. They may also be top mounted for vapor
service. These valves are designed especially for use with RegO
globe and angle valves.

Features
• 2723C provides a ¾” dip pipe inlet connection for top-mounted
liquid or bottom-mounted vapor requirements.

• A8013D Series features a 2-position floating valve disc for faster,


more efficient container filing.

• Precision machined.

• Stainless steel spring provides consistent closing flow and long


service life.

• Generous flow channels provide low pressure drop.


A8013D
• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Materials
A8013D Series
Body.............................................................. Cadmium Plated Steel
Disc............................................................................ Stainless Steel
Stem.......................................................................... Stainless Steel
Spring........................................................................ Stainless Steel
F Guide............................................................. Cadmium Plated Steel
Insert......................................................................... Stainless Steel
2723C
Body........................................................................................ Brass
Valve Poppet........................................................................... Brass
Retainer................................................................................... Brass
Spring........................................................................ Stainless Steel
2723C

Typical Installation Container Service

10
REGO

YEAR
WARRANTY

2723C A8013D

Ordering Information
A. B. D. Approximate Closing Flow**
Inlet Outlet C. Effective E. Vapor SCFH (Propane)
Connection Connection Wrench Hex Length Threaded End Liquid
Part Number M. NPT NPT Flats (Approx.) To Port (GPM Propane) 25 PSIG Inlet 100 PSIG Inlet
A8013D ¾” 13⁄32” 39
8,700 14,700
A8013DA 1¼” 1” 1¾” 13⁄16” - 44
A8013DB 1¼” 17⁄32” 55 10,900 19,300
2723C 1¼” ¾” 111⁄16” 15⁄16” 115⁄16” 20 3,900 6,900
* ¾” F. NPT Dip Pipe Connection
** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

F16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Valve for Pressure Gauges
2884D

Application
Designed for container use in pressure gauge installations to minimize
excess gas discharge in the event the pressure gauge is sheared. A E
suitable shut-off valve should be installed between this valve and the A
pressure gauge to allow convenient gauge replacement.
Features D
• Precision machined.
• Suitable for use with all ¼” M.NPT pressure gauges. C
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
B
• MAWP: 250 PSIG(17 Bar)

10
Materials REGO
Body........................................................................................ Brass
Valve ....................................................................................... Brass
Spring........................................................................ Stainless Steel
YEAR
Pin Stainless Steel
2884D WARRANTY
Ordering Information
Approximate Closing Flow*
Vapor SCFH (Propane)
A. B. D. E.
Part Inlet Connection Outlet Connection C. Effective Length Threaded End To Liquid 100 PSIG
Number M. NPT F. NPT Wrench Hex Flats (Approx.) Port (GPM Propane) 25 PSIG Inlet Inlet
2884D ¾” ¼” 11⁄16” ⁄ ”
11 16 ⁄ ”
15 16 N/A 60 110
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.

Excess Flow Valve for DOT Cylinders


3199W
F
Application
Designed for use on portable systems with vapor or liquid including torches,
heaters, lead melting burners, tar and asphalt burners, wallpaper steamers and
other applications involving portable DOT cylinders. The POL inlet attaches
directly to the cylinder valve and the outlet mounts to the regulator.

3199W
Features
• Integral ball check design. A C
B
• Machined groove designed to break-off and allow excess flow
valve ball to close.
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)
D
Materials
Body........................................................................................ Brass Groove
Nut........................................................................................... Brass
Bell............................................................................ Stainless Steel
Spring........................................................................ Stainless Steel
Typical Installation
Retainer Spring......................................................... Stainless Steel
Retainer................................................................................... Brass

10
REGO NOTE:
No protection is afforded should break-off occur downstream of the
groove. Also, restrictions introduced by the regulator may prevent
closing of the valve due to limited flow capacity. The valve’s purpose
YEAR is to protect the cylinder valve outlet should the regulator be broken
WARRANTY off of its connection (at the groove), in which case it will close. It must
not be depended upon to protect against breaks downstream of the
regulator.
Ordering Information
Approximate Closing Flow*
Vapor SCFH (Propane)
D.
Part A. B. C. Effective Length Liquid
Number Inlet Connection Outlet Connection Wrench Hex Flats (Approx.) (GPM Propane) 100 PSIG Inlet
3199W Male POL ¼” ⅞” 27⁄16” .95 575
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
NOTE: Multiply flow rate by .94 to determine liquid butane flow.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F17
Chek-Lok® Excess Flow Valves

Designed to provide a convenient means of withdrawing liquid from The Chek-Lok® permits one transfer shut-off valve with an adapter
stationary containers prior to moving the container. to be used interchangeably on a number of tanks. With a Chek-Lok®
on each tank and a high capacity RegO 7550P Series transfer valve
NFPA Pamphlet 58 standards require: 1) containers with 125 gallons
and adapter on all your service and delivery trucks – the need for
water capacity, or more, have a connection for liquid evacuation which
individual transfer valves is eliminated. This provides a substantial
is at least ¾” NPT, and 2) containers designed for stationary use, have
savings without sacrificing safety.
no more propane than 5% of their water capacity in liquid form during
transportation. These rules apply to containers manufactured after
July 1, 1961.
Chek-Lok® Operation

Instructions to Open Chek-Lok®


1 Loosen cap to vent any accumulated LP-Gas from the Chek-Lok.
After venting stops, remove the cap. If venting does not stop, Connecting the 7590U or
retighten the cap and use other approved means to withdraw
liquid from the container. 7591U Chek-Lok®
NOTE: Use a suitable size wrench when removing the cap
and adapter from the Chek-Lok. Do not allow the Chek-Lok to
7550P Angle Valve
un-thread from the tank during removal. When necessary, use a
second wrench to secure the Chek-Lok in position.
2 Before beginning withdrawal, securely connect a RegO 7550P
angle valve or suitable shut-off valve to the adapter. Fully open
the shut-off valve – the valve’s handwheel must be fully opened
before connecting adapter to tank.
7590U-10 Adapter
3 Completely thread the adapter and shut-off valve assembly onto
the Chek-Lok by turning adapter’s coupling nut clockwise until it
is tight. Immediately close the shut-off valve. Listen for an audible
click to signal that the Chek-Lok has opened and is actuated for
liquid withdrawal. The flow can now be controlled by the transfer 7590U or 7591U Chek-Lok®
valve.
4 Check the coupling nut and adapter assembly for leaks using a
F suitable leak detection solution.
If the Chek-Lok fails to open after following this procedure, the
pressure downstream of the shut-off valve should be increased Connecting the 7572FC or
to equalize pressure in the Chek-Lok. It is simple to equalize
pressures using vapor from either the vapor return valve or 7580FC Chek-Lok®
service valve, or from a hose end valve connected to the delivery
truck.
7550P Angle Valve
Instructions to Close Chek-Lok®
1 To re-lock the Chek-Lok, container pressure must be in excess of
35 PSIG. Close shut-off valve and disconnect the hose or piping.
2 Open shut-off valve fully. Liquid discharging to the atmosphere
should cause the excess flow feature of the Chek-Lok to close,
provided tank pressure is 35 PSIG or more.
7572-14A Adapter
If, for any reason, the excess flow valve does not close, the shut-
off valve must be closed immediately and must not be removed
until the system can be evacuated and the unit repaired.
3 After the excess flow valve closes, remove the Adapter and Shut-
Off Valve Assembly. 7572FC or 7580FC Chek-Lok®

4 Clean face of Chek-Lok and install the Cap with a gasket.


IMPORTANT: Only use the proper Chek-Lok Cap. Do not use a In the absence of a 7550P transfer valve, a ¾” A7505A Globe Valve
standard pipe cap. or A7506AP Angle Valve may be used. Follow the above procedures
using the 7572C-15A adapter instead of the 7572C-14A. Use a RegO
7550P without an adapter in an emergency only.

CAUTION: Always wear approved protective gloves when working with the Chek-Lok®. Do not vent LP-Gas near possible source of ignition.

Chek-Lok® Mounting
Chek-Lok® Valves may be either top mounted with a dip tube
or bottom mounted. For bottom mounting, it is preferable to
position the coupling in the head or slightly off of the bottom.
This helps prevent the accumulation of sludge, etc. around the
valve which could affect the proper operation of the excess flow
valve.

F18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Chek-Lok® Excess Flow Valves
7590U and 7591U Series

Application
Chek-Lok® Excess Flow Valves are designed to provide a convenient

10
means of withdrawing liquid from stationary containers prior to REGO
moving the container. The Chek-Lok® permits one transfer shut-off
valve with an adapter to be used interchangeably on a number of
tanks.
YEAR
The 7590U and 7591U Chek-Loks® are also designed for use on WARRANTY
permanent installations provided the excess flow valve is sized
properly for the system and piping. The Chek-lok® contains a weak
section underneath the outlet threads to protect the container from a Cap
pull away incident. Any undue stress could cause this weak section to
C
shear unintentionally if not properly supported and installed. NOTE: In Gasket
some cases, it may be necessary to use an in-line excess flow valve
to protect the downstream piping. This valve is not recommended for
use as a liquid source for pumps.
Chek-Lok B

Features A
• Extra strength connection between body and adapter provides
increased strength.
• Weep hole in cap provides indicator to verify Chek-Lok® is closed
before cap removal. 7590U with Cap
• Heavy duty brass cap requires at least 3½” full turns for removal.
• O-ring seal on adapter provides a gas tight seal before the Materials
adapter opens the equalizing stem. Body........................................................................................ Brass
• Eliminates need for individual transfer valves at each container. Stem........................................................................................ Brass
• UL listed. Spring........................................................................ Stainless Steel
• Temperature range of -40°F to +165°F. (-40°C to +73°C) Seals..................................................................... Synthetic Rubber
• MAWP: 250 PSIG(17 Bar) Valve Poppet........................................................................... Brass
Gasket..................................................................................... Nylon
Ordering Information
A. B. Approximate Closing
F
Body Wrench Hex Approximate Effective C. Flow, Liquid
Chek-Lok® Number Inlet Connection Outlet Connection Flats Length Cap Wrench Hex Flats GPM (Propane)*
7590U ¾” M. NPT 1¾” 17⁄16” 20
15⁄8” UNF 15⁄16”
7591U 1¼” M. NPT 1¾” 17⁄8” 35
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up, and slightly less when installed with outlet down.
Note: Multiply flow rate by .94 to determine liquid butane flow.

Chek-Lok® Liquid Evacuation Adapter for 7590U and 7591U Valves


7590U-20
Application
Designed specifically for use with RegO 7590U and 7591U Chek-
Lok® Excess Flow Valves. Adapter’s operating handle opens and
closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow
through Chek-Lok® valve when installing or removing adapter. Use of
RegO adapter ensures proper connections and opening of the check
mechanism. B

Features
• Built in nylon gasket provides a gas tight seal.

• Adapter can be installed without depressing the equalizing stem of A


the Chek-Lok®.

• Design eliminates the need to slug excess flow feature of Chek-

10
Lok® when removing the adapter.
REGO
• Built in bleeder valve allows controlled discharge of liquid before
removing the adapter.

7590U-20 YEAR
WARRANTY

Ordering Information
Adapter Number Inlet Connection Outlet Connection A Wrench Hex Flats B Approximate Length
7590U-20 1⅝-12 UNF ¾” 1¾” 43⁄16”

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F19
7580F-20 Liquid Evacuation Adapter for older design 7572FC and 7580FC
Chek-Lok® Valves

Application
Designed specifically for use with RegO 7572FC and 7580FC Chek-
Lok® Excess Flow Valves. The adapter’s operating handle opens and
closes the equalizing stem in these older style Check-Lok® valves.
This adapter is designed to eliminate the need for gas to flow from 3 13/32"

the Chek-Lok® when the adapter is installed or removed. A shutoff


valve, such as a full port ball valve must be installed at the outlet of 1 9/32"
the 7580F-20.

Features
• Built in nylon gasket provides a gas tight seal.
• Adapter can be installed without depressing the equalizing stem of 4 15/16"
the Chek-Lok®.
4 3/64"
• Design eliminates the need to slug the excess flow feature of the
Chek-Lok® when removing the adapter. 3 11/64"

• Built in bleeder valve allows for controlled discharge of liquid 7580F-20


before removing the adapter.
Ordering Information

10
Adapter Inlet Outlet Approximate Wrench Hex REGO
15/64"
Number Connection Connection Length Flats
7580F-20 ¾” M.NPT ¾” F. NPT 49⁄32” 13⁄8”
YEAR
IMPORTANT SAFETY WARNING: WARRANTY
For Chek-Lok Valves used on bobtail trucks, be sure operator is properly trained and follows all instructions for opening and
closing the Chek-Lok Valve. Debris might accumulate inside the bobtail truck container and may damage the Chek-Lok
Valve. Routine cleaning of the bobtail truck container and inspection of the Chek-Lok Valve is therefore important.

Union Style Adapters for 7590U and 7591U Valves


F The 7590U-10 adapter must be used to connect to the 7590U and
7591U Chek-Lok. This insures a proper connection to open the check
mechanism. A built-in nylon gasket provides a gas tight seal.

10
REGO

YEAR
WARRANTY
Ordering Information
Adapter Inlet Outlet A. Wrench Hex B. Approximate
Number Connection Connection Flats Length
7590U-10 1⅝” UNF ¾” F. NPT 1¾” 17⁄8” 7590U-10

Adapters for 7572FC and 7580FC Valves


These adapters must be used to connect to the 7572FC and 7580FC
Chek Loks to open the check mechanism properly. A built in nylon
gasket provides a gas tight seal.

10
REGO

YEAR
WARRANTY
7572C-14A
Ordering Information For Transfer
Valves
B.
Approximate
Adapter Inlet Outlet A. Wrench Hex Effective
Number Connection Connection Flats Length
7572C-15A
7572C-14A ¾” F. NPT 1” For Globe and
¾” M. NPT 1⅜”
7572C-15A ¾” M. NPT ¾” Angle Valves

F20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Vapor Equalizing Adapter for 1-1/4” ACME Vapor Equalizing Valves
7573-20

Application
The 7573-20 is designed for use with RegO Multivalve® assemblies
that utilize a vapor equalizing port and 7573 series vapor equalizing
valves. The adapter’s operating handle opens and closes the upper
check stem in the vapor equalizing valve after the ACME connection
is completely made up.

This adapter is designed to eliminate the need for gas flow from the
vapor equalizing valve whenever the adapter is installed or removed.
A shutoff valve, such as a full port ball valve or globe valve must
be installed before the 7573-20 adapter to stop gas flow when
the adapter is not connected.

Features
• Designed to seat against the gasket in the vapor equalizing valve
for a gas tight seal.

• Adapter can be installed without depressing the upper check of


the vapor equalizing valve.

• Designed to eliminate the need to gas discharge when connection


or disconnecting from the vapor equalizing valve.

• Built in bleeder valve allows for controlled discharge of vapor


before removing the adapter from the vapor equalizing valve.

• Built in bleeder valve allows controlled discharge of liquid before


7593-20
removing the adapter.

10
REGO

YEAR
WARRANTY

Ordering Information
Adapter Number Inlet Connection Outlet Connection Approx Length Approximate Width
7593-20 1¼ ” F-ACME ¾” M-NPT 47⁄16” 2⅜”

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F21
Double-Check Filler Valves

General Information
Seal cap made of tough, resilient
RegO Double-Check Filler Valves incorporate a resilient upper check molded plastic. Protects threads
valve, normally designated as a filler valve, and a lower check valve,
and internal working parts. Caps
commonly called a back pressure check valve. Available in a range
are designed to contain normal tank
of sizes to cover virtually all LP-Gas storage containers, these valves
are UL listed and meet NFPA standards, as well as other safety pressures, and must be kept on valves
requirements. at all times.
Long-wearing gasket permits hand-
Flow of liquid into the storage container opens both check valves. tight connection of cap and hose
When flow stops, they both are designed to close automatically to coupling.
permit the operator to disconnect the hose coupling. The automatic
Safety groove is designed to shear
closing action also helps prevent the discharge of container contents
in the event of hose failure. The lower back pressure check affords below the ACME thread, leaving the
extra protection by restricting the discharge if the upper check fails to valve seats closed and unaffected if the
function properly due to accidents or other causes. delivery truck pulls away with the hose
connected.
The double back check construction allows emergency inspection, Seat disc of special synthetic
repair, or replacement of the upper fill assembly without removing
composition is extra thick for longer
product from the container. When the upper filler valve body is
removed, the lower back check valve provides a seal, permitting only
life.
some leakage, allowing a new upper filler valve body to be installed. Valve guide is precision machined to
Spare Gasket Ordering Information ensure positive seal.

ACME Part Number


Exclusive swing-away lower back
check valve for extra fast filling is
1¼” A2797-20R
provided on Models L6579 and 6587.
1¾” A2697-20R Differs from conventional design by
2¼” A3184-8R swiveling to a vertical position when
3¼” A3194-8R opened.

Double-Check Filler Valves for Large DOT and ASME Tanks


L6579 Series and L7579 Series
Application

10
F Designed to provide fast filling of large motor fuel and ASME domestic REGO
tanks. The 6579 Series incorporates a swing-away lower check which
greatly reduces pressure drop across the valve. This lower pressure
drop promotes faster filling rates and greater efficiency resulting in
more profitable operations. YEAR
WARRANTY
Features
• Low emission- 2.14 cubic centimeters at disconnect
(2.14cc versus 6.85cc)
• Double back check provides added system protection.
• Upper filler valve assembly can be easily replaced without
evacuating the container.
• Both checks are spring actuated for quick, precise closure when
flow into the valve stops or reverses.
• 6579 Series swing-away check promotes faster filling for more
profitable operations. E7579 EG167
• Specify RegO Filler Valves on all your original tank purchases to (Float Gauge Extension,
ensure quality and dependable performance. 7579P Can be used with E7579)
• Temperature range of -40°F to +165°F. (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar) A

Materials D
C

Upper Body............................................................................. Brass


Lower Body............................................................................. Brass B
Springs...................................................................... Stainless Steel
Washer and Seat Disc........................................... Synthetic Rubber
Cap......................................................................................... Plastic
L7579
Ordering Information L6579

Part Number A. B. C. D. Propane Liquid Capacity at Various Differential Pressures (GPM)


ACME Hose Tank Connection Wrench Effective Length
Basic With Cap & Lanyard Connection M. NPT Hex Flats (Approx.) 5 PSIG 10 PSIG 25 PSIG 50 PSIG 75 PSIG

L7579 L7579C 1 ⁄ ”
27 32 50 70 111 157 192
7579P* - 21⁄32” 37 52 82 116 142
L6579** L6579C** 1¾” 1¼” 1⅞”
127⁄32” 78 110 174 246 301
L6579
E7579 E7579C 65⁄8”
* Incorporates ¾ F. NPT dip pipe connection (Not a low Emission Connection)
** Swing-away lower back check valve design for higher filling rate. NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

F22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Low Emission Filler Valve with Manual Shutoff Feature
7501L & 7502L

General Information
RegO Manual Double-Back Check filler valves that incorporate
a resilient upper check and a manual shutoff feature. When
filling a container from a delivery truck, this valve will allow flow
into the container through the upper and lower check, when the
manual lever is in the open position. When flow stops both the 0036
upper and lower checks will close; the lever is then turned to the
closed position, the hose-end valve can then be removed from
the filler valve.

Application
Designed for fast filling of larger DOT cylinders and ASME
domestic containers; the 7501L and 7502L feature a manual
shutoff in addition to upper and lower back checks.

Features
• Low emission 2 cc or less at disconnect.

• Meets NFPA 58 and UL requirements.

• Double back check provides added system protection. 7501L


• Checks are spring activated for quick precise closure when
flow stops.

• Manual shutoff valve is designed to provide additional


system protection when disconnecting hose end valve from
filler valve.

• Hose end valve cannot be removed from the 7501L or 7502L


if the lever is in the open position.

• When manual shutoff valve is closed, an integral back check


F
prevents liquid from being trapped between the shutoff and
the upper check.

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

10
REGO

7502L
YEAR
WARRANTY

Ordering Information
Propane Liquid Capacity at Various
Differential Pressures
Part
Number Container Connection ACME Hose Connection 15 PSIG 25 PSIG 50 PSIG
7501L
1¼” M.NPT 1¾” M.ACME 62 GPM 90 GPM 125 GPM
7502L

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F23
Combination Filler and Overfill Protection Device (OPD)
Low Emissions SF7647V Series

Application
This combined filler valve and overfill protection device is designed to 0036
provide fast filling and protection against overfilling of Vertical above
ground small bulk type containers. The SF7647V Series offers good
fill rates and an overfill prevention device that will stop* the flow of
product into the container when the liquid level reaches 80-83% of
its capacity.

Features
• Large flow area for fast filling.

• Resilient seated upper check. TOP OF


CONTAINER
BOSS
• Stable Overfill Protection Device that is integral to the filler valve.

• Overfill Protection Device will stop the flow of liquid when the LIQUID LEVEL
80-83% level is reached. AT OPD CLOSURE
“A”

• Temperature range of -40°F to +165°F. (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Note:

• Must be installed in a vertical position.


• Depending on the application this valve is designed to be used
in conjunction with another device such as a fixed liquid level
gauge or float gauge in low emission transfer systems.

F Materials
Upper body................................................................................ Brass
Lower body................................................................................ Brass
Springs........................................................................Stainless Steel SF7647V
Washer and seat disc..............................................Synthetic Rubber
Cap...........................................................................................Plastic
OPD check................................................................................ Nylon
OPD lever and riser................................................................... Nylon
OPD float................................................................Closed Cell Nitrile

10
REGO

YEAR
WARRANTY

Ordering Information
Propane Liquid Capacity at Various
Differential Pressures GPM
Tank Connection Length
Part Number** ACME Connection M.NPTF Wrench Hex Flats A* 20 PSIG 30 PSIG 50 PSIG
SF7647V08.2 8.2"
SF7647V08.8 8.8"
SF7647V09.3 9.3"
1¾” Male ¾” 1¾” 19 24 50
SF7647V11.0 11.0"
SF7647V11.1 11.1"
SF7647V11.9 11.9"
* Distance from center thread to liquid level at OPD closure.
** Suffix number indicates dip tube length (Fixed liquid level gauge) different lengths available upon request.

F24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Combination Low Emission Filler and Overfill Protection Device (OPD)
SFL7579V Series

Application
The SFL7579V Series filler valve is for use on ASME containers. 0036
This combined filler valve and overfill protection device is designed
to provide fast filling and protection against overfilling of vertical and
horizontal above ground LPG containers. This is typically installed in
the top of horizontal containers.

Features
• Low emission filler valve, will not release more than 2.14cc when
disconnected.

• Large flow area for fast filling.

• Resilient seated upper check.

• Stable Overfill Protection Device that is integral to the filler valve.

• Overfill Protection Device will stop the flow of liquid when the 80%
level is reached.

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Note:
SFL7579V
• Must be installed in a vertical position.
• Depending on the application this valve is designed to be used
in conjunction with another device such as a fixed liquid level
gauge or float gauge in low emission transfer systems. F

Materials
Upper body................................................................................ Brass
Lower body................................................................................ Brass
Springs........................................................................Stainless Steel
Washer and seat disc..............................................Synthetic Rubber
Cap............................................................... Resilient Molded Plastic
OPD check................................................................................ Nitrile
OPD lever and riser................................................................... Nylon
OPD float.................................................... Closed Cell Nitrophenolic A*

10
REGO

YEAR
WARRANTY
Liquid Level at OPD Closure*
Ordering Information
Propane Liquid Capacity at Various
Differential Pressures GPM
Part ACME Hose Tank Connection Length
Number** Connection M.NPTF Wrench Hex Flats A* 1 PSI 25 PSI 50 PSI 75 PSI
SFL7579VE07.5 7.5"
SFL7579VE08.9 8.9"
SFL7579VE10.6 10.6”
SFL7579VE11.1 11.1”
1¾”
SFL7579VE12.3 1¼” 1⅞” 12.3” 23 49 54 66
Male
SFL7579VE13.0 13.0”
SFL7579VE13.8 13.8”
SFL7579VE15.1 15.1"
SFL7579VE17.1 17.1”
* Distance from center thread to liquid level at OPD closure.
** Suffix number indicates dip tube length (Fixed liquid level gauge) different lengths available upon request.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F25
Double Check Low Emission Filler Valves for Forklift and DOT Containers
7647 Series

Application
Designed to provide fast filling of forklift, motor fuel, and recreational
vehicle tanks.

Features
• Resilient seat disc in lower check designed to provide a gas tight Lanyard and Cap
seal without leakage.

• Double back check provides added system protection.

• 7647SA has 30º angle on hose connection. Makes connection


and disconnection easier for certain engine fuel applications.

• Large 1¾” wrench flats on 7647SC allow use of socket wrench for
easy installation.

• Specify RegO Filler Valves on all your original tank purchases to


ensure quality and dependable performance.

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

7647SC

Materials
Upper Body.............................................................................. Brass
Lower Body.............................................................................. Brass
Springs...................................................................... Stainless Steel
Washer and Seat Discs........................... Resilient Synthetic Rubber
Cap......................................................................................... Plastic

7647DC

10
REGO

YEAR
WARRANTY

Ordering Information
Propane Liquid Capacity at Various Differential Pressures (GPM)**
B C D
Part A Tank Connection Wrench Effective Length
Number Hose Connection M. NPT Flats (Approx.) 10 PSIG 20 PSIG 30 PSIG 40 PSIG 50 PSIG
7647DC 1¾” ACME + F. POL 1⅝” 29/16”
¾” 14 20 24 27 50
7647SC* 1¾” ACME 1¾” 111/16”*
* Large 1¾” hex wrench flats.
** Multiply flow rate by .94 to determine liquid butane capacity.

F26 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Double Check Filler Valves for Delivery Truck Tanks and
Large Storage Containers 7579S, 6587EC and 3197C

Application
Designed to provide fast filling of bobtails, transports and large bulk
storage tanks.

The 6587EC incorporates a swing-away lower check which greatly


reduces pressure drop across the valve. This lower pressure drop
promotes faster filling rates and greater efficiency resulting in more
profitable operations.

Features
• Double back check provides added system protection.

• Upper filler valve assembly can be easily replaced without


evacuating the container.

• Both checks are spring actuated for quick, precise closure when
flow into the valve stops or reverses.
7579S
• 6587EC swing-away check promotes up to 65% faster filling rates
for more profitable operations. Faster filling rates add longer pump
life by reducing chances of cavitation.

• Specify RegO Filler Valves on all your original tank purchases to


ensure quality and dependable performance.

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Materials
F
Upper Body............................................................................. Brass
Lower Body (7579S and 6587EC)........................................... Brass
Lower Body (3197C)..................................................... Plated Steel
Springs...................................................................... Stainless Steel 6587EC
Washer and Seat Discs......................................... Synthetic Rubber
Cap (6587EC and 3197C)....................................................... Brass
Cap (7579S)........................................................................... Plastic

10
REGO

YEAR
WARRANTY

3197C

Ordering Information
A. B. D. Propane Liquid Capacity at Various Differential Pressures (GPM)
C.
Part ACME Tank Effective
Wrench 5 10 25 50 75
Number Hose Connection Length
Hex Flats PSIG PSIG PSIG PSIG PSIG
Connection M. NPT (Approx.)
7579S 1¾” 1½” 2” 211⁄16” 44 62 98 139 170
6587EC* 2¼“ 2” 2⅞” 43⁄8” 92 130 206 291 356
3197C 3¼” 3” 4” 6½” 148 210 332 470 575
* Swing-away lower back check valve design for higher filling rates.
NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F27
Single Check Filler Valves for Storage Tanks with Supplementary Back
Check Valves 3174C, 3194C and 6584C

Application
Designed for use with RegO Back Check Valves to provide fast filling
of bulk storage tanks. Also may be used as a spare or replacement
part.

These single check filler valves must never be installed directly into
container couplings. They must be used with the appropriate back
check valve to comply with NFPA Pamphlet #58.

Features
• Specifically for use with RegO Back Check Valves.

• 6584C stem assembly reduces turbulence during filling and


promotes higher filling rates.

• Specify RegO Filler Valves on all your original tank purchases to


ensure quality and dependable performance. 3174C
• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Materials
Upper Body.............................................................................. Brass
Lower Body ............................................................................. Brass
Springs...................................................................... Stainless Steel
Washer and Seat Discs......................................... Synthetic Rubber
Cap (3194C, 6584C)................................................................ Brass
Cap (3174C)........................................................................... Plastic

10
F REGO

YEAR
WARRANTY

3194C, 6584C
Ordering Information
Propane Liquid Capacity at Various
Differential Pressures (GPM)
Outlet For Use With
ACME Hose Connection M. Back Check
Part Number Connection NPT Wrench Hex Flats 5 PSIG 10 PSIG 25 PSIG 50 PSIG Valve:
3174C 1¾” 1¼” 111/16” 23 33 52 74 3176
6584C* 2¼” 2” 2⅜” 156 220 348 492 A3186
3194C 3¼” 3” 3½” 147 208 329 465 A3196
* Stem Assembly designed for higher filling rates.
NOTE: Multiply flow rate by .94 to determine liquid butane capacity.
Seal cap made of tough, resilient molded
plastic. Protects threads and internal working
parts. Caps are designed to contain normal
Vapor Equalizing Valves tank pressures, and must be kept on valves
at all times.
General Information
RegO Vapor Equalizing Valves consist of an upper back check valve Long-wearing gasket permits hand-tight
and lower excess flow valve. In the closed position, the attachment of connection of cap and hose coupling.
a vapor hose coupling with its projecting nozzle, opens the back check Seat disc of special synthetic composition is
valve to permit flow in either direction. The lower excess flow valve is extra thick for longer life.
designed to close automatically when flow out of the container being
filled exceeds the rated capacity. The valve closes automatically when Valve guide is precision machined to ensure
the coupling is removed. Like the double-check filler valves, the vapor positive seal.
equalizing valves utilize a two-piece body construction. The lower Spare Gasket Ordering Information
excess flow valve will permit some leakage when the upper back
ACME Part Number
check valve is removed for emergency repairs or replacement.
1¼” A2797-20R
RegO Vapor Equalizing Valves are designed for use in both ASME and 1¾” A2697-20R
DOT containers.

F28 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Double Check Vapor Equalizing Valves for ASME and DOT Containers
7573 Series and 3183AC

Application
Designed to facilitate loading operations by providing equalization of
pressures in the supply and storage containers. The supplementary
excess flow valve closes when the flow from the container being filled
exceeds a predetermined rate.

The 7573 Series is designed for use in bulk delivery systems and
motor fuel containers. The 3183AC is designed for use in delivery
trucks and other large containers.

Features
• Double check provides added system protection.
• Specify RegO Vapor Equalizing Valves on all your original tank
purchases to ensure quality and dependable performance.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

10
REGO

Materials
Body ........................................................................................ Brass
Spring ........................................................................ Stainless Steel YEAR
Upper Check Seat + ACME ....................................Synthetic Rubber WARRANTY
Body Gasket .......................................................................... Copper 7573 Series
Cap ......................................................................................... Plastic
Ordering Information
Part Number A. B. D. Approx. Closing Flow at
C.
ACME Hose Tank Connection Effective Length 100 PSIG Inlet Pressure
Basic W/ Chain & Cap Wrench Hex Flats
Connection M. NPT (Approx.) (SCFH/Propane)
7573D 7573DC 1¼” ¾” 1⅜” 115⁄32” 4,100
- 3183AC 1¾” 1¼” 2” 229⁄32” 10,000
F
Single Check Vapor Equalizing Valves for ASME and DOT Containers
with Supplementary Excess Flow Valves
Application 3180C
Designed for use with RegO Excess Flow Valves to facilitate loading
operations by providing equalization of pressures in the supply and
storage containers. Also may be used as a spare or replacement part.
These vapor equalizing valves must never be installed directly into
container couplings. They must be used with the appropriate excess
flow valve to comply with NFPA Pamphlet #58.

Features
• Specifically for use with RegO Excess Flow Valves.

• Specify RegO Vapor Equalizing Valves on all your original tank


purchases to ensure quality and dependable performance.

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

10
Materials REGO
Body......................................................................................... Brass
Spring..........................................................................Stainless Steel
Seat Disc.................................................................Synthetic Rubber
YEAR
Seal.........................................................................Synthetic Rubber
Cap...........................................................................................Plastic WARRANTY

Ordering Information 3170


Part Number A. B. C. D. Approximate Closing Flow at
ACME Tank Connection Wrench Effective Length 100 PSIG Inlet Pressure For Use With Excess
Basic With Cap & Chain Connection M.NPT Hex Flats (Approx.) (SCFH/Propane Vapor) Flow Valve:
3170 - 1¼” ¾” 1¼” 17⁄16” 7.600 3272E
- 3180C 1¾” 1¼” 111⁄16” 11⁄2” 10,000 3282A

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F29
Back Pressure Check Valves

General Information
RegO Back Pressure Check Valves are designed to allow flow in one
direction only. The check, normally held in the closed position by a Metal-to-metal seats will allow slight leakage after closure. These
spring, precludes the possibility of flow out of the container. When valves will restrict the escape of container contents in the event of
flow starts into the container, the pressure overcomes the force of accidental breakage of the piping or fittings.
the spring to open the check. When the flow stops or reverses, the
check closes.

Back Pressure Valves for Container or Line Applications


3146 Series, 3176 Series, A3186, A3187S, A3196, and A3276BC
Application
Designed to provide protection of a container opening when desired
flow is always into the vessel. May be used in line applications where
flow must be limited to one direction.

When used with the appropriate single check filler valve, the
combination forms a double check filler valve suitable for use in filling
of bulk storage tanks.

Features
• Generous flow channels for low pressure drop.
• Heavy-duty construction for long service life.
• Soft seat valves have synthetic rubber seat disc for positive seals.
• Temperature range of -40°F to +165°F (-40°C to +73°C) 3146 Series, 3176 Series, A3186, A3196
• MAWP: 250 PSIG(17 Bar)

Materials
Body (3146, 3146S, 3176) ....................................................... Brass
Body (all others) ............................................ Cadmium Plated Steel
F Disc (3146, 3146S, 3176) ......................................................... Brass
Disc (all others) ............................................. Cadmium Plated Steel
Stem (3146, 3146S, 3176) ....................................................... Brass
Stem (A3146, A3196, A3276BC) ............................... Stainless Steel
Stem (A3176, A3186) .................................... Cadmium Plated Steel
Spring ........................................................................ Stainless Steel
Seat Disc (3146S, A3276BC) ................................ Synthetic Rubber
A3276BC
NOTE: The internal (female) pipe thread cannot be used to maintain a leak tight seal on
the A3187S & A3197S. The female internal pipe threads are ONLY FOR STANDPIPE
INSTALLATION INSIDE A CONTAINER.

Pipe Line
(External Connection) Effective Length
A3198S Shown

A B

FLOW
(3"-8 NPTF THD)
Pipe Pipe 8.209
Flow
Caution: Do no t use int er nal c o nnec t io n o n t he Pip e Line. A3198S A3187S
Typical Installation

Container Service Installation

10
REGO

YEAR
WARRANTY

3146, A3146, 3146S, 3147S, A3276BC, 3176, A3176, A3186, A3196

F30 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Back Pressure Valves for Container or Line Applications
3146 Series, 3176 Series, A3186, A3187S, A3196, and A3276BC

A3187S Container Service A3187S Pipe Line Service

Ordering Information
Part Number A B D Propane Liquid Capacity at various differential pressures (GPM)
C
Inlet Outlet Effective
Wrench Hex
Brass Steel Connection Connection Length 5 PSIG 10 PSIG 25 PSIG 50 PSIG
Flats
F. NPT M. NPT (approx.)
3146 A3146
¾” ¾” 1⅜” 115/16” 11 16 25 36
3146S*
3176 A3176 113/32” 28 40 63 89
1¼” 1¼” 2”
A3276BC* 2⅛” 32 45 73 103
A3186 2” 2” 3” 2⅜” 124 175 276 391
A3187S* 2” M & 2” M &
2⅜” 127/32” 60 110 225 350
** 1¼” F 1¼” F
A3196 3” 3” 4” 37/32” 297 420 664 939
A3198S*
3” M & 2” F 3” M & 2” F 3½” 3¼” 210 290 400
**
*Soft seat version.
**The internal (female) pipe thread cannot be used to maintain a leak tight seal on the A3187S & A3197S. The female internal pipe
threads are ONLY FOR STANDPIPE INSTALLATION INSIDE A CONTAINER. F
NOTE: Multiply flow rate by .94 to determine liquid butane capacity and by .90 to determine liquid anhydrous ammonia capacity.

Swing-Away Back Pressure Check Valves for Container or Line Applications


6586D and A6586D
Application
Designed to provide protection of a container opening when
desired flow is always into the vessel. May also be used in the line
applications where flow must be limited to one direction.

When used with the appropriate single check filler valve, the
combination forms a double check filler valve suitable for use in filling
of bulk storage tanks.

The swing-away check offers more efficient flow rates than


conventional designs. It swivels open vertically to reduce pressure
drop across the valve and improves flow rates.

Features 6586D
• Swing-away check design offers faster flow rates.
Materials

10
• Heavy-duty construction for long service life. REGO Body (6586D) .......................................................................... Brass
Body (A6586D) ......................................................................... Steel
• Temperature range of -40°F to +165°F (-40°C to +73°C)
Disc ............................................................................ Stainless Steel
Stem Assembly ...........................................................Stainless Steel
• MAWP: 250 PSIG(17 Bar) YEAR Spring ........................................................................ Stainless Steel
WARRANTY Screw .........................................................................Stainless Steel
Ordering Information
Part Number Propane Liquid Capacity at Various Differential Pressures (GPM)
A. B. C. D.
Inlet Connection Outlet Connection Wrench Effective Length
Brass Steel F. NPT M. NPT Hex Flats (Approx.) 5 PSIG 10 PSIG 25 PSIG 50 PSIG
6586D 2¾”
2” 2” 21⁄32” 190 270 420 600
A6586D 2⅞”
NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO F31
Back Pressure Check Valves for Flanged Installation
A3400L4 and A3400L6

Application
Designed to provide high flow capacity and allow more efficient tank
filling than conventional designs. The unobstructed throat area
reduces flow turbulence through the valve, thereby reducing pressure
drop. Large flow channels and spacious side ports ensure ample
capacity for the most demanding high capacity filling operations.

The valve is designed for installation in internally threaded flanges in


container bottoms.

Features
• Speeds up filling operations in bulk tanks.
• All steel and stainless steel construction ensures long service life.

Materials

10
Body .............................................................. Cadmium Plated Steel
REGO
Stem .......................................................................... Stainless Steel
Spring ........................................................................ Stainless Steel
Disc ................................................................ Cadmium Plated Steel
Guide ..........................................................................Stainless Steel YEAR
Roll Pin ...................................................................... Stainless Steel
WARRANTY
A3400L6
Ordering Information
A. B. D. Propane Liquid Capacity at Various Differential Pressures (GPM)
Flange Connection Wrench Hex C. Threaded End
Part Number M. NPT Flats Overall Length To Port 5 PSIG 10 PSIG 25 PSIG 50 PSIG
A3400L4 2” 5¼” 15⁄16” 223 316 500 707
Slotted
A3400L6 3” 59⁄32” 19⁄16” 424 600 949 1342

F NOTE: For installation in flange tank connections with internal threads, see the “Flanged Installation in Container” section under “Excess Flow Valves.”
Multiply flow rate by .94 to determine liquid butane capacity and by .90 for liquid anhydrous ammonia capacity.

Adhesive Warning Labels 903-500 and 7572-400


The following warning information, Part Number 903-500, is included These adhesive warning labels are intended for application as close
with each shipment of Excess Flow, Check, Filler and Vapor as possible to the Chek-Lok® once the Chek-Lok® is installed.
Equalizing Valves to the first purchaser of the product from the
factory. The basic information contained on the label is intended for the
benefit of the user of the Chek-Lok® and is not intended to be an “all-
This information is intended to be forwarded throughout the product inclusive” product warning.
distribution chain. Additional copies are available from RegO and
Authorized Product Distributors. This label is printed on a heavy duty material with pressure sensitive
adhesive backing. The ultra-violet ink stands up well when exposed
to the environment.
DANGER READ THIS FIRST WARNING
LP-GAS IS EXTREMELY FLAMMABLE AND EXPLOSIVE
AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL OR HEAR
ESCAPING GAS...EVACUATE AREA IMMEDIATELY! CALL YOUR LOCAL FIRE
DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE IN BUILDING OR
ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS OR AIRCRAFT.
Part Number Description
Make sure you are thoroughly trained before you attempt any valve installation, maintenance or repair.
Improper conditions or procedures can cause accidents resulting in property damage and personal injury. 7572-400 Adhesive Warning Label
Become thoroughly familiar with NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspections &
Maintenance” and RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and
“LP-Gas Filler and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve
sections of the L-500 & L-102 Catalogs. Follow their recommendations.
Know and understand NFPA Pamphlet 58 “Liquefied Petroleum Gas Code”, which is the law in many states.
This publication is available from NFPA, Batterymarch Park, Quincy, MA 02269. Following its requirements is
essential in the safe use of LP-Gas. Section 4.4 states: “Persons who transfer liquid LP-Gas, who are employed
to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in proper
handling procedures. Refresher training shall be provided at least every three years and shall be documented.”
Make sure this valve is the proper one for this installation. Avoid misusing LP-Gas equipment.
Apply thread joint compound compatible with LP-Gas on valve external threads only. Make sure compound
never comes into contact with other parts of the valve.
Install valves by applying force to wrenching flats only.
Tighten pipe threads approximately 1 to 1½ turns beyond the hand-tight insertion point using a wrench which
avoids damage to other valve parts.
Check for damage and proper operation after valve installation. Check that the valve is clean and free
of foreign material.
Check container-valve connection with a non-corrosive leak detection solution before filling with LP-Gas.
DANGER WARNING
Purge container before filling with LP-Gas (refer to the RegO LP-Gas Serviceman’s Manual for recommended LP-GAS IS EXTREMELY
procedure). FLAMMABLE AND EXPLOSIVE
Test excess flow check valve for proper operation before placing into service. See NPGA Bulletin 113 for AVOID SERIOUS INJURY AND PROPERTY DAMAGE. IF YOU SEE, SMELL,
recommended procedure.
OR HEAR ESCAPING GAS... EVACUATE AREA IMMEDIATELY! CALL YOUR
Check outlet connection make-up for leaks with a non-corrosive leak detection solution when placing LOCAL FIRE DEPARTMENT! DO NOT ATTEMPT TO REPAIR. DO NOT STORE
into service.
IN BUILDING OR ENCLOSED AREA. DO NOT USE ON HOT AIR BALLOONS
RegO Filler Valves: To prevent damage to the internal checks when it is necessary to utilize an unloading
OR AIRCRAFT.
adapter, use ONLY RegO 3119A, 3120 and 3121 Unloading Adapters with RegO Filler Valves. Carefully
follow the instructions supplied with these unloading adapters.
CAUTION!
Use this CHEK-LOK® connection only for liquid evacuation before moving tank
If container is not being placed into service at the present time, insert plug or cap onto the outlet connection. in accordance with NFPA Pamphlet 58, which is the law in many states. This
In selecting a label for posting at the installation site, consider RegO part number 901-400 or 903-400 along publication is available from NFPA, Batterymarch Park, Quincy, MA 02269.
with your own, NPGA’s and others. Read and follow RegO product instruction number 7572FC-301.
Remember to instruct the owner/user/customer in safety matters concerning LP-Gas and this equipment.
See RegO Safety Warnings “LP-Gas Cylinder Valves”, “LP-Gas Excess Flow Valves”, and “LP-Gas Filler DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL.
and Hose End Filling Valves” found in the cylinder valve, excess flow valve, and filler valve sections of the DO NOT FILL THIS CONTAINER UNLESS THIS LABEL IS READABLE.
L-500 & L-102 Catalogs.
ADDITIONAL SAFETY INFORMATION IS AVAILABLE FROM
RegO requests that this information be forwarded to your customers. Additional copies are available from Printed in U.S.A. 05-0114-0386
RegO and your authorized RegO Distributor. Part Number 7572-400
Printed in USA 09A-0910-0686 Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com
Part number 903-500
Elon, N.C. 27244 U.S.A. Phone (336) 449-7707 Fax (336) 449-6594 www.regoproducts.com

903-500 7572-400
F32 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section G
Internal Valves and Accessories G G

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
G warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

G2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. G
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G3
Warnings

Purpose
In its continuing quest for safety, RegO publishes a series of bulletins explaining the hazards associated with
the use, misuse, and aging of LP-Gas valves and regulators. It is hoped that these factual bulletins will make
clear to LP-Gas dealer managers and service personnel, that the utmost care and attention must be used in
the installation, inspection, and maintenance of these products, or problems could occur which would result in
injuries and property damage.

The National Fire Protection Association NFPA 58 Liquefied Petroleum Gas Code - 2020 Edition states in
Section 4.4 Qualification of Personnel; ”Persons whose duties fall within the scope of this code shall be
provided with training that is consistent with the scope of their job activities and that includes proper handling
and emergency response procedures... Refresher training shall be provided at least every 3 years, initial and
subsequent training shall be documented”. These “RegO Safety Warnings” may be useful in training new
employees and reminding older employees of hazards that can occur. It is recommended that all employees
complete the Propane Education Research Council’s Certified Employee Training Program.’

Nature of Warnings
It is recognized that warnings should be as brief as possible, but the The exact procedure used may vary with the installation, advisability
factors involved in internal valve and excess flow valve failures to of gas discharge and availability of equipment.
perform are not simple. They need to be fully understood. If there is a
simple warning, it would be: In general, most testing makes use of the fact that the excess
flow valves are “surge sensitive’’ and will close quicker under a
Make sure that the internal valve’s excess flow feature really sudden flow surge than under steady flow. A sufficient surge can
closes when the flow exceeds rated closing flow, and that the often be created by using a quick open/close valve to control
valve will shut-off. sudden, momentary flow into a tank or piping section containing
very low pressure. An audible click from the excess flow valve (and
This bulletin is not intended to be an exhaustive treatment of internal corresponding stoppage of flow) indicates its closure.
valves, and certainly does not cover all safety practices that should
be followed in installation, operation and maintenance of LP-Gas
systems, which include internal valves. A test involving venting gas to the atmosphere is hazardous and
may be impractical, or illegal.
Internal valves must be closed on Cargo Vehicles when traveling
G on public roads and highways. The valve should only be open Any test of any excess flow valve will not prove that the valve will
when pumping. Per MC 330 or 331, internal valves must also be close in an emergency situation, due to reasons cited before. This
equipped with remote closure system when used on transports test will only check the valves condition, and the flow rate sizing for
or bobtails. those test conditions.
There are two types of internal valves being used on storage
3. Tight Shut-Off — A test should be made to ensure the internal valve
tanks, transports and bobtails — spring loaded internal valves and
will give a gas tight seal when the valve is in the closed position. This
differential pressure internal valves. They both provide positive shut-
will require removal of all product downstream from the internal valve,
off when product is not being withdrawn and may include excess flow
to ensure the valve will give 100% seal when in the closed position.
protection for the system during transfer operations.
If the internal valve does not give 100% seal the valve should be
repaired immediately.
Spring Loaded Internal Valves

Spring loaded internal valves are manually opened by levers, by


means of fuse linked cable mechanisms or pneumatic or hydraulic
actuators. They incorporate an excess flow feature that will close the
valve when the flow through the valve exceeds its rate of flow. These
valves should never be locked open by means of wires, chains, pegs
or other devices.

Testing

Testing should be completed on a periodic basis.

1. To check operation of a spring loaded valve, activate the remote


control to close the valve while unit is pumping. If the meter indicator
flow continues, the valve should be repaired immediately.

2. Testing excess flow feature.


The National Propane Gas Association Safety Bulletin #113-78
states: “In order to test an excess flow valve in a piping system, the
flow through the valve must be made to exceed the valve’s closing
rating.’’

This testing should only be attempted by trained personnel


familiar with the process. If no one at the facility has experience in
proper testing, outside expert help should be obtained.

G4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pressure Differential Internal Valves (Flomatics®)

Pressure differential valves (Flomatics®) open by pump pressure and


close when the pump stops.These valves must never be locked open
by means of wires, chains, pegs or other devices.

Testing

Testing should be completed on a periodic basis.

1. To check operation of a differential pressure internal valve activate


the remote control shut-off valve while the unit is pumping. If the
meter indicates that flow continues the valve should be repaired
immediately.

2. Since the differential pressure internal valve requires at least 18


psi to open and 8 psi over container pressure to keep open, a test
may be performed to check for closure. With the PTO disengaged,
connect delivery hose to a container with very low pressure. Then
with hose end valve open, engage PTO. The internal valve should
remain closed, no flow should be detected through the meter. If
flow continues through the meter the valve should be repaired
immediately.

3. Tight Shut-Off — A test should be made to ensure the internal valve


will give a gas tight seal when the valve is in the closed position. First
ensure the pump prime valve is closed by turning clockwise until it
seats. Then with the valve closed (PTO disengaged) the product
downstream from the internal valve will have to be safely removed.
If the internal valve does not give 100% seal, the valve should be
repaired immediately.

General Warning
All RegO Products are mechanical devices that will eventually
become inoperative due to wear, contaminants, corrosion and aging G
of components made of materials such as metal and rubber.

The environment and conditions of use will determine the safe service
life of these products. Periodic testing at least once a year when tank
pressures are low and maintenance, as required, are essential.

Because RegO products have a long and proven record of quality


and service, LP-Gas dealers may forget the hazards that can occur
because an excess flow valve is used beyond its safe service life. Life
of an excess flow valve is determined by the environment in which
it “lives’’. The LP-Gas dealer knows better than anyone what this
environment is.

NOTE: There is a developing trend in state legislation and


in proposed national legislation to make the owners of products
responsible for replacing products before they reach the end of their
safe useful life. LP-Gas dealers should be aware of legislation which
could effect them.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G5
Manual Internal Valves

A3200 Series
These valves must remain in the closed position except during
General Information product transfer. A line break downstream of the pump may fail to
actuate the excess flow valve as the pump may limit flow. If break
Manual Internal Valves are designed for a variety of uses in LP-Gas occurs in the system, or the excess flow closes, immediately shut
and anhydrous ammonia service. In addition, accessories allow most down the system.
of them to be actuated manually, by cable or with air.
Inspection and maintenance on a periodic basis is essential.
Installation, usage and maintenance of this product must be in Installation and maintenance must be performed only by qualified
compliance with all RegO instructions, as well as requirements and personnel.
provisions of NFPA # 58, DOT, ANSI, and all applicable federal, state, Be sure all instructions are read and understood before installation
provincial, and local standards, codes, regulations and laws. and operation of these valves.

How The Valves Work 5. Always keep valve closed except during product transfer.
Refer to the drawings. View “A’’ shows the valve held closed without 6. Completely open all valves during pumping. Partially closed or
leakage by tank pressure and the valve’s closing spring. Actuation throttle type valves may prevent excess flow valve from closing when
of the operating handle alone does not open the valve, it only allows required, even in a properly designed piping system.
pressure to equalize between the inlet and outlet of the valve by rapid
bleeding of the product downstream. This equalized pressure then 7. All personnel must be aware of remote closure locations and
allows the valve to open via the internal spring. their operation in case of emergency. They must also be aware of
the equalizing opening through which bleeding can occur after the
The valve opens by moving the handle to mid-point, see view “B’’. excess flow valve closes. If this bleed is not stopped by closing a
This position allows the actuator to put the equalizing portion of downstream valve, a hazard may occur.
the valve stem in the pilot opening, allowing more product to bleed
downstream than if the handle was fully open. 8. Never, under any circumstances, permanently wire open the
operating handle of the internal valve.
In a few seconds, the tank and downstream pressure will be nearly
equal. The excess flow spring will push the main poppet to the open
position, see view “C’’, the handle should then be moved to the fully
Cable Control System
open position.
The cable control system employed must meet the requirements
If at first, the handle is quickly moved to the fully opened position, the and be in accordance with the provisions of NFPA #58, DOT,
pilot valve allows a small amount of bleed downstream, but much less ANSI, and all applicable federal, state, provincial and local codes.
G than during rapid bleed (view “B’’). This results in a longer pressure
equalizing time before the main valve can open.
Troubleshooting
NOTE: The main poppet will not open until outlet pressure
approximates tank pressure! 1. Internal Valve Will Not Open. Causes may be excess leakage
downstream, pump engaged too quickly, excessive wear of valve, or
Once the main poppet is open, flow greater than the excess flow ice freezing of poppet.
rating, or a sufficient surge in flow, forces the main poppet closed When there is excessive volume downstream, a greater amount of
against the excess flow spring, as seen in view “D’’. The pilot valve in time is required to equalize tank and downstream pressure.
this position is open and allows a small amount of bleed downstream, To determine if the pilot seat is opening, install a pressure gauge
but much less than during rapid bleed (view “B’’). downstream of valve outlet, open any hand valves between valve and
pressure gauge, and open valve. Pilot seat is not opening if pressure
When the operating handle is moved to the closed position, the valve does not build up to tank pressure. Perform this test with pump off. A
closes and a leak-tight seal is re-established as seen in view “A”. broken internal part may cause pilot seat not to open.
If operating handle rotates past the full open position, there is internal
NOTE: To provide excess flow protection, the flow rating of the pump, malfunctioning, and the valve must be disassembled and repaired.
piping, valves, fittings, and hose on the inlet and outlet sides of the
2. Premature Valve Closure.
valve must be greater than the flow rating of the valve. Any restrictions
that reduce the flow to less than the excess flow valve rating will result First, check to see that operating lever is properly connected and fully
in the excess flow valve not operating when required. opens valve. Premature closure may also be a result of engaging
pump too quickly, sudden line surges, an underrated excess flow
Valve Operation and Precautions spring or an obstructed inlet port.
3. Valve Will Not Close.
1. Valve must be opened before starting pump, and before opening Usually a result of faulty or sticking actuator. First, check the actuator
valve on pump outlet. to see that it works freely by disconnecting it from valve handle and
cycling it several times. Also, operate valve handle manually. If it
2. Leave pumping system “wet’’ to avoid drying of seals and to reduce sticks in the open position, replace the packing and bushings. This
time involved in opening valve. Drain piping only when required by should free the operating mechanism providing the valve has no
codes or safe operating practices. internal damage.
3. When piping is dry or at lower pressure than the tank, open valve
4. Low Flow Capacity
half-way for a few seconds to allow line pressure to equalize before
Downstream piping may be too small and/or long, screen or strainer
fully opening the valve handle. The main poppet may not open
immediately if the handle is placed in the open position too quickly. may be plugged, possible restriction downstream, or a bypass valve
stuck in the open position are causes of low flow. Also, the bypass
4. Flow surges may close the built-in excess flow valve and should valve may be set too low and prematurely opening. Check for high
be avoided. If the valve slams shut, immediately stop the pump, close differential pressure across the bypass valve. If bypass valve is open,
the nearest downstream valve, and move handle to midpoint position the differential across the valve should not exceed 5 to 6 psig.
to equalize pressure until valve reopens with a click, then restart
pump and open downstream valve slowly.

G6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Maintenance

Potential problems may be eliminated with preventive internal valve 3. Inspect, clean and oil all operating controls. Check controls to see
maintenance. Perform the following steps once a month: that they open fully, but do not overtravel the valve operating lever.
See that they work freely to close the valve. Worn parts should be
1. Check to see that the operating lever moves freely and smoothly. replaced.
There should be no leakage around the lower stem or seal housing.
Leakage requires replacement of the seal housing packing. A sticking 4. Remove valve if the tank is to be steam cleaned. Heat may
lever indicates trapped foreign material or mechanism wear. damage the valve’s seals.

2. Check both seat discs for tight closure. Close valve and exhaust 5. Valve is not designed for water service. After tank is hydrostatically
downstream pressure. Be sure piping is warmed to an ambient tested, immediately remove all water and allow tank to thoroughly dry
temperature. Close the first downstream valve and note pressure out before installing valve.
buildup between the closed valves with a pressure gauge. If leakage
occurs, replace both seat discs.

A3209D Series, 1¼” Straight


A3209DT Series, 1¼” Tee Body
A3211D Series 1½ Straight
A3212R Series, 2” Straight
A3212RT Series 2” Tee Body
A3213D Series, 3” Straight
A3213DT Series 3” Tee Body

A3219FA Series, 4” Flanged

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G7
RegO Internal Valves - Know the Facts.
A better built valve, means lower cost of ownership.
Highest Flow Rate
RegO internal valves have the highest flow rate at the lowest
Better Support Saves You Money pressure drop. Allowing for a higher downstream pressure and
• 10-year warranty is twice the industry average giving greater flow rate.
you peace of mind.
A3217A & FA
A3217A Series
& FA Series
• Largest distributor network with locations near you 600 600
and experts to support you. 500 500

400 400
Reliable Product Saves You Money

GPM -Propane
GPM -Propane
300 300

• Superior design with features that provide 200 200

functionality you can count on. 100 100

0 0
• Manufacturing excellence in our factories means every 0.250.25 0.5 0.5 0.750.75 1 1 1.5 1.5 1.6 1.6 1.7 1.7 2 2 2.3 2.3 2.5 2.5 3 3 3.5 3.5

product has consistent quality.


DropDrop
Through Valve
Through PSI PSI
Valve

• 100% testing of all products for proper functional use,


for example, leakage, lockup and set pressure. All
products are tested at multiple steps in the process
from incoming component quality to final assembly.
• Meet or exceed UL 125 and NFPA 58 standards.

Ease of Installation and Service


G Saves You Money & Time
Electric Actuation
• Installations are quick and easy, available in flanged,
double flanged and threaded, the valves may be
operated manually by cable, pneumatically electrically
or with a rotary actuator.
• Sizes ½” - 4“
• Internal valves are serviceable easily by service
personnel.
• Quality products mean less service calls from your
customers.
Rotary Actuation

Machined Excellence
Precision machined stem &
housing to allow for accurate
guidance of the stem and seat Pneumatic Actuation
assembly.

Manual Actuation

10
REGO REGO

100%
TESTED YEAR
WARRANTY

G8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Excess Flow Feature How to Size Internal Valves
The excess flow feature will Internal valves are rated in closing flow not rated flow capacity.
allow for protection to help The closing flow can range from -20% to +10% from what is marked
control discharge of product on the body or in the catalog. To provide proven excess flow
in the event of of complete protection, the flow rating of the pump, piping, valves, fittings and
breakage of pipelines or hose hose on the inlet and outlet sides of the valve must be greater
ruptures. than the flow rating of the valve. Any restrictions that reduce the
flow to less than the excess flow valve rating will result in the
excess flow valve not operating when required.

To select the correct closing flow


for the proper application
ries
7A Se s
A321 Valve Manual
ernal

Easy to Service
3" Int and Ope
ration
tion
Installa

• Determine the maximum GPM or CFH flow the


and
sports
ks, tran
very truc design
tail deli feature
d on bob cial
be use air. Spe
e can or with
The valv cable

RegO internal valves are easy


uall y, by 1 tank
d man Figure age by

system will require


operate g
Wo rks - Seeed without leak
of the
operatinto
e Valve clos n sure
Th e held Actuatio ws pres ding
How shows the valv spring. allo d blee ws
closing valve, it only e by rapi allo
“A” valve’s n the et of the valv sure then
and the s not ope

to service and come with


View pres
outl alized
pressurealone doe t and
w “B”
.
the inle . This equ ng. ee vie
handle e between eam spri oint, s portion of
equaliz downstrthe internal mid-p
product dle to ing
equaliz uct to blee
d
of the e to open
via
n g t h e han the prod
vi put e
the valv by mo actuator to wing mor
pens rly

detailed instruction sheets to


alve o allows the opening, allo open. be nea
The v ition pilo t was fully sure will
This pose stem in the the handle eam pres ed to
the valv eam than
if
and downstr be mov
tank then
downstr s, the should

• Add 50% to this value and use it to select the


second handle
In a few “C”, the but
eam,

get the job done right.


view
, see ition.
position downstr lts in a
open opened
pos bleed resu
fully amo unt of “B”. This can open.
the small d ,vie
w valve
ws a main
e allo ng rapid blee re the ap-
t valv duri time befo
sure
the pilo et pres
less than alizing until outl

appropriate closing flow


much pressure equ open
longer pet will not
n pop
The mai sure!
NOTE: tes tank pres
of thiss proxima

G
nance tion allows
mainteO® instruc A ope n and
and , NFP is
usage with all RegNFPA #54 ial and position much less

10
tion, e in this REGO
Installacompliance ons of provinc pilot valv
, but
NG: provisi l, state, nstream
in
WARNI t must be ments andble federa s. ing “D”. The of bleed dow
and law except durmay view unt
producl as requireall applica ulations ition ll amo ed YEAR
pump a sma the clos
as wel T, ANSI, codes, reg closed pos m of the ,view
“B”. ed to seal is re- WARR
ANTY
DO bleed is mov
#58, ds, in the nstrea than t
standar remain break dow rapid handle a leak-tigh
local must during rating and
valve sfer. A line the ope e closes
This t tran
.
essent be
ial. When , the valv n in view “A”.
system is
produc the is ition see

Example: 3” Single flanged internal valve needed


st
down iodic
bas ce mu pos hed as
shut a per ntenan establis
imm ediately nance on and mai al-
nte air inst
closes, mai ly, rep before must
on and ssemb erstood tions
Inspectition, disa and und se instruc
Inst alla read ce. The t. e
s are produc ted or hav -
ruction maintenan r of the
e all inst and use not be
pain
Be sur operation to the end must to a
g fuses osed
lation, sed alon rmal n exp
be pas s or the on whe
l link activati onia
Therma from e, amm NH3
device propan th!
rmal °F. liquid ry or dea ts that
the the 250 ion of ren and
vent ature of inju
inhalat serious rs in air cur ple
temper tact or se doo to peo open
TIO N: Conors can cauased out exposure from any
t
CAU ir vap st be rele preven ugh
and the Gas mu ersion to far eno porate
kept e or eva
and LP- re disp st be

330 GPM 150% 495 GPM


Gas mu dispers
will insu ck. LP- may not
livesto n air and d
vier tha still air. designe .
is hea d in es are ammonia

X =
LP-Gas if release rnal Valv ydrous
rapidly ged Inte anh
ord 3" Flan ne and

System Flow Sizing Factor Selected Closing Flow


Forew 17A Series propane, buta
A32 with
The for use
primarily

An A3217AR510 would be the proper valve for LPG service. When


ordering valves selecting the proper coupling and LPG or NH3
service will allow for the proper closing flow as seen listed below.

Reliable Service
Sturdy linkage design to
allow for optimal movement
between the stem and lever
arm assembly. Part Closing Flow
Number GPM, LPM
Right Position Left Position LP-Gas NH3
Operating Lever Operating Lever GPM GPM

Single Flange
A3217AR160 A3217AL160 160 145
A3217AR210 A3217AL210 210 190
A3217AR260 A3217AL260 260 236
A3217AR410 A3217AL410 410 372
A3217AR510 A3217AL510 510 459
Double Flange
A3217DAR160 A3217DAL160 160 145
A3217DAR210 A3217DAL210 210 190
A3217DAR260 A3217DAL260 260 236
A3217DAR410 A3217DAL410 410 372
A3217DAR510 A3217DAL510 510 459

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G9
Upgrade your system with Electric Actuators
Easy Installation | Dual Fail-Safe Protection | Maintenance-Free
Electric Actuators are a simple, safe and reliable solution General Specifications
with accurate and smooth motion control. There is Torque Range Speed Range
Model (in-lbs) (time to open)
no need for a compressed air source and no concern RDM 44 .. 95 2 sec .. 10 sec
of moisture freezing shutting a system down. Remote
• Enclosure: NEMA 6 / IP67 IP67 / 40°C (104°F)
emergency-shut-down locations can be easily installed and
• Enclosure: Class 1, Div 1 Groups D, C, D /T6
easily maintained. The electric actuators come installed • Temperature Range: -40°C/F .. 70°C (185°F) Internal
on the valve and are tested for proper operation at the heater standard
factory. All electric actuators are rated CSA UL Class 1 Div 1 • Finish: Anodized white, Stainless

Explosion proof enclosures. • Stall Protection: By current sense and motion detection
• Feedback: Limit switches
• Life Expectance: 250,000 cycles or equivalent under
Electric actuators are available to retrofit existing RegO
specified conditions
valves and are easy to install. Positional indication and • Motor: BLDC brushless DC motor
operation, can be remoted to a truck cab or control panel • Voltages: 12/24 VDC
G (or PLC) to indicate valve position. Manual override handle • Positioning precision: +/- 3 deg
• Range Setting: Set according to valve
also indicates position and can be used for Lock-Out. An
• Speed setting: Set according to valve
internal heater is installed to ensure reliability. A thermal
• End of travel detection: By current sense and motion
fuse is incorporated to ensure no over temp. detection
• Power setting: Set according to valve
Safety Features • Motor control: Internal micro controller
• Mechanical shock: 1 m drop test no damage to function
Random SAE J1211, Chassis, Exterior
• Mechanical vibration: Random SAE J1211, Chassis,
Exterior
Fusible Link
UL rated
mechanically fails at
100°C (212°F) allowing
• Housing: All housing parts anodized aluminum
internal valve’s spring
to shut off the flow. • Bearings: Oiled for life porous bronze bearings
• External Fasteners: Stainless Steel
• Manual Override: Mounted Directly on the valve stem
• Control: 12/24 VDC TTL
• Limit Switches: Switches are triggered at fully closed,
Electronic Thermal Cut-Off and fully open position. (independent I/O)
Internal component cuts power line at 89°C (208°F).
Actuator closes when power is lost.

G10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pneumatic Rotary Actuators
A3200OA Series

Application
These actuators provide the opening and closing of valves in
hard to reach or remote areas. Useful on bobtail delivery trucks,
transport trailers, and bulk plants, their remote control can safely
be piped to almost any location.

Features & Benefits


• For use with propane vapor, nitrogen or compressed air

• Compact size with same power and torque for easier placement.

• Low-friction construction with self-lubricated strips prevents the


actuator from sticking even after long periods of inactivity

• Double-acting movement powerful in both opening and closing


for true automated control.
A3217LOA
• Wear items, including pins, slots and bushings made of hardened
steel for the utmost durability and longevity.

• Scotch yoke design turns linear motion of piston into rotary


motion for valve actuation and eliminates rack and pinion, teeth
and gears that are susceptible to stripping, providing a lighter
weight, smaller product with longer life.

• Rolled cylinder provides a super smooth surface finish for less 10.11
wear and longer life.

• Expected service life 1,500,000+ cycles


8.52

Materials G
Body....................................................................................Aluminum
Springs.................................................................................Stainless
Stem Seals................................................................................ Nitrile

3.29

10
REGO
1.28

YEAR 2.01
WARRANTY 3.13

Ordering Information
Part Number For use with Recommended Supply Pressure Actuator Pneumatic Inlet Connection Outlet Connection

A3209OA A3209D
A3211D 25-120 psi (1.8-8.4 bar)
A3212OA A3212R
A3213OA A3213D 35-120 psi (2.4-8.4 bar) ¼” NPT Filtered vent
A3217LOA A3217AL
A3217DAL
50-120 psi (3.4-8.4 bar)
A3217ROA A3217AR
A3217DAR

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G11
1¼” Threaded Internal Valve for Small Capacity Pumping Systems and
Bobtail Vapor Equalization A3209D & A3209DT Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia as a
main valve on small capacity pumping systems, NH3 nurse tanks and
in-line installations. It may also be installed in the vapor equalizing
opening on bobtail delivery trucks. Installation is quick and easy, and
it fits in both full and half couplings, as well as, in-line applications.
The valve may be actuated manually by hand or cable.

Features
• Valve is compact, with one piece body construction.
• Spring loaded V-packing with heavy duty wiper ring on operating
shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation. A3209DT
• Simple operating lever allows for easy connection of cable controls.
• Built in excess flow valve
• Return spring forces the valve to the closed position when the
lever is released. Top View 2¾”
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position allows for quick pressure equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection.
A3209D
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

A3209EA

10
G REGO
A3209PAF
Materials
Body............................................................................... Ductile Iron
Operating Lever................................ Cadmium Plated Carbon Steel
Stem.......................................................................... Stainless Steel YEAR
Springs...................................................................... Stainless Steel WARRANTY
Seat Disc................................................ Resilient Synthetic Rubber A3209TL
Shaft Bearing........................................................................... Nylon

Seat disc fully retained and


field replaceable

A3209PA A3209OA
A3209D Series
90

80 Half Coupling

70

60

50
GPM-Propane

40
Full Coupling
30

20

Cam attached with Allen 10

head fastener which is 0


0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4 5 6 7 8
accessed from the ¼” pipe Drop Through Valve PSI
Ordering Information plug on side of the body

Inlet Outlet Closing Flow LP-Gas Vapor Capacity** (SCFH/Propane) Accessories


Part Number Connection Connection Thermal Pneumatic Rotary Electric
M. NPT F. NPT LP-Gas NH3 25 PSIG 100 PSIG
Latch Actuators Actuator Actuators
A3209D050 1¼” 1¼” 50 45 13,300 22,900
A3209D080 1¼” 1¼” 80 72 15,700 26,700 A3209PA
A3209TL A3209OA A3209EA
A3209DT050* 1¼” 1¼” 50 45 13,300 22,900 A3209PAF

A3209DT080* 1¼” 1¼” 80 72 15,700 26,700


* T-Body Design

G12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
1¼” Threaded Internal Valve with Electric Actuator for Small Capacity
Pumping Systems and Bobtail Vapor Equalization EA3209E Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia as a
main valve on small capacity pumping systems, NH3 nurse tanks and
in-line installations. It may also be installed in the vapor equalizing
opening on bobtail delivery trucks. Installation is quick and easy, and
it fits in both full and half couplings, as well as, in-line applications.

Features
• One piece body construction.
• Spring loaded V-packing with heavy duty wiper ring on operating
shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Excess flow valve feature
• Return spring forces the valve lever to the closed position when
the power is de-energized.
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position (rapid bleed) allows for quick pressure
equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve
4 downstream (no hydrostatic relief valve
3 required; swing 2 1
check will open and allow backflow at minimal differential
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection. EA3209D Series
• Provides a convenient means of electrically opening and closing
the valve from a remote location.
D • CSA/UL rated Explosion Proof Enclosure on the actuator. D
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC (2.38) (1.88)
• Internal Valve is UL Listed and TPED Certified
• Electric Actuator is ATEX Certified
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) 4 3 2 1

G
D D

(2.38) (1.88)
(1¼-11½ NPTF THD)
C Materials C
Body............................................................................... Ductile Iron
Operating Lever................................ Cadmium Plated Carbon Steel
Stem.......................................................................... Stainless Steel (7.50)
Springs...................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber (1¼-11½ NPTF THD)
Shaft Bearing...........................................................................
C
Nylon C

10
(7.50)
REGO "A"

B YEAR B
WARRANTY "A"
(1¾-11½ NPTF THD)
(7.69)
B 36° B
(9.30)
(1¾-11½ NPTF THD)
(7.69)
36°
Ordering Information (9.30)

LP-Gas Vapor Capacity** (SCFH/


Inlet Connection Outlet Connection Closing Flow
Part Number Voltages Propane)
M. NPT F. NPT
LP-Gas NH3 25 PSIG 100 PSIG
A A
EA3209D050 1¼” 1¼” 50 45 13,300 22,900
A A
EA3209D080 1¼” 1¼” 80 72 15,700 26,700
12/24 VDC
EA3209DT050* 1¼” 1¼” 50 45 13,300 22,900
EA3209DT080*
4 1¼” 1¼” 3 80 2 72 15,700 126,700
4 3 2 1
* T-Body Design
**Data for full flow in half coupling.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G13
Straight Through 1½” Internal Valve
A3211D Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia as a
main valve on pumping systems, and in-line installations. Installation
is quick and easy and it fits in both full and half couplings, as well as,
in-line applications. The valve may be opened manually by hand or
pneumatic actuator.

Features
• Valve is compact, with one piece body construction.
• Spring loaded V-packing with heavy duty wiper ring on operating
shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Simple operating lever allows for easy connection of cable controls.
• Built in excess flow valve
• Return spring forces the valve to the closed position when the
lever is released.
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position allows for quick pressure equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential A3211D
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection.
• Temperature range of -40°F to +165°F (-40°C to +73°C) A3211D Series
120
• MAWP: 400 PSIG(27 Bar)
100
Half Coupling
80
GPM - Propane

60
Materials
G Body............................................................................... Ductile Iron
40 Full Coupling

Operating Lever................................ Cadmium Plated Carbon Steel 20


Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel 0
0.2 0.3 0.9 1 1.5 2 2.2 3 2.5 3 3.7 4.2 5.5 6.2 6.9 7.8 8.4 9 9.5 9.8
Shaft Bearing........................................................................... Nylon Drop Through Valve PSI
Seat Disc............................................................... Synthetic Rubber

(4.51)

(2.91))

A3209TL

10
REGO (6.88)
OPEN A3209EA
(6.56) A3209PAF
CLOSED

YEAR
WARRANTY

(R3.00)
(2.07)

A3209PA
A3209OA

Ordering Information
LP-Gas Vapor Capacity
Closing Flow GPM (SCFH/Propane) Accessories
Half Coupling Full Coupling
Part Inlet Outlet Thermal Pneumatic Rotary Electric
Number M.NPT F.NPT LP-Gas NH3 LP-Gas NH3 25 PSIG Inlet 100 PSIG Inlet Latch Actuator Actuator Actuator
A3211D080 1½” 1½” 80 72 63 67 15,700 26,700
A3209TL A3209PAF A3209OA A3209EA
A3211D110 1½” 1½” 110 99 84 76 N/A N/A

G14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Straight Through 1½” Internal Valve with Electric Actuator
EA3211D Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia as a
main valve on pumping systems, and in-line installations. Installation
is quick and easy and it fits in both full and half couplings, as well as,
in-line applications.

Features
• One piece body construction.
• Spring loaded V-packing with heavy duty wiper ring on operating
shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Excess flow valve feature
• Return spring forces the valve lever to the closed position when
the power is de-energized.
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position (rapid bleed) allows for quick pressure
equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection.
• Provides a convenient means of electrically opening and closing
the valve from a remote location.
• CSA/UL rated Explosion Proof Enclosure on the actuator.
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC
• Internal Valve is UL Listed and TPED Certified
• Electric Actuator is ATEX Certified EA3211D Series
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) G

Materials
Body............................................................................... Ductile Iron
Operating Lever................................ Cadmium Plated Carbon Steel
Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel
Shaft Bearing........................................................................... Nylon
Seat Disc............................................................... Synthetic Rubber

A3211D Series
120

100
Half Coupling
80
GPM - Propane

60

10
40 Full Coupling
REGO
20

0
YEAR 0.2 0.3 0.9 1 1.5 2 2.2 3 2.5 3 3.7 4.2 5.5 6.2 6.9 7.8 8.4 9 9.5 9.8

WARRANTY Drop Through Valve PSI

Ordering Information
LP-Gas Vapor Capacity (SCFH/
Closing Flow GPM Propane)
Half Coupling Full Coupling
Part
Number Inlet M.NPT Outlet F.NPT Voltages LP-Gas NH3 LP-Gas NH3 25 PSIG Inlet 100 PSIG Inlet
EA3211D080 1½” 1½” 80 72 63 67 15,700 26,700
12/24 VDC
EA3211D110 1½” 1½” 110 99 84 76 N/A N/A

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G15
3” Flanged Internal Valves for Bobtail Delivery Trucks, Transports and
Large Stationary Storage Containers A3217A & A3217DA

Application
Designed primarily for LP-Gas and anhydrous ammonia filling and/
or withdrawal on MC331 bobtail delivery trucks, transports and
stationary storage tanks with flanged pumps or piping. Installation
is quick and easy, and the valve may be operated manually by cable

10
or pneumatically. Lever available on right or left side to allow for
REGO
installation without the use of an extra pulley.

Features
Provides More Efficient Operation YEAR
WARRANTY
• Flow passages designed to allow substantially higher without
cavitation or loss of efficiency--saving time and money.
• Simple operating lever facilitates easy adaptation of all cable
controls.
• Lever available on right or left side to allow for installation without
the use of an extra pulley.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Less Frequent-Easier Maintenance

• Stainless steel screws resist rusting and are easily removed


during valve disassembly. A3217AR
• Heavy duty rod wiper helps minimize dirt and foreign material from
entering operating shaft and hampering operation.

G Durable Construction

• All ferrous materials with a temperature range of -40° F. to +165° F.


and a pressure rating of 400 psi.
• Sturdy retaining ring secures operating cam to provide for more
durable, slack-free operation.
• Built-in excess flow valve.
• Specify RegO Internal Valves on your next new tank or when your
truck is rebuilt.

Ordering Information
Closing Flow
GPM Accessories
Pneumatic Actuator
Operating
Part Lever Inlet Outlet Right Left
Number Position Connection Connection LP-Gas NH3 Operation Operation
Single Flange
A3217AR160 A3217AL160 160 145
A3217AR210 A3217AL210 3” 300# 210 190
3” 300# A3217ARPA A3217ALPA
ANSI RF
A3217AR260 A3217AL260 Right or Left ANSI RF 260 236 A3217RA A3217LA
Modified
A3217AR410 A3217AL410 Flange 410 372 A3217ROA A3217LOA
Flange*
A3217AR510 A3217AL510 510 459
Double Flange
A3217DAR160 A3217DAL160 160 145
A3217DAR210 A3217DAL210 3” 300# 210 190
3” 300# A3217ARPA A3217ALPA
ANSI RF
A3217DAR260 A3217DAL260 Right or Left ANSI RF 260 236 A3217RA A3217LA
Modified
A3217DAR410 A3217DAL410 Flange 410 372 A3217ROA A3217LOA
Flange*
A3217DAR510 A3217DAL510 510 459
* Valve supplied with 16 nuts and 8 studs for mounting.
**Modified bore=4⅝” diameter with 5¾” diameter raised face.

G16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
3” Flanged Internal Valves for Bobtail Delivery Trucks, Transports, and
Large Stationary Storage Tanks

A3217ARPA and A3217ALPA Pneumatic Actuators


These Pneumatic Actuators are designed specifically for use with the
A3217 Series 3” Internal Valves. The diaphragm design provides a
convenient means of opening and closing the valve from a remote
location, using either air or nitrogen.
8”
Features
• Diaphragm type–no seals to leak.

• Easily installed on internal valve “in-line.’’

• Utilizes standard air brake chamber with proven performance over


many years of heavy-duty truck/trailer applications.

• Compatible with existing air interlock systems.


45º
• Operates with pressures of 50-150 psig.

• Thermal Fuse installed complies with DOT thermal protection


requirements.

Materials
Body and Valve Cage.......................... Cadmium Plated Ductile Iron
Seat....................................................... Nickel Chrome Plated Steel
Strainer...................................................................... Stainless Steel
Shaft.......................................................................... Stainless Steel
Pilot Valve Stem........................................................ Stainless Steel
Springs...................................................................... Stainless Steel
Actuator Cam............................................................ Stainless Steel
Lever................................................ Cadmium Plated Carbon Steel
Seat Disc................................................ Resilient Synthetic Rubber
8”
G

A3217A & FA Series


600

500

400
GPM -Propane

300

200

100

0
0.25 0.5 0.75 1 1.5 1.6 1.7 2 2.3 2.5 3 3.5
Drop Through Valve PSI

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G17
4” Flanged Internal Valve for Transports and Large Stationary Storage Tanks
A3219 Series

Application
Designed primarily for LP-Gas and anhydrous ammonia service on
MC331 transport pressure vessels and large stationary storage tanks.
Installation is quick and easy, and it fits in most existing tank flanges.
The valve may be actuated manually or pneumatically.

Use of the A3219RT Remote Thermal Release with this valve is


suggested to provide a remote means of mechanical closure along
with thermal protection, as required by DOT.

Features
Provides More Efficient Operation
• Flow passages designed to allow higher pumping rates without
cavitation or loss of efficiency–-saves time and money. A3219FA
• One piece, stainless steel pilot valve provides more accurate
alignment for dependable operation.
• Remote release lever allows cables to run directly to opposite
ends of vessel without pulleys or tubing.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Temperature range of -40°F to +165°F (-40°C to +73°C) A3219FPA
• MAWP: 400 PSIG(27 Bar)

Protects Your Pump


• Main disc retaining screws are installed from the top down to help
minimize loose screws from entering and damaging the pump.
• Back-up cotter pin is designed to minimize the chance of a
loosened actuator nut and washer from entering and damaging
the pump.
A3219RA
Less Frequent-Easier Maintenance
G • Easily replaceable chrome plated seat insert eliminates need for
expensive remachining of valve body when overhauled.
• Stainless steel screws resist rusting and are easily removed
during valve disassembly.
• Strainer completely covers the top of the valve to help keep out
sediment and foreign material.
• Strainer seats at the top flange of the valve’s seat insert, making
removal of the valve easier.

Durable Construction
A3219FA400W
• Taper pin lock secures the operating shaft to provide for more A3219FA600W
precise, trouble-free actuation.
• Built-in excess flow valve and thermal protection.
• Specify RegO Internal Valves on your next new tank body or Materials
rebuild. Body and Valve Cage.......................... Cadmium Plated Ductile Iron
Handle................................................. Cadmium Plated Ductile Iron
Seat....................................................... Nickel Chrome Plated Steel
Strainer...................................................................... Stainless Steel

10
Stem.......................................................................... Stainless Steel
REGO
Pilot Valve Plug.......................................................... Stainless Steel
Springs...................................................................... Stainless Steel
Roller Actuator.................................. Cadmium Plated Carbon Steel
YEAR Lever Assembly................................ Cadmium Plated Carbon Steel
Seat Disc................................................ Resilient Synthetic Rubber
WARRANTY

Ordering Information
Closing Flow GPM*** Accessories
Part Number* Inlet Connection Outlet Connection Remote Thermal
LP-Gas NH3 Pneumatic Actuator
Release
A3219FA400L 400 360 A3219FPA
A3219RT (2)
A3219FA600L 4” 300# ANSI RF 4” 300# ANSI RF A3219RA
600 540
A3219FA600W Modified Flange** Flange
- A3219W
A3219FA400W 400 360
* Valve supplied with 16 nuts and 8 studs for mounting.
** Modified bore = 5 7/8” diameter with 7” diameter raised face.
*** Other closing flows available

G18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
4” Flanged Internal Valves for Transports and Large Stationary Storage Tanks

Application
A3219FPA Pneumatic Actuator
The A3219FPA Pneumatic Actuator is designed especially for use
with the A3219FA Series Flanged Internal Valves. The diaphragm
type A3219FPA provides a convenient means of opening and closing
the valve from a remote location, using either air or nitrogen, on
LP-Gas and NH3 transport trailers and stationary tanks.

Features
• Diaphragm type–no seals to leak.

• Easily installed on internal valve “in-line.’’

• Utilizes standard brake actuator with time proven performance in


heavy-duty truck/trailer applications.

• Compatible with existing air interlock systems.

• Operate with pressures of 50-150 psig.

• Thermal fuse installed in actuator complies with DOT thermal


protection requirements.

A3219FA600L
700

600

500

400
GPM -Propane

300

200

100

0
0.9 1.8 2 2.5 3 3.5 4 4.2
Drop Through Valve PSI

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G19
Remote Thermal Release for DOT MC331 Pressure Vessel A3219RT

Application
Designed especially for use with Internal Valves installed in DOT
MC331 pressure vessels. The A3219RT provides a remote means
of mechanical closure along with thermal protection, as required by
DOT MC331.
The A3219RT is connected by cable to the internal valve(s) on the A3219RT
vessel. In the event of extreme heat (over 212° F.), the fuse link will
melt, causing the spring to contract and pull the cable. When properly
installed the cable will trip the internal valve release lever(s) allowing
Features
• Meets DOT MC331 requirements.
the connected handle(s) to move to the closed position.
• Easily installed, rugged formed steel bracket has open bottom to
Materials minimize dirt and water build-up.
Body...................................................................... Galvanized Steel
Springs...................................................................... Stainless Steel • Heavy, shouldered pins lock into position.

• Stainless steel spring provides dependable performance with 100


Ordering Information lb. load.
Spring Load Minimum
Number • Heavy-duty chain adapts easily to standard cable and fittings.
Part For Use Release Fully After 4” Required
Number With Temperature Extended Travel By MC331 • Fuse link has 212° F. release temperature.
Internal
A3219RT 212° F. ≈100 lbs. ≈50 lbs. 2 • Adapts easily to standard cables and fittings.
Valves

10
REGO

YEAR
WARRANTY

G
Remote Cable Controls for Internal Valves 3200C and 3200L
Application
The 3200C Remote Cable Kit is designed especially for use with the
3200L Remote Operating Lever to operate internal valves from a
remote location.
The internal valve is opened by pulling back the remote operation
lever and closed by returning the lever to its original position. A
remote release is provided to close the internal valve from a different
remote location.

Features
• Metal construction provides durability in heavy duty applications.

• Toggle action of operating lever allows for quick closure without


extra springs and latches.

• The unique clamping nut and cable clamps provide easy


installation.

• Fuse connections allow internal valves to close if connections are


exposed to fire.
3200L

10
• Versatile design permits installation on bobtails and stationary REGO
tanks at bulk plants.

• Provides necessary remote closure system for bobtails required


by DOT regulation on MC330/MC331 tanks and NFPA #58. YEAR
WARRANTY
Ordering Information
Part
Number Description Contents Materials
Body...................................................................... Galvanized Steel
100 Foot Cable, 6 Cable Clamps, Quick
3200C Remote Cable Kit Springs...................................................................... Stainless Steel
Link, Sign, Fuse Link, Steel Nut and Bolt
3200L Operating Lever Lever Assembly

G20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Threaded Internal Valves For Bobtail Delivery Trucks, Transports
and Stationary Storage Tanks A3213D Series

Application Seat disc fully retained and field replaceable.


Designed primarily for use with LP-Gas and anhydrous ammonia
for liquid withdrawal; vapor transfer or vapor equalization of bobtail Excess flow spring is independent from
delivery trucks, transports, stationary storage tanks, and in-line return spring operation
installations. The valve may be operated manually by cable or
pneumatically.

Features
• May be installed in full and half couplings.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Simple operating lever facilitates easy adaptation of all cable
controls.
• Midway stem position allows for quicker pressure equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• All critical operating components are located in the valve body
inside the container coupling for maximum protection against
physical damage.
• Built-in excess flow valve. A3213D Series
• Return spring returns the valve to the closed position when the
Cam attached with Allen head fastener which is
handle is released. accessed from the ¼” pipe plug on side of the body
• Specify RegO Internal Valves on your next new tank body or when
your tank is rebuilt.
• A3213PA pneumatic actuator provides a convenient means of
opening and closing the valve from a remote location, using either
air or nitrogen for A3213D service valves.
A3213DT
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) A

B
G
F
A3213PA

Materials
Body............................................................................... Ductile Iron A3213RA
Operating Lever............................................. Cadmium Plated Steel
E
Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel A3213TL
Seat Disc................................................ Resilient Synthetic Rubber
D
Shaft Bearing........................................................................... Nylon
A3213D Series
450

10
400
REGO
350
Half Coupling
300 Full Coupling
GPM-Propane

250

YEAR 200

150
WARRANTY
100

50

Ordering Information
0.2 0.5 1.2 2.2 3.6 5.2 7.4
Drop Through Valve PSI

Closing Flow Half Closing Flow Full Vapor Closing


Inlet Outlet Accessories
Coupling (GPM) Coupling (GPM) Flow (SCFH)
Part Number Connection Connections
M.NPT F.NPT 25 PSIG 100 PSIG Pneumatic Thermal
LPG NH3 LPG NH3 Rotary Actuator Electric Actuator
Inlet Inlet Actuator Latch
A3213D150 150 135 125 113 26,900 45,900
A3213D200 200 180 160 144 32,300 55,100
A3213D300 300 270 250 225 50,500 86,500
A3213D400 400 360 325 293 71,400 121,300 A3213RA
3” 3” A3213PA A3213EA A3213TL
A3213DT150* 150 135 125 113 26,900 45,900 A3213OA

A3213DT200* 200 180 160 144 32,300 55,100


A3213DT300* 300 250 250 225 50,500 86,500
A3213DT400* 400 325 325 293 71,400 121,300
* T-body design

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G21
Threaded Internal Valves with Electric Actuator For Bobtail Delivery
Trucks, Transports and Stationary Storage Tanks EA3213D Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia
for liquid withdrawal; vapor transfer or vapor equalization of bobtail
delivery trucks, transports, stationary storage tanks, and in-line
installations.

Features
• One piece body construction.

• Spring loaded V-packing with heavy duty wiper ring on operating


shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Excess flow valve feature
• Return spring forces the valve lever to the closed position when
the power is de-energized.
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position (rapid bleed) allows for quick pressure
equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection.
• Provides a convenient means of electrically opening and closing
the valve from a remote location.
• CSA/UL rated Explosion Proof Enclosure on the actuator.
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC
• Internal Valve is UL Listed and TPED Certified
• Electric Actuator is ATEX Certified
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)
G

Materials
Body............................................................................... Ductile Iron
Operating Lever............................................. Cadmium Plated Steel
Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber
Shaft Bearing........................................................................... Nylon
A3213D Series
450

400

350
Half Coupling
300 Full Coupling
GPM-Propane

10
250
REGO
200

150

100
YEAR
50
WARRANTY 0
0.2 0.5 1.2 2.2 3.6 5.2 7.4

Ordering Information Drop Through Valve PSI

Closing Flow Half Coupling Closing Flow Full Coupling LP-Gas Vapor Capacity** (SCFH/
Inlet Outlet (GPM) (GPM) Propane)
Part Number Connection Connections Voltages
M.NPT F.NPT LPG NH3 LPG NH3 25 PSIG Inlet 100 PSIG Inlet

EA3213D150 150 135 125 113 26,900 45,900


EA3213D200 200 180 160 144 32,300 55,100
EA3213D300 300 270 250 225 50,500 86,500
EA3213D400 400 360 325 293 71,400 121,300
3” 3” 12/24 VDC
EA3213DT150* 150 135 125 113 26,900 45,900
EA3213DT200* 200 180 160 144 32,300 55,100
EA3213DT300* 300 250 250 225 50,500 86,500
EA3213DT400* 400 325 325 293 71,400 121,300
* T-body design
G22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Threaded Internal Valves For Bobtail Delivery Trucks, Transports
and Stationary Storage Tanks A3212 Series

A3212R Series
Application A3212R Series
Designed primarily for use with LP-Gas and anhydrous ammonia
for liquid withdrawal; vapor transfer or vapor equalization of bobtail 300

delivery trucks, transports, stationary storage tanks, and in-line 250


Half Coupling

installations. The valve may be operated manually by cable or

GPM -Propane
200
pneumatically.
150

Features 100
Full Coupling
• May be installed in full and half couplings. 50
• Nylon bearing supported operating shaft provides smooth, easy 0
operation. 1 3 5 7 10
• Simple operating lever facilitates easy adaptation of all cable Drop Through Valve PSI
controls.
• Midway stem position allows for quicker pressure equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff

10
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential REGO
pressure).
• All critical operating components are located in the valve body
inside the container coupling for maximum protection against
physical damage. YEAR
• Built-in excess flow valve. WARRANTY
• Return spring returns the valve to the closed position when the
handle is released.
• Specify RegO Internal Valves on your next new tank body or when
your tank is rebuilt.
• A3213PA pneumatic actuator provides a convenient means of
opening and closing the valve from a remote location, using either
air or nitrogen for both the A3212R & A3213A service valves.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Materials G
Body............................................................................... Ductile Iron
Operating Lever............................................. Cadmium Plated Steel
Stem.......................................................................... Stainless Steel
Springs...................................................................... Stainless Steel
Seat Disc................................................ Resilient Synthetic Rubber A3212R Series
Shaft Bearing........................................................................... Nylon

ROTARY ACTUATOR

A3213RA
OPEN

INLET

Engineered Controls
International, LLC

Rotary
Actuator
Ordering Information
Closing Flow (GPM) Closing Flow (GPM)
Inlet Outlet Accessories
Half Coupling Full Coupling
Part Number Connection Connection A B C
M. NPT F. NPT Thermal Pneumatic Rotary Electric
LP-Gas NH3 LP-Gas NH3
Latch Actuator Actuator Actuator
A3212R 105 2” 411/16”
105 95 65 59
A3212R T105 2” T-body 415/16”
A3212R 175 2” 411/16” 45 A3212RA
2” 175 158 100 90 19/16” 3 /64” A3213TL *A3213PA A3212EA
A3212R T175 2” T-body 415/16” A3212OA
A3212R 250 2” 411/16”
250 225 130 117
A3212R T250 2” T-body 415/16”

* For the old A3212A Series please use the A3212PA Pneumatic Actuator

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G23
Threaded Internal Valves with Electric Actuator For Bobtail Delivery
Trucks, Transports and Stationary Storage Tanks EA3212 Series

Application
Designed primarily for use with LP-Gas and anhydrous ammonia
for liquid withdrawal; vapor transfer or vapor equalization of bobtail
delivery trucks, transports, stationary storage tanks, and in-line
installations.

Features
• One piece body construction.
• Spring loaded V-packing with heavy duty wiper ring on operating
shaft for dependable leak-free construction.
• Nylon bearing supported operating shaft provides smooth, easy
operation.
• Excess flow valve feature
• Return spring forces the valve lever to the closed position when
the power is de-energized.
• All critical operating components are located in the valve body
and inside the container coupling for maximum protection against
damage.
• Midway stem position (rapid bleed) allows for quick pressure
equalization.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Equipped with 212° F, UL listed fuse link for thermal protection.
• Provides a convenient means of electrically opening and closing
the valve from a remote location.
• CSA/UL rated Explosion Proof Enclosure on the actuator.
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC
• Internal Valve is UL Listed and TPED Certified
• Electric Actuator is ATEX Certified EA3212R Series
• Temperature range of -40°F to +165°F (-40°C to +73°C)
G • MAWP: 400 PSIG(27 Bar)

Materials
Body............................................................................... Ductile Iron
Operating Lever............................................. Cadmium Plated Steel A3212R Series
Stem.......................................................................... Stainless Steel 300
Springs...................................................................... Stainless Steel 250
Half Coupling

Seat Disc................................................ Resilient Synthetic Rubber


GPM -Propane

200
Shaft Bearing........................................................................... Nylon
150

100
Full Coupling
50

0
1 3 5 7 10
Drop Through Valve PSI

10
REGO

YEAR
WARRANTY

Ordering Information
Closing Flow (GPM) Closing Flow (GPM)
Inlet Outlet LP-Gas Vapor Capacity (SCFH/Propane)
Half Coupling Full Coupling
Part Number Connection Connection Voltages
M. NPT F. NPT LP-Gas NH3 LP-Gas NH3 25 PSIG 100 PSIG

EA3212R105 2”
105 95 65 59 42,975 73,048
EA3212RT105 2” T-body
EA3212R175 2”
2” 12/24 VDC 175 158 100 90 48,169 81,876
EA3212RT175 2” T-body
EA3212R250 2”
250 225 130 117 57,067 97,001
EA3212RT250 2” T-body

G24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports and
Large Stationary Storage Tanks A7883FK

Application
Designed primarily for LP-Gas and anhydrous ammonia liquid
withdrawal on MC331 bobtail delivery trucks, transports and large
stationary storage containers with flanged connections. The valve is
fully automatic, opening and closing as the pump is turned on or off.

Features
Fully Automatic
• Operates on pressure differential from the pump to open and
close.
• Automatically closes should downstream line rupture causing loss
of pump differential pressure required to keep the valve open.
• Problems of improperly sized excess flow valves slugging shut
during liquid transfer are eliminated.

Faster Unloading
• Straight through flow design provides minimum pressure drop and
large flow capacity to the pump, resulting in higher flow rates and
greater pump efficiency.
• Unloading is quicker and turn-around faster to provide more
profitable operation.
A7883FK
Greater Protection
• Fully automatic operation virtually eliminates operator errors such
as forgetting to close the valve after product transfer.
• Fully internal design reduces possibility of spillage that may result
from a collision.
• Built-in visual indicator lets the operator know whether the valve
seat is in the open or closed position.
• Never a cable problem. These valves cannot be held open by wire
or any other means as the valve will not close as expected when
the pump is shut-off.
G
Less Maintenance
• Easily replaceable, high efficiency external filter removes
contaminants as small as 20 microns. Filter virtually eliminates
orifice clogging, excessive internal filter maintenance and service
downtime.
• No need to check or replace air lines, cables or cable connections.

Economical
• Completely equipped with mounting bolts, flange gaskets, quick
acting valve and filter - all in one purchase price.
• No need to purchase additional mounting equipment or actuating
accessories.
• Specify RegO Internal Valves on your next new tank body or when
your tank is rebuilt.

• Temperature range of -40°F to +165°F (-40°C to +73°C)


• MAWP: 400 PSIG(27 Bar)

Materials
Body................................................................................. Cast Steel
Valve Stem................................................................ Stainless Steel

10
Operating Stem......................................................... Stainless Steel REGO
Piston................................................................................ Aluminum
Cylinder..................................................................... Stainless Steel
Screen....................................................................... Stainless Steel
Seats...................................................... Resilient Synthetic Rubber YEAR
WARRANTY

Ordering Information
Accessories (included with Flomatic®)
Part Inlet Connection ANSI Outlet Connection Strainer Base Overall Height Height from Indicator
Number Flange ANSI Flange Width Width (Approx.) to Base Filter 3-Way Valve
A7883FK* 3”-300#** 3”-300# 4¾” 8¼” 10⅞” 413⁄16” A7884-201 A7853A
* Supplied with A7853A 3-way valve, A7884-201 filter, studs, nuts and gaskets.
** With 413⁄16” diameter bore.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G25
Flomatic® Internal Valve Operation

General Information
RegO piston type Flomatic Internal Valves are normally closed and
use pressure differential to provide completely automatic service.
Mounted directly between the tank body and pump, the Flomatic®
uses the pressure differential developed by the pump to open the
valve and it closes automatically when the differential no longer
exists.

This means the RegO Flomatic opens when the pump is on and
closes when the pump is shut off – fully automatic.

3. Pump On – Valve Open


The force below the pilot stem forces the piston up to open the valve;
rotating the INDICATOR SLOT to its vertical (valve open) position.
Pump differential pressure in area D holds the PILOT STEM and
PISTON open. Approximately 20 psig pump differential pressure is
required to open the valve; approximately 8 psig differential pressure
1. Normally Closed will hold the valve open.
When the valve is closed, liquid flows into the INLET PORTS, through
a channel in the PISTON, and into area A. It also flows down through
the PRIMING CHANNEL in the valve body, into area B beneath the
valve seat, and into area C to prime the PUMP.

4. Pump Off – Valve Closes


With the pump shut off, the pressure in area D which holds the
2. Pump On – Valve Opening valve open, bleeds out through the #60 DRILL ORIFICE. This loss
When the pump is started, differential pressure transmits through the of pressure permits the SPRING to push the PILOT STEM down to
¼” piping into chamber D. lifting the PILOT STEM. This opens the reseat at point E. Since pressures are equal above and below the
seat between the stem and piston at E. Pump suction then evacuates PISTON, with no sustaining pressure in area D, the SPRING forces
the tank pressure in area A, which becomes equal to the pump the valve closed. The INDICATOR SLOT rotates to the horizontal
suction pressure. (valve closed) position.

G26 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
¼” Three-Way Quick-Acting Valve
A7853A

10
REGO

Flomatic Valve YEAR A7853A ¼” Three-Way


Typical Installation WARRANTY Quick-Acting Valve

Tank Flange
Flomatic filter
Tank Gasket Flange
(To Pump Station
¼” Vent Line
¼“ High Tee
Pressure
Hose
G
A7853PAF

Pump
Control Cable
(with Fuse link A7853PAL
and return spring)

A7853A Three Way Valve

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C) A7853PA
• MAWP: 400 PSIG(27 Bar)

Ordering Information
Accessories
Part Number Flange Type A B C D Pneumatic Actuator Electric Actuator 3-Way Valve
T-1 Steel A7853PAF
A7853A* 4 / ”
13 16 5¾” 6⅝” 8¼” A7853EA A7853PA
Carbon Steel A7853PAL
* Supplied with A7853A 3-way valve, A7884-201 filter, studs, nuts and gaskets.
** With 413⁄16” diameter bore.
.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G27
Electrically Actuated 3 way valve
EA7853A

Application
The EA7853A 3-way quick acting valve controls the fluid exchange
between three separate transfer lines. For better control, the
3-way valve is paired with an electric actuator which provides a
safe, easy way to open and close the valve from a remote location.

Features
• Dual fail-safe actuator with a CSA/UL rated explosion-proof
enclosure

• Spring return with handle

• Fusible link and electronic thermal cut-off.

• Ensures automatic valve shut off when power supply is lost or


turned off.

• Provides a convenient means of electrically switching the valve


from a remote location.

• CSA/UL rated Explosion Proof Enclosure on the actuator.

• Class I, Div 1 Groups B, C, D, / T6 EA7853A

• 12-24VDC

• 3 Way Valve is UL Listed and TPED Certified

• Electric Actuator is ATEX Certified

G
Materials
Body............................................................................... Ductile Iron
Flange........................................................................... Carbon Steel

Ordering Information
Part Number Flange Type Voltages
T-1 Steel
EA7853A 12/24 VDC
Carbon Steel
* Supplied with A7853A 3-way valve, A7884-201 filter, studs, nuts and gaskets.
** With 413⁄16” diameter bore.
*** With 513⁄16” diameter bore.

G28 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
On-The-Job Service Guide for the Flomatic® Valve

Introduction
Efficient, profitable transport and delivery truck operations depend on
keeping the equipment working safely and efficiently under changing
conditions. It is important to know how to eliminate expensive delays
by handling unloading problems as they arise.

The purpose of this technical guide is to provide basic information on


the Flomatic® valve, along with simple, appropriate steps to follow in
the event things go wrong.

The Flomatic® valve is mounted on the bottom of your transport or


delivery truck tank, with the pump mounted immediately downstream.
When the pump starts to push the liquid down the piping, the
Flomatic® Valve opens automatically, allowing you to unload the tank,
and closes when the pump stops pushing. It takes at least 20 pounds
per square inch of “push’’ at the pump to open the valve.

Your flanged Flomatic® valve has an indicating shaft on it that


shows whether it’s open or closed (Figure 1). If the indicating shaft is
horizontal, the valve is closed. If it’s vertical, the valve is open.

A threaded type, diaphragm-operated Flomatic® valve has an


indicating shaft on the bottom, covered by a clear plastic hood.
The indicating shaft projects down when the valve is closed and is
concealed when the valve is open (Figure 2).

Important Facts About Pressure


When handling propane or anhydrous ammonia, storage and
transport tank pressures vary from about 20 pounds per square inch
or less when it’s cold to 200 pounds per square inch or more in hot
weather (Figure 3). If you’re hauling butane, tank pressures will be 50
pounds per square inch or less.
G
The transport or delivery truck tank pressure may be higher than the
storage tank pressure when you are ready to unload (Figure 4). This
is because your rig may have been freshly loaded at the terminal or
bulk plant without a vapor equalizing line and hasn’t had time to get
back to normal. Also, the storage tank pressure tends to drop when a
lot of LP-Gas is being used.

Troubleshooting on the Job


O.K. So you follow your procedures, hook up your hoses, open the
required valves and start your pump. The indicating shaft on the
Flomatic® valve moves to the open position and the liquid goes in to
storage. Great! You’re happy and so is the boss, and so are we.

But, let’s say you do these things, start the pump and the liquid
doesn’t move. Now, how do you find out what is wrong?

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G29
On-The-Job Service Guide for the Flomatic® Valve

Step 1 6. Ice in the system may prevent proper operation, as will a


Immediately shut down the pump so you don’t cause possible collapsed or kinked sensing line or a clogged sensing line filter.
damage to the seals or valves. Next: If you found the trouble within STEP 1, just start the pump and
continue unloading, If not, proceed accordingly.
1. Check all manual valves in the system to make certain they
are open or closed as required for proper operation. a. New Models with T-handle: To adjust to the proper
position, push in the end of the valve stem and tighten the
2. Check the liquid level in the transport or delivery tank. If the needle valve clockwise until it seats. Then, turn
level is low, it may slow the transfer rate. counterclockwise 1½ turns.

3. Check to ensure that the pump rotates normally when power b. Old Models with Plug: To adjust to the proper position,
is applied. If not, inspect and repair as needed the power takeoff, carefully remove the plug. A small amount of liquid
universal joints, drive shaft and clutch, etc. LP-Gas may be discharged when plug is loosened. Insert
a small screwdriver and tighten the needle valve
4. Make sure the lever is straight out on the ¼” operating valve clockwise until it seats. Then turn it counterclockwise
in the line between the pump discharge line and the Flomatic® 1 turn only. CAUTION: Do not open needle valve
valve (Figure 5). If it isn’t, the Flomatic® valve will remain closed. more than 1 turn as it might blow out!

5. Make certain the priming valve on the side of the Flomatic® c. Threaded Models with Internal Priming Channel. The
valve is open (Figure 6). internal priming channel normally self-actuates. To be sure
the system is primed, remove the plastic hood and push
the travel indicator up about ⅛” and hold for at least 15 seconds.

For Transport Trailer Trucks Only (Figure 7a)


1. Check the difference between the pressure
in your transport and the storage tank. If there’s
15 or 20 pounds per square inch more pressure
in the transport tank than in the storage tank,
chances are the Flomatic® valve won’t open.
This is because the pump can’t develop enough
“push.’’

If you have a good bypass valve on your rig


to send the extra liquid back into the tank, you
can merely close the liquid shut-off valve in the
discharge line and restart your pump (Figure 8a).
Now, the Flomatic® indicating shaft should move
to the open position (see Figures 1 and 2).

2. Slowly open the liquid shut-off valve in the


discharge line and the liquid will start to move
out of the transport. If the Flomatic® valve
indicating shaft starts to move toward the closed
position once you’ve opened this liquid shut-off
valve all the way, throttle the valve for a while
until the transport tank pressure drops to where
the Flomatic® valve indicating shaft will stay
open. Then, open the liquid shut-off valve all the
Figure 7a. Unloading Diagram of Transport Trailer Truck way until you finish unloading.
The liquid flows out of the transport tank through the Flomatic® valve, into the pump and through the delivery hose to the storage tank. The vapor line
allows vapor to flow from storage back to the transport so that the storage tank pressure won’t build up too much and make the pump work harder
than necessary.

G30 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
On-The-Job Service Guide for the Flomatic® Valve

3. If your pump system doesn’t have a


bypass valve, the liquid shut-off valve in
the discharge line should be left partially
open when you restart the pump. Just be
sure that the pump is pushing at least 20
pounds per square inch, so the Flomatic®
valve can open.

Don’t worry about how much it may slow


up your loading speed when you pinch
down the liquid shut-off valve to get the
Flomatic® valve open. Your pump is
running at constant RPM and will move Figure 8a. Unloading Diagram of Transport Trailer Truck with Back-to-tank Bypass Valve
liquid at almost the same rate, even when You must have a separate back-to-tank bypass valve if the pump is to be run with the liquid
pushing harder. (It’s a lot like using engine shut-off valve closed.
braking on a downhill grade, except, in this
case, the pump keeps the liquid moving at
a constant flow rate.)

For Delivery Trucks Only (Figure 7b)

1. Check the pump bypass piping. If


your truck is equipped with a manual
bypass valve, close it and try the pump G
again. (Figure 8b). If the Flomatic®
valve indicating shaft moves to the open
position, the problem is that the pump
can’t develop 20 pounds per square inch
or more to “push’’ open the Flomatic®
valve with the bypass valve open. You can
prevent this in the future by not opening
the manual bypass valve too wide.
Figure 7b. Unloading Diagram of Delivery Truck
2. If the delivery truck is not equipped The liquid flows out of the truck tank, through the Flomatic® valve and into the pump, where
with a manual bypass valve, merely start it is then pushed through the meter and delivery hose into the storage tank. The liquid
the pump. Slowly close the shut-off valve normally enters the vapor space of the storage tank to minimize pressure buildup, so a
between the back-to-tank bypass valve vapor equalizing line is usually not needed. The back-to-tank bypass valve opens to divert
and tank. If the Flomatic® valve indicating excess pump capacity back to the truck tank, preventing the pump from creating too much
shaft moves to the open position as you pressure.
close the valve, the back-to-tank bypass
valve may be stuck open, adjusted too low,
or the spring may be broken. CAUTION:
Don’t close the shut-off valve all the
way, because excessive pressures and
pump damage may occur.

3. If the Flomatic® valve indicating shaft


remains in the closed position, the problem
is either in the pump or the Flomatic®
valve.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G31
On-The-Job Service Guide for the Flomatic® Valve

USE EXTREME CARE AT ALL TIMES WHEN WORKING AROUND YOUR VEHICLE!
Watch out for drive shafts and moving parts. It is common knowledge that serious injury
can result if any part of one’s body or clothing is caught in moving machinery.

If you manually open the Flomatic® valve, you are responsible for safely unloading the
liquid and closing the valve when you’re through. If this procedure is being followed,
under no circumstances must the valve be left unattended. The valve must never be
permanently held in the open position.

If you are not able to cause the Flomatic® valve indicating shaft to
move to the open position after completing the preceding steps, a
complete detailed diagnosis will have to be made.

In the meantime, you can actuate the flanged Flomatic® valve by


using a special wrench and attempt to unload manually (Figure 9).

If you still can’t unload by following the preceding steps, it is


suggested that you unload by an alternate method, such as
through the valve normally used for liquid filling.

In any event, if you haven’t solved the problem and the unit still
doesn’t operate properly, immediately take it out of service, have a
complete analysis made and repair as needed.
G
Be sure to obtain and keep available for quick referral the
Manufacturers’ Operation and Service Manuals for the valves,
pump, meter and all operating equipment in the system.

G32 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Pumping System Troubleshooting Guide

Introduction
Most LP-Gas and anhydrous ammonia systems use pumps to This would allow pressure gauges to be put in easily without
move liquid from one location to another. Unloading transport trailer removing the LP-Gas or anhydrous ammonia from the system
tanks into plant storage, loading delivery trucks, filling bulk tanks, at the time trouble occurs, saving a lot of time and unnecessary
engine fuel tanks, portable cylinders, etc. and pressurizing LP-Gas expense. Pressure gauges should be installed temporarily at
vaporizers are only a few of many such applications. A well-designed the time the system is first installed, and pressure readings
and properly installed pumping system will perform well for some recorded while the system is working properly. Then, in many
time, but eventually problems occur requiring attention. cases, merely comparing pressures with original readings may
tell what the trouble is.
Finding out what is wrong, and getting it working again, can be
a time-consuming and confusing experience, unless one knows NOTE: The figure below shows where pressure gauges should
clearly how to proceed. be installed. Pressure gauge readings from the original tests
should be recorded for each gauge.
The purpose for this technical guide is to provide simple, step-by-
step guidelines for correcting LP-Gas and anhydrous ammonia It is recommended that the pressure gauges not be used
pumping difficulties. continuously, because vibrations and the ravages of weather
cause their damage or ruin. Therefore, as soon as the initial
The procedure includes a preliminary checklist to help find out if tests are complete, it is best to (1) close the shutoff valves,
the difficulty can be corrected without taking anything apart. Then, (2) remove the gauges, (3) plug the valves and (4) keep the
it shows how to zero in on more serious problems by using a few gauges in a safe place, ready for troubleshooting when really
pressure gauges to pinpoint the cause. needed. It is easier to diagnose a problem if the original test
results are available, but don’t panic if they aren’t. You can still
It is recommended that the pumping system be equipped for easy solve the problem without this information, but it requires more
pressure gauge installation before trouble occurs. Small manual time and effort.
shutoff valves can be installed at proper locations, with plugs
inserted in the outlets.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO G33
Pumping System Troubleshooting Guide

Be sure to obtain and keep available for quick referral the other hand, if you have done all of this and still haven’t worked out
Manufacturer’s Operation and Service Manuals for the valves, pump, your problem. feel free to call your local distributor or RegO
meter and all operating equipment in the system.
direct. We will do our best to help. Perhaps, between us, we will be
To avoid delays, maintain a complete stock of recommended spare able to solve your problem and add something new to the procedure
parts on hand for quick repairs. which could help everyone in the future.

Follow the steps as shown. Don’t assume the answer is known


beforehand, or skip any applicable steps. Rather, be thorough and
methodical and in most instances, you will solve the problem. On the

G34 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section H
Adapters, Connectors and Fittings H H

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
H warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

H2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. H
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H3
Extended Type Hose Couplings for Vapor and Liquid Service
A7571 and A7575 Series

Application
Designed especially for liquid filling and vapor equalization of LP-Gas
and anhydrous ammonia. The limited travel of the handle on the
tailpiece minimizes spin-off, encouraging cautious removal to properly
bleed off trapped product to ensure closure of the filler valve and
hose end valve. The ACME threads are machined on a rugged steel
insert which is permanently cast in the aluminum handle, providing for
durability under repeated use.

Features
• Lightweight aluminum handle is contoured and ribbed for added
comfort, easy handling allows for easy make-up.

• Free swivel action between tailpiece and handle allows for easy
make-up.

• Simplified design eliminates an extra joint and provides smooth,


uninterrupted flow.

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

A7571 Series

Materials
Handle.............................................................................. Aluminium
ACME Threads.................................................................. Steel Inlet
Restraining Ring........................................................ Stainless Steel
H

10
REGO

YEAR
WARRANTY

A7575 Series

Ordering Information
A. B. C.
Part Type Hose Connection Coupling Connection Approx.
Number of Service (M. NPT) (F. ACME) Length
A7575L2* ½”
A7575L3 ¾”
Liquid 1¾”
A7575L4 1”
7”
A7575L5** 1¼”
A7571LA ½”
Vapor 1¼”
A7571LB ¾”
* Includes 7199-33 adapter, shipped loose.
** Includes A7575L5-1 adapter, shipped loose.

H4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Short Type Hose Couplings for Vapor and Liquid Service
3171, 3175, 3181, 3185 and 3195 Series

3175 Series A3185 Series

Style A Style B
For Liquid Filling For Liquid Filling

3171A Series 3191 Series


H
Style C Style D
For Vapor Equalizing For Vapor Equalizing

10
REGO

YEAR
WARRANTY

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

Ordering Information
A. B. C. D. E.
Part Hose Connection Coupling Connection Tailpiece Hose End Overall
Number Material Style (M. NPT) (F. ACME) Bore To Nut Length
3175B ½” ⁄ ”
35 64

3175 A ¾” 1¾” ¾” 113⁄16” 211⁄16”


Brass
3175A 1” 15⁄16”

3185 1¼” 2¼” 13⁄16” 211⁄16” 3¾”


Brass Nut & Steel B
3195 2” 3¼” ⅞” 2¼” 3⅝”
Nipple
A3175 ¾” ¾” 2” 2⅞”
A 1¾”
A3175A 1” ⅞” 2¼” 3⅛”
Steel
A3185 1¼” 2¼” 1¼” 2⅛” 33⁄16”
B
A3195 2” 3¼” 1⅞” 2¼” 3⅝”
3171 ⅜” ⅜”
1¼” 117⁄32” 213⁄32”
3171A ½” 31⁄64”
C
3181 Brass ¾” ¾” 13⁄16” 211⁄16”
1¾”
3181A 1” ¾” 1⅞” 2¾”
3191 D 1¼” 2¼” 13⁄16” 2⅛” 33⁄16”

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H5
ACME Check Connectors for Lift Trucks
7141F and 7141M

Application

10
These brass connectors are especially designed to join the carburetor
fuel line to the service valve on lift truck cylinders. Sturdy, long lasting REGO
ACME threads allow quick, hand-tight assembly that provides for
quick and simple cylinder replacement. Back checks automatically
close in each connector when disconnected.
YEAR
The 7141M couples directly to the service valve. An integral O-ring is WARRANTY
designed to seal before the internal check opens, aiding in product
loss prevention. A gasket at the ACME thread is a secondary seal
when the connectors are tightened together. The connector fits RegO
lift truck cylinder filling adapters for fast, convenient filling.

The 7141F accepts fuel line adapter and couples directly to the 7141M 7141F
7141M. The O-ring seal in the 7141M is designed to seal before the
internal check opens to allow product to pass through the connection.
The knurled coupling eases threading and the ACME threads provide
rapid effortless make-up, even against LP-Gas pressure.

NOTE: Refer to the “Cylinder and Service Valves” section of the


L-500 catalog for additional information.

Ordering Information
Protective Cap*
A. B.
Part Number Application Inlet Outlet Rubber Brass
7141M Service Valve ⅜” F. NPT 1¼” M. ACME 7141M-40 7141FP
7141F Fuel Line 1¼” F. ACME ¼” F. NPT - -
* Recommended to minimize foreign material entering valves which could result in leakage.

Unloading Adapters for Container Evacuation 3119A, 3120 and 3121


H Application
Designed to provide an efficient means of evacuating an LP-Gas
container for relocation or repair. They thread directly onto the 1¾”
ACME male hose connection of RegO Filler Valves used on RegO
Double Check Filler Valves and Multivalve® assemblies.

The unloading adapters can be used to withdraw liquid provided the


container is equipped with a dip pipe extending from the filler valve to
the bottom of the container.

Features
• Available in either angle or in-line type configurations.

• Built-in vent valve provides for a controlled release of gas which


may be trapped within the unit after use and also helps to indicate 3119A
closure of the Filler Valve.

• Integral plunger has two different lengths of travel, ¼” and ½”, 3120
depending on which way the lever is turned. Can be used with all
RegO Filler Valves.

10
REGO

YEAR
WARRANTY
Materials
Body............................................................................... Brass
Plunger............................................................................ Steel
3121
Ordering Information
Part Number Style A. Filler Valve Connection B. Hose Connection
3119A In-Line 1¾” M. ACME
3120 1 ¾” F. ACME
Angle ¾” F. NPT
3121

H6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Left Hand Thread ACME Connectors for Vapor Withdrawal Industrial
Cylinders 7142LF and 7142LM

Application
These brass connectors are especially designed to join the carburetor
vapor fuel line to the service valve on industrial cylinders especially
designed for and used on propane fueled lawn mowers. Sturdy
long lasting ACME left hand threads provides for quick hand tight
assembly that provides for quick and simple cylinder replacement.

Features
• The 7142LM couples directly to the service valve.

• An integral O-ring is designed to seal before the internal check


opens, aiding in product loss prevention.
7142LM
• A gasket at the ACME thread when the connectors are tightened
together.

• The 7142LF accepts the vapor fuel line adapter and couples
directly with the 7142LM.

• The O-ring seal in the 7142LM is designed to seal before the


internal check opens to allow product to pass through the
connection.

• The knurled coupling nut proves for easy make-up even against
LP-Gas vapor pressure.

Lines across wrench flats indicate left


hand thread male ACME connection.

10
REGO

7142LF
YEAR
WARRANTY

Solid line around coupling


nut indicates left hand thread
female ACME connection.
Ordering Information
Part Number Application Inlet Outlet Protective Cap
7142LM Vapor Service Valve ⅜” F.NPT 1¼” M.ACME –left hand 7141M-40
7142LF Vapor Fuel Line 1¼” F.ACME –left hand ¼” F.NPT -

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H7
Filler Hose Adapters
3179B, 7577V and 7576

These adapters are designed with minimal flow restriction and


recommended for use on the outlet of the LP-Gas delivery truck filler
hose. If the controlled bleed off of the connection indicates the filler
valve on the tank being filled has failed to close, the hose adapter
should be left in place on the filler valve and disconnection should
3179A be made at the regular filler hose coupling. (Repair of the filler valve
must be made as soon as possible). An integral check valve in these
adapters helps prevent further loss of product. The standard filler
valve cap should be attached to these adapters when left on the
container.

Ordering Information
Built-in Vent A Filler Valve B Hose
Part Number
Valve Connection Connection
7577V Yes
3179A
No 1¾” F. ACME 1¾” M. ACME
3179B 3179B
7576 Yes

10
REGO

YEAR
WARRANTY

H
4.0

4.1

7577V

7576

POL Plugs

10
10538P
(Has hole for attaching REGO
wire to prevent loss of
plug)

YEAR
3705RC
WARRANTY W/Chain & Ring

N970P
Highly recommended for installation in LP-Gas cylinder valve POL Ordering Information
outlets whenever the service line is disconnected or when the cylinder
Part
is being transported.
Number Material Connection

When properly installed, the POL plug is designed to prevent N970P Cycolac
M. POL
contamination of the valve outlet and guards against product leakage 10538P
Brass (CGA 510)
if the cylinder valve is accidentally opened. 3705RC

H8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Caps and Plugs

Ordering Information
Cap With Chain & Ring
Part Ring Fits Pipe Size Cap Only Part Thread
Number Up To: Number Material Connection
1708C POL Cap
3144-91 3144-9P 1¼” F. ACME
¾”
3174-91 ABS
3174-9P 7141FP Cap Plug
3174-93 1¾” F. ACME
1¼”
A8016-93 A8016-9P Nylon
1708C ¾” F. POL (CGA 510)
7141FP - Brass 1¼” F. ACME
3175P 1¼”
- 1¾” F. ACME
A3175P Steel
3184-90 - 2¼” F. ACME CGA 510
Brass
3194-90 3¼” F. ACME 3194-90G
A3184-90 - 2¼” F. ACME ACME Cap with Stainless
- Steel
A3194-90 3¼” F. ACME Steel Flange
907FP 1” 115/16” F. ACME
3194-90G -
3194-90GS
Brass
3194-91L
3194-91S -
3¼” ACME
3194-91V Adjustable Cable 907FP
A3194-91L
A3194-91S Steel
A3194-91V

3175P Cap Plug

2”
H

10
3194-91L REGO
3144-90
L=Liquid (Red) Metal Cap
S=Spray Fill (Yellow)
V=Vapor (Yellow) YEAR
WARRANTY 15/16”

A3175P
3194-90GS

3194-91 1¼”

ACME Plugs
Specifically designed to withstand the everyday abuse given to hose
end valves on delivery trucks and hose end couplings on risers in
bulk plants, these rugged plugs protect the coupling tip as well as
prevent the entrance of dirt, dust, snow and rain. They also prevent
possible gas contamination from these same sources. The heavily
ribbed outer surface permits hand-tight make-up.

These plugs are available in a choice of four sizes which may be


used with liquid as well as vapor type couplings. As a convenience, C5763N
the nylon plugs have a retaining chain and ring to prevent loss during Ordering Information
a transfer operation. A
Part Number Material (M. ACME) Chain & Ring Fits Pipe Size Up To:
All are suitable for LPG or anhydrous ammonia service except the C5763N 1¼” ¾”
Nylon

10
brass 5765PR, which is for LP-Gas only. REGO C5765N 1¼”
1¾”
5765PR Brass Not Applicable
Not intended for use as pressure closures. C5767N 2¼” 1¼”
YEAR Nylon
C5769N 3¼” 2”
WARRANTY

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H9
Reducers and ACME Adapters

Ordering Information Features


F. ACME M. ACME • Temperature range of -40°F to +165°F (-40°C to +73°C)
Part Number Material
Connection Connection • MAWP: 400 PSIG(27 Bar)

10
5774 2¼” 1¾” REGO
Brass
5776 3¼” 1¾”
A5776 Steel 3¼” 1¾” YEAR
WARRANTY
A5777* 3¼” 1¾”
Brass
5778 3¼” 2¼”
* Equipped with Stainless Steel Flange
A5776
Reducer Coupling
Ordering Information
For Spare
D Gasket
Part A B C Overall E Order
Number Material M. ACME F.NPT Hex Length Diameter Part No.
5764A ¼” 1¾” / ”
13 32

5764B ⅜” 123/32” / ”
9 16 5778
5764C 1¾” ½” 1¾” 1¼” 11/16” A2697-20R D
5764D ¾” 19/32”
/ ”
29 32
5764E Brass 1” 15/16”
5766E 1” 1/ ” 3 32
2¼” 2¼” 25/8” A3184-8R
5766F 1¼” 1⅜”
A B C
5768G 1½” 111/16” E
3¼” 3¼” 1¾” A3194-8R
5768H 2” 123/25”
A5764D ¾”
1¾” 1¾” 23/16” ⅞” A2697-20R
A5764E Steel 1”
A5768H 3¼” 2” 3¼” 113/16” 115/16” A3194-8R
Gasket (Furnished with adapter)
H Ordering Information ACME x Female NPT
D For Spare
Part A B C Overall E Gasket Order
Number Material M. ACME M. NPT Hex Length Diameter Part No. D
5763D 1¼” ¾” 1¼” 1¾” ½” A2797-20R
5765D ¾” 123/32”
5765E 1¾” 1” 1¾” / ”
29 32 A2697-20R
23/32”
5765F 1¼” A
Brass E B C
5767F 1¼” 13/16””
2¼” 2⅜”
5767G 2¼” 1½” 1⅜” A3184-8R
5767H 2” 2⅜” 27/16” 125/64”
5769K 3¼” 3” 3½” 3⅝” 2⅛” A3194-8R
A5765C ½” 17/32”
Gasket (Furnished with adapter)
A5765D ¾” 11/16”
1¾” 1¾” 2/ ”
3 16 A2697-20R ACME x Male NPT
A5765E 1”
/ ”
57 64
A5765F Steel 1¼” C
A5767F 2¼” 1¼” 2¼” 2⅜” 1¼” A3184-8R
A5769H 2” 3¼” 2⅞”
3¼” 115/16” A3194-8R
A5769K 3” 4” 313/16”
A D A B
Ordering Information
C For Spare Gasket
Part A B Overall D Order
Number Material M. ACME Hex Length Diameter Part No.
5765M 1¾” 1¾” 21/16” 29/32” A2697-20R Gasket (Furnished with adapter)
C
5767M Brass 2¼” 2¼” 25/16” 125/64” A3184-8R ACME x ACME
5769M 3¼” 3¼” 2¾” 115/16” A3194-8R

Ordering Information
D B A
C For Spare Gasket
Part A B Overall D Order
Number Material M. ACME F. UNC Length Diameter Part No.
A5764W Steel
1¾” 3/8”xx - 16* 1¼” 1¾” 2697-20 ACME x Miscellaneous
5764W Brass
(Recommended for securing
* 3⁄8” -16 UNC Thread. hose-end valve when not in use).

H10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
ACME Hose Couplings for Liquid or Vapor Service with Integral Screen
3195S and A3195S

10
Application REGO
The 3195S/A3195S Hose Couplings are designed to prevent
debris from entering and impeding the action of valves and
components in LPG piping systems at bulk and industrial plants.
YEAR
Features WARRANTY
• Meets NFPA 58 requirements for liquid transfer.
• Stainless steel screen installed in the tail piece of the hose
coupling.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

3195S
Materials
A3195
Body.................................Ductile iron Nut & Cadmium-Plated Nipple

A3195S
Body.................................Ductile iron Nut & Cadmium-Plated Nipple
Strainer......................................................300 Series Stainless Steel Style B
For Liquid Filling
Ordering Information
A. B. C. D. E.
Part Hose Connection Coupling Connection Tailpiece Hose End Overall
Number Material Style (M. NPT) (F. ACME) Bore To Nut Length
Brass Nut & Steel
3195S
Nipple B 2” 3¼” 1⅞” 2¼” 3⅝”
A3195S Steel

3¼” M.ACME X M.NPT Adapter with Vent Valve & Integral Screen 5769 H
Application
Designed to prevent debris from impeding the action of valves and
components of LPG piping systems at bulk plants and industrial
plants.
"C" LENGTH SEE TABLE "C" LENGTH SEE TABLE
SEE TABLE FOR HEX SIZE SEE TABLE FOR HEX SIZE

Features (WEEP
HOLE)
(WEEP
HOLE)
(WEEP
HOLE)
• Meets NFPA 58 requirements for liquid transfer
• Stainless steel screen
• Vent valve available in brass or stainless steel 5769HVB
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Materials
Body........................................................................................ Brass
Screen....................................................................... Stainless Steel
Gasket.................................................................... Resilient Rubber
B

10
REGO A A
B
ECII

STYLE 1 STYLE 2

YEAR
WARRANTY

Ordering Information
Part “C
Number Style Gasket Qty Vent Valve Hex Size Thread "A" Thread "B" Length
5769H 3¼” 2” M.NPT 2.875
-
5769K 1 1
3½” 3” M.NPT 3.625
5769KVB 3165CBT
5769M 2 2 - 3¼" ACME 3¼” ACME 2.750
5769HVB 3165CBT
3¼”
5768HVSS 1 1 TSS3169 2” M.NPT 3.150
5769HVP Unplugged

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H11
Low Emission ACME Connector For Transports and Bobtails
6588LE & 6589LE

Application
Designed to provide fast filling of bobtails, transports and large
bulk storage tanks while providing for low emission of LPG when
disconnecting.

Features
• 3¼” Male Acme Connector with reduced emissions, 90% less than
current RegO ACME adapters.

• 10.5 cubic centimeters of liquid discharged at disconnect

• UL Listed as a Filler Valve.

• Safety groove is designed to shear below ACME threads leaving


the valve seat closed and unaffected if the vehicle pulls away with
the hose connected.

• Seat disc is made of synthetic composition and is mechanically


held in place by a seat disc retainer.

• Stainless Steel return spring.

• One- piece poppet stem for smooth operation.

• Will connect to any standard female 3¼” ACME adapter.

• Hydrostatic relief valve included (3125L).

• Temperature range of -40°F to +165°F (-40°C to +73°C)

• MAWP: 250 PSIG(17 Bar)

Materials
Upper Body............................................................................. Brass
Lower Body............................................................................. Brass 6588 Series
Poppet & Stem Assembly........................................................ Brass
Spring........................................................................ Stainless Steel
Gasket.................................................... Resilient Synthetic Rubber
Seat Disc................................................ Resilient Synthetic Rubber

10
REGO

YEAR
WARRANTY

Ordering Information
Outlet Hydrostatic Propane Capacity at Various Differential Pressures (GPM)
ACME Connection Wrench Relief
Part Number Connection M.NPT Flats Valve 5 PSIG 10 PSIG 25 PSIG
6588LE 3¼” 2” 3125L
3½” 138 223 349
6589LE 3¼” 3” 3125L

H12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Male POL Swivel Adapters

10
REGO

YEAR
(CGA 510) POL WARRANTY
970 (CGA 510) POL
970S
Hard Nose POL
Soft Nose POL w/60 DMS Orifice

D
D

C B B
C
50-70
Micron
A Filter
(CGA 510) POL A
970AXS
Soft Nose POL w/Excess Flow 3199W (CGA 510) POL
Heavy Duty Hard Nose POL w/Excess Flow
3188 Series
D

C B

970AX (CGA 510) POL


Hard Nose POL w/Excess Flow 970AW 970JR
970HT Hard Nose POL w/Hose Barb Connection
Ordering Information Soft Nose POL w/Handwheel H
Part A B C D Vapor at 100 PSIG Liquid
Number Material Outlet Thread Hex Drill Overall Length Inlet (SCFH) (GPM)
970 ¼”
970S .040” orifice - -
970AS 0.188” orifice
2 ⁄ ”
15 32

970AX ⅞”
¼”
970AXS M. NPT ⅛” 404 1.10
970WXS
3199W Brass ⁄ ”
5 32 27⁄16” 575 0.95
970AW ⁄ ”
3 16
1⅜” 2 ⁄ ”
15 32
970HT .040” orifice
- -
¼”
970JR ⅞” ⁄ ”
5 32 2⅝”
Hose Barb
3188A 350 .95
½”
3188B 1⅛” ⁄ ”
9 32 2½” 700 1.9
M. NPT
3188C 1180 2.9
Note: All nipples incorporate wrench hex section.

CGA 555 Swivel Adapters

10
REGO
A

B
YEAR C
WARRANTY

Ordering Information D
Part A B C D CGA 555
Number Material Outlet Thread Hex Drill Overall Length
12982 Brass ¼” M. NPT 1⅛” ⁄ ”
3 16 1⅞”

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H13
POL Adapters

B B

10
REGO

D A C D C

YEAR
(CGA 510) POL WARRANTY
(CGA 510) POL A
Male POL x Female NPT Male POL x Male NPT and SAE Flare
Ordering Information
Part A B C D
Ordering Information Number Material Hex Diameter
Part A B C D ⅜”
Number Material F.NPT Hex Diameter 2906D 25⁄64” ⁄ ”
11 32
M. NPT
2906A ¼” 1 ⁄ ”11 32 ⅞” ⅜”
Brass ⁄ ”
9 32
2906F Brass 23⁄32” ⅞”
2906G ½” 2” 1⅛” SAE Flare
⁄ ”
9 32
½”
2906E 29⁄32”
SAE Flare
B
B

CGA 510 D
A C
(POL) CGA 510 D Female POL x Male NPT
(POL) A C

Female POL x Female NPT and Female POL

Ordering Information
Ordering Information
A B C D
Part A B C D Part Number Material Hex Diameter
Number Material Hex Diameter
5761A ¼” M.NPT ⁄ ”
3 16

H 5760A ¼” F.NPT
⁄ ”
13 32 5761B ⅜” M.NPT ⁄ ”
13 32

5760B ⅜” F.NPT 1⅝” 1⅛” Brass 1⅝” 1⅛”


5761C ½” M.NPT
5760C Brass ½” F.NPT ⁄ ”
7 16 ⁄ ”
7 16
5761D ¾” M.NPT
5760D ¾” F.NPT 1⅞” 1⅜”
⁄ ”
13 32
5760S POL (CGA 510) 2⅛” 1⅛”

1¼” B
⁄”
78

Hose
Adapter Ordering Information
For use with fuel Part A B
gases (LP-Gas, ¼” Min ⁄ ” Hex.
9 16
Number Material
5⁄8”

Acetylene). Hex.
¼” Female
15774-1 Brass ¼” M. NPT Inverted
A B Flare
A
B Female Inverted Flare
Ordering Information
x Male NPT
Part A B
Number Material D
1300 Brass 9
”-18UNF (L.H.)
16 ¼” M. NPT

C
23⁄16”
B A E

Pressure
Gauge Adapter
A
1¼”
Hex.
F
C
Ordering Information
Ordering Information Part
Part Number Material A B C D E F
Number Material A B C 1328 ⅜” SAE Male Flare ⅜” SAE Female Flare ⁄ ”
13 16 2” 1⅛”
⅜”
1494-1 Brass ½” F. NPT ¼” F. NPT ½” M. NPT 1331 Brass ½” SAE Male Flare ½” SAE Female Flare Hose 1’ 2⅛”
Barb 1¼”
1332 ⅝” SAE Male Flare ⅝” SAE Female Flare 1⅛” 2½”

H14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Copper Pigtails

Features
• Heavy duty construction.
• Individually soldered connections to the copper tubing.
• Each pigtail is individually tested prior to shipment.

Materials
Tubing.................................................................................... Copper
Connections............................................................................ Brass

913JS05A
912JS12

913PS05A

10
REGO

YEAR
WARRANTY

913PS12G

Straight Pigtails Bent Pigtails


Ordering Information Ordering Information
Part Number Part Number
¼” Tube ⅜” Tube ⅜” Tube H
⅞” Hex Approximate ⅞” Hex Short Type/Degree of
Approximate ⅞” Hex Short 1⅛” Hex Long Short Connections Length Nipple Bend
Connections Length Nipple Nipple Nipple ¼” M. NPT x M.
913JS05A
5” - 913PS05 POL 5” 90°
-
12” 912PS12 913PS12 913PS05A
M. POL x
M.POL x 20” 912PS20 912PA20 913PS20 913PS12G 270° Right Hand
M. POL 12”
M.POL 30” 912PS30 - 913PS30 913PS12H 270° Left Hand
36” 912PS36 912PA36 913PS36
48” 912PS48 912PA48 913PS48
12” 912FS12 - -
¼” Inverted 20” 912FS20 912FA20 -
Flare x M.POL 30” 912FS30 - -
36” 912FS36 - -
5” - - 913JS05
¼” M.NPT x 12” 912JS12 - 913JS12
M.POL 20” 912JS20 912JA20 913JS20
36” 912JS36 - -
½” M.NPT x
12” - - 913LS12
M.Pol
½” M.NPT x
12” - - 913KL12
⅜” M.NPT

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO
H15
H

H16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Section J
Miscellaneous Equipment
(Including Rotogage® Dials
and Emergency Shutoff Valves)
J J

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J1
Limited 10 Year Warranty and Limitation Of Liability

LIMITED 10 YEAR WARRANTY


RegO warrants to the original purchasers the products and repair NOTE: Some states do not allow the exclusion or limitation of
kits manufactured by it to be free from defects in materials and incidental, consequential or punitive damages, so the above
workmanship under normal use and service for a period of 10 years limitation or exclusion may not apply to you. The warranty gives
from the date of manufacture. If within thirty days after buyer’s you specific legal rights, and you may have other rights that
discovery of what buyer believes is a defect, buyer notifies in writing vary from State to State. The portions of this limited warranty
and ships the product to RegO at 100 RegO Drive, Elon, NC 27244, and limitation of liability shall be considered severable and all
RegO, at its option, and within forty-five days of receipt , will repair, portions which are not disallowed by applicable law shall remain
replace F.O.B. point of manufacture, or refund the purchase price of in full force and effect.
that part or product found by RegO to be defective. Failure of buyer
to give such written notice and ship the product within thirty days WARNING
shall be deemed an absolute and unconditional waiver of any and all
claims of buyer arising out of such defect. All RegO products are mechanical devices that will eventually
become inoperative due to wear, corrosion and aging of components
This warranty does not extend to any product or part that is not made of material such as rubber, etc. The environment and conditions
installed and used after installation in accordance with RegO’s of use will determine the safe service life of these products. Periodic
printed instructions, all applicable state and local regulations, and inspection and maintenance are essential to avoid serious injury and
all applicable national standards, such as those promulgated by property damage.
NFPA, DOT and ANSI. This warranty does not extend to any product
or part that has been damaged by accident, misuse, abuse, failure Many RegO products are manufactured components which are
to maintain, or neglect, nor does it extend to any product or part incorporated by others on or in other products or systems used for
which has been modified, altered, disassembled, or repaired in the storage, transport, transfer and otherwise for use of toxic, flammable
field. This warranty does not cover any cosmetic issues, such as and dangerous liquids and gases. Such substances must be
scratches, dents, marring, fading of colors or discoloration. handled by experienced and trained personnel only, using accepted
governmental and industrial safety procedures.
Except as expressly set forth above, and subject to the limitation of
liability below, RegO MAKES NO OTHER WARRANTY, EXPRESS NOTICE TO USERS OF PRODUCTS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A The Limited Warranty stated above is a factory warranty to the first
PARTICULAR PURPOSE, with respect to its products and parts, purchasers of RegO products. Since most users have purchased
whether used alone or in combination with others. RegO disclaims all these products from RegO distributors, the user must within thirty
J warranties not stated herein. (30) days after the user’s discovery of what user believes is a defect,
notify in writing and return the product to the distributor from whom
he purchased the product/part. The distributor may or may not at
LIMITATION OF LIABILITY the distributor’s option choose to submit the product/parts to RegO,
pursuant to this Limited Warranty. Failure by buyer to give such
RegO’s total liability for any and all losses and damages arising out of written notice within thirty (30) days shall be deemed an absolute and
any cause whatsoever shall in no event exceed the purchase price of unconditional waiver of buyer’s claim for such defects. Acceptance
the products or parts in respect of which such cause arises, whether of any alleged defective product/parts by RegO’s distributor for
such cause be based on theories of contract, negligence, strict replacement or repairs under the terms of RegO’s Limited Warranty
liability, tort or otherwise. in no way determines RegO’s obligations under this Limited Warranty.

RegO shall not be liable for incidental, consequential or punitive Because of a policy of continuous product improvement, RegO
damages or other losses. RegO shall not be liable for, and buyer reserves the right to change designs, materials or specifications
assumes any liability for, all personal injury and property damage without notice.
connected with the handling, transportation, possession, further
manufacture, other use or resale of products, whether used alone or
in combination with any other products or materials.

From time to time buyers might call to ask RegO for technical advice
based upon limited facts disclosed to RegO. If RegO furnishes
technical advice to buyer, whether or not at buyer’s request, with
respect to application, further manufacture or other use of the
products and parts, RegO shall not be liable for such technical advice
or any such advice provided to buyer by any third party and buyer
assumes all risks of such advice and the results thereof.

J2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Foreword

This catalog describes a complete line of equipment available from RegO® for use with Liquid Propane (LP)-
Gas and anhydrous ammonia (NH3). The following points are important to know for proper use of the catalog:

1. Illustrations and drawings of individual products are representative of “product groups” and all products
within a product group are similar in construction.

2. Materials used for construction of products in this catalog are suitable for rated service pressure at
temperatures of -40°F to +165°F, unless otherwise specified.

3. Products in this catalog are only intended for use in LP-Gas and/or anhydrous ammonia service as follows.

a.“A” or “AA” prefix — Products with this prefix are suitable for NH3 service (i.e., contain no
brass parts).

b.“AA” prefix on relief valves — These valves are NOT suitable for use with LP-Gas service.
These are of partial aluminum materials and are listed by Underwriters Laboratories (UL)
for NH3 service only.

c.All other products including “A” prefix are suitable for use with LP-Gas & NH3 service.

d.SS” prefix—Hydrostatic relief valve with this prefix are suitable for NH3 and LP-Gas service
(i.e., they have stainless steel materials).

4. We manufacture valves and adapters designed to be used on LP-Gas and Anhydrous Ammonia systems,
we do not design systems or consult in system design. For this type of information consult a professional
Engineer. J
Caution Notice
Do not use any product contained in this catalog with Installation, usage, and maintenance of all RegO products
any service commodity other than LP-Gas or NH3. If you must be in compliance with all RegO instructions as well as
have a need for use of another application, contact requirements and provisions of NFPA #54, NFPA#58, DOT,
RegO, 100 RegO Drive, Elon, NC 27244, (336) 449-7707 ANSI, and all applicable federal, state, provincial and local
ecii@regoproducts.com before proceeding. standards, codes, regulations, and laws.

Proper application, installation and maintenance of products Inspection and maintenance on a periodic basis is essential.
in this catalog are essential. Users of these products Installation and maintenance should be performed only by
should obtain further information if there are any doubts or qualified personnel.
questions.
Be sure all instructions are read and understood before
installation, operation and service.

Warning
All RegO products are mechanical devices that will
eventually become inoperative due to wear, corrosion and
aging of components made of materials such as rubber.
The environment and conditions of use will determine the Filters
safe service life of these products. Periodic inspection
and maintenance are essential to avoid serious injury and RegO LP-Gas equipment is designed to operate in a system
property damage. free from contamination. A variety of in-line filters are
commercially available to the LP-Gas industry for installation
Many RegO products are manufactured for storage, in domestic systems.
transport, transfer and use of toxic flammable and dangerous The use of an in-line filter should be considered when
liquids and gases. Such substances should be handled by other system components may be unclean and the system
experienced and trained personnel only, using accepted contaminated by rust, scale, dirt, debris or other foreign
governmental and industrial safety procedures. Never vent material.
LP-Gas near any possible source of ignition.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J3
Low Emission Unloading Adapter
A7568LE

Application
Designed for use in conjunction with our 6588LE and 6589LE low
emission filler valves installed on bobtails and transports. Valve is
designed to unload through the 6588LE and 6589LE filler valves.
stem position is controlled by the hand-wheel with a durable ACME (2.637)

thread for maximum travel with minimal rotation. Stem will open
upper check of filler valve and allow flow out of the tank.
Features (7.678)

• V-ring spring loaded pressure stem seal provides for


leak-proof operation. No packing to retighten or replace.
(Ø5.250)
• Circular bridge in globe design and a dropped seat in the
angle design achieve greater flow with less pressure drop.

• Heavy duty rolled ACME stem threads provide quick action


and long service life. (2.637)

• Cap and plug provided for safe storage when not in use
(5.250)
(7.678)
• Durable RegO adapters on inlet and outlet. (5.616)

Materials A7568LE
Body ................................................................................ Ductile Iron
Stem............................................................................Stainless
(5.250) Steel
3¼” M.ACME X 2” M.NPT Adapter..............................Stainless
(5.616) Steel
(Ø5.250)
Body........................................................................................ Brass
J Screen....................................................................... Stainless Steel (2.637)
Gasket.................................................................... Resilient Rubber

(2.637)

(7.678)

10
(4.866)

REGO (8.082)

(5.250)

YEAR (2.637)

WARRANTY

(5.250)

(5.616)

(4.866)
Ordering Information (8.082)

(5.250)

Part Number Inlet Outlet Cap and Plug for Both Ends

A7568LE 3¼” F. ACME 3¼” M. ACME Yes


(2.637)

J4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
LP-Gas Fueling Nozzle
FN Series

Application

18
Designed for LP-Gas fueling stations, the FN Series LP-Gas fueling REGO
nozzle provides a fast flow rate and low emission on disconnect. The
FN Series fueling nozzle only allows gas to flow when it is correctly
coupled, no opening is possible when misaligned.
MONTH
WARRANTY
Features
• Meets 2020 NFPA 58 guidelines
• Quick, safe and reliable
• Light weight and easy to use
• Less emissions when compared to ACME connector
• Nearly identical refueling experience to gasoline or diesel
• Flow rate: up to 13 gpm
• Low maintenance = low running cost
• Safety hold-open latch
FN1001
• Both latched and unlatched versions are UL Standard
FN1356
• Fully repairable
• 18 Month manufacturer’s warranty
• One hand operation
• ¾” NPT hose connection
• Can be used with propane, butane and mixtures
• Only allows gas flow when correctly coupled

FN1000

FN1357
4”
4.8

1.
97

Underwriters Laboratory listed,


file reference No. MH17142, Vol.
Meets EN13760/UN R67 / ISO 19825
FUELING NOZZLE Designed, tested and marks in
FN1356 SERIES accordance with ATEX.

Accessories
Part Number Flow Rate Talker Nozzle Holster Talker
Locking Non-Locking Black Orange
FN1355 Not Included
FN1356 13 GPM Black FN1001 FN1000 FN1300 FN3101
FN1357 Orange

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J5
Grounding Stud
7172 and 7173

Application

10
Designed to help prevent static electricity from being generated REGO
during the filling process. Used in conjunction with a grounding
clamp assembly at a bulk tank facility.
YEAR
WARRANTY

Features
• 625” Rounded Ball stud
• ⅜” or ½” Threads available
• Washer and nut included

Materials
Stud........................................................................................... Brass
Washer........................................................................Stainless Steel
Nut...............................................................................Stainless Steel
7171

SØ.625

J (.750 HEX) (1.229)

GROUNDING LUG
7171 SERIES

Part Number Thread “L”


7172 ⅜”
1.063
7173 ½”

J6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
1” Rotogage® Dial for Large Mobile and Stationary Containers
A9090 Series

Application
Rotogage® dials are designed to provide an accurate determination
of LP-Gas or anhydrous ammonia container contents. They mount in
a standard 1” NPT coupling on large mobile or stationary containers.

To operate the Rotogage® dials, the vent valve is opened and the
dip tube rotated slowly from the container vapor space to the liquid
space. The difference in appearance of the discharge indicates when
the liquid level is reached. Dial readings then indicate the percentage
of product in the container.

Features
• Supported design (TS Models) eliminates whipping and the need
for internal support hangers.

• Resistance-free nylon bearing inserts reduce friction and promote


operating ease.

• Dial face is dual calibrated to provide greater accuracy in reading


contents in containers which are not level.
Rotogage® Dial
• Interchangeable accessory dials permit interchangeable service
between LP-Gas and anhydrous ammonia.

Materials
Body......................................................................................... Steel
Stem......................................................................................... Steel J
Dip Tube................................................................... Seamless Steel
Indicator...................................................................... Malleable Iron
Dial Plate.......................................................................... Aluminium
Vent Stem.................................................................. Stainless Steel

Tubes for use with A9090 Series Rotogage® Dial


Cut to length required.

Service Part Number


Up to 48” A9091-M24.0
Up to 72” A9091-M36.0
Up to 96” A9091-M48.0
Up to 120” A9091-M60.0
Up to 144” A9091-M72.0

10
REGO

YEAR A9091-18LX
WARRANTY

Rotogage® Dials
Ordering Information
Part Number Service Container Size
A9091-18L LP-Gas All Sizes
A9091-18LX* LP-Gas Over 1200 U.S. gallons
A9091-18N NH3 All Sizes
* Dial permits higher filling level, per NFPA 58,

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J7
1” Rotogage® Dials for Large Mobile and Stationary Containers

For Small Mobile or Stationary Containers


A9091R and A9092R Series

For Large Stationary Containers


9093RS, 9094RS and 9095RS Series

For Large Mobile or Stationary Containers


A9093TS, A9094TS and A9095TS Series

10
REGO

YEAR
WARRANTY

Ordering Information
For Container Inside Diameter

Part Number Ellipsoidal Heads Hemispherical Heads


For Stationary Side End Side End
For Mobile or Stationary Containers Containers Only Mounted Mounted Mounted Mounted
A9091R - 30” - 45” 30” - 75” 30” - 45” 30” - 45”
A9092R - 46” - 61” 76” - 108” 46” - 61” 46” - 61”
A9093TS* A9093RS 62” - 79” 109” - 147” 62” - 79” 62” - 79”
A9094TS* A9094RS 80” - 99” - 80” - 99” 80” - 99”
A9095TS* A9095RS 100” - 147” - 100” - 147” 100” - 147”
* Supported Design
NOTE: The dip tube must be cut to the required length(½” of container inside diameter minus 5¾”).

J8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
¾” Rotogag® Assemblies for Small Stationary and Mobile LP-Gas Containers
2070 Series

Application
Rotogage® dials are designed to provide accurate determination
of LP-Gas container contents. They may be end or side mounted
in a standard ¾” NPT coupling on stationary or mobile containers.
To guarantee accurate measurement, they should not be used on
stationary containers that exceed 60” I.D. or on mobile containers,
subject to vibration, with an I.D. of more than 24”.

Features
• Provides long, trouble-free performance and ease of operation.

• Polished stems ensure bind-proof operation.

• Dial face is dual calibrated to provide greater accuracy in reading


contents in containers which are not level.

2070 Series

Materials
Body........................................................................................ Brass
Stem............................................................................. Brass Tubing
Dip Tube...................................................... Seamless Brass Tubing
Dial Plate.......................................................................... Aluminium
Indicator...................................................................... Malleable Iron

10
REGO - 1.65”
1.41”

YEAR
WARRANTY

Ordering Information
Part Number
For Containers with Inside
Rotogage® Dial Dip Tube Diameter Tank Connection Valve Seat Orifice
2071-L25.7 Up to 40” No. 54
2070C0 ¾ M. NPT
2071-L39.7 Up to 60” Drill Size
NOTE: The dip tube must be cut to the required length (½ of container inside diameter minus
½”), when mounted on center line of tank.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J9
Pull-Away Valves for Transfer Operations
A2141 Series

Application
Designed especially to provide pull-away protection for LP-Gas and
anhydrous ammonia transfer operations including transport and
delivery truck loading and unloading, engine fuel container filling and
miscellaneous cylinder filling operations. When properly fastened to
the inlet end of the discharge hose, the valve is designed to stop gas
escape from both upstream and downstream lines in the event of a
pull-away. An excessive tension pull causes the valve to automatically
separate, closing two internal back pressure checks. Only a few cubic
centimeters of gas escape at the instant of separation.
A2141A6
It is recommended that a convenient means be provided to safely
remove the pressure from the line upstream of each coupling half to
enable reassembly of the valve. To reassemble, simply push the male
half firmly into the female half until the retaining balls slip into the
retaining groove. Check for leaks after reassembly.

NOTE: It is recommended that pull-away valves be maintained and


safety tested perodically to confirm that they will separate properly in
the event of a pull-away. Lubrication every six months is essential to
the pull-away’s operation. Dry nitrogen or other inert gas is suggested
as a source of pressure for pull-away tests.

If the A2141 pull-away valve is going to be stored for a period of time,


A2141 Series such as in seasonal applications, it is recommended
that it be sprayed with a good grade of rust-preventive machine oil, A2141A10
and covered to protect it from moisture.

Features
• Heavy-duty construction for long service life.
• A “true’’ pull-away type valve which simply reconnects by snapping
J •
together without unnecessary downtime or need for new parts.
Buna-N seals provide leak tight operation.
• 400 PSIG operating pressure.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Materials
Body (¾”, 1”)................................................. Cadmium Plated Steel
Body (1¼”, 2”)............................................... Cadmium Plated Steel
Seals........................................................................ Buna-N Rubber
Cables............................................ Nylon Coated, Galvanized Steel

8.5” Approx 12.3” 5” 5.51”

10
REGO

YEAR
WARRANTY

Ordering Information
Inlet/Outlet Disconnect Reconnect LP-Gas Liquid Flow Capacity at Various Differential Pressures (GPM)*
Part Number Connections Force Force Length A Length B
NPT F. Approx-lbs Approx-lbs 5 PSIG 10 PSIG 25 PSIG 50 PSIG

A2141A6 ⁄”
58

¾” 130 80 37⁄8” 11 16 25 36
A2141A6L** ⅛”
A2141A8 115⁄16”
1” 75 50 49⁄16” 21 30 47 67
A2141A8L** 57⁄8”
A2141A10 1¼” 160 25 5” 55⁄8” 52 75 120 170
A2141A16 2” 300 50 8½” 14 ⁄ ”
5 16 250 350 550 750
* To Determine NH liquid flow capacity, multiply by .90.
3

J10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
LP-Gas Emergency Shut-Off Valves (ESV’s)

Why and how they should be used for Bobtail Filling Section 5.14.2.5 states where fusible elements are used; the
and Transport Unloading. melting point cannot exceed 250°F (121°C).

General Information This provision sets for the basic criteria for the emergency
The primary purpose of Emergency Shut-Off Valves in bobtail filling shutoff valve, a key valve in the protection of many liquid transfer
operations. Actuating means for remote control may be electrical,
and transport unloading is to allow quick shut-off of liquid and vapor mechanical or pneumatic.
flow in the event there is an accidental pull-away of a truck or a hose
rupture, both of which could cause a fire. Many systems use a pneumatic system where the tubing itself
acts as a fusible element releasing the pressure holding the
A system using Emergency Shut-Off Valves will not prevent valve open. With respect to the feature of manual shutoff at the
some spillage of liquid and vapor, but the total system should be installed location, it is recommended that this valve be operated
constructed so this spillage will be kept to a minimum. occasionally. Also, the system should be tested periodically to
determine that it will function properly.
This can be accomplished either by making possible, quick action
by the driver or plant personnel in closing the valves by manual Section 6.14.1 covers new and existing installations, stationary
remote or pneumatic remote actuation; or in case of a pull-away, by container storage systems with an aggregate water capacity of
automatic closing of the liquid valve by means of a cable connected more than 4000 gal (15.1m³) utilizing a liquid transfer line that is
1½ in. (39 mm) or larger and pressure equalizing lines 1¼ in (32
to the liquid hose. mm) or larger, must be equipped with emergency shutoff valves.
By minimizing the presence of liquid and vapor, the chance of a fire or Section 6.14.2 describes where an emergency shutoff valve must
explosion will be reduced. In case of a fire, thermal links at the valves be installed in the transfer lines of the fixed piping transfer system
or at other appropriate locations could close the valves and prevent within 20 ft (6m) of lineal pipe from the nearest end of the hose or
further release of liquid and vapor. swivel-type piping connections.
Section 6.14.5 covers installations where there are two or more
The valve closing systems will be discussed later in this section. The liquid or vapor lines with hoses or swivel-type piping connected
user should decide which system is most appropriate, depending on of the sizes designated in 6.12.1, an emergency shutoff valve or
the piping configuration and the general layout of the filling/unloading a backflow check valve, where allowed, must be installed in each
area. leg of the piping.

ESV Application for Bobtail Loading and Transport Unloading Section 6.14.6 states the requirements for thermal protection;
emergency shutoff valves must be installed so that the
temperature-sensitive element in the valve, or a supplemental
A very important function of the typical LP-Gas storage plant is to temperature-sensitive element that operates at a maximum
transfer LP-Gas into bobtails for delivery to customers. How efficiently temperature or 250°F (121°C) that is connected to actuate the
and rapidly these bobtails can be filled often determines the number valve. It also states maximum distance this can be which is not
of customers that can be served each day, as well as how many more than 5ft (1.5m) from the nearest end of the hose or swivel-
bobtails are required to satisfactorily serve all customers. Therefore, type piping connected to the line in which the valve is installed. J
the selection of an ESV for the bobtail liquid loading line should be
done with care so as to maximize efficiency in filling and have year- Section 6.14.7 requires that the temperature-sensitive elements of
emergency shutoff valves cannot be painted, or can they have any
round dependability. ornamental finishes applied after manufacture.
The RegO 2” (A6016) and 3” (A6024) liquid ESVs have a full open Section 6.14.8 emergency shutoff valves or backflow check valves
port so that the restrictions of flow would be no more than you would must be installed in the fixed piping in manner to protect them
expect through an equivalent length of schedule 80 pipe. To improve so that any breaks resulting from a pull will occur on the hose or
the overall efficiency of the system, the valves were designed as an swivel-type piping side of the connection; allowing the valves and
operating valve so it could replace an existing globe or angle valve piping on the plant side of the connection to remain intact.
already installed at the end of the fixed piping. Thus, installing a Section 6.14.9 emergency shutoff valves that are required to
RegO ESV could actually result in a more efficient pumping operation be installed in accordance with 6.14.2, that a means must be
than the existing system. incorporated to actuate the emergency shutoff valves in the event
of a break of the fixed piping resulting from pulling of the hose.
Equally important in the consideration of an ESV is its performance
in an emergency, especially bobtail pull-aways. Therefore, when Section 6.14.10 states that all emergency shutoff valves required
selecting the proper ESV for bobtail filling, also consider the by the code be annually tested for the functions required in 5.14.2.3
(2) Manual shutoff from a remote location, (3) Manual shutoff at the
dependability of performance, and simplicity of operation and installed location; the results of the test are documented.
maintenance.
Section 6.14.12 requires that new and existing emergency shutoff
The RegO ESVs clearly indicate to the operator its open or closed valves shall comply with 6.14.12.1 through 6.14.12.3 below.
position. It allows full manual control by the operator and provides
means for remote operation in emergencies from either in front of the Section 6.14.12.1 requires that the emergency shutoff valve shall
valve or in the rear. have at least one clearly identified and accessible manually
operated remote shutoff device.
No complicated systems of pulleys and cables are necessary since Section 6.14.12.2 states that the remote shutoff device for an
direct, straight pulls will close the valve. Means are even provided emergency shutoff valve must be located not less than 25ft (7.6m)
to secure a length of cable to the transfer hose so as to produce or more than 100 ft. (30 m) in the path away from the emergency
an automatic closing in the event the driver pulls away without shutoff valve.
disconnecting the hose.
Section 6.14.12.3 describes the requirements when an emergency
shutoff valve is used in place of an internal valve in compliance
NFPA Provisions (2020) with 5.9.4.2(D) (2) the remote shutoff device have to be installed in
accordance with 6.13.4 and 6.13.5.
The pertinent provisions of NFPA Pamphlet 58, as they apply to
Emergency Shut-Off Valves and how they are to be installed are
below (for complete information refer to NFPA 58):.
The provisions above and others covered in NFPA 58 can assist
Section 5.14.2.3 requires that emergency shutoff valves be in determining how bobtail filling and transport unloading stations
approved and incorporate all the following means of closing: (1) are to be configured. The diagrams shown here offer general
Automatic shutoff through thermal (fire) actuation, (2) Manual shutoff information, they should not be used as an installation guide.
from a remote location, (3) Manual shutoff at the installed location.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J11
LP-Gas Emergency Shut-Off Valves (ESV’s)

Installation Compliance with NFPA Requirements


vapor system is this: If the vapor flow is out of the storage tank, an
A valve that is approved as an ESV may be installed in the fixed ESV is required. ESV systems are designed to protect the storage
piping up to a distance of 20 feet (along the pipe) from the point tank contents against uncontrolled release.
where the transfer hose is attached to the fixed piping.
Therefore, a bobtail loading system could use a 1¼” or larger back
However, when the ESV is located more than five feet from the end of pressure check valve in the vapor system since the flow of vapor
the fixed piping, an additional fusible element must be installed within is always from the bobtail being filled back to the storage tank. To
five feet of the point of attachment of the hose, and be connected to improve transfer rates, the use of the RegO 6586D back check valve
the ESV valve in such a manner that it will cause the ESV to close in at this location would provide protection at minimum pressure drop.
the event of a fire.
J The ideal location of the ESV is as close to the end of the fixed
If the bobtail vapor line is also used when unloading transports, then
the RegO A6010 ESV should be used. The A6010 provides thermal
piping as possible. This position eliminates the need for an additional protection, manual closing and a remote emergency closing system
fusible element and cable, and it may also permit the elimination of a similar to the RegO 2” liquid ESV, A6016.
restrictive valve already installed at the end of the fixed piping.
Remote Control Systems
To this point, our comments have been principally concerned with
ESV protection of the liquid line at bulk plants because this is the Usually in transfer loading operations, the valve handles and cables
area of greatest potential danger in the event of a pull-away or hose are located in close proximity to the area of greatest potential danger
rupture. during an emergency. Therefore, each bobtail filling system or
transport unloading system should have installed in it at least one
However, regulations also require an ESV in the vapor transfer line readily accessible, alternate remote operating device.
when the vapor hose is 1¼” or larger. A helpful rule of thumb in
determining whether or not an ESV control valve is required in your

A6010, A6016, A6024 ESVs

Figure 2
RegO ESV’s with Remote Pneumatic
and Transfer Hose Cable Release
Systems Typical Installation

J12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
2” & 3” Swing-Check ESVs for Bulk Plants
A6016 Series and A6024 Series

Application
Designed for installation in liquid transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.

Features
• Fusible Element is located in the thermal fuse assembly which
acts at the latch open and close trigger. When exposed to fire,
the element melts at 212° F allowing the shaft to return to the
closed position. A6016
• Valve can be opened by use of operating lever, if a pneumatic
actuator is used it will open with the actuator.
• Valve can be closed by remote cable or pneumatic actuator.
• Valve can be closed by simply pushing the operating lever down,
it is not necessary to trip the close trigger. 4.82”
• Seat Disc is retained by a metal seat to minimize leakage in case
8.09”
of direct fire impingement.
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Quick closing regardless if the pump is running or not.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Sturdy Rugged Construction

• Will withstand hydraulic shock of sudden closings, piping strains,


and temperature variations. 7.26”
10.44”
• Valve has only two moving parts, stem and close/thermal trigger.
J
• A6016 is UL listed for use in LP-Gas as an emergency and
operating shut-off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.

5.69”
Materials 9.55”
Body............................................................. Ductile Iron Cad Plated
Stem.......................................................................... Stainless Steel A6024
Seat........................................................................... Stainless Steel
Seat Disc (VA6016/VA6024)........................ High Temperature Viton
Seat Disc (A6016/A6024).......................................................... Nitrite
Springs...................................................................... Stainless Steel
Gaskets................................................................................... Teflon
7.5”

10
REGO

5.5”
YEAR 9.55”
WARRANTY
9.9”
11.17”
Ordering Information
Accessories
Inlet and
Outlet Liquid Flow Capacity at Remote Open/Close Remote Open/Close
Part Number Seat Connections 10 PSIG Drop (GPM) Remote Close Pneumatic Pneumatic Rotary Electric Actuator
VA6016 Viton 2” F.NPT 711 (LP-Gas)
A6016 Buna-N 2” F.NPT 640 (NH3 or LP-Gas)
6016--60D 6016-60C 6016RA 6016EA
VA6024 Viton 3” F.NPT 1325 (LP-Gas)
A6024 Buna-N 3” F.NPT 1173 (NH3 or LP-Gas)

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J13
1¼” Swing-Check ESV for Bulk Plants
VA6010 and A6010

Application
Designed for installation in liquid or vapor transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.

Features
Meets NFPA 58 and UL requirements

• Fusible Element is located in the thermal fuse assembly, which


acts at the latch open and close trigger. When exposed to fire, the
element melts at 212 degrees F. allowing the shaft to return to the
closed position. 6010
• Valve can be opened by use of operating lever. If a pneumatic
actuator is used it will open with the actuator. A6010
• Valve can be closed by remote cable or pneumatic actuator.
• Cannot trap liquid between the outlet of the valve and a shutoff 9.9

valve downstream (no hydrostatic relief valve required; swing


check will open and allow backflow at minimal differential
pressure).
• Valve can be closed by simply pushing the operating lever down;
it is not necessary to trip the close trigger.
• Temperature range of -40°F to +165°F (-40°C to +73°C) 3.4

• MAWP: 400 PSIG(27 Bar)


5.2

Sturdy Rugged Construction


• Will withstand hydraulic shock of sudden closings, piping strains,
and temperature variations.

• Valve has only two moving parts, stem and close/thermal trigger.
9.9 5.7

J • A6010 is UL listed for use in LP-Gas as an emergency and


operating shut-off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.
3.4
• Seat Disc is retained by a metal seat to minimize leakage in case
of direct fire impingement. 5.2

• Quick closing regardless if the pump is running or not.

Materials
Body............................................................ Ductile Iron Clad Plated
Stem.......................................................................... Stainless Steel
Seat........................................................................... Stainless Steel
6016-60D
Seat Disc.................................. High Temperature Viton (6010 only)
Seat Disc....................................... Synthetic Rubber (AA6010 only)
Springs...................................................................... Stainless Steel
Gaskets................................................................................... Teflon

10
REGO

YEAR
WARRANTY

6016RA 6016-60C
Ordering Information
Accessories Liquid Flow Capacity
Part Inlet and Outlet @ 10 PSIG Pressure Drop
Seat Remote Remote Pneumatic Rotary Actuator Electric Actuator
Number Connections (GPM)
Pneumatic Close Open/Close
VA6010 Viton 1¼” F. NPT 259 (LP-Gas)
6016-60D 6016-60C 6016RA 6016EA
A6010 Buna-N 1¼” F. NPT 233 (NH3 or LP-Gas)

J14 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
¾” & 1” Swing-Check Emergency Shutoff Valves (ESV) For Small Pipe Installations
A6006 & A6008 Series

Application
The A6006 & A6008 series are designed for installation in liquid
transfer lines at LP-Gas fueling stations or other small pipe
installations. These valves provide for quick shut-off of flow in the
event of an accidental line break or hose rupture. These ESVs
also utilize a thermal fuse assembly that will shut-off flow in case
of fire.

Features & Benefits


• Meets NFPA 58 and UL requirements
• Fusible element is located in the thermal fuse assembly, which
acts at the latch open and close trigger. When exposed to fire, the
element melts at 212° F, (100° C,) allowing the shaft to return to
the closed position. A6008
• Valve can be closed by remote cable or pneumatic actuator.
• Valve can be closed by simply pushing the operating lever down;
it is not necessary to trip the close trigger.
• Sturdy Rugged Construction
• Will withstand hydraulic shock of sudden closings, piping strains,
and temperature variations.
• Valve has only two moving parts: stem and close/thermal trigger.
• A6006 and A6008 are UL listed for use in LP-Gas and NH3 as an
emergency and operating shut-off valve.
• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.
• Seat Disc is retained by a metal seat to minimize leakage in case
of direct fire impingement. A6000-60D
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• Quick closing regardless if the pump is running or not.


Temperature range of -40°F to +165°F (-40°C to +73°C)
MAWP: 400 PSIG(27 Bar) (2.364)
J
(2.145)

(1.305)

(4.312)
(3.494)
(4.879)
(5.004)
(R6.725)
Materials
Body...............................................................Ductile Iron Cad Plated
Stem............................................................................Stainless Steel
Seat Disc................................................................................... Nitrile
Springs...................................................................... Stainless Steel
Packing......................................................................................Teflon (2.364)
(2.145)

10
REGO

(1.305)

YEAR
(4.312)
WARRANTY (3.494) (7.446)
(4.879)
(5.004)
Ordering Information
Accessories Liquid Flow Capacity @
Inlet and Outlet
Part Number Seat 10 PSIG
Connections Remote Pneumatic Close
(2.041)
Cable Release Close Pressure Drop (GPM)

54 (LP-Gas)
A6006 ¾" F. NPT 49 (NH3)
Nitrile A6000-60D* A6000TFA**
120 (LP-Gas)
A6008 1" F. NPT 108 (NH3)
*Must be ordered separately
**Equipped standard on valve assembly

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J15
Flanged ESVs for Bulk Plants
FA6010, FA6016 and FA6024

Application
Designed for installation in liquid transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid 5.99”
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.
3.91” 10.87”
Features 6.54” 12.13”
• Fusible Element is located in the thermal fuse assembly which
acts at the latch open and close trigger. When exposed to fire, the
element melts at 212° F allowing the shaft to return to the closed
position. FA6010
• Valve can be opened by use of operating lever, if a pneumatic
actuator is used it will open with the actuator.
• Valve can be closed by remote cable or pneumatic actuator.
• Valve can be closed by simply pushing the operating lever down. 5.99”
It is not necessary to trip the close trigger.
• Seat Disc is retained by a metal seat to minimize leakage in case
of direct fire impingement.
• Cannot trap liquid between the outlet of the valve and a shutoff 3.91” 10.87”
6.54” FA6016
valve downstream (no hydrostatic relief valve required; swing 12.13”
check will open and allow backflow at minimal differential
pressure).
• Quick closing regardless if the pump is running or not.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) 6.63”

Sturdy Rugged Construction

• Will withstand hydraulic shock of sudden closings, piping strains, 5.13” 11.91”
6.63” 8.38” 13.62”
and temperature variations.

• Valve has only two moving parts, stem and close/thermal trigger.
5.13” 11.91”
J • UL listed for use in LP-Gas as an emergency and operating shut- 8.38” 13.62”
off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.

Materials
Body............................................................. Ductile Iron Cad Plated
Stem.......................................................................... Stainless Steel
Seat........................................................................... Stainless Steel
Seat Disc (FVA6010/16/24)......................... High Temperature Viton
Seat Disc (FA6010/16/24)......................................................... Nitrile FA6024
Springs...................................................................... Stainless Steel
Stem Seals.............................................................................. Teflon

10
REGO

8.23”

YEAR
WARRANTY 5.81” 13.46
9.93” 14.13”

Ordering Information
Accessories
Liquid Flow Capacity Remote Close Remote Open/ Remote Open/Close
Part Number Seat Inlet and Outlet Connections at 10 PSIG Drop (GPM) Pneumatic Close Pneumatic Rotary Electric Actuator
FVA6010 Viton 1¼” - 300# ANSI RF Flange 233 (NH3)
*
FA6010 Buna-N 1¼” - 300# ANSI RF Flange 259 (LP-Gas)
FVA6016 Viton 2” - 300# ANSI RF Flange 640 (NH3) FA6016-
6016RA 6016EA
FA6016 Buna-N 2” - 300# ANSI RF Flange 711 (LP-Gas) 60D
6016-60C
FVA6024 Viton 3” - 300# ANSI RF Flange 1173 (NH3)
FA6024 Buna-N 3” - 300# ANSI RF Flange 1325 (LP-Gas)
* Not Available

J16 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Swing-Check ESVs for Bulk Plants with Electric Actuator
EA6010, EA6016 and EA 6024

Application
Designed for installation in liquid transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.

Features
• Fusible Element is located in the thermal fuse assembly which
acts at the latch open and close trigger. When exposed to fire, the
element melts at 212 degrees F. allowing the shaft to return to the
closed position.
• The EA6010, EA6016 and EA6024 provide a convenient means of
electrically opening and closing the valve from a remote location.
• Seat Disc is retained by a metal seat to minimize leakage in case
of direct fire impingement.
• Quick closing regardless if the pump is running or not.
• CSA/UL rated Explosion Proof Enclosure on the actuator.
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• ESVs and Electric Actuators are UL Listed
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Sturdy Rugged Construction

• Will withstand hydraulic shock of sudden closings, piping strains,


and temperature variations.

• Valve has only two moving parts, stem and close/thermal trigger.
J
• EA6016 is UL listed for use in LP-Gas as an emergency and
operating shut-off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.

Materials
Body............................................................. Ductile Iron Cad Plated
Stem.......................................................................... Stainless Steel
Seat........................................................................... Stainless Steel
Seat Disc (EA6010/16/24)......................................................... Nitrile
Springs...................................................................... Stainless Steel
Stem Seals.............................................................................. Teflon

10
REGO

YEAR
WARRANTY

Ordering Information
Liquid Flow Capacity at 10 PSIG Drop
(GPM)
Inlet and Outlet
Part Number Seat* Connections Voltages LP-Gas NH3
EA6010 1¼” F.NPT 259 233
EA6016 Buna-N 2” F.NPT 12/24 VDC 711 640
EA6024 3” F.NPT 1325 1173
* Viton seat available on request.

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J17
Flanged ESVs for Bulk Plants with Electric Actuator
EFA6010, EFA6016 and EFA6024

Application
Designed for installation in liquid transfer lines at LP-Gas or
Anhydrous Ammonia bulk plants to provide for quick shut-off of liquid
or vapor flow in the event of an accidental pull-away, line break, or
hose rupture.

Features
• Fusible Element is located in the thermal fuse assembly which
acts at the latch open and close trigger. When exposed to fire, the
element melts at 212° F allowing the shaft to return to the closed
position.
• The EFA6010, EFA6016 and EFA6024 provide a convenient
means of electrically opening and closing the valve from a remote
location.
• Seat Disc is retained by a metal seat to minimize leakage in case
of direct fire impingement.
• Quick closing regardless if the pump is running or not.
• CSA/UL rated Explosion Proof Enclosure on the actuator.
• Class I, Div 1 Groups B, C, D, / T6
• 12-24VDC
• Cannot trap liquid between the outlet of the valve and a shutoff
valve downstream (no hydrostatic relief valve required; swing
check will open and allow backflow at minimal differential
pressure).
• ESVs and Electric Actuators are UL Listed
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

Sturdy Rugged Construction

• Will withstand hydraulic shock of sudden closings, piping strains,


and temperature variations.

J • Valve has only two moving parts, stem and close/thermal trigger.

• UL listed for use in LP-Gas as an emergency and operating shut-


off valve.

• Stem seals are spring loaded for leak free performance at low
temperatures/pressures.

Materials
Body............................................................. Ductile Iron Cad Plated
Stem.......................................................................... Stainless Steel
Seat........................................................................... Stainless Steel
Seat Disc (EA6010/16/24)......................................................... Nitrile
Springs...................................................................... Stainless Steel
Stem Seals.............................................................................. Teflon

10
REGO

YEAR
WARRANTY

Ordering Information
Liquid Flow Capacity at 10 PSIG Drop (GPM)
Part Number Seat* Inlet and Outlet Connections Voltages LP-Gas NH3
EFA6010 1¼” - 300# ANSI RF Flange 259 233
EFA6016 Buna-N 2” - 300# ANSI RF Flange 12/24 VDC 711 640
EFA6024 3” - 300# ANSI RF Flange 1325 1173
* Viton seat available on request.

J18 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
ESV Pneumatic Controls

Application
RegO Emergency Shut-Off Valves modified for remote pneumatic
shutdown operation retain all the operating features of the standard
valves.

Once equipped with pneumatic cylinders and then pressurized,


the pneumatic cylinder piston rod disengages from a striker plate,
allowing the ESV to be manually opened and the striker plate to act
as a latch and hold the valve open. Release of the control system
pressure for any reason closes the ESV for fail-safe operation.

Features
Convenience

• Closes the liquid and vapor ESV from a convenient remote


location. A6016 with 6016-60D Remote Close Actuator

• Independent closed loop system allows the ESV to be


pneumatically charged, but opened or closed manually or with
cable controls to conserve pressurized gas.

Reliability

• Independent closed loop system will continue to hold pressure


and close ESV in an emergency - even if supply pressure is cut
off.

Security

• Any loss of pressure from the control line, such as accidents or


the line melting from fire, automatically shuts down the liquid and
vapor ESV.

• ESV must be reset after automatic shutdown.


J

A3219TF25 A3219TF

10
6016PN-50 Pneumatic Remote Control Kit
REGO
Control kit with components for connecting and charging the
pneumatic controls from a source of compressed gas (air or nitrogen)
to a RegO liquid or vapor ESV. Includes charging valves with low
YEAR
pressure indicator, operating valves, 100 feet of ¼” plastic tubing and
WARRANTY tube fittings.

Ordering Information
Part Number Description
6016-60D Cylinder assembly kit to convert 6016 ESVs to pneumatic shutdown.
6016PN-50 Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly
6016PN-80 Bypass kit for pneumatic actuators.
7605A-BT 100’ roll of ¼” pneumatic tubing.
7605AP-16 ¼” tubing tee, with nuts.
7605AP-15 ⅛” NPT x ¼” tubing, straight connector.
6016RM Remote Close Cable Kit
A3219TF ⅜” F. NPT 212°F Thermal Fuse Plug
A3219TF25 ¼” F. NPT 212°F Thermal Fuse Plug

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J19
Hydraulic Automatic Cylinder Filling System
7194MD and 7194HD

Application
Designed to provide accurate, economical filling of LP-Gas, DOT and
fork lift cylinders by weight. Filling stops automatically as the total
weight of the cylinder reaches the amount pre-set on the scale. One
individual can efficiently handle up to four cylinder filling operations
simultaneously to maximize profits, increase efficiency and allow
servicing of more customers.

The RegO automatic cylinder filling system is designed for use with Hydraulic self-contained system.
these scales only: No external power required.

FAIRBANKS-MORSE SCALES
New Style - 1280A Double Beam Scale or Single Beam Scales 1124A
and 1174A. Shut-off Valve
Old Style - 1280 Double Beam Scale or Single Beam Scale 1123 with
or without Howe No. 12108 “Over or Under’’ Indicator. 1

LP-Gas Supply
HOWE SCALES 6 Strainer Hydrostatic Relief Valve
(with or without Howe No. 8325 Balance Indicator)
—No. 54X Wood Pillar and Shelf Scale. 3
—No. 57 Steel Pillar and Shelf Scale (single beam).
—No. 57X Steel Pillar and Shelf Scale (double beam). 7

Open
Features 8
• Completely self-contained with no electrical source or wiring
required.
• Works hydraulically, like brakes on a car.
• Filling stops automatically when cylinders reach pre-set weight.
• Up to four stations can be handled by one individual. 2

J How It Works 4 A,B


The scale beam weight is adjusted to the desired filled weight and the Closed
empty cylinder is placed on the scale. The loading hose is connected
to the cylinder valve, and the lever on the master cylinder is moved
to the vertical position. When the quick-acting valve on the loading
hose is opened, the cylinder will rapidly fill. The master cylinder lever
is designed to trip, move to a horizontal position and automatically

10
shut off the control valve as soon as the scale reaches the pre-set REGO
filled weight.

Components may be ordered separately with piping done by the


installer. Two completely assembled manifold configurations are also YEAR
available. WARRANTY

Ordering Information Hydraulic System Components

Key
No. Description Size Part No.
Assembly for Fairbanks-Morse. Includes items 1 thru 8 below. 7194MD
Assembly for Howe. Includes items 1 thru 8 7194HD
1 Propane Control Valve ½” NPT Female, with ⅛” NPT Female Hydraulic Connection 7177
2 Master Cylinder, with Actuator Lever ⅛” NPT Hydraulic Connection 7188
3 Hydraulic Hose Assembly ⁄ ” I.D. with ⅛” NPT Male Ends, 43½” Overall Length
3 16 7194-1
1-3 Valve, Cylinder and Hose Assembly for Fairbanks-Morse Scales - 7188MS

1-3 Valve, Cylinder and Hose Assembly for Howe Scales - 7188HS

Bracket Kit for Fairbanks Morse Scales, Complete with Screws, Washers, Nuts
4A - 7194M-3A
and Instructions
Bracket Kit for Howe Scales, Complete with Screws, Washers, Nuts and
4B - 7194H-3
Instructions
5 Can of Hydraulic Fluid, Complete with Filling Spout 1½ ounce 7188-21
6 Propane Filling Hose Assembly ½” I.D., with ½” NPT Male Ends. 50½” Overall Length 7193D
7 Quick-acting Shut Off Valve ½” NPT Inlet X ¼” NPT Outlet 7901TB
8* Soft Nose Cylinder Connector ¼” NPT Male X POL Male 7193D-10L

J20 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
3” Heavy Duty Swing Check with Flow Indicator A7624

Application
This back check valve is designed to provide required back flow
protection for the unloading riser in the bulk plant’s transfer area.
It is designed specifically for pipeline installation and is suitable for
LP-Gas and anhydrous ammonia service. Product flow moves the
swing check to the open position, when flow stops the spring loaded
swing check closes.

Features
• Easy-to-read flow indicator

10
• Heavy duty spring loaded swing check design REGO
• Resilient synthetic rubber seat disc
• High flow rates with low pressure drop A7624
• May be installed either horizontally or vertically
• ¼” F.NPT plugged boss on top of body
YEAR
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) WARRANTY

Materials Outlet
7.5” Inlet
Body ................................................................................ Ductile Iron
Stem............................................................................Stainless Steel
Seat.............................................................................Stainless Steel
Seat Disc.................................................... Resilient synthetic rubber
Return Spring..............................................................Stainless Steel

Flow Direction

Ordering Information 9.9”

Part Number For Use With: Inlet & Outlet Connections Liquid Capacity at 10 PSIG Drop GPM

A7624 LPG & NH3 3” F.NPT 1325-GPM(LPG) 1173-GPM(NH3)


J
2” Heavy Duty Swing Check with Flow Indicator A7616
Application
This back check valve is designed to provide required back flow
protection for the unloading riser in the bulk plant’s transfer area.
It is designed specifically for pipeline installation and is suitable for
LP-Gas and anhydrous ammonia service. Product flow moves the
swing check to the open position, when flow stops the spring loaded
swing check closes.

Features

10
• Easy-to-read flow indicator REGO
• Heavy duty spring loaded swing check design
• Resilient synthetic rubber seat disc A7616
• High flow rates with low pressure drop
• May be installed either horizontally or vertically
• ¼” F.NPT plugged boss on top of body YEAR
• Temperature range of -40°F to +165°F (-40°C to +73°C) WARRANTY
• MAWP: 400 PSIG(27 Bar)

Inlet
Outlet
6.4”

Materials
Body ................................................................................ Ductile Iron
Stem............................................................................Stainless Steel
Seat.............................................................................Stainless Steel
Seat Disc.................................................................Synthetic Rubber
Return Spring..............................................................Stainless Steel Flow Direction

7.4”
Ordering Information
Part Number For Use With: Inlet & Outlet Connections Liquid Capacity at 10 PSIG Drop GPM

A7616 LPG & NH3 2” F.NPT 711-GPM(LPG) 640-GPM(NH3)

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J21
Sight Flow Indicators for Bulk Plants
A7794 and A7796

Application
Designed to promote maximum pump efficiency, these indicators
enable bulk plant operators to visually inspect liquid flow conditions.
With glass on both sides of the indicator, flow can be observed from
either side, even under some poor light conditions. The integral swing
check also serves as a back-check valve to prevent reverse flow and
product loss if the hose fails in a loading operation.

By installing an indicator on the upstream side of the plant pump,


suction conditions can be observed and the pump speed adjusted to
obtain the maximum possible flow rate without cavitation. Additionally,
if an indicator is installed in the piping at the loading rack, just ahead
of the loading hose, the operator can maintain a constant check on
pump conditions.

Both installations are designed to allow for observation to provide


maximum pump efficiency and ensure safe plant pump operation.

In compressor operations a sight flow indicator installed in the liquid


line will give a visual indication when the tank car or transport is
emptied. Compressor operation can then be immediately reversed to
start recovery of the vapor.

A7794
Features
• Durable ductile iron body ensures long, trouble-free operation with
design working pressure of 400 PSIG.
• Glass is polished, ground and tempered after fabrication for
maximum strength up to 2,500 PSIG.
• Set screws minimize loosening of glass retainer rings.
• O-ring glass seals provide for leak-tight operation.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)
J

Materials
Body............................................................................... Ductile Iron
Swing Check............................................................. Stainless Steel
Check Seat Disc..................................... Resilient Synthetic Rubber
Glass......... Polished, Ground, Tempered and tested to 2,500 PSIG

10
REGO

YEAR
WARRANTY

Ordering Information
A
Inlet/Outlet B
Part Number Connections Length
A7794 2” F. NPT 5¾”
A7796 3” F. NPT 7⅜”

J22 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Unloading Adapter for Low Emission 6588LE & 6589LE

Application
Designed for use in conjunction with our 6588LE and 6589LE low
emission filler valves installed on bobtails and transports. Valve is
designed to unload through the 6588LE and 6589LE filler valves.
Stem position is controlled by the hand-wheel with a durable ACME (2.637)

thread for maximum travel with minimal rotation. Stem will open
upper check of filler valve and allow flow out of the tank.
Features & Benefits (7.678)

• V-ring spring loaded pressure stem seal provides for


leak-proof operation. No packing to retighten or replace.
(Ø5.250)
• Circular bridge in globe design and a dropped seat in the
angle design achieve greater flow with less pressure drop.

• Heavy duty rolled ACME stem threads provide quick action


and long service life. (2.637)

• Cap and plug provided for safe storage when not in use
(5.250)
(7.678)
• Durable RegO adapters on inlet and outlet. (5.616)

Materials A7568LE
Body ................................................................................ Ductile Iron
Stem............................................................................Stainless
(5.250) Steel
3¼” M.ACME X 2” M.NPT Adapter..............................Stainless (5.616) Steel
(Ø5.250)
Body........................................................................................ Brass
Screen....................................................................... Stainless Steel J
(2.637)
Gasket.................................................................... Resilient Rubber

(2.637)

(7.678)
(4.866)
(8.082)

(5.250)

(2.637)

(5.250)

(5.616)

10
REGO

YEAR
WARRANTY
(4.866)
(8.082)

(5.250)

Ordering Information
(2.637)
Part Number Inlet Outlet Cap and Plug for Both Ends

A7568LE 3¼” F. ACME 3¼” M. ACME Yes

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J23
Presto-Tap® Universal Service Tech Diagnostic & Leak Test Kit for All Stages of the
Gas System PTU-KIT

Application
Kit with gauges for obtaining pressure readings and leak testing at
tank pressure, first stage, two pound and low pressure (0-20 OZ)
locations.

Features & Benefits


• PT6800 KGA w/adapter – 300 pound ambient temperature gauge
used for leak testing at tank pressure with Presto-Tap® pigtails,
TPF fittings and RegO “READY to GO” series valves.

• PT30- KGA w/adapter – 30 pound gauge for determining lock up


and flow of first stage regulators along with leak testing.

• PT5-KGA - w/adapter 5 pound gauge for determining lock up and


flow in 2 pound systems.

• PTOZ-KGA w/adapter – 0035-inch water column (0-20OZ) gauge


for measuring second stage regulator lock up and flow along with
low pressure leak testing.

• MHA-KIT – Adapter to facilitate use of water manometers and


Helix gauges.

• 316AHW Allen/ Hex key – for plug removal in regulators.

• RCW716 Ratcheting wrench for plug removal and installing


Presto-tap® LDS2000/RV fittings.

• PTFLEX-KIT - 36” Flexible hose with gauge bleeder and


adapters utilized to universally connect all gauging equipment
included and Presto-Tap ® LDS2000/RV fittings.

J • LDS2000/RV – (6) UL Listed fittings with #54 orifice legal installed


at any point in the system. PTU-KIT
• KIT BAG- 12” Denier Nylon tool bag with 8 outer pockets and 15
inner pockets.

Materials
PT6800 KGA w/adapter.................................. Stainless Steel- Brass
PT30- KGA w/adapter ................................... Stainless Steel- Brass
PT5-KGA - w/adapter .................................................... Steel- Brass
PTOZ-KGA w/adapter .....................................................Steel- Brass
MHA-KIT.................................................................................... Brass
3/16 Allen/ Hex key.................................................................... Steel
7/16 Ratcheting wrench.............................................................. Steel
PTFLEX-KIT........................................................... Brass/Composite
LDS2000/RV............................................................................. Brass
KIT BAG.........................................................................Denier Nylon

18
REGO

MONTH
WARRANTY

Ordering Information
Part Number Description

PTU-KIT Universal Service Tech Diagnostic & Leak Test Kit for All Stages of the Gas System

J24 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Presto-Tap® Pressure Gauge with Glow in the Dark 3.5” Display
PTCA-KGA Series

Application
These larger gauges with glow-in-the-dark display are designed for
use with our Presto-Tap® leak detection system for better visibility in
low light areas and after hours service calls.

Features & Benefits


• 40% larger face is easier to read and more accurate due to
larger spacing between the graduations

• The luminescent, glow-in-the-dark face is easier to read in low


light conditions.

• Includes protective cover and a magnet for attaching directly to


the tanks while you conduct the leak test.

PTCA-KGA Series
J

Glow in the Dark


Display

18
REGO

MONTH
WARRANTY

Ordering Information
Accessories(must be ordered seperately)

Part Number Pressure Range Connection Magnet Rubber Cover 36" Flexible Hose 12" Rubber Hose
w/ quick connect w/ quick connect
adapter adapter
PT30CA-KGA 0 to 30 PSIG
¼" M. Flare Yes Yes PTFLEX-KITP PTH-KITP
PT6800CA-KGA 0 to 300 PSIG

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J25
Hose End Adapters for DOT Cylinder Filling
7193D-10 and 7193U-10

Application
Designed to provide quick and easy filling of DOT cylinders with POL
or Type I connections. This adapter may be used with hydraulic and
electric automatic systems or with manual systems in conjunction
with a RegO 7901TB Quick Acting Shut-Off Valve.

These filling connectors have an extended connection on the


handwheel, which makes it possible to connect the loading hose to
valves on cylinders with fixed collars. The handwheel is well outside
the collar for easy operation. 7193U-10

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 250 PSIG(17 Bar)

6"
7193D-10

10
B B REGO
A B
61/8”
B
A
YEAR
¼” NPT WARRANTY
M. POL
(CGA 510)

Ordering Information
Materials
Inlet "A" "B"
Part Number Applications Connection Outlet Connection Nipple Handwheel Adapter
7193D-10 Filling of DOT Cylinders with POL Connections M. POL (CGA 510) Stainless Steel
7193U-10 ¼” M. NPT Brass Brass
J 7193U-10S
Filling of DOT Cylinders with Type I Connections Type 1 Connection (15/16” F. ACME)
Stainless Steel

Connector for DOT Cylinder Filling Adapter


7193T-10

Application
The 7193T-10 Connector is designed for use on the 7193D-10 Filling
Adapters. Connector allows quick connection to the Type I 15/16” M.
ACME threads for operators that fill both POL and Type I valves.

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C) 2
• MAWP: 250 PSIG(17 Bar)

7193T-10

10
REGO

YEAR
WARRANTY

Ordering Information
Part Number Applications Inlet Connection Outlet Connection Materials
7193T-10 Converts 7193D-10 Adapters from POL to a Type 1 Connection F. POL CGA 510 Type 1 Connection (15⁄16” F. ACME) Brass

J26 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Patented Low Emission Hose End Safety Adapter 7193D-10L

Application

10
Low Emission Adapter (1.18 cc at disconnect) designed to provide REGO
quick and easy filling of DOT cylinders with POL connections with
minimal release of product on disconnect. This adapter may be used
with dispensing systems in conjunction with RegO 7901T Series
Quick Acting Shut-Off Valve. Balanced, light weight design for filling YEAR
into 20 # - 200 # cylinders.
WARRANTY

Features
• Meets CARB Low Emission Standards.
• Light weight, easy-to-use.
• Soft Nose M.POL connection.
• Redundant Safety Feature – will only open when connected
to valve.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)
7193D-10L Series

Materials
Body..........................................................................Brass – Knurled
Shaft.......................Stainless Steel – ¼” M.NPT x M.POL (CGA 510)
O-Ring.....................................................................Synthetic Rubber

Ordering Information
Part Number Application Inlet Connection Outlet Connection Materials
7193D-10L Filling of DOT cylinders with POL Connections ¼” M. NPT M. POL (CGA 510) Brass & Stainless Steel

Patented Low Emission Hose End Safety Adapter 7193U-10L J


Application
Low Emission Adapter (1.18 cc at disconnect) designed to provide
quick and easy filling of DOT cylinders with Type 1 connections with

10
minimal release of product on disconnect. This adapter may be REGO
used for dispensing systems in conjunction with RegO 7901T Series
Quick Acting Shut-Off Valve. Balanced, light weight design for filling
into 20 # - 200 # Cylinders
YEAR
WARRANTY
Features
• Meets CARB Low Emission Standards
• Light weight, easy-to-use type 1 Fitting
• Liquid release directed away from operator
• Redundant Safety Feature – will only open when connected
to valve.
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar)

7193U-10L Series

Materials
Body...........................................................................Brass - Knurled
Shaft........... Stainless Steel – ¼” M.NPT x Type 1 (15/16” M. ACME)
O-Ring.....................................................................Synthetic Rubber

Ordering Information
Part Outlet
Number Application Inlet Connection Connection Materials
Filling of DOT cylinders with Type 1 Connection (15/16) F.
7193U-10L ¼” M. NPT Brass
Type 1 Connections ACME

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J27
Hose End Adapter for Lift Truck Cylinder Filling
7193L-10A

Application
The 7193L-10A is designed to provide quick and easy attachment of
the filling hose to DOT cylinders equipped with RegO 7141M check
connectors.
95⁄8”
The 1¼” ACME outlet threads facilitate rapid make-up. When 13⁄8”
connected, back-checks in the adapter and check connector 11⁄4” ACME
automatically open. Low pressure drop between the two ensures high
filling rates. An integral check closes when disconnected, eliminating
the need to close any valves manually to disconnect the charging
hose.
⁄ ” NPT
14

Because a leak-tight seal is formed before the integral check opens or


closes, product loss is kept to an absolute minimum when connecting
or disconnecting the loading hose.

10
REGO

YEAR
WARRANTY
7193L-10A

Ordering Information
Accessories
Body
Part Number Application Inlet Connection Outlet Connection Material Adapter
7193L-10A Filling of Fork Lift Cylinders* ¼” M. NPT 1¼” F. ACME Brass 5760A
J *The 7193L-10A is intended to be permanently attached to the filling hose.
A 5760A adapter enables the 7193L-10A to be attached to the POL connection on the 7193D-10 at regular cylinder filling stations to allow for occasional filling of fork lift cylinders.

J28 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Combination Valve for Bulk Storage Containers
A2805C

Application
Designed for installation on bulk storage containers, this valve
combines a pressure gauge mounting and provision for a fixed tube
liquid level gauge.

The shut-off valve prevents the pressure gauge from being subjected
to constant pressure, thereby prolonging its life and accuracy. The
valve may be closed, and the vent valve opened to vent pressure
from the gauge to permit replacement.

For fixed liquid level gauging, the valve can be mounted at the
maximum permitted filling level. When equipped with a dip tube
threaded ⅛” M.NPT, it can be installed at any convenient level.

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) A2805C

Materials
Body A2805C................................................................. Ductile Iron
Bonnet...................................................................................... Steel
Valve Stem................................................................ Stainless Steel
Vent Stem.................................................................. Stainless Steel
Valve Stem Seal..................................... Resilient Synthetic Rubber
Vent Seal................................................ Resilient Synthetic Rubber
Valve Seat............................................................................... Nylon

10
REGO

J
YEAR
WARRANTY

Ordering Information
Part Number Container Connection Service Connection Liquid Level Vent
A2805C ¾” M. NPT ¼” F. NPT for Gauge Mounting Tee Handle
*Has ⅛” F. NPT opening for installing separate dip tube.

Gritrol Fuel Line Filters 12802


Application
Designed especially for use in liquid motor fuel lines to trap foreign
material which otherwise may damage precision components in the
LP-Gas carburetion system. These filters incorporate an integral
sintered metal filter element in a straight through design.

10
REGO

YEAR
WARRANTY 12802

Ordering Information
Part Number Inlet Connection Outlet Connection
12802 ¼” F. NPT ¼” M. NPT

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J29
Vent Valves 3165C, 3165D, 3165S and TSS3169

Application
Especially designed to bleed off liquid or vapor pressures trapped in

10
transfer lines. When installed in the downstream boss of RegO globe
REGO
and angle valves used at the end of a liquid transfer hose, the bleeder
valve allows for the controlled venting of the product and indicates
to the operator that the valves are closed and he can disconnect the
coupling. They may also be used as a fixed liquid level gauge where
the dip tube is part of the container. YEAR

The 3165C, 3165S and TSS3169 incorporates a No 54 drill size WARRANTY


orifice The 3165D incorporates a No 72 drill size orifice.
An optional instruction plate with “Stop Filling When Liquid Appears’’ 3165C 3165S TSS3169
may be ordered for use with these valves.

Features 1 1⁄8”
• Temperature range of -40°F to +165°F (-40°C to +73°C)
• MAWP: 400 PSIG(27 Bar) 1 1⁄8”
34 ⁄”

Materials
Body (3165)............................................................................. Brass 1⁄4 ”
Body (TSS3169)........................................................ Stainless Steel ⁄”
14
NPT ⁄ ” NPT
14

Seat Disc (3165)..................................... Resilient Synthetic Rubber NPT


Seat Disc (3169)...................................................................... Teflon

Ordering Information
Accessories
Part Number Service Connection Actuation Warning Plate Kit
3165C
Ribbed
3165D LP-Gas Only
¼” M. NPT 2550-40P
3165S Slotted
TSS3169 LP-Gas & NH3 Tee Handle

J Fixed Liquid Level Gauges 3165 Series and TA3169F


Application Materials
Especially designed to provide a visible warning when containers Body (3165)............................................................................. Brass
are filled to the maximum permitted filling level. At the start of the Body (TA3169)........................................................... Stainless Steel
filling operation, with the vent stem opened, the valve discharges Seat Disc (3165)..................................... Resilient Synthetic Rubber
vapor. When the maximum permitted filling level is reached, the Seat Disc (TA3169)................................................................. Teflon
valve discharges liquid. The 3165CF*, 3165CF12.0, 3165SF12.0
and TA3169F12.0 incorporate a No 54 drill orifice; the 3165DF* and
3165DF12.0 incorporate a No 72 drill orifice. They all are normally
furnished with a 12” 3/16” OD dip tube.

An optional instruction plate with “Stop Filling When Liquid Appears’’ 1 1⁄8”
may be ordered for use with these valves. 34 ⁄”
1 1⁄8”

Features
• Temperature range of -40°F to +165°F (-40°C to +73°C) ⁄ ” NPT
14
1⁄4 ”

• MAWP: 400 PSIG(27 Bar) NPT

10
1⁄4 ”

REGO NPT
v = 12”
v = 12”
v = 12”

YEAR
WARRANTY
3165CF12.0 TA3169F12.0
3165CF12.0 TA3169F12.0 3165SF12.0
3165DF12.0
3165DF12.0
Ordering Information
Accessories
Part
Number Service Connection Actuation Dip Tube Length Warning Plate Kit
3165CF*
*
3165DF*
Ribbed
3165CF12.0 LP-Gas Only
¼” M. NPT 2550-40P
3165DF12.0
12”
3165SF12.0 Slotted
TA3169F12.0 LP-Gas & NH3 Tee Handle
J30 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Spanner Wrench for ACME Connectors
3195-50

Application
This aluminum spanner wrench is especially designed for use with
2¼” and 3¼” ACME couplings, adapters and caps.

10
REGO

3195-50

YEAR
WARRANTY

Ordering Information
Part Number For Use With ACME Connector Size
3195-50 2¼” & 3¼”

Needle Valves 1224, 1316 and 1318


Application
These valves are high quality, “true’’ throttling valves. Unlike most
so-called needle valves, both the body seat and stem are tapered to
provide fine, precise control over a wide range of adjustment without
stem galling.

The 1224 may be used as a small, inexpensive shut-off valve


between a pressure gauge and bulk storage container to allow for
convenient gauge replacement.

The 1316 and 1318 provide taper pipe thread by left hand hose
connection threads and are useful in a wide range of torch and fuel J
burner applications where an accurate throttling action is required.
1224

10
REGO

YEAR
C
WARRANTY B
A

MFG Series
MFA Series

Ordering Information
Part A. Inlet B. Outlet C. D.
Number Body Orientation Body Material Connection Connection Height Length
1224WA ¼” M. NPT ¼” M. NPT
1316WA ⅛” M. NPT 19/16” 1¾”
Straight / ” - 18 L.H.
9 16
1318WA Brass ¼” M. NPT
MFG250BF 2"
MFA250B ¼” M. NPT ¼” F. NPT 219/32”
Angle 1 / ”
11 32
MFA25BSS Stainless Steel

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO J31
Pressure Gauges

Application
Especially designed in a variety of sizes and construction for the
LP-Gas and anhydrous ammonia industry.

10
REGO

YEAR
WARRANTY

5575
612-PG
Ordering Information
Inlet Connection
Part Number Service Case Material Maximum Pressure M.NPT Case Size Increment Divisions
2434A-2* 35” w.c. and 1” w.c. and
2½”
2434-2** Steel 20 oz. (Dual) 1 oz.
3226A-3
30 PSIG ½ PSI
2411
Brass
5575 LP-Gas
60 PSIG 2” 1 PSI
5547 Only Steel
5576 Brass ¼”
100 PSIG 2 PSI
1286 Steel

J 948
948B
Brass
300 PSIG 2” 5 PSI

A8060 60 PSIG
NH3 and
A8150 150 PSIG 2½” 5 lb.
LP-Gas
A8400 Steel 400 PSIG
612-PG 1½” 30 PSI
LP-Gas ⅛”
612-G2 0-300 PSIG 2” 5 PSI
Only
612-BM ⅛” Back Mount 1½” 50 PSI
* ¼” Hose Connection
** ⅛” M. NPT Connection

Pressure Gauges Snubber


Application
Pressure snubbers protect your pressure gauge from pressure
spikes, surges and damaging pulsation. Snubbers extend the life of
your pressure gauges because they protect the internal components
from seeing harsh spikes and surges that could cause.

10
REGO

YEAR 948GS
WARRANTY

Ordering Information
Part Number Service Body Material Inlet Connection M.NPT Outlet Connection F.NPT
948GS LP-Gas Only Brass ¼” ¼”

J32 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Repair Kits
Part Number Repair Kit Kit Contents Product Type

903-50 Service Valve: Bonnet stem seat disc assembly; large


hand-wheel; self-tapping screw ..
901 Series Cylinder/Service Valve
903-51 Service Valve: Bonnet stem seat disc assembly; small
hand-wheel; self-tapping screw ..
A2141A6-50 O-Ring seal for female connector
A2141A6 Series
A2141A6M Male Connector
A2141A8-50 0-Ring seal for female connector
A2141A8 Series
A2141A8M Male connector Pull Away Valves
A2141A10 A2141A10-50 0-Ring seal for female connector
A2141A16-50 0-Ring seal for female connector
A2141A16
A2141A16M Male connector
3121-50 Hand wheel; screw; o-rings(2); bonnet gasket; bleeder
3121 stem Unloading Adapter
Wear button; retaining ring; main stem bearing; washer;
A3209D-50 jam ring pressure seal rings (2); main stem retaining ring;
hex screw; poppet assembly; seat disc
A3209D/DT Series A3209D-50T Torsion Spring & Washer
A3209R-80 Pivot Shaft Repair Kit.. Friction washer, jam ring, pres-
sure seal ring(2) & o-ring
Wear button; retaining ring; main stem bearing; washer;
A3211D-50 jam ring pressure seal rings (2); main stem retaining ring;
hex screw; poppet assembly; seat disc
A3211D/DT Series A3209D-50T Torsion Spring & Washer
A3209R-80 Pivot Shaft Repair Kit.. Friction washer, jam ring, pres-
sure seal ring(2) & o-ring
A3212R-50 Gasket; spring; seal housing gasket; jam ring; pressure
seal ring (2); o-ring; retaining ring; wear button & poppet
A3212A-80 Pivot Shaft Repair - Jam ring, Pressure seal ring (2) &
o-ring
Poppet Stem O-ring & Excess Flow Spring LPG 105
A3212R-N105 gpm half coupling 65 gpm full coupling (w/ nameplate
A3212R-K105)
A3212R/RT Series
Poppet Stem O-ring & Excess Flow Spring LPG 175
A3212R-N175 gpm half coupling 100 gpm full coupling (w/ nameplate
A3212R-K175)
Poppet Stem O-ring & Excess Flow Spring 250 gpm
A3212R-N250 half coupling 130 gpm full coupling (w/ nameplate
A3212R-K250)
A3213TLHS Thermal Latch & Helper Spring Kit
Internal Valves
Gasket; spring; seal housing gasket; jam ring; pressure
A3213R-50 seal ring (2); o-ring; retaining ring; wear button; poppet
assembly; o-ring; roll pin & cotter pin
A3213A-80 Pivot Shaft Repair - Jam ring, Pressure seal ring (2) &
o-ring
A3213D-K150 Retaining ring, lock nut, washer, o-ring & excess flow
spring LPG 150 gpm half coupling 125 gpm full coupling
A3213D/DT Series Retaining ring, lock nut, washer, o-ring & excess flow
A3213D-K200
spring LPG 200 gpm half coupling 160 gpm full coupling
A3213D-K300 Retaining ring, lock nut, washer, o-ring & excess flow
spring LPG 300 gpm half coupling 250 gpm full coupling
A3213D-K400 Retaining ring, lock nut, washer, o-ring & excess flow
spring LPG 400 gpm half coupling 325 gpm full coupling
A3213TLHS Thermal Latch & Helper Spring Kit
Gasket; spring; seal housing gasket; jam ring; pressure
A3217A-80G seal ring (2); o-ring; retaining ring; wear button; poppet
assembly; o-ring; roll pin & cotter pin
A3217A Gasket; spring; seal housing gasket; jam ring; pressure
A3217F-50
seal ring (2) & o-ring
A3217A-6 Stem and Linkage Repair Kit
Bumper; cotter pins (3); dirt seal; inner and outer stem
bearing; lever release spring; main seat disc; poppet
A3219FA-80G seat disc; pivot pin locknut; poppet bearing; seal gland
A3219FA gasket; seat seal o-ring; stem; jam ring; stem o-ring; stem
seal rings (3); stop screws; upper and lower flange seal
gaskets

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R1
Repair Kits
Part Number Repair Kit Kit Contents Product Type
Spring washer (2); gasket (main seat); gasket (flange);
A6008-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
A6006 Pressure seal ring (2); jam ring; washer; spring (seal
A6008-80
housing); o-ring
A6000-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
A6008-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
A6008 Pressure seal ring (2); jam ring; washer; spring (seal
A6008-80
housing); o-ring
A6000-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
A6010-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
A6010 Pressure seal ring (2); jam ring; washer; spring (seal
A6010-80
housing); o-ring
A6010-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
VA6010-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
VA6010 Pressure seal ring (2); jam ring; washer; spring (seal
A6010-80
housing); o-ring
A6010-20 Torsional Spring, Adapter, Adapter Pin and handle assy
ESV
Spring washer (2); gasket (main seat); gasket (flange);
A6016-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
A6016 Pressure seal ring (2); jam ring; washer; spring (seal
A6016-80
housing); o-ring
A6016-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
VA6016-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
VA6016 Pressure seal ring (2); jam ring; washer; spring (seal
A6016-80
housing); o-ring
A6016-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
A6024-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
A6024 Pressure seal ring (2); jam ring; washer; spring (seal
A6024-80
housing); o-ring
A6024-20 Torsional Spring, Adapter, Adapter Pin and handle assy
Spring washer (2); gasket (main seat); gasket (flange);
VA6024-50 pressure seal ring (2); am ring; washer (teflon); spring;
lock washer; rubber boot; o-ring; cotter pin (2)
VA6024 Pressure seal ring (2); jam ring; washer; spring (seal
A6024-80
housing); o-ring
A6024-20 Torsional Spring, Adapter, Adapter Pin and handle assy

R2 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Repair Kits
Part Number Repair Kit Kit Contents Product Type

19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;


o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
6532A Series
6542B-50 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
6532R Series Filler Valve: Gaskets; spring; spring guide; stem and seat
6542B-50
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
6533A Series Multivalve® assembly
6542B-50 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
6533R Series Filler Valve: Gaskets; spring; spring guide; stem and seat
6542B-50
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
6542A Series
6542B-50 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R3
Repair Kits
Part Number Repair Kit Kit Contents Product Type

19104-50 Service Valve: Complete multibonnet assembly- bonnet


assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
6542R Series Filler Valve: Gaskets; spring; spring guide; stem and seat
6542B-50
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
6543A Series
6542B-50 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
6543R Series Filler Valve: Gaskets; spring; spring guide; stem and seat Multivalve® assembly
6542B-50
disc assembly; upper body
6542B-80 Filler Valve: Gaskets; spring; spring guide; stem and seat
disc assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
6555D Series
8555-50 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly; upper body
8555-80 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
6555R Series Filler Valve: Gaskets;spring;spring guide; stem & seat
8555-50
disc assembly; upper body
8555-80 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly
L7579-51 Gaskets; spring; spring guide; stem and seat disc assem-
bly; upper body
L6579 Filler Valve
L7579-81 Gaskets; spring; spring guide; stem and seat disc assem-
bly
TA7034-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7034P/LP washer Globe/Angle Valve

7553T-50 Bonnet; gasket; lever assembly; seat retainer assembly;


7053T stem Quick-Acting Valve
7553T-80 Gasket; o-ring; seat disc
7141M 7141M-50 Seat disc and retainer; gasket; o-ring; retaining ring Adapters
7177 7177-50 Diaphragm; gasket; o-ring; seat disc; washer
Cylinder Filling Systems
7188 7188-50 Hydraulic fluid; o-rings; piston; spring; trip latch
A7505-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7505AP washer
A7505A-20 Bonnet assembly
TA7034-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7505AP washer
A7505-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7506AP washer
A7505A-20 Bonnet assembly
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; Globe/Angle Valve
TA7506AP TA7034-50
washer
A7507-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7507AP washer
TA7507-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7507AP washer
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7508AP washers
7507A-20 Bonnet assembly

R4 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Repair Kits
Part Number Repair Kit Kit Contents Product Type

A7509A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7509AP washer
A7509BP A7509-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
washer
TA7509B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7509BP washer
TA7509B-20 Bonnet assembly
A7509A-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7510AP washer
A7509-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7510BP washer
7509B-20 Bonnet assembly
TA7509B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7510BP washer
TA7509B-20 Bonnet assembly
A7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7511AP washer
A7511F-20 Bonnet assembly
TA7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7511AP washer
A7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7511FP washer
A7511F-20 Bonnet assembly
TA7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7511FP washer
A7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7512AP washer
A7511F-20 Bonnet assembly
TA7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7512AP washer
A7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7512FP washer
A7511F-20 Bonnet assembly
TA7511-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7512FP washer Globe/Angle Valve
A7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7513AP washer
7513A-20 Bonnet assembly
TA7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7513AP washer
TA7513-20 Bonnet assembly
A7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7513FP washer
A7513F-20 Bonnet assembly
TA7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7513FP washer
TA7513F-20 Bonnet assembly
A7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7514AP washer
7513A-20 Bonnet assembly
TA7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7514AP washer
TA7513-20 Bonnet assembly
A7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7514FP washer
A7513F-20 Bonnet assembly
TA7513-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7514FP washer
TA7513F-20 Bonnet assembly
A7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7517AP washer
A7515-20 Bonnet assembly
TA7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7517AP washer
TA7515-20 Bonnet assembly
A7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7517FP washer
A7515-20 Bonnet assembly

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R5
Repair Kits
Part Number Repair Kit Kit Contents Product Type

TA7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7517FP washer
TA7515-20 Bonnet assembly
A7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A7518FP washer
A7515-20 Bonnet assembly
TA7515-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
TA7518FP washer Globe/Angle Valve
TA7515-20 Bonnet assembly
7550P Series 7550-15 Bonnet assembly
A7550P Series A7550-15 Bonnet assembly
A7550UP A7550-15 Bonnet assembly
7551P 7550-15 Bonnet assembly
A7551UP A7550-15 Bonnet assembly
7554LV 7554L-20 Bonnet assembly
7554LAV 7554L-20 Bonnet assembly
Quick-Acting Valve
7554SAV 7554S-20 Bonnet assembly
7554SV 7554S-20 Bonnet assembly
19104-50 Service valve: Complete multibonnet assembly; bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service valve: Upper packing for 19104-50 seal rings for
multibonnet assembly only
7556VR Series 19100-50B Service valve: Complete standard bonnet assembly; bon-
net assembly; hand-wheel; self tapping screw
8475-51A Vapor Equalzing: Body; gaskets; spring; stem and seat
disc assembly
8475-81A Vapor Equalzing: Gaskets; spring stem and seat disc
assembly
Multivalve® assembly
19104-50 Service valve: Complete multibonnet assembly; bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service valve: Upper packing for 19104-50 seal rings for
multibonnet assembly only
7556R Series 19100-50B Service valve: Complete standard bonnet assembly; bon-
net assembly; hand-wheel; self tapping screw
8475-51A Vapor Equalzing: Body; gaskets; spring; stem and seat
disc assembly
8475-81A Vapor Equalzing: Gaskets; spring stem and seat disc
assembly
7573D Series 7573D-81 spring stem and seat disc assembly Vapor Equalizing Valve
L7579-51 Gaskets; spring stem and seat disc assembly; upper
body
L7579 L7579-81 Gaskets; spring stem and seat disc assembly
E7579-KIT Extension conversion kit to E7579
7579-50 Gaskets; spring stem and seat disc assembly; upper
7579P body
7579-80 Filler Valve
Gaskets; spring stem and seat disc assembly
SFL7579-50L Extension Kit
SFL7579V Series Gaskets; spring stem and seat disc assembly; upper
SFL7579-51
body
7647S Series 7647B-80A Gaskets; spring stem and seat disc assembly
SF7647V Series SF7647V-80A Gaskets; spring stem and seat disc assembly
7704 Series 7554-21 Bonnet assembly
A7704 Series A7705-50 Flange packing; friction washer; gaskets; seat disc
7705P 7554-20 Bonnet assembly
Globe/Angle Valve
A7705 Series A7705-50 Flange packing; friction washer; gaskets; seat disc
7706P 7554-21 Bonnet assembly
A7706 Series A7705-50 Flange packing; friction washer; gaskets; seat disc
A7707-50 Gaskets; groove pin; jam ring; o-ring; pressure seal rings;
A7707L seat disc; washers
A7707-50 Gaskets; groove pin; jam ring; o-ring; pressure seal rings;
A7708L seat disc; washers
A7797A-4 Bonnet/Stem & Lever Assy Quick-Acting Valve
A7797A-5 Seat Disc & Stem Assy.
A7793A Series Gaskets; groove pin; jam ring; o-ring; pressure seal rings;
A7797-50
seat disc; washers
A7797A-75 Bonnet/Stem Assy

R6 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Repair Kits
Part Number Repair Kit Kit Contents Product Type
A7794 A7794-50 o-ring; gasket; set screw; cotter pin; seat disc
Sight Flow
A7796 A7796-50 o-ring; gasket; set screw; cotter pin; seat disc
A7797A-4 Bonnet/Stem & Lever Assy
A7797A-5 Seat Disc & Stem Assy.
A7797A Series Gaskets; groove pin; jam ring; o-ring; pressure seal rings; Quick-Acting Valve
A7797-50
seat disc; washers
A7797A-75 Bonnet/Stem Assy
A7853A-50 Block v-packing; gaskets; o-rings; piston stem and yoke;
A7853A roll pin; seat disc retainer assembly; springs
Bleeder assembly; bushing; cap; cap screws; filters;
A7883F-50 gaskets; lock washers; needle valve kit; o-rings; retaining
ring; roll pin; screen filter; seal; set screws; springs; stem Internal Valves
A7883 assembly kit; v-ring; x-seal
A7883F-80 Bushing; cylinder cap screws; filters; gaskets; insert;
o-rings; retaining ring; seal disc; v-ring; x-seals
A7883F-150 Gaskets; seal disc; x-seal
TA7894-50 Gaskets; groove pin; jam ring; o-ring; pressure seal rings;
TA7894 seat disc; washers Rail
7901 Series 7901T-50 Bonnet Assy; Gasket & lever Quick-Acting Valve
A8012C 7511A-20 Bonnet Assy
A8012D 7511A-20 Bonnet Assy Multipurpose Valve
A8012E 7511A-20 Bonnet Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc; Globe/Angle Valve
A8016DP washers
A7507A-20 Bonnet Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8016DBC washers
A7507A-20 Bonnet Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8017DH washers
A8017BH-20R Bonnet and Stem Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8017DLP washers
` Bonnet Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8017DP washers
A7507A-20 Bonnet Assy Multipurpose Valve

A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8018DP washers
A7507A-20 Bonnet Assy
7554-21 Bonnet Assy
7579-50 Gaskets; spring stem and seat disc assembly; upper
8117 body
7579-80 Gaskets; spring stem and seat disc assembly
8118P 7554-21 Bonnet Assy
A8016B-50 Gaskets; jam ring; o-ring; pressure seal rings; seat disc;
A8020D washers
7507A-20 Bonnet assembly

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R7
Repair Kits
Part Number Repair Kit Kit Contents Product Type
19104-50 Service Valve: Complete Multi-Bonnet Assembly
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
8475L-50 Filler Valve: Upper body; gaskets; seat disc & retainer
assy; spring
8475L-80 Filler Valve: Gaskets; seat disc & retainer assy; spring
8475L-50L Filler Valve Extension Kit
G8475RL
8475-51A Vapor Equalizing Valve: Upper body; gaskets; seat disc &
retainer assy; spring
8475-81A Vapor Equalizing Valve: Gaskets; seat disc & retainer
assy; spring
3165C Fixed Liquid Level Gauge Multivalve® assembly
3165DB Low Emissions Fixed Liquid Level Gauge
19104-50 Service Valve: Complete Multi-Bonnet Assembly
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
8475L-50 Filler Valve: Upper body; gaskets; seat disc & retainer
assy; spring
G8475RLW
8475L-80 Filler Valve: Gaskets; seat disc & retainer assy; spring
8475L-50L Filler Valve Extension Kit
8475-51A Vapor Equalizing Valve: Upper body; gaskets; seat disc &
retainer assy; spring
8475-81A Vapor Equalizing Valve: Gaskets; seat disc & retainer
assy; spring
G8475RLW 3165C Fixed Liquid Level Gauge Multivalve® assembly
3165DB Low Emissions Fixed Liquid Level Gauge
8540-50 Bleeder valve Assy; packing gland; set screw; washer;
8542 Series key
Relief Manifold
AA8542 Series 8540-50 Bleeder valve Assy; packing gland; set screw; washer;
key
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
8555D Series
8555-50 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly; upper body
8555-80 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly Multivalve® assembly
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
8555R Series Filler Valve: Gaskets;spring;spring guide; stem & seat
8555-50
disc assembly; upper body
8555-80 Filler Valve: Gaskets;spring;spring guide; stem & seat
disc assembly
19101-50 Service Valve: Complete bonnet assembly; bonnet/stem;
8556 o-ring; hand-wheel; self tapping screw Cylinder/Service Valve
19104-50 Service Valve: Complete Multi-Bonnet Assembly
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
8475L-50 Filler Valve: Upper body; gaskets; seat disc & retainer
assy; spring
8475L-80 Filler Valve: Gaskets; seat disc & retainer assy; spring
8593AL Multivalve® assembly
8475L-50L Filler Valve Extension Kit
8475-51A Vapor Equalizing Valve: Upper body; gaskets; seat disc &
retainer assy; spring
8475-81A Vapor Equalizing Valve: Gaskets; seat disc & retainer
assy; spring
8560-50 Bleeder valves; seat ring assy's; pressure seal rings;
A8560 Series packing gland; jam ring; washer; gaskets
Relief Manifold
A8570 Series 8560-50 Bleeder valves; seat ring assy's; pressure seal rings;
packing gland; jam ring; washer; gaskets
A9090 Series A9090-50 Stem Assy & packing gland Rotogage® dial

R8 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Repair Kits
Part Number Repair Kit Kit Contents Product Type

19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;


o-ring; hand-wheel; self tapping screw
9101C Series
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
9101D
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19101-50 Service Valve: Complete bonnet assembly; bonnet/stem;
9101H3 o-ring; hand-wheel; self tapping screw
19101-50 Service Valve: Complete bonnet assembly; bonnet/stem;
9101H5 o-ring; hand-wheel; self tapping screw
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
9101H6
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw Cylinder/Service Valve

19101-50 Service Valve: Complete bonnet assembly; bonnet/stem;


9101P Series o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete Multi-Bonnet Assembly
9101R Series
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
9101Y Series
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
9102C1
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
9102D Series o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
9102D Series assembly; hand-wheel; self tapping screw
19104-50 Service Valve: Complete Multi-Bonnet Assembly
9102R Series
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
9103C Series o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
9103D Series o-ring; hand-wheel; self tapping screw
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19101-50 Service Valve: Complete bonnet assembly; bonnet/stem;
9103T9F o-ring; hand-wheel; self tapping screw Cylinder/Service Valve

19100-50P Service Valve: Complete bonnet assembly; bonnet/stem;


9104 Series o-ring; hand-wheel; self tapping screw
903-50 Service Valve: Bonnet stem seat disc assembly; large
hand-wheel; self-tapping screw ..
9106CO Series
903-51 Service Valve: Bonnet stem seat disc assembly; small
hand-wheel; self-tapping screw ..
19100-50B Service Valve: Complete bonnet assembly; bonnet/stem;
o-ring; hand-wheel; self tapping screw
9107K8A
19104-50 Service Valve: Complete multibonnet assembly- bonnet
assembly; hand-wheel; self tapping screw
19104-50 Service Valve: Complete Multi-Bonnet Assembly
9300R
19104-80 Service Valve: Multi-Bonnet Upper Packing Assembly

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R9
Index
302................................ A45 913PS12G..................... H15 2906F............................ A52 3199W........................... A51 6533A11.7/6533R11.7... C10
302V.............................. A45 913PS12H..................... A53 2906F............................ H14 3199W............................F17 6533R10.5..................... C10
302V9............................ A45 913PS12H..................... H15 2906G............................ A52 3199W........................... H13 6533R11.7..................... C10
302V9LS........................ A45 913PS20........................ A53 2906G............................ H14 3200C............................ G20 6542A12.0..................... C10
597FA............................ A46 913PS20........................ H15 2962.............................. A55 3200L............................. G20 6542A12.0/6542R12.0.. C10
597FB............................ A46 913PS30........................ A53 3119A............................... H6 3226A-3.......................... J31 6542B-50......................... R3
597FC............................ A46 913PS30........................ H15 3120................................ H6 3272E.............................F11 6542B-50......................... R3
597FD............................ A46 913PS36........................ A53 3121................................ H6 3272F.............................F11 6542B-50......................... R3
612-G2........................... J31 913PS36........................ H15 3121-50........................... R1 3272G.............................F11 6542B-50......................... R3
612-PG........................... J31 913PS48........................ A53 3125L............................. D18 3272H.............................F11 6542B-50......................... R3
612-VM........................... J31 913PS48........................ H15 3127G............................ D17 3272H.............................F12 6542B-50......................... R4
901-400......................... B19 948................................. J31 3127G............................ D18 3282A.............................F11 6542B-50......................... R4
901C1............................ B13 948B............................... J31 3127H............................ D18 3282B.............................F11 6542B-50......................... R4
901C3............................ B15 970................................ A51 3127J............................. D18 3282C.............................F11 6542B-80......................... R3
901C5............................ B15 970................................ H13 3127K............................ D17 3292A.............................F11 6542B-80......................... R3
903-50............................. R1 970AS............................ A51 3127K............................ D18 3292B.............................F11 6542B-80......................... R3
903-50............................. R9 970AS............................ H13 3127L............................. D18 3705RC........................... H8 6542B-80......................... R3
903-51............................. R1 970AW........................... A51 3127P............................ D18 4403-30......................... A54 6542B-80......................... R3
903-51............................. R9 970AW........................... H13 3127U............................ D18 5547............................... J31 6542B-80......................... R4
903-400......................... B19 970AX............................ A51 3129G............................ D17 5575............................... J31 6542B-80......................... R4
903-500......................... B19 970AX............................ H13 3129G............................ D18 5576............................... J31 6542B-80......................... R4
903-500......................... C13 970AXS......................... A51 3129H............................ D18 5726B34........................ A44 6542R12.0..................... C10
903-500......................... E27 970AXS......................... H13 3129J............................. D18 5727B34........................ A44 6543A11.1..................... C10
907FP.............................. H9 970HT............................ A51 3129K............................ D17 5754B4.......................... A44 6543A11.1/6543R11.1... C10
912FA20........................ A53 970HT............................ H13 3129K............................ D18 5755B4.......................... A44 6543A11.7..................... C10
912FA20........................ H15 970JR............................ A51 3129L............................. D18 5760A............................ A52 6543A11.7/6543R11.7... C10
912FA30........................ A53 970JR............................ H13 3129P............................ D18 5760A............................ H14 6543R11.1..................... C10
912FA36........................ A53 970S.............................. A51 3129U............................ D18 5760B............................ A52 6543R11.7..................... C10
912FA48........................ A53 970S.............................. H13 3131G............................ D16 5760B............................ H14 6555R10.6....................... C9
912FS12........................ A53 970WXS........................ A51 3132G............................ D16 5760C............................ A52 6555R11.6....................... C9
912FS12........................ H15 970WXS........................ H13 3133G............................ D16 5760C............................ H14 6555R12.0....................... C9
912FS15........................ A53 1212 KIT........................ A54 3135G............................ D16 5760D............................ A52 6584C.............................F28
912FS20........................ A53 1224WA.......................... J32 3135MG......................... D21 5760D............................ H14 6586D.............................F31
912FS20........................ H15 1286............................... J31 3139-18......................... A50 5760S............................ A52 6587EC..........................F27
912FS30........................ A53 1300.............................. A52 3139-26......................... A50 5760S............................ H14 6588LE.......................... H12
912FS30........................ H15 1300.............................. H14 3139-38......................... A50 5761A............................ A52 6589LE.......................... H12
912FS36........................ A53 1316WA.......................... J32 3144-9P........................... H9 5761A............................ H14 7034LP.......................... E14
912FS36........................ H15 1318WA.......................... J32 3144-91........................... H9 5761B............................ A52 7034P............................ E14
912FS40........................ A53 1328.............................. A52 3146...............................F31 5761B............................ H14 7053T............................ E10
912FS48........................ A53 1328.............................. A54 3146S.............................F31 5761C............................ A52 7141F.............................. H6
912JA20........................ A53 1328.............................. H14 3165C............................. J30 5761C............................ H14 7141FP............................ H9
912JA20........................ H15 1331.............................. A52 3165C.............................. R8 5761D............................ A52 7141M............................. H6
912JS12........................ A53 1331.............................. A54 3165C.............................. R8 5761D............................ H14 7141M-50........................ R4
912JS12........................ H15 1331.............................. H14 3165CF........................... J30 5763D............................ H10 7142LF............................ H7
912JS20........................ A53 1332.............................. A52 3165CF12.0.................... J30 5764A............................ H10 7142LM........................... H7
912JS20........................ H15 1332.............................. A54 3165D............................. J30 5764B............................ H10 7172................................. J6
912JS30........................ A53 1332.............................. H14 3165DB........................... R8 5764C............................ H10 7173................................. J6
912JS36........................ A53 1350E............................ A54 3165DB........................... R8 5764D............................ H10 7177............................... J20
912JS36........................ H15 1350R............................ A54 3165DF........................... J30 5764E............................ H10 7177-50 .......................... R4
912PA20........................ A53 1450E............................ A54 3165DF12.0.................... J30 5764W........................... H10 7188............................... J20
912PA20........................ H15 1450R............................ A54 3165S............................. J30 5765D............................ H10 7188-21.......................... J20
912PA30........................ A53 1494-1........................... A52 3165SF12.0.................... J30 5765E............................ H10 7188-50........................... R4
912PA36........................ A53 1494-1........................... H14 3170...............................F29 5765F............................ H10 7188HS.......................... J20
912PA36........................ H15 1519A2...........................F10 3171................................ H5 5765M........................... H10 7188MS.......................... J20
912PA48........................ A53 1519A3...........................F10 3171A.............................. H5 5765PR........................... H9 7193D............................. J20
912PA48........................ H15 1519A4...........................F10 3174-9P........................... H9 5766E............................ H10 7193D-10........................ J26
912PA60........................ A53 1519B4...........................F10 3174-91........................... H9 5766F............................ H10 7193D-10L...................... J20
912PS12........................ A53 1519C2.............................F9 3174-93........................... H9 5767F............................ H10 7193D-10L...................... J27
912PS12........................ H15 1519C4.............................F9 3174C.............................F28 5767G............................ H10 7193L-10A...................... J28
912PS20........................ A53 1584VH......................... A47 3175................................ H5 5767H............................ H10 7193T-10........................ J26
912PS20........................ H15 1584VL.......................... A47 3175A.............................. H5 5767M........................... H10 7193U-10........................ J26
912PS30........................ A53 1584VN......................... A47 3175B.............................. H5 5768G............................ H10 7193U-10L...................... J27
912PS30........................ H15 1586VH......................... A47 3175P.............................. H9 5768H............................ H10 7193U-10S..................... J26
912PS36........................ A53 1586VL.......................... A47 3176...............................F31 5768HVSS..................... H11 7194-1............................ J20
912PS36........................ H15 1586VN......................... A47 3179A.............................. H8 5769H............................ H11 7194H-3.......................... J20
912PS48........................ A53 1588VH......................... A47 3179B.............................. H8 5769HVB....................... H11 7194HD.......................... J20
912PS48........................ H15 1588VL.......................... A47 3180C.............................F29 5769HVP....................... H11 7194M-3A....................... J20
912PS60........................ A53 1588VN......................... A47 3181................................ H5 5769K............................ H10 7194MD.......................... J20
913JS05........................ A53 1708C.............................. H9 3181A.............................. H5 5769K............................ H11 7501L..............................F23
913JS05........................ H15 2070C0............................. J9 3183AC..........................F29 5769KVB....................... H11 7502L..............................F23
913JS05A...................... A53 2071-L25.7....................... J9 3184-90........................... H9 5769M........................... H10 7505AP.......................... E14
913JS05A...................... H15 2071-L39.7....................... J9 3185................................ H5 5769M........................... H11 7506AP.......................... E14
913JS12........................ A53 2139...............................F14 3188A............................ A51 5807.............................. A44 7507A-20......................... R4
913JS12........................ H15 2139A.............................F14 3188A............................ H13 5808.............................. A44 7507A-20......................... R7
913JS20........................ A53 3403-31......................... A50 3188B............................ A51 5820.............................. A44 7507AP.......................... E14
913JS20........................ H15 2302-43......................... A54 3188B............................ H13 5828.............................. A44 7508AP.......................... E14
913JS30........................ A53 2411................................ J31 3188C............................ A51 5829.............................. A44 7509B-20......................... R5
913KL12........................ A53 2434-2............................ J31 3188C............................ H13 5832.............................. A44 7509BP.......................... E14
913KL12........................ H15 2434A............................ A54 3191................................ H5 5833.............................. A44 7510BP.......................... E14
913LS12........................ A53 2434A-2.......................... J31 3194-90........................... H9 5839.............................. A44 7511A-20......................... R7
913LS12........................ H15 2503-19......................... A50 3194-90G........................ H9 6016-60D........................ J19 7511A-20......................... R7
913PS05........................ A53 2503-22......................... A50 3194-90GS...................... H9 6016PN-50..................... J19 7511A-20......................... R7
913PS05........................ H15 2723C.............................F16 3194-91L......................... H9 6016PN-80..................... J19 7511AP.......................... E14
913PS05A..................... A53 2884D.............................F17 3194-91S......................... H9 6016RM.......................... J19 7511FP.......................... E14
913PS05A..................... H15 2906A............................ A52 3194-91V......................... H9 6532A12.0..................... C10 7511FP.......................... E14
913PS08........................ A53 2906A............................ H14 3194C.............................F28 6532A12.0/6532R12.0.. C10 7512AP.......................... E14
913PS10........................ A53 2906D............................ A52 3195................................ H5 6532R12.0..................... C10 7513A-20......................... R5
913PS12........................ A53 2906D............................ H14 3195-50.......................... J31 6533A10.5..................... C10 7513A-20......................... R5
913PS12........................ H15 2906E............................ A52 3195S............................ H11 6533A10.5/6533R10.5.. C10 7513AP.......................... E14
913PS12G..................... A53 2906E............................ H14 3197C.............................F27 6533A11.7..................... C10 7513FP.......................... E14

R10 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Index
7513FP.......................... E14 8475-81A......................... R8 19100-50B....................... R9 A3184-8R.......................F22 A3217DAL260............... G16
7514AP.......................... E14 8475-81A......................... R8 19100-50B....................... R9 A3184-90......................... H9 A3217DAL410................. G9
7514FP.......................... E14 8475-81A......................... R8 19100-50B....................... R9 A3185.............................. H5 A3217DAL410............... G16
7514FP.......................... E14 8475L-50......................... R8 19100-50B....................... R9 A3186.............................F31 A3217DAL510................. G9
7517AP.......................... E14 8475L-50......................... R8 19100-50B....................... R9 A3187S...........................F31 A3217DAL510............... G16
7517FP.......................... E14 8475L-50......................... R8 19100-50B....................... R9 A3194-8R.......................F22 A3217DAR160................ G9
7517FP.......................... E14 8475L-50L....................... R8 19100-50B....................... R9 A3194-90......................... H9 A3217DAR160.............. G16
7518AP.......................... E14 8475L-50L....................... R8 19100-50B....................... R9 A3194-91L....................... H9 A3217DAR210................ G9
7518FP.......................... E14 8475L-50L....................... R8 19100-50P....................... R9 A3194-91S...................... H9 A3217DAR210.............. G16
7518FP.......................... E14 8475L-80......................... R8 19101-50......................... R8 A3194-91V...................... H9 A3217DAR260................ G9
7525B4.......................... A42 8475L-80......................... R8 19101-50......................... R9 A3195.............................. H5 A3217DAR260.............. G16
7525B4.......................... A42 8475L-80......................... R8 19101-50......................... R9 A3195S.......................... H11 A3217DAR410................ G9
7525B34........................ A42 8532AG......................... D21 19101-50......................... R9 A3196.............................F31 A3217DAR410.............. G16
7525B34........................ A42 8533AG......................... D21 19101-50......................... R9 A3198S...........................F31 A3217DAR510................ G9
7534B............................ D15 8540-50........................... R8 19104-50......................... R3 A3209D-50...................... R1 A3217DAR510.............. G16
7534G............................ D15 8540-50........................... R8 19104-50......................... R3 A3209D050................... G12 A3217F-50....................... R1
7550-15........................... R6 8542AG......................... D20 19104-50......................... R3 A3209D-50T.................... R1 A3217LA........................ G16
7550-15........................... R6 8542G............................ D20 19104-50......................... R3 A3209D-50T.................... R1 A3217LA........................ G16
7550P............................ E18 8543G............................ D13 19104-50......................... R3 A3209D080................... G12 A3217OA....................... G11
7550PX.......................... E18 8543T............................ D13 19104-50......................... R4 A3209DT050................. G12 A3217RA....................... G16
7551P............................ E18 8544A375T.................... D13 19104-50......................... R4 A3209DT080................. G12 A3217RA....................... G16
7553T-50 ........................ R4 8544G............................ D13 19104-50......................... R4 A3209OA....................... G11 A3219FA-80G.................. R1
7553T-80 ........................ R4 8544K............................ D13 19104-50......................... R4 A3209R-80...................... R1 A3219FA400L................ G18
7554-20........................... R6 8544T............................ D13 19104-50......................... R4 A3209R-80...................... R1 A3219FA400W.............. G18
7554-21........................... R6 8545-500....................... D24 19104-50......................... R6 A3219TF......................... J19 A3219FA600L................ G18
7554-21........................... R6 8545AK.......................... D14 19104-50......................... R6 A3219TF25..................... J19 A3219FA600W.............. G18
7554-21........................... R7 8546G............................ D13 19104-50......................... R8 A3211D-50....................... R1 A3219RT....................... G20
7554-21........................... R7 8546T............................ D13 19104-50......................... R8 A3211D080.................... G14 A3272E...........................F11
7554L-20......................... R6 8555-50........................... R4 19104-50......................... R8 A3211D110.................... G14 A3272F...........................F11
7554L-20......................... R6 8555-50........................... R4 19104-50......................... R8 A3211OA....................... G11 A3272G..........................F11
7554LAV.......................... E9 8555-50........................... R8 19104-50......................... R8 A3212A-80...................... R1 A3276BC........................F31
7554LV............................ E9 8555-50........................... R8 19104-50......................... R9 A3212OA....................... G11 A3282A................................ F11
7554S-20......................... R6 8555-80........................... R4 19104-50......................... R9 A3212R-50...................... R1 A3282C..........................F11
7554S-20......................... R6 8555-80........................... R4 19104-50......................... R9 A3212R 105.................. G23 A3292A...........................F11
7554SAV.......................... E9 8555-80........................... R8 19104-50......................... R9 A3212R 175.................. G23 A3292B...........................F11
7554SV............................ E9 8555-80........................... R8 19104-50......................... R9 A3212R 250.................. G23 A3292C..........................F11
7556R12.0..................... C11 8555D10.6....................... C9 19104-50......................... R9 A3212R-N105.................. R1 A3292D............................... F11
7560-55......................... D22 8555D11.6....................... C9 19104-50......................... R9 A3212R-N175.................. R1 A3400L4.........................F32
7560-56......................... D22 8555DL11.6..................... C8 19104-50......................... R9 A3212R-N250.................. R1 A3400L6.........................F32
7572-400........................F32 8555DL11.6..................... C8 19104-50......................... R9 A3212R T105................ G23 A3500L4.........................F15
7572C-14A.....................F20 8555R10.6....................... C9 19104-50......................... R9 A3212R T175................ G23 A3500N4........................F15
7572C-15A.....................F20 8555R11.6....................... C9 19104-50......................... R9 A3212R T250................ G23 A3500P4.........................F15
7573D.............................F29 8556.............................. B18 19104-50......................... R9 A3213A-80...................... R1 A3500R6........................F15
7573D-81......................... R6 8560-50........................... R8 19104-80......................... R3 A3213D150................... G21 A3500T6.........................F15
7573DC..........................F29 8560-50........................... R8 19104-80......................... R3 A3213D200................... G21 A3500V6.........................F15
7574...............................F11 8593AL16.0..................... C7 19104-80......................... R4 A3213D300................... G21 A4500Y8.........................F15
7574L..............................F11 8593AL16.0..................... C7 19104-80......................... R4 A3213D400................... G21 A5764D......................... H10
7576................................ H8 8684G............................ D15 19104-80......................... R4 A3213D-K150.................. R1 A5764E.......................... H10
7577V.............................. H8 8685G............................ D15 19104-80......................... R6 A3213D-K200.................. R1 A5764W......................... H10
7579-50........................... R6 9101C1.......................... B13 19104-80......................... R6 A3213D-K300.................. R1 A5765C......................... H10
7579-50........................... R7 9101D11.1..................... B13 19104-80......................... R8 A3213D-K400.................. R1 A5765D......................... H10
7579-80........................... R6 9101D11.7..................... B13 19104-80......................... R8 A3213DT150................. G21 A5765E.......................... H10
7579-80........................... R7 9101H3.......................... B15 19104-80......................... R8 A3213DT200................. G21 A5765F.......................... H10
7579P.............................F22 9101H5.......................... B15 19104-80......................... R8 A3213DT300................. G21 A5767F.......................... H10
7579S.............................F27 9101H6.......................... B15 19104-80......................... R9 A3213DT400................. G21 A5768H......................... H10
7580F-20........................F20 9101P5.......................... B16 19104-80......................... R9 A3213OA....................... G11 A5769H......................... H10
7583G............................ D15 9101P5H....................... B16 19104-80......................... R9 A3213R-50...................... R1 A5769K.......................... H10
7590U.............................F19 9101P6.......................... B16 A1519A2.........................F10 A3213TLHS..................... R1 A6000-20......................... R2
7590U-10........................F20 9101P6H....................... B16 A1519A4.........................F10 A3213TLHS..................... R1 A6000-20......................... R2
7590U-20........................F19 9101R1.......................... B13 A1519A6.........................F10 A3217A-6........................ R1 A6008-50......................... R2
7591U.............................F19 9101R11.1..................... B13 A1519B4.........................F10 A3217A-80G.................... R1 A6008-50......................... R2
7593-20..........................F21 9101R11.7..................... B13 A2137.............................F14 A3217AL160.................... G9 A6008-80......................... R2
7605A-BT....................... J19 9101Y5H....................... B15 A2137A...........................F14 A3217AL160.................. G16 A6008-80......................... R2
7605AP-15..................... J19 9102D11.1..................... B13 A2141A6......................... J10 A3217AL210.................... G9 A6010............................. J14
7605AP-16..................... J19 9102D11.7..................... B13 A2141A6-50.................... R1 A3217AL210.................. G16 A6010-20......................... R2
7647B-80A....................... R6 9102R11.1..................... B13 A2141A6L....................... J10 A3217AL260.................... G9 A6010-20......................... R2
7647DC..........................F26 9102R11.7..................... B13 A2141A6M....................... R1 A3217AL260.................. G16 A6010-50......................... R2
7647SC..........................F26 9103D10.6....................... B9 A2141A8......................... J10 A3217AL410.................... G9 A6010-80......................... R2
7704LP.......................... E17 9103D11.6....................... B9 A2141A8-50.................... R1 A3217AL410.................. G16 A6010-80......................... R2
7704P............................ E17 9103T9F........................ B10 A2141A8L....................... J10 A3217AL510.................... G9 A6016............................. J13
7705P............................ E17 9104PPA........................ B17 A2141A8M....................... R1 A3217AL510.................. G16 A6016-20......................... R2
7706P............................ E17 9104PT10.1................... B17 A2141A10....................... J10 A3217ALPA................... G16 A6016-20......................... R2
7901T............................ E10 9104PT10.7................... B17 A2141A10-50.................. R1 A3217ALPA................... G16 A6016-50......................... R2
7901T-50......................... R7 9106CO..........................B11 A2141A16....................... J10 A3217AR160................... G9 A6016-80......................... R2
7901TA.......................... E10 9107K8A........................ B12 A2141A16-50.................. R1 A3217AR160................. G16 A6016-80......................... R2
7901TB.......................... E10 10538P............................ H8 A2141A16M..................... R1 A3217AR210................... G9 A6024............................. J13
7901TB........................... J20 12472.............................F11 A2697-20R.....................F22 A3217AR210................. G16 A6024-20......................... R2
7901TC.......................... E10 12802............................. J29 A2697-20R.....................F28 A3217AR260................... G9 A6024-20......................... R2
7901TLA.........................E11 12982............................ H13 A2797-20R.....................F22 A3217AR260................. G16 A6024-50......................... R2
7901TLB ........................E11 15774-1......................... A52 A2797-20R.....................F28 A3217AR410................... G9 A6024-80......................... R2
7901TLC.........................E11 15774-1......................... H14 A2805C.......................... J29 A3217AR410................. G16 A6024-80......................... R2
8117............................... E26 19100-50B....................... R3 A3146.............................F31 A3217AR510................... G9 A6586D..........................F31
8118P............................ E26 19100-50B....................... R3 A3149G......................... D16 A3217AR510................. G16 A7505-50......................... R4
8475-51A......................... R6 19100-50B....................... R3 A3149L055.................... D16 A3217ARPA................... G16 A7505-50......................... R4
8475-51A......................... R6 19100-50B....................... R4 A3149L200.................... D16 A3217ARPA................... G16 A7505A-20...................... R4
8475-51A......................... R8 19100-50B....................... R4 A3149MG...................... D16 A3217DAL160................. G9 A7505A-20...................... R4
8475-51A......................... R8 19100-50B....................... R6 A3175.............................. H5 A3217DAL160............... G16 A7505AP....................... E13
8475-51A......................... R8 19100-50B....................... R6 A3175A............................ H5 A3217DAL210................. G9 A7506AP....................... E13
8475-81A......................... R6 19100-50B....................... R8 A3175P............................ H9 A3217DAL210............... G16 A7507-50......................... R4
8475-81A......................... R6 19100-50B....................... R9 A3176.............................F31 A3217DAL260................. G9 A7507A-20...................... R7

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R11
Index
A7507A-20...................... R7 A7797A-4........................ R6 C5763N........................... H9 L6579.............................F22 LV4403SR96VI.............. A25
A7507A-20...................... R7 A7797A-4........................ R7 C5765N........................... H9 L6579.............................F22 LV4403TR4.................... A25
A7507A-20...................... R7 A7797A-5........................ R6 C5767N........................... H9 L6579C...........................F22 LV4403TR4V9............... A25
A7507AP....................... E13 A7797A-5........................ R7 C5769N........................... H9 L7579.............................F22 LV4403TR4VI................ A25
A7508AP....................... E13 A7797A-75...................... R6 D912J12........................ A53 L7579-51......................... R4 LV4403TR9.................... A25
A7509-50......................... R5 A7797A-75...................... R7 D912J20........................ A53 L7579-51......................... R6 LV4403TR9V9............... A25
A7509-50......................... R5 A7797L............................ E6 D912J30........................ A53 L7579-81......................... R4 LV4403TR66.................. A25
A7509A-50...................... R5 A7853A.......................... G27 D912P12....................... A53 L7579-81......................... R6 LV4403TR96.................. A25
A7509A-50...................... R5 A7853A-50...................... R7 D912P20....................... A53 L7579C...........................F22 LV4403TR96V9............. A25
A7509BP....................... E13 A7883F-50....................... R7 D912P30....................... A53 LV404B4........................ A39 LV4403Y1D................... A36
A7510BP....................... E13 A7883F-80....................... R7 D913P12....................... A53 LV404B4V9.................... A39 LV4403Y3D................... A36
A7511-50......................... R5 A7883F-150..................... R7 D913P20....................... A53 LV404B9........................ A39 LV4403Y4...................... A35
A7511-50......................... R5 A7883FK....................... G25 D913P30....................... A53 LV404B9V9.................... A39 LV4403Y4D................... A36
A7511-50......................... R5 A7914A............................ E8 D913P36....................... A53 LV404B34...................... A40 LV4403Y5D................... A36
A7511-50......................... R5 A8012C......................... E19 D913P48....................... A53 LV404B34V9.................. A40 LV4403Y16D................. A36
A7511AP........................ E13 A8012D......................... E19 D6555R10.6.................... C9 LV404B39...................... A40 LV4403Y16RD............... A36
A7511F-20....................... R5 A8012E.......................... E20 D6555R11.6..................... C9 LV404B39V9.................. A40 LV4403Y36D................. A36
A7511F-20....................... R5 A8013D..........................F16 D6555R12.0.................... C9 LV404B46...................... A39 LV4403Y36RD............... A36
A7511F-20....................... R5 A8013DA........................F16 D7556R12.0.................. C11 LV404B46V9.................. A39 LV4403Y46R................. A35
A7511F-20....................... R5 A8013DB........................F16 D8555D10.6.................... C9 LV404B96...................... A39 LV4403Y46RD............... A36
A7511FP........................ E13 A8014C......................... E21 D8555D11.6..................... C9 LV404B96V9.................. A39 LV4403Y56D................. A36
A7512AP....................... E13 A8016-9P......................... H9 D8555DL11.6................... C8 LV404H415.................... A41 LV4403Y56RD............... A36
A7513-50......................... R5 A8016-93......................... H9 D8555R10.6.................... C9 LV404H415V3............... A41 LV4403Y66.................... A35
A7513-50......................... R5 A8016B-50...................... R4 D8555R11.6..................... C9 LV404H420.................... A41 LV4403Y66D................. A36
A7513-50......................... R5 A8016B-50...................... R7 D9101D11.1................... B14 LV404H440.................... A41 LV4403Y66R................. A35
A7513-50......................... R5 A8016B-50...................... R7 D9101D11.7................... B14 LV404H440V9............... A41 LV4403Y66RD............... A36
A7513AP....................... E13 A8016B-50...................... R7 D9101R11.1................... B14 LV404H4620.................. A41 LV5503B4...................... A32
A7513F-20....................... R5 A8016B-50...................... R7 D9101R11.7................... B14 LV404Y9........................ A43 LV5503B4D................... A33
A7513F-20....................... R5 A8016B-50...................... R7 D9102D11.1................... B14 LV404Y9V9.................... A43 LV5503B6...................... A32
A7513FP........................ E13 A8016B-50...................... R7 D9102D11.7................... B14 LV404Y39...................... A43 LV5503B6D................... A33
A7514AP....................... E13 A8016B-50...................... R7 D9102R11.1................... B14 LV404Y39V9.................. A43 LV5503B8...................... A32
A7514FP........................ E13 A8016DBC.................... E22 D9102R11.7................... B14 LV960-48....................... A54 LV5503B16D................. A33
A7515-20......................... R5 A8016DP....................... E23 D9103D10.6.................... B9 LV960-72....................... A54 LV5503B56D................. A33
A7515-20......................... R5 A8017BH-20R................. R7 D9103D11.6..................... B9 LV960-80....................... A54 LV5503G4...................... A38
A7515-20......................... R6 A8017DH....................... E24 D9107K8A..................... B12 LV960-120..................... A54 LV5503H414.................. A34
A7515-50......................... R5 A8017DLP..................... E24 DG8475RL....................... C6 LV3403B44R................. A29 LV5503H614.................. A34
A7515-50......................... R5 A8017DP....................... E24 DP8475RL....................... C6 LV3403B44R................. A30 LV5503H620.................. A34
A7515-50......................... R6 A8018DP....................... E25 DPT7556R12.0.............. C11 LV3403B46R................. A29 LV5503H620V............... A34
A7517AP....................... E13 A8020D......................... E24 DPT9102D11.1.............. B14 LV3403B46R................. A30 LV5503H640.................. A34
A7517FP........................ E13 A8060............................. J31 DPT9102D11.7.............. B14 LV3403B66R................. A29 LV5503H640V............... A34
A7518AP....................... E13 A8150............................. J31 DPT9102R11.1.............. B14 LV3403B66R................. A30 LV5503H814.................. A34
A7518FP........................ E13 A8400............................. J31 DPT9102R11.7.............. B14 LV3403TR...................... A24 LV5503H820.................. A34
A7537L4.........................F13 A8434G......................... D12 E7579.............................F22 LV3403TR9.................... A24 LV5503H840.................. A34
A7537L4F.......................F13 A8434N......................... D12 E7579C..........................F22 LV3403TR9V9............... A24 LV5503Y4D................... A37
A7537N4........................F13 A8436G......................... D12 E7579-KIT....................... R6 LV3403TRV9................. A24 LV5503Y6...................... A35
A7537N4F .....................F13 A8436N......................... D12 EA3209D050................. G13 LV4403-400................... A55 LV5503Y6D................... A37
A7537P4 ........................F13 A8523.............................F13 EA3209D080................. G13 LV4403B1D................... A27 LV5503Y8...................... A35
A7537P4F .....................F13 A8525.............................F13 EA3209DT050............... G13 LV4403B3D................... A27 LV5503Y8D................... A37
A7539R6 .......................F13 A8563AG....................... D23 EA3209DT080............... G13 LV4403B3RD................. A27 LV5503Y16D................. A37
A7539R6F.....................F13 A8563G......................... D23 EA3211D080................. G15 LV4403B4...................... A26 LV5503Y18D................. A37
A7539T6........................F13 A8564AG....................... D23 EA3211D110.................. G15 LV4403B4D................... A27 LV5503Y56D................. A37
A7539T6F ......................F13 A8564G......................... D23 EA3212R105................. G24 LV4403B5D................... A27 LV5503Y58D................. A37
A7539V6 ........................F13 A8573AG....................... D23 EA3212R175................. G24 LV4403B16D................. A27 M3131G........................... C6
A7539V6F .....................F13 A8573G......................... D23 EA3212R250................. G24 LV4403B16RABD.......... A27 MV3132G........................ C6
A7550-15......................... R6 A8574AG....................... D23 EA3212RT105............... G24 LV4403B16RAD............ A27 MV3132G...................... D16
A7550-15......................... R6 A8574G......................... D23 EA3212RT175............... G24 LV4403B16RD............... A27 N970P.............................. H8
A7550-15......................... R6 A9090-50......................... R8 EA3212RT250............... G24 LV4403B36D................. A27 PG8475RL....................... C6
A7550P.......................... E18 A9091-18L........................ J7 EA3213D150................. G22 LV4403B36RABD.......... A27 PG8475RL....................... C6
A7550PX....................... E18 A9091-18LX..................... J7 EA3213D200................. G22 LV4403B36RAD............ A27 PPAP.................................III
A7551P.......................... E18 A9091-18N....................... J7 EA3213D300................. G22 LV4403B36RD............... A27 PT30CA-KGA................. J25
A7568LE........................... J4 A9091-M24.0.................... J7 EA3213D400................. G22 LV4403B46.................... A26 PT912FS20................... A53
A7568LE......................... J23 A9091-M36.0.................... J7 EA3213DT150............... G22 LV4403B46D................. A27 PT912JS12.................... A53
A7571LA.......................... H4 A9091-M48.0.................... J7 EA3213DT200............... G22 LV4403B46R................. A26 PT912JS20.................... A53
A7571LB.......................... H4 A9091-M60.0.................... J7 EA3213DT300............... G22 LV4403B46RD............... A27 PT912PS12................... A53
A7575L2.......................... H4 A9091-M72.0.................... J7 EA3213DT400............... G22 LV4403B56D................. A27 PT912PS20................... A53
A7575L3.......................... H4 A9091R............................ J8 EA6010........................... J17 LV4403B56RABD.......... A27 PT912PS48................... A53
A7575L4.......................... H4 A9092R............................ J8 EA6016........................... J17 LV4403B56RAD............ A27 PT913JS12.................... A53
A7575L5.......................... H4 A9093RS.......................... J8 EA6024........................... J17 LV4403B56RD............... A27 PT913PS12................... A53
A7616............................. J21 A9093TS.......................... J8 EA7853A....................... G28 LV4403B66.................... A26 PT6542A12.0................ C10
A7624............................. J21 A9094RS.......................... J8 EFA6010......................... J18 LV4403B66D................. A27 PT6542A12.0/6542R12.0.C10
A7704LP........................ E17 A9094TS.......................... J8 EFA6016......................... J18 LV4403B66R................. A26 PT6542R12.0................ C10
A7704P.......................... E17 A9095RS.......................... J8 EFA6024......................... J18 LV4403B66RA............... A31 PT6543A11.1................. C10
A7705-50......................... R6 A9095TS.......................... J8 FA6010........................... J16 LV4403B66RA9............. A31 PT6543A11.1/6543R11.1.C10
A7705-50......................... R6 AA3126L030.................. D16 FA6016........................... J16 LV4403B66RAB............. A31 PT6543A11.7................. C10
A7705-50......................... R6 AA3126L250.................. D16 FA6024........................... J16 LV4403B66RABD.......... A27 PT6543A11.7/6543R11.7.C10
A7705P.......................... E17 AA3126L312.................. D16 FN1355............................. J5 LV4403B66RAD............ A27 PT6543R11.1................. C10
A7706P.......................... E17 AA3130UA250............... D16 FN1356............................. J5 LV4403B66RD............... A27 PT6543R11.7................. C10
A7707-50......................... R6 AA3130UA265............... D16 FN1357............................. J5 LV4403H222.................. A28 PT6800CA-KGA............. J25
A7707-50......................... R6 AA3135MA250.............. D21 FVA6010......................... J16 LV4403H414.................. A28 PT7556R12.0................ C11
A7707L............................ E7 AA3135MA265.............. D21 FVA6016......................... J16 LV4403H420.................. A28 PT9102R1..................... B13
A7708L............................ E7 AA3135MUA250............ D20 FVA6024......................... J16 LV4403H4614................ A28 PT9102R11.1................. B13
A7793A ........................... E5 AA3135MUA265............ D20 G8475RL......................... C6 LV4403H4620................ A28 PT9102R11.7................. B13
A7793L............................ E6 AA3135UA250............... D16 G8475RL......................... C6 LV4403H6614................ A28 PTU-KIT.......................... J24
A7794............................. J22 AA3135UA265............... D16 G8475RLW...................... C6 LV4403SR4................... A25 RDM.............................. G10
A7794-50......................... R7 AA8532MA250.............. D21 G8475RLW...................... C6 LV4403SR4VI................ A25 RTG2831N375.............. D19
A7796............................. J22 AA8532MA265.............. D21 HA7513AP..................... E15 LV4403SR9................... A25 RTG2831V375............... D19
A7796-50......................... R7 AA8533MA250.............. D21 HA7514AP..................... E15 LV4403SR66................. A25 SF7647V08.2.................F24
A7797-50......................... R6 AA8533MA265.............. D21 HA7517AP..................... E15 LV4403SR66VI.............. A25 SF7647V08.8.................F24
A7797-50......................... R7 AA8542UA250............... D20 HA7518AP..................... E15 LV4403SR96................. A25 SF7647V09.3.................F24
A7797A............................ E5 AA8542UA265............... D20 SF7647V11.0..................F24

R12 Copyright © 2023 RegO 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com
Index
SF7647V11.1..................F24 SS8002G....................... D18 SS8022U....................... D18 TA7511-50....................... R5 TA7517FP...................... E13
SF7647V11.9..................F24 SS8002H....................... D18 T3131G......................... D16 TA7511AP...................... E13 TA7894-50....................... R7
SF7647V-80A.................. R6 SS8002J........................ D18 T3132G......................... D16 TA7511FP...................... E13 TSS3169........................ J30
SFL7579-50L................... R6 SS8002K....................... D18 TA3169F12.0.................. J30 TA7512AP..................... E13 VA6010........................... J14
SFL7579-51..................... R6 SS8002L........................ D18 TA7034-50....................... R4 TA7513-20....................... R5 VA6010-50....................... R2
SFL7579VE07.5.............F25 SS8002N....................... D18 TA7034-50....................... R4 TA7513-20....................... R5 VA6016........................... J13
SFL7579VE08.9.............F25 SS8002P....................... D18 TA7034-50....................... R4 TA7513-50....................... R5 VA6016-50....................... R2
SFL7579VE10.6.............F25 SS8002U....................... D18 TA7034LP...................... E13 TA7513-50....................... R5 VA6024........................... J13
SFL7579VE11.1.............F25 SS8021G....................... D18 TA7034P........................ E13 TA7513-50....................... R5 VA6024-50....................... R2
SFL7579VE12.3.............F25 SS8021H....................... D18 TA7505AP..................... E13 TA7513-50....................... R5 VA8436G....................... D12
SFL7579VE13.0.............F25 SS8021J........................ D18 TA7506AP..................... E13 TA7513AP..................... E13 VA8436N....................... D12
SFL7579VE13.8.............F25 SS8021K....................... D18 TA7507-50....................... R4 TA7513F-20..................... R5 W3132G........................ D16
SFL7579VE15.1.............F25 SS8021L........................ D18 TA7507AP..................... E13 TA7513F-20..................... R5 X1584VH....................... A49
SFL7579VE17.1.............F25 SS8021N....................... D18 TA7509B-20..................... R5 TA7513FP...................... E13 X1584VL........................ A49
SS8001G....................... D18 SS8021P....................... D18 TA7509B-20..................... R5 TA7514FP...................... E13 X1584VN....................... A49
SS8001H....................... D18 SS8021U....................... D18 TA7509B-50..................... R5 TA7515-20....................... R5 X1586VH....................... A49
SS8001J........................ D18 SS8022G....................... D18 TA7509B-50..................... R5 TA7515-20....................... R6 X1586VL........................ A49
SS8001K....................... D18 SS8022H....................... D18 TA7509BP..................... E13 TA7515-20....................... R6 X1586VN....................... A49
SS8001L........................ D18 SS8022J........................ D18 TA7510BP..................... E13 TA7515-50....................... R5 X1588VH....................... A49
SS8001N....................... D18 SS8022K....................... D18 TA7511-50....................... R5 TA7515-50....................... R6 X1588VL........................ A49
SS8001P....................... D18 SS8022L........................ D18 TA7511-50....................... R5 TA7515-50....................... R6 X1588VN....................... A49
SS8001U....................... D18 SS8022P....................... D18 TA7511-50....................... R5 TA7517AP..................... E13

100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com Copyright © 2023 RegO R13
LP-Gas & Anhydrous Ammonia Equipment
Phone: 336-449-7707
Fax: 336-449-6594

100 Rego Drive, Elon, NC 27244 USA

regoproducts.com

ecii@regoproducts.com

CATALOG L-500

PRINTED IN THE USA 12.7-1223-0788

2023

You might also like