Lab Filtration Solutions Guide
Lab Filtration Solutions Guide
CONTENT/INDEX
Micro Separations Syringe Filters ( FOR SAMPLE PREPARATION)
PES MEMBRANE
MCE MEMBRANE
PP FILTER
VACCUME MANIFOLD
MICRO-BIOLOGY
Unit Manifold
Micro Separations Micro Glass Fiber Tape Roll Type-MGFBM (BAM TAPE ROLE)
FEATURES:-
GHPLC certified for Low Extractable
IC Certified for Low Levels of inorganic Extractable(s)
Color coding for Easy Identification
SPECIFICATION:-
MGD/X 13 mm MGD/X 25mm MGD/X 33MM
Housing Polypropylene Polypropylene Polypropylene
Filtration area 1.3cm² 4.6cm²
Maximum pressure 100 psi(6.9 bar) 75 psi(5.2 bar)
Volume holdup full 50 µl (approx.) 250 µl (approx.)
housing with air purge
Flow direction Flow should enter from the Flow should enter from the Flow should enter from
inlet inlet the inlet
Inlet connection Female luer lock Female luer lock Female luer lock
Outlet connection Male luer Male luer Male luer
Sterilization Autoclave at 121°C (131° C Autoclave at 121°C (131° Autoclave at 121°C (131°
Max) at 15 psi for 20 min C Max) at 15 psi for 20 C Max) at 15 psi for 20
min min
Glass Micro Fibre pre 100% borosilicate, MGF-1 100% borosilicate, MGF-1 100% borosilicate, MGF-
filtration media µm-0.7µm µm-0.7µm 1 µm-0.7µm
ORDERING INFORMATION:-
Catalogue Membrane Pore Catalogue Quantity/Pac Catalogue number
number size(µm) number k
Microsep-13mm syringe Microsep-25mm syringe filter-Non Microsep-33mm syringe
filter-Non sterile sterile filter- Non sterile
MPNN-13-02 Nylon 0.22µm MPNN-25-02 100 MPNN-33-02
MPNN-13-04 Nylon 0.45µm MPNN-25-04 100 MPNN-33-04
MPPV-13-02 PVDF 0.22µm MPPV-25-02 100 MPPV-33-02
MPPV-13-04 PVDF 0.45µm MPPV-25-04 100 MPPV-33-04
MPPT-13-02 PTFE 0.22µm MPPT-25-02 100 MPPT-33-02
MPPT-13-04 PTFE 0.45µm MPPT-25-04 100 MPPT-33-04
MPPE-13-02 PES 0.22µm MPPE-25-02 100 MPPE-33-02
MPPE-13-04 PES 0.45µm MPPE-25-04 100 MPPE-33-04
MPCA-13-02 CA 0.22µm MPCA-25-02 100 MPCA-33-02
MPCA-13-04 CA 0.45µm MPCA-25-04 100 MPCA-33-04
MGD/X Syringe Filters
The MGD/X range is specifically designed for high particulate loaded samples. Constructed of a pigment
–free polypropylene housing with a pre filtration stack of micro separations MGF (micro glass fibre media),
these filters eliminate sample contamination and allow you to filter even the most difficult samples with less
hand pressure.
APPLICATIONS:-
MGD/X Syringe Filers are ideal for heavily particulate laden sample found in:
TYPICAL APPLICATIONS:-
SPECIFICATIONS:-
Color White
Material Nylon
Reaction to water Hydrophilic
Pore size 0.2-5 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)
Narrow pore sizes distribution for improved surface capture and analysis.
Low level of extractable
Gridded cellulose Nitrate Membrane recommended for sample preparation, Microbiological studies
Particle counting for liquids and aerosols
Color White
Material Cellulose Nitrate
Reaction to water Hydrophilic
Pore size 0.2-5 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION
Catalogue Membrane Pore Diameter Solvent Quantity/Pack
number size(m) resistant
Micro Separations Cellulose Acetate membrane filter combines high flow rates with very low
absorption characteristics.
TYPICAL APPLICATIONS:-
Color White
Material Cellulose Acetate
Reaction to water Hydrophilic
Pore size 0.2-5.4 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
Cat.no. Diameter Qty/pk (pcs) Material Pore Size µm
MCA-02-25 25 100 Cellulose Acetate, 0.22µm
MCA-02-47 47 100 white, plain
MCA-02-90 90 50
MCA-04-25 25 100 0.45µm
MCA-04-47 47 100
MCA-04-90 90 50
MCA-06-25 25 100 0.65µm
MCA-06-47 47 100
MCA-06-90 90 50
MCA-08-25 25 100 0.8µm
MCA-08-47 47 100
MCA-08-90 90 50
MCA-12-25 25 100 1.2µm
MCA-12-47 47 100
MCA-12-90 90 50
PES Membrane (MPPE)
This membrane has very low protein biding characteristics, high liquid flow rates and throughput (long life), and
low extractable. PES’s hydrophilic characteristics allow it to be used with both liquids and dry gases, makes it
suitable for a verity of environments.
TYPICAL APPLICATIONS:-
Color White
Material PES
Reaction to water Hydrophilic
Pore size 0.22-0.45µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
TYPICAL APPLICATIONS:-
SPECIFICATIONS:-
Color white
Material Mixed Cellulose Acetate
Reaction to water Hydrophilic
Pore size 0.22-1.2 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100 pcs
ORDERING INFORMATION:-
Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)
TYPICAL APPLICATIONS:-
SPECIFICATIONS:-
Color White
Material PTFE
Reaction to water Hydrophobic
Pore size 0.1-5 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
SPECIFICATIONS:-
Color White
Material PTFE
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142
mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
SPECIFICATIONS :-
Color white
Material PVDF
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142 MM
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
TYPICAL APPLICATIONS:-
Color White
Material PP
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
SPECIFICATIONS:-
Type- MGF/4- Micro Glass fiber Filter
MGF/5
Thickness 0.45 mm
Weight 75 gm2
Maximum service 500oC
temperature
Steam Autoclave Yes
ORDERING INFORMATION:-
Cat. No. Pre-filter Quantity Diameter Solvent Pore
pack resistance Size(µm)
FEATURES:-
100% integrity tested during manufacturing
Nylon membrane capsule is recommended for filtering aqueous solutions
Dual layer PES membrane capsules filters provide efficient for critical aqueous solutions
Hydrophobic PTFE membrane capsule filters are designed for use with organic solvents and chemically
aggressive solutions
Polypropylene and Glass Fiber filter capsules are usually used as pre-filters
Manufactured in clean room facilities under ISO Quality System.
FEATURES:-
Low hold up volumes and extractable
Materials are in compliance with FDA-
Manufactured in class 10,000 clean room which is ISO certified
SPECIFICATIONS:-
1. Filter media available – PES/Nylon
2. Housing core and support Material- Polypropylene
3. Sealing technology - Thermal bonding
4. Filling Bell - Polycarbonate
5. Pore size Available – 0.1/0.2 µm
6. Normal Dimensions – housing length (without filling bell)93/122mm(without vent) 45 mm
7. Inlet – 1/4" NPT
8. Outlet – ¼ to 3/8” Stepped Hose Barb with filling bell
9. Max operating temp- 60oC @ 2.1 bar
10. Max operating press- 4.1 bar@ambient temp
11. Endotoxin levels - <0.25 EU/ml using Limulus Amoebocyte Lysate LAL test
12. Biological safety – Material pass USP class VI
13. Sterilization – pre sterilized available, non-sterile can be autoclave at 121oC for 30min
14. Package – individual poly-bag wrapped , 1 pc per pack.
MICRO-BIOLOGY
Micro Separations® Membrane Filter (MGCE/MGCN)
Micro Separations Sterile individually packed gridded membrane filters are widely used in the food, beverage,
pharmaceutical industries for microbiology analysis of water and other liquids.
FEATURES:-
Sterile individually packed
A range of membrane pore sizes are available to meet wide variety of applications
Consistent performance
Lot traceability
SPECIFICATIONS:-
Membrane material Mixed cellulose Ester or Cellulose
Nitrate
Filter Diameter 47 mm
Filter Surface Gridded / Plain
Filter Color White
Pore Size 0.22/0.45/0.8 µm
ORDERING INFORMATION:-
Cat. No. Color Pore size Diameter Grid/ plain Membrane Packing
MGCE-02-47 WHITE 0.22 µm 47 mm Gridded Cellulose Esters 100
MGCE-04-47 0.45µm 47 mm Cellulose Esters
MGCE-08-47 0.8 µm 47 mm Cellulose Esters
MGCN-02-47 WHITE 0.22 µm 47 mm Gridded Cellulose Nitrate 100
MGCN-04-47 0.45µm 47 mm Cellulose nitrate
MGCN-08-47 0.8 µm 47 mm Cellulose nitrate
Micro Funnel Unit
The micro-fit unit is a disposable filtration device for bio-burden testing of liquid samples including water,
process samples or final products. It is designed for optimizing and securing the laboratory work.
Applications:-
Ideal for quality control analysis of aqueous fluids used in pharmaceutical production, water and food &
beverage applications
Disposable filter funnels eliminate the possibility of sample cross contamination
Reduce contamination and labor work
Ready to use pre sterilized
Key features:-
Universall
y adaptable design fits directly on most filter manifolds
Validated ink grids for no inhibitory effect on microbial recovery and no inference with colony counting
SPECIFICATIONS:-
Material of construction Cellulose Esters/ Cellulose Nitrate
Thickness 150µm
Pore size 0.2µm-0.45µm
Water flow rate ≥200ml/min@250mm vacuum
Retention efficiency LRV>7for S. maracseins (atec14756 pirem2)
Variants With pad/ without pad
Filtration surface 12.56cm2
Sterilization method ETO/Gamma
Maximum operating temp 45oC
ORDERING INFORMATION:-
MICRO FUNNEL WITH PAD
Cat. No. Description Pore size Quantity
MFGCNP-02-47(S) Micro-fit filtration unit, white gridded CN 0.22 25pices/pkt
membrane,0.22/100ml
MFGCNP-04-47(S) Micro-fit filtration unit, white gridded CN 0.45 25pices/pkt
membrane,0.45/100ml
MFGMCEP-02- Micro-fit filtration unit, white gridded MCE 0.22 25pices/pkt
47(S) membrane,0.22/100ml
MFGMCEP-04- Micro-fit filtration unit, white gridded MCE 0.45 25pices/pkt
47(S) membrane,0.45/100ml
It has the same features with traditional manifold besides it is more flexible and has light structure.
FEATURES:-
Whole equipment body is designed with stainless steel, surface is minor finished and is easy to clean and sterilize.
Triplet filtering head design can be simultaneously suction filtration to improve work efficiency.
Filtering head can quickly sterilize via flame for continuous lab operation.
Filtering head can be easily dismounting and mounting and individual do moist heat sterilization
Multiple filtering heads are available for two kinds of two kinds of membrane specification at 47mm and 50mm
STERILIZATION:-
By autoclaving (max, 134oC)
By dry heat sterilization (max, 180oC)
By flaming
ORDERING INFORMATION:-
Cat. No. Applicable Dimension Weight
membrane
diameter
Micro-fit SS M301SS 47/50 mm 43.5x10.3x12 cm 1.5 kg
Manifold, 3-place
Rugged polypropylene housings have broad chemical compatibility, hydrophobic membranes, including PTFE,
PVDF, fiber glass laminated, provide high efficiency removal of airborne bacteria and particulate under dry or
moist conditions.
These devices act as barriers on air lines. They prevent the entry of water and aerosols into sensitive equipment
and also protect the lab environment from aerosolized pathogens. Vent filters can also enable air to enter and
exit vessels such as bioreactors, while maintaining the sterility of the interior environment.
Application:-
Venting receiving vessels
Isolation or environmental chambers
Bioreactors
Fermentation tanks
Carboys, and other small containers
Use in-line for low-pressure sterile air/gas delivery to instruments and culture vessels
Bio-isolation of a vacuum source
Flushing instruments and cleaning parts.
Order Information:-
FDF5
FEATURES:-
Strong protein adsorption capability, stronger signal, low background;
High mechanical strength good ductility;
Broad chemical compatibility.
ORDERING INFORMATION:-
Cat. No. Size Pore size µm Packaging
MPV-02-21 7x8.4 cm sheet 0.2 PVDF
MPV-02-22 15x15 cm sheet
MPV-02-33 20x20 cm sheet
MPV-02-24 26cm x 3.3 m roll
MPV-02-25 30cm x 3m roll
MPV-04-51 7x8.4 cm sheet 0.45
APPLICATION:-
Venting bioreactors
Fermentation tanks
Culture vessels
Carboys
Filling machines
Autoclaves
Transfer vessels
Convenient
Each filter is individually numbered for easy sample tracking.
Each box of 50 filters is sequentially leveled for easy control.
Precise
Low tare mass provided for accurate gravy metric determination. The unique thermally stable design
eliminates curling, keep the membrane flat, and make fitter robot friendly.
Clean
Manufacture under clean room conditions, these chemically resistance, low chemical background filter permit
sensitive interference free determinations.
SPECIFICATIONS:-
ORDERING INFORMATION:-
SPECIFICATIONS:-
Properties Unit of Measure Value Variations
Filter Media n/a Micro Glass Fiber n/a
Thickness Mm 0.28 ± 15
Basic weight gm2 53 Maximum
Dimensions inches 8”x10” ± 1/16
203mm x 254mm
Pore size(particle Retention µm 1.6 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.95 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 4.3 Max
Initial Filtration speed (secs/100ml)Herzberg 62 Max
Tensile Strength MD N/15mm 5.5 Min.
Wet Burst Psi 0.3 -
Binder - No Binding -
Loading Capacity - High -
Recommended for Gravimetric determination of air born particle, absorption method for air pollution
monitoring Equivalent to WHATMAN grade-GF/A
ORDERING INFORMATION
Diameter Catalog no. Quantity packs
Grade MGF/1
Filter Circle
25mm MGF/1-25 All item are 100
37mm MGF/1-37 pcs per pack
47mm MGF/1-47
70mm MGF/1-70
82mm MGF/1-82
90mm MGF/1-90
110mm MGF/1-110
125mm MGF/1-125
Filter Sheet
203mmX MGF/1-203254 100 Sheets/Pkt
254mm
Micro Separations Micro Glass Fiber Filter Type-MGF/2000
Micro separations high purity Micro Glass Fiber filters are manufactured from 100% borosilicate glass and
produced especially for use in high volume PM-10 air sampling equipment that collect atmospheric particulates
and aerosols. It’s enabling detailed chemical analysis of trace pollutants to take place with the minimum of
interference or background.
SPECIFICATIONS:-
ORDERING INFORMATION:-
Diameter Catalog no Quantity packs
Filter circle
47 mm MGF/2000-47 100 pcs/pack
Filter sheets
203 mm x254 mm MGF/2000-203254 100 sheets/pkt
Micro Separations Micro Glass Fiber Filter Type-MGF/3
Micro separations high purity Micro Glass Fiber filters are manufactured from 100% borosilicate glass and
produced especially for use in high volume PM-10 air sampling equipment that collect atmospheric particulates
and aerosols. It’s enabling detailed chemical analysis of trace pollutants to take place with the minimum of
interference or background.
SPECIFICATIONS:-
ORDERING INFORMATION:-
SPECIFICATIONS:-
ORDERING INFORMATION:-
125mm MGF/934AH-125
Micro Separations Quartz Micro Fiber Filter Type-QMF/1
Micro separations high purity Quartz Micro Fiber filter is manufactured from 100% micro-quartz fiber and
widely used for air sampling in acidic gasses, stacks, flues and aerosols particularly at high temperature up to
900oC.
SPECIFICATIONS:-
ORDERING INFORMATION:-
SPECIFICATIONS
Properties Unit of measurement values Variation
Filter Media Glass Micro Fiber - Max
Basic weight g/m2 49 Max
Thickness mm 0.14
Pressure drop (Kpa) 0.3µm @5.3cm/sec 20 Max
Efficiency (%) 0.3µm @5.3cm/sec 99.9 Max
MD Tensile N/M 780 Max
Binder - Yes
Air Flow Rate s/100ml/1.56cm2 12 Max
Recommended for Beta attenuation monitor for PM2.5 & PM 10 Monitoring
ORDERING INFORMATION:-
SPECIFICATIONS:-
ORDERING INFORMATION:-
SPECIFICATIONS
Properties Unit of Measure Value Variations
Filter Media n/a Cellulose n/a
Thickness mm Single or double -
Particle retention for single µm 10µm -
Thickness
Particle retention for double µm 6µm Min.
thicknesss
Maximum operating Temperature Centigrade (oC) 105oC Max
Binder - No Binding -
Thickness of Thimbles used as per Application Smoke Stack gas monitoring
ORDERING INFORMATION
APPLICATIONS:-
ORDERING INFORMATION:-
Narrow pore size distribution for improved surface capture and analysis
Low level of extractable to ensure sample integrity
SPECIFICATIONS:-
ORDERING INFORMATION:-
Catalogue no Membrane Pore size (µm) Diameter (mm) Solvent Quantity /pack
resistant
MCN-0.2 Cellulose Nitrate 0.2 47 medium 100
MCN-0.45 Cellulose Nitrate 0.45 47 Medium 100
Micro Separations Cellulose Filter
Qualitative Filter
These filters are used in qualitative technique to determine and identify material.
Grade-MS-1
11µm – a medium retention and flow rate filter for routine application- including soil analysis and seed testing
procedure, food industry testing, air pollution monitoring and gas detection.
Quantitative Filter
Micro Separations quantitative filters are designed for gravimetric analysis and preparation of samples of
instruments analysis.
Grade-MS-40
8µm general purpose ashless filter with medium speed and particle retention. Application includes gravimetric
analysis, the filtration of solutions prior to atomic absorption spectrophotometry and in air pollution monitory.
Grade-MS-41
20-25µm- the fastest ashless filter is recommended for analytical procedures involving large particles or
gelatinous precipitates as such iron or aluminum hydroxides. Also used in quantitative air pollution analysis for
determining gaseous compound at high flow rates.
Grade-MS-42
2.5µm- filter with the finest particle retention of cellulose filters. Typically analytical precipitates include
barium sulphate, metastenic acid and finely precipitated calcium carbonate.
SPECIFICATIONS:-
Grade Particle Air flow rate Ash Thickness Basis Wet Dry Tensile MD
retention s/100ml/in2 (%) (µm) weight burst burst dry
liquid g/m2 (psi) (psi) (N/15mm)
(µm)
Qualitative
MS-1 11 10.5 0.06 180 88 0.3 16 39.1
Ashless Quantitative
MS-40 8 19.3 .007 210 92 0.5 16 46.7
MS-41 20 3.4 .007 215 84 0.3 10 27.2
MS-42 2.5 107 .007 200 100 0.7 25 55.8
ORDERING INFORMATION
Qualitative Standard Filter
Circles
Catalogue no.
Diameter (mm) Grade-MS-1 Quantity/box
47 MS-1-47 100
55 MS-1-55 100
90 MS-1-90 100
110 MS-1-110 100
125 MS-1-125 100
150 MS-1-150 100