N2XY.

PR Insulated Control Cables without


U1000 R2V Shielding

IEC 60 5 02-1
0.6/1KV

APPLICATIONS :
Cables used in low current control cabling of
machinery and equipment in technical and industrial
installations.
TEMPERATURES :
Maximum Permanent Allowable Temperature: 90°C
Maximum Allowable Short Circuit Temperature : 250°C

CONSTRUCTION / SEC T I ON :
- From 2 to 37 conductors assembled in a bundle
of concentric layers .
- Standard sections : 1.5 a n d 2.5mm²
MINIMUM RADIUS OF CURVATURE:
N2XY - Definitive installation: R= 4D
1 - During installation : R= 8D
Control
CONSTRUCTION :
Cable CONDUCTOR : Class 1 Hard Copper

INSULATION : Polyethylene
OUTER JACKET: BLACK PVC.
Cross-linked, PR or XLPE.
Products can be manufactured
on request:
STUFFING : Extrvudé PVC - With PVC sheath Resistant to
filling for multiconductors hydrocarbons (HR)
- With PVC jacket Flame retardant /
No
fire propagator (FR)
- With PVC sheath FR/RH
CONDITIONING:
On a wooden
turret.
N2XY.PR Insulated Control Cables with U1000 R2V Shielding

IEC 60 5 02-1

0.6/1KV

A PPL IC ATIONS :
Shielded cables used in low- current control cabling of machinery and equipment in technical and
industrial installations.
T EMPER ATURES :
Maximum Permanent Allowable Temperature: 90°C Maximum
Allowable Short Circuit Temperature: 250° C

C ONS T R U C T ION / S EC T I ON :
- Fro m 2 to 3 7 co n d u cto rs a sse mbled in a b u n d le o f co n centric la ye rs. -
Standard sections : 1.5 a n d 2.5mm²

MINIMUM RADIUS OF C U RVAT U R E :


1 - Definitive installation : R= 4D
2 - During installation : R= 8D

CONSTRUCTIO N :

CONDUCTOR : Hard copper ,


Class 1or Wired copper, Class 2

INSULATION: Cross-linked
polyethylene,PR or XLPE..
FILLING: Extruded filling
made of PVC for Multiconductors
METAL SHIELD : OUTER SHEATH : PVC Black.
Copper bands Products can be made on demand :
- With PVC sheath Resistant to hydrocarbons (RH)
- With PVC jacket Fire retardant / Non fire propagator (FR)
- With PVC sheath FR/RH

C OND I T IONING :
On a wooden turret.

ADDRESS: Industrial Zone of Biskra, PB 131, RP


CALL CENTER :
7000, Biskra - Algeria
Phone : +213 (0) 33 53 77 77
PHONE : +213 (0) 33.53.79.02
Mobile : +213 (0) 770 17 63 43
FAX : +213 (0) 33.53.77.66 / +213 (0) 33.53.79.21
+213 (0) 560 55 15 20
ALGIERS OFFICE : 16 Tourelle Street Hydra-
Mail : centreappels@enicab.dz
Algier
Web-Site: www.enicab.dz
PHONE/FAX : +213 (0) 21.60.63.71