You are on page 1/ 36

MICRO SEPARATIONS

CONTENT/INDEX
Micro Separations Syringe Filters ( FOR SAMPLE PREPARATION)

Nylon Membrane (MEMBRANE FITERS )

Hydrophobic PTFE Membrane

HYDROPHILIC PTFE MEMBRANE

HYDROPHILIC PVDF MEMBRANE

PES MEMBRANE

MCE MEMBRANE

PP FILTER

GLASS FIBER FILTER

VACCUME MANIFOLD

CAPSULE FILTERS,FOR LAB WATER PURIICATION


Point-of-use Capsule filter

MICRO-BIOLOGY

Micro-Disc Membrane Filter

Micro Funnel Unit

Unit Manifold

Ultra Filtration Membrane (PES)

Blotting Membrane PVDF (Blotting Membrane)

Disposable Vent Filter

Micro Separations PTFE Filter Type-PMTF2.5

Micro Separations Micro Glass Fiber Filter Type-MGF/1

Micro Separations Micro Glass Fiber Filter Type-MGF/2000

Micro Separations Micro Glass Fiber Filter Type-MGF/3

Micro Separations Micro Glass Fiber Filter Type-MGF/934AH

Micro Separations Quartz Micro Fiber Filter Type-QMF/1

Micro Separations Micro Glass Fiber Tape Roll Type-MGFBM (BAM TAPE ROLE)

Micro Separations Micro Glass Fiber Thimbles Type-MGFT

Micro Separations Micro Cellulose Thimbles Type-MCT

Micro Separations Filter Carrier Unit

Micro Separations Cellulose Nitrate membrane Type-MCN

Micro Separations Cellulose Filter


FOR SAMPLE PREPARATION
Micro Separations Syringe Filters
Micro Separations syringe filters are ideal for preparing 1-100 ml samplers prior to chromatography or other
instrumental analyses. The Over molded Design for higher operating pressures and fast filtration.

Filter Type Available


 Nylon- Aqueous and organic solutions
 RC- Fast low and flow protein binding
 Hydrophilic PTFE – Aqueous and mild organic solutions
 Hydrophobic PTFE – Organic solvents
 PES- high flow rate, low extractable
 MCE- Biologically inert, widely used membranes in analytical and research applications

FEATURES:-
 GHPLC certified for Low Extractable
 IC Certified for Low Levels of inorganic Extractable(s)
 Color coding for Easy Identification

SPECIFICATION:-
MGD/X 13 mm MGD/X 25mm MGD/X 33MM
Housing Polypropylene Polypropylene Polypropylene
Filtration area 1.3cm² 4.6cm²
Maximum pressure 100 psi(6.9 bar) 75 psi(5.2 bar)
Volume holdup full 50 µl (approx.) 250 µl (approx.)
housing with air purge
Flow direction Flow should enter from the Flow should enter from the Flow should enter from
inlet inlet the inlet
Inlet connection Female luer lock Female luer lock Female luer lock
Outlet connection Male luer Male luer Male luer
Sterilization Autoclave at 121°C (131° C Autoclave at 121°C (131° Autoclave at 121°C (131°
Max) at 15 psi for 20 min C Max) at 15 psi for 20 C Max) at 15 psi for 20
min min
Glass Micro Fibre pre 100% borosilicate, MGF-1 100% borosilicate, MGF-1 100% borosilicate, MGF-
filtration media µm-0.7µm µm-0.7µm 1 µm-0.7µm
ORDERING INFORMATION:-
Catalogue Membrane Pore Catalogue Quantity/Pac Catalogue number
number size(µm) number k
Microsep-13mm syringe Microsep-25mm syringe filter-Non Microsep-33mm syringe
filter-Non sterile sterile filter- Non sterile
MPNN-13-02 Nylon 0.22µm MPNN-25-02 100 MPNN-33-02
MPNN-13-04 Nylon 0.45µm MPNN-25-04 100 MPNN-33-04
MPPV-13-02 PVDF 0.22µm MPPV-25-02 100 MPPV-33-02
MPPV-13-04 PVDF 0.45µm MPPV-25-04 100 MPPV-33-04
MPPT-13-02 PTFE 0.22µm MPPT-25-02 100 MPPT-33-02
MPPT-13-04 PTFE 0.45µm MPPT-25-04 100 MPPT-33-04
MPPE-13-02 PES 0.22µm MPPE-25-02 100 MPPE-33-02
MPPE-13-04 PES 0.45µm MPPE-25-04 100 MPPE-33-04
MPCA-13-02 CA 0.22µm MPCA-25-02 100 MPCA-33-02
MPCA-13-04 CA 0.45µm MPCA-25-04 100 MPCA-33-04
MGD/X Syringe Filters
The MGD/X range is specifically designed for high particulate loaded samples. Constructed of a pigment
–free polypropylene housing with a pre filtration stack of micro separations MGF (micro glass fibre media),
these filters eliminate sample contamination and allow you to filter even the most difficult samples with less
hand pressure.

APPLICATIONS:-
MGD/X Syringe Filers are ideal for heavily particulate laden sample found in:

 Dissolution testing, Concentration analyses


 Content uniformity, Routine sample Preparation

Typical data – MGD/X Syringe Filters


MGD/X 13 mm MGD/X 25mm MGD/X 33MM
Housing Polypropylene Polypropylene Polypropylene
Filtration area 1.3cm² 4.6cm²
Maximum pressure 100 psi(6.9 bar) 75 psi(5.2 bar)
Volume holdup full 50 µl (approx.) 250 µl (approx.)
housing with air purge
Flow direction Flow should enter from the Flow should enter from the Flow should enter from
inlet inlet the inlet
Inlet connection Female luer lock Female luer lock Female luer lock
Outlet connection Male luer Male luer Male luer
Sterilization Autoclave at 121°C (131° C Autoclave at 121°C (131° Autoclave at 121°C (131°
Max) at 15 psi for 20 min C Max) at 15 psi for 20 C Max) at 15 psi for 20
min min
Glass Micro Fibre pre 100% borosilicate, MGF-1 100% borosilicate, MGF-1 100% borosilicate, MGF-
filtration media µm-0.7µm µm-0.7µm 1 µm-0.7µm

Catalogue Membrane Pore Catalogue Quantity/Pack Catalogue number


number size(m) number
Microsep-13mm syringe filter- Microsep-25mm syringe filter-Non Microsep-33 mm syringe
Non sterile sterile filter- Non sterile

MGDNN-13-02 Nylon 0.2 MGDNN-25-02 100 MGDNN-33-02


MGDNN-13-04 Nylon 0.45 MGDNN-25-04 100 MGDNN-33-04
MGDPV-13-02 PVDF 0.2 MGDPV-25-02 100 MGDPV-33-02
MGDPV-13-04 PVDF 0.45 MGDPV-25-04 100 MGDPV-33-04
MGTPT-13-02 PTFE 0.2 MGTPT-25-02 100 MGTPT-33-02
MGTPT-13-04 PTFE 0.45 MGTPT-25-04 100 MGTPT-33-04
MGDPES-13-02 PES 0.2 MGDPES-25-02 100 MGDPES-33-02
MGDPES-13-04 PES 0.45 MGDPES-25-04 100 MGDPES-33-04
MGDCA-13-02 CA 0.2 MGDCA-25-02 100 MGDCA-33-02
MGDCA-13-04 CA 0.45 MGDCA-25-04 100 MGDCA-33-04
Nylon Membrane (MPNN)
Micro Separations membrane filters are recommended for particles removing filtration for water, aqueous
solutions and solvents for analytical determinations such as HPLC, as well as for the filtration of these liquids.

TYPICAL APPLICATIONS:-

 HPLC sample preparations


 Sterile filtration of aqueous and solvent solutions
 Clarification and particle removal

SPECIFICATIONS:-
Color White
Material Nylon
Reaction to water Hydrophilic
Pore size 0.2-5 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-
Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)

MPNN-02-13 13 100 Nylon 0.22µm


MPNN-02-25 25 100
MPNN-02-47 47 100
MPNN-02-90 90 100
MPNN-02-142 142 50
MPNN-02-293 293 50
MPNN-04-13 13 100 Nylon 0.45µm
MPNN-04-25 25 100
MPNN-04-47 47 100
MPNN-04-90 90 50
MPNN-04-142 142 50
MPNN-04-293 293 100
MPNN-08-13 13 100 Nylon 0.8µm
MPNN-08-25 25 100
MPNN-08-47 47 50
MPNN-08-90 90 50
MPNN-08-142 142 100
MPNN-08-293 293 100
MPNN-12-13 13 100 Nylon 1.2µm
MPNN-12-25 25 50
MPNN-12-47 47 50
MPNN-12-90 90 100
MPNN-12-142 142 100
MPNN-12-293 293 100
MPNN-50-13 13 50 Nylon 5.0µm
MPNN-50-25 25 50
MPNN-50-47 47 100
MPNN-50-90 90 100
MPNN-50-142 142 100
MPNN-50-293 293 50
Micro Separations Cellulose Nitrate Membrane (MCN)

Micro separations cellulose nitrate membranes are recommended for routine


laboratory application involving aqueous solutions.

Features and benefits

 Narrow pore sizes distribution for improved surface capture and analysis.
 Low level of extractable
 Gridded cellulose Nitrate Membrane recommended for sample preparation, Microbiological studies
 Particle counting for liquids and aerosols

Color White
Material Cellulose Nitrate
Reaction to water Hydrophilic
Pore size 0.2-5 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION
Catalogue Membrane Pore Diameter Solvent Quantity/Pack
number size(m) resistant

MCN-02-25 Cellulose nitrate 0.22 25 Medium 100


MCN-02-47 cellulose nitrate 0.22 47 Medium 100
MCN-02-90 cellulose nitrate 0.22 90 Medium 100
MCN-02-142 cellulose nitrate 0.22 142 Medium 50
MCN-02-293 cellulose nitrate 0.22 293 Medium 50
MCN-04-25 Cellulose nitrate 0.45 25 Medium 100
MGCN-04-47 Gridded cellulose 0.45 47 Medium 100
nitrate
MCN-04-47 cellulose nitrate 0.45 47 Medium 100
MCN-04-90 cellulose nitrate 0.45 90 Medium 100
MCN-04-142 cellulose nitrate 0.45 142 Medium 50
MCN-04-293 cellulose nitrate 0.45 293 Medium 50
MCN-08-142 cellulose nitrate 0.8 142 Medium 100
MCN-08-293 cellulose nitrate 0.8 293 Medium 100
MCA-Membrane

Micro Separations Cellulose Acetate membrane filter combines high flow rates with very low
absorption characteristics.

TYPICAL APPLICATIONS:-

 Sterile filtration of culture media


 Microbe-retentive, particle-removing, filtration of nutrient media, water and solutions
 Cell harvesting.

Color White
Material Cellulose Acetate
Reaction to water Hydrophilic
Pore size 0.2-5.4 µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION:-
Cat.no. Diameter Qty/pk (pcs) Material Pore Size µm
MCA-02-25 25 100 Cellulose Acetate, 0.22µm
MCA-02-47 47 100 white, plain
MCA-02-90 90 50
MCA-04-25 25 100 0.45µm
MCA-04-47 47 100
MCA-04-90 90 50
MCA-06-25 25 100 0.65µm
MCA-06-47 47 100
MCA-06-90 90 50
MCA-08-25 25 100 0.8µm
MCA-08-47 47 100
MCA-08-90 90 50
MCA-12-25 25 100 1.2µm
MCA-12-47 47 100
MCA-12-90 90 50
PES Membrane (MPPE)
This membrane has very low protein biding characteristics, high liquid flow rates and throughput (long life), and
low extractable. PES’s hydrophilic characteristics allow it to be used with both liquids and dry gases, makes it
suitable for a verity of environments.

TYPICAL APPLICATIONS:-

 HPLC sample preparations, Sterilizing Filtration


 Sterile filtration
 Clarification and particle removal

Color White
Material PES
Reaction to water Hydrophilic
Pore size 0.22-0.45µm
Diameter 13/25/47/90/142/250/293 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION:-

Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)

MPPE-02-13 13 100 PES 0.22


MPPE-02-25 25 100
MPPE-02-47 47 100
MPPE-02-90 90 50
MPPE-04-13 13 100 PES 0.45
MPPE-04-25 25 100
MPPE-04-47 47 100
MPPE-04-90 90 50
MCE Membrane
Micro Separations MCE (Mixed cellulose ester) membrane is biologically inert, it’s one of the most widely used
membranes in research applications, MCE membrane filters are characterized by a smoother and more uniform
surface than pure nitro cellulose filter, providing superior flow rates. Withstand autoclaving temperatures up to
130oC without adversely affecting bubble point, flow rate or microbiological recovery.

TYPICAL APPLICATIONS:-

 Widely used membrane in analytical and research applications


 Sterilizing biological fluids
 Microbiological testing

SPECIFICATIONS:-
Color white
Material Mixed Cellulose Acetate
Reaction to water Hydrophilic
Pore size 0.22-1.2 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100 pcs

ORDERING INFORMATION:-
Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)

MCE-02-13 13 100 Mixed Cellulose Ester 0.22


MCE-02-25 25 100
MCE-02-47 47 100
MCE-02-90 90 50
MCE-04-13 13 100 Mixed Cellulose Ester 0.45
MCE-04-25 25 100
MCE-04-47 47 100
MCE-04-90 90 50
MCE-06-13 13 100 Mixed Cellulose Ester 0.65
MCE-06-25 25 100
MCE-06-47 47 100
MCE-06-90 90 50
MCE-08-13 13 100 Mixed Cellulose Ester 0.8
MCE-08-25 25 100
MCE-08-47 47 100
MCE-08-90 90 50
MCE-12-13 13 100 Mixed Cellulose Ester 1.2
MCE-12-25 25 100
MCE-12-47 47 100
MCE-12-90 90 50
Hydrophobic PTFE Membrane (MPTF)
Micro Separations hydrophobic PTFE membrane is made from pure PTFE membrane bounded to a
polypropylene support. The extreme chemical compatibility (pH 1-14) makes them very useful for the filtration
of solvents and acids or other aggressive chemicals, for which other membrane filter types are unsuitable. Due
to their hydrophobic characteristics, they must be pre-wet with a solvent such as ethanol or methanol before the
filtration of aqueous solutions.

TYPICAL APPLICATIONS:-

 Ideal for HPLC and organic solvents


 Air and gas filtration
 Aerosol sampling

SPECIFICATIONS:-
Color White
Material PTFE
Reaction to water Hydrophobic
Pore size 0.1-5 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs
ORDERING INFORMATION:-

Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)

MPTF-01-13 13 100 Hydrophobic PTFE, 0.1


MPTF-01-25 25 100 PP supported
MPTF-01-47 47 100
MPTF-01-90 90 50
MPTF-01-142 142 50
MPTF-02-13 13 100 Hydrophobic PTFE, 0.22
MPTF-02-25 25 100 PP supported
MPTF-02-47 47 100
MPTF-02-90 90 50
MPTF-02-142 142 50
MPTF-04-13 13 100 Hydrophobic PTFE, 0.45
MPTF-04-25 25 100 PP supported
MPTF-04-47 47 100
MPTF-04-90 90 50
MPTF-04-142 142 50
MPTF-12-13 13 100 Hydrophobic PTFE, 1.2
MPTF-12-25 25 100 PP supported
MPTF-12-47 47 100
MPTF-12-90 90 50
MPTF-12-142 142 50
MPTF-30-13 13 100 Hydrophobic PTFE, 3.0
MPTF-30-25 25 100 PP supported
MPTF-30-47 47 100
MPTF-30-90 90 50
MPTF-30-142 142 50
Hydrophilic PTFE Membrane (MPTF)
Micro Separations hydrophilic PTFE (polytetrafluorethylene) membrane filters has a durable wide operating
temperature range and resistance to the destructive effects of many chemicals. It can be used to filter aqueous
fluids without prior wetting.

SPECIFICATIONS:-
Color White
Material PTFE
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142
mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION:-

Cat. No. Diameter Qty/pk(pcs) Material Pore


(mm) Size(µm)

MPTF-02-13 13 100 Hydrophilic 0.22


MPTF-02-13 25 100 PTFE,
MPTF-02-13 47 100 supported
MPTF-04-13 13 100 Hydrophilic 0.45
MPTF-04-13 25 100 PTFE,
MPTF-04-13 47 100 supported
Hydrophilic Pvdf Membrane (MPPV)
Micro Separations hydrophilic PVDF (Polyvinylidene Difluoride) membrane filter has excellent water wettability,
providing high flow rate. PVDF membrane are naturally hydrophobic but are modified to a hydrophilic nature.
Useful for a wide range of applications, both aqueous and non-aggressive solvents-based. These membranes are
typically low protein binding and are frequently used for sterilizing filtration.

SPECIFICATIONS :-
Color white
Material PVDF
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142 MM
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION:-

Cat. No. Diameter Qty/pk(pcs) Material Pore


(mm) Size(µm)

MPPV-02-13 13 100 Hydrophilic 0.22


MPPV-02-25 25 100 PVDF
MPPV-02-47 47 100
MPPV-02-90 90 50
MPPV-04-13 13 100 Hydrophilic 0.45
MPPV-04-25 25 100 PVDF
MPPV-04-47 47 100
MP PV-04-90 90 50
PP Membrane FILTER (MPPP)
This filter is a preferred choice for HPLC applications. This plastic polymer has very good resistance to a broad
range of chemicals even at high temperature. Adaptable materials for applications ranging from air filtration.

TYPICAL APPLICATIONS:-

 Aqueous and organic solvent filtration


 Depth filtration
 Sterilize gases, traps aqueous aerosols
 Air and gas venting

Color White
Material PP
Reaction to water Hydrophilic
Pore size 0.22-0.45 µm
Diameter 13/25/47/90/142 mm
Package 13mm, 100 pcs
25mm, 100 pcs
47mm, 100pcs

ORDERING INFORMATION:-

Cat. No. Diameter (mm) Qty/pk(pcs) Material Pore Size(µm)

MPPP-02-13 13 100 PP 0.22


MPPP-02-25 25 100
MPPP-02-47 47 100
MPPP-02-90 90 50
MPPP-04-13 13 100 PP 0.45
MPPP-04-25 25 100
MPPP-04-47 47 100
MPPP-04-90 90 50
MPPP-12-13 13 100 PP 1.2
MPPP-12-25 25 100
MPPP-12-47 47 100
MPPP-12-90 90 50
MPPP-25-13 13 100 PP 2.5
MPPP-25-25 25 100
MPPP-25-47 47 100
MPPP-25-90 90 50
Glass Fiber Filter (MGF)
These filters without binder resin retain their structural integrity without weight loss when heated up to 500 o C
and can therefore be used in gravimetric analysis as well as for the filtrating extremely fine precipitates such as
protein, nucleic acids or serum precipitates.

SPECIFICATIONS:-
Type- MGF/4- Micro Glass fiber Filter
MGF/5
Thickness 0.45 mm
Weight 75 gm2
Maximum service 500oC
temperature
Steam Autoclave Yes

ORDERING INFORMATION:-
Cat. No. Pre-filter Quantity Diameter Solvent Pore
pack resistance Size(µm)

MGF/4- Micro Glass Fiber 50 47 Wide 1.5


47 Filter

MGF/4- Micro Glass Fiber 50 70 Wide 1.5


70 Filter
MGF/4-90 Micro Glass Fiber 50 90 Wide 1.5
Filter
MGF/4- Micro Glass Fiber 50 142 Wide 1.5
142 Filter
MGF/4- Micro Glass Fiber 50 293 Wide 1.5
293 Filter
MGF/5-47 Micro Glass Fiber 50 47 Wide 2.0
Filter
MGF/5-70 Micro Glass Fiber 50 70 Wide 2.0
Filter
MGF/5-90 Micro Glass Fiber 50 90 Wide 2.0
Filter
MGF/5- Micro Glass Fiber 50 142 Wide 2.0
142 Filter
MGF/5- Micro Glass Fiber 50 293 Wide 2.0
293 Filter
Capsule Filter
Our capsule filters are available in different sizes with effect filtration surface areas ranging from 150 to 1500
cm2. Capsules are available with membranes such as PES, nylon PTFE PVDF and non-woven polypropylene and
glass fiber depth media. The capsules are available with a variety of end fittings such as stepped barbs, tri-clamp
(sanitary) and NPT connections. Sterile and non-sterile options are also available.

FEATURES:-
 100% integrity tested during manufacturing
 Nylon membrane capsule is recommended for filtering aqueous solutions
 Dual layer PES membrane capsules filters provide efficient for critical aqueous solutions
 Hydrophobic PTFE membrane capsule filters are designed for use with organic solvents and chemically
aggressive solutions
 Polypropylene and Glass Fiber filter capsules are usually used as pre-filters
 Manufactured in clean room facilities under ISO Quality System.

FOR LAB WATER PURIFICATION


Point-of-use Capsule Filter
Micro Separations capsule filter is specially is used for the ultrapure laboratory water. These capsule filter with
PES membrane and positively charged Nylon66.

FEATURES:-
 Low hold up volumes and extractable
 Materials are in compliance with FDA-
 Manufactured in class 10,000 clean room which is ISO certified

SPECIFICATIONS:-
1. Filter media available – PES/Nylon
2. Housing core and support Material- Polypropylene
3. Sealing technology - Thermal bonding
4. Filling Bell - Polycarbonate
5. Pore size Available – 0.1/0.2 µm
6. Normal Dimensions – housing length (without filling bell)93/122mm(without vent) 45 mm
7. Inlet – 1/4" NPT
8. Outlet – ¼ to 3/8” Stepped Hose Barb with filling bell
9. Max operating temp- 60oC @ 2.1 bar
10. Max operating press- 4.1 bar@ambient temp
11. Endotoxin levels - <0.25 EU/ml using Limulus Amoebocyte Lysate LAL test
12. Biological safety – Material pass USP class VI
13. Sterilization – pre sterilized available, non-sterile can be autoclave at 121oC for 30min
14. Package – individual poly-bag wrapped , 1 pc per pack.
MICRO-BIOLOGY
Micro Separations® Membrane Filter (MGCE/MGCN)
Micro Separations Sterile individually packed gridded membrane filters are widely used in the food, beverage,
pharmaceutical industries for microbiology analysis of water and other liquids.

FEATURES:-
 Sterile individually packed
 A range of membrane pore sizes are available to meet wide variety of applications
 Consistent performance
 Lot traceability

SPECIFICATIONS:-
Membrane material Mixed cellulose Ester or Cellulose
Nitrate
Filter Diameter 47 mm
Filter Surface Gridded / Plain
Filter Color White
Pore Size 0.22/0.45/0.8 µm

ORDERING INFORMATION:-
Cat. No. Color Pore size Diameter Grid/ plain Membrane Packing
MGCE-02-47 WHITE 0.22 µm 47 mm Gridded Cellulose Esters 100
MGCE-04-47 0.45µm 47 mm Cellulose Esters
MGCE-08-47 0.8 µm 47 mm Cellulose Esters
MGCN-02-47 WHITE 0.22 µm 47 mm Gridded Cellulose Nitrate 100
MGCN-04-47 0.45µm 47 mm Cellulose nitrate
MGCN-08-47 0.8 µm 47 mm Cellulose nitrate
Micro Funnel Unit
The micro-fit unit is a disposable filtration device for bio-burden testing of liquid samples including water,
process samples or final products. It is designed for optimizing and securing the laboratory work.

Applications:-
 Ideal for quality control analysis of aqueous fluids used in pharmaceutical production, water and food &
beverage applications
 Disposable filter funnels eliminate the possibility of sample cross contamination
 Reduce contamination and labor work
 Ready to use pre sterilized

Key features:-
 Universall
 y adaptable design fits directly on most filter manifolds
 Validated ink grids for no inhibitory effect on microbial recovery and no inference with colony counting

SPECIFICATIONS:-
Material of construction Cellulose Esters/ Cellulose Nitrate
Thickness 150µm
Pore size 0.2µm-0.45µm
Water flow rate ≥200ml/min@250mm vacuum
Retention efficiency LRV>7for S. maracseins (atec14756 pirem2)
Variants With pad/ without pad
Filtration surface 12.56cm2
Sterilization method ETO/Gamma
Maximum operating temp 45oC

ORDERING INFORMATION:-
MICRO FUNNEL WITH PAD
Cat. No. Description Pore size Quantity
MFGCNP-02-47(S) Micro-fit filtration unit, white gridded CN 0.22 25pices/pkt
membrane,0.22/100ml
MFGCNP-04-47(S) Micro-fit filtration unit, white gridded CN 0.45 25pices/pkt
membrane,0.45/100ml
MFGMCEP-02- Micro-fit filtration unit, white gridded MCE 0.22 25pices/pkt
47(S) membrane,0.22/100ml
MFGMCEP-04- Micro-fit filtration unit, white gridded MCE 0.45 25pices/pkt
47(S) membrane,0.45/100ml

MICRO FUNNEL WITHOUT PAD


Cat. No. Description Pore size Quantity
MFGCN-02-47(S) Micro-fit filtration unit, white gridded CN 0.22 25pices/pkt
membrane,0.22/100ml
MFGCN-04-47(S) Micro-fit filtration unit, white gridded CN 0.45 25pices/pkt
membrane,0.45/100ml
MFGMCE-02- Micro-fit filtration unit, white gridded MCE 0.22 25pices/pkt
47(S) membrane,0.22/100ml
MFGMCE-04- Micro-fit filtration unit, white gridded MCE 0.45 25pices/pkt
47(S) membrane,0.45/100ml
Micro-fit® Manifold
Micro-fit manifold works with optimal hardware and consumables especially suitable for Ascle U filtration funnel
and Ascle V filtration unit.

It has the same features with traditional manifold besides it is more flexible and has light structure.

FEATURES:-
Whole equipment body is designed with stainless steel, surface is minor finished and is easy to clean and sterilize.

Triplet filtering head design can be simultaneously suction filtration to improve work efficiency.

Filtering head can quickly sterilize via flame for continuous lab operation.

Filtering head can be easily dismounting and mounting and individual do moist heat sterilization

Multiple filtering heads are available for two kinds of two kinds of membrane specification at 47mm and 50mm

STERILIZATION:-
 By autoclaving (max, 134oC)
 By dry heat sterilization (max, 180oC)
 By flaming

ORDERING INFORMATION:-
Cat. No. Applicable Dimension Weight
membrane
diameter
Micro-fit SS M301SS 47/50 mm 43.5x10.3x12 cm 1.5 kg
Manifold, 3-place

Micro-Sep Air Vent Filter


Micro separations filter is self-contained, compact, high flow, liquid rated, sterilizing-grade devices that meets
the critical demands of the pharmaceuticals, biotechnology and related industries. The product is designed and
purposes build for small scale critical air and gas filtration applications.

Rugged polypropylene housings have broad chemical compatibility, hydrophobic membranes, including PTFE,
PVDF, fiber glass laminated, provide high efficiency removal of airborne bacteria and particulate under dry or
moist conditions.

These devices act as barriers on air lines. They prevent the entry of water and aerosols into sensitive equipment
and also protect the lab environment from aerosolized pathogens. Vent filters can also enable air to enter and
exit vessels such as bioreactors, while maintaining the sterility of the interior environment.

FEATURES AND BENEFITS

 Ideal for small volume venting, solvent and gas filtration.


 Broad chemical compatibility.
 Economical; available in bulk packaging.
 100% integrity tested during manufacture.
 Individual serialized for optimum traceability critical applications.
SPECIFICATIONS.

Material of Construction Filter Membrane PTFE/PVDF/PP/Fiberglass

Downstream support PP(Polypropylene)


Capsule Housing PP
Sealing Method Thermal Bonding
Filtration Ratings 0.1,0.2,0.45,0.8,1,3,5µm
Inlet and Outlet Stepped hose barbs, ¼”- 1/2”(6.4-12.7)mm
Integrity Testing Minimum Bubble Point(95% PTFE,0.2µm 1200 mbar
Ethanol) PES, 0.2µm 1200 mbar
Bacterial Retention >10^7 cfu/cm² retention of Brevundimonas diminuta per ASTM F838
Sterilization Autoclave: 121°C to 135°C (5 to 30psi, 1 o 2 bar), 30 min, ≥3 cycles.
Gamma Irradiation: 25 to 40 kGy once.
Do not autoclave irradiated capsules.
Capsules must not be in-line steam sterilized.
Maximum Operating Pressures 4.1 bar (410 kPa, 60Psi) at
ambient temperature.
Effective Filtration Area 19.6cm²

Application:-
 Venting receiving vessels
 Isolation or environmental chambers
 Bioreactors
 Fermentation tanks
 Carboys, and other small containers
 Use in-line for low-pressure sterile air/gas delivery to instruments and culture vessels
 Bio-isolation of a vacuum source
 Flushing instruments and cleaning parts.

Order Information:-

FDF5

Code Membrane Code Rating Code Housing Code Pre-filter


P PP 010 0.1 P PP -- none
E PES 020 0.2 H HDPE P PP
F PTFE 045 0.45 G Fiberglass
V PVDF 080 0.8
G Fiberglass 100 1.0
300 3.0
500 5.0
Ultrafiltration Membrane
BLOTTING MEMBRANE
Dot blotting is a method of applying directly onto membrane. A dissolved sample is pulled through the membrane
by either applying a vacuum, absorption or intrusion, proteins bind to the membrane and the other sample
components pass through. The proteins on the membrane are then available for analysis.

PVDF blotting membrane / Nylon blotting membrane

PVDF blotting membrane


Description
Micro Separations PVDF blotting membrane is ideal for western blotting, protein sequencing and protein binding
assays.

FEATURES:-
 Strong protein adsorption capability, stronger signal, low background;
 High mechanical strength good ductility;
 Broad chemical compatibility.

ORDERING INFORMATION:-
Cat. No. Size Pore size µm Packaging
MPV-02-21 7x8.4 cm sheet 0.2 PVDF
MPV-02-22 15x15 cm sheet
MPV-02-33 20x20 cm sheet
MPV-02-24 26cm x 3.3 m roll
MPV-02-25 30cm x 3m roll
MPV-04-51 7x8.4 cm sheet 0.45

MPV-04-52 15x15 cm sheet


MPV-04-53 20x20 cm sheet
MPV-04-54 26cm x 3.3 m roll
MPV-04-55 30cm x 3m roll
Disposable Vent Filter
FEATURES AND BENEFITS:-
 Exceptionally high low rate with low pressure drop
 100% integrity tested to provide a high level of confidence
 Can be sterilized by gamma irradiation or autoclaving

APPLICATION:-
 Venting bioreactors
 Fermentation tanks
 Culture vessels
 Carboys
 Filling machines
 Autoclaves
 Transfer vessels

Filter Hydrophobic PTFE on a Hydrophobic PTFE Hydrophobic PTFE Hydrophobic PTFE


Media PET support on PET support on a PET support on a PET support

Pore size 0.2µm 0.2µm 0.2µm 0.2µm


Housing Gamma Stable PP Gamma Stable PP Gamma Stable PP Gamma Stable PP
Effective 0.72/3.4/4.5 cm2 13.8cm2 20.0cm2 20.0cm2
Filtration
Area
Overall 19.0/22.5/26.1mm 47 mm 69.5mm 83.5mm
length
Diameter 18/30/350mm 56mm 64mm 73mm
Inlet/Outle Inlet-female luer lock 1/4”-3/8’’ hose barb 1/4” - 1/2” hose barb 1/4 ”- 1/2” hose barb
t Outlet-male luer slip
connection
s
Max. 6.0bar(87psi)@20oC 2.4bar(35psi)@20oC 4.2bar(61psi)@20oC 2.4bar(35psi)@20oC
operation
Pressure

Typical Air 13mm:0.5L/min@0.2bar(3p 6.3L/min@0.2bar(3ps 9.6L/min@0.2bar(3ps 9.0L/min@0.2bar(3ps


Flow Rate si) i) i) i)
(20oC) 25mm:2.1L/min@0.2bar(3p
si)
33mm:2.9L/min@0.2bar(3p
si)
Bubble ≥1.1bar(60%IPA) ≥1.1bar(60%IPA) ≥1.1bar(60%IPA) ≥1.1bar(60%IPA)
Point
Sterilizatio Gamma irradiation Gamma irradiation Gamma irradiation Gamma irradiation
n 25kGy recommended 25kGy recommended 25kGy recommended 25kGy recommended
Gamma irradiation Gamma irradiation Gamma irradiation
50kGy maximum 50kGy maximum 50kGy maximum
Biological Meets USP biological reactivity test in vivo for class VI-121oC Plastics.
safety
ORDERING INFORMATION:-
Cat. No. Material Pore size Sterility
SMF13PT0022-GM PTFE 0.2 Gamma-irradiated
SMF25PT0022-GM Gamma-irradiated
SMF33PT0022-GM Gamma-irradiated
SS47DISC-GM-PTFE0020L Gamma-irradiated
SS47DISC-PTFE0020L Autoclaving
64DISC-GM-PTFE0020L Gamma-irradiated
64DISC-PTFE0020L Autoclaving
AV50-GM-PTFE0020L Gamma-irradiated
AV50-PTFE0020L Autoclaving
Micro Separations PTFE Filter Type-PMTF2.5
A new high purity chemically resistance thin PTFE Membrane in a sequentially numbered chemically resistant
Poly Propylene supporting ring ideal for pm2.5 ambient air monitoring and sampling in aggressive environment.

FEATURES AND BENEFITS

Convenient
Each filter is individually numbered for easy sample tracking.
Each box of 50 filters is sequentially leveled for easy control.

Precise
Low tare mass provided for accurate gravy metric determination. The unique thermally stable design
eliminates curling, keep the membrane flat, and make fitter robot friendly.

Clean
Manufacture under clean room conditions, these chemically resistance, low chemical background filter permit
sensitive interference free determinations.

SPECIFICATIONS:-

Property Test Method Unit Of Value Range


Measure
Filter Media n/a n/a PTFE Teflon n/a
Filter Thickness Micrometer µm 40 ±10
Filter Diameter Micrometer Mm 46.2 ±0.25
Filter pore size ASTM F316-94 µm 2 Maximum
Supporting ring media n/a n/a PP PMP or Equivalent
Total support ring Micrometer Mm 0.365 ±0.055
thickness
Support ring width Micrometer Mm 3.68 +0.00,-0.51
Particle ASTM D 2986-95a % 99.7 Min
retention(0.3µm)
Pressure ASTM D 2986- 25a cmH2O 30 Max
drop(0.3µm)@16.67
ltr/min
Alkalinity EPA/600-R- µeg/g of filter 25 Max
94/038b, Sec.2.12
Weight loss As Above µg ˂20 Max
Loose particles As Above µg ˂ 20 Max
Moisture pickup As Above µg ˂ 10 Max
APPLICATION:-
For air monitoring and sampling in aggressive environment
Support Membrane offer increased durability for hostile testing environment or acid aerosol monitoring.

ORDERING INFORMATION:-

PM2.5 Air Monitoring


Catalogue no. Product description Diameter (mm) Quantity/pack
PMTF2.5-46.2 PTFE Membrane W/support ring 46.2 50
sequentially numbered
Micro Separations Micro Glass Fiber Filter Type-MGF/1
Micro separations high purity micro glass fiber filters is manufactured from 100% borosilicate glass & widely
used for air pollution monitoring.

FEATURES AND BENEFITS:-


 Chemically & Biologically Inert
 High Temperature Resistant (500oC)
 High flow rate & High dirt holding capacity

SPECIFICATIONS:-
Properties Unit of Measure Value Variations
Filter Media n/a Micro Glass Fiber n/a
Thickness Mm 0.28 ± 15
Basic weight gm2 53 Maximum
Dimensions inches 8”x10” ± 1/16
203mm x 254mm
Pore size(particle Retention µm 1.6 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.95 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 4.3 Max
Initial Filtration speed (secs/100ml)Herzberg 62 Max
Tensile Strength MD N/15mm 5.5 Min.
Wet Burst Psi 0.3 -
Binder - No Binding -
Loading Capacity - High -
Recommended for Gravimetric determination of air born particle, absorption method for air pollution
monitoring Equivalent to WHATMAN grade-GF/A

ORDERING INFORMATION
Diameter Catalog no. Quantity packs
Grade MGF/1
Filter Circle
25mm MGF/1-25 All item are 100
37mm MGF/1-37 pcs per pack
47mm MGF/1-47
70mm MGF/1-70
82mm MGF/1-82
90mm MGF/1-90
110mm MGF/1-110
125mm MGF/1-125
Filter Sheet
203mmX MGF/1-203254 100 Sheets/Pkt
254mm
Micro Separations Micro Glass Fiber Filter Type-MGF/2000
Micro separations high purity Micro Glass Fiber filters are manufactured from 100% borosilicate glass and
produced especially for use in high volume PM-10 air sampling equipment that collect atmospheric particulates
and aerosols. It’s enabling detailed chemical analysis of trace pollutants to take place with the minimum of
interference or background.

FEATURES AND BENEFITS

 Chemical & biological inert


 High temperature resistance 500oC
 High flow rate & High dirt holding capacity

SPECIFICATIONS:-

Properties Unit of Measure Value Variations


Filter Media n/a Micro Glass Fiber n/a
Thickness Mm 0.28 ± 15
Basic weight gm2 85 Maximum
Dimensions inches 8”x10” ± 1/16
203mm x 254mm
Pore size(particle Retention µm 1.6 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.93 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 4.3 Max
Initial Filtration speed (secs/100ml)Herzberg 62 Max
Tensile Strength MD N/15mm 5.5 Min.
Brittleness Test of fiber filter No crack larger than 1 Max
inch
Binder - No Binding -
Loading Capacity - High -
MFGF2000 Micro Glass Fiber Filter used for analysis of trace pollutant in atmosphere.
Equivalent to WHATMAN Grade-EPM2000
Absorption method for air pollution monitoring

ORDERING INFORMATION:-
Diameter Catalog no Quantity packs
Filter circle
47 mm MGF/2000-47 100 pcs/pack
Filter sheets
203 mm x254 mm MGF/2000-203254 100 sheets/pkt
Micro Separations Micro Glass Fiber Filter Type-MGF/3
Micro separations high purity Micro Glass Fiber filters are manufactured from 100% borosilicate glass and
produced especially for use in high volume PM-10 air sampling equipment that collect atmospheric particulates
and aerosols. It’s enabling detailed chemical analysis of trace pollutants to take place with the minimum of
interference or background.

FEATURES AND BENEFITS:-

 Chemical & biological inert


 High temperature resistance 500 oC
 High flow rate & High dirt holding capacity

SPECIFICATIONS:-

Properties Unit of Measure Value Variations


Filter Media n/a Micro Glass Fiber n/a
Thickness Mm 0.26 ± 15
Basic weight gm2 53 Maximum
Pore size(particle Retention µm 1.2 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.98 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 4.3 Max
Initial Filtration speed (secs/100ml)Herzberg 100 Max
Tensile Strength MD N/15mm 5.5 Min.
Wet Burst Psi 0.29 Max
Binder - No Binding -
Loading Capacity - High -

99% particles retention rating


Recommended for TSS analysis for industrial and natural waste water. Equivalent to WHATMAN grade-934AH

ORDERING INFORMATION:-

Diameter Catalog no. Quantity packs


Grade MGF/3
Filter Circle
25mm MGF/3-25 All item are 100
37mm MGF/3-37 pcs per pack
47mm MGF/3-47
70mm MGF/3-70
82mm MGF/3-82
90mm MGF/3-90
110mm MGF/3-110
125mm MGF/3-125
Filter Sheet
203mmX MGF/3-203254 100 Sheets/Pkt
254mm
Micro Separations Micro Glass Fiber Filter Type-MGF/934AH
Micro separations high purity Micro Glass Fiber filters are manufactured from 100% borosilicate glass smooth
surface used in standard methods for determining total suspended solids in water, removal of turbidity, and
filtration of bacterial cultures.

FEATURES AND BENEFITS

 Chemical & biological inert


 High temperature resistance 500 oC

SPECIFICATIONS:-

Properties Unit of Measure Value Variations


Filter Media n/a Micro Glass Fiber n/a
Thickness Mm 0.43 ± 15
Basic weight gm2 64 Maximum
Pore size(particle Retention µm 1.5 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.97 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 3.7 Max
Tensile Strength MD N/15mm 4.1 Min.
Wet Burst Psi 0.5 Max
Binder - No Binding -
Loading Capacity - High -
99% particle Retention Rating
Recommended for water pollution monitoring, cell harvesting, Liquid scintillation counting, and air pollution
monitoring.
Equivalent to WHATMAN grade-934AH

ORDERING INFORMATION:-

Diameter Catalog no. Quantity


packs
Grade
MGF/934AH
Filter Circle
25mm MGF/934AH-25 All item are
37mm MGF/934AH-37 100 pcs per
47mm MGF/934AH-47 pack
70mm MGF/934AH-70
82mm MGF/934AH-82
90mm MGF/934AH-90
110mm MGF/934AH-110

125mm MGF/934AH-125
Micro Separations Quartz Micro Fiber Filter Type-QMF/1
Micro separations high purity Quartz Micro Fiber filter is manufactured from 100% micro-quartz fiber and
widely used for air sampling in acidic gasses, stacks, flues and aerosols particularly at high temperature up to
900oC.

FEATURES AND BENEFITS

 Chemical & biological inert


 High Temperature resistance (900oC)
 Binder free low heavy metal content

SPECIFICATIONS:-

Properties Unit of Measure Value Variations


Filter Media n/a Quartz Micro Fiber n/a
Thickness Mm 0.45 ± 15
Basic weight gm2 85 Maximum
Dimensions inches 8”x10” ± 1/16
203mm x 254mm
Pore size(particle Retention µm 1.6 Mean
liquid(µm)
D.O.P Retention@32 Imp/100 % 99.95 Min.
sq.cm(0.3µm particle)
Air flow rate s/100ml/in2 6.4 Max
Initial Filtration speed (secs/100ml)Herzberg 62 Max
Tensile Strength MD N/15mm 3.5 Min.
Wet Burst Psi 1.5 -
Binder - No Binding -
Loading Capacity - High -
99% Particle Retention Rating
Recommended for analysis of acidic gases (except HF), Control of suspended lead particle in air
Equivalent to WHATMAN grade-QM/A

ORDERING INFORMATION:-

Diameter Catalog no. Quantity packs


Grade QMF/1
Filter Circle
25mm QMF/1-25 All item are 100
37mm QMF/1-37 pcs per pack
47mm QMF/1-47
70mm QMF/1-70
82mm QMF/1-82
90mm QMF/1-90
110mm QMF/1-110
125mm QMF/1-125
Filter Sheet
203mmX QMF/1-203254 100 Sheets/Pkt
254mm
Micro Separations Micro Glass Fiber Tape Roll Type-MGFBM (BAM TAPE
ROLE)
Micro Separations high purity micro glass fiber BAM Tape roll manufactured with 100% borosilicate glass fiber
and organic binder. With extreme mechanical stability and temperature resistance up to filter units and air
analyzers.

FEATURES AND BENEFITS

 Extreme Mechanic stability


 Used as a weighing aid for infrared weighing
 Used up to 180oC

SPECIFICATIONS
Properties Unit of measurement values Variation
Filter Media Glass Micro Fiber - Max
Basic weight g/m2 49 Max
Thickness mm 0.14
Pressure drop (Kpa) 0.3µm @5.3cm/sec 20 Max
Efficiency (%) 0.3µm @5.3cm/sec 99.9 Max
MD Tensile N/M 780 Max
Binder - Yes
Air Flow Rate s/100ml/1.56cm2 12 Max
Recommended for Beta attenuation monitor for PM2.5 & PM 10 Monitoring

ORDERING INFORMATION:-

Catalogue Product Size(W X meter) Quantity


Number Description
MGFBM3021 Glass Fiber Roll 30mm x 21mtr 01 nos
MGFBM4042 Glass Fiber Roll 40mm x 42mtr 01 nos
Micro Separations Micro Glass Fiber Thimbles Type-MGFT
Micro separations high purity Micro Glass Fiber Thimbles manufactured from 100% borosilicate glass and
widely used for pollution monitoring.

FEATURES AND BENEFITS:-

 Chemically & Biologically Inert


 High temperature resistant (500oC)
 Available in arrange of size and wall thickness to suit your application

SPECIFICATIONS:-

Properties Unit of Measure Value Variations


Filter Media n/a Micro Glass Fiber n/a
Thickness mm 1.5-2.0 -
Particle retention for single µm 1.6µm -
Thickness
Particle retention for double µm 0.8µm Min.
thicknesss
Maximum operating Temperature Centigrade (oC) 500oC Max
Binder - No Binding -
Retention Efficiency % 99.95 Max

Thickness of Thimbles used as per Application


Smoke Stack gas monitoring

ORDERING INFORMATION:-

Nominal Internal Diameter X Catalogue no Quantity/packs


External Length (mm) Grade MGFT 25 pcs/pack
19mmx90mm MGFT1990
Micro Separations Micro Cellulose Thimbles Type-MCT
Micro Separations Cellulose Extraction Thimbles have a reputation for purity and consistence high quality.
Cellulose extraction thimbles are produced high quality cellulose cotton linter which has excellent mechanical
strength and retentive.

FEATURE AND BENEFITS:-

 Designs to fit most commercial availability Soxhelet extractors


 Temperature resistant (150oC)
 Available in range of size and wall thickness to suit your application

SPECIFICATIONS
Properties Unit of Measure Value Variations
Filter Media n/a Cellulose n/a
Thickness mm Single or double -
Particle retention for single µm 10µm -
Thickness
Particle retention for double µm 6µm Min.
thicknesss
Maximum operating Temperature Centigrade (oC) 105oC Max
Binder - No Binding -
Thickness of Thimbles used as per Application Smoke Stack gas monitoring

ORDERING INFORMATION

Nominal internal Catalogue Quantity/packs


diameter X External Number
length (mm)
Grade MCT 25/packs
19mm x90mm MCT1990 25/packs
22mm x80mm MCT2280 25/packs
25mm x80mm MCT2580 25/packs
25mm x100mm MCT25100 25/packs
28mm x80mm MCT2880 25/packs
28mm x100mm MCT28100 25/packs
30mm x80mm MCT3080 25/packs
30mm x100mm MCT30100 25/packs
33mm x80mm MCT3380 25/packs
33mm x100mm MCT33100 25/packs
Micro Separations Filter Carrier Unit
FEATURES AND BENEFITS

 Material of construction- polystyrene


 Rectangular base fits most microscope stages
 Inner cover ring for air tight securing of sample does not interfere with viewing
 Frosted Area on base permits identification of the sample with pencil or marker
 Convenient (slide pack) box simplifies collecting sample in the field.

APPLICATIONS:-

 Protect the integrity of sample membrane during microscopic examination


 Store and protect membrane filters for reference.

ORDERING INFORMATION:-

Catalogue no Description Quantity/pack


MS-FC-47 Filter Carrier 100
Micro Separations Cellulose Nitrate membrane Type-MCN
Micro Separations cellulose nitrate membranes are recommended for routine laboratory application involving
aqueous solutions. The membrane exhibit very narrow pore size distribution and have low level of extractable.
The membranes are strong and flexible and can with stand handling and autoclaving procedure without loss of
integrity.

FEATURES AND BENEFITS

 Narrow pore size distribution for improved surface capture and analysis
 Low level of extractable to ensure sample integrity

SPECIFICATIONS:-

Material Cellulose Nitrate


Thickness 125mm
Burst Strength >2psi
Weight 3.6-5.5mg/cm2
Maximum service 80oC
temperature
Steam Autoclave YES

Recommended for sample preparation, Microbiological Studies

ORDERING INFORMATION:-
Catalogue no Membrane Pore size (µm) Diameter (mm) Solvent Quantity /pack
resistant
MCN-0.2 Cellulose Nitrate 0.2 47 medium 100
MCN-0.45 Cellulose Nitrate 0.45 47 Medium 100
Micro Separations Cellulose Filter
Qualitative Filter
These filters are used in qualitative technique to determine and identify material.

Grade-MS-1
11µm – a medium retention and flow rate filter for routine application- including soil analysis and seed testing
procedure, food industry testing, air pollution monitoring and gas detection.

Quantitative Filter
Micro Separations quantitative filters are designed for gravimetric analysis and preparation of samples of
instruments analysis.

Grade-MS-40
8µm general purpose ashless filter with medium speed and particle retention. Application includes gravimetric
analysis, the filtration of solutions prior to atomic absorption spectrophotometry and in air pollution monitory.

Grade-MS-41
20-25µm- the fastest ashless filter is recommended for analytical procedures involving large particles or
gelatinous precipitates as such iron or aluminum hydroxides. Also used in quantitative air pollution analysis for
determining gaseous compound at high flow rates.

Grade-MS-42

2.5µm- filter with the finest particle retention of cellulose filters. Typically analytical precipitates include
barium sulphate, metastenic acid and finely precipitated calcium carbonate.

SPECIFICATIONS:-
Grade Particle Air flow rate Ash Thickness Basis Wet Dry Tensile MD
retention s/100ml/in2 (%) (µm) weight burst burst dry
liquid g/m2 (psi) (psi) (N/15mm)
(µm)
Qualitative
MS-1 11 10.5 0.06 180 88 0.3 16 39.1
Ashless Quantitative
MS-40 8 19.3 .007 210 92 0.5 16 46.7
MS-41 20 3.4 .007 215 84 0.3 10 27.2
MS-42 2.5 107 .007 200 100 0.7 25 55.8

ORDERING INFORMATION
Qualitative Standard Filter
Circles
Catalogue no.
Diameter (mm) Grade-MS-1 Quantity/box
47 MS-1-47 100
55 MS-1-55 100
90 MS-1-90 100
110 MS-1-110 100
125 MS-1-125 100
150 MS-1-150 100

Quantitative Catalogue no.


Standard Filter
Circles
Diameter (mm) Grade-MS-40 Grade-MS-41 Grade-MS-42 Quantity/Box
47 MS-40-47 MS-41-47 MS-42-47 100
55 MS-40-55 MS-41-55 MS-42-55 100
90 MS-40-90 MS-41-90 MS-42-90 100
110 MS-40-110 MS-41-110 MS-42-110 100
125 MS-40-125 MS-41-125 MS-42-125 100
150 MS-40-150 MS-41-150 MS-42-150 100
www.microseparations.in
shivam.microseparations1992@gmail.com

Regd. Office: Plot No.121, Basement, Nyaykhand-1st


Indirapuram, Ghaziabad- 201010
Ph: 07302944016, 8433126150
Email: shivam.microseparations1992@gmail.com
, Web: www.microseparations.com