Technical Specifications

System Function G
Description Fully automated, discrete, random access clinical chemistry analyzer
Throughput Up to 400 tests/hour
Measuring Principles Spectrophotometry
Methodology End-point,Fixed-time,Kinetic,Single/Dual reagent chemistries,Mono-chromatic/Bi-chromatic,
Linear/Non-Linear multipoint calibration
Photometry System HCFG rear spectrophotometry
Optical System
Light Source 12V/20W, Quartz halogen lamp with hydro cooling system
Monochromator Grating Photometry
Wavelength 340nm,380nm,405nm,450nm,480nm,505nm,546nm,570nm,600nm,660nm,700nm,750 or 800nm
OD Linear Range 0~3.3Abs
Detector Photo-diode LED array
Reagent Handling
Reagent Probe 2, with liquid level detection and collision protection function
Reagent Volume 20ul~350ul, 0.1ul stepping
Reagent Position double reagent disk, 45x2, Continuous 5-15° C 24 hrs, 70ml & 20ml bottle
Reagent Barcode code128
Reagent Probe Carriying Rate ≤0.1%, automatci warm water cleaning
Sample Handling
Sample Volume 2ul~35ul, 0.1ul stepping
Sample Position 115, including 50 routine sample positions, 20 STAT positions, 34 Clibration positions, 8 QC positions,
3 detergent positions, Continuously cooling to keep 5-15° C 24 hrs
Sample Barcode 12of5,code128,code39,UPC/EAN,code93
Sample Probe Carriying Rate ≤ 0.1%, automatci warm water cleaning
Sample Cuvettes Specification Standard cup,original blood tube,multi-specification tube available (12-16)mm X (25-100)mm
Sample Dilution 3~170 times, Automatic

ADL/BR/Clinia+/R00-10/19 Company reserves the right to change any design and technical features of the product at any time, If needed.
Sampling Technology Liquid level detection, Collision protection, Clot detection and reverse washing
Reaction System
Reaction Rotar Rotating tray, containing 120 cuvettes (1 set 20 pieces)
Reaction Cuvette Optical diameter of 6mm
Reaction Volume 150ul-450ul
Reaction Temperature 37° C, ± 0.1° C
Reaction Disk Constant Temperature Circulating water
Mixing System Duo stirrer with triple speed mechanism
Laundry System Adopting 7 stops, 11 steps with warm water rinsing
Waste Water Treatment Two diffluence for high & low concentration waste water with concentrated waste liquid level alarming
Calibration and QC
Calibration Method Linear (one-point, two-point, multi-point), Non-linear method
Calibration Tracking Automatic description of calibration K-value trends
QC Method real time, individual, monthly
Parabola Control Rules Westgard multi-rule, L-J Chart
Operation Unit
PC Operating System Windows XP
PC Configuration CPU > 2.8 Ghz (dual core processor), Memory ≥ 1 GB; Hard-disk ≥ 160 GB
System Connection TCP/IP network connection, standard RS-232C and USB interface
Working Conditions
Power Supply VAC 220V±22V | 50/60 Hz | Power 2KVA
Ambient Temperature 10-25° C
Relative Humidity 40% - 85%
Water Consumption 25L/hour
Dimension 1060x790x1150 mm (LxWxH)
Weight Approx. 300 Kg

ISO 9001:2015 | EN ISO 13485:2016


Fully Automatic Clinical Chemistry Analyser
AGAPPE DIAGNOSTICS SWITZERLAND GmbH
Knonauerstrasse 54 - 6330 Cham, Switzerland.
Tel: +41 41 780 60 10 | Fax: +41 41 780 60 11 |info@agappeswiss.com | www.agappeswiss.com
Fully Automatic Clinical Chemistry Analyser Fully Automatic Clinical Chemistry Analyser
PRODUCT DESCRIPTION

Mispa CX4 is a fully automated random access clinical chemistry SAMPLE/REAGENT PIPETTING MECHANISM
Ÿ Trilateral Probe:- One for sample and two for
analyzer with throughput of 400 tests per hour, specially designed reagent. The probes are 60nm polished with nano
processing technology which effectively reduces
to meet uninterrupted workflow offering maximum efficacy, with
cross contamination chances. Probes are crafted
its epitome of perfection. Mispa CX4 is an ideal choice for medium with collision protection function, self-resetting,
auto re-pipetting sample and reagent
and big sized laboratories, by offering guaranteed test result Ÿ Automatic Liquid Level Detection:- The probes
accuracy, consolidated opportunities and cost savings with its are designed perfectly to detect liquid level
automatically, ensuring perfect depth and reduces
efficient platform to access wide range of chemistry and protein carryover on probe surface.
parameters. Ÿ Stand-alone syringes:- 3 stand-alone syringes,
one for sample and two for reagents. The syringes
EMPOWER YOUR LABORATORY are made of long life high-precision ceramic piston
ensures high precision of sampling.
SPEED Ÿ Intelligent CDRW facility:- Pipetting tube has
inbuilt pressure sensor to perfectly detect the clot
status. The tube contains high pressure rinsing
function to remove and clean the clot, which ensures
the pipetting volume accuracy. This process is called
CDRW “Clot Detection & Reverse Washing”.
Ÿ Water Degassing technology:- The analyzer has
special degassing device to remove the air dissolved
in the tube system for perfect pipetting.
Ÿ Probe Washing:- High pressure rinsing for internal
wall and waterfall washing for external wall, thus
THROUGHPUT ensures minimal carryover for sample disk spinning
can ensure the safety of inputting sample at any
point of time.

REFRIGERATED DOUBLE REAGENT DISKS


Ÿ Double discs with 90 positions (45 positions each),
including 2 detergent positions, 88 reagent
position. Each reagent position can
load/accommodate 70ml or 20 ml reagent bottle
Ÿ Reagent quality is secured through continuous
cooling condition of the reagent disk
Ÿ One reagent, two reagent and up to four reagents
testing (R1,R2,R3,R4) functions enable multiple
testing items to satisfy the future requirements.

MULTI-FUNCTION REFRIGERATED SAMPLE DISK


Ÿ Total 115 positions including 50 routine sample
positions, 20 STAT positions, 34 Calibration
positions, 8 QC positions, 3 detergent positions.
Ÿ QC & Calibration position maintains 5 to 15° C for
24 hours. The whole disk can be easily replaced
with handle.
Ÿ Supports various tubes and trace samples cup

PERFECTION & RELIABILITY specification


Ÿ The LED indicator for sample disk spinning can
ensure the safety of inputting sample at any point
of time.
Fully Automatic Clinical Chemistry Analyser Fully Automatic Clinical Chemistry Analyser

PROVEN HCFG PHOTOMETRY SYSTEM DUO STIRRER WITH TRIPLE SPEED MECHANISM
Ÿ Monochromator with holographic concave flat field grating (HCFG), rear Ÿ Dedicated 2 stirrer system confirms perfect mixing
spectrophotometric 12 ways parallel measuring technology, reduces Ÿ Triple speed mixing mechanism is highly efficient for latex based assays
ambient light interferences to get accurate result. Ÿ Stirrers are Teflon coated, to avoid liquid suspension and reduce cross
Ÿ Photospot technology to reach super micro analysis. contamination
Ÿ Hydro cooling method for long lamp life. Ÿ Flat paddle stirrer design with swirl rinsing offers homogeneous mixing
Ÿ Specially designed lamp placement to reduce signal attenuation and Ÿ Enhanced durability due to minimal maintenance
interference.
Ÿ 12 ways photodiode array detector, 12 ways high dynamic range
logarithmic amplifier with range of 6Abs without distortion, ensures high
concentration sample testing without data overflow.

CONSTANT TEMPERATURE REACTION CUVETTES EFFICIENT LAUNDRY SYSTEM


Ÿ Adopts a recycling water constant temperature device Ÿ Laundry system adopting 7 stops, 11 steps
Ÿ Automatically changing water and adding de-foamer Ÿ Twin dryers offer best reproducibility with minimal carryover
Ÿ Reaction cuvette is immersed into warm circulating water which heats Ÿ Vacuum draining liquid, detergent and warm water rinsing ensures
the cup evenly and condenses ambient temperature stimulus guaranteed accuracy
Ÿ PID thermostat technology to ensure temperature of 37±0.1° C Ÿ Water consumption of 25 L/hour

TIMING BEATS SPEED... PRECISION BEATS POWER...


Fully Automatic Clinical Chemistry Analyser Fully Automatic Clinical Chemistry Analyser

Duo Stirrer with


triple speed mechanism
Trilateral Hydro cooling
Probe System method

Robust Software Efficient


with multiple self laundry system
monitoring with twin
function dryers

Intelligent Dual Switch


400 Grating
CDRW Facility operation
Throughput Photometry

Proven Waterfall
HCFG System washing

EPITOME OF PERFECTION
Fully Automatic Clinical Chemistry Analyser Fully Automatic Clinical Chemistry Analyser

SEMI PERMANENT REACTION CUVETTE


Ÿ Rigid semi permanent reaction cuvette, with good
penetrating of Ultraviolet (UV), to resist against acid
– alkali solution.
Ÿ Reaction cuvettes ensures cost savings with
enhanced durability of 9 to 12 months.
REAGENT Ÿ
Ÿ
1 Set 20 Pieces | 6 Sets 120 Pieces
Cuvette optical path of 6mm.
90 Positions Ÿ On-board washing with <0.1% carry over.
Bi-Lateral Probe
Volume 20~350 Ul

SAMPLE CALIBRATION
115 Positions CALIBRATION & QUALITY CONTROL PROGRAM

3~170 Times Dilution Ÿ Linear and non-linear calibration which can be set
with time, lot number etc, with flexible calibration
Volume 2~35 Ul methods.
Ÿ 9 types of calibration curve to meet the item wise
analysis demands.
Ÿ 6 different levels of calibration for each item can be
programmed.
Ÿ Calibration tracing possibility depicting calibration K
value variation trends, help reduce system errors.
Ÿ QC with Westgard multi rules.
Ÿ QC plot with L-J and cumulative statistics.
Ÿ Automatic error reporting complaint with lab QC
management.
QUALITY CONTROL

REACTION CURVE

PERFECT INSTRUMENT FOR PRECISE RESULTS


Parameters at a Glance
Fully Automatic Clinical Chemistry Analyser Fully Automatic Clinical Chemistry Analyser

Product Code Assay Method No.of Tests Pack Size Product Code Assay Method No.of Tests Pack Size ROBUST SOFTWARE
Glucose 1 Point End 1385 5x65mL Magnesium 1 Point End 192 2x30mL Ÿ Simple, efficient and user-friendly software
Glucose Hexokinase 2 Point End 981 3x63/3x20mL CK-NAC Rate A 176 2x20/2x7mL Ÿ Real time online help system
Cholesterol 1 Point End 1385 5x65mL ASO 2 Point End 160 2x20/2x8mL Ÿ Multiple self-monitoring to ensure high data

SYSTEM SETUP
Triglycerides 1 Point End 1385 5x65mL CRP 2 Point End 230 1x50/1x20mL efficiency
HDL-C Direct 2 Point End 639 3x53/3x20mL RF 2 Point End 160 2x20/2x9mL Ÿ Multiple report formats with automatic print
LDL-C Direct 2 Point End 336 3x30/3x11mL HbA1c Direct 2 Point End 230 1x50/1x20/2X63mL function
LDH – P Rate A 338 1x65/1x20mL Microalbumin 2 Point End 144 2x20/2x6mL
Ÿ Auto re-run facility
Urea U.V 2 Point Rate 1014 3x65/3x20mL CRP Ultra 2 Point End 188 2x20/2x11mL MONITORING AND CALCULATING FUNCTION
Enzymatic creatinine 2 Point End 720 3x52/3x20mL IgA 2 Point End 160 2x20/2x8mL
Ÿ Automatic monitoring linear limit over,
Uric Acid 1 Point End 1016 4x60mL IgE 2 Point Rate 160 2x20/2x6mL reference limit over, substrate depletion etc
SGOT Rate A 981 3x63/3x20mL IgG 2 Point End 128 2x15/2x15mL Ÿ Serum index checking function, avoid
SGPT Rate A 981 3x63/3x20mL IgM 2 Point End 160 2x20/2x9mL interference from hemolytic, lipemic, icteric
Albumin 1 Point End 1108 4x65mL Lp (a) 2 Point Rate 144 2x20/2x6mL samples
Total Protein 1 Point End 418 2x50mL C3 2 Point End 136 2x19/2x5mL Ÿ C r o s s co n t a m i n a t i o n p r o g r a m , a vo i d s
Bilirubin Total TAB 2 Point End 552 3x63/3x8mL C4 2 Point End 136 2x19/2x5mL interference from different reagent
Bilirubin Driect 2 Point End 552 3x63/3x8mL Apo A1 2 Point End 150 2x20/2x5mL Ÿ Instrument analysis alarm hierarchical
Alkaline Phosphatase Rate A 981 3x63/3x20mL Apo B 2 Point End 150 2x20/2x5mL
handling for optimal job sequence priority

SAMPLE REGISTER
Ÿ System security is ensured through user
Amylase Rate A 376 2x55mL Ceruloplasmin 2 Point End 120 2x20/2x5mL
authority hierarchical management
Gamma GT Rate A 338 1x65/1x20mL Cystatin C 2 Point End 188 2x20/2x6mL
Calcium (Arsenazo ) 1 Point End 326 2x40mL Ferritin Rate A 160 2x20/2x8mL
Inorganic Phosphorus 1 Point End 554 2x65mL Prealbumin 2 Point End 132 2x20/2x4mL

Wide Range Of Biochemistry Parameters


In One Efficient Platform

CROSS CONTAMINATION PROGRAM


Offering Consolidation & Cost Savings

STEP UP TO SUPERIORITY