Catalogue 12 Booklet
Catalogue 12 Booklet
Heart of Refrigeration
F
IS
LT
O
TRUST
90
01
IN
er
tif
Every product is thoroughly checked as per defined standards to ensure its quality.
ie
DI
d
= Pressure Drop-The evaporator must have sufficient space for the circulation of the refrigerant without too much pressure drop between the
I extend a sincere invitation to all industry stake holders, associates, technology leaders,
patent technology holders and related industry stalwarts to join hands for a joint mission of safe outlet and the inlet.
and clean environment as a social responsibility. = Temperature-The evaporator must have enough surface to absorb the required heat load in order to ensure the temperature difference
development of super energy-efficient, cleaner technologies and to innovate products that commercially as walk-in chambers and are used for the storage
Applications:
= Food processing, preservation and distribution.
= Comfort air-conditioning.
OIL SEPARATORS About us
Prime function of Oil Separator is to separate oil from the refrigerant and Established in 1981 by Mr. Avinash Chander, DALTON INDIA is India's leading manufacturer specialising in manufacturing
return it to the compressor before it can enter other components of the Reciprocating Hi-Speed & Slow-Speed Compressors, Air-Cooled & Water-Cooled Condensing Units, Couple-Drive
system. This increases the life of compressor. Compressor Units, Cold Rooms, Evaporators, Shell n Tube Condensers, Chillers, Oil Separators, Suction Accumulators,
= Oil separators can also act as discharge mufflers to quiet compressor Refrigeration Vacuum Pumps and Other Accessories.
pulsation and vibration noises.
We are dedicated in designing & manufacturing highest quality products for the refrigeration industries around the globe.
= By installing an oil separator, it keeps the heat exchanges on both the low
Our technical expertise has established the company as a renowned and recognised manufacturer of the market,
and high sides of the system free to do what they are designed for,
without being penalised by insulating oil films. supplying and exporting products worldwide.
= Oil Separators should always be installed in the discharge line, between Dalton India has earned a reputation for its superior quality and highly innovative products which are designed keeping in
the compressor and the condenser mounted securely in a vertical mind the following things:
position.
= Efficient use of resources.
= Before proceeding with the installation, the oil separator must be
charged with some amount of oil through outlet in order to actuate the = Low operating cost.
TRUS
OF T
SHELL N TUBE CONDENSERS
L
S EA
ied
Ce
rtif
IA The shell n tube heat exchanger has two major components-
IND =
08
1: 20
900
TON
ISO
DAL
round tubes mounted inside a cylindrical shell.
= The tubes are thin-walled tubing produced specifically for use in
heat exchangers.
= The shell cylinder can be fabricated from rolled plate or from
piping (up to 24 inch diameters).
= One fluid runs through the tubes, and another fluid flows over
the tubes (through the shell) to transfer heat between the two
fluids. The set of tubes is called a tube bundle, and may be
composed of several types of tubes: plain, longitudinally
finned, etc.
We manufacture shell n tube Condenser and Chillers in SS & MS.
Tailor made designs as per customer specification are also
manufacturered.
Applications:
The shell n tube heat exchanger is by far the most common type of
heat exchanger used in industry. It can be fabricated from a wide
range of materials both metallic and non-metallic. Design
pressures range from full vacuum to 6,000 psi. Design
temperatures range from -250 degC to 800 degC.
Shell n tube heat exchangers can be used in almost all processes
of heat transfer applications.
DALTON INDIA’S CONDENSING UNITS DALTON INDIA REFRIGERATION COMPRESSORS
AL OF
SE
TR
DAL ISO
90
UST
01
TON :2
00
8C
IND d
Applications
IA
Ice Plants TECHNICAL DATA DI-A8
Ice Cream Plants
Cold Rooms DISPLACEMENT 736.9 CU.CM
Chilling & Freezing
CYLINDER 4 NOS.
Mortuary
Features BORE 73MM
Non - CFC
AIR COOLED CONDENSING UNITS 2 TON AIR COOLED CONDENSING UNITS 3 TON Energy Saving STROKE 40MM
FOR SINGLE PHASE / THREE PHASE POWER FOR SINGLE PHASE / THREE PHASE POWER Heavy Duty
Environment Friendly RPM 800-1440
Advanced Technology
FLYWHEEL 9” X 4 BELT
Couple Drive Condensing Unit 4.4° 123980(15.52) 135630(14.50) 147040(13.40) 191150(14.50) 204320(12.86) 217200(11.10) 40°
DALTON INDIA’S HIGH SPEED couple drive condensing unit fitted with high -1.1° 99660(14.26) 109470(13.60) 119090(12.80) 155270(14.26) 166390(12.80) 177240(11.46) 30°
speed 'DI - Q' Series compressor and standard 3 phase motor ranging from
-6.7° 78728(12.80) 86990(12.46) 95100(11.80) 124520(13.40) 133920(12.40) 143080(11.34) 20°
5.0 HP to 10.0 HP @ 1440 RPM. We make Oil Separators & Suction
Accumulators, Shell n Tube Condensers, other standard refrigeration -12.0° 60800(11.20) 67750(11.0) 74600(10.60) 98260(12.30) 106200(11.56) 113970(10.70) 10°
accessories like Filter Drier, Hand Shut Valve/ Solenoid Valve, Suction &
-18.0° 45580(9.30) 51450(9.40) 57240(9.30) 76050(11.0) 82800(10.50) 89400(10.0) 0°
Discharge gauges, LP-HP switches etc.
Available in Water-Cooled & Air-Cooled setup, suitable for High Temperature, -23.0° 32610(7.50) 37560(7.80) 42450(7.80) 57120(9.40) 62830(9.20) 68420(8.80) -10°
Medium Temperature & Low Temperature for 3.0 T.R to 7.5 T.R.
-29.0° 21750(5.42) 25920(6.0) 30080(6.20) 41296(7.60) 46160(7.70) 50900(7.50) -20°
COUPLE DRIVE CONDENSING UNITS
DI- series couple drive units available in models-
FROM: 5HP TO 10HP RANGE
1. DI-Q5 CC5 2. DI-Q5 CC7.5 3. DI-Q7 CC7.5 4. DI-Q7 CC10 -34.0° -- -- 19960(4.52) 28360(5.90) 32540(6.0) 36600(6.20) -30°
DI-A6 DI-Q4
SUCTION VALVE 1-3/8’’ CONNECTION SUCTION VALVE 7/8 CONNECTION
(10HP,12.5HP,15HP) (3HP-5HP)
DISCHARGE VALVE 1-1/8’’ CONNECTION DISCHARGE VALVE 7/8 CONNECTION
178180(10.20) 189402(8.80) 10.0⁰ 52950 (5.16) 58200 ( 4.80) 63368 (4.36) 82635 (4.89) 88593 (4.26) 94414 (3.97) 50⁰
4.4° 108112(12.30) 118276(11.50) 128220(10.60) 166690(11.50) 40°
4.4⁰ 42942 (4.86) 47380 (4.60) 51728 (4.25) 67664 (4.68) 72698 (4.16) 77630 (3.81) 40⁰
-1.1° 86912(11.30) 95464(10.80) 103848(10.10) 135402(11.30) 145096(10.20) 154568(9.08) 30°
-1.1⁰ 34230 (4.44) 37980 (4.30) 41665 (4.06) 54710 (4.56) 58984 (4.06) 63160 (3.71) 30⁰
-6.7° 68656(10.10) 75858(9.86) 82930(9.38) 108584(10.60) 116774(9.82) 124776(9.0) 20°
-6.7⁰ 26725 (3.94) 29900 (3.89) 33020 (3.73) 43600 (4.26) 47228 (3.97) 50770 (3.63) 20⁰
-12.0° 53016(8.86) 59084(8.70) 65054(8.40) 85686(9.74) 92616(9.16) 99382(8.48) 10°
-12.0⁰ 20290 (3.38) 22975 (3.37) 25627 (3.31) 34100 (3.87) 37190 (3.67) 40210 (3.43) 10⁰
-18.0° 39740(7.38) 44864(7.46) 49920(7.34) 66322(8.66) 72202(8.32) 77944(7.86) 0°
-18.0⁰ 14830 (2.76) 17110 (2.84) 19364 (2.84) 26084 (3.40) 28717 (3.31) 31290 (3.15) 0⁰
-23.0° 28430(5.92) 32748(6.12) 37018(6.18) 49810(7.40) 54792(7.26) 59658(6.98) -10°
-23.0⁰ 10180 (2.11) 12024 (2.26) 14033 (2.33) 19246 (2.86) 21480 (2.84) 23682 (2.76) -10⁰
-29.0° 18962(4.28) 22608(4.72) 26226(4.92) 36008(6.06) 40244(6.06) 44386(5.96) -20°
-29.0⁰ -- 7930 (1.65) 9573 (1.80) 13500 (2.28) 15454 (2.33) 17330 (2.32) -20⁰
-34.0° -- -- 17404(3.58) 24732(4.68) 28372(4.84) 31926(4.88) -30°
WEIGHT 58 KG WEIGHT 62 KG
CAPACITY DATA IN BTU/Hr (POWER IN KW) CAPACITY DATA IN BTU/Hr (POWER IN KW)
140⁰ [ 60⁰ ] ⁰F 130⁰ [ 54.4⁰ ] ⁰F 120⁰ [ 48.8⁰ ] ⁰F 110⁰ [ 43.3⁰ ] ⁰F 100⁰ [ 37.7⁰ ] ⁰F 90⁰ [ 32.2⁰ ] ⁰F 140⁰ [ 60⁰ ] ⁰F 130⁰ [ 54.4⁰ ] ⁰F 120⁰ [ 48.8⁰ ] ⁰F 110⁰ [ 43.3⁰ ] ⁰F 100⁰ [ 37.7⁰ ] ⁰F 90⁰ [ 32.2⁰ ] ⁰F
SST ⁰C RPM > 1280 RPM > 1440 SST ⁰F SST ⁰C RPM > 1280 RPM > 1440 SST ⁰F
-18.0⁰ 0⁰ -18.0⁰ 0⁰