SUBMITTED SAMPLE ANALYTICAL REPORT


SGS Reference: JS24-174.001
Client Reference: Wood Pellet Date Issued: 25 September 2024
Client Reference 2.: Date(s) Tested: 18 September 2024
Sample Type: Solid Bio Fuels Principal: CV. MITRA BIOMASS MANDIRI
Sample Received From: Client Address: Jl. Negara No. 19 RT.000 RW.000
Sample Description: Plastic bag, good condition without seal Bantan Timur, Medan Tembung
Date Sample received: 18 September 2024 08:50:00 AM City, State, Postal: Kota Medan, Sumatera Utara
Seal Numbers: Country: Indonesia
Date Confirmed: 18 September 2024 10:35:00 AM Attention: Thomas

The sample(s), to which the findings recorded herein (the "FINDINGS") relate, was (were) drawn and / or provided by the Client or a third party acting on Client's directions. The
Findings constitute no warranty of the sample's representativity of all the goods and strictly relate to the sample(s). The Company accepts no liability with regard to the origin or
source from which the sample(s) is /are said to be extracted.
Additional Information 1
5.437 kg Wood Pellet sample supplied by Client
Sample was packed in waterproof plastic bag, good condition, without seal
Sample nominal top size is around 30 mm

Analysis performed in accordance with ISO Standards or other International Standards and SGS Procedures.

As-Received As-Determined Dry Basis (db) Dry Ash-Free


Basis (ar) Basis (ad) Basis (daf)

Proximate Analysis Moisture % 11,5 2,6 ----- -----


Moisture (Total) # Ash # % 2,7 3,0 3,1 -----
Moisture (as-determined) # ISO Volatile Matter # % 71,6 78,8 80,9 83,5
Fixed Carbon (calculation by difference) % 14,2 15,6 16,0 16,5
Total Sulfur # % 0,02 0,02 0,02 0,02

Gross Calorific Value # kcal/kg 4125 4540 4661 4809


ISO 1928 Net CV, constant pressure kcal/kg 3788 4227 4356 -------
ISO 1928 Net CV, constant volume kcal/kg 3806 4244 4372 -------
NCV(v) requires H analysis, NCV(p) requires CH analysis
Ultimate Analysis Moisture (Total) # Moisture (as-determined) # As-Received As-Determined Dry Basis (db) Dry Ash-Free
Basis (ar) Basis (ad) Basis (daf)

Total Carbon # % 43,9 48,3 49,6 51,2


Total Hydrogen (includes H in moisture) # % 6,49 6,01 5,87 6,06
Total Nitrogen # % 0,13 0,14 0,14 0,15
Total Sulfur # % 0,02 0,02 0,02 0,02
Ash # % 2,7 3,0 3,1 -----
Oxygen by diff.(includes O in moisture) % 46,76 42,53 41,27 42,57
Total % 100,00 100,00 100,00 100,00
Moisture % (11,5) (2,6) ------- -------
Hydrogen (excludes H in moisture) % 5,20 5,72 DB & DAF H & O values exclude H & O in
Oxygen (excludes O in moisture) % 36,55 40,22 moisture

Chlorine (Cl) %,adb 0,01

Signed and dated For and on behalf of


PT. SGS Indonesia - Jambi Aditia Setiawan (Coal Lab Coordinator)
25 September 2024

Aditia Setiawan (Coal Lab Coordinator) Natural Resources Jl. Kasang Pudak Komp. Pergudangan Blok A No.4 RT.19, Kumpeh Ulu, Muaro Jambi.
0741 3609190 www.sgs.com
Member of SGS Group

This document is issued by the Company under its General Conditions of Service accessible at following link: http://www.sgs.com/en/Terms-and-Conditions.aspx
Attention is drawn to the limitation of liability, indemnification and jurisdictional issues defined therein.

Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.

1 of 2
METHODS

SGS Reference: JS24-174.001

Client Reference: Wood Pellet Date Issued: 25 September 2024


Client Reference 2.: Date(s) Tested: 18 September 2024
Sample Type: Solid Bio Fuels Principal: CV. MITRA BIOMASS MANDIRI
Sample Received From: Client Address: Jl. Negara No. 19 RT.000 RW.000
Sample Description: Plastic bag, good condition without seal Bantan Timur, Medan Tembung
Date Sample received: 18 September 2024 08:50:00 AM City, State, Postal: Kota Medan, Sumatera Utara
Seal Numbers: Country: Indonesia
Date Confirmed: 18 September 2024 10:35:00 AM Attention: Thomas

ACCREDITION STATUS: SGS Laboratory: SELECT * if analysis is included in the SGS Accreditation; Select # if analysis is NOT included in the SGS Accreditation.
Third Party Laboratory (internal or external): SELECT **, if analysis is performed by an Accredited - Third Party Laboratory", SELECT ## if analysis is performed a NON-Accredited Third Party Laboratory.
ACCREDITATION TEST STATUS
* SGS Accredited Test; # SGS Non
Accredited Test, ** Third Party Lab -
Name of Accreditation Body, Type, & Accredited, ## Third Party Lab - Non
Method Standard Executing Laboratory Registration No. Accredited Accreditation Test Status Uncertainty of Measurement
Moisture (Total Moisture)# ISO 18134-1 - 2022 SGS Jambi # Non Accredited Test
Moisture (Analysis Moisture)# ISO 18134-3 - 2023 SGS Jambi # Non Accredited Test
Ash # ISO 18122 - 2022 SGS Jambi # Non Accredited Test
ISO Volatile Matter # ISO 18123 - 2023 SGS Jambi # Non Accredited Test
Fixed Carbon (calculation by difference) By Calculated SGS Jambi # Non Accredited Test
Total Sulfur # ISO 19579 - 2006 SGS Jambi # Non Accredited Test
Gross Calorific Value # ISO 18125 - 2017 SGS Jambi # Non Accredited Test
Ultimate Analysis (C,H,N, Oxygen calculation by difference)# ISO 16948 - 2015 SGS Jambi # Non Accredited Test
Chlorine (Cl) ISO 587 - 2020 SGS Samarinda # Non Accredited Test
Physical Attributes of Sample
Sample preparation ISO 14780 - 2019 SGS Jambi # Non Accredited Test

NOTE: ALL Tests subcontracted to a Third Party Laboratory (internal or external), or marked as " #, ## Not Accredited ", are not included in the SGS ISO 17025 Laboratory Accreditation.
Additional information required by the Accreditation Body.:-

Signed and dated For and on behalf of


PT. SGS Indonesia - Jambi Aditia Setiawan (Coal Lab Coordinator)
25 September 2024

Aditia Setiawan (Coal Lab Coordinator) Natural Resources Jl. Kasang Pudak Komp. Pergudangan Blok A No.4 RT.19, Kumpeh Ulu, Muaro Jambi.
0741 3609190 www.sgs.com
Member of SGS Group

This document is issued by the Company under its General Conditions of Service accessible at following link: http://www.sgs.com/en/Terms-and-Conditions.aspx
Attention is drawn to the limitation of liability, indemnification and jurisdictional issues defined therein.
Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.

2 of 2

You might also like