0% found this document useful (0 votes)
29 views2 pages

Excalibur 309/309L-17: Typical Applications Key Features

Uploaded by

Wael Mansour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views2 pages

Excalibur 309/309L-17: Typical Applications Key Features

Uploaded by

Wael Mansour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

STICK (SMAW) ELECTRODE

Excalibur 309/309L-17
AWS E309-17, E309L-17 • Stainless

Key Features Typical Applications


Flux coating provides for smooth arc transfer Joining stainless steel to mild or low alloy steel
in the flat and horizontal positions ASTM A240 Type 309S
Designed for joining stainless steel to mild or
low alloy steel
Conformances
AWS A5.4/A5.4M: 2006 E309-17, E309L-17
Q2 Lot® - Certificate showing actual deposit
composition and calculated ferrite number ASME SFA-A5.4: E309-17, E309L-17
(FN) available online ABS: E309-17, E309L-17
CWB/CSA W48-06: E309-17, E309L-17
Designed with low carbon levels to help
eliminate carbide precipitation in high Welding Positions
temperature service All, except vertical down

DIAMETERS / PACKAGING
Diameter Length 8 lb (3.6 kg) 10 lb (4.5 kg)
in (mm) in (mm) Easy Open Can Easy Open Can
3/32 (2.4) 12 (300) ED033100
1/8 (3.2) 14 (350) ED033101
5/32 (4.0) 14 (350) ED033102
3/16 (4.8) 14 (350) ED033103

MECHANICAL PROPERTIES (1) – As Required per AWS A5.4/A5.4M: 2006


Yield Strength(2) Tensile Strength Elongation Ferrite
MPa (ksi) MPa (ksi) % Number
Requirements
AWS E309-17 Not Specified 550 (80) min. 30 min. Not Specified
AWS E309L-17 Not Specified 520 (75) min. 30 min. Not Specified
Typical Performance(3) - As-Welded 455-490 (66-71) 585-620 (85-90) 37-45 7-11

DEPOSIT COMPOSITION(1) – As Required per AWS A5.4/A5.4M: 2006


%C(4) %Cr %Ni %Mo %Mn
Requirements - AWS E309L-17 0.04 max. 22.0-25.0 12.0-14.0 0.75 max. 0.5-2.5
(3)
Typical Performance 0.02-0.04 23.5-24.0 13.0-13.5 0.05-0.09 0.7-0.9
%Si %P %S %Cu
Requirements - AWS E309L-17 1.00 max. 0.04 max. 0.03 max. 0.75 max.
Typical Performance(3) 0.72-0.77 )0.03 )0.01 )0.17

TYPICAL OPERATING PROCEDURES


Current (Amps)
Polarity(5) 3/32 in (2.4 mm) 1/8 in (3.2 mm) 5/32 in (4.0 mm) 3/16 in (4.8 mm)
DC+ 40-80 75-110 95-150 130-200
AC 40-80 75-110 95-150 130-200

IMPORTANT: SPECIAL VENTILATION AND/OR EXHAUST REQUIRED


Fumes from the normal use of some welding products can contain significant quantities of components - such as chromium and manganese - which can lower the 5.0 mg/m3 maximum exposure guideline for general welding fume.
BEFORE USE, READ AND UNDERSTAND THE MATERIAL SAFETY DATA SHEET (MSDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER.
(1)
Typical all weld metal. (2)Measured with 0.2% offset. (3)See test results disclaimer below. (4)AWS Requirement for E309-17 is 0.15% max. carbon. (5)Preferred polarity is listed first.

200 ı THE LINCOLN ELECTRIC COMPANY


Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

T E S T R ESU LT S
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to
prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors,
including, but not limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification
testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.

CUS T OM E R A SSI STA N C E P O L I C Y


The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our
customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond
to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees,
however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not
warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter
any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty
of fitness for any customers’ particular purpose is specifically disclaimed.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole
responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service
requirements.

Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.

THE LINCOLN ELECTRIC COMPANY


22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A.
Phone: +1.216.481.8100 • www.lincolnelectric.com
© Lincoln Global, Inc. All Rights Reserved.
Issue Date 01/12