Appendix C
Appendix C
Appendix C
Melter Communications
This appendix describes the installation and use of the Nordson
Configuration Manager (NCM) communications utility. With this utility you
can:
Software Availability
If you do not already have the NCM utility, you can download it from the
internet by navigating to www.enordson.com/support.
If you do not have a connection to the internet, you can request a software
CD from your Nordson representative.
System Requirements
The following hardware and software requirements are necessary to install
and run Blue Series software:
You are downloading the software from www.enordson.com onto a PC that can not be
connected to the melter, but the PC does have a CD-RW and the PC that is connected to
the melter does have a CD drive
OR
You have a CD with the software and you have a PC with a CD drive that can be
connected to the melter
Self-extracting span diskette set: You are downloading the software from www.enordson.com onto a PC that cannot be
connected to the melter and the PC that is connected to your melter only has a 3.5-inch
BlueSeriesSpan.exe floppy drive
When the installation file is executed, an installation wizard will detect your
operating system and start the installation routine.
NOTE: Installing the NCM for the first time also installs the latest version of
the melter's firmware.
If you are installing from the span diskette set, insert Disk 1, and
then locate and double‐click on the file Setup.exe.
NOTE: Windows XP, 2000, and NT users must have administrator rights in
order to remove software from their PC.
Connect a serial cable between the PC COM port (selected during the
software installation routine) and the serial port connection (COM port) on
your melter's control panel.
4 5 6
1 2 3
The first time you download and install Configuration Manager, the latest
version of the melter's firmware is also downloaded.
5. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates “CONNECTED”.
6. Click Save Settings.
The Save As dialog box appears.
7. Type a file name to identify the group of settings you are saving, and then
click Save.
The save settings progress bar indicates the status of the save. When the
save is complete, the melter automatically returns to the scan mode.
NOTE: If you are using the NCM to save multiple variations of melter
settings, use a file naming convention that will allow you to easily
associate each settings file (.ncm extension) with its related process or
end‐use.
NOTE: The version of firmware that is loaded on your melter appears on the
control panel when the melter is first switched on.
During the upgrade process, all current melter settings are downloaded and
saved on your PC. After upgrading or restoring a melter's firmware, you can
use the NCM to restore the pre‐upgrade settings.
7. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates Connected.
8. Click Upgrade.
The Select Upgrade dialog box appears.
9. In the Available Upgrades list, select the firmware version you want to
upload to the melter, and then click Ok.
The upgrade warning message appears.
10. Click OK.
The Upgrade in Progress dialog box appears. The upgrade can take as
long as 12 minutes. When the upgrade is complete, the Success dialog
box appears and the melter restarts.
CAUTION! Once the uprade progress bar appears, do not interrupt the
upgrade process for any reason. Interrupting the upgrade can corrupt the
melter's firmware, which will require replacement of the IC chip
(IC service kit P/N 1018817).
Troubleshooting
Using Nordson Configuration Manager
Symptom/Message Action
After selecting a device and the COM port, an Access Denied PC-to-Blue communications may be running or another
message appears. application may be using the COM port. Close Internet Explorer
and end the communications connection (if prompted). Close all
other applications.
Melter in UPLOAd mode, the update process has not been Cycle power to the melter at the local power disconnect switch.
initiated, and you want to stop and exit the UPLOAd mode, but CAUTION: Ensure that the firmware update process is not
you cannot get the melter out of UPLOAd. running before taking power off of the melter.
UPLOAd does not appear on the melter’s display when you press You must cycle the control switch while holding the Setup and left
the Setup and left display scroll keys. display scroll keys.
Attempted a firmware update, but the melter display still indicates Using the local power disconnect switch, cycle power to the
UPLOAd. melter, and then re-attempt the update.
OR If the update is unsuccessful or the melter will not reboot, the
Attempted a firmware update, but the PC has stopped responding central processor chip may be corrupted. Replace the CPU
or was interrupted during the update process. board.